OWNER’S MANUAL ENGLISH Remote Control .......................................................................................................3 - 5 Safety Regulations and Maintenance ........................................................................... 6 Unit Operation .........................................................................................................7 - 8 Wiring Diagrams ........................................................................................................... 9 Operation Tips ............................................................................................................ 10 Notes ...................................................................................................................... 11 Pag. 035 AK 075 AK Saunier Duval Clima, S.A. www.saunier-duval.co.uk 2003

Transcript of Saunier Duval Clima, S.A. · 2018. 8. 8. · Remote Control ... Saunier Duval Clima, S.A. 2003. 3...

  • OWNER’S MANUAL

    EN

    GLI

    SH

    Remote Control .......................................................................................................3 - 5Safety Regulations and Maintenance...........................................................................6Unit Operation .........................................................................................................7 - 8Wiring Diagrams ...........................................................................................................9Operation Tips ............................................................................................................10Notes ...................................................................................................................... 11

    Pag.

    035 AK075 AK

    Saunier Duval Clima, S.A.

    www.saunier-duval.co.uk2003

  • 3

    EN

    GLI

    SH

    Thank you very much for choosing our air conditioner!Please read this Owner’s Manual carefully before using your air conditioner.

    Notice:

    1. The outline of the air conditioner on the manual cover is only a sketch.2. Before you operate your air conditioner, please read the Important Safety Information Chapter first to avoid the air

    conditioner damage or any other accident caused by your mishandling.3. All pictures are only sketches. If there is any difference between the pictures shown in this manual and the actual

    shape of the air conditioner you purchased, the actual shape will prevail.4. This air conditioner must be installed by a specialist. Otherwise it will not be covered by any warranty.

  • 3

    EN

    GLI

    SH

    1.- REMOTE CONTROL

    1.1. REMOTE CONTROL

    TimerON / OFF

    Clock

    Hour and Minutes

    Fan speed: AUTO-LOW-MED-HIGH

    SLEEPSWING

    Set Temp.

    Mode: FAN-COOL-HEAT

    Transmission sourceUsed for sending control signal to the air conditioning unit.

    ON/OFFPress button to set timer mode.

    HOUR buttonPress button to increase the time 1 hour a step (24 hours).MINUTE buttonPress button to increase the time 10 minutes a step in timer mode and 1 minute a step in real time clock.

    WARM buttonPress button to increase temperature (max. 30ºC).COOL buttonPress button to decrease temperature (min. 15ºC).

    SWING buttonAir distributor in all modes.

    SLEEP buttonSLEEP mode will automatically adjust tem-perature and save energy when you are sleeping.

    CLOCKTo set time press HOUR and MINUTE buttons simul-taneusly. To confirm press TIMER.

    LCD DISPLAY

    FAN buttonPress button to select (LOW-MED-HIGH-AUTO).

    MODE buttonPress button to select: HEAT, COOL y FAN.

    ON/OFF buttonPressing this button will turn the air conditioning unit ON or OFF.

  • 4

    EN

    GLI

    SH

    5

    EN

    GLI

    SH

    1.- REMOTE CONTROL

    1.2. ON / OFF BUTTON

    1.3. MODE BUTTON

    - Every press of this button will turn the air condi-tioning unit ON or OFF.

    - When pressed ON, the system will operate and display all characters on the LCD.

    - When pressed OFF, the characters disappear. Clock displays normally.

    - Every button press will change the operation mode and corresponding sign on LCD display in sequence as follows.

    COOL- FAN - HEAT

    - Each mode has a memory which records the previous operating fan speed and set tempe-taure.

    1.4. FAN BUTTON

    - Every button press will change the fan speed and corresponding sign on LCD display in sequence as follows.

    AUTO - LOW - MED - HIGH

    - There is no auto fan speed in fan mode.

    1.5. SWING BUTTON

    - Press this button to turn on swing mode. LCD displays the corresponding sign. Press it again to stop the louver in the prefered air distribution location.

    1.6. SLEEP BUTTON

    - Press this button to turn on sleep function. LCD displays the correponding sign. Press it again to turn off and clear the sign.

    1.7. WARM BUTTON (TEMP UP)

    - Only available in cool or heat mode. Each press of this button will increase set temperature 1ºC and LCD will display the value.

    - The maximum setting temperature is 30ºC.- This button is disabled in fan mode.

    1.8. COOL BUTTON (TEMP DOWN)

    - Only available in cool or heat mode. Each press of this button will decrease set temperature 1ºC and LCD will display the value.

    - The maximum setting temperature is 15ºC.- This button is disabled in fan mode.

    1.9. TIMER BUTTON

    TIMER ON- Can only be set when system is off. After pres-

    sing timer button, LCD display is changed from clock to timer and will display the last setting. Please set time on by pressing hour and min buttons. When the set number elapses, the system will start and the LCD will display the set memory for fan speed, mode and set tempera-ture. The clock displays normally.

    TIMER OFF- Can only be set when system is on. After pres-

    sing timer button, LCD display is changed from clock to timer and will display the last setting. Please set timer off by pressing hour and min buttons. When the set number elapses, the system will stop except for the clock which dis-plays normally.

    - When timer mode is activated. The colon mark between hour and minute display will not blink.

    - Setting timer for less than hour or changing of on/off state will cancel timer mode.

    1.10. HOUR BUTTON

    - This button is for timer mode and clock setting.- Each press of this button increases the clock or

    timer by 1 hour.

  • 4

    EN

    GLI

    SH

    5

    EN

    GLI

    SH

    1.- REMOTE CONTROL

    1.11. MIN BUTTON

    - This button is for timer mode and clock setting.- Each press of this button increases the timer by

    10 minutes and the clock by 1 minute.

    1.12. BATTERY COMPARTMENT

    - When batteries (AAA ó LR03) are getting weak, please insert the new ones carefully as shown below. Remote controller will self-test and dis-play all the characters on the LCD. After one second, all characters will disappear remote controller is idle and clock digits blink 00:00.

    - Please set the clock after changing the batteries by pressing hour & min buttons. Confirm by pres-sing timer button to check if the clock is correct.

    - The retired batteries of the controls must be deposited in containers to recycle.

    - The IR signal can be received at an effective distance of 8 meters, at an angle of 30º or by reflection.

    - Cassette installations without valve are not recommended, as the drain pump/float switch will be in conti-nuous operation. Valve to be supplied and installed on site by others.

  • 6

    EN

    GLI

    SH

    7

    EN

    GLI

    SH

    2.- SAFETY REGULATIONS AND MAINTENANCE

    2.1. PRELIMINARY CHECKS BEFORE START-UP

    - The unit should not be started up until the system piping has been cleaned and allthe air has been purged.

    - Check condensate drinpipe slope.- Make sure that air filter is clean and properly installed.- Ensure that voltage and current values correspond with the unit nameplate values; check electrical con-

    nections.- Verify that air outlets are not closed.

    2.2. MAINTENANCE

    - Before performing any service or maintenance operations, turn off the main power switch.- The air filter is made of acrylic fiber and is washable in water. To remove filter simply open the intake grille

    by releasing the two catches.- Check the filter periodically and before the operating season; clean or replace as necessary.

    2.3. PROLONGED UNIT SHUT-DOWN

    - Prior to restarting the unit: Clean or replace the air fliters. Check and remove any obstruction from the external auxiliary pan and the internal.

    2.4. EXTRA MAINTENANCE

    - The electrical panel is easily accessible by removing the cover panel.- The inspection or replacement of internal components such as; heat exchanger coil, condensate dis-

    charge pump, safety micro float, involves the removal of the condensate drain pan.- During the removal of the condensate drain pan protect the floor under the unit, with a plast sheet, from

    condensate water that could be spilled.- Remove fixing screws of the drain pan fixture and remove condensate drain pan with care.

    2.5. OPERATING LIMITS

    - Power supply: 230/1/50 (V/Ph/Hz)- Water circuit Minimum entering water temperature: +2ºC. Maximum entering water temperature: +80ºC. Water side maximum pressure: 1.400 kPa (142 m.c.a.).

  • 6

    EN

    GLI

    SH

    7

    EN

    GLI

    SH

    3.- UNIT OPERATION

    3.1. ABBREVIATION

    Ts: Setting Temperature. Tr: Room Temperature. Ti: Indoor Temperature Sensor. Aux: Auxillary Contact.

    3.2. COOL MODE

    - If Tr ≥ Ts, cool operation is activated. Motorized valve is turned on, Aux 2 is closed. Indoor fan runs at set speed.

    - If Tr ≤ Ts - 0,5ºC, cool operation is finished. Moto-rized valve is turned off, Aux 2 is opened.

    - Indoor fan runs at the set speed.- The range of Ts is 15º~30ºC.- Indoor fan speed can be adjusted for low,

    medium, high and auto. - Motorized valve will delay for 30 seconds before

    it is turned on or off.

    PROTECTION FOR INDOOR COIL PRIORITY SOFTWARE

    - If Ti ≤ 2ºC, motorized valve is turned off, Aux 2 is opened. Indoor fan keeps running at the set speed.

    3.3. FAN MODE

    - Indoor fan runs at the set speed while motori-zed valve is turned off . Aux 1 and Aux 2 are opened.

    - Indoor fan speed can be adjusted for low, medium and high.

    3.4. HEAT MODE

    - If Tr ≤ Ts, heat operation is activated, motorized valve is turned on, Aux 1 is closed. Indoor fan runs at the set speed.

    - If Tr ≥ Ts + 0,5ºC, heat operation is finished, motorized valve and indoor fan are turned off. Aux 1 is opened.

    - The range of Ts is 15º~30ºC.- Indoor fan speed can be adjusted for low,

    medium, high and auto.

    - Motorized valve will delay for 30 seconds before it is turned on or off.

    PROTECTION FOR INDOOR COIL PRIORITY SOFTWARE

    - If Ti ≤ 38ºC, motorized valve is turned on, indoor fan is turnde off and Aux 1 is closed.

    - If Ti ≥ 38ºC, motorized valve is turned on, Aux 1 is closed. Indoor fan starts at the set speed.

    - If Ti ≥ 75ºC, motorized valve is turned off while Aux 1 is opened. Indoor fan keeps running at the set speed.

    3.5. TIMER

    - Timer off can only be set when the system is operating.

    - Timer on can only be set when the system is off.- The maximum set time is 24 hours.- Changing of on/off state will cancel timer mode.

    3.6. AUXILLARY CONTACTS

    3.6.1. Heat Mode (Aux 2)

    - Aux 2 is closed when motorized valve is on (in normal operation). Aux 2 is opened when moto-rized valve is off or protection of indoor coil is operating.

    3.6.2. Fan Mode (Aux 1 and Aux 2)

    - Aux 1 and Aux 2 are opened when indoor fan is on.

    3.6.3. Heat Mode (Aux 1)

    - Aux 1 is closed when motorized valve is on (in normal operation). Aux 1 is opened when moto-rized valve is off or protection of indoor coil is operating.

  • 8

    EN

    GLI

    SH

    9

    EN

    GLI

    SH

    3.- UNIT OPERATION

    3.7. SLEEP MODE

    - Sleep mode can only be set in cool and heat mode.

    - In cool mode, after sleep mode is set, Ts will increase 1ºC each hour for 2 hours.

    - In heat mode, after sleep mode is set, Ts will decrease 1ºC each hour for 2 hours.

    - Changing of operation mode will cancel sleep mode.

    3.8. AUTO FAN SLEEP

    - If Tr-Ts

  • 8

    EN

    GLI

    SH

    9

    EN

    GLI

    SH

    4.- WIRING DIAGRAMS

    035 AK UNITS

    075 AK UNITS

  • 10

    EN

    GLI

    SH

    11

    EN

    GLI

    SH

    - Set suitable indoor temp. Too hot and too cold do no good to your health. Set a temp you feel comfortable.- Use TIMER properly. Do not expose yourself to direct cold-airflow for too long when sleeping in summer.- Keep doors and windows shut tightly. Avoid wasting of energy to raise cooling or heating effect.- Adjust airflow direction properly. Usually set airflow upwards at cooling and downwards at heating to get uniform room temperature.- Ventilate open. Ventilate the room for 1 to 2 munutes every 1 hour for health’s sake specially an oil bumer is used inside.- Clean the air filter regularly. Dirty filter will decrease efficiency, generate noise and waste electricity. Better to clean it every two

    weeks.

    5.1. FOR A SUITABLE OPERATION