MULTISET PRO - PRESET DIMMING SYSTEM INSTALLATION AND OPERATIONS MANUAL Integrated 13-Scene Preset Dimming System FOR USE WITH MODELS: Strap Models: MSP5, MSP5ES, MSP8, MSP8ES, MSPR, MSP5AV, MSP600VA, MSP600EB, MSP600ND, MSP600HDF120, MSCR, M4C, M4CR, MSP300QE, MSP300ESI, MSP8AV, MSP8AVES, MSP5AVES Heatsink Models: MHP5, MHP5ES, MHP5AV, MHP5AVES, MHP8, MHP8ES, MHP8AV, MHP8AVES, MHPR, MHCR, MHP600VA, MHP600EB, MHP1000VA, MHP1000EB, MHP1500VA, MHP2000VA, MHP600HDF120, MHP1500HDF120, MHP500QE, MHP500ESI, MHP1500EB, MHP1000ND, MHP2000ND Important: Retain These Instructions For The End User. DO NOT THROW AWAY! Classic Series Ellipse Series Additional information can be found at www.lolcontrols.com

Transcript of Series 13-Scene Preset Dimming System

Page 1: Series 13-Scene Preset Dimming System

MULTISET PRO - PRESET DIMMING SYSTEM

INSTALLATION AND

OPERATIONS

MANUAL

Integrated

13-Scene Preset

Dimming System

FOR USE WITH MODELS:

Strap Models:MSP5, MSP5ES, MSP8, MSP8ES, MSPR, MSP5AV, MSP600VA, MSP600EB, MSP600ND, MSP600HDF120,MSCR, M4C, M4CR, MSP300QE, MSP300ESI, MSP8AV, MSP8AVES, MSP5AVES

Heatsink Models:MHP5, MHP5ES, MHP5AV, MHP5AVES, MHP8, MHP8ES, MHP8AV, MHP8AVES, MHPR, MHCR,MHP600VA, MHP600EB, MHP1000VA, MHP1000EB, MHP1500VA, MHP2000VA, MHP600HDF120,MHP1500HDF120, MHP500QE, MHP500ESI, MHP1500EB, MHP1000ND, MHP2000ND

Important: Retain These Instructions For The End User. DO NOT THROW AWAY!

ClassicSeries

EllipseSeries

Additional information can be found at www.lolcontrols.com

THREE YEAR LIMITED WARRANTY

Page 2: Series 13-Scene Preset Dimming System

2

MULTISET PRO - PRESET DIMMING SYSTEM

Read Before Beginning Installation

1. All MultiSet Pro devices require a neutral connection (no common neutrals). Each circuit feeding dimmers and dimmed loads requires a separate neutral. Shared neutrals will result in undesirable flashing of controlled loads.

2. Use Quiet Electronic (QE) dimmers to control only low-voltage fixtures that have electronic, solid-state transformers and regular incandescent loads.

3. Use HDF Direct drive dimmers to control fluorescent lighting loads at 120V with approved Philips HDF Electronic Ballasts only.

4. Use Electronic Ballast (EB) Direct Drive Dimmers to control Advance Mark X® Dimmable Electronic Ballast.5. Use Energy Savings Inc. (ESI) to control ESI DIM-E Electronic Ballast.6. 120 volt MultiSet Pro Strap Dimmers (MSP), Masters, Switches, and Remotes mount individually or ganged

together and are supplied without faceplates. They accept Philips Controls single and multi-gang Compli Faceplates or standard decorator-style faceplates by others. Faceplates are not provided.7. MultiSet Pro Heatsink (MHP) Dimmers, Masters, Switches, and Remotes incorporate low-profile heatsinks and

are supplied with coordinating, beveled-edge faceplates. They mount side-by-side with no fins broken and do not need to be derated. They cannot be ganged with Strap devices. When mounting devices with one or both fins removed, it is necessary to derate the maximum load of the devices, however, this is not recommended. Refer to derating chart on page 15.

8. MultiSet Pro Dimmers or Switches may be fed individually or in groups, regardless of phase.9. MultiSet Pro Masters draw approximately one watt and may be fed from any circuit. Multiple masters

may be inter-connected. The total number of dimmers and masters are not to exceed 30. An unlimited numberof channel remotes (MSCR) may be used.

10. Dimmers can be connected to DA or HDF interface and amplifiers. Please consult interface and amplifier instructions for wiring. Non-dim switches can be connected to MultiSet relay modules for 277V loads.

11. Line voltage must not be supplied by a GFI breaker.

Caution

Caution: Be sure that power to the load being controlled has been disconnected by removing fuse or turning

circuit breaker off. Installing MultiSet Pro dimmers or Masters with power on may expose you to dangerous

voltage and damage the device.

Description

MultiSet Pro is a revolutionary system of advanced digital wallbox dimmers for economical and flexible

multi-scene, multi-channel control. MultiSet Pro provides flexible 13-scene preset dimming control of up to 30

devices as well as 12 adjustable fade rates up to one hour that are programmable by scene.

Wiring

MultiSet Pro utilizes standard 3-wire + ground wiring techniques. See wiring diagrams at the back of this booklet

for details.

Page 3: Series 13-Scene Preset Dimming System

3

Installation and Operation

Installation Instructions

MULTISET PRO DIMMER/SWITCH

CAUTION: Be Sure that power is disconnected to avoid damage to unit and shock hazard to installer.1. If you are replacing an existing device with a MultiSet Pro Dimmer or Remote:

A. Remove faceplate from existing deviceB. Unscrew and pull device out of wallbox.C. Disconnect wires from device. Using a voltage tester, identify and mark the "hot" and the "load" wires

connected to the device.2. If using Compli screwless faceplate (sold separately), before connecting any wires, be sure that the Compli

faceplate mounting adapter plate is behind the device with alignment tabs facing forward. Tabs should rest within centering holes of aluminum mounting strap.

3 Be sure MultiSet Pro Dimmer or Switch is in "System Off" position by firmly pressing bottom of device until it snaps into place and the "System Off" label at the top of device is exposed.

4. Connect the MultiSet Pro Dimmer/Switch wires to the Wallbox wires as follows:A. Black to Hot (120V AC Source)B. White to Neutral*C. Red to Load (Light Fixture)D. Yellow to Remote (MSCR/M4CR)** Cap yellow if MSCR/MHCR is not used.E. Purple to Network Connection (Line Voltage Class 1)***

5. Be sure the Ground wire (bare stranded) is connected to earth ground. Note: Miswiring or failure to connect ground may result in improper operation of the device.

6. Ensure all wire connections are tight and no bare copper is exposed.7. Install device into wallbox, making sure that all wires are neatly installed into wallbox. Using mounting

screws provided, secure device into wallbox.8. Install faceplate.

* The White wire must be connected to the neutral wire in the wallbox. Failure to connect the White wire to the neutral will result in improper operation.

** Consult MSCR/M4CR Instructions for wiring information.*** Link all MultiSet Pro devices using one line voltage wire connected between each Purple wire. Connected

devices will operate as a system.

Figure A

Page 4: Series 13-Scene Preset Dimming System

MULTISET PRO - PRESET DIMMING SYSTEM

4

MULTISET PRO MASTER

MSP5(AV), MSP5(AV)ES, MHP5(AV), MHP5(AV)ES, MSP8(AV), MSP8(AV)ES,MHP8(AV), AND MHP8(AV)ES

1. Caution: Be sure that power is disconnected to avoid damage to unit and shock hazard to installer.2. If using Compli screwless faceplate (sold separately), before connecting any wires, be sure that the Compli

faceplate mounting adapter plate is behind the device with alignment tabs facing forward. Tabs should rest within centering holes of mounting strap.

3. Connect the MultiSet Pro Master wires to the Wallbox wires as follows (Figure B):A. Black to Hot (120V AC Source)B. White to Neutral*C. Purple to Network Connection (Line Voltage Class 1)***

4. Be sure the Ground wire (Green) is connected to earth ground. Note: Failure to connect ground properly may result in improper operation or damage to unit. NOTE: Ellipse Series strap masters do not have a ground wire. Ellipse Series heatsink masters have a bare wire, which must be connected to ground.

5. For the AV Masters see the chart (Figure C) for wiring to other devices.6. Ensure all wire connections are tight and no bare copper is exposed.7. Install device into wallbox, making sure that all wires are neatly installed into wallbox. Using mounting

screws provided, secure Master into wallbox.8. Install faceplate.

* The White wire must be connected to the neutral wire in the wallbox. Failure to connect the White wire to the neutral will result in improper operation.

*** Link all MultiSet Pro devices using one line voltage wire connected between each Purple wire. Connected wires will operate as a system.

Installation Instructions

Figure B

Page 5: Series 13-Scene Preset Dimming System

5

Installation and Operation

Replacing the Keypad Button Labels (Classic Series)

MultiSet Pro Classic Series Masters are supplied with over 260labels to personalize the buttons for your own scene names. The buttons are labeled at the factory with letters. These button labels can easily be changed to customize yoursystem:1. Insert a small screwdriver into the outside edge on

the side of a button and pry off the plastic key cover. Caution: Pry from outside edge, do not attempt to insert screwdriver between key covers. (Figure D)

2. Remove the factory label and insert an appropriate label from the supplied label sheet into the key cover.

3. Snap the cover over the button housing by pressing firmly on the plastic key cover.

4. Repeat for each button you wish to change.

Figure D

Figure C

Page 6: Series 13-Scene Preset Dimming System

MULTISET PRO DIMMER

• To turn light on to preset level tap top of rocker. The dimmer will fade up at the 1.5 second rate.• A second tap of the rocker fades the dimmer to full brightness.• To adjust the light level, press and hold top or bottom of rocker until desired light level is reached,

and then release. Ramping will be at the 3 second rate.• To turn lights off, tap the bottom of the rocker. The dimmer

will fade at the 3 second fade rate. • To quickly return to the preset level when light is on, quickly tap OFF

and then ON. The lights will then adjust to the preset level.• To bypass the fade rate and turn the lights to full ON or OFF, double

tap the dimmer for ON or OFF.• If the master is in the OFF scene, the master ON button will illuminate

when any dimmer is turned on.• To change the preset level of the current scene:

• Press and hold the rocker until lights reach the desired level then release

• Press the set button to save the preset in memory

LEDs on the MultiSet Pro Dimmer/Switch indicate status:1. Red LED is on when Dimmer/Switch is off to locate Dimmer/

Switch when room is dark2. As many as 3 green LEDs may be illuminated at any given time.

The bright green LED indicates the current level of the dimmer. The medium green LED indicates the preset level of the current scene. The dim green LED indicates the preset level of the ON scene.

6

MULTISET PRO - PRESET DIMMING SYSTEM

Replacing the Keypad Membrane (Ellipse Series)

The overlay on these models is easily replaced, even if the unit iscurrently installed.

1. Turn the power off at the circuit breaker.2. Remove the faceplate (Figure E).3. Remove the master keypad wall screws (Figure F).3a. On Heatsink model, remove Heatsink screws and spacers

(Figure F).4. Remove the retaining plate screws and plate (Figure G).5. Remove the existing keypad membrane.6. Install the new keypad membrane, being careful to line it

up properly with the openings.7. Reinstall the retaining plate screws (Figure G).7a. On Heatsink model, reinstall screws and spacers (Figure F).8. Reinstall the master keypad to wallbox (Figure F).9. Reinstall the faceplate (Figure E).10. Turn the power back on at the circuit breaker.

Note: Spacers on the Heatsink model are not attachedto the unit.

Figure F Figure G

Figure E

Dimmer/Switch Operating Instructions

Page 7: Series 13-Scene Preset Dimming System

7

Installation and Operation

MULTISET PRO UNIVERSAL ELECTRONIC SWITCH (NON-DIM)The MultiSet Pro Universal programmable switch can be programmed as a four or five-scene non dim switch. When programmed as a five-scene device, it is not suitable for 3-way applications.

The default mode of the switch is as a normal (4-scene) non-dim device. The AV (5-scene) mode allows the non-dimswitch to remain off when the master ON button is pressed.

To change the mode of the switch:1. Tap OFF on the Master to place the switch in the OFF scene.2. Press and hold the set button (Step 2, pg. 8). After 3 Seconds, a green LED will illuminate on the bargraph.

If the switch is currently in normal mode, the bottom green LED will illuminate. If it is in AV mode, the top LED will illuminate.

3. Tap the top of the rocker once to toggle the mode.4. Release the set button.

Note: In normal mode, a “soft start” feature is utilized to extend bulb life. In AV mode, the “soft start” is not implemented.

Programming Scenes

After you have completed installation of all of the MultiSet Prodevices and have energized the system, programming of each scenecan be performed. Programming is as simple as 1, 2, 3!

1. Tap the preset button (ON, A – L) on the MultiSet Pro Master that you wish to program (See step 1)

2. Adjust each MultiSet Pro Dimmer to the desired intensity and the MultiSet Pro Switches to either ON or OFF.* (See step 2, pg. 8)

3. Press the Set button on each device (See step 3, pg. 8) after all devices have been adjusted.

Repeat Steps 1-3 until all scenes have been programmed.

*Note: Dimmers cannot be programmed off for the “ON” preset. Non-dim switches may be programmed “OFF”, see page 8 for details.

Step 1

Page 8: Series 13-Scene Preset Dimming System

8

MULTISET PRO - PRESET DIMMING SYSTEM

Changing the Fade Rate

Figure 2

Setting the Button Brightness (Ellipse Series)Each Ellipse Master Control Station button brightness can be programmed for100% (factory default), 75%, 50%, or 25% brightness. To change the setting:

1. On a 5-scene master, press and hold buttons “B” and “D” simultaneously for 3 seconds (on an 8-scene master, press buttons “H” and “J”). On a 5-scene master, buttons “A” thru “D” will illuminate (on an 8-scene master, buttons “G” thru “J” will illuminate). The blinking LED displays the current LED brightness setting. The continuously-illuminated LEDs display the available brightness settings that can be selected.

2. To change the brightness setting, press the button illuminated at the desired brightness. This button will begin blinking.

3. To save the selected brightness and exit the mode, press the ON button on a 5-scene master ( or the “E” button on an 8-scene master). All buttons on that master will now have the new brightness setting.

5-Scene 8-Scene LEDMaster Master Brightness

A G 100%B H 75%C I 50%D J 25%

MultiSet Pro Dimmers can be programmed for 12 different fade rates. Dimmers can be programmed tohave a different fade rate on each scene.

The fade rate choices are:1.5 seconds 1 minute3 seconds 2 minutes4.5 seconds 5 minutes7.5 seconds 15 minutes15 seconds 30 minutes30 seconds 60 minutes

Global Fade Rate = One fade rate for all scenes.Each dimmer’s fade rate affects all scenes. Example:Dimmer #1 fade rate set 7.5 sec., dimmer #2 set to 15 sec., dimmer #3 set to 3 sec. When any scene is selected dimmers #1, 2, 3, will respond with 7.5, 15 and 3 seconds, respectively for ON, OFF, A, B, C, D, E, F, G, H, I, J, K and L.

To change the Global Fade Rate that affects all scenes:1. Tap the OFF Button on the Master.2. Press and hold the SET button. After 3 seconds, either

a single green LED or a pair of green LEDs will indicate the current "global" fade rate. The bottom LED indicates the 1.5 second fade rate, the next LED up is 3 seconds, ...the top LED is 2 minutes. If the bottom two LEDs are on, it indicates the 5 minute fade rate, if the next two LEDs up are lit, it indicates 15 minutes, ... the top two LEDs indicate the 60 minute fade rate.

Note: When the two LEDs are on, they will not be at the same intensity.

3. While holding the Set button, tap the top of the rocker to sequence the LEDs through the various fade rates until the desired fade rate is selected.

4. Release the SET button.5. Repeat steps 2-4 for each device.

To change the fade rate that will affect only an individual scene:1. Tap a scene button on the Master to go to a scene.2. Press and hold the SET button.3. After 3 seconds, either a single green LED or a pair

of green LEDs will indicate the scene's fade rate.4. While holding the Set button, tap the top rocker until

the desired fade rate is reached.5 Release the SET button.6. Repeat above for each device.

Page 9: Series 13-Scene Preset Dimming System

9

Installation and Operation

IR Receiver Programming

Ellipse masters with IR receivers can be programmed to operate in one offour IR modes, plus OFF. This allows up to four Master Control Stations tobe installed in close proximity to each other, but each controlling separateMultiSet Pro systems. The Master Control Stations are factory–programmedto OFF. To change the programming, follow the instructions below:

1. On the master, press and hold buttons A and C simultaneously for 3 seconds.

2. The current room programmed will blink on the master A,B,C,D or OFF (factory default).

3. Press the room button that you want to program [RM 1(A), RM 2(B), RM 3(C) or RM 4(D),OFF]. The button pressed will begin blinking.

4. Press the ON button to save the selected room (or OFF) and exit the programming mode.

Controlling MSP5ES / MHP5ES from Remote Control Units

CLMIRT This remote control transmitter always operates in ROOM 1 mode. Therefore, the master must be inROOM 1 mode to receive commands from the remote control.

CLMIRTES This remote control transmitter can operate in all four ROOM modes. On the transmitter, you must first press a ROOM button to place the transmitter in that mode. (example: pressing ROOM 2 sets the transmitter in ROOM 2 mode). The transmitter will then control any Master Control Station programmed to receive that same rooms commands.

Page 10: Series 13-Scene Preset Dimming System

10

MULTISET PRO - PRESET DIMMING SYSTEM

Operating Instructions

MULTISET PRO MASTER (CLASSIC SERIES)

• Tapping the ON button will elegantly illuminate the entire area to the ON "preset" (when an MSP5 is in scene E-L, the ON button will illuminate at 25% intensity). If a dimmer’s global fade rate is set between 1.5 and 7.5 seconds, the ON scene will ramp up at the 1.5 second rate. If the global fade rate is set for 15 seconds or greater, the ON scene will ramp at the 3 second rate.

• Press and hold the ON button to brighten lighting level. Ramping is at a 3 second rate.

• Tapping the OFF button will fade lights to OFF• Press and hold OFF button to lower lighting level. Ramping is at a 3

second rate.• Tap a scene button to access one of the "preset" light levels. The

ramp up time depends on the selected fade rate. (ON/OFF Master does not have this feature)• Two quick taps of any button (including ON and OFF) will fade the lighting quickly.

MULTISET PRO MASTER (ELLIPSE SERIES)

• Press or Tap the ON button to elegantly illuminate the entire area to theON "preset" (when an MSP5ES is in scene E-L, the ON button will illuminate at 25% intensity). If a dimmer’s global fade rate is set between 1.5and 7.5 seconds, the ON scene will ramp up at the 1.5 second rate. If the global fade rate is set for 15 seconds or greater, the ON scenewill ramp at the 3 second rate.

• Press and hold the RAISE/LOWER button to brighten/dim lighting level. Ramping is at a 3 second rate.

• Press or Tap the OFF button to fade lights to OFF• Tap a scene button to access one of the "preset" light levels. The

fade up/down time depends on the selected fade rate. • Two quick taps of any button (except RAISE or LOWER) will fade

the lighting quickly.• For information on the IR Receiver, see Infrared Receiver below.

Infrared Receiver

Ellipse Series 5-Scene Masters have an integrated infrared (IR) receiver that allows them to receive IR commands from a remote control unit (CLMIRT, CLMIRTES).

CLMIRTES

CLMIRT

The CLMIRTES infrared transmitter is capable of operating over an unobstructed range ofapproximately 25 feet. Within this range, scenescan be selected, raised and lowered, and lightingmay be turned On and Off using the handheldremote transmitter. In addition, the CLMIRTES is capable of controlling up to 4 differentMultiSet Pro control station groups.

NOTE: This system is based on line-of-sightoperations. Therefore, the receiver must be ableto “See” the transmitter. Any obstruction betweenthe transmitter and receiver may adversely affectthe performance of the unit.

See page 9 for additional CLMIRTES information.

Page 11: Series 13-Scene Preset Dimming System

11

Installation and Operation

Typical Layout Using High Wattage Dimmers with Masters

Wiring Diagrams

Multiset Pro AV Master (MSP5AV)

Wiring Notes: No common neutrals may be used between dimmed circuits of unlike phases. Purple wire is a line voltage carrier, observe wiring codes.Line voltage must not be supplied by a GFI breaker.

See page 5 Figure C

Page 12: Series 13-Scene Preset Dimming System

12

MULTISET PRO - PRESET DIMMING SYSTEM

Dimming Amplifier (DA22000VAI)

Wiring Notes: No common neutrals may be used between dimmed circuits of unlike phases. Purple wire is a line voltage carrier, observe wiring codes.Line voltage must not be supplied by a GFI breaker.

Direct Drive Fluorescent Dimming (HDF Dimmer)

Page 13: Series 13-Scene Preset Dimming System

Direct Drive Fluorescent Dimming (EB Dimmer)

13

Installation and Operation

Troubleshooting Guide

Total Ballast Quantity

Typical Dimmer

Wiring Notes: No common neutrals may be used between dimmed circuits of unlike phases. Purple wire is a line voltage carrier, observe wiring codes.Line voltage must not be supplied by a GFI breaker.

Page 14: Series 13-Scene Preset Dimming System

14

MULTISET PRO - PRESET DIMMING SYSTEM

Wiring Notes: No common neutrals may be used between dimmed circuits of unlike phases. Purple wire is a line voltage carrier, observe wiring codes.Line voltage must not be supplied by a GFI breaker.

Troubleshooting Guide

Total Ballast Quantity

Direct Drive Fluorescent Dimming (ESI Dimmer)

Page 15: Series 13-Scene Preset Dimming System

15

Installation and Operation

Ganging and Derating

HEATSINK DEVICES

No Fins Broken – Separate Wallboxes

Devices of matching depth can be mounted next to eachother in separate single gang wallboxes. The boxes mustbe spaced to the dimensions shown in Figure H. Allow 6”of clearance above and below the dimmers.

Note: For Precision Dimmers add 1/8” to each horizontaldimension shown in Figure H. Faceplate depth: 5/8”.

No Fins Broken – Multi-gang Wallbox

When mounting devices with no fins removed, use Table Ato determine what size multi-gang wallbox is required.

Note:1. When installing a even number of small devices, only

use wallbox size listed in Table A and space one additional box 3/4” away from the others.

2. When combining small and large devices, be certain to position a small device at one end and a large device at the other end of the multi-gang box.

3. Mount dimmers with heatsink fins aligned vertically.

Fins Broken – Multi-gang Heatsink Wallbox

When mounting devices with fins broken in multi-gangboxes, follow information in Table B to determine the correct wallbox size.

Fins Broken – Derating

When mounting devices with one or both fins removed it isnecessary to derate the maximum load of the devices inaccordance with the FINS BROKEN–DERATING CHART inTable C.

Page 16: Series 13-Scene Preset Dimming System

Exchange of products covered by warranty should be handled through your original supply source.

Philips Controls2828 Trade Center Drive, Suite 130B • Carrollton, Texas 75007

For technical/sales assistance call: 1-800-526-2731

Made in U.S.A. ©Philips Controls 1999

www.lolcontrols.com P/N 85-6265

MULTISET PRO - PRESET DIMMING SYSTEMInstallation and

Operation

Specifications

Voltage: Input: 108-132 VAC, 60 Hz, ±3Hz

Operating Temperature: 0-40Þ Centigrade

Load: VA dimmers: Incandescent, low voltage incandescent with magnetic transformers, neon, cold cathode, or general inductive loads. Neutral connection required.

ND controls: Switched loads. Neutral connection required.

QE dimmers: Electronic low voltage and incandescent loads. Neutral connection required.

ESI dimmers: ESI reverse phase electronic ballast. Neutral connection required.

HDF dimmers: Fluorescent lighting loads with approved Philips HDF Electronic Ballasts. Neutral connection required.

EB dimmers: Fluorescent loads with Advance Mark X® electronic ballasts. Neutral connection required.

We reserve the right to change details of design, materials and finish, in any way that will not alter installed appearance orreduce function performance.

Dimensions

MSP-Series Masters/Dimmers/Remotes MHP-Series Masters/Dimmers/Remotes

Classic or Ellipse Series Classic or Ellipse Series Master500W, 600W, 1000W Dimmers 1500W, 2000W Dimmers

THREE YEAR LIMITED WARRANTYThe Philips Controls product, when properly installed and under normal conditions of use (without overload, abuse or alteration), is warrant-ed to you, the original user, for a period of three years form the date of original retail purchase, to be free from defects in materials and work-manship. If during the warranty period you believe the purchased product or any part thereof has such a defect, you must return the product(or part) at your cost during such period, with proof of purchase (or if installed by a third-party a written explanation of installation transac-tion with proof of date), to Philips Controls, 2828 Trade Center Dr. Ste. 130B, Carrollton,TX 75007, for repair or replacement (or to an autho-rized Philips Controls supplier which agrees in advance to handle the return and replacement by factory authorization). If the product or partis found by Philips Controls to have been defective in material or workmanship it will be repaired or replaced (as deemed necessary by PhilipsControls), and the replacement will be returned to you free of charge.The original user is solely responsible for any costs associated withremoval and re-installation of the product and shipping to Philips Controls or its authorized supplier.PHILIPS CONTROLS LIMITS THE DURATION OF THE IMPLIED WARRANTY OF MERCHANTABILITY WITH RESPECT TO THE PRODUCT TO THELIMITED WARRANTY PERIOD SET FORTH ABOVE,AND OTHERWISE DISCLAIMS ALL IMPLIED WARRANTIES WITH RESPECT TO THE PROD-UCT AND ITS PARTS. Some states disallow certain limitations on implied warranties so you should consult your state law if you have a ques-tions regarding this limitation and disclaimer.Philips Controls disclaims any and all liability for incidental,consequential, special or indirect dam-age arising out of any claimed breach of warranty or otherwise. However, some states do not allow exclusion or limitation of such damages, sothis disclaimer may not apply to you.The remedy provided in the Limited Warranty for defective products is the user’s sole and exclusive remedy, subject to your state law. Further,this Warranty gives the user specific legal rights, and the user may also have other rights which may vary from state to state.If you believe warranty claim is warranted, you may contact your nearest authorized Philips Controls supplier. If one does not exist in yourarea, please contact Philips Controls Customer Service at the above address (or at 1-800-526-2731), or please visit us at www.lolcontrols.com.