SHIPBOARD CABLE
No. EMS 00151No. OSH 00971
No. QCS 00152
PT. KABELINDO MURNI Tbk
WIRE AND CABLE MANUFACTURER
-
Introduction of company
The Companys history was marked by the founding of PT. Kabel Indonesia
(Kabelindo) in 1972, a foreign invested Company at the time and one of the first cable
manufacturers in Indonesia. In 1979, the Companys ownership was transferred to
Indonesians and names was changed to PT. Kabelindo Murni.
The quality assurance of the products is the main issue that the Company
emphasizes. The electrical cables produced by the Company has passed the Indonesian
National Standard (SNI) and National Power Company Standard (SPLN). The Company
completes several international standards such us : Standard International Electrotechnical
(IEC), Australian Standard (AS), British Standard (BS), Japanese Industrial Standard (JIS) and
Insulated Cable Engineers Association / National Electrical Manufacturers Association (ICEA/
NEMA)
To Support the Companys commitment to quality, the Company has the ISO 9001:2008
OHSAS 18001 : 2007 ISO 14001 : 2004 certificate.
Shipboard Cable
Application: This product is suitable for use in power, control, instrumentation and communication system of ships and water buildings.
Operating Temperature: Max permissible continuous operating temperature of conductor
850C for EPR insulated shipboard cable;
900C for XLPE insulated shipboard cable.
700C for PVC insulated shipboard cable.
Bending Radius: Permissible bending radius
6D for metal braided armoured cable;
6D for unarmoured cable, D > 25 mm;
4D for unarmoured cable, D 25 mm;
D = Actual outer diameter of cable (mm)
Standard: IEC 60092-series, IEC 60332, IEC 60331 or other standards required by customers.
Packing: Steel/wooden reel, wooden reel or steel reel.
-
Certificate
SHIPBOARD CABLE
-
SHIPBOARD CABLESHIPBOARD CABLE CONSTRUCTION
Cable Designation
IEC Nomenclature Type of cables JIS Nomenclature
CEV90DA/NASingle core, EP rubber insulated, PVC sheathed, and steel wire
braided cable(FA-)SPYC
CEV92DA/NASingle core, EP rubber insulated, PVC sheathed, and steel wire
braided cable with protective covering(FA-)SPYCY
CEVSA/NA (2, 3, 4, 5, 6 Core) Double core, EP rubber insulated, and PVC sheathed cable (FA-)DPY
Three core, EP rubber insulated, and PVC sheathed cable (FA-)TPY
Four core, EP rubber insulated, and PVC sheathed cable (FA-)FPY
5core, EP rubber insulated, and PVC sheathed cable (FA-)5PY
6core, EP rubber insulated, and PVC sheathed cable (FA-)6PY
Multi core, EP rubber insulated, and PVC sheathed cable (FA-)MPY
CEV90SA/NA (2, 3, 4, 5, 6 Core)Double core, EP rubber insulated, PVC sheathed and steel wire
braided cable(FA-)DPYC
Three core, EP rubber insulated, PVC sheathed and steel wire
braided cable(FA-)TPYC
Four core, EP rubber insulated, PVC sheathed and steel wire
braided cable(FA-)FPYC
5core, EP rubber insulated, PVC sheathed and steel wire braided
cable(FA-)5PYC
6core, EP rubber insulated, PVC sheathed and steel wire braided
cable(FA-)6PYC
Multi core, EP rubber insulated, PVC sheathed and steel wire
braided cable(FA-)MPYC
CEV92SA/NA (2, 3, 4, 5, 6 Core)Double core, EP rubber insulated, PVC sheathed, and steel wire
braided cable with protective covering(FA-)DPYCY
Three core, EP rubber insulated, PVC sheathed, and steel wire
braided cable with protective covering(FA-)TPYCY
Four core, EP rubber insulated, PVC sheathed, steel wire braided
and protective covering cable(FA-)FPYCY
5core, EP rubber insulated, PVC sheathed, and steel wire braided
cable with protective covering(FA-)5PYCY
6core, EP rubber insulated, PVC sheathed, and steel wire braided
cable with protective covering(FA-)6PYCY
Multi core, EP rubber insulated, PVC sheathed and steel wire
braided cable with protective covering(FA-)MPYCY
-
SHIPBOARD CABLESHIPBOARD CABLE CONSTRUCTION
Cable Designation
IEC Type of cables JIS
CEVP80DA/NASingle core, EP rubber insulated, PVC sheathed and steel wire or
copper alloy braided cable with collective screen(FA-)SPYCS, (FA-)SPYCBS
CEVP82DA/NASingle core, EP rubber insulated, PVC sheathed, steel wire or copper
alloy braided and protective covering cable with collective screen(FA-)SPYCYS, (FA-)SPYCBYS
Double core, EP rubber insulated, PVC sheathed and steel wire
braided cable with common shield(FA-)DPYCS
Three core, EP rubber insulated, PVC sheathed and steel wire
braided cable with common shield(FA-)TPYCS
Four core, EP rubber insulated, PVC sheathed and steel wire braided
cable with collective screen(FA-)FPYCS
Double core, EP rubber insulated, PVC sheathed, steel wire braided
and protective covered cable with common shield(FA-)DPYCYS
Three core, EP rubber insulated, PVC sheathed, steel wire braided
and protective covered cable with common shield(FA-)TPYCYS
Four core, EP rubber insulated, PVC sheathed, steel wire braided and
protective covering cable with collective screen(FA-)FPYCYS
Double core, EP rubber insulated, and PCP sheathed cable (FA-)DPNP
Three core, EP rubber insulated, and PCP sheathed cable (FA-)TPNP
Four core, EP rubber insulated, and PCP sheathed cable (FA-)FPNP
CJ/NA XLPE insulated switch board cable (FA-)SCP
CV/NA PVC insulated switch board cable (FA-)SYP
CHEVP90SA/NAMulti core, EP rubber insulated, PVC sheathed and steel wire braided
cable with common shield(FA-)MPYCS
CHEVP92SA/NAMulti core, EP rubber insulated, PVC sheathed, steel wire braided and
protective covered cable with common shield(FA-)MPYCYS
CHEVP390SA/NAMulti core, EP rubber insulated, PVC sheathed and steel wire braided
cable with individual shield(FA-)MPYC-S
CHEVP392SA/NAMulti core, EP rubber insulated, PVC sheathed, steel wire braided and
protective covered cable with individual shield(FA-)MPYCY-S
CHEVP/NA (2, 3, 4, 5, 6 Core)
CHEVP90/NA (2, 3, 4, 5, 6 Core)
CEFSA/NA (2, 3, 4, 5, 6 Core)
Note : For another insulation type, inner sheath and sheathing type by customer request
-
SHIPBOARD CABLESHIPBOARD CABLE CONSTRUCTION
Cable Nomenclature
IEC Nomenclature
JIS Nomenclature
Main use and no. of core Insulation type Sheath Armouring Covering Otherwise
S
D
T
F
5
6
M
TT
P
FA-
FRT-
FRT(A)-
S
Single core
Double core
Three core
Four core
5 core
6 core
Multi core
Portable and flexible
Telephone and instrument
Flame retardant (IEC 60332-3A)
Fire resistant (IEC 60331)
Flame retardant and fire resistant
Switch board cable
P
Y
C
Y
N
C
CB
Y S
-S
E
EPR
PVC
FR-XLPE
PVC
PCP
Steel wire braid
Copper alloy wire braid
PVC Common shield
Individual core and pair shield
Earth wire
Code Explanation
Code for cable series C Shipboard power cable
CK Shipboard control cable
CH Shipboard communication cable and signal cable
Code for insulation E EPR
J XLPE
V PVC
Code for sheath F CR(SE1)
H CSM (SH)
PF LOSH Non-cross-Linked PO sheath (SHF1)
PJ LOSH Cross-Linked PO sheath (SHF2)
V PVC sheath
Code for armour and outer sheath 0 No outer sheath
2 PVC outer sheath
5 Cross- Linked PO oter sheath
6 Non-cross-linked PO outer sheath
8 Tinned copper wire braided
9 Galvanized steel wire braided
Code for other contruction P Wire or twisted pair with individual
R Flexible construction for conductor
Code for flammability DA Single cable flame retardant (IEC60332-1-2)
DC Single flame retardance, low-smoke, halogen free, low toxicity
NC/NSC Fire resistant, low-smoke, halogen free, low toxicity
Bunched cable flame retardant ( IEC60332-3-22)
SA Bunched flame retardance, low-smoke, halogen and toxicity
SC Bunched cable flame retardance, low-smoke, halogenfree, low toxicity
NA/NSA Fire resistant, low- smoke, halogen free and low toxicity
-
SHIPBOARD CABLESHIPBOARD CABLE CONSTRUCTION
Product Size Range
3 Core : 1 up to 185 mm
Single Core : 1 up to 300 mm
2 Core : 1 up to 185 mm
4 Core : 1 up to 185 mm
Multi Core (5 core ) : 1 2.5 mm
60092-350 : Shipboard power cables General construction and test requirements
60092-351 : Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables
60092-352 : Choice and installation of cables for low-voltage power systems
60092-353 : Single and multicore non-radial field power cables with extruded solid insulation for rated voltage 1 kV and 3 kV
60092-354 : Single and three-core power cables with extruded solid insulation for rated voltage 6 kV (Um = 7.2 kV) up to 30 kV (Um = 36 kV)
60092-359 : Sheathing materials for shipboard power and telecommunication cables
60092-376 : Cables for control and instrumentation circuits 150/250 V (300 V)
Reference IEC Standard
-
SHIPBOARD CABLE
PT KABELINDO MURNI TbkJln Rawagirang No. 2 Kawasan Industri Pulogadung, Jakarta 13930INDONESIA
Telp : +62 21 460 9065 ; +62 21 460 9550Fax : +62 21 460 9064 ; +62 21 4604271Email : [email protected]
Bare Wire (Overhead Conductor)
All Aluminium Stranded Conductor (AAC)
Aluminium Conductor Steel Reinforced (ACSR)
All Aluminium Alloy Conductor (AAAC)
Thermal Aluminium Conductor Steel Reinforced (T-ACSR)
Aluminium Conductor Aluminium Clad Steel Reinforced (ACSR/AS)
Aluminium Conductor Composite Core (ACCC/TW)
Power Cable
PVC Insulated Power Cable
Low and Medium Voltage XLPE Insulated Power Cable Up to 36 kV
Overhead Cable
All Aluminium Conductor XLPE Insulated Twist Cable (NFA2X)
All Aluminium Conductor Aluminium Alloy Messenger XLPE Insulated (NFA2X-T)
All Aluminium Alloy Conductor XLPE sheath (AAAC-S)
All Aluminium Conductor XLPE Insulated Aluminium Alloy Messenger (NFA2XSY-T)
Shipboard Cable
Building Wire
Control And Instrument Cable
PVC Insulated
XLPE Insulated
Telecommunication Cable
Telephone Cable
RF Cable and Accessories
Bare Conductor Low Voltage Cable Medium Voltage CableInstrument Cable Control Cable Shipboard Cable Fire Resistant Cable
Flame Retardant Cable Telephone Cable RF Feeder Cable And Accessories
Range Product Supply
flyer sb rev 01.vsdPage-1Page-2Page-3Page-4Page-5Page-6Page-7Page-8