© Siemens AG 2012 Infrastructure & Cities Sector, Mobility and Logistics Division Page 1 April 2012 Siemens Element Control Computer ECC as a Safety related System for Mainline Signalling 1. The Element Control Computer (ECC) 2. Centralised / Decentralised Solutions 3. ETCS Equipment Interfaces 4. Safety Philosophy 5. Railway Signalling Cabling/ EMC 6. Summary: Key Benefits of Electronic Interlocking

Transcript of Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April...

Page 1: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 1 April 2012

Siemens Element Control Computer ECC

as a Safety related System

for Mainline Signalling

1. The Element Control Computer (ECC)

2. Centralised / Decentralised Solutions

3. ETCS Equipment Interfaces

4. Safety Philosophy

5. Railway Signalling Cabling/ EMC

6. Summary: Key Benefits of Electronic Interlocking

Page 2: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 2 April 2012

1. The Element Control Computer (ECC), Overview, typical Interfaces

Equipment

Room

ECC

Railway Signal Cables

Signals

Others as Key

Switches, TVD

PointmachinesCTR

Element Control

Computer ECC

Page 3: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 3 April 2012

1. The Element Control Computer (ECC), History

First Version developed during 1997-2000, Pilot Project Zywiec, Poland

Worldwide Countries with operational Experience, such as Germany, Switzerland, Austria, Poland, Netherlands, Great Britain, Romania, Greece, Norway, Lithuania, China, India, Saudi- Arabia, Brazil

Worldwide more than 25000 Element Operation Modules (EOM) in Service

Used for electronic Interlockings as SIMIS-W, SIMIS-D, SIMIS-IS, SICAS-S7, SICAS- ECC

Approved as per CENELEC/ EN50129 SIL 4 by EBA (German Board for Railway Safety)

Page 4: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 4 April 2012

1.1 The Element Control Computer (ECC) used for centralised Application

Equipment

Room

UPS

EOM

EOM

EOM

EOM

ECC-

Cabinet

ECC Indoor

CabinetECC Base FrameECC Extension Frame

EO

ME

OM

EO

ME

OM

EO

M

up

to

3 C

U

…….

8/16

10

3 CPUs (2-out-of-3 Computer-Configuration)

Page 5: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 5 April 2012

1.1.4 Environmental Conditions for ECC Hardware

Climatic Test EN 60068-2-1 Cold in Operation -40°C /16h

EN 60068-2-2 Dry Heat in Operation +70°C / +85°C 16h

EN 60068-2-14 Change of Temperature in Operation

-40°C / +30°C / 3h / 5 Cycles

EN 60068-2-30 Damp Heat Cyclic in Operation

+55°C / 90-100% / 48h /2 Cycles

Mechanical Test EN 60068-2-27

EN 60068-2-64

Vibration, Shock

EMC Test EN 50121

EN 61000

See 6.2

-> In Case of exceeding Limits, the Installation of Air Conditioner is possible

Page 6: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 6 April 2012

1.1.5 The ECC Signal Operation Module (SOM6)

Safety related Function:

• to switch on/off Signal Lamp

• to monitor the Lamp Current

• to monitor the Signal Cable

(Loss of Insulation)

• up to eight Signal Lamps

connectable

• to realise electrical Insulation

between Indoor and Outdoor Area

• up to two Signals per each SOM6

max. two red aspect Lamps (remain

switched on in Case of Safety Shutdown)

Page 7: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 7 April 2012

1.1.6 The ECC Point Operation Module (POM4)

Safety related Function:

• to switch the Point Machine

• to monitor the point position

• to monitor the Point Machine Cable

(Loss of Insulation)

• to realise electrical Insulation

between Indoor and

Outdoor Area

• to monitor the running Current

Page 8: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 8 April 2012

1.1.7 The ECC DC Point Operation Module (DC POM)

Safety related Function:

• to switch the Point Machine

• to monitor the point position

• to monitor the Point Machine

Cable (Loss of Insulation)

• to realise electrical Insulation

between Indoor and

Outdoor Area

• to monitor the running Current

Page 9: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 9 April 2012

1.1.8 The ECC Universal Operation Module (UNOM2)

• universal In-/Output of Messages

and Commands

Safety related Function:

• to read in Key Switch Message,

for example

• to realise electrical Insulation

between Indoor and Outdoor Area

• to monitor the Outdoor Cable

(Loss of Insulation)

Page 10: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 10 April 2012

1.1.9 The ECC Input/Output Operation Module (INOM2)

Safety related Function:

• to read in Track Vacancy Message

• to read in Relay Message

• universal In-/Output of Messages

and Commands

In contrast to UNOM2: No electrical Insulation between Indoor and Outdoor Area

realised – Indoor Use only!

• Control of existing Relay Circuits

(Interfaces)

Page 11: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 11 April 2012

1.2 The Element Control Computer (ECC) used for decentralised Application,

1.2.1 - Big decentralised Units, ECC- Outdoor Cabinet

Equipment

Room

UPS

ECC – Outdoor - Cabinet

Ethernet30 km

Optional : IL- Bus, Profibus

Page 12: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 12 April 2012

1.2 The Element Control Computer (ECC) used for decentralised Application,

1.2.2 - Small decentralised Units, MSTT- Signals, DSTT

ETCS-

BalisesMSTT-

Signal

(EOM)

Equipment

Room

ISDN

up to 15 km

Page 13: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 13 April 2012

1.2.2.1 Small decentralised Unit, MSTT- Signal, Netherlands, HSL-Zuid

Page 14: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 14 April 2012

Interlocking Architecture:

● centralised,

● decentralised

– which one is the best Solution ?

Old Matter of Dispute:

2. Centralised / Decentralised Solutions

Page 15: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 15 April 2012

Centralised:

Germany, Austria, Netherlands, Saudi- Arabia

Decentralised:

Great Britain, Switzerland, Netherlands

2. Centralised / Decentralised Solutions

-> Historical Reasons

-> Geographical Reasons

-> Environmental Conditions

-> Countries with sparsely meshed Power Supply

Page 16: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 16 April 2012

2. Centralised / Decentralised Solutions

Power Supply Cable (3.3kV)

Tr

EOM

Tr

EOM

Tr

EOM

Tr

EOM

Main Signal Cable

Signal Tails Tails Tails Tails

200m f.e.

Dist.-

Box

Dist.-

Box

Dist.-

BoxDist.-

Box

Data Cable (Information)

Equip-

ment

Room

EOM

EOM

EOM

EOM

Equipment

Room

P

S

Tails Tails Tails Tails

6.5 km

DM

decentralised

centralised

6.5 km

6.5 km

Tr

EOM

Transformer

Element

Operating

Module

P

SPower

Supply

Page 17: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 17 April 2012

Power Supply Cable (3.3kV)

Tr

EOM

Tr

EOM

Tr

EOM

Tr

EOM

Main Signal Cable

Signal Tails Tails Tails Tails

200m f.e.

Dist.-

Box

Dist.-

Box

Dist.-

BoxDist.-

Box

Data Cable (Information)

Equip-

ment

Room

EOM

EOM

EOM

EOM

Equipment

Room

P

S

Tails Tails Tails Tails

Paid by Others <=>

Not paid by Signalling

„Everywhere a Socket“

DM

Viewpoint commercial

Supply Split (PWR <-> SIG):

6.5 km

6.5 km

2.1 Centralised / Decentralised Solutions

Page 18: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 18 April 2012

Power Supply Cable (3.3kV)

Tr

EOM

Tr

EOM

Tr

EOM

Tr

EOM

Main Signal Cable

Signal Tails Tails Tails Tails

200m f.e.

Dist.-

Box

Dist.-

Box

Dist.-

BoxDist.-

Box

Data Cable (Information)

Equip-

ment

Room

EOM

EOM

EOM

EOM

Equipment

Room

P

S

Tails Tails Tails Tails

To be considered within Safety

Case acc. EN50129

DM

Viewpoint HW - Safety Case (EN50129)

6.5 km

6.5 km

2.2 Centralised / Decentralised Solutions

Page 19: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 19 April 2012

Power Supply Cable (3.3kV)

Tr

EOM

Tr

EOM

Tr

EOM

Tr

EOM

Main Signal Cable

Signal Tails Tails Tails Tails

200m f.e.

Dist.-

Box

Dist.-

Box

Dist.-

BoxDist.-

Box

Data Cable (Information)

Equip-

ment

Room

EOM

EOM

EOM

EOM

Equipment

Room

P

S

Tails Tails Tails Tails

Viewpoint Maintainability

DM

Indoor Equipment/

Outdoor Equipment

outdoorsindoors

6.5 km

6.5 km

2.3 Centralised / Decentralised Solutions

Page 20: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 20 April 2012

2.4 Centralised / Decentralised Solutions

Power Supply Cable (3.3kV) powered by Public Utility ? – Availability? - Batteries?

Tr

EOM

Tr

EOM

Tr

EOM

Tr

EOM

Main Signal Cable

Signal Tails Tails Tails Tails

200m f.e.

Dist.-

Box

Dist.-

Box

Dist.-

BoxDist.-

Box

Data Cable (Information)

Equip-

ment

Room

EOM

EOM

EOM

EOM

Equipment

Room

U

P

S

Tails Tails Tails Tails

Viewpoint Availability of Power Supply

DM

Power Supply Equipment

including Feeder

6.5 km

6.5 km

Page 21: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 21 April 2012

Old Matter of Dispute:

Interlocking Architecture:

● centralised,

● decentralised

– which one is the best Solution ?

No general answer possible, Customer and Supplier have to

find out the solution which is the best for the relevant

application

Sometimes a combination of both is perfect !

Both, centralised & decentralised architecture is possible,

using the ECC by SIEMENS

>

>

>

2. Centralised / Decentralised Solutions

Page 22: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 22 April 2012

3. ETCS Equipment Interfaces

3. 1 LEU – S21, centralised and decentralised, L1

3. 2 MSTT- Signal, decentralised, L1, L2

Level Transition

ECC - SOM

LEUS21

Signal Cable

Signal Lamp

Balise

ISDN via 1x4x0.9 Star Quad Cable

Signal Lamp

Balise

U

C

O

M

I

Data for Lamp

Data for Balise

MSTT

Balise Telegrams can be configured independently from the Signal

Lamp Current !

ECC

Page 23: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 23 April 2012

3. ETCS Equipment Interfaces, L2

IIC/OMC

Equip.

Room

ACC

Interlocking Interface

Component / Overhead

Management

Component

Interlocking Bus (fibre optical cable)

50 km

(ECC) (ECC) (ECC) (ECC)

Equip.

RoomEquip.

Room

Equip.

Room

ACC ACC ACC

(ECC)

RBC

(ECC)

H3SZSp / Sahara - Interface

Antenna

Redundant ISDN

ECC, 3 CUs with Dummy Plates

ECC, 3 CUs with EOMs

Page 24: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 24 April 2012

4. Safety Philosophy

Page 25: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 25 April 2012

4.2 How to obtain the sufficient HW- Safety- Level (SIL2 – SIL4)

+60V-60V

U-

U+

Switch 1.1

Switch 1.2

Fuse

Current

Current

+60V-60V

U-

U+

Switch 2.1

Switch 2.2

Fuse

Current

Current

SignalSOM6

Signal Voltage

ASS 1

ASS 2

Safety related functions are

independently doubled

(HW acc. EN50129)

Safety related functions are

checked within sufficient Fault

Detection Time ←

(SW acc. EN50128)

Short Circuit Detection

Loss of Insulation

of the Signal Cable

Current Detection

Position Detection (for Points)

Detected Errors may lead to

Safety Shutdown

(ASS1, ASS2, Red Error LED)

High Availability,

selective Shutdown Concept •

Page 26: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 26 April 2012

Safety Case proves that Failure

Rate is sufficient

Fault Tree based Calculation

Current

Detector 1

Current

Detector 2Short Circuit Interrupt

AND

OR

Failure Rate Rate(LAMBDA)

Failure rate,

Failure

detection time

Failure rate,

Failure

detection time

Failure rate,

Failure

detection time

Failure rate,

Failure

detection time

Caution: the resulting

Endangering Rate depends not

only on the EOM but also on the

Outdoor Cabling!

Caution: the resulting

Endangering Rate depends not

only on the EOM but also on the

Adherence of the SAR!

4.3 Fault Tree Analysis – the Split of Safety Responsibility

Page 27: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 27 April 2012

5. Railway Signalling Cabling/ EMC

5.1 Control Distance limiting Effects, the Ohmic Resistance

SOM- Switches

closed

Maximum control distance depends on the ohmic resistance of conductors

up to 6.5km possible or even bigger

Rconductor

Rconductor

U = RI

Lamp lights with

correct brightness

The secondary voltage must be adjustable at the taps of the lamp transformer

Page 28: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 28 April 2012

10

2030

40

50

60

70

85 1

00

120

150

200

500

800

5

2

0 2 4 6 8 10-2-4-6-8-10

X [m]

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

-1

-2

-3

-4

-5

He

igh

t[m

]

1

2

5

10

20

50

100

200

500

1000

Ma

gn

eticF

ield

T]

© SIEMENS AG 2012, All rights reserved

5.2 EMC with AC Traction Power Systems (2 x 25 kV Catenary)

Magnetic Field of a 2 x 25 kV Catenary

Page 29: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 29 April 2012

C1

C2

C3

C4

C5

C6

C7

C8

5.2 Control Distance limiting Effects: The Cable‘s mutual Capacitance,

in Combination with Short Circuit to Earth and induced Voltage from Traction Power

Example of a core- stranded Railway Signal Cable with defined Mutual Capacitance

Cable Damage:

Earth Leakage

SOM- Switches

Open

induced voltageUind

UindThe Cable’s

Capacitance makes

the AC current flow

to earth

Ccable

Lamp lights up

accidentally

Unwanted

primary lamp

current

Maximum control distance depends on the cable’s mutual capacitance

up to 6.5km possible or even bigger

Page 30: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 30 April 2012

5.3 EMC with AC Traction Power Systems (Catenary)

Dimensioning of Induction Protecton for Railway Signalling Cables by

Sitras Sidytrac :

Short term induced Voltage as a Consequence of Catenary Breakdown

Page 31: Siemens Element Control Computer ECC as a Safety related ... · © Siemens AG 2012 Page 6 April 2012 Infrastructure & Cities Sector, Mobility and Logistics Division 1.1.5 The ECC

© Siemens AG 2012

Infrastructure & Cities Sector, Mobility and Logistics Division Page 31 April 2012

6. Summary: Key Benefits of Electronic Interlocking

Economy

- A minimum of space required

- Fast and easy testing with approved functional modules

- Pre-assembled Implementation in containers possible

Technology

- Precondition for forward-looking Train Control System as ETCS

Availability

- Highly reliable hardware design

- Very high availability with redundant hardware

Maintenance

- Reduced maintenance due to highly reliable hardware

- Effective maintenance due to diagnostic and maintenance systems for on-line

and remote diagnosis

Safety

- Conformance to the CENELEC safety requirements

- EN50128/EN50129