SCG 60 Manual
Transcript of SCG 60 Manual
-
8/2/2019 SCG 60 Manual
1/14
GSM E1 Channel Bank
(SCG-60)
User Manual
Technology Co., Ltd.
-
8/2/2019 SCG 60 Manual
2/14
Contents
1.INTRODUCTION ................................................................... 1
2.SYSTEM CONFIGURATION DIAGRAM ............................2
3.MECHANISM DIAGRAM.....................................................2
4. DEVICE LIST & INSTALLATION....................................... 4
5. WEB PAGE SETTING........................................................... 6
5.1 System Parameter Setting............................................... 6
5.1.1 PC Time ................................................................. 6
5.1.2 System Setup ......................................................... 6
5.1.3 Card Setup .............................................................7
5.2 E1 PRI Setting ................................................................ 8
5.4 Network Setting..............................................................9
5.5 Account Setting............................................................. 10
5.6 CDR.............................................................................. 10
5.7 Online Monitoring ........................................................ 11
5.8 Log PRI Data ................................................................ 11
-
8/2/2019 SCG 60 Manual
3/14
SCG-60 User Manual
-1-
1.Introduction
GSM E1 Channel Bank(SCG-60) is the newest product after our Digital Mobile
Trunk(DMT). Each SCG-60 system consists 2 sets of Channel Bank. Channel Bank
connects to E1 PRI of Exchange or VoIP Trunk Gateway. The 30 PRI channels are
individually connected to 30 ports of GSM channel, and is a perfect transform device
between digital circuits to GSM channels. SCG-60 can provide Call Detail Record
(CDR) for traffic and billing management.
SCG-60 system can be configured and queried through web page by remote
console, which includes the network IP setting, password validation, call detail record,
and monitoring the channel status, etc.
-
8/2/2019 SCG 60 Manual
4/14
SCG-60 User Manual
-2-
2.System Configuration Diagram
SCG-60 consists 2 sets of Channel Bank. One set of Channel Bank connects to
one ISDN E1 PRI. When an incoming call received from the E1 channel, the MCU
will retrieve the called number and dial out the number from the corresponding GSM
channel. These two channels are connected so that this call has been conducted into
the GSM channel. The incoming call from the GSM channel will be treated in thesame way.
3.Mechanism diagram
-
8/2/2019 SCG 60 Manual
5/14
SCG-60 User Manual
-3-
SCG-60 dimensions: 19" standard cabinet, Height 4U, Depth 42CM.
It consists 2 sets of channel bank, one set of channel bank consists 5
x GSM6 and 1 x Trunk MCU.
GSM : provides 6 GSM ports per card. There are 6 LEDs on the
front plate, indicating the status of each port.
[ SCG-60 spec in the GSM6 ]
Providing 6 channels GSM per card.
LED GSM status display.
GSM/GPRSPhase 2+ Compliance
GSM Frequency bands: Tri Band EGSM 900, DCS 1800and PCS 1900MHZ
Power Consumption
Speech Mode230mA(min)260mA(max)
Standby Mode
-
8/2/2019 SCG 60 Manual
6/14
SCG-60 User Manual
-4-
[ Power Card ]
Input Voltage: AC90-135V, AC180-264V, 50Hz~60Hz.
Input Current: 8A for 115VAC, 5A for 230VAC.
Type: Switching.
Output:+3.3V_28A,+5V_30A,+12V_15A,-5V_0.5A,-12V_1A,+5VSB_2A.
Total Power: 300W.
Power Panel.
4. Device List & Installation
4.1. Device List
ATX Power card 110V(or220V)*1
GSM6 card*10
Trunk/MCU Card*2Antenna box*2
4.2. Installation
(1)Check if all the parts are included.
(2)Inside the GSM6 card, there are 6 GSM SIM card holders. Put SIM cards in the
corresponding position.
-
8/2/2019 SCG 60 Manual
7/14
SCG-60 User Manual
-5-
(3)Lock up all the antennas in the front of the GSM6 card. (There are 30
antennas in the antenna box for 5 pieces of GSM6 card)
(4)Connect the E1/PRI cable for the Trunk/MCU card.
(5)Connect the network cable for the Trunk/MCU card. The default IP address is
192.168.0.107. You can change the IP address afterwards.
Total 30 antennas
3 2 1
6 5 4
3
2
14
5
6
12
-
8/2/2019 SCG 60 Manual
8/14
SCG-60 User Manual
-6-
(6)Switch the power on.
5. Web Page Setting
The supervisor can setup the system parameters or view the CDR by remotely
login in the web page of the SCG-60. The default IP address is 192.168.0.107. After
the supervisor connect to the web page, he/she can change the IP address in Network
setting page(see 4.4 Network setting).If you purchase two sets E1, you have to modify one of the IP address to avoid
conflict between these two MCU cards.
5.1 System Parameter Setting
5.1.1 PC Time
Synchronize the time of SCG-60 with the PC
5.1.2 System Setup
(1) PRI ModeSetup the PRI mode for User(TE)/Network(NT) mode
E1
LAN
-
8/2/2019 SCG 60 Manual
9/14
SCG-60 User Manual
-7-
(2) Hide the Caller ID : Hide or show the caller ID when dial out from the GSM
module
(3) Option for line is not ready : setup the behavior when the corresponding outgoing
channel is not ready. The option can be 1) Automatically hang up the call by the
system, or 2) Wait till the incoming call hangs up.
5.1.3 Card Setup
GSM Card1~GSM Card5 disable or enable.
-
8/2/2019 SCG 60 Manual
10/14
SCG-60 User Manual
-8-
5.2 E1 PRI Setting
E1 PRI setting : Set up the called number for each of the 30 channels. Also, we can
enable/disable the usage of each channel.
-
8/2/2019 SCG 60 Manual
11/14
SCG-60 User Manual
-9-
5.3 GSM Channel Setting
GSM Outbound :
GSM Setup : Setup the mobile number for each GSM channel
5.4 Network Setting
Setup the IP address and associated network information for theSCG-60
-
8/2/2019 SCG 60 Manual
12/14
SCG-60 User Manual
-10-
5.5 Account Setting
Setup the user name and password
5.6 CDR
View the call detail record
SCIDSIM card ID
GSMNumGSM Number
-
8/2/2019 SCG 60 Manual
13/14
SCG-60 User Manual
-11-
5.7 Online Monitoring
GSM System : Show the network usage of the GSM channel
Signal : Signal strength
Status : Indicates whether this call is from trunk to GSM, or from GSM to trunk
Trunk Status : Show the line status, e.g. Ring, HangUp
5.8 Log PRI Data
Log the activities of the PRI connection
Total 30 channels
-
8/2/2019 SCG 60 Manual
14/14
Technology Co., Ltd.
Tel: 886-2-32341496 - 97
Fax: 886-2-32341393
E-mail: [email protected] Website: www.suncomm.com.tw