SkyStar SK

13
Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the SkyStar chilled water Cassette is the result of an extended technical and design development aimed at achieving the highest level in terms of performance, silent operation and control possibilities. The air diffuser has an highly attractive aesthetical appearance, very innovative, and is also able to offer the best air distribution performance thanks to in-depth computer studies and laboratory tests. The 4 smaller sizes are designed to fit into 600x600 mm false ceiling standard modules. The 3 bigger sizes have a dimension of 800x800 mm which allows the best outcome in terms of quietness and of price/performance ratio for these high capacity models. Cassette Fan Coil Unit with Asynchronous Motor SkyStar SK 1

Transcript of SkyStar SK

Page 1: SkyStar SK

Innovating and beautiful design, seven different sizes,high control flexibility, easy maintenance: the SkyStarchilled water Cassette is the result of an extended technical

and design development aimed at achieving the highest level

in terms of performance, silent operation and control possibilities.

The air diffuser has an highly attractive aesthetical appearance, very

innovative, and is also able to offer the best air distribution performance thanks

to in-depth computer studies and laboratory tests. The 4 smaller sizes

are designed to fit into 600x600 mm false ceiling standard modules.

The 3 bigger sizes have a dimension of 800x800 mmwhich allows the best outcome in terms of quietness

and of price/performance ratio for these high capacity models.

Cassette Fan Coil Unitwith Asynchronous Motor

SkyStar SK

1

Page 2: SkyStar SK

In addition to temperature and speed

standard controls,

automatic speed

selection is also available.

More than one unit can

be connected to a single control,

and the unit control panel can be installed

in a remote position that facilitatesthe maintenance operation. All the SkyStar units can be supplied in MB version. This version allows a wide range of controls, including the infra-red remote control,

which can manage one single unit or several units by using the Modbus RTU - RS 485communication protocol.

The units can be connected to the most common automatic building management systems.

emote position that facilitates

n addition to temperatu

selection is also available.

be connected to a single cont

ol panel can be installed

emote position that

n addition to temperature and speed

selection is also available.

be connected to a single control,

ol panel can be installed

emote position that facilitates

2

Page 3: SkyStar SK

Casing: made from galvanized steel with internal thermal insulation

with polyolefin (PO) foam (class M1) and external anti-condensate lining.

Control panel: made of an external metallic box

with control electronic board and easily accessible terminal board.

Air diffuser: intake grid, frame and

adjustable air distribution louvers on each side, made from ABS.

HTA versionwhite ABS, RAL 9003

HTB versionintake grid, frame and louvers

in a colour of choice

HTC versionintake grid and louversin a colour of choice,plus white ABS frame RAL 9003

MD-600 versionmetal diffuser painted in RAL 9003white colour with 600x600 dimensionto perfectly fit into the false ceilingstandard modules without overlapping parts(800x800 model is not available)

HTD versionlouvers in a colour of choice,

while the grid and frameare made from ABS, RAL 9003

Technical characteristicsof the main components:

3

Page 4: SkyStar SK

Fan assembly: the fan assembly,

which is mounted on anti-vibrating

supports, is extremely silent.

The radial fan has been designed

to optimise performance,

using wing profile blades with a shape

that reduces turbulence, increasing

efficiency and reducing noise.

The single air inlet radial fan is

connected to a 6 speedelectric motor with single phase230 V / 50 Hz supply, class B

insulation and integrated Klixon

thermal contact for motor protection.

The units are supplied

with 3 standard speeds connected and it is possible to change them on site if necessary.

Coil: made of copper tubes with bonded aluminium fins for maximum transfer contact.

The coils have 1, 2 or 3 rows for 2 pipe models

and 2+1 rows for 4 pipe models (the heating row is on the inside part of the coil).

For 4 pipe systems two versions are available:

• SK 04, SK 14, SK 24, SK 34, SK 44, SK 54, SK 64 supply an higher heating emission,

• SK 26, SK 36, SK 56, SK 66 supply an higher cooling emission.

The coil is not suitable for use in corrosive atmosphere or in environments where aluminium

may be subject to corrosion.

Condensate collection tray: high density ABS polystyrene foam condensate tray,

shaped in order to optimize the air diffusion, fire retardant rating B1 to DIN 4102.

Air synthetic washable filter, easily removable.

Condensate pump: float switch centrifugal pump with 650 mm of maximum head,

built into the unit and wired to the control panel on the outside of the casing.

Valve set: two or three way valves for ON/OFF operation, with pipe mounting kit

and thermostatic actuator.

4

Page 5: SkyStar SK

SK 02-04 / SK 12-14 / SK 22-24-26 / SK 32-34-36(Version 600 x 600)

Unit

MD-600 metal diffuser

Diffuser

28

30

22

6 3 790 350 750 15024

WEIGHTSPACKED UNIT

kg kg kg kg A B C D

WEIGHTSPACKED UNIT

WEIGHTSUNPACKED UNIT

WEIGHTSUNPACKED UNIT

PACKED UNITDIMENSIONS (mm)

SK 02 - 12 SK 04 - 14 SK 22 - 24 - 26 SK 32 - 34 - 36

MODEL

Dimensions and Weight

2 pipe units3. Flow, heating/cooling 1/2”

4. Return, heating/cooling 1/2”

4 pipe units1. Flow, heating 1/2”

2. Return, heating 1/2”

3. Flow, cooling 1/2”

4. Return, cooling 1/2”

5

Page 6: SkyStar SK

SK 42-44 / SK 52-54-56 / SK 62-64-66(Version 800 x 800)

Unit

Unit Diffuser

Diffuser

44

47

36

10 6 1050 400 1000 20039

WEIGHTSPACKED UNIT

kg kg kg kg A B C D

WEIGHTSPACKED UNIT

WEIGHTSUNPACKED UNIT

WEIGHTSUNPACKED UNIT

PACKED UNITDIMENSIONS (mm)

SK 42 SK 44 SK 52 - 54 - 56 SK 62 - 64 - 66

MODEL

Dimensions and Weight

2 pipe units3. Flow, heating/cooling 3/4”

4. Return, heating/cooling 3/4”

4 pipe units1. Flow, heating 1/2”

2. Return, heating 1/2”

3. Flow, cooling 3/4”

4. Return, cooling 3/4”

6

Page 7: SkyStar SK

3101,271,011,622,802194,54,0332425

0,110,8

4201,631,322,123,662807,06,0403132

0,150,8

6101,981,642,644,5634010,09,0494057

0,270,8

6304,213,035,128,6172410,96,7332433

0,153,0

8204,913,586,03

10,1684514,39,9403148

0,233,0

11406,164,597,7713,14106021,615,1483977

0,363,0

3101,841,352,224,193164,94,1332425

0,111,4

4202,341,752,904,914027,66,3403132

0,151,4

5202,682,043,355,684619,78,2453644

0,201,4

7105,313,465,6110,259139,47,9342542

0,184,0

9706,784,487,3413,43116614,712,4403163

0,284,0

15009,516,4810,7119,76163626,923,053441200,534,0

3202,251,572,564,833874,63,5332425

0,112,1

5003,342,393,936,965749,47,3453644

0,202,1

7104,333,185,239,2574515,111,4534468

0,322,1

7105,313,716,1310,259139,47,9342542

0,184,0

12808,456,0910,3017,26145321,818,6483995

0,424,0

182011,108,2514,0023,68190935,630,658491700,744,0

4302,942,083,436,105067,56,7413232

0,152,1

6103,882,814,638,2566712,411,2494057

0,272,1

8805,023,746,1710,6386319,717,7595090

0,452,1

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3Speed

Speed

Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CWater flowDp Cooling (E)Dp Heating (E)Sound power Lw (E)Sound pressure Lp (*)

Water contentDimensions

Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CWater flowDp Cooling (E)Dp Heating (E)Sound power Lw (E)Sound pressure Lp (*)

Water contentDimensions

m3/hkWkWkWkWl/hkPakPa

dB(A)dB(A)

WAl

mm

m3/hkWkWkWkWl/hkPakPa

dB(A)dB(A)

WAl

mm

Fan (E)

Fan (E)

575 x 575 x 275

820 x 820 x 303

MODEL

MODEL

SK 02

SK 42

SK 12

SK 52

SK 22

SK 62

SK 32

(E) = Eurovent certified performance.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.

COOLING (summer mode)

Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.

HEATING (winter mode)

Entering air temperature: +20°CEntering water temperature: +50°C

Water flow rate as for the cooling conditions

2 pipe units. The following standard rating conditions are used:

7

Page 8: SkyStar SK

1 2 3 1 2 3 1 2 3 1 2 3 1 2 3

1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3

3202,091,493594,01,981703,6332425

0,111,70,5

5003,062,245267,02,712336,0453644

0,201,70,5

7103,932,9567610,53,352889,0534468

0,321,70,5

7104,523,2577710,36,4555511,5342542

0,183,01,4

12806,935,18119222,19,9885825,3483995

0,423,01,4

18208,896,84152934,712,70109238,858491700,743,01,4

4302,361,754067,23,102678,8413232

0,151,40,7

6103,022,2951911,23,9734113,8494057

0,271,40,7

8803,812,9765517,04,9542620,5595090

0,451,40,7

7104,993,538589,05,234506,5342542

0,183,61,1

12807,845,73134820,07,7466613,0483995

0,423,61,1

182010,207,68175432,09,8084319,558491700,743,61,1

4302,721,974686,02,462125,0413232

0,151,70,5

6103,532,626079,03,062637,8494057

0,271,70,5

8804,533,4677914,03,7932611,0595090

0,451,70,5

3201,851,343184,62,432095,7332425

0,111,40,7

5002,651,984568,83,4629810,8453644

0,201,40,7

7103,342,5657413,44,4037816,6534468

0,321,40,7

7104,993,538589,05,234506,5342542

0,183,61,1

9706,334,55108914,06,425529,2403163

0,283,61,1

15008,776,49150825,08,5673615,353441200,533,61,1

3101,511,152606,0

1,961696,5332425

0,111,00,6

4201,961,5533710,02,5421910,5403132

0,151,00,6

6102,331,9040113,53,0326114,5494057

0,271,00,6

6304,142,967128,8

5,915089,8332433

0,153,01,4

8205,033,6586512,57,1961814,0403148

0,233,01,4

11406,344,69109018,99,1078321,4483977

0,363,01,4

3101,851,343184,62,432095,7332425

0,111,40,7

4202,361,714066,93,022608,5403132

0,151,40,7

5202,701,984648,83,4629810,8453644

0,201,40,7

7104,523,2577710,36,4555511,5342542

0,183,01,4

9705,664,1597415,48,1069717,4403163

0,283,01,4

15007,715,83132626,911,0094629,953441200,533,01,4

Speed

Speed

Air flowCooling total emission (E)Cooling sensible emission (E)Water flowDp Cooling (E)Heating (E)Water flowDp Heating (E)Sound power Lw (E)Sound pressure Lp (*)

Cooling water contentHeating water contentDimensions

Air flowCooling total emission (E)Cooling sensible emission (E)Water flowDp Cooling (E)Heating (E)Water flowDp Heating (E)Sound power Lw (E)Sound pressure Lp (*)

Cooling water contentHeating water contentDimensions

m3/hkWkWl/hkPakWl/hkPa

dB(A)dB(A)

WAll

mm

m3/hkWkWl/hkPakWl/hkPa

dB(A)dB(A)

WAll

mm

Fan (E)

Fan (E)

575 x 575 x 275

820 x 820 x 303

MODEL

MODEL

SK 04

SK 44

SK 14

SK 54

SK 24

SK 56

SK 26

SK 64

SK 34

SK 66

SK 36

(E) = Eurovent certified performance.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.

COOLING (summer mode)

Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.

HEATING (winter mode)

Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.

4 pipe units. The following standard rating conditions are used:

8

Page 9: SkyStar SK

The SkyStar 2 pipe models are availablewith electric heater that is controlled in place of the heating coil valve.

The electric heater is controlled in place of the hot water valve and not as integration to it.The heater is hermetically sealed and supplied inside the coil pipes

and therefore can be only factory mounted.The electric heaters of the SK 12-22-32 units are for single phase 230V supply.The electric heaters of the SK 42-52-62 units are for three phase 400V supply.

Model SK 12-E SK 22-E / SK 32-E SK 42-E / SK 52-E / SK 62-EEmission 1500 Watt 2500 Watt 3000 Watt

All the SkyStar unitscan be supplied in MB version.

This version allowsa wide range of controls,

including the infra-red remote control,which can manage

one single unit or several unitsby using the Modbus RTU - RS 485

communication protocol.

SK-MB

Unit with remote electric board

On request the Skystar cassettesare available with electric control panel

reachable from belowand with the electric board

that can be placed in a remote position.

The MCT version has been designed for all environments where false ceilingsare not featured or cannot be constructed.

The cover cabinet fits perfectly to the air intake and outlet diffuser, maintainingthe appealing design that defines the SkyStar series.

The water fittings can be turned to point upwards.The MCT series includes 7 models, with an installation height of up to 5 m,

thanks to the highly flexible adjustment of the air distribution louvers.All the technical specifications described on the previous pages remain the same,

while keeping in mind that the MCT series features one coil only(two pipe systems), there is no possibility of fresh air intake,

there is no possibility of additional electric heater.The MCT version features a special casing delivered in separate packaging;

this must only be fitted after having installed the SkyStar unitand completed the water and electrical connections.

MCT

Other available Versions

SK-E

9

Page 10: SkyStar SK

SK 42-44 / 52-54-56 / 62-64-66

SK 42-44 / 52-54-56 / 62-64-66

SK 42-44 / 52-54-56 / 62-64-66

SK 42-44 / 52-54-56 / 62-64-66

SK 02-04 / 12-14 / 22-24-26 / 32-34-36

SK 02-04 / 12-14 / 22-24-26 / 32-34-36

SK 02-04 / 12-14 / 22-24-26 / 32-34-36

SK 02-04 / 12-14 / 22-24-26 / 32-34-36

Accessories

3 way ON-OFF valveswith simpli�ed kit

Valve set, 3 ways, ON-OFF,with thermoelectric actuator.

The set includes connection pipes.

2 way ON-OFF valveswith micrometric lockshield valve

Valve set, 2 ways, ON-OFF,with thermoelectric actuator.

The set includesconnection pipes and holders.

3 way ON-OFF valveswith micrometric lockshield valve

Valve set, 3 ways, ON-OFF,with thermoelectric actuator.

The set includesconnection pipes and holders.

2 way ON-OFF valveswith simpli�ed kit

Valve set, 2 ways, ON-OFF,with thermoelectric actuator.

The set includes connection pipes.

Fresh air kit

This is used to introducefresh air into the environmentdirectly through the diffuser.

PRT

Fresh air connectionCAP

Air distribution connectionCDA

10

Page 11: SkyStar SK

IAQ accessorySkyStar Cassette can be equipped with the innovative

plate type electrostatic filter, Crystall,combining air treatment

and purifying in a single product.

The electronic filter

is patented and according to

Standard UNI 11254.

product.

to

product.

to

Dimensions

SK 0 / 1 / 2 / 3(Model 600 x 600)

SK 4 / 5 / 6(Model 800 x 800)

11

Page 12: SkyStar SK

SK version

SK-MB version

3 speed control

3 speed control with electronic thermostat and manual summer/winter switch

3 speed control with electronic thermostat and summer/winter switch

Automatic speed control with electronic thermostat and summer/winter switch

Automatic speed control with electronic thermostat, summer/winter switch and liquid crystal display

Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)

Electromechanical thermostat with summer/winter switch (only for 2 pipe units)

MO-3VCR-T

TMO-TTMO-T-AU

TMO-DI

TMO-503-SV2T2T

Wall electronic controls

Remote control to be used with electronic boards described at Page 229Free-ComFreeSabiana wireless control system

Multifunction control (to be used with SK-MB version only)PSM-DI

Wall control (to be used with SK-MB version only)

RT03 infra-red remote control supplied with separate packaging (to be used with SK-MB version only)

RT03 infra-red remote control with receiver supplied with separate packaging (to be used with SK-MB version only)

Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with SK-MB version only)

Receiver for RT03 infra-red remote control and MD-600 metal diffuser supplied with separate packaging (to be used with SK-MB version only)

T-MB

RT03

RCS-RT03

RCS

RS

Electronic controls

Sabianet (to be used with SK-MB version only)

Router for Sabianet

Relay output board for Sabianet

SabianetROUTER-S

SIOS

Sabianet management system for a network of fan coils

12

Page 13: SkyStar SK

13SK-LT-EN

-07-14

Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italy

phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576

fax +39.02.9777282 / +39.02.9772820

www.sabiana.it • [email protected]

The descriptions and illustrations provided in this publication

are not binding: Sabiana reserves the right, whilst maintaining

the essential characteristics of the types described

and illustrated, to make, at any time, without the requirement

to promptly update this piece of literature, any changes

that it considers useful for the purpose of improvement

or for any other manufacturing or commercial requirements.