P-SERIES Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. Job Name: System Reference: Date: Indoor Unit: PLA-A30BA4 SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 30,000 BTU/H CEILING-CASSETTE HYPER HEAT-PUMP SYSTEM ACCESSORIES Indoor Unit Multi-function Casement (PAC-SH53TM-E) Air Outlet Shutter Plates (PAC-SH51SP-E) □ High-efficiency [MERV 10] Filter (PAC-SH59KF; req. PAC-SH53TM) Outdoor Unit M-NET Adapter (PAC-SF80MA-E) Wind Baffle (One Piece)* (WB-PA2) Air Outlet Guide (One Piece)* (PAC-SG59SG) *PUY(Z) requires two outlet guides or wind baffles for installation. GENERAL FEATURES High heating capacity at low outside temperatures Exhibits 100% of rated heating capacity at 5º F; 90% of rated heating capacity at -4º F Built-in drain lift mechanism for condensate removal; lifts up to 33-7/16 inches Wide air flow pattern for better air distribution; independently adjustable vanes Auto wave airflow in heating mode—unit independently cycles through horizontal and vertical positions for a more even heat distribution Self-check function—integrated diagnostics Limited warranty: five years parts and seven years compressors Controller Options Wireless Wall-mounted Remote Controller Kit (MHK1)** Portable Central Controller (MCCH1)** Outdoor Air Sensor (MOS1)** Wired Wall-mounted Controller (PAR-31MAA)** Simple MA Remote Controller (PAC-YT53CRAU)** **See Submittal for information on each option. M-NET Adapter (PAC-SF81MA) i-see Sensor Corner Panel (PAC-SA1ME-E) Hand-held Wireless Remote Controller (PAR-FL32MA; req. PAR-FA32MA-E) Wireless Signal Receiver Module (PAR-FA32MA-E) Outdoor Unit: PUZ-HA30NHA4

Transcript of SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4-BS...SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 ... GENERAL...

Page 1: SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4-BS...SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 ... GENERAL FEATURES ... Specifications are subject to change without notice.

P-SERIES

Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.

Job Name:System Reference: Date:

Indoor Unit: PLA-A30BA4

SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 30,000 BTU/H CEILING-CASSETTE HYPER HEAT-PUMP SYSTEM

ACCESSORIES Indoor Unit

□ Multi-function Casement (PAC-SH53TM-E) □ Air Outlet Shutter Plates (PAC-SH51SP-E)

□ High-efficiency [MERV 10] Filter (PAC-SH59KF; req. PAC-SH53TM)

Outdoor Unit □ M-NET Adapter (PAC-SF80MA-E) □ Wind Baffle (One Piece)* (WB-PA2) □ Air Outlet Guide (One Piece)* (PAC-SG59SG)

*PUY(Z) requires two outlet guides or wind baffles for installation.

GENERAL FEATURES• High heating capacity at low outside temperatures• Exhibits 100% of rated heating capacity at 5º F; 90% of rated heating capacity at -4º F• Built-in drain lift mechanism for condensate removal; lifts up to 33-7/16 inches• Wide air flow pattern for better air distribution; independently adjustable vanes• Auto wave airflow in heating mode—unit independently cycles through horizontal and vertical positions for a more even heat distribution• Self-check function—integrated diagnostics• Limited warranty: five years parts and seven years compressors

Controller Options □ Wireless Wall-mounted Remote Controller Kit (MHK1)** □ Portable Central Controller (MCCH1)** □ Outdoor Air Sensor (MOS1)** □ Wired Wall-mounted Controller (PAR-31MAA)** □ Simple MA Remote Controller (PAC-YT53CRAU)**

**See Submittal for information on each option. □ M-NET Adapter (PAC-SF81MA) □ i-see Sensor Corner Panel (PAC-SA1ME-E) □ Hand-held Wireless Remote Controller (PAR-FL32MA; req. PAR-FA32MA-E) □ Wireless Signal Receiver Module (PAR-FA32MA-E)

Outdoor Unit: PUZ-HA30NHA4

Page 2: SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4-BS...SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 ... GENERAL FEATURES ... Specifications are subject to change without notice.

Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.

SPECIFICATIONS: PLA-A30BA4 & PUZ-HA30NHA4

Electrical RequirementsPower Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 HzBreaker Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 AVoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . .DC ±24VIndoor - Remote Controller . . . . . . . . . . . . . . . . . . . . . MKH1 DC 3V

PAR-21MAAU DC 12VPAR-FL32MA DC 3V

OPERATING RANGEIndoor Intake Air Temp. Outdoor Intake Air Temp.

CoolingMaximum 90º F (32º C) DB

73º F (23º C) WB 115º F (46º C) DB

Minimum 66º F (19º C) DB 59º F (15º C) WB 0º F** (-18º C) DB

HeatingMaximum 83º F (28º C) DB 70º F (21º C) DB

59º F (15º C) WB

Minimum 63º F (17º C) DB -13º F (-25º C) DB -13º F (-25º C) WB

Note: With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23º F (-5º C) DB.

CoolingRated Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .18,000 Btu/hSEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15.6 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2,450 W

Heating at 47°FRated Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .18,000 Btu/hHSPF (IV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.4 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3,440 WHeating at 17°FRated Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19,000 Btu/hRated Total Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2,710 WMaximum Capacity** . . . . . . . . . . . . . . . . . . . . . . . . . .32,000 Btu/hTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..5,720 W

Heating at 5°FMaximum Capacity** . . . . . . . . . . . . . . . . . . . . . . . . . .32,000 Btu/hTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6,630 W

Indoor UnitMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Fan Motor (ECM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.51 F.L.A.Fan Motor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 WAirflow (Lo - M1 - M2 - Hi) . . . . . . . 490 - 570 - 640 - 740 Dry CFM 460 - 530 - 600 - 710 Wet CFMSound Pressure Level (Lo - M1 - M2 - Hi) . . 28 - 30 - 32 - 34 dB(A)DIMENSIONS UNIT INCHES / MM PANEL INCHES / MMW 33-1/16 / 840 37-3/8 / 950D 33-1/16 / 840 37-3/8 / 950H 10-3/16 / 258 1-3/8 / 35

Weight (Unit/Grille) lbs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 / 13 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 / 6External Finish . . . . . . . . . . . . . . . . . . . . . Munsell No. 6.4 8.9 / 0.4Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4" / 32 mmOutdoor UnitCompressor . . . . . . . . . . . . . . . . . . . . . . . DC Inverter-driven ScrollMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28Fan Motor (ECM) . . . . . . . . . . . . . . . . . . . . . . . . . . .0.4 + 0.4 F.L.A.Sound Pressure LevelCooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 dB(A)Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 dB(A)DIMENSIONS INCHES / MMW 37-3/8 / 950D 13 + 1-3/16 / 330 + 30H 53-1/8 / 1,350

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265 lbs. / 120 kgExternal Finish . . . . . . . . . . . . . . . . . . . . . .Munsell No. 3Y 7.8 / 1.1Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8" / 15.88 mm Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mmMax. Refrigerant Pipe Length. . . . . . . . . . . . . . . . . . . . . 245' / 75 mMax. Refrigerant Pipe Height Difference . . . . . . . . . . . . 100' / 30 mConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flared

* Rating Conditions per AHRI Standard Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WBHeating at 47º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47º F | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WBHeating at 5º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 5º F | Outdoor: 5º F (-15º C) DB / 5º F (-15º C) WB

** Maximum Capacity is at full speed and performance for INVERTER-driven System.

Notes:

Page 3: SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4-BS...SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 ... GENERAL FEATURES ... Specifications are subject to change without notice.

Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.

DIMENSIONS: PLA-A30BA4

Unit : inch(mm)

14-27/3211-3/162-3/8+5 0

(7.5

)

+35

-5

(160)

(500

)

(950

)

Floor

Min.94-1/2(2400)from floor

Entireperiphery

(36)(83)

(83)

(36) (500)

(950)

(597

)

(597)

( 1

58)

( 175)(350)

( 150)

(14- 2.8)

(167

)(1

55)

(130

)(1

00)(90) (90)

(100) (100)

(35)

(17

)

+3/1

60

(190

)

(156

)(1

05)

(50~

70)

(140

)

(170

)

(377)(284)(60)

(24)

(187.5)(840)

(160)

(160

)

(20~

45)

to 1

-25/

32(8

60~9

10)

(620

)

(605

)-3

/16

+1-3

/8

(90)

(150

)(1

60)

(7.5

)

(20~

45)

1-25

/32

Corner pocket

In case of IR wireless remote controllerIn case of standard grille

Note1. As for drain pipe, please use VP-25(O.D. 1-1/4( 32) PVC TUBE). Drain pump is included. Max. liftng height is 70-7/18(850mm) from the ceiling. 2. As for suspension bolt, please use M10 or W3/8.(Procured at local site) 3. Electrical box may be removed for the service purpose. Make sure to slack the electrical wire little bit for control/power wires connection. 4. The height of the indoor unit is able to be adjusted with the grille attached. 5. For the installation of the optional high efficiency filter or optional multi-functional casement. 1) Add 5-5/16(135mm) to the dimensions marked on the figure. 2) The optional high efficiency filter must be used jointly with the multi-functional casement. 6. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. (It becomes the cause of dew drops/water dew.) 7. As for necessary installation/service space, please refer to the left figure.

Drain holeDrain pump clean holeand Drain emergency drainage hole

For MA-Remote controllerterminal block

Emergency operation switch<Cooling>Emergency operation switch<Heating>

Indoor unit

Ceiling

Cut out hole

Burring hole pitch3- 1/8(3- 2.8)Burring hole

Detail drawing of fresh air intake hole

Burring hole14- 1/8

Cut out hole

Burring hole pitch

Cut out hole

Detail connecting of Branch duct(Both aspects)

(77)3-1/32

(85)3-11/32

(298)11-3/411-1/16

(281)

(74)(80)(258)(241)2-29/323-5/3210-3/16

PLA-A36BA4PLA-A42BA4

PLA-A24BA4PLA-A30BA4

9-1/2

DCBA2

Refrigerant pipe···· 15.88Flared connection····5/8 inch

Refrigerant pipe···· 12.7Flared connection····1/2 inch

1

Refrigerant pipe···· 6.35Flared connection····1/4 inch

Refrigerant pipe···· 9.52Flared connection····3/8 inch

Models

PLA-A12BA4PLA-A18BA4

Min.19-11/16(500)

Grille

Ceiling

psuStlob noisne

egde rewol

Vane motor

Air intake grille

Air outlet hole

Air

outle

t hol

e

Auto vane(Air outlet)

Air

inta

ke h

ole

Air intake hole

GrilleCeiling

Keep 25/64(10) to 19/32(15)between unit ceiling and ceiling slab.

)(Connected the attachedflexible pipe or socket.

Drain pipeconnected to VP-25

Suspension bolt M10 or W3/8

Branch duct hole

Fresh air intake hole

Branch duct hole

Cei

ling

hole

Sus

pens

ion

bolt

pitc

h

Suspension bolt pitch

Ceiling hole

(5/1

6)(5

/16)

23-1

3/16

24-1

3/32

DEFROST/STAND BY lampReceiverOperation lamp

For wiring replacement kit terminal block

6-5/16

6-5/16

1

2

3-15

/16

5-1/

8

13-25/32

3-17/323-15/16 3-15/16

3-17/32

70� 6-

9/16

6-3/

32

5-29/32

6-7/8

19-11/16

19-1

1/16

23-1/2

M

M

M

M

3-17/641-27/64

37-3/8

3-17

/64

1-27

/64

37-3

/8

23-1

/2

1-15

/16~

2-3/

4

5-1/

2

6-11

/16

1-3/

8

11/1

6

4-1/

86-

9/64

7-15

/32 A B

6-5/

16

33-1

/16(

840)

5-29

/32

3-17

/32

C D

33-1/16

7-3/8

25/32 to 1-25/32(20~45)25/32 to 1-25/32(20~45) 33-27/32 to 35-13/16(860~910)31-7/8(810)

25/3

2 to

33-2

7/32

to 3

5-13

/16

25/3

2

15/1

66-

5/16

Indoor unit/Outdoor unit connecting terminal block

4-29/32( 125)

3-15/16( 100)

6-7/

32 120°

120°

Page 4: SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4-BS...SUBMITTAL DATA: PLA-A30BA4 & PUZ-HA30NHA4 ... GENERAL FEATURES ... Specifications are subject to change without notice.

1340 Satellite BoulevardSuwanee, GA 30024Toll Free: 800-433-4822www.mehvac.com

Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.

FORM# PLA-A30BA4 / PUZ-HA30NHA4 - 201409

DIMENSIONS: PUZ-HA30NHA4

Unit : mm<inch>

Min

. 100

0mm

<39-

3/8>

Min

. 150

mm

<5-2

9/32

>

Min

. 10m

m<3

/8>

Min

. 10m

m<3

/8>

FRE

E

<Fou

ndat

ion

bolt

heig

ht>

FOUN

DATI

ON

Ser

vice

spa

ce

Term

inal

Blo

ckLe

ft···P

ower

sup

ply

wirin

gRi

ght··

··Ind

oor/O

utdo

or w

iring

Ear

th te

rmin

al

Ser

vice

pan

el

Han

dle

1 2

23<29/32>

1076<42-3/8>

* 1 447<17-19/32>

* 1 443<17-7/16>

Han

dle

Fron

t pip

ing

cove

r

Rea

r pip

ing

cove

r

Air D

ischa

rge

Rear

Air

Inta

ke

Side

Air

Inta

ke

31<1-7/32>

145

<5-2

3/32>

145

<5-2

3/32>

220

<8-2

1/32>

30<1

-3/1

6>14

5<5

-23/3

2>

81<3-3/16>219<8-5/8>

71<2-13/16>

71<2

-13/

16>

Bot

tom

pip

ing

hole

(Kno

ckou

t)

Dra

in h

ole

5-33

<1-5

/16>

Han

dle

Sid

e A

ir In

take

Air

inta

ke

Rea

r Air

Inta

ke

Han

dle

Han

dle

40<1

-9/1

6>

74<2

-19/

32>

Whe

n in

stal

ling

the

cond

uit.

Set

the

atta

chm

ent t

o th

e in

ner s

ide

of e

ach

pane

l.

2-22

.2<7

/8>

1/2

Con

duit

atta

chm

ent

45<1

-25/3

2>40

<1-9

/16>

65<2

-9/1

6>92

<3-5

/8>

27<1-1/16>55<2-3/16>

23<29/32>73<2-7/8>63<2-1/2>

Rea

r pip

ing

hole

(Kno

ckou

t)

Rea

r tru

nkin

g ho

le(K

nock

out)

Cond

uit ho

le (2-

27<1

-1/16

>Kno

ckou

t)

92<3

-5/8

>

19<3

/4>55

<2-3

/16>

92<3

-5/8

>

75<2

-31/3

2>40

<1-9

/16>

73<2-7/8>63<2-1/2>

23<29/32>27<1-1/16>92<3-5/8>R

ight

pip

ing

hole

(Kno

ckou

t)R

ight

trun

king

hol

e(K

nock

out)

Con

duit

hole

(2

-27

<1-1

/16>

Kno

ckou

t)

92<3

-5/8

>

92<3

-5/8

>65

<2-9

/16>

45<1

-25/

32>

40<1

-9/1

6>

27<1-1/16>55<2-3/16>

23<29/32>73<2-7/8>

63<2-1/2>

Fron

t pip

ing

hole

(Kno

ckou

t)

Fron

t tru

nkin

g ho

le(K

nock

out)

Con

duit

hole

(2

-27

<1-1

/16>

Kno

ckou

t)

92

<3-5

/8>

371<14-19/32>

330<13> 30<1-3/16>

175<

6-7/

8>60

0<23

-5/8

>17

5<6-

7/8> 42

<1-2

1/32

>66

<2-5

/8>

950<

37-1

3/32

>

322<

12-1

1/16

>

1350<53-5/32>

635<25>

19<3/4>417<16-13/32>

370<14-9/16>

2-U

Sha

ped

notc

hed

hole

(Fou

ndat

ion

Bol

t M10

<W3/

8>)

56<2-7/32>

28<1-3/32>

53<2-3/32>

45<1-25/32>

2-12

36 O

val h

ole

(Fou

ndat

ion

Bol

t M10

<W3/

8>)

····R

efrig

eran

t GAS

pipe

conn

ction

(FLA

RE)

15.8

8<5/

8>···

·Ref

riger

ant L

IQUI

D pip

e co

nnec

tion

(FLA

RE)

9.5

2<3/

8>*1

····I

ndica

tion

of S

TOP

VALV

E co

nnec

tion

locat

ion.

Exam

ple

of N

otes

1 FRE

E SPA

CE (A

round

the u

nit)

2 SE

RVIC

E SP

ACE

3 FOU

NDAT

ION

BOLT

S4 P

IPING

-WIR

ING

DIRE

CTIO

NS

Pipi

ng K

nock

out H

ole

Deta

ils

The

diag

ram

bel

ow s

hows

aba

sic e

xam

ple.

Expl

antio

n of

par

ticul

ar d

etai

ls ar

egi

ven

in th

e in

stal

latio

n m

anua

ls et

c.

Dim

ensio

ns o

f spa

ce n

eede

dfo

r ser

vice

acce

ss a

resh

own

in th

e be

low

diag

ram

.

Plea

se s

ecur

e th

e un

it fir

mly

with

4 fo

unda

tion

(M10

<W3/

8>)

bolts

. (Bo

lts a

nd w

ashe

rs m

ust

be p

urch

ased

loca

lly.)

Pip

ing

and

wiri

ng c

onne

ctio

nsca

n be

mad

e fro

m 4

dire

ctio

ns:

front

, rig

ht, r

ear a

nd b

elow

.

Min

.10

mm

<3/8

>

Min.500mm<19-11/16>

Min.

500m

m<1

9-11/1

6>

Min.150mm<5-29/32>

Min.30mm<1-3/16>