SHMS Spectrometer Update Hall C 2008 Users Meeting Paul Brindza January 18, 2008.
-
Upload
terence-greene -
Category
Documents
-
view
216 -
download
0
Transcript of SHMS Spectrometer Update Hall C 2008 Users Meeting Paul Brindza January 18, 2008.
SHMS Spectrometer UpdateHall C 2008 Users Meeting
Paul Brindza
January 18, 2008
SHMS Design Parameters Parameter 2006 design (@ 7 GeV/c)
Range of Central Momentum
2 to 11 GeV/c for all angles
Momentum Acceptance -10% to 22%
Momentum Resolution 0.03-0.08%
Scattering Angle Range 5.5 to 40 degrees
Solid Angle Acceptance > 4.5 msr for all angles
Horizontal Angle Resolution
0.5-1.2 mrad
Vertical Angle Resolution 0.3-1.1 mrad
Vertex Length Resolution 0.1-0.3 cm
SHMS 2008
HB a la MSU/NSCL 2008
MSU design has warm iron
Meets SHMS spatial requirements
Features a helium cooled coil and self supporting cryostat
Trial Coil winding in 2008
Q1 2008
• Trial wind R&D resulted in higher turns density
• 70 -> 92 turns/coil
• Q1 2008 is shorter- same length as the HMS Q1
• (96 in. vs 107 in.)
Q23 2008
• Force collar Aluminum• 6cm -> 11 cm• Coil “Keys” stainless• Yoke ID 69->73 cm• Length reduced by 12 cm• Performance & size OK
Dipole 2008
• Force collar 10 ->18 cm• Yoke ID 69->79 cm• Collar is Aluminum• Coil “Keys” are Stainless• Magnet OD is the same
SHMS Support Structure and Shield HouseRecent work by ALION-JJMA Dec 2007
• Design updated to current SHMS design• “slider” removed-all magnets now fixed• HB magnet inserted• Current design for magnets and detectors • Current angular range (5.5 to 40 degrees)• Current angle SHMS-HMS (18 degrees)• Preliminary Shield House design with side
access- shielding simulation underway.
Q1 Trial winding- 2007 results
• JLAB contracted with Scientific Magnetics to develop Q1 coil tooling and wind coils
• Phase 1 is complete and produced one full size trial coil that passed all tests
• Phase 2 is about to start and will produce 2 full size Q1 coils
• Phase 1 demonstrated a higher turns density(92 vs 70) resulting in a shorter Q1
Q1 Trial WindingB stage tape application (left) Coil end turn former (right)
Q1 Winding Tooling
Q1 Full Size Coil Sept 2007
Coil Pack Dimensions
10.52
10.54
10.56
10.58
10.60
10.62
10.64
10.66
10.68
10.70
10.72
-100 -50 0 50 100
Z-Position (cm)
Co
il P
ack
Th
ickn
ess
(cm
)
Straight A
Straight B
Uniformity of Q1 Coil straight section height
J-Lab Test Coil 2 - Shorted Turns Test
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1 11 21 31 41 51 61 71 81
Turn
Vo
ltag
e (V
)
Verification of Insulation Integrity
SHMS Conductor Testing CompleteShort Sample Test Data
0
2000
4000
6000
8000
10000
12000
0 5 10 15 20 25 30
Test number
Cri
tica
l cu
rren
t
Series1
Series2
Series3
6 Tesla Data
7 Tesla Data
8 Tesla Data
Q23 and Dipole Force Collar Analysis
• Parallel analysis projects at JLAB, FNAL, ACCEL and NOVATECH
• Consensus results( ie typical data) suggest
Use thicker Aluminum Force collar
Use Stainless “keys” instead of Titanium
Preload achieved after cool down
Coils stay clamped at Max Field• Need to measure copper stabilizer properties at
4.2 Kelvin- R&D at FNAL in 2008
NovaTechJLAB
ACCEL FERMI
Dipole and Q23 FEA results
SHMS Conclusions
• Improvements in magnet designs have increased the available free space along SHMS optical axis
• R&D program: HB Design, Q1 Trial Wind and Force Collar Analysis resulted in improvements in the SHMS design and Value Engineering
• Support Structure design work has advanced credibility and confidence in SHMS Design.
• Believe it or not we will start SC magnet procurement this summer!!!!!