specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86...

8
specialty compounds FOR WIRE & CABLE

Transcript of specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86...

Page 1: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

specialty compounds FOR WIRE & CABLE

Page 2: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Cable Compounds

2

abrasion-resistant

flame-retardant

flexible flex. at low temperature

halogen-free

high temp.-resistant

low-smoke

oil-resistant

Product groups

Explanations

Features of Mecoline compounds Features of FM compounds

Compound experts Melos and Inhol join their forcesPremium specialty and economic commodity compounds, integrated R&D team and lean manufacturing.

Marcus HohlweckBusiness Unit ManagerCable Compounds

coilable(drumable)

migrationstabilised

tandemprocess

General

InstallationOffshore,Shipboard

Green EnergySolar

Marine, Aerospace,Defence

Rolling StockRapid Transit

Railways

Automotive

Applications

Thermo-plastic

Moisture crosslinkable

Radiationcrosslinkable

Peroxidecrosslinkable

Beddingcompounds

Sheathing / Insulation - „Mecoline“ compounds

synergy at work specialty compounds for wire & cable

Cooperation with Melos GmbH, experienced German compounderMelos GmbH in Germany and Inhol B.V. in The Netherlands have entered into a strategic partnership agreement to expand their delivery programs. By signing this agreement both companies will be able to market a wi-der range of compounds to the Wire & Cable industry. Through this new agreement Melos and Inhol intend to explore the synergies between the two companies in the field of compound technology and product develop-ment. Both companies have earned the trust of leading wire and cable manufacturers around the world. Together Melos and Inhol will utilize the MECOLINE brand name and harness a team of specialists to design, manufacture and market innovative MECOLINE compounds.

Compounds for Wire & Cables.Inhol BV/PTL has the ability to develop new compounds for relatively small volumes. The driving force behind the company is the active pur-suit of innovative product development for markets like solar/photovoltaic, aerospace, defence, shipboard, marine, off shore, rapid transit (rolling stock) and other industries. The range of compounds include LSFOH, thermoplastic, radiation and moisture cross linkable as well as some CV curable materials. All compounds are meeting the RoHS and REACH di-rectives. Inhol BV/PTL is an ISO 9001 and ISO 14001 certified company.

visit www.inhol.com for more information

Page 3: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Cable Compounds

3

Ope

rati

ng

tem

pera

ture

[°C

]

Sho

re h

ardn

ess

Tens

ile

stre

ngth

[N/m

m2]

Elo

ngat

ion

at b

reak

[%]

LOI

[%]

Den

sity

[g/

cm³]

Oil r

esis

tanc

e le

vel

Special Features Standards Application

Mecoline IS TP 1002 F

-30 to 90

55 D 11,0 175 37 1,58

BS 6724, BS 7655 part 6.1 LTS 2, DIN VDE 0276-604 HM4, DIN VDE 0281 part 14 TI6, DIN VDE 0281 part 14 TM7, EN 50363-7 TI6, EN 50363-7 TI7, EN 50363-8 TM7, IEC 60092-359 SHF1, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5

General Installation

Mecoline S TP 1003 F

-25 to 90

53 D 11,5 200 40 1,57very flame-retardant

BS 6724, BS 7655 part 6.1 LTS 2, CEI 20-11 M1, DIN VDE 0276-604 HM4, DIN VDE 0281 part 14 TM7, EN 50363-8 TM7, IEC 60092-359 SHF1, NF C 32-323, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5

General Installation

Mecoline S TP 1006 F

-25 to 90

50 D 10,0 175 45 1,56very flame-retardant

BS 6724, BS 7655 part 6.1 LTS 2, CEI 20-11 M1, DIN VDE 0276-604 HM4, DIN VDE 0281 part 14 TM7, EN 50363-8 TM7, IEC 60092-359 SHF1, NF C 32-323, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5

General Installation

Mecoline S TP 1013 F

-50

to

90

89 A 10,5 300 38 1,61very flame-retardant

oil-resistant

flex. (at lowtemperature)

DIN VDE 0276-604 HM4, DIN VDE 0281 part 14 TM7, EN 50363-8 TM7, IEC 60092-359 SHF1, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5

Green Energy/Offshore

Mecoline S TP 1021 F

-30to 80

48 D 10,5 225 42 1,48very flame-retardant

BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, DIN VDE 0281 part 14 TM7, EN 50363-8 TM7, IEC 60092-359 SHF1, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5

General Installation

Mecoline IS TP 1022 FNHFR-DA 21638 NT

-25to90

89 A 12,0 180 39 1,50very flame-retardant

IEEE 383, UL 1581 - 1080, UL 1685, UL 44 - VW-1

General Installation

Thermoplastic, halogen-free insulation and sheathing compounds

Ope

rati

ng

tem

pera

ture

[°C

]

Sho

re h

ardn

ess

Tens

ile

stre

ngth

[N/m

m2]

Elo

ngat

ion

at b

reak

[%]

LOI

[%]

Den

sity

[g/

cm³]

Oil r

esis

tanc

e le

vel

Special Features Standards Application

Mecoline IS MX 1403 F

MX 20325

-15 to

10547 D 14,5 200 31 1,42

EN 50363 EI5, EN 50363 EI8, EN 50363 EM 10, EN 50363 G10, EN 50363 G9, IEC 60092-351 HF90, VDE 0207 part 23 HJ1, VDE 0207 part 24 HM1, VDE 0250 part 215 HM5, VDE 0266 HXI1/HXM1

General Installation

Mecoline IS MX 1404 F

MX 20340

-40 to

12036 D 13,0 275 31 1,34

EN 50363 EI8, EN 50363 EM 10, EN 50363 G10, IEC 60092-351 HF90, VDE 0207 part 23 HJ1, VDE 0207 part 24 HM1, VDE 0250 part 215 HM5, VDE 0266 HXI1/HXM1

General Installation

Mecoline IS MX 1405 F

MX 20360

-40 to

12049 D 12,0 170 35 1,43

oil-resistant

BS 7655 part 2.3 RS1, BS 7655 part 2.6 SW3, EN 50264 EI109, EN 50264 EM 101-104, EN 50363 EI8, EN 50363 EM 10, EN 50363 M2/M4/EM8, IEC 60092-351 HF90, IEC 60092-359 SHF2, VDE 0207 part 23 HJ1, VDE 0207 part 24 HM1, VDE 0207 part 24 HM3, VDE 0250 HI3, VDE 0266 HXI1/HXM1

Offsh./Rolling St./Install.

Moisture crosslinkable, halogen-free insulation and sheathing compounds

Basic featuresflame-

retardanthalogen-

freelow-smoke high temp.-

resistant

flame-retardant

halogen-free

low-smoke

Basic features

Page 4: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Cable Compounds

4

Ope

rati

ng

tem

pera

ture

[°C

]

Sho

re h

ardn

ess

Tens

ile

stre

ngth

[N/m

m2]

Elo

ngat

ion

at b

reak

[%]

LOI

[%]

Den

sity

[g/

cm³]

Oil r

esis

tanc

e le

vel

Special Features Standards Application

Mecoline S RDX 1203 F

RDX 20606

-25 to

10550 D 14,0 170 34 1,48

oil-resistant

EN 50264 EM 101-104, IEC 60092-359 SHF2, NEK 606, VG 95 218 part 29 type B/C/D

Offsh./Marine/Rolling St.

Mecoline IS RDX 1207 F

RDX 2125-PV-SOLAR

-40 to

12549 D 12,0 160 34 1,50

oil-resistant

DIN/VDE DKE AK 411.2.3, TÜV 2PfG 1169/08.2007

Green Energy

Mecoline S RDX 1209 F

RDX 2245

-40 to

14545 D 13,5 175 34 1,53

oil-resistant

General Installation

Mecoline S RDX 1212 F

RDX 21606

-50

to

125

87 A 11,0 270 28 1,51oil-

resistantflex. (at lowtemperature)

IEC 60092-359 SHF2, NEK 606

Offshore

Mecoline I RDX 1213 F

-40 to

12547 D 15,5 200 30 1,39

oil-resistant

SAE J1128 GXL, SAE J1128 SXL, SAE J1128 TXL

Automotive

Mecoline S RDX 1215 F

-40 to

12583 A 13,0 200 42 1,60

oil-resistant

flex. (at lowtemperature)

EN 50264 EM 101-104, IEC 60092-359 SHF2

Offsh./Shipboard/Marine

Mecoline S RDX 1216 F

RDX 21828

-40 to

10535 D 10,5 185 34 1,53

oil-resistant

VG 95 218 part 28 type C

Marine, Aerospace, Def.

Mecoline IS RDX 1218 F

RDX 20521

-40 to

12587 A 11,0 200 45 1,60

oil-resistant

flex. (at lowtemperature)

IEEE 383, UL 1685

General Installation

Mecoline ISRDX 1221 F

RDX 2125-IN-S

-40 to

12549 D 17,0 350 32 1,41 UL 3266, UL 3271

General Installation

Mecoline I RDX 1223 F

RDX 2130-IN-S

-40 to

12548 D 14,0 400 30 1,35 UL 3266, UL 3271

General Installation

Mecoline I RDX 1229 F

RDX 22322

-50 to

12547 D 15,0 200 30 1,39

flex. at lowtemperature

HMC ES 91110-05, JASO D608 AESSXF, JASO D608 AEXF, SAE J1128 GXL, SAE J1128 SXL, SAE J1128 TXL

Automotive

Mecoline I RDX 1230 F

RDX 2264-1

-40 to

12549 D 14,0 220 32 1,49

flexible

EN 50264 EI105 & EI110

Rolling Stock

Mecoline IS RDX 1231 F

RDX 2264-3

-40 to

12585 A 12,0 180 40 1,62

oil-resistant

EN 50264 EI109 (secondary insulation only), EN 50264 EM 101-104

Rolling Stock

Radiation crosslinkable, halogen-free insulation and sheathing compounds

flame-retardant

halogen-free

low-smoke high temp.-resistant

Basic features

Page 5: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Cable Compounds

5

Ope

rati

ng

tem

pera

ture

[°C

]

Sho

re h

ardn

ess

Tens

ile

stre

ngth

[N/m

m2]

Elo

ngat

ion

at b

reak

[%]

LOI

[%]

Den

sity

[g/

cm³]

Oil r

esis

tanc

e le

vel

Special Features Standards Application

Mecoline I RDX 5210 F

RDX 31502-M01

-55 to

15051 D 20,0 350 27 1,21 ISO 6722 class C, ISO 6722 Class D, LV 112 type C & D

Automotive

Mecoline I RDX 5233

RDX 3144

-50 to

15055 D 20,0 200 23 1,05 MIL-W-81044

(primary insulation only)

Marine, Aerospace, Def.

Mecoline IS RDX 5239 F

RDX 3155-IN-F (D)

-50 to

15043 D 16,0 300 27 1,21

flex. at lowtemperature

UL 3288, UL 3289, UL 3321, UL 3398

Automotive

Mecoline IS RDX 5241 F

RDX 4144

-50

to

150

80 D 30,0 150 42 1,75oil-

resistantabrasion-resistant

MIL-W-81044(secondary insulation only)

Marine, Aerospace, Def.

Mecoline IS RDX 5242 F

RDX 4145

-50 to

15070 D 25,0 175 42 1,75

oil-resistant

abrasion-resistant

MIL-W-81044(secondary insulation only)

Marine, Aerospace, Def.

Mecoline IS RDX 5243 FRDX 4165-005-MD10

-50 to

15068 A 19,0 480 28 1,32

oil-resistant

flex. (at lowtemperature)

ISO 14572, VG 95218 part 24/25/27/282

Automotive/Marine

Mecoline IS RDX 5244 F

RDX 4225-JA-F2

-55 to

22590 A 12,0 200 45 1,90

oil-resistant

flex. (at lowtemperature)

ISO 6722 Class F

Automotive/Marine

Mecoline IS RDX 1232 F

RDX 2306-1 HT01

-40 to

12550 D 16,0 150 32 1,40

oil-resistant

abrasion-resistant

EN 50306-2, EN 50306-3

Rolling Stock

Mecoline S RDX 1247 F

RDX HSC 3000-4

-40 to

10590 A 16,0 180 38 1,45

oil-resistant

IEC 60092-359 SHF2

Offshore, Shipboard

Radiation crosslinkable, halogenated insulation and sheathing compounds

Radiation crosslinkable, halogen-free insulation and sheathing compounds

Peroxidide crosslinkableinsulation and sheathing compounds

Available on request

flame-retardant

high temp.-resistant

flame-retardant

halogen-free

low-smoke high temp.-resistant

Basic features

Basic features

Page 6: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Cable Compounds

6

Sho

re h

ardn

ess

Moo

ney

visc

osit

yM

L (1

+4

) 1

00

°C

Den

sity

[g/

cm³]

LOI

[%]

Tens

ile

stre

ngth

[N/m

m2]

Elo

ngat

ion

at b

reak

[%]

Bas

e po

lym

er

Remarks & standardsFor

tand

em

proc

ess

Coi

labl

e fo

r 2

-ste

p-pr

oces

s

Mig

rati

on

stab

ilise

d

Flam

e-re

tard

ant

PVC/PVC Migration stabilised bedding compounds for PVC insulation and PVC sheathing

FM 0422/2 85 A 27 1,96 EPR

FM 718-2 67 A 22 1,91 EPR

FM 908 BK 65 A 22 1,86 EPR For Ceander cables

FM 958 75 A 25 1,95 EPR

FM 976 70 A 27 1,88 35 EPR Flame-retardant

FM 1354/1 85 A 35 1,95 EPR

FM 1456 85 A 34 1,90 EPR

FM 1755 65 A 30 1,93 EPR Coilable / drumable

XLPE/PVC Bedding compounds for XLPE insulation and PVC sheathing

FM 0553 87 A 30 1,92 TPE-O

FM 942 75 A 25 1,80 EPR Temperature range -40°C to +60°C

XLPE/HFFR Non flame-retardant bedding compounds for XLPE insulation and HFFR sheathing

FM 989 BK 75 A 55 1,91 0,5 20 IRR

FM 1224 50 A 45 1,84 IRR

FM 1249 80 A 30 1,96 0,5 20 TPE-O

FM 1426/4 70 A 30 1,75 1,5 70 TPE-O/EPDM Good mechanical properties

FM 1724 80 A 40 1,91 NBR

XLPE/HFFR Flame-retardant bedding compounds for XLPE insulation and HFFR sheathing

FM 361 75 A 42 1,80 80 TPE-O Highly flame-retardant

FM 434/7 85 A 19 1,81 35 EPR

FM 0463 30 D 32 1,66 25 3,0 300 TPE-O Good mechanical properties

FM 972 75 A 28 1,74 50 0,5 20 EPR

FM 1239 70 A 30 1,87 55 TPE-O

FM 1248 80 A 30 1,91 45 TPE-O

FM 1604/2 38 D 30 1,59 30 4,5 250 TPE-O BS 6724, VDE 0472 part 814

FM 1639 70 A 25 1,83 51 2,2 50 TPE-O

Conductive Conductive bedding compounds

FM 264 BK 80 A 35 1,52 EPR PVC- & XLPE-Insulation

FM 303 BK 80 A 47 1,67 IRR XLPE-Insulation

Special Special bedding compounds

FM 1352 40 D 35 1,56 34 6,0 300 TPE-O BS 6724, VDE 0472 part 814

Halogen-free bedding compounds

Basic featureshalogen-

freeeconomic

Page 7: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Cable Compounds

7

Mecoline product-application matrix

Current

compound code

Previous Inhol

compound code Insu

lati

on

She

athu

ing

General

InstallationOffshore,Shipboard

GreenEnergy

Marine, Aerospace,Defence

Rolling StockRapid Transit

Railways

Automotive

Mecoline IS TP 1002 F

Mecoline S TP 1003 F

Mecoline S TP 1006 F

Mecoline S TP 1013 F

Mecoline S TP 1021 F

Mecoline IS TP 1022 F NHFR-DA 21638 NT

Mecoline S RDX 1203 F RDX 20606

Mecoline IS RDX 1207 F RDX 2125-PV-SOLAR

Mecoline S RDX 1209 F RDX 2245

Mecoline S RDX 1212 F RDX 21606

Mecoline I RDX 1213 F

Mecoline S RDX 1215 F

Mecoline S RDX 1216 F RDX 21828

Mecoline IS RDX 1218 F RDX 20521

Mecoline IS RDX 1221 F RDX 2125-IN-S

Mecoline I RDX 1223 F RDX 2130-IN-S

Mecoline I RDX 1229 F RDX 22322

Mecoline I RDX 1230 F RDX 2264-1

Mecoline IS RDX 1231 F RDX 2264-3

Mecoline IS RDX 1232 F RDX 2306-1

Mecoline I RDX 5210 F RDX 31502-M01

Mecoline IS RDX 5217 F RDX 3155-IN-F

Mecoline I RDX 5233 RDX 3144

Mecoline IS RDX 5241 F RDX 4144

Mecoline IS RDX 5242 F RDX 4145

Mecoline IS RDX 5243 F RDX 4165-005-MD10

Mecoline IS RDX 5244 F RDX 4225-JA-F2

Mecoline S RDX 1247 F RDX HSC 3000-4

Mecoline S RDX 1249 F RDX-DC 21388 (T02)

Mecoline IS MX 1403 F MX 20325

Mecoline IS MX 1404 F MX 20340

Mecoline IS MX 1405 F MX 20360

Page 8: specialty compounds · FM 0422/2 85 A 27 1,96 EPR FM 718-2 67 A 22 1,91 EPR FM 908 BK 65 A 22 1,86 EPR For Ceander cables FM 958 75 A 25 1,95 EPR FM 976 70 A 27 1,88 35 EPR Flame-retardant

Ron GoethalsDirector & Co-Owner

Inhol B.V.Zuidergracht 12NL-3763 LV SoestThe NetherlandsPhone +31 35 60 33 234Fax +31 35 60 33 [email protected]

INHE0002 - 09/2014 EUR

Information in this publication is, to the best of our knowledge, true and accurate. However, since conditions under which our products may be used are beyond our control, re-commendations are made without warranty or guarantee. Users are recommended to establish for themselves the suitability of our products in their cable construction. The above values should not be used for quality control purposes.

Jacob SteendamManaging Director