Suggested mounting instruction

24
SPIDERS :: 3.02 Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected] SUMMARY Pages 3.03 >> 3.25 SPIDERS :: SPIDERS Casted stainless steel spider Ref: S3000 > Page 3.05 Ref: S3001 > Page 3.07 Ref: S3006 > Page 3.09 Casted aluminium spider Ref: S3007 > Page 3.11 Laser cut spider Ref: S3003 > Page 3.13 Casted stainless steel spider, with plate Ref: S3100 > Page 3.15 Ref: S3101 > Page 3.17 Accessories Page 3.19 Suggested mounting instructions Page 3.21 4 steps to order your spiders Page 3.23 Order form Page 3.25

Transcript of Suggested mounting instruction

Page 1: Suggested mounting instruction

SPIDERS ::

3.02Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SU

MM

AR

Y

Pages 3.03 >> 3.25

SPIDERS ::S

PID

ER

S

Casted stainless steel spiderRef: S3000 > Page 3.05 Ref: S3001 > Page 3.07Ref: S3006 > Page 3.09

Casted aluminium spiderRef: S3007 > Page 3.11

Laser cut spiderRef: S3003 > Page 3.13

Casted stainless steel spider, with plateRef: S3100 > Page 3.15Ref: S3101 > Page 3.17

AccessoriesPage 3.19

Suggested mounting instructionsPage 3.21

4 steps to order your spidersPage 3.23

Order formPage 3.25

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:20 Page 1

Page 2: Suggested mounting instruction

SPIDERS ::

3.03Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

Specification sheet spiders: Original texts from « cahier 3574 du CSTB »

The technique:

In order to obtain a cor-rect adjustment of thespider, it is recommen-ded to use an interme-diary part, the “Omega”.

This part allows a bi-directional adjustment. The central slotted hole has

to be imperatively oriented horizontally, so that the supportedweight does not cause the spiderto slide down.

The glass panels are either supported or suspended. Every glassis generally held by two carrying points (supporting the weight)

allowing horizontal movements due to dilatation…

FIXED POINT Ø 17 mm

SLOTTED POINT Ø 17 x 24 mm

FREE POINT Ø 24 mm

FREE POINT Ø 24 mm

Whichever technical dispositions areadopted for the realization of the functio-nal clearances, those ones have toremain operational with the time (no sei-zing, buttressing, jamming or uncontrol-led tightening…). This can be obtainedfor example by the use of spacers.

… The other fixing points have to allow movements in alldirections in the plane of the glass.

The spider plays the role of intermediary between the carrying structure and the fittings fixed onto the glass panel.The fineness of its lines allows the construction to retain all its transparency.

3.1.4 Functional clearancesThe anticipated functional clearances of the spiders as well as the point fittings have to allow the glass to move towards their fixing pointswithout creating any stress in the plane of the glass or embedding moments under:- the effects of the wind or snow loads (shortening of the distance between glass holes and deformation of the structure)- the differential thermal dilatations between the structure and the glasses- the differential displacements of the spiders

The fixing of the spiders on the façade:

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:20 Page 2

Page 3: Suggested mounting instruction

SPIDERS ::

3.04Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

1 mm0,1 mm0

ULS

daN(lb)

SLS

The anti-rotation of the spider:

The layout of the spiders on the façade:

3.1.3 To avoid the risk of displacement of the spiders under the weight of the glasses during installation or in case of accidental glass breakage, the spiders have to be locked in rotation by any appropriate means (for example: use of high resistance bolts under controlled tightening, elasticand cotter pins etc.).

Each SADEV spider is delivered in accordance to its position on the façade.In order to facilitate the orientation of the different positions, we’ve classified them in several mounting instructions that cover all scenarios.For all requests, it’s sufficient for you to give us the inventory of your different positions. For example: 56 specimens of S3000 – 5.

For more information please find the page “How to order your spiders?” at the end of this chapter.

1 - In case of glass breakage, the spider is drag-ged in rotation by the remaining glass panel.It’s from this point that the pins maintain thespider in position.

2 - All spiders positioned at the border of thefaçade are dragged in rotation by the glasspanels. The pins maintain continuously thespiders in position.

1 14 3

3

16 5 5 17

16 7 8 17

16 9 10 17

16 7 8 17

16 6 4 17

11 11

14

5

5

5

5

5

12 13 13

14

01-THE STUDY 02-THE IDENTIFICATION

S3000 POSITION 3

3

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:20 Page 3

Page 4: Suggested mounting instruction

SPIDERS ::

3.05Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3000 MONTI® Designation : casted stainless steel spider.

AS

S E S M ENT

TECHNICAL

Dimensions:

Material: AISI 316 – Surface finish: dull polished GR400

Technical assessmentavailable online atwww.sadev.com

Glass side view

SP

IDE

RS

Glass side view

REG

IS

TERED

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 4

Page 5: Suggested mounting instruction

SPIDERS ::

3.06Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Modèle : S3000 MONTI®

The drilling diameter for the pins is 6 mm. Do not drill the holes for the pins in your structure before mounting the spiders. To fix the spider on your structure the“Omega” (see accessories) is highly recommended to adjust the spider’s position. The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply).This bolt shall not be fitted into a vertical slotted holes due to the risk of slipping (under the weight), the pins are not designed to hold any permanent loads (cf. speci-fication sheet). The spider has to be positioned on a flat support. The slotted holes Ø 17x24 mm and free holes Ø 24 mm in the spider are not to be used to adjustthe spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized forM14 fittings (FXR, FXV); other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

Load perpendicular to glass (per arm)

SLS* at 1 mm ULS*238 daN 300 daN(535 lb) (674 lb)

Load parallel to glass(per arm)

SLS* at 1 mm ULS*434 daN 398 daN(975 lb) (894 lb)

1 arm 180°

2 arms 180°Weight: 1,1 kg

Weight: 1,41 kg

Weight: 2 kg

Weight: 0,71 kg Weight: 0,89 kg

Weight: 2,6 kg

1 arm 90°

2 arms 90°

4 arms

3 arms

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 5

Page 6: Suggested mounting instruction

SPIDERS ::

3.07Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3001 Designation : casted stainless steel spider

AS

S E S M ENT

TECHNICAL

Dimensions:

Material: AISI 316 – Surface finish: electro polished

Technical assessmentavailable online atwww.sadev.com

Glass side view

SP

IDE

RS

Glass side view

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 6

Page 7: Suggested mounting instruction

SPIDERS ::

3.08Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3001

The drilling diameter for the pins is 6 mm. Do not drill the holes for the pins in your structure before mounting the spiders. To fix the spider on your structure the“Omega” (see accessories) is highly recommended to adjust the spider’s position. The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply).This bolt shall not be fitted into a vertical slotted holes due to the risk of slipping (under the weight), the pins are not designed to hold any permanent loads (cf. speci-fication sheet). The spider has to be positioned on a flat support. The slotted holes Ø 17x24 mm and free holes Ø 24 mm in the spider are not to be used to adjustthe spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized forM14 fittings (FXR, FXV); other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

Load perpendicular to glass (per arm)

SLS* at 1 mm ULS*110 daN 155 daN(247 lb) (348 lb)

Load parallel to glass(per arm)

SLS* at 1 mm ULS*257 daN 241 daN(577 lb) (541 lb)

1 arms 180°

2 arms 180°

1 arm 90°

2 arms 90°

4 arms

3 arms

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

Weight: 0,58 kg

Weight: 0,8 kg

Weight: 1,06 kg

Weight: 0,41 kg Weight: 0,49 kg

Weight: 1,52 kg

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 7

Page 8: Suggested mounting instruction

SPIDERS ::

3.09Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3006 VERTECH Designation : casted stainless steel spider.

Dimensions:

Material: AISI 316 – Surface finish: dull polished GR400

Glass side view

SP

IDE

RS

Glass side view

REG

IS

TERED

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 8

Page 9: Suggested mounting instruction

SPIDERS ::

3.10Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3006 VERTECH

The drilling diameter for the pins is 6 mm. Do not drill the holes for the pins in your structure before mounting the spiders. To fix the spider on your structure the“Omega” (see accessories) is highly recommended to adjust the spider’s position. The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply).This bolt shall not be fitted into a vertical slotted holes due to the risk of slipping (under the weight), the pins are not designed to hold any permanent loads (cf. speci-fication sheet). The spider has to be positioned on a flat support. The slotted holes Ø 17x24 mm and free holes Ø 24 mm in the spider are not to be used to adjustthe spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized forM14 fittings (FXR, FXV); other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

1 arm 180°

2 arms 180°

1 arm 90°

2 arms 90°

4 arms

3 arms

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

Weight: 0,94 kg

Weight: 1,20 kgWeight: 1,62 kg

Weight: 0,62 kg Weight: 0,78 kg

Weight: 2,14 kg

Load perpendicular to glass (per arm)

SLS* at 1 mm ULS*No tests No testsavailable available

Load parallel to glass(per arm)

SLS* at 1 mm ULS*No tests No testsavailable available

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 9

Page 10: Suggested mounting instruction

SPIDERS ::

3.11Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3007 Designation : casted aluminium spider.

AS

S E S M ENT

TECHNICAL

Dimensions:

Material: AI Si 5 Mg – Surface finish: Sanded

Technical assessmentavailable online atwww.sadev.com

Glass side view

SP

IDE

RS

Glass side view

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 10

Page 11: Suggested mounting instruction

SPIDERS ::

3.12Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3007

The drilling diameter for the pins is 6 mm. Do not drill the holes for the pins in your structure before mounting the spiders. To fix the spider on your structure the“Omega” (see accessories) is highly recommended to adjust the spider’s position. The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply).This bolt shall not be fitted into a vertical slotted holes due to the risk of slipping (under the weight), the pins are not designed to hold any permanent loads (cf. speci-fication sheet). The spider has to be positioned on a flat support. The slotted holes Ø 17x24 mm and free holes Ø 24 mm in the spider are not to be used to adjustthe spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized forM14 fittings (FXR, FXV); other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

1 arm 180°

2 arms 180°

1 arm 90°

2 arms 90°

4 arms

3 arms

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

Weight: 0,58 kg

Weight: 0,68 kg

Weight: 0,8 kg

Weight: 0,38 kg Weight: 0,48 kg

Weight: 1,1 kg

Load perpendicular to glass (per arm)

SLS* at 1 mm ULS*182 daN 198 daN(409 lb) (445 lb)

Load parallel to glass(per arm)

SLS* at 1 mm ULS*235 daN 199 daN(528 lb) (447 lb)

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 11

Page 12: Suggested mounting instruction

SPIDERS ::

3.13Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3003 Designation : laser cut spider.

AS

S E S M ENT

TECHNICAL

Dimensions:

Material: AISI 316L – Surface finish: dull polished GR220Material: E36 / Epoxy painting, polished zinc undercoat Thickness: E= 8 mm, 10 mm, 12 mm, 14 mm, 16 mm.

Technical assessmentavailable online atwww.sadev.com

Glass side view

SP

IDE

RS

Glass side view

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 12

Page 13: Suggested mounting instruction

SPIDERS ::

3.14Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3003

The drilling diameter for the pins is 6 mm. Do not drill the holes for the pins in your structure before mounting the spiders. To fix the spider on your structure the“Omega” (see accessories) is highly recommended to adjust the spider’s position. The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply).This bolt shall not be fitted into a vertical slotted holes due to the risk of slipping (under the weight), the pins are not designed to hold any permanent loads (cf. speci-fication sheet). The spider has to be positioned on a flat support. The slotted holes Ø 17x24 mm and free holes Ø 24 mm in the spider are not to be used to adjustthe spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized forM14 fittings (FXR, FXV); other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

1 arm 180°

2 arms 180°

1 arm 90°

2 arms 90°

4 arms

3 arms

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

Ep. 10 mm = Weight: 1,04 kg

Ep. 10 mm = Weight: 1,4 kgEp. 10 mm =

Weight: 1,86 kg

Ep. 10 mm = Weight: 0,76 kgEp. 10 mm = Weight: 0,90 kg

Ep. 10 mm = Weight: 2,32 kg

Load perpendicular to glass (per arm Ep. 10 mm)

SLS* at 1 mm ULS*85 daN 136 daN(191 lb) (305 lb)

Load parallel to glass(per arm Ep. 10 mm)

SLS* at 1 mm ULS*1077 daN 820 daN(2421 lb) (1843 lb)

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:21 Page 13

Page 14: Suggested mounting instruction

SPIDERS ::

3.15Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3100 MONTI® Designation : casted stainless steel spider, with plate.

AS

S E S M ENT

TECHNICAL

Dimensions:

Material: AISI 316 – Surface finish: dull polished GR400

Technical assessmentavailable online atwww.sadev.com

SP

IDE

RS

Glass side view

Glass side view

REG

IS

TERED

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 14

Page 15: Suggested mounting instruction

SPIDERS ::

3.16Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3100 MONTI®

The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply). The slotted holes Ø 17 x 24 mm and free holes Ø 24 mm in the spider are not to beused to adjust the spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized for M14 fittings (FXR, FXV). Other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

2 arms

1 arm 90°right

1 arm 90°left

1 arm 180°

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

Weight: 2,18 kg

Weight: 1,06 kg

Weight: 1,59 kg Weight: 1,59 kg

Load perpendicular to glass (per arm)

SLS* at 1 mm ULS*195 daN 184 daN(438 lb) (413 lb)

Load parallel to glass(per arm)

SLS* at 1 mm ULS*542 daN 410 daN(1218 lb) (921 lb)

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 15

Page 16: Suggested mounting instruction

SPIDERS ::

3.17Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3101 Designation : casted stainless steel spider, with plate.

AS

S E S M ENT

TECHNICAL

Dimensions:

Material: AISI 316 – Surface finish: electro polished

Technical assessmentavailable online atwww.sadev.com

SP

IDE

RS

Glass side view

Glass side view

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 16

Page 17: Suggested mounting instruction

SPIDERS ::

3.18Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: S3101

The fixing of the spider is done with a M16 or a M12 bolt (out of Sadev supply). The slotted holes Ø 17 x 24 mm and free holes Ø 24 mm in the spider are not to beused to adjust the spider! They are needed to absorb the manufacturing tolerances and the thermal deformation of the glass and of the structure.The spiders are standardized for M14 fittings (FXR, FXV). Other diameters are available on request.

SADEV recommends using thread locking compound, except in case of specific mounting constraints.

Mechanical performances:

Configuration:

Suggested mounting instruction:

*SLS: Serviceability Limit State (load causing a deformation of 1 mm)ULS: Ultimate Limit State: Elastic limit Rp0.1 (maximal load causing a permanent

deformation of the spider of 0,1 mm).

Represents a fixed point Ø 17 mm, a slotted point Ø 17x24 mm, or a freepoint Ø 24 mm depending on the position of the spider on the façade (seesuggested mounting instructions at the end of the chapter).

SP

IDE

RS

Glass side view

1 mm0,1 mm0

ULS

daN(lb)

SLS

2 arms

1 arm 90°right

1 arm 90°left

1 arm 180°

Weight: 1,46 kg

Weight: 0,79 kg

Weight: 1,1 kg Weight: 1,1 kg

Load perpendicular to glass (per arm)

SLS* at 1 mm ULS*128 daN 128 daN(287 lb) (287 lb)

Load parallel to glass(per arm)

SLS* at 1 mm ULS*457 daN 497 daN(1027 lb) (1117 lb)

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 17

Page 18: Suggested mounting instruction

SPIDERS ::

3.19Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

Reference: BENDED OMEGA Designation: bended omega for vertical mounting:

SP

IDE

RS

Adjustment (1)of +/- 5 mm horizontally and vertically

Vertical use COMPULSORY

Reference for spiders S3000, S3001, S3003, S3007:

OMÉGA-IN12V AISI 316L Stainless steel model dull polishedOMÉGA-IN12V-R Painted AISI 316L Stainless steel model with

your needed RAL-colour

Designation : fastenings kit for bended:

Kit for S3000 spiders.

KIT-OM-VIS-S30001 – M12 bolt2 – Washer for M123 – Insert (S3000 only)4 – Spring washer5 – M12 nut

Kit for S3001, S3003 and S3007 spiders.

KIT-OM-VIS-S3001371 – M12 bolt2 – Washer for M124 – Spring washer5 – M12 nut

1 – Omega2 – M12 H bolt3 – Anti-rotation plate4 – Washer for M125 – Spring washer6 - M12 nut

Reference: CASTED STAINLESS STEEL OMEGA

Designation: casted omega kit for S3006 spider for vertical mounting:

Vertical use COMPULSORY

Reference

S3000-OMEGA-R AISI 316 Stainless steel model for S3006 Vertech spider. Finish dull polished GR400

Registered

REG

IS

TERED

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 18

Page 19: Suggested mounting instruction

SPIDERS ::

3.20Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

Stainless steel elastic pin:

Stainless steel spacer:

Special drill for stainless steel:

The spacer is compulsory in order to allow the free displacement of the fitting towards the spider. One spacer per spider’s arm (or per fitting) are needed.

The pin is compulsory in order to lock the spider in rotation towards the structure. Two pins per spider are needed +5 %.

Designation: Reference:

Pin for S3000, S3001, S3006, S3003 D1481A2-6-36Pin for S3007 D1481A2-6-60

Special drill for stainless steel. Diameter 6 mm.

Référence :

09 90 01 60

Designation Diameter of the fitting Reference

spacer for S3000, S3001, S3006, S3100, S3101, S3003 thickness 12 M12 ENT-12-16,5-12,5

spacer for S3003 thickness 8 M12 ENT-12-16,5-8,5

spacer for S3003 thickness 10 M12 ENT-12-16,5-10,5

spacer for S3003 thickness 15 M12 ENT-12-16,5-15,5

spacer for S3007 M12 ENT-12-16,5-21,5

spacer for S3000, S3001, S3006, S3100, S3101, S3003 thickness 12 M14 ENT-14-16,5-14,5

spacer for S3003 thickness 8 M14 ENT-14-16,5-8,5

spacer for S3003 thickness 10 M14 ENT-14-16,5-10,5

spacer for S3003 thickness 15 M14 ENT-14-16,5-15,5

spacer for S3007 M14 ENT-14-16,5-21,5

spacer for S3000, S3001, S3006, S3100, S3101, S3003 thickness 12 M16 ENT-16-18,5-18,5

spacer for S3003 thickness 8 M16 ENT-16-18,5-8,5

spacer for S3003 thickness 10 M16 ENT-16-18,5-10,5

spacer for S3003 thickness 15 M16 ENT-16-18,5-15,5

spacer for S3007 M16 ENT-16-18,5-21,5

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 19

Page 20: Suggested mounting instruction

SPIDERS ::

3.21Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

Suggested mounting instruction:

Montage - A Montage - B

1 2 3

4 5 5 6

4 7 8 6

4 9 10 6

4 7 8 6

4 6 4 6

11 13

2

5

5

5

5

5

12 11 13

2

Montage - C Montage - D

19 24

23 26

19 24

23 26

19 24

23

19

23

19

23

19

23

26

19 24

23 26

19 24

23 26

19 24

23

25

23

25

23

25

23

25

23

25

23

25

2326

24

26

24

26

25

23

24

26

25

23

25

23

24

26

24

26

24

26

1 14 3

16 5 5 17

16 7 8 17

16 9 10 17

16 7 8 17

16 6 4 17

11 11

14

5

5

5

5

5

12 13 13

14

19

21

21

21

21

21

23

20

22

22

22

22

22

23

19

21

21

21

21

21

23

20

22

22

22

22

22

23

19

21

23

23

20

19 20

22

23

23

19

21

21

21

21

21

23

20

22

22

22

22

22

23

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 10/02/10 14:06 Page 20

Page 21: Suggested mounting instruction

SPIDERS ::

3.22Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

1 mm0,1 mm0

ELU

daN

ELS

Montage - E Montage - F

1 3 3 3 31 1 1

11 13

12

13 1311 11

4 6 6 6 64 4 4

4 6 6 13 64 11 4

4 6 6 3 64 1 4

4 6 6 13 64 11 4

4 6 6 64 4

1 2 2 2 3B

3 3 31 1 1

13 13

12

13 1111 11

16 6 6 6 174 4 4

16 6 6 13 174 11 4

16 6 6 3 174 1 4

16 6 6 13 174 11 4

16 6 6 174 4

1sym 3sym

Montage - G Montage - H

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 25

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

19 20

23 23

Suggested mounting instructions for plate spiders:

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:22 Page 21

Page 22: Suggested mounting instruction

SPIDERS ::

3.23Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

4 steps to order your spiders:

Considering the mechanical performances and the esthetical design you’ve chosen – for example - the S3000 spider. With thehelp of the spider’s drawings available on SADEV’s web site www.sadev.com, you design your façade. At this stage you placethe different spiders (4 arms, 2 arms etc.) using the symbol O. You can already get inspired by the mounting instructions availa-ble at the end of this chapter.

Once the façade is designed, you have to identify “the position” of the spider so that SADEV can deliver the right spider with the cor-rect configuration of the holes Ø 17 mm, Ø 17 x 24 mm and Ø 24 mm. Therefore, get the mounting proposition(s) corresponding toyour façade and mark the position numbers on your drawing.

01-THE STUDY 02-THE IDENTIFICATION 03-THE ORDER 04-THE DELIVERY

S3000 POSITION 3 S3000-3

x33

01-THE STUDY

S3000

02-THE IDENTIFICATION

POSITION 3

3

1 14 3

3

16 5 5 17

16 7 8 17

16 9 10 17

16 7 8 17

16 6 4 17

11 11

14

5

5

5

5

5

12 13 13

14

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:23 Page 22

Page 23: Suggested mounting instruction

SPIDERS ::

3.24Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

03-THE ORDER

S3000-3

x3

04-THE DELIVERY

All your spiders are now identified; sample the different spider quantities by position in the order form (end of the chapter).

The spiders will be delivered packed in cardboard boxes and referenced by position. Do not forget to furnish the montage team with the mounting drawings of your facade on which the mounting positions are indicated.

S3000-3 S3000-14 S3000-5 S3000-16 S3000-1 S3000-17

x3

x9

x9 x3 x9x27

REFERENCE POSITION QTY PRICE

S3000 5 27 S3000 17 9 S3000 16 9 S3000 14 9 S3000 1 3 S3000 3 3

Oméga-in 12 v ---

60 D1481 a2-6-36 120ENT-14-16,5-14,5 168

Mounting suggestions: A, B, C, D, E, F, G, H.

Fittings diameter (FXR, FXV) : M12, M14, M16, autre : ………

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:23 Page 23

Page 24: Suggested mounting instruction

SPIDERS ::

3.25Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 www.sadev.com - [email protected]

SP

IDE

RS

TOTAL

REFERENCE POSITION QTY PRICE

Project name Your phone number: DISCOUNT

Your fax:

Customer name: Interlocutor: Date:

Order form for spider

Price request

Order

Mounting suggestions: A, B, C, D, E, F, G, H.

Fittings diameter (FXR, FXV): M12, M14, M16, Others : ………

chap_03-ATTACHES-cat-classic-gb:Mise en page 1 25/11/09 21:23 Page 24