SUNNY ISLAND 6.0H / 8.0H for off-grID AppLIcAtIoNS
Easy to use•OptiUse:fastinstallationand commissioning,simplifiedoperation•OptiBat:stateofchargecalculation
keepsyouinformedatalltimes
robust•IP54:optimalprotectionfrom dustandhumidity•OptiCool:greatertemperature range
flexible•Forsystemsfrom3to300kW•Precisedesign•SupportsMulticlusterTechnology
•OptiPower:secureoperationinanysituation
SUNNY ISLAND 6.0H / 8.0H Simple. Robust. Flexible.Moredurablethanitspredecessors:ThenewSunnyIslandimpresseswithitshighprotectionclassandwidetemperaturerange.Moisture,dustandtemperaturefluctuationswon’timpairitsoperation,evenafter20years.ThankstoOptiCool,there’snoneedtocompromisewhenitcomestooverloadcapacityandeconomicviability.Andthere’smore:OptiPower,theintelligentloadandenergymanagementsystem,ensuresoperationevenincriticalsituations.OptiUsemakesinstallation,commission-inganddailyuseeasierthaneverwithautomaticrotaryfielddetection,anoptimizedquickconfigurationguideandintuitiveoperation.AndtheintelligentOptiBatbatterymanagementsystemautomaticallycontrolsthemostimportantcharginganddischargingprocedures,whichextendstheservicelifeofsensitiveenergystorage.SunnyIslandisatrulycomprehensivepack-ageforaworry-free,reliableandself-sufficientelectricitysupply.
SUNNY ISLAND 6.0H / 8.0H
Three-phasesystem Single-phasesystem
Sunny Island 6.0H
Sunny Island 8.0H
230V/202V...253V50Hz/45Hz...65Hz
4600W6000W/6800W/11000W
3700W20A/120A<4%/-1...+1
230V/172.5V...264.5V50Hz/40Hz...70Hz
50A11500W
48V/41V...63V110A
90A/103AFLA,VRLA/100Ah...10000AhIUoUchargeprocedurewithauto-maticfullchargeandequalization
charge.
96%<26W/<4W
●/●–/–●/●
III
467mmx612mmx242mm63kg
-25°C...+60°CI
3K6IP54
ExternalviaSRC-20/2●/●–/●
●/●/●●/●●/●
www.SMA-Solar.com●
○/○○/○
○○/○
SI6.0H-11
230V/202V...253V50Hz/45Hz...65Hz
6000W8000W/9100W/11000W
5430W26A/120A<4%/-1...+1
230V/172.5V...264.5V50Hz/40Hz...70Hz
50A11500W
48V/41V...63V140A
115A/136AFLA,VRLA/100Ah...10000Ah
IUoUchargeprocedurewithautomaticfullchargeandequalizationcharge
96%<26W/<4W
●/●–/–●/●
III
467mmx612mmx242mm63kg
-25°C...+60°CI
3K6IP54
ExternalviaSRC-20/2●/●–/●
●/●/●●/●●/●
www.SMA-Solar.com●
○/○○/○
○○/○
SI8.0H-11
Ac output (loads / stand-alone grid)Ratedgridvoltage/ACvoltagerangeRatedfrequency/frequencyrange(adjustable)Ratedpower(forUnom/fnom/25°C/cosϕ=1)ACpowerat25°Cfor30min/5min/3secACpowerat45°CRatedcurrent/maximumoutputcurrent(peak)THDoutputvoltage/powerfactorwithratedpowerAc input (pV array, grid or Mc box)Ratedinputvoltage/ACinputvoltagerangeRatedinputfrequency/allowableinputfrequencyrangeMaximumACinputcurrentMaximumACinputpowerBattery Dc inputRatedinputvoltage/DCvoltagerangeMaximumbatterychargingcurrentRatedDCchargingcurrent/DCdischargingcurrentBatterytype/batterycapacity(range)Chargecontrol
Efficiency / self-consumptionMaximumefficiencySelf-consumptionwithoutload/standbyProtective devices (equipment)ACshort-circuit/ACoverloadDCreversepolarityprotection/DCfuseOvertemperature/batterydeepdischargeOvervoltagecategoryasperIEC60664-1general dataDimensions(widthxheightxdepth)PriorityOperatingtemperaturerangeProtectionclassaccordingtoIEC62103ClimaticcategoryaccordingtoIEC60721DegreeofprotectionaccordingtoIEC60529Features / functionOperationanddisplay/multifunctionrelayThree-phasesystems/parallelconnectionIntegratedbypass/multiclusteroperationStateofchargecalculation/fullcharge/equalizationchargeIntegratedsoftstart/generatorsupportBatterytemperaturesensor/datacablesCertificatesandapprovalsWarranty:5yearsAccessoryBatterycable/batteryfuseInterfaceSI-COMSMA(RS485)/SI-SYSCAN(Multicluster)Extendedgeneratorstart“GenMan”Load-sheddingcontactor/batterycurrentmeasurement
Typedesignation
●Standardfeatures○Optionalfeatures—NotavailableDataatnominalconditions
Technical data
SMA Solar Technologywww.SMA-Australia.com.au SI_6H
_8H-DA
U140
515P
rinted
onF
SC-ce
rtified
pap
er.A
llprodu
ctsand
servi
cesd
escri
bedasw
ellastec
hnica
ldata
aresu
bject
toch
ange
,evenf
orre
ason
sofc
ountr
y-spe
cific
devia
tions,a
tany
timewitho
utno
tice.
SMAassume
snolia
bilityfo
rerro
rsoromissi
ons.Fo
rcurrent
informa
tion,
seeww
w.SM
A-So
lar.co
m
SMA off-grID coNfIgUrAtorDesign and simulation program for off-grid systems