SBC Introduction Called as Alicanto and new symm naming convention is Vmax

10K. 4 engine max system configuration i.e. 8 directors. Two flavors available , Fab less and fabric. Single engine is called fabless as we it does not require MIBE. Multi engine is called fabric system i.e. online up gradation of

engines by using MIBE( second engine always have MIBE and other will be connected to it).

Engine and drives present on the same bay and can have daisy chained bay .

Up to 64 DAEs ( 16 per engine). 6 DIMMs present for each engine.

Page 3: SBC ( Symmetrix Business Class)

SBC Engine layout Argonaut engine: Both the directors are next to

each other not as one on the top of other (Vmax 1).

Each engine has two power supplies and a management module.

Each director has I/O modules ( Front and back end).

Each director has management module.

Front view

Director X Director Y

4 Power Supplies with integrated Fans

Rear View

I/O Modules I/O Modules

Director Y Director X

Management Module (Akula)

Management Module (Akula)

Page 4: SBC ( Symmetrix Business Class)

SBC : 1 engine , 60 drive config

Engine 1: Dir 1 & 2

SPS Modules for 1st 4 Vault DAE

SPS Modules Engine

No support for CKD DAE and directors present on the same bayDAE will be added in number of4.First 4 DAE are vault DAE.No battery support for non-vault DAE(immediate vault on power loss).Up to 16DAE and each DAE supports 15 drives so total of 240 drives.The diagram shows 1 Engine 60 drive configuration.

Page 5: SBC ( Symmetrix Business Class)

SBC : Adding DAEsDAE

DAE

DAE

DAE

Vault DAE

Vault DAE

Empty

Argonaut

Cable Manager

SERVER

UPS

2.2 KW SPS

DAE

DAE

Vault DAE

Vault DAE

2.2 KW SPS

First chunk of DAE

First chunk of DAE

Second chunk of DAE

Second chunk of DAE

Empty

DAE

DAE

DAE

DAE

DAE

DAE

Empty

Third chunk of DAE

Third chunk of DAE

Fourth chunk of DAE

Page 6: SBC ( Symmetrix Business Class)

SBC : MIBE

MIBE

Page 7: SBC ( Symmetrix Business Class)

SBC : 4 bay max config(960 drive)

Bolted together using Copper Cables

10 Meter Dispersion using Optical Cables

Page 8: SBC ( Symmetrix Business Class)

SBC : Engine components

Rear View

Management Module B

Spar

tan

or G

lact

an

A0, A

1,B0

,B1

BEAuro

raFa

bric

A

Fabr

ic

B

Spar

tan

or G

lact

an

C0, C

1,D0

,D1

BE

Spar

tan

or G

lact

an

A0, A

1,B0

,B1

BEAuro

raFa

bric

A

Fabr

ic

B

Spar

tan

or G

lact

an

C0, C

1,D0

,D1

BE

Management Module A

Director 2

I/OModule 0

I/OModule 2

I/OModule 3

I/OModule 4

I/OModule 1

I/OModule 0

I/OModule 2

I/OModule 3I/O

Module 4I/OModule 1

I/O Module 0 SIB ( system interface board) . I/O Module 1 & I/O Module 2 Backend slices , 1 controls A&B ,2 controls C&D. I/O Module 3 & I/O Module 4 Front end slices , 3 controls E&F , 4 controls G & H.

Director 1

Page 9: SBC ( Symmetrix Business Class)

SBC : Front end configs

IO MODULE3

IO MODULE4

IO MODULE3

IO MODULE4

SE or FA or FE or combination of these emulations.

SE or FA or FE or combination of these emulations.

FE is FCoE . Fibre Channel over Ethernet (FCoE): Fibre Channel over Ethernet, FCoE is a proposed standard for using the Fibre Channel protocol over Ethernet networks. FCoE enables SAN traffic to be natively transported over Ethernet networks, while protecting and extending the investment that enterprises have made in storage networks.

Page 10: SBC ( Symmetrix Business Class)

SBC : Front end configs(continued..) All front ends are FA.

Glac

ier

E0

E1

F0

F1

Glac

ier

G0

G1

H0

H1

Glac

ier

E0

E1

F0

F1

Glac

ier

G0

G1

H0

H1

All front ends are SE.

Qui

ckSa

nd

E0F0

Qui

ckSa

ndG0

H0

Qui

ckSa

nd

E0F0

Qui

ckSa

ndG0

H0

EVEN DIR

ODD DIR

EVEN DIR

ODD DIR

Page 11: SBC ( Symmetrix Business Class)

SBC : Front end configs(continued..) All front ends are FE.

Mixed SE and FE.

Heat

Wav

e

E0F0

EVEN DIR

ODD DIR

EVEN DIR

ODD DIR

Heat

wav

e

G0

H0

Heat

wav

e

E0

F0

Heat

wav

e

G0

H0

Heat

wav

e

E0

F0

Heat

wav

e

G0

H0

Heat

Wav

e

E0F0

Heat

wav

e

G0

H0

Page 12: SBC ( Symmetrix Business Class)

SBC : Front end configs(continued..) Mixed SE and FA.

Mixed FA and FE.

EVEN DIR

ODD DIR

EVEN DIR

ODD DIR

Glac

ier

E

0

E1

F0

F1

Qui

ckSa

ndG0

H0

Glac

ier

E

0

E1

F0

F1

Qui

ckSa

ndG0

H0

Glac

ier

E0

E1

F0

F1

Heat

wav

e

G0

H0

Glac

ier

E0

E1

F0

F1

Heat

wav

e

G0

H0

Page 13: SBC ( Symmetrix Business Class)

Argonaut director

DIMMs

Argonaut CPU

Page 14: SBC ( Symmetrix Business Class)

Diff between V1 and SBC 6 DIMMs only (8 in V1) Single phase power only. Same rules as Drive Bay Dispersion in V-Max V1. No mainframe support. No battery backup for non-vault DAE.