Sunny Island 5048 - SMA

4
SUNNY ISLAND 5048 SI 5048 Flexible • For systems from 3 kW to 300 kW • 1- and 3- phase operation, con- nectable in parallel and modularly extendable • AC and DC coupling Efficient • High efficiency • Intelligent battery management for maximum battery life • State of charge calculation Durable • Extreme overload capability • OptiCool • 5-year SMA warranty Simple • Easy commissioning with the “Quick Configuration Guide“ • Complete off-grid management SUNNY ISLAND 5048 The Island Manager Commissioning in just a few minutes: The Sunny Island 5048 can be quickly and simply prepared for operation in just a few steps. The device is flexible in its application, extendable and takes on all control processes. Its first-class battery management ensures maximum battery life. In addition, the device features an impressively high efficiency, a robust die-cast aluminum enclosure and the OptiCool active cooling system.

Transcript of Sunny Island 5048 - SMA

Page 1: Sunny Island 5048 - SMA

SUNNY ISLAND 5048 SI

504

8

Flexible •Forsystemsfrom3kWto300kW•1-and3-phaseoperation,con-

nectableinparallelandmodularlyextendable

•ACandDCcoupling

Efficient •Highefficiency•Intelligentbatterymanagementfor

maximumbatterylife•Stateofchargecalculation

Durable•Extremeoverloadcapability•OptiCool•5-yearSMAwarranty

Simple •Easycommissioningwiththe

“QuickConfigurationGuide“•Completeoff-gridmanagement

SUNNY ISLAND 5048The Island ManagerCommissioninginjustafewminutes:TheSunnyIsland5048canbequicklyandsimplypreparedforoperationinjustafewsteps.Thedeviceisflexibleinitsapplication,extendableandtakesonallcontrolprocesses.Itsfirst-classbatterymanagementensuresmaximumbattery life. Inaddition, thedevicefeaturesan impressivelyhighefficiency,arobustdie-castaluminumenclosureandtheOptiCoolactivecoolingsystem.

Page 2: Sunny Island 5048 - SMA

SUNNY ISLAND 5048

Page 3: Sunny Island 5048 - SMA

Three-phasesystem Single-phasesystem

AC output (loads)NominalACvoltage/adjustableNominalACfrequency/adjustableContinuousACpower(at25°C/at45°C)ACpowerat25°Cfor30min/1min/3sNominalACcurrent/Max.ACcurrent(peak)Totalharmonicdistortionoutputvoltage/powerfactorwithratedpowerAC input (PV array or grid)ACinputvoltage/rangeACinputfrequency/rangeMax.inputcurrent/adjustableMax.inputpowerBattery DC inputBatteryvoltage/rangeMax.batterychargingcurrent/continuouschargingcurrentat25°CBatterytype/batterycapacityChargecontrolEfficiency / self-consumptionMax.efficiencySelf-consumptionwithnoload/standbyProtectionDCreversepolarityprotection/DCfuseACshortcircuit/ACoverloadOvertemperature/excessivebatterydischargeGeneral dataDimensions(W/H/D)WeightOperatingtemperaturerangeDegreeofprotection(asperIEC60529)Features / functionOperation&display/multifunctionrelay3-phasesystems/parallelconnectionIntegratedbypass/multiclusteroperationChargelevelcalculation/fullcharge/equalizationchargeIntegratedsoftstart/PVarraysupportBatterytemperaturesensor/communicationcablesWarranty(5years)CertificatesandapprovalsAccessoriesBatterycable/batteryfuseInterface(RS485/MulticlusterPB)"GenMan"extendedPVarraystartLoad-sheddingprotection/batterycurrentmeasurement

●Standardfeatures○Optionalfeatures—notavailableTypedesignation

230V/202V–253V50Hz,60Hz/45Hz…65Hz

5000W/4000W6500W/8400W/12000W21.7A/120Aforapprox.60ms

3%/-1…+1

230V/172.5V–264.5V50Hz,60Hz/40Hz…70Hz

56A/0A…56A12.8kW

48V/41V–63V120A/100A

Lead,NiCd/100Ah…10000AhIUoUprocess

95%

25W/4W

●/●●/●●/●

467/612/235mm63kg

-25°C…+50°CIndoorinstallation(IP30)

internal/2●/●—/●

●/●/●●/●●/●●

www.SMA-Solar.com

○/○○/○○

○/○

SI5048

Technical Data Sunny Island 5048

Page 4: Sunny Island 5048 - SMA

SMA Solar Technologywww.SMA-Solar.com

SI504

8-DEN

1317

21S

MAan

dSu

nnyI

sland

arere

gister

edtrad

emarksofS

MATech

nolog

yAG.B

luetoo

th®

isaregis

tered

trad

emarksofB

luetoo

thSIG

inc..SUN

CLIX

isaregis

tered

trad

emarko

fPHO

ENIX

CONTA

CTG

mbH

&Co

.KG.T

exta

ndillustra

tionr

eflec

tthecurre

ntsta

teofth

etec

hnolo

gyatth

etim

eofpub

licati

on.S

ubjec

ttote

chnic

alch

ange

s.Nolia

bilitysh

allbeac

cepte

dforp

rintingerrors.Pr

inted

onc

hlorin

e-freepa

per.

SMA OFF-Grid COnFiGurAtOrDesign and Simulation Program for Off-Grid Systems