PV Solar Spreadsheet Enter values into shaded cells only. Cells bordered in red are calcul
Facility Name Here
Proposed PV System Electricity Generation and Electricity Rate
Average Annual Electricity Consumed kWh
Percentage of Electricity to Be Replaced by PV (0 to 100) %
PV System Annual Supply (based on percentage above) 0 kWh/yr.
Price (in cents) per kWh for electric service 11.00 cents/kWh
Site Shading Characteristics Acceptable Value Range
Annual percent of solar access available Shading Value Note: Shadi
Shading Derate Factor 0.00 - 1.00 0.8 A number
with 1.00 being no shading Solar Pathe
Wiley Elect
Solmetric S
Component Derate Factors Acceptable Value Range
PV module nameplate DC rating 0.80 - 1.05 0.950 Note: If th
Inverter and Transformer 0.88 - 0.96 0.920Mismatch 0.97 - 0.995 0.980
Diodes and connections 0.99 - 0.997 0.995
DC wiring 0.97 - 0.99 0.980
AC wiring 0.98 - 0.993 0.990
Soiling 0.30 - 0.995 0.950
System availability 0.00 - 0.995 0.980
Shading (Entered above) 0.80
Sun-tracking 0.95 - 1.00 1.000
Age 0.70 - 1.00 1.000
Overall DC to AC derate factor 0.616
PV Module Average Daily Output Proposed 0.00
PV Module Annual Output Proposed 0.00 kWh/yr.
Use PVWATTS w/ data in red cells to calculate system specifications:
http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/US/Kentucky/
Steps:
(1) Click closest city to your site listed on the Kentucky map
(2) Take a guess at DC Rating and enter (use value in cell C29 above divided by 4.5 as an initial guess)
(3) Enter DC to AC Derate Factor (cell C27)
(4) Decide on Array Type (Fixed Tilt, Single Axis, Double Axis) and enter
(5) For Fixed or Single Axis enter the Array Tilt from horizontal and the Array Aximuth (180.0 being due sout
(6) Enter Price (in cents) per kWh (cell C7)
(7) Press on Calculate
http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/US/Kentucky/http://rredc.nrel.gov/solar/calculators/PVWATTS/version1/US/Kentucky/ -
7/27/2019 Solar Pv Calulator
2/3
(8) Does Year AC Energy (kWh) calculated match proposed (cell C30)? If not, go
back and change DC rating and/or Array Type until you see the production you
want.
The DC rating entered during your final reiteration is the size of the array that will
be needed to meet your expectations.
-
7/27/2019 Solar Pv Calulator
3/3
ated values. Numbers in shaded cells are default values that can be changed.
ing varies greatly enter shade derating based on your specific site assessment.
f Solar Site Analysis Tools are availabe for determining shading.
rfinder: www.solarpathfinder.com
ronics Acme Solar Site Evaluation Tool www.we-llc.com
unEye www.solmetric.com
se component system factors (except shading) are not known use the given default values
)
http://www.solarpathfinder.com/http://www.we-llc.com/http://www.solmetric.com/http://www.solmetric.com/http://www.we-llc.com/http://www.solarpathfinder.com/