STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of...

15
STANDARD ELECTRODE POTENTIALS

Transcript of STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of...

Page 1: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

STANDARD ELECTRODE POTENTIALS

Page 2: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

THE STANDARD HYDROGEN ELECTRODE

In order to measure the potential of an electrode, it is compared to a reference electrode – the standard hydrogen electrode.

The standard half reaction is the reduction of hydrogen:

2H+ + 2e- → H2

The electrode potential of this half cell = 0,00V

Page 3: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Operating conditions:

STP

Temperature = 298K

Pressure = 1 atm

or 101,3 2kPa

[H+] = 1 mol.dm-3

Page 4: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Measuring the standard electrode potential of zinc by connecting a zinc electrode to the hydrogen electrode.

Page 5: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

The hydrogen electrode is the cathode.

2H+(aq) + 2e- → H2(g)

The zinc electrode is the anode.

Zn(s) → Zn2+(aq) + 2e-

The reading on the voltmeter is 0,76V and because electrons flow from the zinc to the hydrogen electrode

Eo for the zinc half cell = - 0,76V

Page 6: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Abbreviated redox table

Page 7: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Full Redox potential table

Any substance on the right will spontaneously react with something above it on the right of the table – and vice versa.

Page 8: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

When using the table:

• strong reducing agents are at the top of the table.

• when combining half reactions, the one higher up the table will be the reducing agent.

• when combining half reactions, the half reaction located higher up the table is written in reverse (from left to right) and the one lower down from right to left.

Page 9: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Using the table of standard electrode potentials:

• determine the emf of a cell.

• predicting whether a redox reaction will occur spontaneously;

• balancing redox reactions.

Page 10: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Determining the emf of a cell:

Eo cell = Eo reduction – Eo

oxidation

= Eo oxidising agent – Eo

reducing agent

= Eo cathode – Eo

anode

Page 11: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

For the cell:

Zn / Zn2+ // Cu2+ / Cu

The zinc electrode is the reducing agent and the anode as oxidation occurs at that electrode.

Eo cell = Eo Cu – Eo

Zn

= 0,34 – (-0,76)

= +1,10V

Page 12: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Predicting whether a redox reaction will occur spontaneously.

• Write down the equation as you expect it to occur.

• from the equation decide which half cell is the reducing/oxidising agent.

• Determine Eocell based on this information.

• If Eocell is a positive number, the reaction, as

written, is non-spontaneous.

Page 13: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Will the following reaction occur spontaneousky:

Pb2+(aq) + 2Br-

(aq) → Br2(l) + Pb(s)

Pb2+ + 2e- → Pb Eo = - 0.13V reduction

2Br- → Br2 + 2e- Eo = + 1,06V oxidation

Eocell = Eo

Pb – EoBr = (- 0,13) – (+ 1,06)

= - 1,19V

Eo is negative and so the reaction is non-spontaneous

Page 14: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

Balancing redox equations.

Hydrogen sulphide reduces potassium dichromate. Write a balanced equation for this reaction.

H2S → 2H+ + S + 2e-

Cr2O72- + 14H+ + 6e- → Cr3+ + 7H2O

Multiply the first equation by 3 to balance the electrons, cancel out any ions/molecules that occur on opposite sides of the equation and add up the remaining ions/molecules to give the balanced ionic equation.

Page 15: STANDARD ELECTRODE POTENTIALS. THE STANDARD HYDROGEN ELECTRODE In order to measure the potential of an electrode, it is compared to a reference electrode.

3H2S → 6H+ + 3S + 6e-

Cr2O72- + 14H+ + 6e- → Cr3+ + 7H2O

3H2S + Cr2O72- + 8H+ → Cr3+ + 7H2O + 3S