GENERAL INFORMATIONS

Temperature Domestic range : 30 / 70°C

Temperature Heating range : 30 / 80°C

Post-circulation :

- Heating 30”

Anti freeze :

ON 5°C - OFF 30°C ( post circulation 3’ )

Anti-sticking :

30” after 24 h

Chimeney sweeper:

15 minutes ( post circulation 3’ )

Page 6: SuperMicra 12-2003 Manuale tecnico
Page 7: SuperMicra 12-2003 Manuale tecnico
Page 8: SuperMicra 12-2003 Manuale tecnico
Page 9: SuperMicra 12-2003 Manuale tecnico
Page 10: SuperMicra 12-2003 Manuale tecnico
Page 11: SuperMicra 12-2003 Manuale tecnico
Page 12: SuperMicra 12-2003 Manuale tecnico
Page 13: SuperMicra 12-2003 Manuale tecnico
Page 14: SuperMicra 12-2003 Manuale tecnico
Page 15: SuperMicra 12-2003 Manuale tecnico
Page 16: SuperMicra 12-2003 Manuale tecnico
Page 17: SuperMicra 12-2003 Manuale tecnico

SUPERMICRA E ed SEFUNCTIONING AND FAULTS FINDING TEST

The following test must be executed with the help of the boiler’s Instructions Manual

REMARK: The lasting check must be executed with a tester on the flow of the , after disconnecting the boiler and afterdisconnecting the connector relevant to the component or circuit to be tested.

For the tests on the electrical components check the connections and the contacts of the connections even if not indicated

NO Check the 230 v net, thecable and theconnections

Move the selector on“O”

Does the green ledflash?

NO

Are there 230vbetween the clampL and N of theclamp board M 5of the main PCB? YES Replace the main PCB

YES

If flashing - Replace the NTC sensorIs the red led off? NO

If constantly on - Fill the circuit or replace the loss of water pressure switchYES

Move the selector on“SUMMER”Is the green ledconstantly on?

NO Replace the main PCB

YES

NO Check thewater network

Move the DHWselector at maximumand open an hot watertap at maximum.Is there production ofhot water?

NO Is the regulator behindthe water valveclosed?

YES Open theregulator

YES NO Replace the DHW micro switch

NO The membraneof the watervalve is dirty ordamaged

YES Clean or replace the membraneDoes the boiler switchon?

NO

Is the contact of theDHW micro-switchclosed?(electricalcontinuing between 16and 20 on the mainPCB) YES Replace the

main PCBYES

NO Replace the main PCBDoes the pump work?NO

Are there 230 vbetween the clamps ofthe pump? YES Replace the pump

YESNO Replace the pressare switch

NO With the boileroff are thecontact C andNC of the fluepressure switchclosed?

YES

Does the fan work?

( SE models only)

NO Are there 230 vbetween the clamps ofthe fan?

YES Replace the fan

Replace the main PCB if thereare not 230v between 8 and 9 ofM2, with the boiler on, if offreplace the IONO board

YES NO Replace the IONO

boardNO

Is there the spark onthe burner?

Are the ignitionelectrode and its cabledirty or damaged?

YES Clean or replaceelectrode and cable

For the SE models check thatthe contact between C and NO ofthe pressare switch is closed, thatthe pipes are connected and thepressure switch is efficient

YES

Page 18: SuperMicra 12-2003 Manuale tecnico

Replace the damaged oneNO NO REMARK: for the flue

thermostat check the draughtNO

Have the 100°Csafety thermostatand the fluethermostat (mod E)the contact closed? YES Replace the Iono board

Does the burner ignite?

During the ignitionprocess are there230 v on the of thegas valve?( reset if the boilergoes in block )

YES Replace the valve if there is no gas in the network (check ofthe pressure on the “IN” plug of the gas valve)

YES

NO Check the regulation of the power of slow ignition and of theminimum power of the gas valve (see the Manual)

Replace the main PCB

Does the flame stay inslow ignition for 8seconds?

NO

Has the power ofslow ignition beenregulated in thecorrect way? (seethe InstructionManual )

YES Is the modulatorinterrupted or inshort circuit?

NO

YES Replace the modulator

YES

NO Does the flame stayat minimum or atlow power?

SI Regulate the max power onthe gas valve, as indicated onthe manual

NE Replace the Iono board

After 8 seconds doesthe flame move to anhigher power?

NO Does the boiler goin block conditionafter 10 seconds?

YES

Is the ignitionelectrode dirty,badly regulated ordamaged? YES

Clean, regulate or replace theIONO electrode

YES

NO Does the water flowremain low? YES

Make the cleaning of theDHW exchanger withspecific products

Does the water at thetap get warm? NO

Is the water flowsuperior to thatallowed by thetype of boiler?

YES Reduce the water flow at the tap or at the regulatorYES

Reduce the water flowat the tap at about5l/min.After some secondsdoes the flamemodulate?

NO Check the NTC sensorresistance

And if necessary replace it

Value of the sensor0°C = 33 k20°C = 12,5 k60°C = 2,5 k80°C = 1,3 k

YES

END OF THE D.H.W. TEST

CHECK OF THE HEATING

NO Regulate the room thermostat

NO

Move the selector in“WINTER” with theregulation at maxim.Does the boiler startworking?

Does theroomthermostat ask forheat?

YES Make a bridge on the clamps 39 and 40 of M10 of the board: If theboiler works replace the room thermostat. If not replace the main PCB

YESNO Replace the main PCBDoes the pump start

working? NO Are the switches 5and 6 of the boardon the pump OFF? YES Regulate the switches

YES

Do the radiators getwarm?

NO Check that the eventual taps or thermostatic valvesin the system are open

YES

END OF THE TEST

Page 19: SuperMicra 12-2003 Manuale tecnico

1) Put the manometer in the outlet test point of the gas valve

2) Take the instruction manual for consultation

3) Open a DHW tap, and after 10”set the maximum pressure ( with tool number 10 )

Page 20: SuperMicra 12-2003 Manuale tecnico

4) To set the minimum

pressure (with screw driver ) after disconnecting one cable of the modulator

Page 21: SuperMicra 12-2003 Manuale tecnico

5) Regulate the slow ignition. ( left minus - right plus )

You can have 30 seconds available, if you turn the heating trimmer leftwards, till the end of the turn.

( start again the 30” with a power reset )

6) Regulate the Heating power.

At the maximun power on the rigth or at the desired power.

In order to know the values , see the instruction manual

Page 22: SuperMicra 12-2003 Manuale tecnico
Page 23: SuperMicra 12-2003 Manuale tecnico
Page 24: SuperMicra 12-2003 Manuale tecnico

Warnings for servicing

At the end of each heating period, it is necessary to check the boiler

Normally,it will be necessary to execute the following operations:

—Remove any possible oxidation from burners and electrodes—Clean the burner air passages and the exchanger—Check water and gas connections tightness—Check gas consumption at the minimum and maximum output—Verify that safety devices are correctly working—Verify periodically the good working and efficiency of the outlet duts for the combustion products —In any case of parts replacement, it is mandatory to use HERMANN original spare parts.