Reproduction 1. Asexual Reproduction 2. Sexual Reproduction.
STEP Control Panel · THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF...
Transcript of STEP Control Panel · THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF...
-
64
6
4
48.5
15.456.0
Clean out port
STEP Control PanelBlower Housing
Vent
75.0 81.0
Notes:The cleanout port at the front of •the tank will not be interfered with.The outlet tee will be removed to •allow the FAST® treatment system outlet to be installed properly.See Waite Tank drawing "1000 •Gallon Mid-Seam Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon •requirements.The volume of the septic and •dosing tank will be as required in OAR 340-071.All connections into and out of •pumping system shall be sealed and water tight.The pumping system must be •properly vented.All electrical connections shall •meet local codes.Reference "Short-FAST-Module-•Procedure" and MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.5 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET1 OF 1
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Dosing SepticINI-01-Q
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
0 0
BIO·MICROBICS
rtroxApproved
-
64
4
48.50
15.4
6.0
Clean out port
STEP Control PanelBlower Housing
Vent Discharge Pipe
Float Assembly
Effluent Pump
Notes:The cleanout port at the front of the tank will not be interfered with.•The outlet tee will be removed to allow the FAST® treatment system outlet to be •installed properly.See Waite Tank drawing "1000 Gallon Mid-Seam Septic Tank" for detailed tank •dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be as required in OAR 340-071.•All connections into and out of pumping system shall be sealed and water tight.•The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and MicroFAST drawings for additional •information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.5 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET2 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Post Pump TankINI-01-Q
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
rtroxApproved
-
18
36 40
71.75
High Level Alarm
Control Panel
Sealed Conduit box
24" PVC Riser
Pump On or
On/ OFF
lifting cable
Fiberglass sealed bottom
Check Valve
Pump Offor
Redundant Off
PVC pipe from MicroFASTTreatment System
24" Gasketed Fiberglass Lid
Discharge Pipe
Level Control Assembly
Effluent, Sewage Pump
Concrete anti-floatation base (See installation notes.)
NOTES:Installation
The Basin is composed of a plastic pipe with a fiberglass bottom and •gasketed fiberglass lid. An optional anti-flotation ring may be provided to prevent the basin from floating.A 3" to 4" thick concrete base is required for anchoring purposes in •areas where floatation of the vault is possible.All connections into and out of pumping system shall be sealed and •water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•
Electrical Content level control and pump power cords to junction box as shown.•Make certain all compression fittings are tight.•Install control panel.•Run wires to control panel through conduit and connect cords coming •into the connection box. Mark or trace each incoming wire so that it can be connected to the proper cord.
Starting SystemOpen Ball Valve•Run water into basin until the "On" level control starts the pump. Allow •pump to operate until sump level drops, deactivating "Off level control, stopping pump.
OperationsDraw down on this Pump vault is 1.96 gallons per inch. 18" operational •zone between float 18" float and 36" float creates a pump volume of 35.25 gallons per dose.Foats can be moved for various desired dose volumes and pumps. •
Notes:The cleanout port at the front of the tank will not be •interfered with.The outlet tee will be removed to allow the FAST® •treatment system outlet to be installed properly.See Waite Tank drawing "1000 Gallon Mid-Seam •Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be as •required in OAR 340-071.All connections into and out of pumping system •shall be sealed and water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and •MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.5 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET3 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Distribution VaultINI-01-I
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
l
BIO·MICROBICS
rtroxApproved
-
75.0 81.0
64
4
56.0 15.5
48.5
6.25
Clean out port
STEP Control PanelBlower Housing
Vent
Notes:The cleanout port at the front of •the tank will not be interfered with.The outlet tee will be removed to •allow the FAST® treatment system outlet to be installed properly.See Waite Tank drawing "1000 •Gallon Mid-Seam Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon •requirements.The volume of the septic and •dosing tank will be as required in OAR 340-071.All connections into and out of •pumping system shall be sealed and water tight.The pumping system must be •properly vented.All electrical connections shall •meet local codes.Reference "Short-FAST-Module-•Procedure" and MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.75 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET1 OF 1
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Dosing SepticINI-01-Q
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
t o BIO·MICROBICS
rtroxApproved
-
64
4
48.5
15.5
6.25
Clean out port
STEP Control PanelBlower HousingDischarge Pipe
Float Assembly
Effluent Pump
Vent
Notes:The cleanout port at the front of the tank will not be interfered with.•The outlet tee will be removed to allow the FAST® treatment system outlet to be •installed properly.See Waite Tank drawing "1000 Gallon Mid-Seam Septic Tank" for detailed tank •dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be as required in OAR 340-071.•All connections into and out of pumping system shall be sealed and water tight.•The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and MicroFAST drawings for additional •information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.75 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET2 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Post Pump TankINI-01-Q
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
rtroxApproved
-
18
36 40
71.75High Level Alarm
Discharge Pipe
Control Panel
Sealed Conduit box 24" PVC Riser
24" Gasketed Fiberglass Lid
Pump On or
On/ OFF
lifting cable
Fiberglass sealed bottom
Check Valve
Pump Offor
Redundant Off
PVC pipe from MicroFASTTreatment System
Level Control Assembly
Effluent, Sewage Pump
Concrete anti-floatation base (See installation notes.)
NOTES:Installation
The Basin is composed of a plastic pipe with a fiberglass bottom and •gasketed fiberglass lid. An optional anti-flotation ring may be provided to prevent the basin from floating.A 3" to 4" thick concrete base is required for anchoring purposes in •areas where floatation of the vault is possible.All connections into and out of pumping system shall be sealed and •water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•
Electrical Content level control and pump power cords to junction box as shown.•Make certain all compression fittings are tight.•Install control panel.•Run wires to control panel through conduit and connect cords coming •into the connection box. Mark or trace each incoming wire so that it can be connected to the proper cord.
Starting SystemOpen Ball Valve•Run water into basin until the "On" level control starts the pump. Allow •pump to operate until sump level drops, deactivating "Off level control, stopping pump.
OperationsDraw down on this Pump vault is 1.96 gallons per inch. 18" operational •zone between float 18" float and 36" float creates a pump volume of 35.25 gallons per dose.Foats can be moved for various desired dose volumes and pumps. •
Notes:The cleanout port at the front of the tank will not •be interfered with.The outlet tee will be removed to allow the FAST® •treatment system outlet to be installed properly.See Waite Tank drawing "1000 Gallon Mid-Seam •Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be •as required in OAR 340-071.All connections into and out of pumping system •shall be sealed and water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and •MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.75 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET3 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Distribution VaultINI-01-I
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
BIO·MICROBICS
rtroxApproved
-
75.0 81.00
64
4
56
48.5
6.0
16.9
Clean out port
STEP Control PanelBlower Housing
Vent
Notes:The cleanout port at the front of the •tank will not be interfered with.The outlet tee will be removed to allow •the FAST® treatment system outlet to be installed properly.See Waite Tank drawing "1000 Gallon •Mid-Seam Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon •requirements.The volume of the septic and dosing •tank will be as required in OAR 340-071.All connections into and out of •pumping system shall be sealed and water tight.The pumping system must be properly •vented.All electrical connections shall meet •local codes.Reference "Short-FAST-Module-•Procedure" and MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.90 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET1 OF 1
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Dosing SepticINI-01-Q
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
0 0
BIO·MICROBICS
rtroxApproved
-
64
4
48.5
16.9
6.0
Clean out port
STEP Control PanelBlower Housing
VentDischarge Pipe
Float Assembly
Effluent Pump
Notes:The cleanout port at the front of the tank will not be interfered with.•The outlet tee will be removed to allow the FAST® treatment system outlet to be •installed properly.See Waite Tank drawing "1000 Gallon Mid-Seam Septic Tank" for detailed tank •dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be as required in OAR 340-071.•All connections into and out of pumping system shall be sealed and water tight.•The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and MicroFAST drawings for additional •information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.90 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET2 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Post Pump TankINI-01-Q
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
rtroxApproved
-
18
36 40
71.75High Level Alarm
Discharge Pipe
Control Panel
Sealed Conduit box
24" PVC Riser
Pump On or
On/ OFF
lifting cable24" Gasketed Fiberglass Lid
Fiberglass sealed bottom
Check Valve
Pump Offor
Redundant Off
PVC pipe from MicroFASTTreatment System
Level Control Assembly
Effluent, Sewage Pump
Concrete anti-floatation base (See installation notes.)
NOTES:
The Basin is composed of a plastic pipe with a fiberglass bottom and •gasketed fiberglass lid. An optional anti-flotation ring may be provided to prevent the basin from floating.A 3" to 4" thick concrete base is required for anchoring purposes in •areas where floatation of the vault is possible.All connections into and out of pumping system shall be sealed and •
The pumping system must be properly vented.•All electrical connections shall meet local codes.•
Content level control and pump power cords to junction box as shown.•Make certain all compression fittings are tight.•Install control panel.•Run wires to control panel through conduit and connect cords coming •into the connection box. Mark or trace each incoming wire so that it can be connected to the proper cord.
Starting SystemOpen Ball Valve•Run water into basin until the "On" level control starts the pump. Allow •pump to operate until sump level drops, deactivating "Off level control, stopping pump.
Draw down on this Pump vault is 1.96 gallons per inch. 18" operational •zone between float 18" float and 36" float creates a pump volume of 35.25 gallons per dose.Foats can be moved for various desired dose volumes and pumps. •
Notes:The cleanout port at the front of the tank will not be •interfered with.The outlet tee will be removed to allow the FAST® •treatment system outlet to be installed properly.See Waite Tank drawing "1000 Gallon Mid-Seam •Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be as •required in OAR 340-071.All connections into and out of pumping system shall •be sealed and water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and •MicroFAST drawings for additional information.
WEIGHT
UNLESS NOTED
ARE IN INCHES [CENTIMETERS]
± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Mid-Seam Waite 0.90 MCF
REVISED 2/9/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET3 OF 3
lbWEIGHT
UNLESS NOTED
ARE IN INCHES [CENTIMETERS]
± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Distribution VaultINI-01-I
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/9/2010 REV.
lb
BIO-MICROBICS © 2010
1
BIO·MICROBICS
rtroxApproved
-
88
6.0
9.25
4.50
36.4
67.75
Pump Control PanelBlower Housing
Vent
86.00
100.50
Notes:The inlet will not be interfered with.•The outlet tee will be removed to •allow the FAST® treatment system outlet to be installed properly.See Waite Tank drawing "2000 •Gallon Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon •requirements.The volume of the septic and •dosing tank will be as required in OAR 340-071.All connections into and out of •pumping system shall be sealed and water tight.The pumping system must be •properly vented.All electrical connections shall •meet local codes.Reference "Short-FAST-Module-•Procedure" and MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Waite 1.5 MCF
REVISED 2/25/2010
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET1 OF 1
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED AB
Dosing SepticINI-01-T
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/25/2010 REV.
lb
BIO-MICROBICS © 2010
I-
0
rtroxApproved
-
77.50
4.50
88
6.0
67.75
9.25
36.4
Pump Control Panel
Blower HousingVent
Discharge Pipe
Pump
Notes:The inlet will not be interfered with.•The outlet tee will be removed to allow the FAST® treatment system •outlet to be installed properly.See Waite Tank drawing "2000 Gallon Septic Tank" for detailed tank •dimensions.All exterior pipe size as per Oregon requirements.•The volume of the septic and dosing tank will be as required in OAR •340-071.All connections into and out of pumping system shall be sealed and •water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•Reference "Short-FAST-Module-Procedure" and MicroFAST drawings for •additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
Waite 1.5 MCF
REVISED 2/25/2010
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET2 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
AB
Distribution TankINI-01-U
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/25/2010 REV.
lb
BIO-MICROBICS © 2010
rtroxApproved
-
20
36 41
71.75High Level Alarm
Discharge Pipe
Control Panel
Sealed Conduit box
24" PVC Riser
24" Gasketed Fiberglass Lid
Pump On or
On/ OFF
lifting cable
Fiberglass sealed bottom
Check Valve
Pump Offor
Redundant Off
PVC pipe from MicroFASTTreatment System
Level Control Assembly
Effluent, Sewage Pump
Concrete anti-floatation base (See installation notes.)
NOTES:The inlet will not be interfered with.•The outlet tee will be removed to allow •the FAST® treatment system outlet to be installed properly.See Waite Tank drawing "2000 Gallon •Septic Tank" for detailed tank dimensions.All exterior pipe size as per Oregon •requirements.The volume of the septic and dosing tank •will be as required in OAR 340-071.All connections into and out of pumping •system shall be sealed and water tight.The pumping system must be properly •vented.All electrical connections shall meet local •codes.Reference "Short-FAST-Module-•Procedure" and MicroFAST drawings for additional information.
8/11/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
Waite 1.5 MCF
REVISED 2/25/2010
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET3 OF 3
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
Distribution VaultINI-01-J
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
2/25/2010 REV.
lb
BIO-MICROBICS © 2010 CTCAB
rtroxApproved
-
18
36 40
71.75
High Level Alarm
Discharge Pipe
Control Panel
Sealed Conduit box
Concrete anti-floatation base (See installation notes.)
24" PVC Riser
24" Gasketed Fiberglass Lid
Pump On or
On/ OFF
lifting cable
Fiberglass sealed bottom
Check Valve
Pump Offor
Redundant Off
PVC pipe from MicroFASTTreatment System
Level Control Assembly
Effluent, Sewage Pump
NOTES:Installation
The Basin is composed of a plastic pipe with a fiberglass bottom and •gasketed fiberglass lid. An optional anti-flotation ring may be provided to prevent the basin from floating.A 3" to 4" thick concrete base is required for anchoring purposes in areas •where floatation of the vault is possible.All connections into and out of pumping system shall be sealed and •water tight.The pumping system must be properly vented.•All electrical connections shall meet local codes.•
Electrical Content level control and pump power cords to junction box as shown.•Make certain all compression fittings are tight.•Install control panel.•Run wires to control panel through conduit and connect cords coming •into the connection box. Mark or trace each incoming wire so that it can be connected to the proper cord.
Starting SystemOpen Ball Valve•Run water into basin until the "On" level control starts the pump. Allow •pump to operate until sump level drops, deactivating "Off level control, stopping pump.
OperationsDraw down on this Pump vault is 1.96 gallons per inch. 18" operational •zone between float 18" float and 36" float creates a pump volume of 35.25 gallons per dose.Foats can be moved for various desired dose volumes and pumps. •
8/17/2009
WEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
Pump Vault
REVISED 1/22/2010PF
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
SIZE DRAWING NUMBER
ANAME DATE SHEET1 OF 1
lbWEIGHT
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS]TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
DRAWNCHECKED
CTC
PF
Pump Vault ProfileINI-01-G
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.
NAME DATE
1/22/2010 REV.
lb
BIO-MICROBICS © 2010
rtroxApproved
BioMicrobics_Waite_TS1_Web.pdfMid-Seam Waite 0 5 MCF (3).pdfDosing SepticDrawing View21Drawing View22
Post Pump TankDrawing View26
Distribution VaultDrawing View24Drawing View25
Waite1.5.pdfFASTApprovedDrawingWaite 2000 g with 1.5 March.pdfDosing SepticDrawing View21Drawing View22
Distribution TankDrawing View23
Distribution VaultDrawing View24Drawing View25
Pump Vault MArch 2010.pdfPump Vault ProfileDrawing View1Drawing View2
Mid-Seam Waite 0.75_March 2010.pdfFASTApprovedDrawingMid-Seam Waite 0.75 MCFMarch 2010.pdfDosing SepticDrawing View22Drawing View28
Post Pump TankDrawing View27
Distribution VaultDrawing View24Drawing View30
Mid-SeamWaite1.5March2010.PDFFASTApprovedDrawingMid-Seam Waite 0.9 March2010.PDFDosing SepticDrawing View22Drawing View29
Post Pump TankDrawing View23
Distribution VaultDrawing View24Drawing View31