SEALED CONNECTORS FOR THE LS SERIESus.azbil.com/CP-GC1003E_Vol.1_a_c/D/SEALED_CONNECTORS.pdf ·...

8
SEALED CONNECTORS FOR THE LS SERIES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications PA1 Series Zinc alloy Brass Zinc alloy SUS Brass Zinc alloy Copper SUS Brass High strength Harsh environment resistance Corrosion resistance, oil resistance Heat-resistance, cold resistance High strength Harsh environment resistance Cable protection Vibration resistance High tensile strength High sealability High strength Harsh environment resistance Cable protection Vibration resistance High tensile strength High sealability High strength Harsh environment resistance High sealability Machine tools Automobile manufacturing facilities Conveying machines Valves Plants Presses Robots Presses Machine tools Conveyors Robots Presses Machine tools Conveyors Machine tools Valves Plants Automobile manufacturing facilities (welding lines) PA3 Series Cable lead-out type Locations constantly subject to splashing by cutting fluid (outstanding oil resistance and cold and heat resistance) Outdoor use Nut with protective wire mesh cable grip for cable lead-out Locations where there is a risk of chips, etc. damaging the cable Locations where the cable constantly moves or is bent due to machine operation Single piece Can be mounted on sealed connector already in use Locations where pulling and bending forces are exerted on cables and flexible conduits Flexible conduit mounting type Locations requiring cable protection Locations requiring flexible tubing PA1- G Series PA1- G 1

Transcript of SEALED CONNECTORS FOR THE LS SERIESus.azbil.com/CP-GC1003E_Vol.1_a_c/D/SEALED_CONNECTORS.pdf ·...

  • SEALED CONNECTORS FOR THE LS SERIES

    LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches.

    Type and appearance Materials Features Target market Applications

    PA1 Series

    Zinc alloy

    Brass

    Zinc alloy

    SUS

    Brass

    Zinc alloy

    Copper

    SUS

    Brass

    High strength

    Harsh environmentresistance

    Corrosion resistance,

    oil resistance

    Heat-resistance,

    cold resistance

    High strength

    Harsh environmentresistance

    Cable protection

    Vibration resistance

    High tensile strength

    High sealability

    High strength

    Harsh environmentresistance

    Cable protection

    Vibration resistance

    High tensile strength

    High sealability

    High strength

    Harsh environmentresistance

    High sealability

    Machine tools

    Automobilemanufacturingfacilities

    Conveying machines

    Valves

    Plants

    Presses

    Robots

    Presses

    Machine tools

    Conveyors

    Robots

    Presses

    Machine tools

    Conveyors

    Machine tools

    Valves

    Plants

    Automobilemanufacturingfacilities

    (welding lines)

    PA3 Series

    Cable lead-out type

    Locations constantly subject to

    splashing by cutting fluid

    (outstanding oil resistance and cold and

    heat resistance)

    Outdoor use

    Nut with protective wire mesh cable

    grip for cable lead-out

    Locations where there is a risk of chips,

    etc. damaging the cable

    Locations where the cable constantly

    moves or is bent due to machine

    operation

    Single piece

    Can be mounted on sealed connector

    already in use

    Locations where pulling and bending

    forces are exerted on cables and

    flexible conduits

    Flexible conduit mounting type

    Locations requiring cable protection

    Locations requiring flexible tubing

    PA1-����G Series

    PA1-�G

    1

  • PA1 SERIES SEALED CONNECTORS

    Sealed connectors for cables connected to limit switches. Can be used with protective stainless steel wire mesh cable grip.

    ORDER GUIDE

    MATERIAL AND APPLICABLE MODELS

    *1. O-rings are not provided with NPT thread type.*2. The material of NPT thread and PG screw-type nipples is free-cutting brass on both standard types and cold/heat-resistant types.* NBR: nitrile rubber. CR: chloroprene rubber, SI: silicone rubber.

    PA1-A-D

    123

    10

    PFPTG1G2

    Blank

    NBR

    SI

    NBR

    Zinc alloy

    Zinc alloy

    Free-cuttingbrass

    Zinc alloy

    Zinc alloy

    Free-cuttingbrass

    NBR

    SI

    CR

    Polyamide resin

    Free-cutting brass

    Polyamideresin

    Cable lead-out type sealed connector

    Straight

    Elbow (90˚)

    For cable 4 to 8 mm in dia.

    For cable 8 to 12 mm in dia.

    For cable 12 to 16 mm in dia.

    For cable 6 to 10 mm in dia.

    Compatible only with screw nominal diameters PF and PT.

    G (CTG16)

    NPT

    PG9

    PG11

    PG13.5

    Standard (oil-resistant) model (–20 to +70˚C)

    Cold- and heat-resistant (–40 to +120˚C)

    Corrosion-resistant (–20 to +70˚C)

    Without wire mesh cable grip

    With wire mesh cable grip(not compatible with cable O.D. 10)

    G

    MH

    Blank

    G3

    Basic cataloglisting

    ShapeCable O.D.

    Screw nominal

    dimension

    Environmental specifications

    Additionalspecifications

    Description

    Compatible only with

    shape code A.

    Model selection guide : Example:PA1-A1PF

    Component O-ring*1 Nipple*2 SealbushingTaperedwasher

    Tighteningnut Applicable models

    Standard(oil-resistant) model

    H (cold- and heat-resistant)

    M (corrosion-resistant)

    LS Series (excluding low- and high-temperature use and corrosion-resistant type)

    LS Series (low- and high-temperature use)

    LS Series (corrosion-resistant type)

    1 2

    1 2

    Cable lead-out type sealed connector.Straight and 90˚ elbow types available.Various conduit sizes and cable O.D.s are available.

    *All catalog listings for Azbil limit switches having screw nominal diameter codes PF (G1/2), G1, G2, and G3 (PG size) are custom-order products. For details, contact your dealer.

    1 2

  • POSSIBLE MODEL NO. COMBINATIONS AND EXTERNAL DIMENSIONS

    Compatible cable O.D. A max. C max.

    Catalog listingScrew

    nominal size BDist. betw. opposite flats

    Tightening nutNipple

    37

    42

    35

    35

    35

    37

    42

    34

    35

    41

    45

    38

    37

    42

    35

    34

    35

    8

    14

    8

    8

    8

    8

    14

    7

    8

    8

    14

    8

    8

    14

    8

    7

    8

    26

    26.4

    22

    26.4

    26.4

    26

    26.4

    26.4

    26.4

    30

    33

    33

    26

    26.4

    26.4

    26.4

    26.4

    24

    24

    20

    24

    24

    24

    30

    24

    20

    24

    30

    24

    4 to 8 mm in dia.

    8 to 12 mm in dia.

    12 to 16 mm in dia.

    6 to 10 mm in dia.

    PA1-A1PFPA1-A1PTPA1-A1G1PA1-A1G2PA1-A1G3PA1-A2PFPA1-A2PTPA1-A2G2PA1-A2G3PA1-A3PFPA1-A3PTPA1-A3G3PA1-A10PFPA1-A10PTPA1-A10G1PA1-A10G2PA1-A10G3

    G12(CTG16)

    NPT12

    PG9

    PG11

    PG13.5

    G12(CTG16)

    NPT12

    PG11

    PG13.5

    G12(CTG16)

    NPT12

    PG13.5

    G12(CTG16)

    NPT12

    PG9

    PG11

    PG13.5

    PA1-D���90˚ elbow type

    Compatible cable O.D. A max. C max.

    Catalog listingScrew

    nominal size BDist. betw. opposite flats

    Tightening nutNipple

    4 to 8 mm in dia.

    8 to 12 mm in dia.

    12 to 16 mm in dia.

    6 to 10 mm in dia.

    38

    43

    50

    43

    8

    8

    8

    8

    20

    24

    30

    24

    49

    44

    49

    53

    49

    24

    26

    24

    26

    30

    24

    26

    PA1-D1PFPA1-D1G3PA1-D2PFPA1-D2G3PA1-D3PFPA1-D3G3PA1-D10PFPA1-D10G3

    G12(CTG16)

    PG13.5

    G12(CTG16)

    PG13.5

    G12(CTG16)

    PG13.5

    G12(CTG16)

    PG13.5

    (unit: mm)

    (unit: mm)

    PA1-A���straight type

    3

  • Compatible cable O.D. A max. C max. D max.

    Catalog listing Screw nominal size B E

    Diameter d

    Dist. betw. opposite flats

    Tightening nutNipple

    (unit: mm)

    38

    42

    36

    36

    36

    38

    42

    36

    36

    41

    45

    38

    8

    14

    8

    8

    8

    8

    14

    8

    8

    8

    14

    8

    26

    27.7

    23.1

    27.7

    27.7

    26

    27.7

    27.7

    27.7

    30

    34.6

    33

    24

    24

    20

    24

    24

    24

    30

    20

    24

    30

    105

    125

    140

    F max.

    70

    90

    100

    8

    12

    16

    17

    17

    19

    4 to 8 mm in dia.

    8 to 12 mm in dia.

    12 to 16 mm in dia.

    G12(CTG16)

    NPT12

    PG9

    PG11

    PG13.5

    G12(CTG16)

    NPT12

    PG11

    PG13.5

    G12(CTG16)

    NPT12

    PG13.5

    8

    12

    16

    105

    125

    140

    70

    90

    100

    17

    17

    19

    (unit: mm)

    Compatible cable O.D. C max.

    Catalog listing Screw nominal size

    Dist. betw. opposite flats

    Tightening nutNipple

    4 to 8 mm in dia.

    8 to 12 mm in dia.

    12 to 16 mm in dia.

    A max.

    38

    43

    50

    B

    8

    8

    8

    20

    24

    30

    49

    44

    49

    53

    24

    26

    24

    26

    30

    G12(CTG16)

    PG13.5

    G12(CTG16)

    PG13.5

    G12(CTG16)

    PG13.5

    EDiameter

    dF max.D max.

    PA1-A���G straight sealed connector with wire mesh cable grip

    PA1-A1PF�GPA1-A1PT�GPA1-A1G1�GPA1-A1G2�GPA1-A1G3�GPA1-A2PF�GPA1-A2PT�GPA1-A2G2�GPA1-A2G3�GPA1-A3PF�GPA1-A3PT�GPA1-A3G3�G

    PA1-D���G 90˚ elbow sealed connector with wire mesh cable grip

    PA1-D1PF�GPA1-D1G3�GPA1-D2PF�GPA1-D2G3�GPA1-D3PF�GPA1-D3G3�G

    3 4

  • 1.Example of sealed connector assembly.

    2. Follow the procedure below to assemble the PA1-D Series 90 elbow connector (excluding NPT screw type).

    1 2 3 4

    After deciding the direction of the nipple, screw in only the seal nut until it is completely locked at the surface of the limit switch, so that the nipple is firmly tightened onto the limit switch body.

    Unscrew the nipple no more than 360˚ to position it in the desired direction.

    Screw in the nipple until it contacts the threads of the limit switch.

    Screw in the seal nut until it firmly contacts the nipple.

    PRECAUTIONS FOR USE

    5

  • The PA1-�G can be added onto the sealed connector (PA1 Series) after the connector is mounted on the limit switch. Attach the cable grip as shown below.

    Step 1. Loosen the tightening nut of the sealed connector.Step 2. Pull out the cable.Step 3. Remove the tightening nut of the sealed connector from the cable, and pass the cable through a cable grip of the

    appropriate O.D. instead.Step 4. Run the cable into the switch and wire it to the terminal.Step 5. Fully tighten the nut of the cable grip.

    ORDER GUIDE

    MATERIAL

    EXTERNAL DIMENSIONS

    ATTACHMENT OF WIRE MESH CABLE GRIP (example)

    Catalog listing Description

    Compatible cable outer dia. 4 to 8 mm

    Compatible cable outer dia. 8 to 12 mm

    Compatible cable outer dia. 12 to 16 mm

    PA1-1GPA1-2GPA1-3G

    Catalog listing

    Compatible cable O.D. A max. B C max. Compatible connector models

    4 to 8 mm

    8 to 12 mm

    12 to 16 mm

    105

    125

    140

    17

    17

    19

    Diameter d

    8

    12

    16

    E

    20

    24

    30

    70

    90

    100

    PA1-1GPA1-2GPA1-3G

    PA1-A1��� PA1-A2���PA1-A3���

    Component model No. Tightening nut

    Zinc alloy Free-cutting brass SUS304

    MeshGrip fastener

    PA1-�G

    PA1-G SERIES WIRE MESH CABLE GRIP

    (unit: mm)

    Nut with protective mesh for attachment to PA1 Series sealed connectors.

    Sealed cable grip can be added to cable lead-out type sealed connector that is already installed.Can be attached to either straight or 90˚ elbow connectors.Various types for different O.D. cables.

    PA1-D1���PA1-D2���PA1-D3���

    5 6

  • ORDER GUIDE

    Sealed connectors for flexible tubes (conduits) connected to limit switches. May be used with wire mesh grip to protect flexible tubes or conduits.

    14

    38

    12

    12

    34

    34

    Catalog listing A (approx.)Screw

    nominal size B CDist. betw. opposite flats

    PA3-A2PF-1PA3-A3PF-10PA3-A4PF-10PA3-A4PF-2PA3-A6PF-3PA3-A6P6-3

    12.3

    13.5

    14.3

    14.3

    15.4

    15.4

    D

    24

    24

    24

    24

    29

    36

    VF,SR,VH,FBN-02

    VF,SR,VH,FBN-03

    VF,SR,VH,FBN-04

    VF,SR,VH,FBN-04

    VF,SR,VH,FBN-06

    VF,SR,VH,FBN-06

    E

    24

    27

    30

    30

    36

    36

    F

    24

    27

    30

    30

    37

    37

    45.0 to 54.0

    46.5 to 56.0

    47.0 to 57.0

    47.0 to 56.0

    50.0 to 59.0

    50.5 to 59.5

    Flexible conduit nominal dia.

    12

    12

    12

    12

    12

    34

    CTG16(G )

    CTG16(G )

    CTG16(G )

    CTG16(G )

    CTG16(G )

    CTG22(G )

    8

    8

    8

    8

    8

    8

    (unit: mm)

    Flexible tube lead-out type sealed connector.

    Straight and 90˚ elbow types available.

    Various conduit sizes and screw nominal diameters available.

    Straight type

    Compatible conduit *flexible tube

    *Use flexible conduits/tubes made by Nippon Flex Co., Ltd.

    O-ring: NBRNipple: free-cutting brass

    Seal bushing: chloroprene rubber

    Taper washer: acetal resin

    Terminal cap: cold-rolled steel

    Seal: chloroprene rubber

    Combination nipple: free-cutting brass

    Sleeve: acetal resin

    Tightening nut: free-cutting brass

    PA3 SERIES SEALED CONNECTORS

    7

  • 14

    38

    12

    12

    34

    34

    Catalog listingA

    (approx.)

    Screw nominal size

    BC

    (approx.)

    Dist. betw. opposite flats

    PA3-D2PF-1PA3-D3PF-10PA3-D4PF-10PA3-D4PF-2PA3-D6PF-3PA3-D6P6-3

    31

    36

    36

    36

    38

    39

    D

    8

    8

    8

    8

    8

    8

    VF,SR,VH,FBN-02

    VF,SR,VH,FBN-03

    VF,SR,VH,FBN-04

    VF,SR,VH,FBN-04

    VF,SR,VH,FBN-06

    VF,SR,VH,FBN-06

    E

    24

    24

    24

    24

    29

    36

    F

    24

    27

    30

    30

    36

    36

    G

    24

    27

    30

    30

    37

    37

    48 to 58

    56 to 65

    56 to 66

    56 to 65

    63 to 70

    63 to 70

    Flexible conduit nominal dia.

    12

    12

    12

    12

    12

    34

    CTG16(G )

    CTG16(G )

    CTG16(G )

    CTG16(G )

    CTG16(G )

    CTG22(G )

    12.3

    13.5

    14.3

    14.3

    15.4

    15.4

    (unit: mm)90 elbow type

    Compatible conduit*flexible tube

    *Use flexible conduits/tubes made by Nippon Flex Co., Ltd.

    O-ring: NBR Nipple: brass castingSeal bushing: chloroprene rubber

    Taper washer: acetal resin

    Terminal cap: cold-rolled steel

    Seal: chloroprene rubber

    Combination nipple: free-cutting brass

    Sleeve: acetal resin

    Tightening nut: free-cutting brass

    Seal nut: free-cutting brass

    7 8