UNLESS NOTED OTHERWISE
FACE OF FOAMF.O.F.
FACE OF STUD
FIELD VERIFYFOOTING
GALVANIZED GALVANIZED IRONGYPSUM BOARD
HEADERHEIGHT
FACE OF MASONRY
HT.HDR.
F.O.S.
F.V.FTG.
GALV.G.I.GYP. BD.
F.O.M.
W/O
W.P.W.I.
WD.W/
V.T.R.VAR.
UNFIN.U.N.O.
WITHOUT
WEATHERPROOFWROUGHT IRON
VENT THRU ROOF
UNFINISHED
WOODWITH
VARIES
MATERIALMAT.MANUFACTUREDMANUF.A.F.F. ABOVE FINISH FLOOR
PENNYd
ELEVATIONEXHAUST FAN
EXTERIOREXPANSION JOINTEXISTING
DISHWASHERDOWNSPOUTDOWN
DRAWINGS
DIMENSION
FINISHFINISH FLOORFLOOR DRAIN
FLOOR
DOUBLE
ELEV.
EXT.EXP. JT.EXIST'G
FIN.F.F.F.D.
FLR.
EA.E.F.
D.W.DS.DN.
DWGS.
DIM.DBL.
EACH
CONTROL JOINT
CEILINGCENTER LINE
CLEAR
COLUMNCONCRETE MASONRY UNIT
CONCRETECONTINUOUS
CASEMENTCARPET
BOTTOM OF FOOTING
BLOCKINGBOARD
ANGLE
CLCLG.CLR.
COL.CMU.
CONC.CONT.
CSMT.CPT.
C.J.
B.O.F.
BLK'G.BM.
BD.
BEAM
REQUIREDREQ'D.
TH.TEMP.
T.O.P.T.O.M.T.O.C.
T.O.W.TYP.
T.O.S.
T.
SIM.S.S.
S.C.SHTH'G
STRUCT.STL.
R.O.
TEMPERED
TOP OF PARAPETTOP OF MASONRYTOP OF CURB
TOP OF WALLTOP OF SLAB
THICK
TREAD
TYPICAL
STAINLESS STEEL
SOLID CORESHEATHING
STRUCTURAL
ROUGH OPENING
SIMILAR
STEEL
REFR.
PR.
P. LAM.PLYWD.
P.T.
R
PL
O.C.O.H.
N.T.S.N.I.C.
MTL.
O/
REFRIGERATOR
PLASTIC LAMINATEPLYWOOD
PRESSURE TREATED
RISER
PAIR
PLATE
ON CENTEROVERHEAD
NOT TO SCALENOT IN CONTRACT
OVER
METAL
ABBREVIATION LEGEND
ANCHOR BOLTAIR CONDITIONING
ABOVEA.B.ABV.
A/C INT.
INSULATIONINTERIOR
ROOF SLOPE DESIGNATION
SHEET #
SECTION DESIGNATION
SYMBOL LEGEND
A4.1A
SILL PLATE LOCATION ABOVE
ROOM CEILING HEIGHT
ROOM DIMENSIONS
WINDOW / DOOR ABBREVIATION KEY:SH:FIX: FIXED FRAME
SINGLE HUNG
HORIZONTAL SLIDERSLDR:SLIDING DOORSGD:TEMPERED GLAZING REQUIREDTEMP:
PCKT:BP:
POCKET DOORBI-PASS SLIDING DOOR
BF: BI-FOLD DOOR
9' CLG. HT.
10'1" X 11'2"
ROOM NAME
10:12
PROJECT DIRECTORY
STRUCTURAL:
ARCHITECTURAL:
BUILDER: Company:Address:Email:Phone:
J.P. DESIGN - Forever Homeswww.jpdesignhomes.comPlan Sales:www.gowlerhomes.com
Company:Address:Email:Phone:
BUILDING TYPE: V-B
BUILDING OCCUPANCY: R-3
BUILDING HEIGHT ABOVE TOP OF FOUNDATION: 30'-11 1/4"
MAIN LEVEL TOTAL 2524 S.F.
UPPER LEVEL TOTAL 2361 S.F.
FRONT PORCH 496 S.F
REAR PATIO 306 S.F.
GARAGE TOTAL 1424 S.F.
ARCHITECTURAL
ELECTRICALSHEET NO: DESCRIPTION
E1.1 MAIN LEVEL ELECTRICAL PLAN
E1.2 UPPER LEVEL ELECTRICAL PLAN
SHEET NO: DESCRIPTION
A1.0 COVER SHEET / PROJECT INFORMATION
A1.1 MAIN LEVEL FLOOR PLAN
A1.2 UPPER LEVEL FLOOR PLAN
A2.1 FRONT AND REAR ELEVATIONS
A2.2 LEFT AND RIGHT ELEVATIONS
A3.1 ROOF PLAN
A4.1 BUILDING SECTION AND DETAILS
SHEET INDEX
STRUCTURALSHEET NO: DESCRIPTION
S1.1 FOUNDATION PLANS BY OTHERS
S1.2 FLOOR FRAMING SHEETS BY OTHERS
S1.3 ROOF FRAMING SHEETS BY OTHERS
SECTION IDENTIFICATIONINSUL.
PROJECT DATA
GENERAL CONSTRUCTION NOTES
1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALLOBTAIN ALL PERMITS REQUIRED BY REGULATORY AUTHORITIES.
2. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, LAWS, ANDORDINANCES APPLICABLE TO THIS PROJECT.
3. THE CONTRACTOR SHALL VERIFY ALL SETBACKS, EASEMENTS,UTILITIES, AND MEASUREMENTS PRIOR TO THE START OFCONSTRUCTION.
4. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, THE EXACTLOCATION OF UTILITY TAPS, THE CONNECTION OF UTILITY LINES FROMTHE BUILDINGTO SERVICE LINES, AND ALL FEES SHALL BE THERESPONSIBILITY OF THE CONTRACTOR.
5. ALL WORK DONE OUTSIDE THE PROPERTY LINES SHALL BE DONE INACCORDANCE WITH THE REGULATORY AUTHORITIES.
6. ALL MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEERINGREQUIRED FOR THIS PROJECT IS BY OTHERS.
7. FOUNDATION DESIGN TO BE COMPLETED UPON SITE INSPECTION OFSOILS BY A STATE REGISTERED ENGINEER. DESIGN TO BE ON HANDAT TIME OF FIRST INSPECTION. ALL STRUCTURAL ENGINEERINGDESIGN SHALL BE COORDINATED BY A PROFESSIONAL ENGINEER
8. CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROMSITE AS REQUIRED.
9. ALL INTERIOR FINISHES SUCH AS CARPET, PAINT, TILE, HARDWOOD,ETC. SHALL BE SELECTED BY THE CONTRACTOR WITH THECONTRACTOR COORDINATING ALL SELECTIONS.
10. ALL CABINETS, BUILT-INS, SHELVING, ETC. SHALL BE COORDINATEDBY THE CONTRACTOR.
11. ALL FIRE PROTECTION, LIGHTING PROTECTION, SECURITY SYSTEMS,AND HOME MANAGEMENT SYSTEMS AND ENGINEERING REQUREDFOR THESE SYSTEMS IS BY THE CONTRACTOR AND SHALL BECOORDINATED BY THE CONTRACTOR.
12. ALL DOORS, INTERIOR AND EXTERIOR, AND HARDWARE SHALL BE ASSELECTED BY AND COORDINATED BY THE CONTRACTOR.
13. BUILDER TO COORDINATE INSULATION OF RESIDENCE PER LOCALCODES, TYPICAL.
14. IT IS IMPERATIVE THAT THE CONTRACTOR OBSERVE MANUFACTURERSINSTRUCTIONS AND PROCEDURES IN INSTALLING ALL MATERIAL ANDEQUIPMENT. ALL INSTRUCTIONS AND WARRANTIES OF ALLMATERIALS AND EQUIPTMENT TO BE DELIVERED TO THE BUILDERPRIOR TO CONSTRUCTION.
15. IT IS RECOGNIZED THAT THE CONTRACT DOCUMENTS AREDIAGRAMMATIC IN SHOWING CERTAIN PHYSICAL RELATIONSHIPS OFTHE VARIOUS ELEMENTS AND SYSTEMS AND THEIR INTERFACINGWITH OTHER ELEMENTS AND SYSTEMS. ESTABLISHMENTS ANDCOORDINATION OF THESE RELATIONSHIP IS THE EXCLUSIVERESPONSIBILITY OF THE CONTRACTOR. DO NOT SCALE THEDRAWINGS. LAYOUT AND ARRANGE ALL ELEMENTS TO CARRY THEHARMONY OF THE DESIGN THROUGHOUT THE WORK.
16. DESIGNER NOT RESPONSIBLE FOR ANY CHANGES MADE TO THIS PLANDURING CONSTRUCTION BY OWNER, CONTRACTOR ORSUBCONTRACTORS.
17. THE BUILDER IS RESPONSIBLE FOR ALL CONSTRUCTION METHODS,TYPICAL.
__
-_
_-2
01
9
Co
nstru
ctio
n
Co
mp
an
y:
Bu
ild
er:
Em
ail:
Ph
on
e:
1/4
" =
1
'-0
"
Copyright
c
ww
w.jp
de
sig
nh
om
es.co
m
JP
D
esig
n, L
LC
Site
A
dd
re