Simplicity Classic greenhouses instructions
-
Upload
the-greenhouse-people -
Category
Documents
-
view
499 -
download
33
description
Transcript of Simplicity Classic greenhouses instructions
Use mm’s only! A (mm) B (mm)
6’3” X 4’3”
1918
1298
6’3” X 6’4” 1918
6’3” X 8’4” 2538
6’3” X 10’4” 3158
6’3” X 12’5” 3778
6x4
6x6
6x8
6x10
6x12
Customer Services: Unit 19, Blythe Park, Cresswell, Stoke-on-Trent, ST11 9RD, UK Tel 01782 388811, Fax 01782 388818, email: [email protected]
622mm
1021
Thank you for purchasing your new greenhouse. We recommend you familiarise yourself with the instructions and read all safety information before you commence assembly.
These instructions are divided into sections; B-base, partlists,1-sides, 2-front gable, 3-rear, 4-joining the four sides together, 5-roof, 6-vent, 7-door, 8-glazing(8a horticultural glass, 8b toughened glass, 8c polycarbonate glazing when available), 9-vent attachment, 10-door attachment, 11 anchoring down, back cover-packing list. If you need to contact us for assistance please refer to the relevant section/s.
Safety Warning
Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when assembling and glazing the building.
Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately.
Do not assemble the greenhouse in high winds.
For safety reasons and ease of assembly, we recommend that this greenhouse is assembled by a minimum of two people.
Please clear all lying snow from the greenhouse roof as it can cause the roof to buckle or collapse. Site Preparation
When selecting a site for your greenhouse, it is vital that you choose as flat and level an area as possible.
A concrete or slabbed base ( slabbed recommended) will provide the most solid foundation for your greenhouse.
IMPORTANT: Do not fix your building down until the building is fully assembled, including glazing.
Avoid placing your greenhouse under trees or in other vulnerable locations.
To minimise the risk of wind damage, try to select as sheltered a site as possible, e.g. beside a hedgerow or garden fence. Additional Considerations
Please bear in mind that assembling your greenhouse can be time consuming. You may need to spread the construction over two or more days. We recommend that you avoid leaving the building partially glazed. If you ever have to leave your greenhouse half assembled and not anchored down, weigh it down with slabs or bags of sand to stop the wind moving it.
You will find it helpful to prepare a large, clean and clear area in which to work in. A garage floor or flat lawn area is ideal.
If you have arranged for someone to install your greenhouse for you, please check that all components are included. Most parts are numbered and can be identified by a stamp or removable label. Alternatively, the components can be identified by lengths detailed in the packing list (see diagram below).
Anchoring down your greenhouse should be the final stage of construction just after glazing.
Once installed, your greenhouse requires little maintenance, but to maintain the smooth running of your door WD40 or similar can be applied to the door wheels and lower door guides.
Guarantee
Your new greenhouse is guaranteed for 10 years against faulty manufacture of the framework. This does not include glazing, moving parts, accidental damage or wind damage.
KEY SYMBOL
KEY DESCRIPTION
LOOK
THINK / CHOOSE?
THIS SECTION RELATES TO ANOTHER (e.g. 1 to 5 or 9 back to 6)
CORRECT
DO NOT FIX DOWN!
CUT
TIGHTEN
DO NOT WET!
CAN BE MIRRORED
OPTION 1: base on grass
OPTION 2: base on slabs
OPTION 3: base on concrete with drainage holes.
OPTION 4: no base on brick
Use mm’s only! A (mm) B (mm)
6’3” X 4’3”
1918
1298
6’3” X 6’4” 1918
6’3” X 8’4” 2538
6’3” X 10’4” 3158
6’3” X 12’5” 3778
6x4
6x6
6x8
6x10
6x12
Part No.
Section / Part
Size (mm)
6x 4
6x 6
6x 8
6x 10
6x 12
Page Ref
SY-BOL M6X11
M6
79
93
101
125
135
SY-NUT M6
M6
79
93
101
125
135
1025 3716 2
1026 3096 2
1027 2476 2
1028 1856 2
1029 1236 2
1030 3716 2
1031 3096 2
1032 2476 2
1033 1856 2
1034 1236 2
1006
1316
2
4
4
4
4
1015
1214
2
4
6
8
10
1000
1858
1
1001
1214
4
1002
1130
1
1003
1130
1
1004
1665
2
1005
1665
2
1006
1316
4
1007
615
2
1008
611
1
1011
1858
1
1012
1841
1
1013
1130
1
1014
1130
1
1040
153
4
Part No.
Section / Part
Size (mm)
6x 4
6x 6
6x 8
6x 10
6x 12
Page Ref
85
93
622
636
1
1
1
2
2
1016
1130
2
4
6
8
10
1035 3716 1
1036 3096 1
1037 2476 1
1038 1856 1
1039 1236 1
1046
375
-
-
-
4
5
1009
1260
1
1010
390
1
300
34
1
1021
622
1
1
1
2
2
1022
543
2
2
2
4
4
1023
607
1
1
1
2
2
330 1 1 1 2 2
711
2
2
2
4
4
587
M4
6
6
6
12
12
578
M4
6
6
6
12
12
P3 + 1044
12
2
2
2
4
4
SY-CLIP
108
132
156
178
202
SYZ- CLIP
36
44
52
58
66
SY-
FOAM
5000
9
roll
12 roll
12 roll
15 roll
18 roll
1017
619
1
1018
619
2
1019
619
1
1020
1605
2
1042 wheel
2
1043 11 2
583 19 8
1041 100 2
571 fluff
3500 1
10mm
Part No.
Section / Part
Size (mm)
6x 4
6x 6
6x 8
6x 10
6x 12
Page Ref
Part No.
Section / Part
Size (mm)
6x 4
6x 6
6x 8
6x 10
6x 12
Page Ref
Part No mm Quantity
1006 1316 2
1015 1214 2
1029 1236 2
1034 1236 2
M6 10
M6 10
4’
Part No mm Quantity
1006 1316 4
1015 1214 8
1031 3096 2
1026 3096 2
M6 28
M6 28
Part No mm Quantity
1006 1316 4
1015 1214 6
1032 2476 2
1027 2476 2
M6 24
M6 24
Part No mm Quantity
1006 1316 4
1015 1214 4
1033 1856 2
1028 1856 2
M6 20
M6 20
Part No mm Quantity
1006 1316 4
1015 1214 10
1030 3716 2
1025 3716 2
M6 32
M6 32
6’
8’
12’
1034
X 2
X 2
X 2
X 2
1029
1033
1028
1032
1027
1031
1026
1030
1025
10’ X 2
1015
1015
1006
Part No mm Quantity
1000 1858 1
1001 1214 2
1002 1130 1
1003 1130 1
1004 1665 1
1005 1665 1
1006 1316 2
1007 615 2
1008 611 1
18 18 M6
2
1000
1004 1005
1006 1001 1001
1007
1002 1003
1007
1006
1002 1003
1002/1003
1008
1008
1004/1005
INTERNAL VIEW
ALL VIEWS INTERNAL
1007
1001
1004/1005
1002/1003
1007
1006
1006
1000 1000
1001 ALL VIEWS INTERNAL
Part No mm Quantity
1001 1214 2
1004 1665 1
1005 1665 1
1006 1316 2
1011 1858 1
1012 1841 1
1013 1130 1
1014 1130 1
16 16 M6
2
1011
1004 1005
1006 1001 1001
1013 1014
1012
1006
1002/1003
1004/1005 1002 1003
INTERNAL VIEW
ALL VIEWS INTERNAL
1012
1001
1004/1005
1002/1003
1012
1006
1006 1001
1011 1011
ALL VIEWS INTERNAL
8 8 M6
4 4 M6
Packed with OPTIONAL metal base!
7mm
18mm
If you have a metal base and you live in a windy location then you should drill and fix the frame to the base using 10mm nuts and bolts. Drill centrally between two vertical glazing bars for neatness (it is not essential to drill every section). Make sure the bolt head does NOT interfere with the line of the glass. Cills should be drilled 18mm from the inside vertical face to avoid the front glass face. Do NOT anchor the structure to the ground until the end!
1
8’ Part No mm Quantity
93 636 1
1016 1130 6
1037 2476 1
18
6’ Part No mm Quantity
93 636 1
1016 1130 4
1038 1856 1
14
Part No mm Quantity
85 622 1
1016 1130 2
1039 1236 1
2
1016
1016
1016
4’
10
1
1
1
2
2
2
X 2
M4 X 4
12’ Part No mm Quantity
93 636 2
1016 1130 10
1035 3715 1
1046 375 5
38
10’ Part No mm Quantity
93 636 2
1016 1130 8
1036 3096 1
1046 375 4
32
85 / 93
85 (4’ only), 93?
1046
Part No mm Quantity
1021 622 1
1022 543 2
1023 607 1
1021
1022
600 x 545
M6 10mm X 6
X 6
M4 X 2
M4 X 2
X 1
1021
1022
600mm 545mm
1023 1023
ALL-WEATHER TRANSPARENT SILICONE NOT SUPPLLIED
Part No mm Quantity
1017 619 1
1018 619 2
1019 619 1
1020 1605 2
3.5 m
3.2 m
FLUFF
1017
1020
1018
1019
FLUFF
FLUFF
1020
X 2
X 2
X 8
X 2
INTERNAL VIEW
1020
1020 1019
1020
1017
FLUFF
E.g. E.g.
R
X
S
Z
X A
D
L
R
S S S
S S
V V
A
S S
Z
X X
Z 20
234
610
X 24 450
S
A 610 x 610
D 610 x 153
L 573 x 100
1
1
5
610
A
A
N
A
Size (mm) 4’ 6’ 8’ 10’ 12’
S 610 X 1210 9 11 13 15 17
R 610 x 1144 3 5 7 8 10
A 610 x 610 3 3 3 4 4
V 600 X 545 1 1 1 2 2
E 610 X 439 1
6 610mm
N 610 X 228 1
PACKED SEPERATELY WITH GLASS, NOT IN GREENHOUSE BOX. LONG EDGE GOES TO THE INSIDE AND TOWARDS THE SKY.
S
E
A A A
A A
Z
C A
A A A
A A
U V U V U
A A
A A A
A
Size (mm) 4’ 6’ 8’ 10’ 12’
A 610 X 610 24 30 36 42 48
U 610 X 544 4 5 7 8 10
V 600 X 545 1 1 1 2 2
B 610 X 467 1
N 610 X 228 1
D 610 x 153 1
L 573 x 100 5 D
L
C B
Z
C
A A A
A
A
N
C
A A A
Z 20
234
610
C 38 464
610
R
B
R
S S S
S S
V
A
B C
Z
Z 18
232
610
D L 573 x 100 5
A
A
N
C
Or optional capping?
610
447
Size (mm) 4’ 6’ 8’ 10’ 12’
S 610 X 1208 4 6 8 10 12
R 610 x 1142 3 5 7 8 10
A 610 x 608 3 3 3 4 4
V 600 X 545 1 1 1 2 2
N 610 X 226 1
610mm 32 40 48 56 64
765mm 4
C D
610
1883
1668
1659
1233
B
1659
1233
610 610
R
123
85, 93?
85, 93?
85, 93?
85, 93?
1009
1260
1
2
2
1009
1008
1017
1019
1009
1010
1009
1010
390
1
300
n/a
1
4
4
O7mm
No 10 x 2”
Please note you will have to drill and screw through your metal base and into your solid foundation at an angle from inside the building. On a 6’ x 8’ building you should anchor the building at 10 points using 10 x 2” rawl plugs and screws (NOT SUPPLIED).
SLABS / CONCRETE / INTERNAL VIEW
EXTERNAL VIEW
SLABS / CONCRETE / INTERNAL VIEW
EXTERNAL VIEW ON GRASS / SOIL
SAND
EXTERNAL VIEW ON GRASS / SOIL
No
m
m
4’
6’
8’
10
’
12’
85
622
1
93
636
1
1
2
2
1000
18
58
1
1
1
1
1
1001
12
14
4
4
4
4
4
1002
11
30
1
1
1
1
1
1003
11
30
1
1
1
1
1
1004
16
65
2
2
2
2
2
1005
16
65
2
2
2
2
2
1006
13
16
6
8
8
8
8
1007
61
5 2
2
2
2
2
1008
61
1 1
1
1
1
1
1009
12
60
1
1
1
1
1
1010
39
0 1
1
1
1
1
1011
18
58
1
1
1
1
1
1012
18
41
1
1
1
1
1
1013
11
30
1
1
1
1
1
1014
11
30
1
1
1
1
1
1015
12
14
2
4
6
8
10
1016
11
30
2
4
6
8
10
1017
61
9 1
1
1
1
1
1018
61
9 2
2
2
2
2
1019
61
9 1
1
1
1
1
1020
16
05
2
2
2
2
2
1021
62
2 1
1
1
2
2
1022
54
3 2
2
2
4
4
No
m
m
4’
6’
8’
10
’
12’
1023
60
7 1
1
1
2
2
1024
1
1
1
1
1
1025
37
16
2
1026
30
96
2
1027
24
76
2
1028
18
56
2
1029
12
36
2
1030
37
16
2
1031
30
96
2
1032
24
76
2
1033
18
56
2
1034
12
36
2
1035
37
16
1
1036
30
96
1
1037
24
76
1
1038
18
56
1
1039
12
36
1
1046
37
5 4
5
1
1
1
2
2
9
12
12
15
18
1 sm
alls
pac
k fo
r co
rrec
t si
ze o
f b
uild
ing
BO
X P
AC
KE
D B
Y…
……
……
……
……
……
……
……
……
……
……
……
……
……