Straight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) Primary 115VAC, 60 Hz., Secondary 115VAC Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length Perfect for circuit isolation or "Classic" bias power supply CSA certified (# LR3902) Remember - These units do NOT convert line frequency Transformer Schematic Blk Blk 0V Blu 110V Yel 115V Brn 120V Grn 130V Red 100V Blk/Red 90V Blk/Yel 115V Primary Secondary LINE ISOLATION - TAPPED TRANSFORMERS (115V to 90-130V) Primary 115VAC, 60 Hz. Secondary taps @ 90, 100, 110, 115, 120 & 130VAC Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length Perfect for critical line voltage needs (ex. Japanese 100V equipment). CSA certified (# LR3902) - except 169J Remember - These units do NOT convert line frequency Transformer Schematic Blk Blk Yel Yel Primary Secondary Part No. Capacity Dimensions (Inches) Wt. Lbs. VA Sec. Current ma A B C D E 169PS 15 130 1.88 2.07 2.50 1.50 1.19 1.3 169QS 40 260 2.19 2.50 2.63 1.75 1.44 2.5 169RS 60 435 2.50 2.75 3.06 2.00 1.69 3.3 169SS 90 650 2.50 3.25 3.06 2.00 2.19 4.5 169TS 135 870 3.13 3.50 3.81 2.50 2.19 6.5 169VS 175 1300 3.13 4.00 3.81 2.50 2.69 7 169WS 250 1700 3.75 4.00 4.56 3.00 2.81 12 Part No. Capacity VA Dimensions (Inches) Wt. Lbs. A B C D E 169C 100 2.50 3.50 3.06 2.00 2.44 4 169E 250 3.75 4.00 4.56 3.00 2.81 7 169G 500 6.75 5.50 4.56 3.00 4.31 15 169J 750 4.38 6.13 5.25 3.50 4.50 22 Line Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Transcript of Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169...

Page 1: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Straight Isolation - Hard Wired (169 Series)LINE ISOLATION TRANSFORMERS(115V to 115V)

Primary 115VAC, 60 Hz., Secondary 115VAC • Electrostatic shield between primary & secondary • Connection by flexible leads, 8" minimum length • Perfect for circuit isolation or "Classic" bias power •

supply CSA certified (# LR3902) • Remember• - These units do NOT convert line frequency

Transformer Schematic

Blk

Blk

0V Blu

110V Yel

115V Brn

120V Grn

130V Red

100V Blk/Red

90V Blk/Yel115V

Prim

ary

Sec

onda

ry

LINE ISOLATION - TAPPEDTRANSFORMERS

(115V to 90-130V)Primary 115VAC, 60 Hz. • Secondary taps @ 90, 100, 110, 115, 120 & 130VAC • Electrostatic shield between primary & secondary • Connection by flexible leads, 8" minimum length • Perfect for critical line voltage needs (ex. Japanese •

100V equipment). CSA certified (# LR3902) - except 169J • Remember• - These units do NOT convert line frequency

Transformer Schematic

Blk

Blk

Yel

YelPrim

ary

Sec

onda

ry

PartNo.

Capacity Dimensions (Inches)Wt. Lbs.VA Sec. Current

ma A B C D E

169PS 15 130 1.88 2.07 2.50 1.50 1.19 1.3169QS 40 260 2.19 2.50 2.63 1.75 1.44 2.5169RS 60 435 2.50 2.75 3.06 2.00 1.69 3.3169SS 90 650 2.50 3.25 3.06 2.00 2.19 4.5169TS 135 870 3.13 3.50 3.81 2.50 2.19 6.5169VS 175 1300 3.13 4.00 3.81 2.50 2.69 7169WS 250 1700 3.75 4.00 4.56 3.00 2.81 12

PartNo.

CapacityVA

Dimensions (Inches) Wt.Lbs.A B C D E

169C 100 2.50 3.50 3.06 2.00 2.44 4169E 250 3.75 4.00 4.56 3.00 2.81 7169G 500 6.75 5.50 4.56 3.00 4.31 15169J 750 4.38 6.13 5.25 3.50 4.50 22

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 2: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Primary 3-wire plug Secondary 3-wire receptacle

Straight Isolation - Plug In (171 Series)

LINE ISOLATION PLUG & RECEPTACLE

TRANSFORMERS(115V to 115V)

Primary 115VAC, 50/60 Hz., Secondary 115VAC • Provides circuit isolation. • Electrostatic shield between primary & secondary. • Hi-pot tested to 2 KV RMS. • Circuit breaker in primary. • Standard 3-wire, grounded plug & receptacle. • Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P). • Output (secondary) connected to 1 foot long 3-wire, standard North American grounded receptacle (NEMA 5-15R). • North American Mark of Safety - C UL & UL listed (File #E211544) • Remember• - These units do NOT convert line frequency

PartNo.

CapacityVA

Dimensions (Inches) Wt.Lbs.A B C D E

171A 100 3.80 5.06 4.68 3.00 3.38 6.5171B 200 3.80 5.56 4.68 3.00 3.88 8171C 300 3.80 6.06 4.68 3.00 4.38 11171E 500 3.80 7.06 4.68 3.00 5.38 14171F 750 4.40 8.70 5.39 3.50 6.78 30171G 1000 5.28 7.75 6.38 4.25 4.38 34.5

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 3: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Toroidal Straight Isolation - Plug In (178 & 240 Series)Toroidal Isolation

Plug In(120V to 120V)

Primary 120VAC, 50/60 Hz., Secondary 120VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light •

weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step •

down (120VAC to 120 VAC). Standard 3-wire, grounded plug (for use with adaptors •

for proper grounding). Input (primary) connected to a 5 foot long cord & •

standard North American plug (NEMA 5-15P). Output (secondary) connected to two standard 3 wire •

grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker •

lighted on-off switch & circuit breaker protected output.North American Mark of Safety - C UL & UL listed •

(File #E211544).Remember• - These units do NOT convert line

frequency.

Part No. CapacityVA # of Outlets Dimensions (Inches)

Length Width Height178CT 250 2 8.25 6.00 4.00178DT 500 2 9.00 6.00 4.00178ET 750 2 10.25 7.50 5.00178FT 1000 2 10.25 7.50 5.00178GT 1500 2 12.50 9.00 5.00

Toroidal IsolationPlug In

(240V to 240V)Primary 240VAC, 50/60 Hz., Secondary 240VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light •

weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step •

down (240VAC to 240VAC). Standard 3-wire, grounded plug (for use with adaptors •

for proper grounding). Input (primary) connected to a 5 foot long cord & •

standard North American plug (NEMA 6-15P). Output (secondary) connected to a standard 3 wire •

grounded duplex receptacle (NEMA 6-15R). Features include ventilated black steel case, rocker •

lighted on-off switch & circuit breaker protected output.North American Mark of Safety - C UL & UL listed •

(File #E211544).Remember• - These units do NOT convert line

frequency.

Part No. CapacityVA # of Outlets Dimensions (Inches)

Length Width Height240CT 250 2 8.25 6.00 4.00240DT 500 2 9.00 6.00 4.00240ET 750 2 10.25 7.50 5.00240FT 1000 2 10.25 7.50 5.00240GT 1500 2 12.50 9.00 5.00

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 4: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Straight Isolation - Constant Voltage - Plug In (CV Series)

Constant VoltageA.C. Regulator - Plug In

(120 V to 120V)AC regulating - protects against both brownouts & over voltage conditions. • Protects against any power problem other than a blackout. • Will operate through a 3 millisecond (minimum) blackout. • Long life - ferroresonant design - no moving parts. • Ferroresonant design also filters out surges, line harmonics, and RF noise. • Input 120VAC (+10 % to -25 %), 60 Hz • Output 120VAC (+/- 3 %). • Provides circuit isolation. • Noise Isolation (RF) of 120 db common mode, 60 db normal mode. • Spike attenuation: 250:1 minimum. • Sine wave output - total harmonic distortion (THD): 3 % • Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive. • Operating temperature range of -40 degrees C to +40 degrees C. • Standard 3-wire, grounded plug & receptacle. • Front panel lighted power switch. • Input (primary) connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges. • Integral molded, standard North American plug (NEMA 5-15P). • Output (secondary) connected to a rear mounted, standard North American, grounded receptacle (NEMA 5-15R) - •

quantity depends on power capacity of unit (see table below). Rugged two piece ventilated steel enclosure. • Finished in a grey/beige color, textured powder paint with rubber feet installed. • NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this •

through careful design, but these units are NOT usable in an office environment. NOTE 2: These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has •

no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers & line "polarity" testing devices will NOT function on the output as it is completely isolated.

North American Mark of Safety: C UL & UL listed (File #E211544).•

Part No.Capacity Number of

Rear Outlets

Dimensions (Inches) Wt.Lbs.VA Amps

(RMS) Height Width Depth

CV120300 300 2.5 2 7.00 7.13 12.30 25.3CV120600 600 5 4 9.00 10.13 19.50 48CV1201200 1200 10 4 9.00 10.13 19.50 74CV1201800 1800 15 6 12.00 12.13 20.50 95

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 5: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Toroidal Isolation - Step Up - Plug In (298 Series)

LINE ISOLATIONSTEP UP - PLUG IN(120V to 240V)

Primary 120VAC, 50/60 Hz., Secondary 240VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. • World wide applications, 50 or 60 Hz. operation, step UP (120VAC to 240 VAC). • Standard 3-wire, grounded plug (for use with adaptors for proper grounding). • Input (primary) connected to a 5 foot long cord & standard North American plug (NEMA 5-15P). • Output (secondary) connected to a standard N. American duplex - 3 wire grounded receptacles (NEMA 6-15R). • Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output.• North American Mark of Safety - C UL & UL listed (File #E211544).• Remember• - These units do NOT convert line frequency.

Part No.

Capacity VA

# of Outlets

Dimensions (Inches)Length Width Height

298CT 250 2 8.25 6.00 4.00298DT 500 2 9.00 6.00 4.00298ET 750 2 10.25 7.50 5.00298FT 1000 2 10.25 7.50 5.00298GT 1500 2 12.50 9.00 5.00

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 6: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Isolation - Step Down - Plug In (172 & 289 Series)LINE ISOLATION - STEP DOWN

PLUG-IN TRANSFORMERS(230V to 115V)

Primary 230VAC, 50/60 Hz. Secondary 115VAC • Circuit breaker in primary. • Provides circuit isolation & steps down primary voltage. • Hi-pot tested to 2 KV RMS. • Electrostatic shield between primary & secondary. • Input (primary) connected to a 5 foot long cord & •

North American 250V, 3-wire grounded plug (NEMA 6-15P).

Output (secondary) connected to a 1 foot long cord • & standard North American 125V, 3-wire grounded receptacle (NEMA 5-15R).

North American Mark of Safety - C UL & UL listed (File • #E211544).

Remember• - These units do NOT convert line frequency

PartNo.

CapacityVA

Dimensions (Inches) Wt.Lbs.A B C D E

172A 100 3.80 5.06 4.68 3.00 3.38 6.5172B 200 3.80 5.56 4.68 3.00 3.88 8.5172D 500 3.80 7.06 4.68 3.00 5.38 18.5172E 750 4.40 8.70 5.39 3.50 6.78 30.0172F 1000 5.28 7.75 6.38 4.25 4.38 34.5

LINE ISOLATION - TOROIDALSTEP DOWN - PLUG IN

(240V to 120V)Primary 240VAC, 50/60 Hz., Secondary 120VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light •

weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step •

down (240VAC to 120 VAC). Standard 3-wire, grounded plug (for use with adaptors •

for proper grounding). Input (primary) connected to a 5 foot long cord & •

standard 250V 2 pole, 3 wire - North American plug (NEMA 6-15P).

Output (secondary) connected to two standard 125V, • 3-wire grounded receptacles (NEMA 5-15R).

Features include ventilated black steel case, rocker • lighted on-off switch & circuit breaker protected output.

North American Mark of Safety - C UL & UL listed (File • #E211544)

Remember• - These units do NOT convert line frequency

Part No.

Capacity VA

# of Outlets

Dimensions (Inches)Length Width Height

289CT 250 2 8.25 6.00 4.00289DT 500 2 9.00 6.00 4.00289ET 750 2 10.25 7.50 5.00289FT 1000 2 10.25 7.50 5.00289GT 1500 2 12.50 9.00 5.00

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 7: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Isolation - Step Down - Plug In (179 Series)

LINE ISOLATIONSTEP DOWN - PLUG IN

(115V to 95V)Primary 115VAC, 50/60 Hz., Secondary 95VAC. • Provides circuit isolation. • Electrostatic shield between primary & secondary. • World wide applications, 50 or 60 Hz. operation, step down (115VAC to 95VAC). • Designed mainly for Japanese equipment operating in North America. • Perfect for operating "Classic" equipment that can not tolerate todays higher line voltages (ie..125VAC input will •

produce a stress free 105VAC output - at full load - PLUS - isolation and shielding). Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input (primary) connected to a 5 foot long cord and standard 3-wire, 125V North American plug (NEMA 5-15P).• Output (secondary) connected to two standard 3-wire, 125V grounded receptacles (NEMA 5-15R). • Features include ventilated black steel case, rocker lighted on-off switch & fuse protected output. • Remember• - These units do NOT convert line frequency

Input 3-wire plug

Output 3-wirereceptacle (2)

Part No.

Capacity VA

# of Outlets

Dimensions (Inches)Length Width Height

179C 250 2 6.00 6.75 4.75179D 500 2 6.00 8.25 4.75179E 750 2 7.00 8.25 5.38179F 1000 2 7.00 9.75 5.38179G 1500 2 8.50 9.00 6.75

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 8: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

230V Red

115V Blk

0V Yel

230V Red

115V Blk

0V Yel

"Auto" - Hard Wired (170 Series)HARD WIRED

LINE AUTOTRANSFORMERS

Single winding, does not provide isolation, for use where • equipment is already isolated and only voltage change is required.

Flexible world wide applications, 50 or 60 Hz. operation, • step down (230VAC to 115 VAC) or step up (115VAC to 230VAC).

Connection by flexible leads, 8" minimum length. • Models 170A, 170B, 170C & 170D are CSA certified •

(# LR 3902).Remember• - These units do NOT convert line

frequency.

HARD WIREDLINE AUTOTRANSFORMERS

Single winding, does not provide isolation, for use • where equipment is already isolated and only voltage change is required.

Flexible world wide applications, 50 or 60 Hz. • operation, step down (230VAC to 115 VAC) or step up (115VAC to 230VAC).

Totally enclosed rear case, includes handy internal • grounding bolt.

Extra vacuum varnish for use in high humidity. • Includes a rear mounted (but not wired), standard •

115VAC, 3-wire receptacle. Enclosed case with convenient knockouts and includes •

two cable clamps allowing for easy wire connections. Models 170SE, 170AE, 170BE, 170CE & 170DE are •

CSA certified (# LR3902) Connection by flexible leads, 8" minimum length • Remember• - These units do NOT convert line

frequency.

Part No.

Capacity VA

Dimensions (Inches) Wt.Lbs.A B C D E

170 50 2.19 2.63 2.63 1.75 1.56 2170A 100 2.50 3.00 3.06 2.00 1.94 3170B 200 3.13 3.50 3.81 2.50 2.19 4.5170C 300 3.13 4.00 3.81 2.50 2.69 6170D 500 3.75 4.50 4.56 3.00 3.31 10170E 750 3.75 5.50 4.56 3.00 4.31 14170F 1000 3.75 5.50 4.56 3.00 4.31 14.5170G 1500 4.38 6.63 5.30 3.50 5.10 22170J 2000 4.38 6.63 5.25 3.50 5.10 23

Part No.

Capacity VA

Dimensions (Inches) Wt.Lbs.A B C D E

170SE 50 3.13 4.00 4.13 2.25 3.13 3.5170AE 100 3.13 4.00 4.13 2.25 3.13 4170BE 200 3.13 4.25 4.13 2.25 3.38 5170CE 300 3.13 4.75 4.13 2.25 3.88 6.5170DE 500 3.75 5.00 4.88 2.75 4.13 10170EE 750 3.75 6.00 4.88 2.75 5.13 15170FE 1000 3.75 6.00 4.88 2.75 5.13 15.5170GE 1500 4.38 7.00 5.50 3.25 5.88 23.5170JE 2000 4.38 7.00 5.50 3.25 5.88 24.0

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 9: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

HARD WIREDLINE AUTOTRANSFORMERS

Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is • required.

Flexible world wide applications, 50 or 60 Hz. operation, 115VAC input. • Output taps @ 85, 95, 105, 110, 115 and 125VAC. • Ideal for manual line voltage adjustment for electronic equipment or small appliance operation. • Models 168B, 168C & 168D are CSA certified (# LR3902) • Connection by flexible leads, 8" minimum length. • Remember• - These units do NOT convert line frequency.

Part No.

Capacity VA

Dimensions (Inches) Wt.Lbs.A B C D E

168B 200 3.13 3.25 3.81 2.50 1.94 4.3168C 350 3.13 4.00 3.81 2.50 2.69 6.5168D 500 3.75 4.00 4.56 3.00 2.81 8168E 750 3.75 4.50 4.56 3.00 3.31 10168F 1000 3.75 5.50 4.56 3.00 4.31 14168H 1500 4.38 6.13 5.25 3.50 4.50 20168J 2000 4.38 6.63 5.25 3.50 5.10 23

"Auto" - Hard Wired (168 Series)

110V Red

125V Orn

0V Common Blk

95V Brn

115V Yel

105V Grn

85V Wht

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 10: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

"Auto" Step Down - Plug In (175 Series)

PLUG IN - STEP DOWNAUTOTRANSFORMERS

(230V to 115V)Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is •

required. World wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC). • Input is circuit breaker protected. • Hi-pot tested to 2 KV RMS. • Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input connected to a 5 foot cord & grounded North American 250V 3-wire plug (NEMA 6-15P).• Output connected to standard North American •

115V - 3 wire grounded receptacle (NEMA 5-15R). North American Mark of Safety - C UL & UL listed - File #E211544 • Remember• - These units do NOT convert line frequency.

Part No. Capacity VA

Dimensions (Inches) Wt.Lbs.A B C D E

175A-NA 100 3.16 4.25 3.81 2.50 2.94 3.5175B-NA 200 3.16 4.50 3.81 2.50 3.19 4.5175C-NA 300 3.16 5.00 3.81 2.50 3.69 6175D-NA 500 3.80 6.00 4.68 3.00 4.38 10175E-NA 750 3.80 7.06 4.68 3.00 5.38 14175F-NA 1000 3.80 7.06 4.68 3.00 5.38 14.5175G-NA 1500 4.40 6.63 5.39 3.50 6.09 22

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 11: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

"Auto" Step Up - Plug In (176 Series)

Autotransformer Step Up - Plug In(115V to 230V)

Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is • required.

World wide applications, 50 or 60 Hz. operation, step up (115VAC to 230VAC). • Input is circuit breaker protected.• Hi-pot tested to 2 KV RMS • Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input is connected to a 5 foot cord & standard grounded 125V North American plug (NEMA 5-15P) • Output is connected to a grounded North American 250V receptacle (NEMA 6-15R). • North American Mark of Safety - C UL & UL listed (File #E211544) • Remember• - These units do NOT convert line frequency.

Part No. Capacity VA

Dimensions (Inches) Wt. Lbs.A B C D E

176A 120 3.16 4.25 3.81 2.50 2.94 3.5176B 200 3.16 4.50 3.81 2.50 3.19 4.5176C 300 3.16 5.00 3.81 2.50 3.69 6176D 500 3.80 6.00 4.68 3.00 4.38 10176E 750 3.80 7.06 4.68 3.00 5.38 14176F 1000 3.80 7.06 4.68 3.00 5.38 14.5176G 1500 4.40 6.63 5.39 3.50 6.09 22

Line

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 12: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

©

www.hammondmfg.com

Line Transformers - AccessoriesINTERNATIONAL - GROUNDED

ADAPTOR PLUGS

For use with our 171, 172, 175, 176, 179, 289 & 298 transformers. • Heavy duty design with plastic shell & double wipe contacts. • Allows for ground connection between equipment and international power sources. • With a set of all 4 adaptors, they will accept equipment with plugs from virtually every •

country except South Africa! Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin- •

outs" of receptacles and/or plugs.

298G4 298G3 298G6 298G7

Rear View of all adaptors

Part No.

Grounded PlugType Used in the Countries of:

298G4 European Austria, Belgium, Finland, France, Germany, Middle East, Netherlands, Norway, Parts of Africa/Asia/South America/China/Tahiti & Caribbean, Sweden

298G3 British Hong Kong, Ireland, Malaysia, Parts of Africa, Caribbean, Singapore, U.K.298G6 Australian Australia, People’s Republic of China, S. Pacific Islands, New Zealand298G7 N. American Canada, Parts of the Caribbean/South America, Philippines, USALin

e

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 13: Straight Isolation - Hard Wired (169 Series) - · PDF fileStraight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) • Primary 115VAC, 60 Hz., Secondary

Line Transformer - Selection Guide

Steps To Proper Transformer Selection

What power is available (you need to know both voltage & frequency)? 1. Check the operating voltage of your equipment (is it single voltage or multiple?). 2. What line frequency will your equipment run on? Either 50, 60 or dual 50/60 Hz. (remember, a transformer can NOT 3. change line frequency). Use the chart below to determine your requirements:4.

1. Determine if your equipment is Electronic or Electrical: - Electronic = containing IC chips, transistors or a circuit such as a radio, shavers, electric toothbrush, computer printers, camcorder battery rechargers etc...(if in doubt, check with the manufacturer or refer to your manual). - Electrical = Simple heating device, such as irons, hair dryers, electric blankets, curling irons, etc... 2. Use the chart below to locate correct series & voltage conversion in the catalog series that follow:

IMPORTANT NOTESIsolation Transformers: Used for maximum safety, versatility (can be used on both electrical & electronic equipment) and isolation from the power source, used to step-up, step-down or for straight isolation. The disadvantage to using them is weight (about double the "Auto"), more expensive and larger size. This type of transformer is sometimes re-ferred to as "double-wound"

"Auto" Transformers: are non-isolating units and should be used where only a voltage change is required. The ad-vantages to using them are light weight (generally half that of an isolation unit), less expensive and smaller size. The disadvantage is no isolation from the power source. This type of transformer is sometimes referred to as a "converter".

Adaptors: We strongly recommend that 3-prong "grounded" plugs be used with all of our products. They should be used only with our "grounded" adaptors. Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.

Power Available Your Equipment Transformer Type Required(You may also need plug adaptors)Voltage Frequency Voltage Frequency

115 60 100 50/60 Step Down115 50 115 50 None Required - or - Straight Isolation115 50 115 60 Will Not Work115 50 115/230 50/60 None Required - or - Straight Isolation115 60 115 60 None Required - or - Straight Isolation115 60 230 50 Will Not Work115 60 230 60 Step Up115 60 115/230 50/60 None Required - or - Straight Isolation230 50 115 50 Step Down230 50 115 60 Will Not Work230 50 115/230 50/60 None Required - or - Straight Isolation230 60 115 60 Step Down230 60 230 50 Will Not Work230 60 230 60 None Required - or - Straight Isolation230 60 115/230 50/60 None Required - or - Straight Isolation

Transformer Type(determined from

chart above)

Your Equipment Type

Electronic ElectricalStep Up Use Isolation (series 298) Could use “Auto” (series 170 or 170E)

Step Down Use Isolation (series 172, 179 or 289) Could use “Auto” (series 175)Straight Isolation Use Isolation (series 169 or 171) -