Severe Duty – TEFC Motors - IBT Industrial Solutions · PDF fileefficiency while larger...

2
Severe Duty – TEFC Motors RGZEESD NEMA PREMIUM | efficient NEMA Premium Efficiency TEFC motors are the motors that can pay for themselves through energy savings. According to NEMA, electric motors consume 10 to 25 times their purchase price in electricity each year of operation. It is easy to see that increases in motor efficiency can significantly reduce operating costs. These motors are ideal for severe operating atmospheres in applications such as: chemical processing, mining, foundry, pulp and paper, waste management and petro/chemical. Performance Specifications 1 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800 or 1200 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above; 575 volt available Meets or exceeds NEMA Premium™ Efficiencies Class F insulation, Class B temperature rise NEMA Design B, Continuous Duty 0.08 IPS vibration 143T through S449 frame Features for Long Life Frame & End Shields – Cast iron construction for exceptional structural integrity with condensation T-drains. Lifting eyebolts are included for all frames. Rotor – A unique offset rotor bar design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high-strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings – Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation – Proprietary inverter-rated Class F non-hygroscopic insulation system with NEMA Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2003, Par.t 31 to make all motors suitable for operation with variable frequency drives. Cooling – A bi-directional, non-sparking fan is locked and keyed to the shaft. Its low-inertia design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings – Regreasable, oversized single shielded with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. All motors are equipped with drive end and opposite drive end shaft V-ring slingers for added bearing protection. Provisions for Inpro/Seal® bearing isolators are standard on both ends. Lubrication – A specially formulated, high temperature tested, polyurea based grease is used to provide more than four times the lubrication life of other polyurea greases. Oversized Conduit Box – Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. Includes a ground lug and non-wicking, clearly and permanently marked leads. Corrosion Resistance – Cast iron construction, zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. Modifiable – All Siemens motors are available with a wide variety of modifications to meet your specific motor needs.

Transcript of Severe Duty – TEFC Motors - IBT Industrial Solutions · PDF fileefficiency while larger...

Page 1: Severe Duty – TEFC Motors - IBT Industrial Solutions · PDF fileefficiency while larger bars and end rings reduce resistance for ... Stator/Windings ... an extra margin of thermal

Severe Duty – TEFC MotorsRGZEESD

NEMA PREMIUM™ | efficient

NEMA Premium™ Efficiency TEFC motors are the motors that canpay for themselves through energy savings. According toNEMA, electric motors consume 10 to 25 times their purchaseprice in electricity each year of operation. It is easy to see thatincreases in motor efficiency can significantly reduce operatingcosts. These motors are ideal for severe operating atmospheresin applications such as: chemical processing, mining, foundry,pulp and paper, waste management and petro/chemical.

Performance Specifications

■ 1 to 400 HP■ 1.15 service factor, 40ºC ambient■ 3600, 1800 or 1200 RPM■ 3 phase, 60 Hz; 230/460 volt operation under 25 HP,

460 volt 25 HP and above; 575 volt available■ Meets or exceeds NEMA Premium™ Efficiencies■ Class F insulation, Class B temperature rise■ NEMA Design B, Continuous Duty■ 0.08 IPS vibration■ 143T through S449 frame

Features for Long Life

Frame & End Shields – Cast iron construction for exceptionalstructural integrity with condensation T-drains. Lifting eyeboltsare included for all frames.

Rotor – A unique offset rotor bar design provides improvedefficiency while larger bars and end rings reduce resistance forlower rotor losses. Each die cast aluminum rotor assembly isdynamically balanced for extended bearing life, and includes ahigh-strength carbon steel (C1045) shaft for maximum rotorperformance.

Stator/Windings – Manufactured with premium electrical gradesteel laminations and copper electrical magnet wire to lower lossesfor improved efficiencies. A unique stator core design lowers fluxdensity while increasing cooling capacity. Large conductor crosssection reduces resistance, also lowering stator losses.

Insulation – Proprietary inverter-rated Class F non-hygroscopicinsulation system with NEMA Class B temperature rise, providesan extra margin of thermal life. Varnish system applicationensures maximum wire penetration to provide protection frommoisture, corrosion and electrical shock. This insulation system

meets or exceeds NEMA MG1-2003, Par.t 31 to make all motorssuitable for operation with variable frequency drives.

Cooling – A bi-directional, non-sparking fan is locked andkeyed to the shaft. Its low-inertia design reduces windagelosses, improves airflow, reduces noise and providesdependable cooling. Cast iron fan covers are provided on allframe sizes.

Bearings – Regreasable, oversized single shielded with castiron inner caps. Alemite grease fittings on the inlets and pipeplugs on the relief ports for ease of routine maintenance. Allmotors are equipped with drive end and opposite drive endshaft V-ring slingers for added bearing protection. Provisionsfor Inpro/Seal® bearing isolators are standard on both ends.

Lubrication – A specially formulated, high temperature tested,polyurea based grease is used to provide more than four timesthe lubrication life of other polyurea greases.

Oversized Conduit Box – Cast iron construction that is largerthan industry standards, diagonally-split, neoprene gasketedand rotatable in 90º increments for quick and easy connections.Includes a ground lug and non-wicking, clearly andpermanently marked leads.

Corrosion Resistance – Cast iron construction, zinc-platedhardware, epoxy enamel paint and aluminum nameplate resistrust and corrosion.

Modifiable – All Siemens motors are available with a widevariety of modifications to meet your specific motor needs.

Page 2: Severe Duty – TEFC Motors - IBT Industrial Solutions · PDF fileefficiency while larger bars and end rings reduce resistance for ... Stator/Windings ... an extra margin of thermal

Performance Specifications460 Volts, NEMA Design B, 40ºC Ambient

HP111

1.51.51.5222333555

7.57.57.5101010151515202020252525303030404040505050606060757575

100100100125125125150150150200200200250250250300300300350350400400

SynchRPM3600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180012003600180036001800

F.L.RPM3495176011603495175511753495175511753505177011803485176511753535177011803520177011803530177011803525177011803525177511853525177511853535178011853535178011853565178011853565178011853570178011853575178511853575178511903575178511903570178511903575178511853570178535701785

Frame143T143T145T143T145T182T145T145T184T182T182T213T184T184T215T213T213T254T215T215T256T254T254T284T256T256T286T

284TS284T324T

286TS286T326T

324TS324T365T

326TS326T365T

364TS364T404T

365TS365T405T

405TS405T444T

444TS444T445T

445TS445T447T

447TS447T449T

449TS449T449T

449TS449TS449

S449SSS449

S449SSS449

NoLoad0.61.01.00.91.41.51.11.61.61.62.02.41.83.03.82.94.35.93.35.57.05.08.0

11.07.49.5

13.08.011149.5121512151815192419212822253419303932454837525944707345908668

12011668

13080

140

FullLoad1.31.51.61.92.22.32.42.82.93.64.04.35.76.46.98.69.5

10.511.412.513.8171921232427293033343539454649555862686874858593

108113117138143144164170172216226227269281281323346342372392422454

LckdRotor

111211171920232224323232464646646464818181

116116116145145145183183183218218218290290290363363363435435435543543543725725725908908908

1085108510851450145014501825210020502200220024002550280029002900

kVA/HP

CodeKLKLLMLKLKKKJJJHHHHHHGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGHHGGHGHGG

1/278.7%82.0%79.4%83.0%83.8%83.3%84.4%84.0%86.0%84.3%86.9%86.5%88.0%88.9%87.8%88.7%90.2%89.3%89.7%91.3%89.9%89.5%92.0%90.9%90.3%93.1%91.2%92.0%93.5%92.7%92.0%93.9%93.1%94.0%94.0%94.0%94.1%94.8%94.0%93.8%95.2%94.2%93.7%95.6%94.7%94.6%95.8%95.1%94.5%95.4%95.1%94.8%95.7%95.6%95.3%96.2%95.6%95.7%96.1%95.7%95.2%96.1%96.0%95.8%95.8%94.6%96.0%

3/481.9%84.8%82.2%85.3%86.2%86.3%86.4%86.4%88.1%86.5%89.0%89.0%89.1%89.9%89.2%90.4%91.6%90.9%90.7%92.1%91.2%91.1%92.6%91.8%91.2%93.3%92.0%92.2%94.0%93.2%92.2%94.1%93.5%94.1%94.3%94.4%94.2%95.0%94.3%94.1%95.4%94.7%94.3%95.8%94.9%94.7%96.0%95.3%95.1%95.6%95.4%95.2%96.0%96.0%95.6%96.5%96.2%96.0%96.3%96.0%95.8%96.3%96.1%96.1%96.3%96.1%96.4%

FullLoad

82.5%85.5%82.5%85.5%86.5%87.5%86.5%86.5%88.5%86.5%89.5%89.5%88.5%89.5%89.5%89.5%91.7%91.0%90.2%91.7%91.0%91.0%92.4%91.7%91.0%93.0%91.7%91.7%93.6%93.0%91.7%93.6%93.0%93.6%94.1%94.1%93.6%94.5%94.1%93.6%95.0%94.5%94.1%95.4%94.5%94.1%95.4%95.0%95.0%95.4%95.0%95.0%95.8%95.8%95.4%96.2%95.8%95.8%96.2%95.8%95.8%96.2%95.8%95.8%96.2%95.8%96.2%

GuarnMin

81.5%84.0%81.5%84.0%85.5%86.5%85.5%85.5%87.5%85.5%88.5%88.5%87.5%88.5%88.5%88.5%91.0%90.2%89.5%91.0%90.2%90.2%91.7%91.0%90.2%92.4%91.0%91.0%93.0%92.4%91.0%93.0%92.4%93.0%93.6%93.6%93.0%94.1%93.6%93.0%94.5%94.1%93.6%95.0%94.1%93.6%95.0%94.5%94.5%95.0%94.5%94.5%95.4%95.4%95.0%95.8%95.4%95.4%95.8%95.4%95.4%95.8%95.4%95.4%95.8%95.4%95.8%

1/271%52%48%73%53%49%74%56%55%77%59%54%83%65%56%78%66%55%81%66%56%83%67%53%81%69%57%80%71%62%84%73%64%80%75%70%82%74%67%80%77%65%81%78%68%90%80%73%84%78%74%84%78%73%88%76%75%89%80%81%86%75%82%89%77%89%77%

3/482%65%61%83%66%62%85%69%67%88%72%66%89%76%68%87%76%67%88%77%68%89%77%66%87%79%69%85%80%72%89%82%73%87%83%79%89%82%76%86%85%76%86%85%77%92%86%81%88%84%82%89%84%82%90%84%83%91%85%86%90%82%85%91%84%92%84%

FullLoad88%73%69%88%74%70%90%77%74%90%79%73%92%82%75%91%81%75%91%82%75%91%81%73%90%83%76%88%84%76%90%85%77%89%86%81%91%85%80%88%87%80%88%87%80%92%87%84%89%86%85%90%86%85%91%86%86%91%87%87%91%84%86%92%86%93%86%

Full Ld[Lb-Ft]

1.53.04.52.34.56.73.06.08.94.59.0137.515221121331530452245673059893774

1114589

13360

11817774

14822289

177266111221332147295443184368554220441662294588883368735

1104441882

1329515

1029588

1176

LockedRotor230%275%220%270%260%290%280%260%280%280%260%250%260%260%220%220%210%160%220%210%170%190%200%150%180%200%150%160%180%170%160%180%170%150%180%190%150%170%190%160%180%180%160%180%180%120%180%160%120%160%160%120%150%140%120%160%125%120%140%120%100%120%105%80%

100%80%

100%

Break-Down360%400%310%400%400%460%400%380%440%360%320%300%320%320%320%320%290%260%290%290%260%260%260%240%260%270%240%250%250%240%250%250%220%250%230%220%250%230%220%250%240%220%260%240%220%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%200%

Nominal Efficiency TorquePower FactorCurrent (A)

Minimum Guaranteed Full Load Efficiencies are based on NEMA MG1-12.54 10% Loss Difference.

Siemens Energy & Automation, Inc. Tel: 800-964-41143333 Old Milton Parkway, Alpharetta, GA 30005 www.sea.siemens.com

© 2004 Siemens Energy & Automation, Inc.NMFL-01902-0204 Printed in USA

Typical performance data shown. For certified data, contact Siemens.