Summary of CMS 3D pixel sensors R&D
Enver Alagoz1
On behalf of CMS 3D collaboration1Physics Department, Purdue University, West Lafayette, IN 47907-2036 US
US CMS Meeting, Colorado-Boulder, 18 May 2012
![Page 2: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/2.jpg)
• 3D vs planar• 3D sensor layouts• 3D assembly• 3D pixel sensors tests
– Lab test results– Beam test results
• Irradiation• Post-irradiation tests
– Lab test results– Beam test results
• Summary & outlook
Outline
2
![Page 3: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/3.jpg)
3D vs planar
ionizing particle
300µm
n+
p+
e
h
depletion
p-type
p+ n+
50µm
p-type
depletion
PLANAR: 3D:
• p+ and n+ electrodes are arrays of columns that penetrate into
the bulk
• Lateral depletion
• Charge collection is sideways
• Superior radiation hardness due to smaller electrode spacing: - smaller carrier drift distance - faster charge collection - less carrier trapping - lower depletion voltage
• Higher noise
• Complex, non-standard processing
3
![Page 4: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/4.jpg)
3D layouts (200 µm substrate thickness)4E Configurationn+ (readout) p+ (bias)
100
μm
150 μm
2E Configuration
1E Configuration
SIN
TEF
3D
(20
0 μ
m th
ick)
CNM
3D
(20
0 μ
m th
ick)
FBK
3D (2
00 μ
m th
ick)
Sin
gle-
side
etc
hing
Dou
ble-
side
etc
hing
Dou
ble-
side
etc
hing
4
![Page 5: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/5.jpg)
Lab test setups• Sensors bump bonded to PSI46v2 ROC in SELEX/IZM (In/PbSn bumps)• Wire bonded and assembled on FPIX plaquettes/testboards• PSI test setup is used to fully calibrate FBK sensors in lab
• ROC calibration• Noise• Charge collection with Sr-90 source
Purdue lab warm test setup Purdue cold test setup
5
![Page 6: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/6.jpg)
3D Plaquettes/testboards
SensorROC
Bump bonds
VHDIBase
plateAdhesive
Wire
bond
Bias wire SIN
TEF
3D FBK
3D
CNM
3D
6
![Page 7: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/7.jpg)
IV measurements @ 21 °C SINTEF 3D
FBK 3DCNM 3D
Breakdown voltages:
CNM > 100V
SINTEF > 100
FBK < 40V
7
![Page 8: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/8.jpg)
Noise scans @ 21 °C
Unable to measure noise at Vbias < 40V for 4E sensors from SINTEF 3D
4E2E
1E
SINTEF 3D
FBK 3D
• Planar FPIX/BPIX noise
~ 100-150 electrons• 3D sensors are
noisier 8
![Page 9: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/9.jpg)
Charge collection @ 21 °C • Sr-90 source: 1 mCi, Eβ = 0.546 ΜeV• Random trigger used
Landau convoluted Gaussian fit
1 Vcal = 65 e- MP = 14 ke-
SINTEF 3D
FBK 3D
9
FBK (200 μm thick)
![Page 10: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/10.jpg)
BEAM
CONTROL ROOM
DUT
PIXEL DETECTORS
SCINTILLATORS
3.7V POWER SUPPLY
ACELLERATOR CLOCK
CLOCK AND TRIGGER
DISTRIBUTION
FNAL testbeam• 120 GeV protons• No B field
Meson Area
10
![Page 11: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/11.jpg)
Beam test results
Telescope alignment with the Monicelli software developed by Milano Uni. collaboration
11
![Page 12: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/12.jpg)
Beam test results
Beam spot 93.4% efficiency
Unirradiated sensors
Beam spot 98.5% efficiency
CN
M 3
DV
bias
= -
15V
: 0
o til
t
FB
K 3
DV
bias
= -
15V
: 0
o til
t
12
![Page 13: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/13.jpg)
• Irradiation at the Los Alamos Neutron Science Center (LANSCE) with 800 MeV protons/cm2
– Fluences: 3.5E14, 0.7E15, and 3.5E15 neq/cm2 (FBK)
– Fluences: 0.7E15, and 3.5E15 neq/cm2 (SINTEF)
– Fluences: 1E14, 3E14, 5E14, and 0.7E15 neq/cm2 (CNM)• Post-irradiation lab (@ Purdue) and beam tests (@ FNAL)
performed for SINTEF and FBK 3D sensors– CNM sensors only tested in testbeams
• All readout chips work after irradiation– Except SINTEF case: 1 out of 6 ROCs worked
• Post-irradiation lab measurements carried out in the thermal chamber running at -20 °C – sensor temp estimated by an IR camera to be -7 °C
Irradiation
13
![Page 14: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/14.jpg)
Irradiation: IV tests @ -20 °C SINTEF 3D
FBK 3D
• SINTEF 3D breakdown improved by 15V
• FBK 3D breakdown improved by less than 10V
14
![Page 15: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/15.jpg)
Irradiation: Noise tests @ -20 °C SINTEF 3D
FBK 3D
• SINTEF 3D noise degraded by less than 50 electrons
• FBK 3D noise degraded by less than 50 electrons
15
![Page 16: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/16.jpg)
Irradiation: Charge collection @ -20 °C
Signal LOSS in FBK 3D (@ -30V):
1E 43% after 1E15 p/cm2 (0.7E15 neq/cm2)1E 50% after 5E15 p/cm2 (3.5E15 neq/cm2)
2E 14% after 1E15 p/cm2 (0.7E15 neq/cm2)4E 14% after 1E15 p/cm2 (0.7E15 neq/cm2)SINTEF (200 μm thick)
FBK (200 μm thick)
• Sr-90 source: 1 mCi, Eβ = 0.546 ΜeV• Random trigger used
16
![Page 17: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/17.jpg)
Irradiation: Beam test resultsC
NM
(@
-80
V)
FB
K (
@ -
30V
)S
INT
EF
(@
-80
V)
p+
n+
1E
2Ep+
n+
4E p+
n+
• electrodes are less sensitive: observed lower efficiency on electrode regions
17
![Page 18: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/18.jpg)
Summary & outlook
• 3D sensors have several features outperform planar sensors• Sensors received from SINTEF (Norway), FBK (Ital), and CNM (Spain)-Lab characterization tests done at Purdue• Breakdown voltage: SINTEF > 100V, CNM > 100V, and FBK < 40V• 3D sensors have higher noises vs CMS planar sensorsTestbeams carried at FNAL • All efficiencies are higher than 90%Irradiation performed at Los Alamos (800 MeV protons/cm2)• Irradiated fluences are between 1E14 and 3.5x1015 neq/cm2
• Signal loss in FBK 3Ds is lower (14%) for sensors with more than 1 electrodes
Next:• Expecting 3Ds from SINTEF without support wafer• Expecting 3Ds with 1E,2E, and 4E configurations from CNM• Next irradiation fluences will go up to 1E16 neq/cm2
18
![Page 19: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/19.jpg)
Czech Technical University, Fermilab, Purdue University, INFN Turin, SINTEF, SLAC, University of Hawaii, University of Manchester
3DC
19
![Page 20: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/20.jpg)
BACKUP SLIDES
20
![Page 21: Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN 47907-2036.](https://reader035.fdocuments.in/reader035/viewer/2022062717/56649e455503460f94b39fbc/html5/thumbnails/21.jpg)
Noise tests @ 21 °C Single pixel SCurve
2D noise map
Noise distributionError function fit
Gaussian fit
Higher noise due to long pixel on the sensor edges
Noise measurement of FBK 1E type 3D sensor
21