SPD Cooling : Gas pressure tests

7
Claudio Bortolin – CERN Romualdo Santoro – CERN Rosario Turrisi – INFN PD Martin Janda– CTU (Prague)

description

SPD Cooling : Gas pressure tests. Claudio Bortolin – CERN Romualdo Santoro – CERN Rosario Turrisi – INFN PD Martin Janda– CTU (Prague). DSF Pgas test: 17/10/2001. 2- bar 150W (No interlock). 1.5 bar - 100 W (interlock). DSF Pgas test: 18/10/2001. P2 Pgas test: beginning. - PowerPoint PPT Presentation

Transcript of SPD Cooling : Gas pressure tests

Page 1: SPD  Cooling :  Gas pressure tests

Claudio Bortolin – CERNRomualdo Santoro – CERNRosario Turrisi – INFN PD

Martin Janda– CTU (Prague)

Page 2: SPD  Cooling :  Gas pressure tests

1.5 bar - 100 W (interlock)2- bar 150W (No interlock)

Page 3: SPD  Cooling :  Gas pressure tests

Pgas

setpoint

Pbefore

filter

Pafter

filter

Dp Filter

Pafter

capilary

Dp capill.

Pafter

dummy

Tafter

filter

Tafter

capilary

Tafter

dummy

Pmax Flow

[bara] [bara] [bara] [bara] [bara] [bara] [bara] [°C] [°C] [°C] [W] [g/s]

1,5 3,24 2,23 1,01 1,68 0,55 1,62 19,16 13,92 11,15 85 1,5

1,65 3,26 2,27 0,99 1,78 0,49 1,72 19,64 14,43 12,8 85 1,48

1,8 3,33 2,37 0,96 1,92 0,45 1,87 20,58 16,2 14,84 100 1,46

1,9 3,31 2,38 0,96 2,04 0,31 1,98 20,19 17,86 16,21 140 1,46

2 3,32 2,39 0,93 2,11 0,28 2,06 20,36 18,69 17,43 150 1,44

2,1 3,4 2,5 0,9 2,24 0,26 2,2 20,41 20,12 19,01 150 1,41

Page 4: SPD  Cooling :  Gas pressure tests

Total HSs ON= 77 (Tmed = 29.6º C)

Pliq= 6,1 bar – Pgas=1,63 bar

Page 5: SPD  Cooling :  Gas pressure tests

Total HSs ON= 83 (Tmed = 32.8º C)

Pliq= 6,1 bar – Pgas=1,9 bar

Page 6: SPD  Cooling :  Gas pressure tests

Total HSs ON= 81 (Tmed = 31.7º C)

Pliq= 6,1 bar – Pgas=1,8 bar

Page 7: SPD  Cooling :  Gas pressure tests

Pgas=1.9 bar

Pgas=1.8 bar

ALICE Ready ALICE Beam tuning

ALICE Ready