Revised in Feb. 2017 1/61 Spec. No.EN382EzCTS-J EzCTS Specifications Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 1.EzCTS(Ez Communication Tool Software) -. General This software is the software which unifies the following software. control communication tool software for CSD-912 (hereinafter abbreviated as CSD-912D-01) control communication tool software for CSD-903 (hereinafter abbreviated as CSD-903D-01) control communication tool software for CSD-892-73 (hereinafter abbreviated as CSD-892-73D-01) control communication tool software for CSD-892-74(hereinafter abbreviated as CSD-892-74D-01) control communication tool software for CSD-892-76(hereinafter abbreviated as CSD-892-76D-01) control communication tool software for CSD-893-76(hereinafter abbreviated as CSD-893-76D-01) control communication tool software for CSD-892-07-25(hereinafter abbreviated as CSD-892-07-25D-01) control communication tool software for CSD-918(hereinafter abbreviated as CSD-918D-02) control communication tool software for CSD-709(hereinafter abbreviated as CSD-709D-02) As for the details for each software, we describe in the Chapter 2. CSD-912D-01 Communication tool software for CSD-912 and in the Chapter 3. CSD-903D-01 Communication tool software for CSD-903 . CSD-892-73D-01, CSD-892-74D-01, CSD-892-76D-01, and CSD-892-07-25D-01 we describe in the clause of 4.CSD-892-xxD-01 Communication tool software for CSD-892-xx . and in the Chapter 5. CSD-893-76D-01 Communication tool software for CSD-893-76 . CSD-918 we describe in the clause of 6.CSD-918D-02 Communication tool software for CSD-918 . CSD-709 we describe in the clause of 7.CSD-709D-02 Communication tool software for CSD-709 . -. Functions of software The functions that the software possesses are as follows: Activation of CSD-912D-01. Activation of CSD-918D-02. Activation of CSD-903D-01. Activation of CSD-892-73D-01. Activation of CSD-892-74D-01. Activation of CSD-892-76D-01. Activation of CSD-892-07-25D-01. Activation of CSD-893-76D-01. Activation of CSD-709D-02. Setting of the system.

Transcript of Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software...

Page 1: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

1/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

1.EzCTS(Ez Communication Tool Software)

1-1. General This software is the software which unifies the following software. ・control communication tool software for CSD-912 (hereinafter abbreviated as CSD-912D-01) ・control communication tool software for CSD-903 (hereinafter abbreviated as CSD-903D-01) ・control communication tool software for CSD-892-73 (hereinafter abbreviated as CSD-892-73D-01) ・control communication tool software for CSD-892-74(hereinafter abbreviated as CSD-892-74D-01) ・control communication tool software for CSD-892-76(hereinafter abbreviated as CSD-892-76D-01) ・control communication tool software for CSD-893-76(hereinafter abbreviated as CSD-893-76D-01) ・control communication tool software for CSD-892-07-25(hereinafter abbreviated as CSD-892-07-25D-01) ・control communication tool software for CSD-918(hereinafter abbreviated as CSD-918D-02) ・control communication tool software for CSD-709(hereinafter abbreviated as CSD-709D-02) As for the details for each software, we describe in the Chapter 2. CSD-912D-01【Communication tool software for CSD-912】and in the Chapter 3. CSD-903D-01【Communication tool software for CSD-903】. CSD-892-73D-01, CSD-892-74D-01, CSD-892-76D-01, and CSD-892-07-25D-01 we describe in the clause of 4.CSD-892-xxD-01 【Communication tool software for CSD-892-xx】. and in the Chapter 5. CSD-893-76D-01【Communication tool software for CSD-893-76】. CSD-918 we describe in the clause of 6.CSD-918D-02 【Communication tool software for CSD-918】. CSD-709 we describe in the clause of 7.CSD-709D-02 【Communication tool software for CSD-709】.

1-2. Functions of software The functions that the software possesses are as follows: Activation of CSD-912D-01. Activation of CSD-918D-02. Activation of CSD-903D-01. Activation of CSD-892-73D-01. Activation of CSD-892-74D-01. Activation of CSD-892-76D-01. Activation of CSD-892-07-25D-01. Activation of CSD-893-76D-01. Activation of CSD-709D-02. Setting of the system.

Page 2: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

2/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

1-3. Specifications for functions 1-3-1. Operating windows

(1) Main Menu

CSD-912(F1) Activation of CSD-912D-01. CSD-903(F2) Activation of CSD-903D-01. CSD-892-73(F3) Activation of CSD-892-73D-01. CSD-892-74(F4) Activation of CSD-892-74D-01. CSD-892-76(F5) Activation of CSD-892-76D-01. CSD-893-76(F6) Activation of CSD-893-76D-01. CSD-892-07-25(F7) Activation of CSD-892-07-25D-01. CSD-918(F8) Activation of CSD-918D-02. CSD-709(F9) Activation of CSD-709D-02.

Page 3: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

3/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Version information window It’s version information shows.

(3) System setting window

Set the localization.

Page 4: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

4/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

2.CSD-912D-01【Communication tool software for CSD-912】

2-1. General By sending/receiving the commands between the Graphic Digital Indicator CSD-912 and your Personal computer, you can read-in the setting parameter/trend graphic data of CSD-912 and also write the optional parameter to CSD-912 through the software. Moreover, setting parameter that has read-in and the trend graphic data can be output to the file.

2-2. Software functions The functions in this software are as follows: Reading/Writing the setting parameter (All the items lump together)

*The parameters read-in are shown on the reading column of list. *Writing parameter is set on the writing column of list. *A parameter different form then compare value displays the set value in red. (Read and Write fields common.) * The Compare value is set from the file of the default value or the configuration parameter. *The item of targeted lock of calibration is prohibited from writing. Reading file of setting parameter/ storage

*The parameter that has read-in from the file reflects to the writing column of list. *The parameter that stores in the file is the parameter of reading column of the list. Saving the file for trend graph data

*When the number of measuring points is “0”, you can’t read the graphic data. *After reading the data is over, specify the file name and store it. Input of Header information to control file

*“Serial No.”, “Memorandum” and “Version” are input through the software. Calibration by Communication (Electrical calibration)

*The items related to the calibration value (value of weighing capacity, scale interval (Minimum scale interval), registration of ZERO mV/V (Fourth digit of decimal point), registration of SPAN (Fourth digit of decimal point), position of decimal point, Unit, excitation, condition of OL display, gravity acceleration compensation method, district number of calibration place, district number of using place, gravity acceleration of calibration place, gravity acceleration of using place, registration of ZERO mV/V (Fifth digit of decimal point), registration of SPAN mV/V (Fifth digit of decimal point)) is made recordable, and the calibration by the communication is executed. *Writing of actual weight calibration (ZERO calibration and SPAN calibration) is set to prohibit.

Print function *The setting parameter is printed out. *The title, user name, device name, number, P/No., S/No., issued date and footer are enabled to be set arbitrarily, and output as a print item.

Calibration lock on the main body of CSD-912 *While locking the calibration (Hard lock or software lock) with the main body of CSD-912, you cannot

write the BASIC FUNCTION SETTING (Item for calibration lock), and execute the electrical calibration of [Calibration].

If above mentioned is executed, the error command is replied and the error message is displayed.

Page 5: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

5/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

2-3. Targeted insturmnts for operation Name of instrument Contents PC OS Windows XP

Windows Vista Windows 7 Windows 8.1 Windows 10

CPU 1GHz or more(recommended) Memory 512MB or more (recommended) Hard disk 1GB or more (recommended) Serial port 1 port

USB<->Serial transducer is usable. (recommended)

CD-ROM drive Required at the time of installation.

Mouse Suitable product to PC. Used in various kinds of operation. Key board Suitable product to PC. Used in various kinds of operation. Monitor Color display of resolution 1280×1024 (recommendation) Targeted indicator CSD-912 *Not corresponded to the CSD-912 prior to Ver.1.600.

(CSD-912-P74 as an option is required to use RS-232C.) USB<->Serial converter Converter for the communication between the PC and CSD-912(-74).

Recommended RS-232C : I・O DATA, USB-RSAQ5 RS-485 : LINEEYE, SI-35USB HUMANDATA, USB-003

RS-485 cable (2 wires method) The communication cable between the USB<->Serial converter and CSD-912.

2-4. Specifications for communication Corresponds to RS-422/485 and RS-232C.(*Specifications for communication correspond to CSD-912. Refer to the table below :)

specifications Contents Communication method Half-duplex

Synchronous method

Start stop synchronous method

Baud rate Selectable from 1 200bps,2 400bps,4 800bps,9 600bps,19 200bps or 38 400 bps.

Data bit length Selectable from 7 bit or 8 bit.

Parity bit Selection from none, even number parity or odd number parity.

Stop bit Selectable from 1 bit or 2 bit.

Terminator Selectable from CR+LF or CR. Transmission data ASCII code

Address Select one from 0 to 31. (Only when RS-422/485 is applied.)

Page 6: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

6/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

2-5. Connection 2-5-1. Connection of standard RS-485 interface

PC is connected with the A, B and S.G on the interface terminal of RS-485 of CSD-912, and makes use of it used in the Command mode.

2-5-2. Connection with the RS-232C interface sold separately

PC in connected with RS-232C connector on CSD-912-74, and used of it in the Command mode.

PC

Serial port

CSD-912-74 RS-232C

PC

USB

USB/RS-232C converter USB RS-232C

CSD-912-74 RS-232C

Straight cable

Straight cable

PC

USB

USB/RS-485 converter USB RS-485+

RS-485- S.G.

CSD-912 A B S.G

Page 7: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

7/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

2-6. Specifications for functions 2-6-1. Operation menu

(1) Main menu

HEADER (H) Set “Serial No.”, “Memorandum” and “ROM version”. WEIGHNG MODE(W) Changeover of the Measurement mode. Calibration(C) Changeover of the Calibration mode. *It displayed only when selected “CALIBRATION” at "Disp & Set Item". DISP & SET Display of parameter to be read, and set of parameter to write. Set the setting group at the time of display/set, and set the targeted code at the time of Brand and so on. DATA Order to read or write for the CSD-912. FILE Order to read or write for the file. Print(P) Order to print the date.

*As for reading the trend graph data, execute with the [Graph(G)] located on the Menu bar.

Page 8: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

8/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Communication setting menu

Port Set the number of serial port. Baud Rate Set the Baud rate. Parity Set the Parity bit. Stop Bit Set the Stop bit length. Term Set the Terminator. RS422/485 Set the use of declaration of RS422/485 interface and address. Time Out Set the Time out posed for communication.

Page 9: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

9/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(3) Print menu

Printer Set the printer. Form Set the form to print out. *Impossible to set. Print direction Set the direction to print. *Impossible to set. Printing contents Set the contents to be printed. Items in the list depend on the selection of the "WEIGHING MODE".

WEIGHING MODE list item Simple comparison mode “BRAND CODE”,

“RECIPE CODE”, “OPERATION SETTING”

Sequential mode “BRAND CODE”, “RECIPE CODE”, “OPERATION SETTING”

4 STEP COMPARATOR “4 STEP COMPARATOR”, “OPERATION SETTING”

Print Range Set the range to be printed. *Displayed only when we chose excluding "OPERATION SETTING". Print items Set the item to print out.

Page 10: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

10/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

2-6-2. File output Outputs the Header information to the file for the purpose of control.

*Outputs the Header to the parameter file and the trend graph file. The file format is CSV format. (Can be controlled with EXCEL or the Text editor.) User can save the file to the optional folder. The file name of Parameter is saved with “Optional name _para.CSV”.

EX) When the optional name is set as “CSD912 parameter”, the file name created is “CSD912 parameter _para.CSV”.

When the optional name is not ordered, save with “present time”, (YYYYMMDD_HHMMSS)_para.CSV」. EX) The date and time when creating the file is in the case of 9 o’clock 10 minute 12 sec on June 10 in 2009”, the file name shall be”20090610_091012_para.CSV”.

The trend graph name can be saved as “Optional name_graph.CSV”. EX) When the optional name is made as “CSD912 ***”, the file name shall be created as “CSD912***_graph.CSV”. When the optional name isn’t specified, make it as “present time (YYYYMMDD_HHMMSS)_graph.CSV”. EX) The present time when creating the file is at “2009June10, 09, 10, 12”, the file name shall be”20090610_091012_ graph.CSV “.

Page 11: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

11/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

The formats for each file are as follows:

Parameter file Model , CSD-912 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Memo , ABCDEFGHIJK Memorandum 0 , 999999999 , , 0,・・・・, 99 Related to Brand 100 brands×19 kinds 0 , 0 , Brand code , 0,・・・・, 0 0 , 1 , Brand name , 1,・・・・, 100 : : 0 , 17 , Initial Full Flow , 17,・・・・, 116 0 , 18 , Initial Medium Flow , 18,・・・・, 117 1 , 999999999 , , 0,・・・・, 99 Related to Recipe 100 Recipes×14 kinds 1 , 0 , Recipe Code , 1,・・・・, 1 1 , 1 , Name , 20,・・・・, 119 : : 1 , 12 , Recipe Accum Total , 31,・・・・, 130 1 , 13 , Recipe Accum Count , 32,・・・・, 131 2 , 999999999 , , 0,・・・・, 99 2 , 0 , Brand Code , 5,・・・・,5 Related to 4 steps comparator 100 Brands×18 kinds 2, 1 , Name , 40,・・・・, 139 : : 2 , 14 , Target of S3 Operation , 53,・・・・, 152 2 , 15 , Target of S4 Operation , 54,・・・・, 153 3 , 0 , Display times , 60 Related to fundamental function 3 , 1 , Set AD sampling rate , 61 : : 3 , 23 , Accum command , 83 3 , 24 , Print command , 84 4 , 0 , F1 key function , 90 4 , 1 , F2 key function , 91 : : 4 , 24 , I/O output 10 , 114 4 , 25 , I/O output 11 , 115 5 , 0 , Measurement mode , 120 Related to Measuring operation 5 , 1 , Control mode , 121 : : 5 , 48 , Condition of Auto Accum , 168 5 , 49 , Automatic Accum according to Recipe code , 169 6 , 0 , Start above zero band (B.S) , 170 Related to Sequence control 6 , 1 , Automatic Tare (B.S.) , 171 : : 6 , 30 , Mixing finish output ON(Recipe finish) , 200 6 , 31 , Mixing the Output ON(Recipe finish) , 201 7 , 0 , Zero Adjustment , 210 Related to Calibration 7 , 1 , Span Adjustment , 210 : : 7 , 15 , Calib. Place G.A. , 210 7 , 16 , Operation Place G.A. , 210 -1,-1,-1,-1 EOF

※ The file of setting parameter can’t be rewritten the data through the editor directly.

Page 12: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

12/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

Trend graph file Model , CSD-912 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Time , 50 Memorandum Point , 350 No. of data No. , Data 0 , 99999 Trend graph data 1 , 99999 2 , 99999 : : 348 , 99999 349 , 99999 EOF

*Specifications which have printed may subject to change for the purpose of improvement without notice.

Page 13: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

13/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

2-6-3. Print functions Print out the data read-in from the CSD-912 to the printer.

*Usable as a parameter sheet. As for the print items in below, optional character string can be set on the print menu.

Title, customer’s name, name of device, No., Model, S/N, published date and footer For the setting items other than the Compare values, * (asterisk) marks are applied.

However, * mark will not be applied to the “BRAND CODE Parameters” and “RECIPE CODE Parameters” .

The procedures of print format are as follows: [“Print Out Select" : ”BRAND CODE”] Title

Print information

Set for each BRAND CODE Setting

BRAND CODE Setting Print area

Footer

Page number

Page 14: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

14/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

[“Print Out Select" : ”RECIPE CODE”] Title

Print information

Set for each RECIPE CODE Setting

RECIPE CODE Setting Print area

Footer

Page number

Page 15: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

15/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

[“Print Out Select" : ” 4 STEP COMPARATOR”] Title

Print information

Set for each 4 STEP COMPARATOR Setting

4 STEP COMPARATOR Setting Print area

Footer

Page number

Page 16: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

16/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

[“Print Out Select" : ” OPERATION SETTING”] << First Page >> Title

Print information

Various settings Print area

Footer

Page number

Page 17: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

17/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

[“Print Out Select" : ” OPERATION SETTING”] << Second Page >>

Various settings Print area

Page 18: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

18/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

3.CSD-903D-01【Communication tool software for CSD-903】

3-1. General By sending/receiving the command between CSD-903 Digital Indicator and your personal computer, you can read the setting parameter of CSD-903 and also can write the optional setting parameter though this software. Moreover, the setting parameter that has read-in can be output to the file.

3-2. Software function The functions in this software possesses are as follows: Reading/Writing the setting parameter (All the items lump together, Individual)

*The parameters read-in are shown on the reading column of list. *Writing parameter is set on the writing column of list. *A parameter different form then compare value displays the set value in red. (Read and Write fields common.) * The Compare value is set from the file of the default value or the configuration parameter. *A parameter different form then initial value displays the set value in red. (Read and Write fields are common.)

*Related items for calibration values : (Increment value, Max. display value, Actual load value, Zero calibration value, Span calibration value) Related items of communication: (RS-232C selection of operation, RS-232C selection of output target, Communication setting, RS422/485 ID setting, Changeover of RS422/RS485, RS485 response delay time, Addition of decimal point, Operation of standard RS485) All of the above items are prohibited to write.

Reading and saving the file of setting parameter. *The parameter that read-in from the file reflects to the writing column of list. *The parameter that stores the file is the parameter of reading column of the list.

Input of Header information in order to control file *“Serial No.”, “Memorandum” and “Version” are input through the software.

Communication calibration (Electrical calibration) *The items related to the calibration value (Increment value, Max. display value, Actual load value, Zero calibration value and Span calibration value) is made recordable, and the calibration by the communication is executed.

Print function *The setting parameter is printed out. *The title, user name, device name, number, P/No., S/No., issued date and footer are enabled to be set arbitrarily, and output as a print item.

The data that can’t handle *The compensation data for digital liberalization can’t be read-in and written.

Calibration lock on the main body of CSD-903 *While locking the calibration (Hard lock or software lock) with the main body of CSD-903, you cannot write the data of CFunc by [All Write] and [Write], and execute the electrical calibration by [Calibration]. If above mentioned is executed, the error command is replied and the error message is displayed.

Page 19: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

19/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

3-3. Targeted instruments for operation Name of instrument Contents PC OS Windows XP

Windows Vista (32bit Version) Windows 7 (32bit Version)

CPU 1GHz or more (Recommendation)

Memory 512MB or more (Recommendation) Hard disk 1GB or more (Recommendation) Serial port 1 port

USB<->Serial converter is usable. (Recommendation)

CD-ROM drive Required at the time of installation.

Mouse Suitable product to PC. Used in various kinds of operation. Key board Suitable product to PC. Used in various kinds of operation. Monitor Color display of resolution 1280×1024 (Recommendation) Targeted indicator CSD-903

* CSD-903-P74 as an option is required to use RS-232C. USB<->serial converter The converter for the communication between the PC and

CSD-903(-74). Recommend RS-232C : I・O DATA, USB-RSAQ5 RS-485 : LINEEYE ,SI-35USB HUMANDATA, USB-003

RS-485 cable (2 wires method) The communication cable between the USB<->serial converter and CSD-903.

3-4. Specifications for communication Correspond to RS-422/485 and RS-232C. (*Specifications for communication correspond to CSD-903. Refer to the table below :)

Specifications Contents Communication method Half-duplex

Synchronous method Start stop synchronous method

Baud rate Selection from 1 200bps, 2 400bps, 4 800bps, 9 600bps,19 200bps or 38 400 bps.

Data bit length Selection from 7 bit or 8 bit.

Parity bit Selection from none, even number parity or odd number parity.

Stop bit Selection from 1 bit or 2 bit.

Terminator Selection from CR+LF or CR. Transmission data ASCII code

Address Select one from 0 to 31. (Only when RS-422/485 is used.)

Page 20: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

20/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

3-5. Connection 3-5-1. Connection with standard RS-485 interface

PC is connected with the A, B, and S.G. on the interface terminal of RS-485 of CSD-903, and make use of it used the Command mode.

3-5-2. Connection with RS-232C interface sold separately

PC is connected with RS-232C connector on CSD-903-74, and used in the Command mode.

PC

Serial port

CSD-903-74 RS-232C

PC

USB

USB/RS-232C converter USB RS-232C

CSD-903-74 RS-232C

Straight cable

Straight cable

PC

USB

USB/RS-485 converter USB RS-48+

RS-485-S.G.

CSD-903 A B S.G

Page 21: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

21/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

3-6. Specifications for functions 3-6-1. Operation menu

(1) Main menu

HEADER (H) Set “Serial No.”, “Memorandum” and “ROM version”. Calibration(C) Changeover of the Calibration mode. * It displayed only when selected “CFunc” at "Disp & Set Item". DISP & SET Display of parameter to be read, and set of parameter to write. Set the setting group at the time of display/set, and set the targeted code at the time of Brand and so on. DATA Order to read or write for the CSD-903. FILE Order to read or write for the file. Print Order to print the date.

Page 22: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

22/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Communication setting menu

Port Set the number of serial port BaudRate Set the Baud rate. Char Length Set the data bit length. Parity Set the Parity bit. Stop Bit Set the Stop bit length. Term Set the Terminator. RS422/485 Set the use of declaration of RS422/485 interface and address. Time Out Set the Time out for communication.

Page 23: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

23/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(3) Print menu

Printer Set the printer. Form Set the form to print out. *Impossible to set. Print direction Set the direction to print. *Impossible to set. Print items Set the item to print out.

3-6-2. File output Outputs the Header information to the file for the purpose of control.

*Outputs the Header on the parameter file. Format of the file is CSV format. (Controlled with EXCEL, and text editor.) Can be stored in the optional folder. Can be stored with “Optional name_para.CSV” as for the parameter file name.

EX) Suppose the optional name is set as “CSD903 ***”, the file name created shall be “CSD903 ***_para.CSV”.

If the optional name isn’t set, saved with the name of “present time YYYYMMDD_HHMMSS)_para.CSV”. EX) The present time when creating the file is at “2009June10,09,10,12”, the file name created shall be”20090610_091012_para.CSV”.

Page 24: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

24/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

The formats for each file are as follows:

Parameter file Model , CSD-903 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Memo , ABCDEFGHIJK Memorandum 0, 0, Digital filter, 16, Func 0, 1, Analog filter, 1, : : 0, 62, Maintenance day, 0, 0, 63, Maintenance No, 0, 1, 0, Decimal point, 0, CFunc 1, 1, AD sampling rate,1, 1, : : 1, 31, Span point mV/V, 10000, 1, 32, CAL.STAB.DETEC.TIME, 5, 2, 0, Measurement Mode, 1, SQFunc 2, 1, Control Mode, 0, : : 2, 27, DISCH. Finish output ON, 0, 2, 28, TARE Clear (D.F.A) 0, 3, 0, 4 step comparator 1_2:S1, 0, COMP 3, 1, 4 step comparator 1_2:S2, 0, : : 3, 11, Public: Full, 0, 3, 12, Public: Pre Tare, 0, -1, -1, -1, -1, EOF

※ The file of setting parameter can’t be rewritten the data directly through the editor.

Page 25: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

25/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

3-6-3. Print functions Print out the data read-in from the CSD-903 to the printer.

*Usable as a parameter sheet. As for the print items in below, optional character string can be set on the print menu.

Title, customer’s name, name of device, No., Model, S/N, published date and footer For the setting items other than the Compare values, * (asterisk) marks are applied. The procedures of print format are as follows:

<<First Page>>

Title Page number

Print information

CFunc

Footer

SQFunc

Func

Page 26: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

26/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

<<Second Page>>

COMP

Page 27: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

27/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

4.CSD-892-xxD-01【Communication tool software for CSD-892-xx】

4-1. General By sending/receiving the command between CSD-892-xx(CSD-892-73, CSD-892-74, CSD-892-76, CSD-892-07-25) Digital Conversion Module and your personal computer, you can read the setting parameter of CSD-892-xx and also can write the optional setting parameter though this software. Moreover, the setting parameter that has read-in can be output to the file.

4-2. Software function The functions in this software possesses are as follows: Reading/Writing the setting parameter (All the items lump together, Individual)

*The parameters read-in are shown on the reading column of list. *Writing parameter is set on the writing column of list. *A parameter different form then compare value displays the set value in red. (Read and Write fields common.) * The Compare value is set from the file of the default value or the configuration parameter. *Related items for calibration values : (Increment value, Max. display value, Actual load value, Zero calibration value, Span calibration value) Related items of communication: (RS-232C selection of operation, RS-232C selection of output target, Communication setting, Addition of decimal point) All of the above items are prohibited to write.

Reading and saving the file of setting parameter.

*The parameter that read-in from the file reflects to the writing column of list. *The parameter that stores the file is the parameter of reading column of the list.

Input of Header information in order to control file *“Serial No.”, “Memorandum” and “Version” are input through the software.

Calibration by Communication (Electrical calibration) *The items related to the calibration value (Increment value, Max. display value, Actual load value, Zero calibration value and Span calibration value) is made recordable, and the calibration by the communication is executed.

Print function *The setting parameter is printed out. *The title, user name, device name, number, P/No., S/No., issued date and footer are enabled to be set arbitrarily, and output as a print item.

The data that can’t handle

*The compensation data for digital liberalization can’t be read-in and written.

Calibration lock on the main body of CSD-892-xx *While locking the calibration (Hard lock or software lock) with the main body of CSD-892-xx, you cannot write the data of CFunc by [All Write] and [Write], and execute the electrical calibration by [Calibration]. If above mentioned is executed, the error command is replied and the error message is displayed. .

Page 28: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

28/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

4-3. Targeted instruments for operation Name of instrument Contents PC OS Windows XP

Windows Vista (32bit Version) Windows 7(32bit Version)

CPU 1GHz or more (Recommendation)

Memory 512MB or more (Recommendation) Hard disk 1GB or more (Recommendation) USB port 1 port CD-ROM drive Required at the time of installation.

Mouse Suitable product to PC. Used in various kinds of operation. Key board Suitable product to PC. Used in various kinds of operation. Monitor Color display of resolution 1280×1024 (Recommendation) Targeted indicator CSD-892-73,CSD-892-74,CSD-892-76,CSD-892-07-25 USB cable USB A type plug to USB Mini-B type plug.

4-4. Specifications for communication Correspond to RS-232C. (*Specifications for communication correspond to CSD-892-xx. Refer to the table below :)

Specifications Contents Communication method Half-duplex

Synchronous method Start stop synchronous method

Baud rate Selection from 1 200bps, 2 400bps, 4 800bps, 9 600bps,19 200bps or 38 400 bps.

Data bit length Selection from 7 bit or 8 bit.

Parity bit Selection from none, even number parity or odd number parity.

Stop bit Selection from 1 bit or 2 bit.

Terminator Selection from CR+LF or CR. Transmission data ASCII code

Page 29: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

29/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

4-5. Connection 4-5-1. Connection with USB interface

PC is connected with USB connector on CSD-892-xx, and used in the EzCTS mode.

PC

USB port

CSD-892-xx USB(RS-232C)

USB cable

Page 30: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

30/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

4-6. Specifications for functions 4-6-1. Operation menu

(1) Main menu

HEADER (H) Set “Serial No.”, “Memorandum” and “ROM version”. Calibration(C) Changeover of the Calibration mode. * It displayed only when selected “CFunc” at "Disp & Set Item". DISP & SET Display of parameter to be read, and set of parameter to write. Set the setting group at the time of display/set, and set the targeted code at the time of Brand and so on. DATA Order to read or write for the CSD-892-xx. FILE Order to read or write for the file. Print Order to print the date.

Page 31: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

31/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Communication setting menu

Port Set the number of serial port BaudRate Set the Baud rate. Char Length Set the data bit length. Parity Set the Parity bit. Stop Bit Set the Stop bit length. Term Set the Terminator. RS422/485 Set the use of declaration of RS422/485 interface and address. Time Out Set the Time out for communication.

Page 32: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

32/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(3) Print menu

Printer Set the printer. Form Set the form to print out. *Impossible to set. Print direction Set the direction to print. *Impossible to set. Print items Set the item to print out.

4-6-2. File output Outputs the Header information to the file for the purpose of control.

*Outputs the Header on the parameter file. Format of the file is CSV format. (Controlled with EXCEL, and text editor.) Can be stored in the optional folder. Can be stored with “Optional name_para.CSV” as for the parameter file name.

EX) Suppose the optional name is set as “CSD892-73 ***”, the file name created shall be “CSD892-73 ***_para.CSV”.

If the optional name isn’t set, saved with the name of “present time YYYYMMDD_HHMMSS)_para.CSV”. EX) The present time when creating the file is at “2009June10,09,10,12”, the file name created shall be”20090610_091012_para.CSV”.

Page 33: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

33/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

The formats for each file are as follows:

Parameter file Model , CSD-892-73 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Memo , ABCDEFGHIJK Memorandum 0, 0, Digital filter, 16, Func 0, 1, Analog filter, 1, : : 0, 34, MAINTENANCE NO, 0, 0, 35, BACK LIGHT OFF TIME, 0, 1, 0, Decimal point, 0, CFunc 1, 1, AD sampling rate,1, 1, : : 1, 23, Span point mV/V, 10000, 1, 24, CAL.STAB.DETEC.TIME, 5, 2, 0, Measurement Mode, 1, SQFunc 2, 1, Control Mode, 0, : : 2, 3, NEAR BAND COMP.OPER., 0, 2, 4, COMP. OF FULL OPER., 0, 3, 0, 5 step comparator :S0, 0, COMP 3, 1, 5 step comparator :S1, 0, : : 3, 11, Public: Full, 0, 3, 12, Public: Pre Tare, 0, -1, -1, -1, -1, EOF

※ The file of setting parameter can’t be rewritten the data directly through the editor.

Page 34: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

34/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

4-6-3. Print functions Print out the data read-in from the CSD-892-xx to the printer.

*Usable as a parameter sheet. As for the print items in below, optional character string can be set on the print menu.

Title, customer’s name, name of device, No., Model, S/N, published date and footer For the setting items other than the Compare values, * (asterisk) marks are applied. The procedures of print format are as follows:

Title

Print information

CFunc

SFunc

Func

COMP

Page number

Page 35: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

35/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

5.CSD-893-76D-01【Communication tool software for CSD-893-76】

5-1. General By sending/receiving the command between CSD-893-76 Digital Conversion Module and your personal computer, you can read the setting parameter of CSD-893-76 and also can write the optional setting parameter though this software. Moreover, the setting parameter that has read-in can be output to the file.

5-2. Software function The functions in this software possesses are as follows: Reading/Writing the setting parameter (All the items lump together, Individual)

*The parameters read-in are shown on the reading column of list. *Writing parameter is set on the writing column of list. *A parameter different form then compare value displays the set value in red. (Read and Write fields common.) * The Compare value is set from the file of the default value or the configuration parameter. *Related items for calibration values : (Increment value, Max. display value, Actual load value, Zero calibration value, Span calibration value) Related items of communication: (RS-232C selection of operation, RS-232C selection of output target, Communication setting, Addition of decimal point) All of the above items are prohibited to write.

Reading and saving the file of setting parameter.

*The parameter that read-in from the file reflects to the writing column of list. *The parameter that stores the file is the parameter of reading column of the list.

Input of Header information in order to control file *“Serial No.”, “Memorandum” and “Version” are input through the software.

Calibration by Communication (Electrical calibration) *The items related to the calibration value (Increment value, Max. display value, Actual load value, Zero calibration value and Span calibration value) is made recordable, and the calibration by the communication is executed.

Print function *The setting parameter is printed out. *The title, user name, device name, number, P/No., S/No., issued date and footer are enabled to be set arbitrarily, and output as a print item.

The data that can’t handle

*The compensation data for digital liberalization can’t be read-in and written.

Calibration lock on the main body of CSD-893-76 *While locking the calibration (Hard lock or software lock) with the main body of CSD-893-76, you cannot write the data of CFunc by [All Write] and [Write], and execute the electrical calibration by [Calibration]. If above mentioned is executed, the error command is replied and the error message is displayed. .

Page 36: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

36/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

5-3. Targeted instruments for operation Name of instrument Contents PC OS Windows XP

Windows Vista (32bit Version) Windows 7(32bit Version)

CPU 1GHz or more (Recommendation)

Memory 512MB or more (Recommendation) Hard disk 1GB or more (Recommendation) USB port 1 port CD-ROM drive Required at the time of installation.

Mouse Suitable product to PC. Used in various kinds of operation. Key board Suitable product to PC. Used in various kinds of operation. Monitor Color display of resolution 1280×1024 (Recommendation) Targeted indicator CSD-893-76 USB cable USB A type plug to USB Mini-B type plug.

5-4. Specifications for communication Correspond to RS-232C. (*Specifications for communication correspond to CSD-893-76. Refer to the table below :)

Specifications Contents Communication method Half-duplex

Synchronous method Start stop synchronous method

Baud rate Selection from 1 200bps, 2 400bps, 4 800bps, 9 600bps,19 200bps or 38 400 bps.

Data bit length Selection from 7 bit or 8 bit.

Parity bit Selection from none, even number parity or odd number parity.

Stop bit Selection from 1 bit or 2 bit.

Terminator Selection from CR+LF or CR. Transmission data ASCII code

Page 37: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

37/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

5-5. Connection 5-5-1. Connection with USB interface

PC is connected with USB connector on CSD-893-76, and used in the EzCTS mode.

PC

USB port

CSD-893-76 USB(RS-232C)

USB cable

Page 38: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

38/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

5-6. Specifications for functions 5-6-1. Operation menu

(1) Main menu

HEADER (H) Set “Serial No.”, “Memorandum” and “ROM version”. Calibration(C) Changeover of the Calibration mode. * It displayed only when selected “CFunc” at "Disp & Set Item". DISP & SET Display of parameter to be read, and set of parameter to write. Set the setting group at the time of display/set, and set the targeted code at the time of Brand and so on. DATA Order to read or write for the CSD-893-76. FILE Order to read or write for the file. Print Order to print the date.

Page 39: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

39/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Communication setting menu

Port Set the number of serial port BaudRate Set the Baud rate. Char Length Set the data bit length. Parity Set the Parity bit. Stop Bit Set the Stop bit length. Term Set the Terminator. RS422/485 Set the use of declaration of RS422/485 interface and address. Time Out Set the Time out for communication.

Page 40: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

40/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(3) Print menu

(4) Printer Set the printer. Form Set the form to print out. *Impossible to set. Print direction Set the direction to print. *Impossible to set. Print items Set the item to print out.

5-6-2. File output Outputs the Header information to the file for the purpose of control.

*Outputs the Header on the parameter file. Format of the file is CSV format. (Controlled with EXCEL, and text editor.) Can be stored in the optional folder. Can be stored with “Optional name_para.CSV” as for the parameter file name.

EX) Suppose the optional name is set as “CSD893-76 ***”, the file name created shall be “CSD893-76 ***_para.CSV”.

If the optional name isn’t set, saved with the name of “present time YYYYMMDD_HHMMSS)_para.CSV”. EX) The present time when creating the file is at “2009June10,09,10,12”, the file name created shall be”20090610_091012_para.CSV”.

Page 41: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

41/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

The formats for each file are as follows:

Parameter file Model , CSD-893-76 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Memo , ABCDEFGHIJK Memorandum 0, 0, Digital filter, 16, Func 0, 1, Analog filter, 1, : : 0, 34, MAINTENANCE NO, 0, 0, 35, BACK LIGHT OFF TIME, 0, 1, 0, Decimal point, 0, CFunc 1, 1, AD sampling rate,1, 1, : : 1, 23, Span point mV/V, 10000, 1, 24, CAL.STAB.DETEC.TIME, 5, 2, 0, Measurement Mode, 1, SQFunc 2, 1, Control Mode, 0, : : 2, 3, NEAR BAND COMP.OPER., 0, 2, 4, COMP. OF FULL OPER., 0, 3, 0, 5 step comparator :S0, 0, COMP 3, 1, 5 step comparator :S1, 0, : : 3, 11, Public: Full, 0, 3, 12, Public: Pre Tare, 0, -1, -1, -1, -1, EOF

※ The file of setting parameter can’t be rewritten the data directly through the editor.

Page 42: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

42/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

5-6-3. Print functions Print out the data read-in from the CSD-893-76 to the printer.

*Usable as a parameter sheet. As for the print items in below, optional character string can be set on the print menu.

Title, customer’s name, name of device, No., Model, S/N, published date and footer For the setting items other than the Compare values, * (asterisk) marks are applied. The procedures of print format are as follows:

Title

Print information

CFunc

SFunc

Func

COMP

Page number

Page 43: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

43/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

6.CSD-918D-02【Communication tool software for CSD-918】

6-1. General By sending/receiving the commands between the Servo weighing controller CSD-918 and your Personal computer, the software can read-in the setting parameter/trend graphic data of CSD-918 and also write the optional parameter to CSD-918. Moreover, setting parameter that has read-in and the trend graphic data can be output to the file.

6-2. Software functions The functions in this software are as follows: Reading/Writing the setting parameter (All the items in the batch)

*Display the read-in parameter to the reading column of the list. *Set the written parameter to the writing column of the list. *A parameter different form then compare value displays the set value by a red character. (Read and Write fields are common.) * The Compare value sets the file of the default value or the configuration parameter. *The following items are prohibited from writing. ・Items related to the calibration value (Increment value, maximum display value, actual load value, zero calibration value, span calibration value) ・Items related to the communication (selection of RS-232C operation, selection of RS-232C output target, communication setting, ID setting of RS-422/485, switch between RS-422 and RS-485, reply delay time of RS-485, decimal point addition and standard RS-485 operation) Reading and saving file of setting parameter

*The parameter that has read-in from the file reflects to the writing column of the list. *The parameter that stores in the file is the parameter of reading column of the list. Saving the file for trend graph data

*When the number of measuring points is “0”, you can’t read the graphic data. *Specify the file name after completing the data reading and save the file. Input of Header information to aim at file management.

*“Serial No.”, “Memorandum” and “Version” are input with this software. Calibration by Communication (Electrical calibration)

*Turn the following items recordable and execute the calibration by communicaion. ・Items related to the calibration value (value of weighing capacity, scale interval (Minimum scale interval),

registration of ZERO mV/V (Five digits after the decimal point), registration of SPAN (Five digits after the decimal point), position of decimal point, Unit, excitation, condition of OL display, gravity acceleration compensation method, district number of calibration place, district number of using place, gravity acceleration of calibration place, gravity acceleration of using place).

*Writing of actual weight calibration value (ZERO calibration and SPAN calibration) is set to prohibit. Print function

*The setting parameter is printed out. *The title, user name, device name, number, P/No., S/No., issued date and footer are enabled to be set arbitrarily, and output as a print item.

Calibration lock on the main body of CSD-918 *While locking the calibration (Hard lock or software lock) with the main body of CSD-918, you cannot

write the BASIC FUNCTION SETTING (Item for calibration lock), and execute the electrical calibration of [Calibration].

If above mentioned is executed, the error command is replied and the error message is displayed.

Page 44: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

44/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

6-3. Targeted insturmnts for operation Name of instrument Contents PC OS Windows XP

Windows Vista (32bit Version) Windows 7(32bit Version)

CPU 1GHz or more(recommended) Memory 512MB or more (recommended) Hard disk 1GB or more (recommended) Serial port 1 port

USB<->Serial transducer is usable. (recommended)

CD-ROM drive Required at the time of installation.

Mouse Suitable product to PC. Used in various kinds of operation. Key board Suitable product to PC. Used in various kinds of operation. Monitor Color display of resolution 1280×1024 (recommendation) Targeted indicator CSD-918

(CSD-918-P74 as an option is required to use RS-232C.) USB<->Serial converter Converter for the communication between the PC and CSD-918(-74).

Recommended RS-232C : I・O DATA, USB-RSAQ5 RS-485 : LINEEYE, SI-35USB HUMANDATA, USB-003

RS-485 cable (2 wires method) The communication cable between the USB<->Serial converter and CSD-918.

6-4. Specifications for communication Corresponds to RS-422/485 and RS-232C.(*Specifications for communication correspond to CSD-918. Refer to the table below :)

Specifications Contents Communication method Half-duplex

Synchronous method Start stop synchronous method

Baud rate Selectable from 1 200bps,2 400bps,4 800bps,9 600bps,19 200bps or 38 400 bps.

Data bit length Selectable from 7 bit or 8 bit.

Parity bit Selection from none, even number parity or odd number parity.

Stop bit Selectable from 1 bit or 2 bit.

Terminator Selectable from CR+LF or CR.

Transmission data ASCII code

Address Select one from 0 to 31. (Only when RS-422/485 is applied.)

Page 45: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

45/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

6-5. Connection 6-5-1. Connection of standard RS-485 interface

PC is connected with the A, B and S.G on the interface terminal of RS-485 of CSD-918, and uses it in the Command mode.

6-5-2. Connection with the RS-232C interface sold separately

PC is connected with RS-232C connector on CSD-918-74, and uses it in the Command mode.

PC

Serial port

CSD-918-74 RS-232C

PC

USB

USB/RS-232C converter USB RS-232C

CSD-918-74 RS-232C

Straight cable

Straight cable

PC

USB

USB/RS-485 converter USB RS-485+

RS-485- S.G.

CSD-918 A B S.G

Page 46: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

46/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

6-6. Specifications for functions 6-6-1. Operation menu

(1) Main menu

MAX CODE Set the maximum numbers of brand to be used. Selectable from 5,10,20 or 100 HEADER (H) Set “Serial No.”, “Memorandum” and “ROM version”. Calibration(C) Change of the Calibration mode. *It displayed only when selected “CALIBRATION” at "Disp & Set Item". DISP & SET Display of parameter to be read, and set of parameter to write. Set the setting group at the time of display/set, and set the targeted code at the time of Brand and so on. DATA Order to read or write for the CSD-918. FILE Order to read or write for the file. Print(P) Order to print the date.

*As for reading the trend graph data, execute with the [Graph(G)] located on the Menu bar.

Page 47: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

47/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Communication setting menu

Port Set the number of serial port. Baud Rate Set the Baud rate. Parity Set the Parity bit. Stop Bit Set the Stop bit length. Term Set the Terminator. RS422/485 Set the use of declaration of RS422/485 interface and address. Time Out Set the Time out posed for communication.

Page 48: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

48/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(3) Print menu

Printer Set the printer. Form Set the form to print out. *Impossible to set. Print direction Set the direction to print. *Impossible to set. Printing contents Set the contents to be printed. Selected from the "BRAND CODE ", "OPERATION SETTING ". Print Range Set the range to be printed. *Displayed only when we chose excluding "OPERATION SETTING". Print items Set the item to print out.

Page 49: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

49/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

6-6-2. File output Outputs the Header information to the file to manage.

*Outputs the Header to the parameter file and the trend graph file. The file is CSV format. (Can be managed with EXCEL or the text editor.) User can save the file to the optional folder. The file name of Parameter is saved with “Optional name _para.CSV”.

EX) When the optional name is set as “CSD918 parameter”, the file name created is “CSD918 parameter _para.CSV”.

When the optional name is not ordered, save with “present time”, (YYYYMMDD_HHMMSS)_para.CSV」. EX) The date and time when creating the file is in the case of 9 o’clock 10 minute 12 sec on June 10 in 2009”, the file name shall be”20090610_091012_para.CSV”.

The trend graph name can be saved as “Optional name_graph.CSV”. EX) When the optional name is made as “CSD918 ***”, the file name shall be created as “CSD918***_graph.CSV”. When the optional name isn’t specified, make it as “present time (YYYYMMDD_HHMMSS)_graph.CSV”. EX) The present time when creating the file is at “2009June10, 09, 10, 12”, the file name shall be”20090610_091012_ graph.CSV “.

Page 50: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

50/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

The formats for each file are as follows:

Parameter file Model , CSD-918 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Memo , ABCDEFGHIJK Memorandum 0 , 999999999 , , 0,・・・・, 99 Related to Brand 100 brands×137kinds 0 , 0 , Brand code , 0,・・・・, 0 0 , 1 , Brand name , 1,・・・・, 100 : : 0 , 135 , BRAND ACCUM. TIMES ,135,・・・・,144, 0 , 136 , PRESET TARE ,136,・・・・,145 3 , 0 , DISP. REFRESH RATE ,1 , Related to fundamental function 3 , 1 , A/D SAMPLING RATE ,5, : : 3 , 30 , S-I/F HOLD ,2, 3 , 31 , LOAD DISP. VALUE HOLD ,1, 4 , 0 , FUNCTION OF F1 KEY ,1, , Related to input and output 4 , 1 , FUNCTION OF F2 KEY ,1, : : 4 , 34 , CALIBRATION KEY LOCK ,2, 4 , 35 , SERVO CALIB. KEY LOCK ,2, 5 , 0 , CONTROL MODE ,1, Related to Measuring operation 5 , 1 , COMPARISION ,3, : : 5 , 38 , CONDITION OF AUTO ACM. ,2, 5 , 39 , AUTOMATIC PRINT ,2, 6 , 0 , START ABOVE ZERO BAND ,2, Related to Sequence control 6 , 1 , AUTOMATIC TARE ,2, : : 6 , 25 , MIXING FINISH OUTPUT ON ,0, 6 , 26 , MIXING THE OUTPUT ON ,0, 7 , 0 , ZERO ADJUSTMENT ,0, Related to Calibration 7 , 1 , SPAN ADJUSTMENT ,10000, : : 7 , 13 , CALIB. PLACE G.A. ,9797, 7 , 14 , OPERATION PLACE G.A. ,9797, 8 , 0 , RATED MOTOR SPEED ,3000, Servo Calibration 8 , 1 , MAX. INPUT PULSE FREQ. ,1000000, : : 8 , 16 , ORIGIN SENSOR ,2, 8 , 17 , READY FOR OPERATION ,2, -1,-1,-1,-1 EOF

※ The file of setting parameter can’t be rewritten the data through the editor directly.

Page 51: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

51/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

Trend graph file Model , CSD-918 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Time , 50 Memorandum Point , 350 No. of data No. , Data 0 , 99999 Trend graph data 1 , 99999 2 , 99999 : : 348 , 99999 349 , 99999 EOF

*Specifications which have printed may subject to change for the purpose of improvement without notice.

Page 52: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

52/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

6-6-3.Print functions Print out the data read-in from the CSD-918 to the printer.

*Usable as a parameter sheet. As for the print items in below, optional character string can be set on the print menu.

Title, customer’s name, name of device, No., Model, S/N, published date and footer For the setting items other than the Compare values, * (asterisk) marks are applied.

However, * mark will not be applied to the “BRAND CODE Parameters” and “RECIPE CODE Parameters” .

The procedures of print format are as follows: [“Print Out Select" : ”BRAND CODE”]

Title

Print information

Set for each BRAND CODE Setting

Footer

Page number

Page 53: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

53/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

[“Print Out Select" : ” OPERATION SETTING”] << First Page >>

Title

Print information

Various settings Print area

Footer

Page number

Page 54: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

54/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

[“Print Out Select" : ” OPERATION SETTING”] << Second Page >>

Various settings Print area

Page 55: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

55/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

7.CSD-709D-02【Communication tool software for CSD-709】

7-1.General By sending/receiving the commands between the Digital Peak Holder CSD-709 and your Personal computer, the software can read-in the setting parameter/trend graphic data of CSD-709 and also write the optional parameter to CSD-709. Moreover, setting parameter that has read-in and the trend graphic data can be output to the file.

7-2.Software function The functions in this software possesses are as follows: Reading/Writing the setting parameter (All the items lump together, Individual)

*The parameters read-in are shown on the reading column of list. *Writing parameter is set on the writing column of list. *A parameter different form then compare value displays the set value in red. (Read and Write fields common.) * The Compare value is set from the file of the default value or the configuration parameter. *Related items for calibration values : (Increment value, Max. display value, Actual load value, Zero calibration value, Span calibration value) Related items of communication: (RS-232C selection of operation, RS-232C selection of output target, Communication setting, Addition of decimal point) All of the above items are prohibited to write.

Reading and saving the file of setting parameter.

*The parameter that read-in from the file reflects to the writing column of list. *The parameter that stores the file is the parameter of reading column of the list.

Input of Header information in order to control file *“Serial No.”, “Memorandum” and “Version” are input through the software.

Calibration by Communication (Electrical calibration) *The items related to the calibration value (Increment value, Max. display value, Actual load value, Zero calibration value and Span calibration value) is made recordable, and the calibration by the communication is executed.

Print function *The setting parameter is printed out. *The title, user name, device name, number, P/No., S/No., issued date and footer are enabled to be set arbitrarily, and output as a print item.

Page 56: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

56/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

7-3.Targeted instruments for operation

Name of instrument Contents PC OS Windows XP

Windows Vista (32bit Version) Windows 7(32bit Version)

CPU 1GHz or more (Recommendation)

Memory 512MB or more (Recommendation) Hard disk 1GB or more (Recommendation) USB port 1 port CD-ROM drive Required at the time of installation.

Mouse Suitable product to PC. Used in various kinds of operation. Key board Suitable product to PC. Used in various kinds of operation. Monitor Color display of resolution 1280×1024 (Recommendation) Targeted indicator CSD-709 USB cable USB A type plug to USB Mini-B type plug.

7-4.Specifications for communication Correspond to RS-232C. (*Specifications for communication correspond to CSD-709. Refer to the table below :)

Specifications Contents Communication method Half-duplex

Synchronous method Start stop synchronous method

Baud rate Selection from 1 200 bps, 2 400 bps, 4 800 bps, 9 600 bps, 19 200 bps, 38 400 bps or 115 200 bps.

Data bit length Selection from 7 bit or 8 bit.

Parity bit Selection from none, even number parity or odd number parity.

Stop bit Selection from 1 bit or 2 bit.

Terminator Selection from CR+LF or CR. Transmission data ASCII code

7-5.Connection 7-5-1. Connection with USB interface

PC is connected with USB connector on CSD-709, and used in the EzCTS mode.

PC

USB port

CSD-709 USB(RS-232C)

USB cable

Page 57: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

57/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

7-6.Specifications for functions 7-6-1. Operation menu

(1) Main menu

HEADER (H) Set “Serial No.”, “Memorandum” and “ROM version”. Calibration(C) Changeover of the Calibration mode. * It displayed only when selected “CFunc” at "Disp & Set Item". DISP & SET Display of parameter to be read, and set of parameter to write. Set the setting group at the time of display/set, and set the targeted code at the time of Brand and so on. DATA Order to read or write for the CSD-709. FILE Order to read or write for the file. Print Order to print the date.

Page 58: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

58/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(2) Communication setting menu

Port Set the number of serial port BaudRate Set the Baud rate. Char Length Set the data bit length. Parity Set the Parity bit. Stop Bit Set the Stop bit length. Term Set the Terminator. RS422/485 Set the use of declaration of RS422/485 interface and address. Time Out Set the Time out for communication.

Page 59: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

59/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

(3) Print menu

Printer Set the printer. Form Set the form to print out. *Impossible to set. Print direction Set the direction to print. *Impossible to set. Print items Set the item to print out.

7-6-2.File output Outputs the Header information to the file for the purpose of control.

*Outputs the Header on the parameter file. Format of the file is CSV format. (Controlled with EXCEL, and text editor.) Can be stored in the optional folder. Can be stored with “Optional name_para.CSV” as for the parameter file name.

EX) Suppose the optional name is set as “CSD709, the file name created shall be “CSD709_para.CSV”.

If the optional name isn’t set, saved with the name of “present time YYYYMMDD_HHMMSS)_para.CSV”. EX) The present time when creating the file is at “2009June10,09,10,12”, the file name created shall be”20090610_091012_para.CSV”.

Page 60: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

60/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

The formats for each file are as follows: Parameter file Model, CSD-709 Model Serial No , 123 Serial No. Ver , 1.000 ROM version Memo , ABCDEFGHIJK Memorandum 0, 0, Digital filter, 16, Func 0, 1, Analog filter, 7, : : 0,57, MAINTENANCE DAY, 0, 0,58, MAINTENANCE NO., 0, 1,0, CAL.1 DECIMAL POINT, 0, CFunc 1,1, A/D SAMPLING RATE, 2, : : 1,41, CAL.4 ZERO POINT MV/V, 0, 1,42, CAL.4 SPAN POINT MV/V, 5000, 2,0, DETECTING MODE, 0, PFunc 2,1, SPECIFIED SECTION, 0, : : 9,26, UPPER LIMIT VALUE, 99999, 9,27, LOWER LIMIT VALUE, -99999, 10,0, S0, 0, COMP 10,1, S1, 0, -1, -1, -1, -1, EOF

※ The file of setting parameter can’t be rewritten the data directly through the editor.

Page 61: Specifications EzCTS - minebea-mcd.com · Specifications EzCTS Communication Tool Software MinebeaMitsumi Inc., Sensing Device Business Unit 2-6-2. File output Outputs the Header

Revised in Feb. 2017

61/61Spec. No.EN382EzCTS-J

EzCTS SpecificationsCommunication Tool Software

MinebeaMitsumi Inc., Sensing Device Business Unit

7-6-3.Print functions Print out the data read-in from the CSD-709 to the printer.

*Usable as a parameter sheet. As for the print items in below, optional character string can be set on the print menu.

Title, customer’s name, name of device, No., Model, S/N, published date and footer For the setting items other than the Compare values, * (asterisk) marks are applied. The procedures of print format are as follows:

Title

Print information

Setting value

Page number

Footer