    PV Solar Spreadsheet Enter values into shaded cells only. Cells bordered in red are calcul

    Facility Name Here

    Proposed PV System Electricity Generation and Electricity Rate

    Average Annual Electricity Consumed kWh

    Percentage of Electricity to Be Replaced by PV (0 to 100) %

    PV System Annual Supply (based on percentage above) 0 kWh/yr.

    Price (in cents) per kWh for electric service 11.00 cents/kWh

    Site Shading Characteristics Acceptable Value Range

    Annual percent of solar access available Shading Value Note: Shadi

    Shading Derate Factor 0.00 - 1.00 0.8 A number

    with 1.00 being no shading Solar Pathe

    Wiley Elect

    Solmetric S

    Component Derate Factors Acceptable Value Range

    PV module nameplate DC rating 0.80 - 1.05 0.950 Note: If th

    Inverter and Transformer 0.88 - 0.96 0.920Mismatch 0.97 - 0.995 0.980

    Diodes and connections 0.99 - 0.997 0.995

    DC wiring 0.97 - 0.99 0.980

    AC wiring 0.98 - 0.993 0.990

    Soiling 0.30 - 0.995 0.950

    System availability 0.00 - 0.995 0.980

    Shading (Entered above) 0.80

    Sun-tracking 0.95 - 1.00 1.000

    Age 0.70 - 1.00 1.000

    Overall DC to AC derate factor 0.616

    PV Module Average Daily Output Proposed 0.00

    PV Module Annual Output Proposed 0.00 kWh/yr.

    Use PVWATTS w/ data in red cells to calculate system specifications:

    http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/US/Kentucky/

    Steps:

    (1) Click closest city to your site listed on the Kentucky map

    (2) Take a guess at DC Rating and enter (use value in cell C29 above divided by 4.5 as an initial guess)

    (3) Enter DC to AC Derate Factor (cell C27)

    (4) Decide on Array Type (Fixed Tilt, Single Axis, Double Axis) and enter

    (5) For Fixed or Single Axis enter the Array Tilt from horizontal and the Array Aximuth (180.0 being due sout

    (6) Enter Price (in cents) per kWh (cell C7)

    (7) Press on Calculate

    http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/US/Kentucky/http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/US/Kentucky/
  • 7/27/2019 Solar Pv Calulator

    2/3

    (8) Does Year AC Energy (kWh) calculated match proposed (cell C30)? If not, go

    back and change DC rating and/or Array Type until you see the production you

    want.

    The DC rating entered during your final reiteration is the size of the array that will

    be needed to meet your expectations.

  • 7/27/2019 Solar Pv Calulator

    3/3

    ated values. Numbers in shaded cells are default values that can be changed.

    ing varies greatly enter shade derating based on your specific site assessment.

    f Solar Site Analysis Tools are availabe for determining shading.

    rfinder: www.solarpathfinder.com

    ronics Acme Solar Site Evaluation Tool www.we-llc.com

    unEye www.solmetric.com

    se component system factors (except shading) are not known use the given default values

    )

    http://www.solarpathfinder.com/http://www.we-llc.com/http://www.solmetric.com/http://www.solmetric.com/http://www.we-llc.com/http://www.solarpathfinder.com/