SECURITY, ACCESS CONTROL, AND OSDP T ( ( ( ' : T 7 2...Suprex® Supervised Reader-Extenders (Wired &...
Transcript of SECURITY, ACCESS CONTROL, AND OSDP T ( ( ( ' : T 7 2...Suprex® Supervised Reader-Extenders (Wired &...
WIRELESS READERS
READER - EXTENDERS
MADEIN THEUSA
OSDP™ ANDCUSTOM SOLUTIONS
DATA PROTOCOL ANDFORMAT CONVERTERS
T T
SECURITY, ACCESS CONTROL, AND OSDP™
If you’re in access control,
you know your reputation is
only as strong as the solutions
you provide your clients.
solutions every access control practitioner needs.Along with Cypress custom solutions, here is a sampling of
4
6
7
8
9
10
11
Suprex® Supervised Reader-Extenders (Wired & Wireless)
OSDP™ Converters OSMIUM™ Series
Wireless Handheld Readers
Wiegand Splitters
Data Converters
More Access Control Solutions
Product Numbers & Custom Solutions
Suprex®Supervised Reader-Extender
4
Connect readers to access controllers using existing RS-485,
Ethernet, or fiber optic†
Connect readers to panels in isolated locations without
buying a second control panel
Overcome Wiegand distance limitations using existing cable•
RS-485 models provide high immunity to electrical noise under
adverse conditions, such as elevator installations
Wired Suprex®
SPX-5631
SPX-1300
•
•
•
Install readers without trenching or disturbing
buildings with asbestos or historical significance
Wirelessly overcome Wiegand distance limitations†
† Typical Suprex ranges, depending on environment: RS-485, 1219 m (SPX-7500) – 3048 m (SPX-1300); Multi-mode fiber optic, 3.21 km;
Single-mode fiber optic, 38.62 km; Wireless short-range without repeater, 1524 m; Wireless long-range without Repeater, 3048 m; Repeater, 1524 m
Install readers across parking lots,
railroad tracks, or in other buildings
Wireless Suprex®
•
•
•
Traditional installation with 10+ wires between door
or gate & control panel.
Wired Suprex installationwith existing cable between
Suprex Remote & Central
units, connected to reader
& access control system.
Wireless Suprex installation with wireless signal
connecting Suprex Remote &
Central units, connected to
reader & access control system.
5
OSDP™ ConvertersUpgrade to SIA's Powerful, Secure Standard
SIA's Open Supervised Device
Protocol access control standard
Started by HID Global & Mercury
Security Corporation
Transferred to the Security Industry
On track to become an IEC
ininternational standard
Expected to replace Wiegand
interface
OSDP upgrade products on the
market since 2015
Functionality: Uses 2 wires instead of 10+, allows for multi-drop installations, 2-way communication
for sophisticated processing and
supervision
Interoperability: Mix & match components to help future-proof
systems
Security: OSDP Secure Channel protects access control systems from
hacking
OSDP-Wiegand Converter: converts Wiegand to OSDP and OSDP to Wiegand
(OSM-1000)
Other OSDP Converters: Ask about Cypress Ethernet, fiber optic, and wireless OSDP
solutions
OEM Development Kits also available
Why How
•
•
•
•
•
•
What
6CypressIntegration.com/OSDP
WirelessHandheld Credential Reader
HHR-3166-GY
Handheld wireless reader for rapid disaster deployment,
random screening, mustering, in-vehicle credential checks,
staff enrollment, and security officer empowerment.
Multiple credential technologies available.
See the video at CypressIntegration.com/handheld-wireless-reader
The handheld reader verifies credentials by wirelessly communicating with a live database through the reader's base unit. The handheld unit can
control a relay for functions such as opening doors or gates, or
triggering possible duress notifications.
Choose a single reader kit, 2-reader kit, or the gate-selection reader with a
2-Wiegand output base unit. See credential technologies, page 11.
Typical wireless range without repeaters: 45.7 m indoors / 152.4 m
ououtdoors, depending on environment.
7
CVX-OPTS
CVX-OPTW
It can also be used between devices with different Wiegand voltage levels.
It can connect 1 reader with 2 panels sharing the same data.
Also available: The Intelligent Wiegand Splitter is custom-engineered to connect a reader with 2 panels and routedata to the appropriate panel. Use in multi-tenant appliapplications.
The Passive Wiegand Splitter connects 2 readers with one panel using the same Wiegand port.
READER
READER
READER
PANEL
PANEL
OPTW
OPTW
READER OPTW
PANEL
PANEL
WiegandSplitters
8
Data Converters
See manual for specific format conversions
Cypress Data Converters allow integration of new or nontraditional devices with existing or traditional devices.
Custom Data Converters are also available.
CVX-1300
The Multi-Format Data Converter enables dozens of field-selectable conversions.
Examples of input/output interfaces: Examples of input/output protocols/encoding formats:
• Wiegand• Strobed (Clock & Data)• RS-232• RS-485• Other specified interface
• Binary encoding • ABA encoding• ASCII encoding• Specified Wiegand• Other specified protocol/encoding
9
10
WDG-5912
TSP-3100
CCK-3104
Connects to a badge reader and plugs into a computer
USB port, then "types" badge data into an Excel file or
other software emulating keyboard keystrokes. Allows
collection of badge data, similar to control panel. Useful
for debugging and time or attendance.
Data Wedge
Pairs a pre-configured Data Converter and scanner
to convert barcodes or QR codes to Wiegand.
Recommended for visitor lobby, time & attendance,
turnstile, parking, and point-of-sale applications.
Barcode scanner kit
Synchronizes access control panel with displayed
time to prevent labor issues. Time drivers
and time display components are available.
Time Display series
More Access Control Solutions
Product Numbers
11
For custom solutions, go to CypressIntegration.com/support
Cypress access control solutions
are built with 35+ years of industry
expertise, right here in the U.S.A.
©2019 Cypress Integration Solutions
CypressIntegration.com