Step by step installation guide -32/40/50mm Push-Fit Waste

1
Step by step installation guide -32/40/50mm Push-Fit Waste For more information visit www.floplast.co.uk Roofline, Window and Cladding Systems Rainwater Systems Soil & Waste Systems Underground Drainage Systems MDPE Systems Hot & Cold Plumbing Systems Measure and cut the pipe to size. 1 Lubricate the ring seal in the socket. 2 Push the pipe into the socket. 3 All pipes must be supported both vertically and horizontally. 4 Pipework support (BS EN 12056:2000) Maximum distances for support Pipe Size Vertical Horizontal 32mm 1.2m 0.5m 40mm 1.2m 0.5m 50mm 1.2m 0.6m WARNING Ensure you purchase the correct pipe for your chosen system.

Transcript of Step by step installation guide -32/40/50mm Push-Fit Waste

Page 1: Step by step installation guide -32/40/50mm Push-Fit Waste

Step by step installation guide -32/40/50mm Push-Fit Waste

For more information visit www.floplast.co.uk

Roofline, Window and Cladding Systems

Rainwater Systems

Soil & Waste Systems

Underground Drainage Systems

MDPE Systems

Hot & Cold Plumbing Systems

Measure and cut the pipe to size.

1

Lubricate the ring seal in the socket.

2

Push the pipe into the socket.

3

All pipes must be supported both vertically and horizontally.

4 Pipework support (BS EN 12056:2000)Maximum distances for support

Pipe Size Vertical Horizontal32mm 1.2m 0.5m

40mm 1.2m 0.5m

50mm 1.2m 0.6m

WARNINGEnsure you purchase the correct pipe

for your chosen system.