SR-M - di-soric.com di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 /...

2
209200 © di-soric | Subject to modifications | 04/01/20 | Page 1 (2) SR-M Safety relay di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com TECHNICAL INFORMATION (typ.) +20°C, 24 V DC Characteristic parameters Type 4 (IEC/TS 61496-2), SILCL 3 (IEC 62061) PL e - Cat. 4 (EN ISO 13849-1) Mounting rail fastening according to EN 50022-35 standard Operating principle Safety relay with muting function Size 99 x 35 x 114.5 mm (Dimensions) Service voltage 19,2 ... 28,8 V DC Inverse polarity protection Yes Display LED for input / output status, muting sensor inputs and failure diagnosis Start / restart automatic / manual (selectable on terminal block), interlock External Device Monitoring - EDM Feedback input, enabling selectable Reaction time < 20 ms Ambient temperature, operation 0 … +55 °C Protection class IP 20, (housing), IP 2X, (terminal blocks) Suitable for all safety light curtains /-grids Connection on terminal blocks Scope of delivery Multi-language instruction manual Two-channel inputs for safety light curtains / -grids 1 Status output PNP (1x), 100 mA, 24 V DC Inputs for muting sensors 2x, 24 V DC, PNP, dark-on Muting enable input 24 V DC, PNP or relay (highly active) Muting lamp output 24 V DC, 0,5 ... 5 W Muting time-out 30 sec. or infinite, selectable 99 35 114.5 Safety instructions All the installation, connection and safety regulations, as per our technical information, have to be strictly adhered to. The set-up of the products have to be made by skilled staff, only. Repair exclusively made by di-soric. E S P E Usable for safety light curtains / -grids with safety level type 2 and type 4 Integrated muting function Additional security functions Start / Restart Interlock EDM Feedback input for extra external contractors monitoring LED indicators for status, muting and diagnosis Inverse polarity protection

Transcript of SR-M - di-soric.com di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 /...

Page 1: SR-M - di-soric.com di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 info@di-soric.com

209200

© di-soric | Subject to modifications | 04/01/20 | Page 1 (2)

SR-M

Safety relay

di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach

Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com

TECHNICAL INFORMATION (typ.) +20°C, 24 V DC

Characteristic parameters   Type 4 (IEC/TS 61496-2), SILCL 3 (IEC 62061) PL e - Cat. 4 (ENISO 13849-1)

Mounting   rail fastening according to EN 50022-35 standard

Operating principle   Safety relay with muting function

Size   99 x 35 x 114.5 mm (Dimensions)

Service voltage   19,2 ... 28,8 V DC

Inverse polarity protection   Yes

Display   LED for input / output status, muting sensor inputs and failurediagnosis

Start / restart   automatic / manual (selectable on terminal block), interlock

External Device Monitoring - EDM   Feedback input, enabling selectable

Reaction time   < 20 ms

Ambient temperature, operation   0 … +55 °C

Protection class   IP 20, (housing), IP 2X, (terminal blocks)

Suitable for   all safety light curtains /-grids

Connection   on terminal blocks

Scope of delivery   Multi-language instruction manual

Two-channel inputs for safety light curtains / -grids   1

Status output   PNP (1x), 100 mA, 24 V DC

Inputs for muting sensors   2x, 24 V DC, PNP, dark-on

Muting enable input   24 V DC, PNP or relay (highly active)

Muting lamp output   24 V DC, 0,5 ... 5 W

Muting time-out   30 sec. or infinite, selectable

99

35

114.5

Safety instructionsAll the installation, connection and safety regulations, as per our technicalinformation, have to be strictly adhered to.The set-up of the products have to be made by skilled staff, only.Repair exclusively made by di-soric.

E S P E

Usable for safety light curtains / -grids with safety level type 2

and type 4

Integrated muting function

Additional security functions

Start / Restart Interlock

EDM Feedback input for extra external contractors monitoring

LED indicators for status, muting and diagnosis

Inverse polarity protection

Page 2: SR-M - di-soric.com di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 info@di-soric.com

di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach

Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com

SR-M

Safety relay

209200

© di-soric | Subject to modifications | 04/01/20 | Page 2 (2)

TECHNICAL INFORMATION (typ.) +20°C, 24 V DC

Override time-out   15 min.

Override   2 operating modes selectable: manual action with hold to run orautomatic with pulse command

Safety relay outputs   NO (2x), 2 A / 250 V AC