San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for...

158
Prepared for: City of San Diego Planning Department 1010 Second Avenue, Suite 1200 San Diego, CA 92101 San Ysidro Community Plan Update and San Ysidro Historic Village Specific Plan Air Quality Technical Report May 2016 Prepared by: HELIX Environmental Planning, Inc. 7578 El Cajon Boulevard La Mesa, CA 91942

Transcript of San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for...

Page 1: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Prepared for:

City of San DiegoPlanning Department1010 Second Avenue, Suite 1200

San Diego, CA 92101

San Ysidro Community Plan Updateand San Ysidro Historic Village Specific Plan

Air Quality Technical Report

May 2016

Prepared by:

HELIX Environmental Planning, Inc.7578 El Cajon Boulevard

La Mesa, CA 91942

Page 2: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report

for the

San Ysidro Community Plan Update and

San Ysidro Historic Village Specific Plan

Prepared for:

City of San Diego Planning Department

1010 Second Avenue, Suite 1200 San Diego, CA 92101

Prepared by:

HELIX Environmental Planning, Inc. 7578 El Cajon Boulevard

La Mesa, CA 91942

May 2016

Page 3: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

i

San Ysidro Community Plan Update and San Ysidro Historic Village Specific Plan

Air Quality Technical Report

TABLE OF CONTENTS

Section Page

EXECUTIVE SUMMARY ...................................................................................................... ES-1

1.0 INTRODUCTION .............................................................................................................. 1

1.1 Purpose of The Report ............................................................................................... 1 1.2 Project Description..................................................................................................... 1

1.2.1 San Ysidro Community Plan Update ............................................................. 1 1.2.2 San Ysidro Historic Village Specific Plan ..................................................... 2

1.3 Regulatory Requirements and Best Management Practices ...................................... 3 1.3.1 Regulatory Requirements............................................................................... 3 1.3.2 Construction Best Management Practices ..................................................... 4

2.0 EXISTING CONDITIONS ................................................................................................. 5

2.1 Climate and Meteorology .......................................................................................... 5 2.2 Air Pollutants of Concern .......................................................................................... 5

2.2.1 Criteria Air Pollutants .................................................................................... 5 2.2.2 Toxic Air Contaminants ................................................................................. 7

2.3 Regulatory Setting ..................................................................................................... 7 2.4 Background Air Quality ........................................................................................... 10

3.0 SIGNIFICANCE CRITERIA AND ANALYSIS METHODOLOGIES .......................... 12

3.1 Significance Criteria ................................................................................................ 12 3.2 Methodology ............................................................................................................ 13

4.0 PROJECT IMPACTS ....................................................................................................... 14

4.1 SYCPU ..................................................................................................................... 14 4.1.1 Conformance to the Regional Air Quality Strategy ..................................... 14 4.1.2 Conformance to Federal and State Ambient Air Quality Standards ............ 16 4.1.3 Cumulatively Considerable Net Increase of Criteria Pollutants .................. 20 4.1.4 Impacts to Sensitive Receptors .................................................................... 20 4.1.5 Odor Impacts ................................................................................................ 22

4.2 SYHVSP .................................................................................................................. 23 4.2.1 Conformance to the Regional Air Quality Strategy ..................................... 23 4.2.2 Conformance to Federal and State Ambient Air Quality Standards ............ 23 4.2.3 Cumulatively Considerable Net Increase of Criteria Pollutants .................. 23 4.2.4 Impacts to Sensitive Receptors .................................................................... 23 4.2.5 Odor Impacts ................................................................................................ 24

Page 4: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ii

TABLE OF CONTENTS (cont.) Section Page 5.0 SUMMARY OF IMPACTS AND RECOMMENDED MEASURES ............................. 24

5.1 Conformance to the Regional Air Quality Strategy ................................................. 24 5.2 Conformance to Federal and State Ambient Air Quality Standards ........................ 24 5.3 Cumulatively Considerable Net Increase of Criteria Pollutants .............................. 26 5.4 Impacts to Sensitive Receptors ................................................................................ 27

5.4.1 Carbon Monoxide Hot Spots ....................................................................... 27 5.4.2 Toxic Air Contaminants and Diesel Particulate Matter ............................... 27

5.5 Odors ........................................................................................................................ 27

6.0 REFERENCES ................................................................................................................. 28

7.0 LIST OF PREPARERS..................................................................................................... 29

LIST OF APPENDICES A CalEEMod Emission Calculations

LIST OF FIGURES No. Title Follows Page 1 Site Vicinity Map .................................................................................................................2 2 Project Vicinity Map (Aerial Photograph) ...........................................................................2 3 Land Use Plan ......................................................................................................................2

LIST OF TABLES No. Title Page 1 California and National Ambient Air Quality Standards .....................................................9 2 Federal and State Air Quality Designation ........................................................................10 3 Air Quality Monitoring Data .............................................................................................11 4 Screening-level Thresholds for Air Quality Impact Analysis ............................................13 5 Existing and Future SYCPU Land Uses ............................................................................17 6 Average Daily Operational Emissions ...............................................................................20 7 CARB Land Use Siting Recommendations .......................................................................22

Page 5: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

iii

LIST OF ACRONYMS µg/m3 micrograms per cubic meter AB Assembly Bill AQIA Air Quality Impact Assessment BAU business as usual BMPs best management practices CAA Clean Air Act (Federal) CAAQS California Ambient Air Quality Standard CalEEMod California Emission Estimator Model CalEPA California Environmental Protection Agency CALGreen California Green Building Standards Code CARB California Air Resources Board CCAA California Clean Air Act CEC California Energy Commission CEQA California Environmental Quality Act CEUS California Commercial End Use Survey City City of San Diego CO carbon monoxide County County of San Diego DPM diesel particulate matter ºF Fahrenheit (degrees) g/L grams per liter GHG greenhouse gas H2S hydrogen sulfide IEM Iowa Environmental Mesonet I- Interstate LCFS Low Carbon Fuel Standard LOS level of service mph miles per hour NAAQS National Ambient Air Quality Standard NO nitrogen oxide NOX oxides of nitrogen NO2 nitrogen dioxide

Page 6: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

iv

LIST OF ACRONYMS (cont.)

O3 Ozone Pb lead PM2.5 fine particulate matter (particulate matter with an aerodynamic diameter of

2.5 microns or less) PM10 respirable particulate matter (particulate matter with an aerodynamic

diameter of 10 microns or less) ppm parts per million PVC polyvinyl chloride RAQS Regional Air Quality Strategy RASS Residential Appliance Saturation Survey ROG reactive organic gas SANDAG San Diego Association of Governments SCAQMD South Coast Air Quality Management District SDAB San Diego Air Basin SDAPCD San Diego County Air Pollution Control District SDG&E San Diego Gas & Electric SIP State Implementation Plan SOX oxides of sulfur SO2 sulfur dioxide SYCPU San Ysidro Community Plan Update SYHVSP San Ysidro Historic Village Specific Plan T-BACT Toxics Best Available Control Technology TAC Toxic Air Contaminant USEPA United States Environmental Protection Agency VOC volatile organic compound WRCC Western Regional Climate Center

Page 7: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 ES-1

EXECUTIVE SUMMARY

This report evaluates the potential air quality impacts associated with the San Ysidro Community Plan Update (SYCPU or “Project”) and the San Ysidro Historic Village Specific Plan (SYHVSP) which is included within the SYCPU area. An assessment was made to estimate the criteria pollutant emissions that would be emitted as a result of full development of the SYCPU.

As discussed in Section 4.1.2, the proposed Project would involve changes in land use designations from the adopted community plan that would change the buildout condition of the SYCPU and SYHVSP project areas. Therefore, the land uses proposed under the SYHVSP and SYCPU would not be consistent with the adopted General Plan upon which the Regional Air Quality Strategy (RAQS) and State Implementation Plan (SIP) were based. However, as discussed in the traffic impact analysis prepared for the SYCPU, the adopted community plan land use designations would be expected to generate more average daily trips (ADT) than the uses proposed under the SYCPU (472,023 ADT compared to 407,233 ADT) (Kimley-Horn 2015). Thus, while the proposed land uses under the SYCPU were not included in the emissions assumptions contained within the RAQS, the vehicle trips from the SYCPU are less than those anticipated from the adopted community plan. Thus, even though it was not assumed in the RAQS, the proposed SYCPU is therefore generally consistent with the intent of the RAQS, and would not impede the goals contained within the RAQS.

The Project would result in emissions of air pollutants during both the construction phase and operational phase of future development associated with the SYCPU and SYHVSP. Implementation of Mitigation Measures AQ-1 and AQ-2, discussed below, would reduce construction emissions associated with new development within the SYCPU and SYHVSP. Operational emissions would be associated with vehicle trips generated by the SYCPU and SYHVSP development, along with area sources such as energy use and landscaping. Based on the evaluation of air emissions, the emissions would exceed the screening-level thresholds for volatile organic compounds (VOCs), carbon monoxide (CO), respirable particulate matter with an aerodynamic diameter of 10 microns or less (PM10), and fine particulate matter with an aerodynamic diameter of 2.5 microns or less (PM2.5), and would result in a significant impact for air quality. A wide range of current regulatory codes, project design features, and other measures would be incorporated into future development including energy-efficiency features that would meet 2013 California Title 24 Energy Efficiency Standards. Implementation of Mitigation Measures AQ-4 and AQ-5, discussed below, would reduce operational emissions. While implementation of Mitigation Measures AQ-1 through AQ-5 would reduce construction and operations emissions, the ability of future development to successfully implement the actions required to fully meet these mitigation measures at the project level cannot be guaranteed at this time. Thus, air pollutant impacts from construction and operation under the proposed SYCPU and SYHVSP are considered significant and unavoidable at the program-level.

If air emissions from a specific facility include toxic substances or would exceed identified limits, the facility would be required by the San Diego Air Pollution Control District (SDAPCD) to provide information regarding emission inventories and health risk assessments. If adverse health impacts exceeding public notification levels are identified, the facility would provide public notice, and if the facility poses a potentially significant public health risk, the facility would be required to submit a risk reduction audit and plan to demonstrate how the facility

Page 8: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 ES-2

would reduce health risks. Thus, with this regulatory framework, at the program level, impacts associated with stationary sources in the SYCPU area would be less than significant.

Future traffic generated by the SYCPU and SYHVSP could result in the degradation of roadway intersections such that emissions of CO would exceed state or federal standards that would result in a CO hot spot. While implementation of Mitigation Measures AQ-3 and AQ-4 would reduce construction and operations CO emissions, the ability of future development to successfully implement the actions required to fully meet CO hot spots cannot be guaranteed at this time. Thus, CO hotspot impacts from construction and operation under the proposed SYCPU and SYHVSP are considered significant and unavoidable at the program level.

High traffic volumes on Interstate (I-) 5 and State Route (SR-) 905 could generate diesel particulate matter (DPM) levels that would exceed allowable health standards for sensitive receptors. The California Air Resources Board (CARB) recommends that sensitive receptors (e.g. residential dwellings) be located at least 500 feet from major roadways. Thus, new uses within 500 feet of I-5 and SR-905 could be significantly impacted by DPM within both the SYCPU and SYHVSP areas. While implementation of Mitigation Measure AQ-6, which requires a health risk assessment to demonstrate that sensitive receptors located within 500 feet of these freeways would not be adversely affected by DPM, the ability of future development to successfully implement the actions required to fully meet the DPM standard cannot be guaranteed at this time. Thus, DPM impacts on future development under the proposed SYCPU and SYHVSP are considered significant and unavoidable at the program level.

An evaluation of potential odors from construction activities and land use operation indicated that the SYCPU and SYHVSP would not expose substantial numbers of people to objectionable odors.

Page 9: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1

1.0 INTRODUCTION

1.1 PURPOSE OF THE REPORT

This report analyzes potential air quality impacts associated with the San Ysidro Community Plan Update (SYCPU or “Project”) and the San Ysidro Historic Village Specific Plan (SYHVSP), which includes an evaluation of existing conditions in the Project vicinity, and an evaluation of construction and operational impacts. The analysis of impacts and report is prepared in accordance with the City of San Diego’s (City) California Environmental Quality Act Significance Determination Thresholds (City 2011).

1.2 PROJECT DESCRIPTION

The proposed Project consists of two components: (1) the SYCPU, and (2) the SYHVSP.

1.2.1 San Ysidro Community Plan Update

The SYCPU is a comprehensive update to the current community plan, which was adopted in 1990. The San Ysidro Community Plan covers a total of 1,863 acres within the southern tip of the City of San Diego, adjacent to Otay Mesa-Nestor, Otay Mesa, the Tijuana River Valley, and the international border with Mexico (see Figure 1, Site Vicinity Map, and Figure 2, Project Vicinity Map [Aerial Photograph], respectively).

The SYCPU includes the following eight individual elements intended to guide development: Land Use; Mobility; Urban Design; Economic Prosperity; Public Facilities, Services & Safety; Recreation; Conservation; and Historic Preservation. Each element would be updated to bring the community plan into conformance with the City’s General Plan as well as embrace current urban planning and sustainability concepts.

The Land Use Element is designed to guide future development within the community. It establishes land use designations for each portion of the community (see Figure 3, Land Use Plan). The majority of the plan area (41 percent) would be designated for residential uses. Commercial uses would comprise 18 percent. Industrial development would comprise 2 percent of the community plan area. A total of 11 percent of the plan area would be designated for institutional uses. Parks and Open Space would cover 5 and 13 percent of the area, respectively. The balance would be occupied by transportation facilities.

The Mobility Element is intended to improve mobility throughout the community through the development of a balanced multi-modal transportation network. The Element recommends future improvements to specific roadway segments ranging from restriping to new roadway connections. The Element also contains a number of policies designed to encourage the use of public transit including promoting pedestrian movement in the vicinity of transit and by enhancing existing bus and trolley stops.

The Urban Design Element establishes goals and policies that enhance the urban fabric of San Ysidro while retaining the historic elements that contribute to the overall character of the community.

Page 10: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 2

The Economic Prosperity Element envisions a strategic approach that is focused on increasing opportunities for densification of residential and commercial development in selected parts of the community, while protecting the existing strong neighborhoods through enhancement of neighborhood villages.

The Public Facilities, Services & Safety Element identifies existing facilities and services, and addresses the capacity and needs for future services including potential sites and desired characteristics for future facilities.

The Recreation Element is intended to ensure that the recreational needs of the community are met. The Element establishes goals and policies for population-based parks and recreation facilities within the community. In addition, the Element establishes goals and policies related to open space and resource-based parks.

The Conservation Element contains policies designed to meet the City’s sustainable development goals in areas that have been identified as suitable for development. The Conservation Element also addresses open space and habitat protection.

The Historic Preservation Element contains specific recommendations to address the history and cultural resources, unique to San Ysidro, in order to encourage protection and appreciation of these resources.

1.2.2 San Ysidro Historic Village Specific Plan

The SYHVSP, and identified on Figure 3, is a comprehensive planning document that will implement the vision for the SYCPU for this Specific Plan Area. The SYHVSP covers approximately 112 acres, and is bounded by Beyer Boulevard to the north, Interstate (I-) 5 to the south, I-805 to the east, and Smythe Avenue to the west.

The overall goal of the Specific Plan is to create an attractive, intensified urban environment with a mix of land uses surrounding the Beyer Trolley Station and along San Ysidro Boulevard, while preserving the low-scale single- and multi-family character of the residential areas.

The Land Use Component of the Specific Plan includes guidelines intended to: (1) preserve the historic character of the area; (2) attract community-oriented development; (3) promote alternate forms of transportation (e.g., walking and biking); and (4) focus increased residential density on major transportation corridors and near transit. The Specific Plan Area includes the following five land use designations, as specified by the SYCPU: Low-Medium Density Residential, Medium Density Residential, Community Commercial (Residential Permitted), Institutional, and Park.

The Mobility Component of the Specific Plan sets forth a number of polices and guidelines to promote mobility including (1) install new, and widen existing, sidewalks; (2) improve lighting and landscaping along sidewalks; (3) improve street crossings, and (4) incorporate bikeway facilities on select roadways.

The Urban Design Component of the Specific Plan identifies policies intended to enhance public spaces, including parks, public plazas, and roadways. The Specific Plan encourages the

Page 11: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Tijuana RiverValley

MEXICOUNITED STATES

Community PlanBoundary

Ota y River

!"̂$

%&s(

AòMTS - BLUE LINE

Brown Field Airport

Aeropuerto de Tijuana

I:\PRO

JECT

S\S\SD

D\SD

D-20

_San

Ysidr

o\Map

\ENV\

AQ\Fi

g1_S

ite_V

icinit

y.mxd

DCM

-01 0

9/10/1

5 -RK

Figure 1SAN YSIDRO COMMUNITY PLAN UPDATE

Site Vicinity Map

0 6,000FeetN

Source: Esri, i-cubed, USDA, USGS, AEX, GeoEye, Getmapping, Aerogrid, IGN, IGP, and the GIS User

Page 12: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

San YsidroHistoric VillageSpecific Plan

MEXICOUNITED STATES

Tijuana River Valley

!"̂$

%&s(

AòBeyer Boulevard

Camino De La Plaza

Otay

MesaRoad

Picador Boulevard

Del Sol Boulevard

W San Ysidro Boulevard East Beyer Boulevard

Camino De La Plaza

27th

Stree

t

Beye

r Way

Denn

ery R

oad

Palm Avenue

Smyth

e Ave

nue

Dairy

Mart

Roa

d

MTS - BLUE LINE

I:\PRO

JECT

S\S\SD

D\SD

D-20

_San

Ysidr

o\Map

\ENV\

AQ\Fi

g2_P

roject

Locat

ion.m

xd S

DD-20

03/0

3/16 -

RK

Figure 2SAN YSIDRO COMMUNITY PLAN UPDATE

Project Vicinity Map (Aerial Photograph)

0 2,500FeetN

Community PlanBoundary

Page 13: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Land Use PlanSAN YSIDRO COMMUNITY PLAN UPDATE

Figure 3

I:\PR

OJE

CTS

\S\S

DD

\SD

D-2

0_Sa

nYsi

dro\

Map

\EN

V\A

Q\F

ig3_

Land

Use

.indd

S

DD

-20

02/

16/1

6 -R

K

Source: SYCPU 2016

!(T

!(T

!(T

M E X I C O

BEYER BL

CAMINO DE LA PLAZA

WIL

LOW

ST

CALLE PRIMERA

VIA DE SAN YSIDRO

BORDER VILLAGE DR

OTAY MESA

OTAY MESA-NESTOR

TIJUANA RIVER VALLEY

AAòH

!!"̂$

!!"̂$

%%&s(

BEYER BL

IRIS AV

CAM DE LA PLAZA

EAST BEYER BL

SM

YTH

E A

V

OTAY MESA RD

DA

IRY

MA

RT

RD

SR-905 WB

BIBLER DR

W

SAN YSIDRO BL

TIJUANA RIVER

0 950 1,900475Feet

LegendAreas of TransitionVillageName

Border Village

San Ysidro Historic Village

Future Hillsides Neighborhood Village

ResidentialLow Density Residential (5-10 du/nra)

Low-Medium Density Residential (10-15 du/nra)

Low-Moderate Density Residential (10-22 du/nra)

Medium Density Residential (15-30 du/nra)

Commercial, Employment, Retail and ServicesCommunity Commercial

Heavy Commercial

Community Commercial/Residential Permitted

Regional Commercial

Industrial Employment Industrial

Institutional and Public and Semi-Public FacilitiesInstitutional

Park, Open Space, and RecreationPark

Open Space

TransportationRight-of-Way

Base FeaturesCommunity Plan Boundary

Light Rail

!(T Trolley Stop

Future Road Connection Alignments o

SAN YSIDRO COMMUNITY PLAN UPDATE 2/4/2016

Page 14: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 3

creation of pocket parks and neighborhood plazas. Enhanced streetscape is encouraged including benches, bicycle parking, and improved landscaping and lighting. Bioswales and pervious pavement are encouraged to reduce stormwater runoff and pollutants. Signage improvements are recommended to increase transit usage, and facilitate movement within the community. Lastly, the inclusion of public art is encouraged.

The Infrastructure and Public Facilities Component of the Specific Plan establishes policies and describes improvements necessary for the upgrading and expansion of public facilities, including water, wastewater, solid waste, stormwater, natural gas, police and fire protection, schools, libraries, parks, and other public services. Water conservation measures are identified to help ensure a reliable water supply. Stormwater facilities are encouraged to convey runoff through the Specific Plan Area, and reduce water pollution. Adequate staffing and equipment are identified as important to assuring adequate police and fire protection. A new location for the community library in the Specific Plan Area is proposed. Mini and pocket park locations are identified in the Specific Plan area to enhance recreational opportunities within the Specific Plan Area as well as the overall Community Plan Area.

1.3 REGULATORY REQUIREMENTS AND BEST MANAGEMENT PRACTICES

1.3.1 Regulatory Requirements

Construction Measures

Future development pursuant to the proposed SYCPU and SYHVSP would incorporate best management practices (BMPs) during construction to reduce emissions of fugitive dust. SDAPCD Rule 55 ‒ Fugitive Dust Control states that no dust and/or dirt shall leave the property line. SDAPCD Rule 55 requires the following:

(1) Airborne Dust Beyond the Property Line: No person shall engage in construction or demolition activity subject to this rule in a manner that discharges visible dust emissions into the atmosphere beyond the property line for a period or periods aggregating more than 3 minutes in any 60-minute period.

(2) Track-Out/Carry-Out: Visible roadway dust as a result of active operations, spillage from transport trucks, erosion, or track-out/carry-out shall:

(i) be minimized by the use of any of the following or equally effective trackout/ carry-out and erosion control measures that apply to future development or operation:

(a) track-out grates or gravel beds at each egress point,

(b) wheel-washing at each egress during muddy conditions, soil binders, chemical soil stabilizers, geotextiles, mulching, or seeding; and for outbound transport trucks:

(c) using secured tarps or cargo covering, watering, or treating of transported material; and

Page 15: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 4

(ii) be removed at the conclusion of each work day when active operations cease, or every 24 hours for continuous operations. If a street sweeper is used to remove any track-out/carry-out, only PM10-efficient street sweepers certified to meet the most current South Coast Air Quality Management District (SCAQMD) Rule 1186 requirements shall be used. The use of blowers for removal of track-out/ carry out is prohibited under any circumstances.

Area Source Reductions

• Use of low-VOC coatings in accordance with, or exceeding, SDAPCD Rule 67

o Residential interior coatings are to be less than or equal to 50 grams of volatile organic compound (VOC) per liter (g/L)

o Residential exterior coatings are to be less than or equal to 100 g/L

o Non-residential interior/exterior coatings are to be less than or equal to 100 g/L

Energy Efficiencies

• Future development will be designed to meet 2013 Title 24 energy efficiency standards

1.3.2 Construction Best Management Practices

The control measures listed below are the BMPs that future development would incorporate for dust control:

• Contractor(s) will implement paving, chip sealing or chemical stabilization of internal roadways after completion of grading.

• Dirt storage piles will be stabilized by chemical binders, tarps, fencing or other erosion control.

• A 15-mile per hour (mph) speed limit will be enforced on unpaved surfaces.

• On dry days, dirt and debris spilled onto paved surfaces shall be swept up immediately to reduce resuspension of particulate matter caused by vehicle movement. Approach routes to construction sites shall be cleaned daily of construction-related dirt in dry weather.

• Haul trucks hauling dirt, sand, soil, or other loose materials will be covered or two feet of freeboard will be maintained.

• Disturbed areas shall be hydroseeded, landscaped, or developed as quickly as possible and as directed by the County of San Diego (County) and/or SDAPCD to reduce dust generation.

• Grading will be terminated if winds exceed 25 mph.

• Any blasting areas would be wetted down prior to initiating the blast.

Page 16: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 5

• In accordance with California Green Building Standards Code (CALGreen) criteria and state and local laws, at least 50 percent of on- site construction waste and ongoing operational waste would be diverted from landfills through reuse and recycling.

2.0 EXISTING CONDITIONS

2.1 CLIMATE AND METEOROLOGY

The climate in southern California, including the San Diego Air Basin (SDAB) in which the Project site is located in, is controlled largely by the strength and position of the subtropical high-pressure cell over the Pacific Ocean. Areas within 30 miles of the coast experience moderate temperatures and comfortable humidity. Precipitation is limited to a few storms during the winter season. The climate of the County is characterized by hot, dry summers, and mild, wet winters.

The predominant wind direction in the vicinity of Project site is from the west and the average wind speed is approximately five mph (Iowa Environmental Mesonet [IEM] 2015). The annual average maximum temperature in the Project area is approximately 69 degrees Fahrenheit (ºF), and the average annual minimum temperature is approximately 54ºF. Total precipitation in the Project area averages approximately 10 inches annually. Precipitation occurs mostly during the winter and relatively infrequently during the summer (Western Regional Climate Center [WRCC] 2015).

Due to its climate, the SDAB experiences frequent temperature inversions (temperature increases as altitude increases, which is the opposite of general patterns). Temperature inversions prevent air close to the ground from mixing with the air above it. As a result, air pollutants are trapped near the ground. During the summer, air quality problems are created due to the interaction between the ocean surface and the lower layer of the atmosphere, creating a moist marine layer. An upper layer of warm air mass forms over the cool marine layer, preventing air pollutants from dispersing upward. Additionally, hydrocarbons and nitrogen dioxide (NO2) react under strong sunlight, creating smog. Light, daytime winds, predominantly from the west, further aggravate the condition by driving the air pollutants inland, toward the foothills. During the fall and winter, air quality problems are created due to carbon monoxide (CO) and NO2 emissions. High NO2 levels usually occur during autumn or winter, on days with summer-like conditions.

2.2 AIR POLLUTANTS OF CONCERN

2.2.1 Criteria Air Pollutants

Federal and state laws regulate air pollutants emitted into the ambient air by stationary and mobile sources. These regulated air pollutants are known as “criteria air pollutants” and are categorized as primary and secondary standards. Primary standards are set of limits based on human health. Another set of limits intended to prevent environmental and property damage is called secondary standards. Criteria pollutants are defined by state and federal law as a risk to the health and welfare of the general public.

Page 17: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 6

The following specific descriptions of health effects for each air pollutant associated with Project construction and operation are based on U.S. Environmental Protection Agency (USEPA; 2007) and California Air Resources Board (CARB; 2009).

Ozone. O3 is considered a photochemical oxidant, which is a chemical that is formed when VOCs and oxides of nitrogen (NOX), both by products of fuel combustion, react in the presence of ultraviolet light. Ozone is considered a respiratory irritant and prolonged exposure can reduce lung function, aggravate asthma and increase susceptibility to respiratory infections. Children and those with existing respiratory diseases are at greatest risk from exposure to ozone.

Carbon Monoxide. CO is a product of fuel combustion, and the main source of CO in the SDAB is from motor vehicle exhaust. CO is an odorless, colorless gas. CO affects red blood cells in the body by binding to hemoglobin and reducing the amount of oxygen that can be carried to the body’s organs and tissues. CO can cause health effects to those with cardiovascular disease, and can also affect mental alertness and vision.

Nitrogen Dioxide. NO2 is also a by-product of fuel combustion, and is formed both directly as a product of combustion and in the atmosphere through the reaction of nitric oxide (NO) with oxygen. NO2 is a respiratory irritant and may affect those with existing respiratory illness, including asthma. NO2 can also increase the risk of respiratory illness.

Respirable Particulate Matter and Fine Particulate Matter. Respirable particulate matter, or PM10, refers to particulate matter with an aerodynamic diameter of 10 microns or less. Fine particulate matter, or PM2.5, refers to particulate matter with an aerodynamic diameter of 2.5 microns or less. Particulate matter in these size ranges has been determined to have the potential to lodge in the lungs and contribute to respiratory problems. PM10 and PM2.5 arise from a variety of sources, including road dust, diesel exhaust, fuel combustion, tire and brake wear, construction operations and windblown dust. PM10 and PM2.5 can increase susceptibility to respiratory infections and can aggravate existing respiratory diseases such as asthma and chronic bronchitis. PM2.5 is considered to have the potential to lodge deeper in the lungs.

Sulfur dioxide. Sulfur dioxide (SO2) is a colorless, reactive gas that is produced from the burning of sulfur-containing fuels such as coal and oil, and by other industrial processes. Generally, the highest concentrations of SO2 are found near large industrial sources. SO2 is a respiratory irritant that can cause narrowing of the airways leading to wheezing and shortness of breath. Long-term exposure to SO2 can cause respiratory illness and aggravate existing cardiovascular disease.

Lead. Lead (Pb) in the atmosphere occurs as particulate matter. Pb has historically been emitted from vehicles combusting leaded gasoline, as well as from industrial sources. With the phase-out of leaded gasoline, large manufacturing facilities are the sources of the largest amounts of lead emissions. Pb has the potential to cause gastrointestinal, central nervous system, kidney and blood diseases upon prolonged exposure. Pb is also classified as a probable human carcinogen.

Sulfates. Sulfates are the fully oxidized ionic form of sulfur. In California, emissions of sulfur compounds occur primarily from the combustion of petroleum-derived fuels (e.g., gasoline and diesel fuel) that contain sulfur. This sulfur is oxidized to SO2 during the combustion process and

Page 18: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 7

subsequently converted to sulfate compounds in the atmosphere. The conversion of SO2 to sulfates takes place comparatively rapidly and completely in urban areas of California due to regional meteorological features. The CARB’s sulfates standard is designed to prevent aggravation of respiratory symptoms. Effects of sulfate exposure at levels above the standard include a decrease in ventilatory function, aggravation of asthmatic symptoms and an increased risk of cardio-pulmonary disease. Sulfates are particularly effective in degrading visibility, and due to fact that they are usually acidic, can harm ecosystems and damage materials and property.

Hydrogen Sulfide. Hydrogen sulfide (H2S) is a colorless gas with the odor of rotten eggs. It is formed during bacterial decomposition of sulfur-containing organic substances. Also, it can be present in sewer gas and some natural gas, and can be emitted as the result of geothermal energy exploitation. Breathing H2S at levels above the standard would result in exposure to a very disagreeable odor. In 1984, a CARB committee concluded that the ambient standard for H2S is adequate to protect public health and to significantly reduce odor annoyance.

Vinyl Chloride. Vinyl chloride, a chlorinated hydrocarbon, is a colorless gas with a mild, sweet odor. Most vinyl chloride is used to make polyvinyl chloride (PVC) plastic and vinyl products. Vinyl chloride has been detected near landfills, sewage plants and hazardous waste sites, due to microbial breakdown of chlorinated solvents. Short-term exposure to high levels of vinyl chloride in air causes central nervous system effects, such as dizziness, drowsiness and headaches. Long-term exposure to vinyl chloride through inhalation and oral exposure causes liver damage.

Visibility-Reducing Particles. Visibility-reducing particles consist of suspended particulate matter, which is a complex mixture of tiny particles that consists of dry solid fragments, solid cores with liquid coatings, and small droplets of liquid. These particles vary greatly in shape, size and chemical composition, and can be made up of many different materials such as metals, soot, soil, dust, and salt. These particles in the atmosphere would obstruct the range of visibility. This standard is intended to limit the frequency and severity of visibility impairment due to regional haze.

2.2.2 Toxic Air Contaminants

The Health and Safety Code (§39655, subd. (a).) defines a toxic air contaminant (TAC) as “an air pollutant which may cause or contribute to an increase in mortality or in serious illness, or which may pose a present or potential hazard to human health.” A substance that is listed as a hazardous air pollutant pursuant to subsection (b) of Section 112 of the Federal Clean Air Act (CAA) (42 United States Code Sec. 7412[b]) is a TAC. Under State law, the California Environmental Protection Agency (CalEPA), acting through CARB, is authorized to identify a substance as a TAC if it determines the substance is an air pollutant that may cause or contribute to an increase in mortality or an increase in serious illness, or that may pose a present or potential hazard to human health.

2.3 REGULATORY SETTING

Air quality is defined by ambient air concentrations of specific pollutants identified by the USEPA to be of concern with respect to health and welfare of the general public. The USEPA is

Page 19: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 8

responsible for enforcing the Federal CAA of 1970 and its 1977 and 1990 Amendments. The CAA required the USEPA to establish National Ambient Air Quality Standards (NAAQS), which identify concentrations of pollutants in the ambient air below which no adverse effects on the public health and welfare are anticipated. In response, the USEPA established both primary and secondary standards for several criteria pollutants, which are introduced above. Table 1, California and National Ambient Air Quality Standards, shows the federal and state ambient air quality standards for these pollutants.

The CAA allows states to adopt ambient air quality standards and other regulations provided they are at least as stringent as federal standards. The CARB has established the more stringent California Ambient Air Quality Standards (CAAQS) for the six criteria pollutants through the California Clean Air Act of 1988 (CCAA), and also has established CAAQS for additional pollutants, including sulfates, H2S, vinyl chloride and visibility-reducing particles. Areas that do not meet the NAAQS or the CAAQS for a particular pollutant are considered to be “nonattainment areas” for that pollutant. On April 30, 2012, the SDAB was classified as a marginal nonattainment area for the 8-hour NAAQS for ozone (CARB 2015b). The SDAB is an attainment area for the NAAQS for all other criteria pollutants. The SDAB currently falls under a national “maintenance plan” for CO, following a 1998 redesignation as a CO attainment area (SDAPCD 2010). The SDAB is currently classified as a nonattainment area under the CAAQS for ozone (serious nonattainment), PM10, and PM2.5 (CARB 2014).

The CARB is the state regulatory agency with authority to enforce regulations to both achieve and maintain the NAAQS and CAAQS. The local air district has the primary responsibility for the development and implementation of rules and regulations designed to attain the NAAQS and CAAQS, as well as the permitting of new or modified sources, development of air quality management plans, and adoption and enforcement of air pollution regulations. The SDAPCD is the local agency responsible for the administration and enforcement of air quality regulations for the County.

Page 20: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 9

Table 1 CALIFORNIA AND NATIONAL AMBIENT AIR QUALITY STANDARDS

Pollutant Averaging Time California Standards

Federal Standards Primarya Secondaryb

O3 1 Hour 0.09 ppm

(180 µg/m3) – –

8 Hour 0.070 ppm (137 µg/m3)

0.075 ppm (147 µg/m3) Same as Primary

PM10 24 Hour 50 µg/m3 150 µg/m3 Same as Primary AAM 20 µg/m3 – Same as Primary

PM2.5 24 Hour – 35 µg/m3 Same as Primary AAM 12 µg/m3 12.0 µg/m3 Same as Primary

CO

1 Hour 20 ppm (23 mg/m3)

35 ppm (40 mg/m3) –

8 Hour 9.0 ppm (10 mg/m3)

9 ppm (10 mg/m3) –

8 Hour (Lake Tahoe)

6 ppm (7 mg/m3) – –

NO2

AAM 0.030 ppm (57 µg/m3)

0.053 ppm (100 µg/m3) Same as Primary

1 Hour 0.18 ppm (339 µg/m3)

0.100 ppm (188 µg/m3) –

SO2

24 Hour 0.04 ppm (105 µg/m3) – –

3 Hour – – 0.5 ppm (1,300 µg/m3)

1 Hour 0.25 ppm (655 µg/m3)

0.075 ppm (196 µg/m3) –

Lead

30-day Avg. 1.5 µg/m3 – – Calendar Quarter – 1.5 µg/m3

Same as Primary Rolling 3-month Avg. – 0.15 µg/m3

Visibility Reducing Particles

8 hour

Extinction coefficient of 0.23 per km – visibility

≥ 10 miles (0.07 per km – ≥30 miles

for Lake Tahoe) No Federal

Standards Sulfates 24 Hour 25 µg/m3 Hydrogen

Sulfide 1 Hour 0.03 ppm (42 µg/m3)

Vinyl Chloride 24 Hour 0.01 ppm

(26 µg/m3) Source: CARB 2013. Note: More detailed information in the data presented in this table can be found at the CARB website (www.arb.ca.gov). O3: ozone; ppm: parts per million; µg/m3

: micrograms per cubic meter; PM10: large particulate matter; AAM: Annual Arithmetic Mean; PM2.5: fine particulate matter; CO: carbon monoxide; mg/m3: milligrams per cubic meter; NO2 nitrogen dioxide; SO2: sulfur dioxide; km: kilometer; –: No Standard. a National Primary Standards: The levels of air quality necessary, within an adequate margin of safety, to protect the public health. b National Secondary Standards: The levels of air quality necessary to protect the public welfare from any known or anticipated

adverse effects of a pollutant.

Page 21: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 10

The SDAPCD and San Diego Association of Governments (SANDAG) are responsible for developing and implementing the clean air plan for attainment and maintenance of the ambient air quality standards in the SDAB. The County Regional Air Quality Strategy (RAQS) was initially adopted in 1991, and is updated on a triennial basis. The most recent version of the RAQS was adopted by the SDAPCD in 2009. The local RAQS, in combination with those from all other California nonattainment areas with serious (or worse) air quality problems, is submitted to the CARB, which develops the California State Implementation Plan (SIP).

The RAQS relies on information from CARB and SANDAG, including mobile and area source emissions, as well as information regarding projected growth in the County, to project future emissions and then determine from that the strategies necessary for the reduction of emissions through regulatory controls. The CARB mobile source emission projections and SANDAG growth projections are based on population and vehicle trends and land use plans developed by the cities and by the County as part of the development of the County’s General Plan.

The SIP relies on the same information from SANDAG to develop emission inventories and emission reduction strategies that are included in the attainment demonstration for the air basin.

The current federal and state attainment status (Table 2, Federal and State Air Quality Designation) for the County is as follows:

Table 2 FEDERAL AND STATE AIR QUALITY DESIGNATION

Criteria Pollutant Federal Designation State Designation

Ozone (1-hour) (No federal standard) Nonattainment Ozone (8-hour) Nonattainment Nonattainment CO Maintenance Attainment PM10 Unclassifiable Nonattainment PM2.5 Attainment Nonattainment NO2 Attainment Attainment SO2 Attainment Attainment Lead Attainment Attainment Sulfates (No federal standard) Attainment Hydrogen Sulfide (No federal standard) Unclassifiable Visibility (No federal standard) Unclassifiable Source: CARB 2014 and USEPA 2015b

2.4 BACKGROUND AIR QUALITY

The SDAPCD operates a network of ambient air monitoring stations throughout the County. The purpose of the monitoring stations is to measure ambient concentrations of the pollutants and determine whether the ambient air quality meets the CAAQS and the NAAQS. The nearest ambient monitoring stations to the Project site is the Chula Vista monitoring station located at 80 East J Street. The Chula Vista monitoring station does not monitor for CO, therefore, data

Page 22: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 11

from the San Diego Beardsley Street station was used to represent the area’s ambient CO concentrations. Air quality data are shown on Table 3, Air Quality Monitoring Data.

Monitoring data at the Chula Vista station has had acceptable levels of the criteria air pollutants CO, NO2, and PM2.5 for 2012 to 2014. Violations of the state and federal 8-hour standards for ozone occurred in 2012 and 2014. The state annual PM10 standard was exceeded each of the three years.

Table 3 AIR QUALITY MONITORING DATA

Air Pollutant 2012 2013 2014

Ozone Max 1-hour (ppm) Days > CAAQS (0.09 ppm)

0.085 0

0.073 0

0.093 0

Max 8-hour (ppm) Days > NAAQS (0.075 ppm) Days > CAAQS (0.070 ppm)

0.078 1 1

0.062 0 0

0.072 0 1

Particulate Matter (PM10) Max Daily (µg/m3) Days > NAAQS (150 µg/m3) Days > CAAQS (50 µg/m3)

38.0 0 0

40.0 0 0

39.0 0 0

Annual Average (µg/m3) Exceed CAAQS (20 µg/m3)

21.5 Yes

29.7 Yes

23.4 Yes

Particulate Matter (PM2.5) Max Daily (µg/m3) Days > NAAQS (35 µg/m3)

34.3 0

21.9 0

26.5 0

Annual Average (µg/m3) Exceed NAAQS (15 µg/m3) Exceed CAAQS (12 µg/m3)

10.2 No No

9.4 No No

9.2 No No

Nitrogen Dioxide (NO2) Max 1-hour (ppm) Days > NAAQS (0.10 ppm) Days > CAAQS (0.18 ppm)

0.057 0 0

0.057 0 0

0.055 0 0

Annual Average (ppm) Exceed NAAQS (0.053 ppm) Exceed CAAQS (0.030 ppm)

0.011 No No

0.011 No No

0.011 No No

Carbon Monoxide (CO) Max 8-hour (ppm) Days > NAAQS (9.0 ppm) Days > CAAQS (9.0 ppm)

1.81 0 0

No Data - -

No Data - -

Max 1-hour (ppm) Days > NAAQS (35 ppm) Days > CAAQS (20 ppm)

4.4 0 0

3.2 0 0

3.5 0 0

Sources: CARB 2015a (www.arb.ca.gov); USEPA 2015a (http://www.epa.gov/airdata/ad_rep_con.html) (Used for 1-hour CO) > = exceeding; ppm = parts per million; µg/m3 = micrograms per cubic meter; Standard Mean = Annual Arithmetic Mean; No Data = Insufficient data available to determine the value.

Page 23: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 12

3.0 SIGNIFICANCE CRITERIA AND ANALYSIS METHODOLOGIES

3.1 SIGNIFICANCE CRITERIA

The City (2011) has approved guidelines for determining significance based on Appendix G.III of the State California Environmental Quality Act (CEQA) Guidelines, which provide guidance that a project would have a significant environmental impact if it would:

1. Conflict with or obstruct the implementation of the San Diego RAQS or applicable portions of the SIP;

2. Result in emissions that would violate any air quality standard or contribute substantially to an existing or projected air quality violation;

3. Result in a cumulatively considerable net increase for which the SDAB is in non-attainment of NAAQS or CAAQS;

4. Expose sensitive receptors (including, but not limited to, residences, schools, hospitals, resident care facilities, or day-care centers) to substantial pollutant concentrations;

5. Create objectionable odors affecting a substantial number of people.

To determine whether a project would (a) result in emissions that would violate any air quality standard or contribute substantially to an existing or projected air quality violation, or (b) result in a cumulatively considerable net increase of PM10 or exceed quantitative thresholds for ozone precursors, oxides of nitrogen and VOCs, project emissions may be evaluated based on the quantitative emission thresholds established by the SDAPCD. As part of its air quality permitting process, the SDAPCD has established thresholds in Rule 20.2 for the preparation of Air Quality Impact Assessments (AQIAs). The SCAQMD’s screening threshold of 55 pounds per day or 10 tons per year is being applied to this analysis as a significance threshold for PM2.5.

For CEQA purposes, these screening criteria can be used as numeric methods to demonstrate that a project’s total emissions would not result in a significant impact to air quality. The screening thresholds are included in Table 4, Screening-level Thresholds for Air Quality Impact Analysis.

Page 24: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 13

Table 4 SCREENING-LEVEL THRESHOLDS FOR AIR QUALITY IMPACT ANALYSIS

Pollutant Total Emissions

Construction Emissions (Pounds per Day)

Respirable Particulate Matter (PM10) 100 Fine Particulate Matter (PM2.5) 55 Oxides of Nitrogen (NOX) 250 Oxides of Sulfur (SOX) 250 Carbon Monoxide (CO) 550 Volatile Organic Compounds (VOCs) 75

Operational Emissions Pounds per

Hour Pounds per

Day Tons per

Year Respirable Particulate Matter (PM10) --- 100 15 Fine Particulate Matter (PM2.5) --- 55 10 Oxides of Nitrogen (NOX) 25 250 40 Oxides of Sulfur (SOX) 25 250 40 Carbon Monoxide (CO) 100 550 100 Lead and Lead Compounds --- 3.2 0.6 Volatile Organic Compounds (VOC) --- 75 13.7

Toxic Air Contaminant Emissions

Excess Cancer Risk 1 in 1 million 10 in 1 million with T-BACT

Non-Cancer Hazard 1.0 Source: SDACPD Rule 20.2 and Rule 1210. T-BACT = Toxics Best Available Control Technology

3.2 METHODOLOGY

Air emissions were calculated using the California Emissions Estimator Model (CalEEMod), Version 2013.2.2 (SCAQMD 2013). CalEEMod is a computer model used to estimate air emissions resulting from land development projects throughout the state of California. CalEEMod was developed by the SCAMQD with the input of several air quality management and pollution control districts.

In brief, CalEEMod is a computer model that estimates criteria air pollutant and greenhouse gas emissions from mobile (i.e., vehicular) sources, area sources (fireplaces, woodstoves, and landscape maintenance equipment), energy use (electricity and natural gas used in space heating, ventilation, and cooling; lighting; and plug-in appliances), water use and wastewater generation, and solid waste disposal. Emissions are estimated based on land use information input to the model by the user.

In the first module, the user defines the specific land uses that will occur at the project site. The user also selects the appropriate land use setting (urban, suburban, or rural), operational year, location, climate zone, and utility provider. The input land uses, size features, and population are used throughout CalEEMod in determining default variables and calculations in each of the subsequent modules. The input land use information consists of land use subytpes (such as the

Page 25: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 14

residential subtypes of single-family residential and multi-family medium-rise residential) and their unit or square footage quantities.

Subsequent modules include construction (including off-road vehicle emissions), mobile (on-road vehicle emissions), area sources (woodstoves, fireplaces, consumer products [cleansers, aerosols, solvents], landscape maintenance equipment, architectural coatings), water and wastewater, and solid waste. Each module comprises multiple components including an associated mitigation module to account for further reductions in the reported baseline calculations. Other inputs include trip generation rates, trip lengths, vehicle fleet mix (percentage autos, medium truck, etc.), trip distribution (i.e., percent work to home, etc.), duration of construction phases, construction equipment usage, grading areas, season, and ambient temperature, as well as other parameters.

In various places the user can input additional information and/or override the default assumptions to account for project- or location-specific parameters. For this assessment the default parameters including vehicle trip lengths and energy intensity factors were not changed unless otherwise noted. The input data and reported criteria pollutant emission estimates based on these inputs are discussed below. The CalEEMod input and output files are included in Appendix A.

4.0 PROJECT IMPACTS

This section evaluates potential direct impacts of the proposed Project related to the air pollutant emissions. The focus is on the effects of future development carried out in accordance with the SYCPU and SYHVSP.

4.1 SYCPU

4.1.1 Conformance to the Regional Air Quality Strategy

The RAQS outlines SDAPCD’s plans and control measures designed to attain the CAAQS for ozone. In addition, the SDAPCD relies on the SIP, which includes the SDAPCD’s plans and control measures for attaining the ozone NAAQS. These plans accommodate emissions from all sources, including natural sources, through implementation of control measures, where feasible, on stationary sources to attain the standards. Mobile sources are regulated by the CalEPA and the CARB, and the emissions and reduction strategies related to mobile sources are considered in the RAQS and SIP.

The RAQS relies on information from CARB and SANDAG, including projected growth in the County, mobile, area and all other source emissions in order to project future emissions and determine from that the strategies necessary for the reduction of stationary source emissions through regulatory controls. The CARB mobile source emission projections and SANDAG growth projections are based on population and vehicle trends, and land use plans developed by the cities and by the County. As such, projects that propose development that is consistent with the growth anticipated by the general plans would be consistent with the RAQS. In the event that a project proposes development which is less dense than anticipated within the General Plan,

Page 26: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 15

the project would likewise be consistent with the RAQS. If a project proposes development that is greater than that anticipated in the County General Plan and SANDAG’s growth projections upon which the RAQS is based, the project would be in conflict with the RAQS and SIP, and might have a potentially significant impact on air quality. This situation would warrant further analysis to determine if the proposed project and the surrounding projects exceed the growth projections used in the RAQS for the specific subregional area.

The RAQS includes anticipated growth associated with the currently adopted community plan. Amending the SYCPU to change development from the adopted community plan potential would, necessarily, result in an inconsistency between the RAQS and the proposed community plan update. Relative to the adopted community plan, the proposed SYCPU would:

• increase the number of residential units by 30 percent;

• increase the amount of land designated for retail/commercial by 7 percent;

• increase the amount of land designated for institutional uses by 11 percent; and

• decrease the amount of land designated for industrial uses by 2 percent.

Due to these land use changes, the SYCPU is not consistent with the RAQS, however, as discussed in the traffic impact analysis prepared for the SYCPU, the adopted community plan land use designations would be expected to generate more average daily trips (ADT) than the uses that would be allowed under the proposed SYCPU (472,023 ADT compared to 407,233 ADT) (Kimley-Horn 2015). Thus, while the proposed land uses under the SYCPU were not included in the emissions assumptions contained within the RAQS, the vehicle trips from the SYCPU are less than those anticipated from the adopted community plan, and would result in lower mobile source emissions. Thus, even though it was not assumed in the RAQS, the proposed SYCPU is therefore generally consistent with the intent of the RAQS, and would not impede the goals contained within the RAQS.

Another measurement tool in determining consistency with the RAQS is to determine how a project accommodates the expected increase in population or employment. Generally, if a project is planned in a way that results in the minimization of VMT both within the project and the community in which it is located, and consequently the minimization of air pollutant emissions, that aspect of the project is consistent with the RAQS. The proposed SYCPU would be consistent with the goals of the RAQS to develop compact, walkable communities close to transit connections and consistent with smart growth principles. The SYCPU proposes to establish two pedestrian-oriented, urban, and mixed-use community villages that would reduce reliance on the automobile, and promote walking and use of alternative transportation. The SYCPU supports the multi-modal strategy of the San Diego Association of Governments (SANDAG) Regional Plan (RP) through the designation of two villages along a trolley corridor, as well as a planned Intermodal Transit Center that would accommodate several transportation modes. Policies contained within the proposed SYCPU Land Use and Mobility Elements would serve to promote bus transit use as well as other forms of mobility, including walking and bicycling. This type of development is consistent with the goals of the RAQS for reducing the emissions associated with new development.

Page 27: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 16

Emissions projections used to establish SDAB attainment objectives reflect adopted regional and local land use plans. Therefore, the emissions associated with the proposed SYCPU are within the amounts already accounted for in the RAQS, and no inconsistency with the RAQS would occur. Thus, the impact would be less than significant, and no mitigation is required.

4.1.2 Conformance to Federal and State Ambient Air Quality Standards

Future development pursuant to the SYCPU would generate criteria pollutants in the short term during construction and the long term during operation. To determine whether a project would result in emissions that would violate any air quality standard or contribute substantially to an existing or projected air quality violation, a project’s emissions are evaluated based on the quantitative emission thresholds established by the SDAPCD (as shown in Table 4).

Construction

Construction activities associated with new land uses proposed under the SYCPU would result in emissions of fugitive dust from demolition and site grading activities, heavy construction equipment exhaust, and vehicle trips associated with workers commuting to and from the site and trucks hauling materials. The exact number and timing of individual development projects that would occur as a result of implementation of the SYCPU are unknown at this time and therefore project-level emission estimates cannot be determined at the program level. Subsequent development projects would need to analyze specific construction-related criteria air pollutant impacts to ensure that emissions remain below SDAPCD thresholds. Because of the likely potential of individual projects to exceed SDAPCD screening thresholds, implementation of the SYCPU would result in potentially significant impacts related to construction emissions.

Operation

Operational source emissions would originate from traffic generated within or as a result of future development pursuant to the proposed SYCPU. Area source emissions would result from activities such as the use of fireplaces and consumer products. In addition, landscape maintenance activities associated would the proposed land uses would produce pollutant emissions.

SYCPU Characteristic Assumptions

CalEEMod prompts the user to enter a given project’s location, setting, climate zone, utility provider, operational year, and the specific land uses that will occur. For this analysis, the location was selected as San Diego County with an urban (versus suburban or rural) setting, in climate zone 13, served by San Diego Gas & Electric (SDG&E). The operational year was conservatively set to 2020.

Land Use Assumptions

For comparative purposes, air emissions were calculated for the existing land uses, and the proposed SYCPU land use plan using CalEEMod 2013.2.2. Table 5, Existing and Future SYCPU Land Uses, summarizes the existing and future build out land uses entered into CalEEMod (Kimley-Horn 2015).

Page 28: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 17

Table 5 EXISTING AND FUTURE SYCPU LAND USES

Land Use Existing Existing to Remain

Proposed New Development

SYCPU Total

Financial Institution (square feet) 17,700 11,500 - 11,500 City Park (acres) 35.8 35.8 46.1 81.9 Multi-Family Residential (dwelling units) 4,476 4,479 2,930 7,406 Convenience Market (square feet) 2,700 - - - Convenience Market with Gas Pumps (pumps) 84 84 - 84 Elementary School (students) 4,108 4,108 635 4,743 Transportation (acre) 9.8 6.7 - 6.7 Fast Food Restaurant (square feet) 45,400 44,900 - 44,900 General Light Industry (square feet) 1,309,800 1,281,500 - 1,281,500 General Office Building (square feet) 7,000 7,000 - 7,000 Government (Civic Center) (square feet) 12,900 6,000 - 6,000 Government Office Building (square feet) 317,500 317,500 48,700 366,200 High School (square feet) 37,600 37,600 96,700 134,300 High Turnover Restaurant (square feet) 40,000 22,400 - 22,400 Hotel (rooms) 756 756 - 756 Industrial Park (square feet) 46,900 46,900 - 46,900 Junior College (students) 2,300 2,300 - 2,300 Junior High School (students) 993 993 141 1,134 Library (square feet) 4,300 4,300 10,700 15,000 Medical Office Building (square feet) 48,300 48,300 - 48,300 Mobile Home Park (dwelling units) 532 419 - 419 Motel (rooms) 35 35 - 35 Park and Ride Lot (spaces) 7,987 7,987 3,057 11,044,000 Place of Worship (square feet) 175,500 175,500 - 175,500 Regional Shopping Center (square feet) 1,443,400 1,443,400 909,800 2,353,200 Single Family Residential (dwelling units) 2,339 2,183 - 2,183 Strip Mall (square feet) 507,200 507,200 518,100 1,025,300 Supermarket (square feet) 23,000 - - - Warehouse (square feet) 11,500 11,500 22,800 34,300 Source: Kimley-Horn 2015

Portions of existing developed lands within the plan area would remain, and likely not change as part of the proposed SYCPU. These include single-family residences, recently constructed multi-family residences, recently entitled projects, and existing major public and institutional uses. Because these existing developed land uses were built to older, less stringent code requirements than those applicable to future development or re-development, the existing developed land uses that will remain and not change, and the land uses that would be developed or re-developed as part of the buildout of the proposed SYCPU would have different energy consumptions associated with them. In order to reflect these energy consumption differences, emissions were estimated using two separate CalEEMod runs for the land uses in the proposed SYCPU. These runs are discussed in further detail below.

Page 29: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 18

The quantities listed in Table 5 include the existing developed land uses that were assumed to remain and not be redeveloped as part of the SYCPU, and the proposed new development. It was assumed that the energy-related emissions associated with the existing land uses that would not be redeveloped were related to older energy codes, while those associated with new development project would be the result of recent energy code revisions. The two model runs were then added together to obtain the total project emissions associated with the SYCPU buildout.

Estimating Vehicle Emissions

CalEEMod estimates vehicle emissions by first calculating trip rate, trip length, trip purpose, and trip type percentages (e.g., home to work, home to shop, home to other) for each land use type, based on the land use types and quantities entered by the user in the land use module. For this analysis, the CalEEMod default trip rates were edited to reflect the trip rates identified for each land use subtype in the traffic impact analysis prepared for the SYCPU (Kimley-Horn 2015). The model’s default trip lengths, purpose, and types were not edited.

Estimating Energy Use Emissions

Air pollutants are emitted as a result of activities in buildings for which natural gas are used as an energy source. CalEEMod estimates emissions from energy use by multiplying average rates of residential and non-residential energy consumption by the quantities of residential units and non-residential square footage entered in the land use module to obtain total projected energy use. This value is then multiplied by the natural gas air pollutant emission factors applicable to the project location and utility provider.

CalEEMod default energy values are based on the California Energy Commission- (CEC) sponsored California Commercial End Use Survey (CEUS) and Residential Appliance Saturation Survey (RASS) studies, which identify energy use by building type and climate zone. Each land use type input to the land use module is mapped in the energy module to the appropriate CEUS and RASS building type. Because these studies are based on older buildings, adjustments have been made in CalEEMod to account for changes to Title 24 building codes. The default adjustment is to the 2008 Title 24 energy code (part 6 of the building code). Adjustments to simulate the 2005 Title 24 energy code are available in the model by selecting the “use historical data” box. The CalEEMod User’s Guide states that “a user should select the use historical box if they only want an adjustment to the 2005 standard which were in effect when CARB developed its Scoping Plan 2020 No Action Taken (i.e., business as usual [BAU]) predictions” (ENVIRON 2013). Therefore, the historical data box was selected in order to reflect emissions from energy use as associated with a building built to the 2005 Title 24 energy code.

The current 2013 Title 24 energy code results in a 25 to 30 percent reduction in energy use over the 2008 Title 24 standards. For the estimates of the SYCPU, energy emissions were estimated using two runs of the model. One run assumed a 25 percent reduction over the default 2008 Title 24 energy code for the portion of the total buildout land use quantities that would be new (i.e., the Proposed New Development land uses), and therefore constructed in accordance with the 2013 Title 24 energy code. The second model run for the SYCPU selected the historical data box for the portion of the total buildout land use quantities that comprise existing land uses that

Page 30: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 19

would not change (i.e., the Existing to Remain land uses). The two model runs were then added together to obtain the total projected energy emissions associated with the SYCPU buildout. Table 5 lists the buildout land use quantities that were input to the Existing to Remain and Proposed New Development CalEEMod energy module runs.

Estimating Area Source Emissions

This CalEEMod module estimates the emissions that would occur from the use of hearths, woodstoves, and landscaping equipment. This module also estimates emissions due to use of consumer products and architectural coatings that have VOCs. The use of hearths and woodstoves directly emits air pollutants from the combustion of natural gas, wood, or biomass, some of which are thus classified as biogenic. CalEEMod estimates emissions from hearths and woodstoves only for residential uses based on the type and size of features of the residential land use inputs.

The use of landscape equipment emits air pollutants associated with the equipment’s fuel combustion. CalEEMod estimates the number and type of equipment needed based on the number of summer days given the project’s location as entered in the project characteristics module. The model defaults for hearths, woodstoves, and landscaping equipment were assumed.

Architectural VOC emissions for operations are primarily associated with maintenance activities. These activities are not covered under CALGreen. However, coatings sold in the County must comply with SDAPCD Rule 67.0. As a worst-case, the upper end SDAPCD architectural coating VOC limit of 250 milligrams per liter was used in each run.

Total Operational Emissions

A summary of the modeling results, which includes mobile, area, and energy source emissions, is shown in Table 6, Average Daily Operational Emissions. As seen in Table 6, total future reactive organic gas (ROG), CO, SO2, PM10, and PM2.5 emissions under the proposed SYCPU are projected to be greater than existing conditions. This is due to the increase in development associated with buildout of the SYCPU.

As shown in Table 6, SYCPU emissions of the criteria pollutants ROG, CO, PM10, and PM2.5 during operation would exceed the daily thresholds. Therefore, operation of the SYCPU would result in a significant impact on air quality.

Page 31: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 20

Table 6 AVERAGE DAILY OPERATIONAL EMISSIONS

(pounds per day)

Emission Sources VOC NOX CO SO2 PM10 PM2.5 Existing Emissions (Year 2010) Area Sources 11,831 160 14,499 5 1,949 1,949 Energy Sources 8 72 45 <1 6 6 Vehicular (Mobile) Sources 1,143 2,152 10,327 15 1,101 313 Total Existing 12,983 2,384 24,871 21 3,056 2,268 SYCPU Emissions (Year 2020) Area Sources 16,104 217 19,699 7 2,655 2,655 Energy Sources 9 78 48 <1 6 6 Vehicular (Mobile) Sources 1,163 1,978 10,177 24 1,691 470 Total SYCPU 17,275 2,274 29,923 32 4,352 3,131 Net SYCPU Emissions 4,293 (110) 5,053 10 1,296 863 Screening Level Thresholds 75 250 550 250 100 55 Exceed Threshold? Yes No Yes No Yes Yes Source: CalEEMod output data is provided in Appendix A Note: CalEEMod mobile sources emissions were adjusted to remove the greenhouse gas (GHG) reductions from the

Pavley I and (Low Carbon Fuel Standards (LCFS). Totals may not add up exactly due to rounding. 4.1.3 Cumulatively Considerable Net Increase of Criteria Pollutants

The cumulative area for regional air quality analysis is the SDAB. The SDAB is designated as a nonattainment area for ozone, PM10, and PM2.5 under State and/or federal standards. The RAQS is the most appropriate document for evaluating the SYCPU’s cumulative effects because the RAQS evaluated air quality emissions for the whole of the SDAB using a future development scenario. According to Section 4.1.1 of this report, the proposed SYCPU would conflict with implementation of the RAQS. Furthermore, as discussed under Section 4.1.2, the proposed SYCPU’s operational regional ROG (an ozone precursor), PM10, and PM2.5 emissions would exceed the SDAPCD’s Screening Level Thresholds. Because it cannot be demonstrated at the programmatic level, that future development would not exceed applicable air quality standards, impacts are considered cumulatively considerable and significant. Thus, the SYCPU’s ROG emissions could contribute to existing violations of the State and federal ozone standards; the PM10 and PM2.5 emissions could also contribute to existing violations of their respective standards.

4.1.4 Impacts to Sensitive Receptors

Impacts to sensitive receptors are typically analyzed for operational period CO hot spots, and exposure to TACs. An analysis of the SYCPU’s potential to expose sensitive receptors to these pollutants is provided below.

Carbon Monoxide Hot Spots

A CO hot spot is an area of localized CO pollution caused by severe vehicle congestion on major roadways, typically near intersections. If a project increases average delay at signalized

Page 32: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 21

intersections operating at Level of Service (LOS) E or F, or causes an intersection that would operate at LOS D or better without the project to operate at LOS E or F with the project, a quantitative screening is required. According to the SYCPU Traffic Impact Analysis, 25 of the 48 intersections analyzed within the plan area would have a cumulative traffic related impact before inclusion of the recommended traffic mitigation measures (Kimley-Horn 2015). As such, there would be a potential for a CO hot spot or exposure of sensitive receptors to substantial CO emissions. Therefore, CO hot spot impacts would be potentially significant.

Exposure to Toxic Air Contaminants

Stationary Sources

The SYCPU includes land uses which may generate air pollutants affecting adjacent sensitive land uses. In air quality terms, individual land uses that emit air pollutants in sufficient quantities are known as stationary sources. The primary concern with stationary sources is local, however, they also contribute to air pollution in the SDAB. Stationary sources include gasoline stations, power plants, dry cleaners, and other commercial and industrial uses. Stationary sources are regulated by the local air pollution control or management district through the issuance of permits; in this case, the agency is the SDAPCD.

The California Air Toxics Program establishes the process for the identification and control of toxic air contaminants and includes provisions to make the public aware of significant toxic exposures and for reducing risk. Additionally, AB 2588 was enacted in 1987, and requires stationary sources to report the types and quantities of certain substances routinely released into the air. The goals of the Air Toxics "Hot Spots" Act are to collect emission data, to identify facilities having localized impacts, to ascertain health risks, to notify nearby residents of significant risks, and to reduce those significant risks to acceptable levels.

In accordance with AB 2588, any new facility proposed that would have the potential to emit toxic air contaminants would be required to assess air toxic problems that would result from their facility’s emissions (SDAPCD 2010). If air emissions from a specific facility include toxic substances or exceed identified limits, the facility is required by the SDAPCD to provide information regarding emission inventories and health risk assessments. If adverse health impacts exceeding public notification levels are identified, the facility would provide public notice, and if the facility poses a potentially significant public health risk, the facility must submit a risk reduction audit and plan to demonstrate how the facility would reduce health risks. Thus, with this regulatory framework, at the program level, impacts associated with stationary sources in the SYCPU area would be less than significant.

Page 33: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 22

Table 7 CARB LAND USE SITING RECOMMENDATIONS

Source Category Recommended Buffer Distance (feet)

Freeways and High-Traffic Roads (freeways, urban roads with 100,000 vehicles per day, or rural roads with 50,000 vehicles per day)

500

Distribution Centers (that accommodate more than 100 trucks per day, more than 40 trucks with operating transport refrigeration units per day, or where transport refrigeration unit operations exceed 300 hours per week)

1,000

Chrome Platers 1,000 Dry Cleaners using Perchloroethylene (1 machine) 300 Dry Cleaners using Perchloroethylene (2 machines) 500

Dry Cleaners using Perchloroethylene (3 or more machines) Requires consultation with SDAPCD

Large Gas Station (3.6 million gallons or more per year) 300 Other Gas Stations 50 Source: CARB 2005

The proposed land uses within the SYCPU would include stationary sources of air pollutants as well as the potential for siting sensitive land uses in close proximity to stationary sources. Therefore, impacts associated with exposure of TACs to sensitive uses would be potentially significant.

Mobile Sources

The SYCPU contains several areas where new residential and other sensitive receptors could be placed within 500 feet of three major freeways (I-5, I-805, and SR-905). Based on the Table 7, these sensitive land uses could be exposed to unacceptable levels of DPM generated by diesel powered vehicles traveling these roadways. Furthermore, due to the community’s location near the San Ysidro international border crossing, the potential for DPM could be greater than other communities in San Diego due the anticipated higher percentage of truck traffic and the diminished vehicle emission controls installed on trucks registered in Mexico. Thus, impacts from DPMs are considered significant.

4.1.5 Odor Impacts

Although the SYCPU area is adjacent to numerous industrial operations, there are no known sources of specific, long-term odors in the area. There are no agricultural operations in the SYCPU area. The SYCPU would allow a variety of land uses that are not typically associated with the creation of objectionable odors. The SYCPU does not propose any specific new sources of odor that could affect sensitive receptors. Thus, impacts associated with odors are anticipated to be less than significant.

Page 34: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 23

4.2 SYHVSP

4.2.1 Conformance to the Regional Air Quality Strategy

The land uses which would occur within the SYHVSP would reflect the land use designations applied to the Specific Plan area by the SYCPU. As with the SYCPU, the land use designations within the SYHVSP would change which would create a potential inconsistency with the RAQS.

4.2.2 Conformance to Federal and State Ambient Air Quality Standards

As the land uses which would occur within the SYHVSP would reflect the land use designations applied to the Specific Plan area by the SYCPU, the emissions generated by future development of the SYHVSP are accounted for in the emissions evaluate for the SYCPU. As with general development within the SYCPU, new development within the SYHVSP would result in construction and operational emissions that could create emission levels that would exceed State and federal air quality standards and constitute a significant impact.

4.2.3 Cumulatively Considerable Net Increase of Criteria Pollutants

As discussed earlier, the proposed SYHVSP would conflict with implementation of the RAQS and operational regional emissions could result in significant impacts with respect to State and federal air quality standards. Thus, impacts would be cumulatively considerable and significant; the SYHVSP’s ROG emissions could contribute to existing violations of the State and federal ozone standards and the PM10 and PM2.5 emissions could contribute to existing violations of their respective standards.

4.2.4 Impacts to Sensitive Receptors

Carbon Monoxide Hot Spots

As the land uses which would occur within the SYHVSP would reflect the land use designations applied to the Specific Plan area by the SYCPU, the trips generated by future development of the SYHVSP are accounted for in the trips evaluate for the SYCPU. As with the SYCPU, there would be potential for a CO hot spot and exposure of sensitive receptors to substantial, local CO emissions. Thus, the impact would be potentially significant.

Exposure to Toxic Air Contaminants

Stationary Sources

The SYHVSP does not include any land uses which could generate TACs. As such, there is no potential for exposure of TACs to sensitive receptors from new stationary sources. Impacts would be less than significant.

Mobile Sources

The SYHVSP contains several areas where residential and other sensitive uses would be placed near to commercial uses and major roadways/freeways. CARB and SDAPCD provide guidance

Page 35: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 24

with the recommendation to site sensitive land uses outside specified buffers adjacent to or surrounding major emitters or facilities of concern. Sensitive uses located within the buffer distances of the facilities, indicated previously in Table 7, would be exposed to TACs. As with the SYCPU, impacts associated with exposure of TACs to sensitive uses would be potentially significant.

4.2.5 Odor Impacts

There are no known sources of specific, long-term odors in the area. There are no agricultural operations in the SYHVSP area. The SYHVSP would allow a variety of land uses that are not typically associated with the creation of objectionable odors. The SYHVSP does not propose any specific new sources of odor that could affect sensitive receptors. Impacts associated with odors are anticipated to be less than significant.

5.0 SUMMARY OF IMPACTS AND RECOMMENDED MEASURES

5.1 CONFORMANCE TO THE REGIONAL AIR QUALITY STRATEGY

Based on the analysis presented in Section 4.1, the land use designation changes associated with the SYCPU, the SYCPU and SYHVSP would, necessarily, result in an inconsistency between the RAQS and the proposed community plan update. However, as discussed in the traffic impact analysis prepared for the SYCPU, the adopted community plan land use designations would be expected to generate more ADT than the uses that would be allowed under the proposed SYCPU (472,023 ADT compared with 407,233 ADT) (Kimley-Horn 2015). Furthermore, the proposed SYCPU is intended to further express General Plan policies in the proposed SYCPU area through the provision of site-specific recommendations that implement city-wide goals and policies, address community needs, and guide zoning. Thus, while the proposed land uses under the SYCPU were not included in the emissions assumptions contained within the RAQS, the vehicle trips from the SYCPU are less than those anticipated from the adopted community plan and the goals and recommendations are consistent with development design guidelines, other mobility and civic guidelines, incentives, and programs in accordance with the general goals stated in the General Plan. Therefore, the emissions associated with the proposed SYCPU are within the amounts already accounted for in the RAQS, and no inconsistency with the RAQS would occur. Thus, the impact of the SYCPU on the RAQS would be less than significant and no mitigation would be required.

5.2 CONFORMANCE TO FEDERAL AND STATE AMBIENT AIR QUALITY STANDARDS

Criteria air pollutants generated during construction of new development pursuant to the SYCPU and SYHVSP could produce pollutants that would exceed State and federal requirements. Operational emissions would be associated with vehicle trips generated by the SYCPU and SYHVSP development, along with area sources such as energy use and landscaping. Based on the evaluation of air emissions, the SYCPU and SYHVSP emissions would exceed the screening-level thresholds for VOCs, CO, PM10, and PM2.5. Thus, the increase in future

Page 36: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 25

emissions of carbon monoxide, particulates, and ozone precursors associated with the SYCPU and SYHVSP would result in a significant air quality impact.

The following mitigation framework would reduce potential impacts of buildout under the SYCPU and SYHVSP on State and federal air quality standards. However, the ability of future development to successfully implement the actions required to fully meet these mitigation measures cannot be guaranteed at this time. Thus, air pollutant impacts from construction and operation under the proposed SYCPU and SYHVSP are considered significant and unavoidable at the program level.

AQ-1 To identify potential impacts resulting from construction activities, proposed development projects that are subject to CEQA shall have construction-related air quality impacts analyzed using the latest available CalEEMod model, or other analytical method determined in conjunction with the City. The results of the construction-related air quality impacts analysis shall be included in the development project’s CEQA documentation. If such analyses identify potentially significant regional or local air quality impacts based on the emissions thresholds presented in Table 4, the City shall require the incorporation of appropriate mitigation to reduce such impacts. Examples of potential mitigation measures are provided in Mitigation Measure AQ-2, below.

AQ-2 For individual construction project that would exceed daily emissions thresholds established by the City of San Diego, best available control measures/technology shall be incorporated to reduce construction emissions to the extent feasible. Best available control measures/technology include:

a) Minimizing simultaneous operation of multiple pieces of construction equipment;

b) Use of more efficient, or low pollutant emitting equipment, e.g., Tier III or Tier IV rated equipment;

c) Use of alternative fueled construction equipment;

d) Dust control measures for construction sites to minimize fugitive dust, (e.g. watering, soil stabilizers, and speed limits); and/or

e) Minimizing idling time by construction vehicles.

AQ-3 Each individual implementing development project shall submit a traffic control plan prior to the issuance of a grading permit. The traffic control plan shall describe in detail safe detours and provide temporary traffic control during construction activities for that project. To reduce traffic congestion, the plan shall include, as necessary, appropriate, and practicable, the following: temporary traffic controls such as a flag person during all phases of construction to maintain smooth traffic flow, dedicated turn lanes for movement of construction trucks and equipment on and off site, scheduling of construction activities that affect traffic flow on the arterial system to off-peak hour,

Page 37: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 26

consolidating truck deliveries, rerouting of construction trucks away from congested streets or sensitive receptors, and/or signal synchronization to improve traffic flow.

AQ-4 To identify potential impacts resulting from operational activities associated with future development, proposed development that are subject to CEQA shall have long-term operational-related air quality impacts analyzed using the latest available CalEEMod model, or other analytical method determined in conjunction with the City. The results of the operational-related air quality impacts analysis shall be included in the development project’s CEQA documentation. To address potential localized impacts, the air quality analysis shall incorporate a CO hot spot analysis, or other appropriate analyses, as determined by the City. If such analyses identify potentially significant regional or local air quality impacts based on the thresholds presented in Table 2 or Table 4, the City shall require the incorporation of appropriate mitigation to reduce such impacts. Examples of potential measures include the following:

• Installation of electric vehicle charging stations;

• Improve walkability design and pedestrian network;

• Increase transit accessibility and frequency by incorporating Bus Rapid Transit lines with permanent operational funding stream; and

• Limit parking supply and unbundle parking costs. Lower parking supply below ITE rates and separate parking costs from property costs.

AQ-5 In order to reduce energy consumption from future development, applications (e.g., electrical plans, improvement maps) submitted to the City shall include the installation of energy-efficient street lighting throughout the project site where street lighting is proposed.

5.3 CUMULATIVELY CONSIDERABLE NET INCREASE OF CRITERIA POLLUTANTS

As discussed previously, the proposed SYCPU is intended to further express General Plan policies in the proposed SYCPU area through the provision of site-specific recommendations that implement city-wide goals and policies, address community needs, and guide zoning. The two documents work together to establish the framework for growth and development in the proposed SYCPU area. The proposed SYCPU contains eight elements, each providing neighborhood-specific goals and recommendations. These goals and recommendations are consistent with development design guidelines, other mobility and civic guidelines, incentives, and programs in accordance with the general goals stated in the General Plan. Mitigation Measures AQ-1 through AQ-5 would reduce criteria pollutant emissions but the contribution of air pollutants to the SDAB would result in a significant cumulative impact on air quality with the SDAB which would be unavoidable.

Page 38: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 27

5.4 IMPACTS TO SENSITIVE RECEPTORS

5.4.1 Carbon Monoxide Hot Spots

The analysis indicated there would be the potential for a CO hot spot or exposure of sensitive receptors to substantial, project generated, local CO emissions. The impact would be potentially significant. While implementation of Mitigation Measures AQ-3 and AQ-4 would reduce construction and operations CO emissions, the ability of future development to successfully implement the actions required to fully meet these mitigation measures cannot be guaranteed at this time. Thus, CO hotspot impacts from construction and operation under the proposed SYCPU and SYHVSP are considered significant and unavoidable at the program level.

5.4.2 Diesel Particulate Matter

Sensitive uses located within the buffer distances of the facilities, indicated previously in Table 7, could be exposed to unacceptable DPM levels. Impacts would be significant. While implementation of Mitigation Measure AQ-6 would reduce DPM impacts, the ability of future development to successfully implement the actions required to fully meet DPM threshold cannot be guaranteed at this time. Thus, DPM impacts under the proposed SYCPU and SYHVSP are considered significant and unavoidable at the program-level.

AQ-6 Prior to the issuance of building permits for any facility within the buffer area identified in Table 7, a health risk assessment shall be prepared that demonstrates that health risks would be below the level of significance identified in Table 4.

5.5 ODORS

The SYCPU does not propose any specific new sources of odor that could affect sensitive receptors. Impacts associated with odors are anticipated to be less than significant.

Page 39: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 28

6.0 REFERENCES

California Air Resources Board (CARB). 2015a. Top 4 Measurements and Days Above the Standard. Available at: http://www.arb.ca.gov/adam/welcome.html. Accessed September 2015. 2015b. Federal Standard Area Designations. Available at:

http://www.arb.ca.gov/desig/feddesig.htm. Accessed September 2015. 2014. Area Designations and Maps – 2013. November. 2013. Ambient Air Quality Standards. Available at:

http://www.arb.ca.gov/research/aaqs/aaqs2.pdf. June. 2009. ARB Fact Sheet: Air Pollution and Health. December 2. Available at:

http://www.arb.ca.gov/research/health/fs/fs1/fs1.htm 2005. Air Quality and Land Use Handbook: A Community Health Perspective. April.

City of San Diego. 2011. California Environmental Quality Act Significance Determination

Thresholds. Development Services Department. ENVIRON. 2013. California Emissions Estimator Model User’s Guide Version 2013.2.2. July.

Available at: http://caleemod.com/ Iowa Environmental Mesonet. 2015. San Diego/Brown Field Windrose Plot. Available at:

http://mesonet.agron.iastate.edu/sites/windrose.phtml?station=SDM&network=CA_ASOS Kimley-Horn and Associates. 2015. San Ysidro CPU Traffic Impact Study. September. San Diego County Air Pollution Control District (SDAPCD). 2010. Fact Sheet: Attainment

Status. Available at: http://www.sdapcd.org/info/facts/attain.pdf. January. South Coast Air Quality Management District (SCAQMD). 2013. California Emission

Estimator Model (CalEEMod) Version 2013.2.2. Re-released September 2013. United States Environmental Protection Agency (USEPA). 2015a. Monitor Values Report.

http://www.epa.gov/airdata/ad_rep_mon.html. Accessed September 2015. 2015b. Final Area Designations and Classification. 2007. The Effects of Air Pollutants – Health Effects. Available at:

http://www.epa.gov/region7/air/quality/health.htm. Western Regional Climate Center, Western U.S. Climate Summaries, California, Chula Vista

(041758), 2015.

Page 40: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 29

7.0 LIST OF PREPARERS

Preparers: Victor Ortiz, Air Quality Specialist Joanne M. Dramko, AICP, Senior Air Quality Specialist, Quality Assurance Reviewer HELIX Environmental Planning, Inc. 7578 El Cajon Boulevard La Mesa, CA 91942

Page 41: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 30

THIS PAGE INTENTIONALLY LEFT BLANK

Page 42: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Appendix A

CALEEMOD EMISSION CALCULATIONS

Page 43: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

San Diego County, Winter

SYCPU - Existing (2010)

1.1 Land Usage

Land Uses Size Metric Lot Acreage Floor Surface Area Population

Bank (with Drive-Through) 17.70 1000sqft 0.41 17,700.00 0

General Office Building 7.00 1000sqft 0.16 7,000.00 0

Government (Civic Center) 12.90 1000sqft 0.30 12,900.00 0

Government Office Building 317.50 1000sqft 7.29 317,500.00 0

Medical Office Building 48.30 1000sqft 1.11 48,300.00 0

Elementary School 4,108.00 Student 7.88 343,442.64 0

High School 37.60 1000sqft 0.86 37,600.00 0

Junior College (2Yr) 2,300.00 Student 2.30 100,400.15 0

Junior High School 993.00 Student 2.68 116,738.75 0

Library 4.30 1000sqft 0.10 4,300.00 0

Place of Worship 175.50 1000sqft 4.03 175,500.00 0

General Light Industry 1,309.80 1000sqft 30.07 1,309,800.00 0

Industrial Park 46.90 1000sqft 1.08 46,900.00 0

Unrefrigerated Warehouse-No Rail 11.50 1000sqft 0.26 11,500.00 0

Enclosed Parking Structure 9.80 Acre 9.80 426,888.00 0

Parking Lot 7,987.00 Space 71.88 3,194,800.00 0

City Park 35.80 Acre 35.80 1,559,448.00 0

Fast Food Restaurant with Drive Thru 45.40 1000sqft 1.04 45,400.00 0

High Turnover (Sit Down Restaurant) 40.00 1000sqft 0.92 40,000.00 0

Hotel 756.00 Room 25.20 1,097,712.00 0

Motel 35.00 Room 1.57 68,607.00 0

1.0 Project Characteristics

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 1 of 17

Page 44: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Project Characteristics -

Land Use -

Construction Phase - No Construction

Vehicle Trips - Kimley Horn 2015

Energy Use -

Vechicle Emission Factors -

Vechicle Emission Factors -

Vechicle Emission Factors -

Condo/Townhouse 4,476.00 Dwelling Unit 279.75 4,476,000.00 12801

Mobile Home Park 532.00 Dwelling Unit 67.02 638,400.00 1522

Single Family Housing 2,339.00 Dwelling Unit 759.42 4,210,200.00 6690

Convenience Market (24 Hour) 2.70 1000sqft 0.06 2,700.00 0

Convenience Market With Gas Pumps 84.00 Pump 0.27 11,858.69 0

Regional Shopping Center 1,443.40 1000sqft 33.14 1,443,400.00 0

Strip Mall 507.20 1000sqft 11.64 507,200.00 0

Supermarket 23.00 1000sqft 0.53 23,000.00 0

1.2 Other Project Characteristics

Urbanization

Climate Zone

Urban

13

Wind Speed (m/s) Precipitation Freq (Days)2.6 40

1.3 User Entered Comments & Non-Default Data

Utility Company San Diego Gas & Electric

2010Operational Year

CO2 Intensity (lb/MWhr)

720.49 0.029CH4 Intensity (lb/MWhr)

0.006N2O Intensity (lb/MWhr)

Table Name Column Name Default Value New Value

tblConstructionPhase NumDays 10,000.00 0.00

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 2 of 17

Page 45: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

tblProjectCharacteristics OperationalYear 2014 2010

tblVehicleTrips ST_TR 86.32 182.43

tblVehicleTrips ST_TR 1.59 50.66

tblVehicleTrips ST_TR 7.16 6.51

tblVehicleTrips ST_TR 863.10 706.30

tblVehicleTrips ST_TR 204.47 150.23

tblVehicleTrips ST_TR 0.00 107.01

tblVehicleTrips ST_TR 722.03 699.22

tblVehicleTrips ST_TR 1.32 13.42

tblVehicleTrips ST_TR 2.37 25.14

tblVehicleTrips ST_TR 158.37 129.69

tblVehicleTrips ST_TR 8.19 10.03

tblVehicleTrips ST_TR 2.49 16.20

tblVehicleTrips ST_TR 46.55 49.87

tblVehicleTrips ST_TR 8.96 49.96

tblVehicleTrips ST_TR 5.00 4.97

tblVehicleTrips ST_TR 5.63 9.00

tblVehicleTrips ST_TR 0.00 2.26

tblVehicleTrips ST_TR 10.37 11.95

tblVehicleTrips ST_TR 49.97 42.21

tblVehicleTrips ST_TR 10.08 9.01

tblVehicleTrips ST_TR 42.04 76.34

tblVehicleTrips ST_TR 177.59 150.17

tblVehicleTrips ST_TR 2.59 5.10

tblVehicleTrips SU_TR 31.90 182.43

tblVehicleTrips SU_TR 1.59 50.66

tblVehicleTrips SU_TR 6.07 6.51

tblVehicleTrips SU_TR 758.45 706.30

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 3 of 17

Page 46: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

tblVehicleTrips SU_TR 166.88 150.23

tblVehicleTrips SU_TR 0.00 107.01

tblVehicleTrips SU_TR 542.72 699.22

tblVehicleTrips SU_TR 0.68 13.42

tblVehicleTrips SU_TR 0.98 25.14

tblVehicleTrips SU_TR 131.84 129.69

tblVehicleTrips SU_TR 5.95 10.03

tblVehicleTrips SU_TR 0.73 16.20

tblVehicleTrips SU_TR 25.49 49.87

tblVehicleTrips SU_TR 1.55 49.96

tblVehicleTrips SU_TR 4.36 4.97

tblVehicleTrips SU_TR 5.63 9.00

tblVehicleTrips SU_TR 0.00 2.26

tblVehicleTrips SU_TR 36.63 11.95

tblVehicleTrips SU_TR 25.24 42.21

tblVehicleTrips SU_TR 8.77 9.01

tblVehicleTrips SU_TR 20.43 76.34

tblVehicleTrips SU_TR 166.44 150.17

tblVehicleTrips SU_TR 2.59 5.10

tblVehicleTrips WD_TR 148.15 182.43

tblVehicleTrips WD_TR 1.59 50.66

tblVehicleTrips WD_TR 6.59 6.51

tblVehicleTrips WD_TR 737.99 706.30

tblVehicleTrips WD_TR 542.60 150.23

tblVehicleTrips WD_TR 1.29 2.91

tblVehicleTrips WD_TR 0.00 107.01

tblVehicleTrips WD_TR 496.12 699.22

tblVehicleTrips WD_TR 6.97 13.42

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 4 of 17

Page 47: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

2.0 Emissions Summary

tblVehicleTrips WD_TR 11.01 25.14

tblVehicleTrips WD_TR 27.92 29.83

tblVehicleTrips WD_TR 68.93 27.80

tblVehicleTrips WD_TR 12.89 18.00

tblVehicleTrips WD_TR 127.15 129.69

tblVehicleTrips WD_TR 8.17 10.03

tblVehicleTrips WD_TR 6.96 16.20

tblVehicleTrips WD_TR 1.20 1.66

tblVehicleTrips WD_TR 1.62 1.41

tblVehicleTrips WD_TR 56.24 49.87

tblVehicleTrips WD_TR 36.13 49.96

tblVehicleTrips WD_TR 4.99 4.97

tblVehicleTrips WD_TR 5.63 9.00

tblVehicleTrips WD_TR 0.00 2.26

tblVehicleTrips WD_TR 9.11 11.95

tblVehicleTrips WD_TR 42.94 42.21

tblVehicleTrips WD_TR 9.57 9.01

tblVehicleTrips WD_TR 44.32 76.34

tblVehicleTrips WD_TR 102.24 150.17

tblVehicleTrips WD_TR 2.59 5.10

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e

Percent Reduction

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 5 of 17

Page 48: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

2.2 Overall Operational

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Area 11,831.4268

160.3032 14,498.5435

5.4424 1,949.2036

1,949.2036

1,949.1466

1,949.1466 204,038.9057

86,666.8106

290,705.7163

189.6395 16.0492 299,663.3983

Energy 8.1813 71.9847 44.9455 0.4463 5.6525 5.6525 5.6525 5.6525 89,250.0781

89,250.0781

1.7106 1.6363 89,793.2392

Mobile 1,143.2180

2,151.5750

10,327.0950

15.3151 1,072.0762

29.1998 1,101.2760

286.1681 26.7951 312.9632 1,410,023.7551

1,410,023.7551

71.4988 1,411,525.2292

Total 12,982.8260

2,383.8629

24,870.5840

21.2037 1,072.0762

1,984.0559

3,056.1322

286.1681 1,981.5942

2,267.7622 204,038.9057

1,585,940.6438

1,789,979.5495

262.8489 17.6855 1,800,981.8667

Unmitigated Operational

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Area 11,831.4268

160.3032 14,498.5435

5.4424 1,949.2036

1,949.2036

1,949.1466

1,949.1466 204,038.9057

86,666.8106

290,705.7163

189.6395 16.0492 299,663.3983

Energy 8.1813 71.9847 44.9455 0.4463 5.6525 5.6525 5.6525 5.6525 89,250.0781

89,250.0781

1.7106 1.6363 89,793.2392

Mobile 1,143.2180

2,151.5750

10,327.0950

15.3151 1,072.0762

29.1998 1,101.2760

286.1681 26.7951 312.9632 1,410,023.7551

1,410,023.7551

71.4988 1,411,525.2292

Total 12,982.8260

2,383.8629

24,870.5840

21.2037 1,072.0762

1,984.0559

3,056.1322

286.1681 1,981.5942

2,267.7622 204,038.9057

1,585,940.6438

1,789,979.5495

262.8489 17.6855 1,800,981.8667

Mitigated Operational

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 6 of 17

Page 49: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.0 Construction Detail

3.1 Mitigation Measures Construction

Construction Phase

Phase Number

Phase Name Phase Type Start Date End Date Num Days Week

Num Days Phase Description

1 Demolition Demolition 1/1/2016 12/31/2015 5 0

OffRoad Equipment

Phase Name Offroad Equipment Type Amount Usage Hours Horse Power Load Factor

Demolition Concrete/Industrial Saws 1 8.00 81 0.73

Demolition Excavators 3 8.00 162 0.38

Demolition Rubber Tired Dozers 2 8.00 255 0.40

Trips and VMT

Phase Name Offroad Equipment Count

Worker Trip Number

Vendor Trip Number

Hauling Trip Number

Worker Trip Length

Vendor Trip Length

Hauling Trip Length

Worker Vehicle Class

Vendor Vehicle Class

Hauling Vehicle Class

Demolition 6 15.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e

Percent Reduction

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Residential Indoor: 0; Residential Outdoor: 0; Non-Residential Indoor: 0; Non-Residential Outdoor: 0 (Architectural Coating – sqft)

Acres of Grading (Site Preparation Phase): 0

Acres of Grading (Grading Phase): 0

Acres of Paving: 0

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 7 of 17

Page 50: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

4.0 Operational Detail - Mobile

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Unmitigated 1,143.2180

2,151.5750

10,327.0950

15.3151 1,072.0762

29.1998 1,101.2760

286.1681 26.7951 312.9632 1,410,023.7551

1,410,023.7551

71.4988 1,411,525.2292

Mitigated 1,143.2180

2,151.5750

10,327.0950

15.3151 1,072.0762

29.1998 1,101.2760

286.1681 26.7951 312.9632 1,410,023.7551

1,410,023.7551

71.4988 1,411,525.2292

4.1 Mitigation Measures Mobile

4.2 Trip Summary Information

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 8 of 17

Page 51: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

4.3 Trip Type Information

Average Daily Trip Rate Unmitigated Mitigated

Land Use Weekday Saturday Sunday Annual VMT Annual VMT

Bank (with Drive-Through) 3,229.01 3,229.01 3229.01 2,986,757 2,986,757

City Park 1,813.63 1,813.63 1813.63 3,871,829 3,871,829

Condo/Townhouse 29,138.76 29,138.76 29138.76 83,199,999 83,199,999

Convenience Market (24 Hour) 1,907.01 1,907.01 1907.01 1,452,335 1,452,335

Convenience Market With Gas Pumps 12,619.32 12,619.32 12619.32 6,769,057 6,769,057

Elementary School 11,954.28 0.00 0.00 18,827,471 18,827,471

Enclosed Parking Structure 0.00 0.00 0.00

Fast Food Restaurant with Drive Thru 31,744.59 31,744.59 31744.59 29,659,763 29,659,763

General Light Industry 17,577.52 17,577.52 17577.52 51,317,754 51,317,754

General Office Building 175.98 175.98 175.98 420,549 420,549

Government (Civic Center) 384.81 0.00 0.00 525,437 525,437

Government Office Building 8,826.50 0.00 0.00 10,811,709 10,811,709

High School 676.80 164.31 67.30 1,352,324 1,352,324

High Turnover (Sit Down Restaurant) 5,187.60 5,187.60 5187.60 6,018,988 6,018,988

Hotel 7,582.68 7,582.68 7582.68 14,406,567 14,406,567

Industrial Park 759.78 759.78 759.78 1,992,013 1,992,013

Junior College (2Yr) 3,818.00 966.00 92.00 7,309,513 7,309,513

Junior High School 1,400.13 0.00 0.00 2,248,403 2,248,403

Library 214.44 214.44 214.44 363,447 363,447

Medical Office Building 2,413.07 2,413.07 2413.07 4,722,977 4,722,977

Mobile Home Park 2,644.04 2,644.04 2644.04 7,549,536 7,549,536

Motel 315.00 315.00 315.00 597,797 597,797

Parking Lot 0.00 0.00 0.00

Place of Worship 2,097.23 2,097.23 2097.23 3,923,252 3,923,252

Regional Shopping Center 60,925.91 60,925.91 60925.91 106,821,699 106,821,699

Single Family Housing 21,074.39 21,074.39 21074.39 60,173,777 60,173,777

Strip Mall 38,719.65 38,719.65 38719.65 59,629,537 59,629,537

Supermarket 3,453.91 3,453.91 3453.91 3,928,628 3,928,628

Unrefrigerated Warehouse-No Rail 58.65 58.65 58.65 171,229 171,229

Total 270,712.68 244,782.47 243,811.46 491,052,345 491,052,345

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 9 of 17

Page 52: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Miles Trip % Trip Purpose %

Land Use H-W or C-W H-S or C-C H-O or C-NW H-W or C-W H-S or C-C H-O or C-NW Primary Diverted Pass-by

Bank (with Drive-Through) 9.50 7.30 7.30 6.60 74.40 19.00 27 26 47

City Park 9.50 7.30 7.30 33.00 48.00 19.00 66 28 6

Condo/Townhouse 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Convenience Market (24 Hour) 9.50 7.30 7.30 0.90 80.10 19.00 24 15 61

Convenience Market With Gas Pumps

9.50 7.30 7.30 0.80 80.20 19.00 14 21 65

Elementary School 9.50 7.30 7.30 65.00 30.00 5.00 63 25 12

Enclosed Parking Structure 9.50 7.30 7.30 0.00 0.00 0.00 0 0 0

Fast Food Restaurant with Drive Thru

9.50 7.30 7.30 2.20 78.80 19.00 29 21 50

General Light Industry 9.50 7.30 7.30 59.00 28.00 13.00 92 5 3

General Office Building 9.50 7.30 7.30 33.00 48.00 19.00 77 19 4

Government (Civic Center) 9.50 7.30 7.30 75.00 20.00 5.00 50 34 16

Government Office Building 9.50 7.30 7.30 33.00 62.00 5.00 50 34 16

High School 9.50 7.30 7.30 77.80 17.20 5.00 75 19 6

High Turnover (Sit Down Restaurant)

9.50 7.30 7.30 8.50 72.50 19.00 37 20 43

Hotel 9.50 7.30 7.30 19.40 61.60 19.00 58 38 4

Industrial Park 9.50 7.30 7.30 59.00 28.00 13.00 79 19 2

Junior College (2Yr) 9.50 7.30 7.30 6.40 88.60 5.00 92 7 1

Junior High School 9.50 7.30 7.30 72.80 22.20 5.00 63 25 12

Library 9.50 7.30 7.30 52.00 43.00 5.00 44 44 12

Medical Office Building 9.50 7.30 7.30 29.60 51.40 19.00 60 30 10

Mobile Home Park 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Motel 9.50 7.30 7.30 19.00 62.00 19.00 58 38 4

Parking Lot 9.50 7.30 7.30 0.00 0.00 0.00 0 0 0

Place of Worship 9.50 7.30 7.30 0.00 95.00 5.00 64 25 11

Regional Shopping Center 9.50 7.30 7.30 16.30 64.70 19.00 54 35 11

Single Family Housing 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Strip Mall 9.50 7.30 7.30 16.60 64.40 19.00 45 40 15

Supermarket 9.50 7.30 7.30 6.50 74.50 19.00 34 30 36

Unrefrigerated Warehouse-No Rail

9.50 7.30 7.30 59.00 0.00 41.00 92 5 3

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 10 of 17

Page 53: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

5.0 Energy Detail

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

NaturalGas Mitigated

8.1813 71.9847 44.9455 0.4463 5.6525 5.6525 5.6525 5.6525 89,250.0781

89,250.0781

1.7106 1.6363 89,793.2392

NaturalGas Unmitigated

8.1813 71.9847 44.9455 0.4463 5.6525 5.6525 5.6525 5.6525 89,250.0781

89,250.0781

1.7106 1.6363 89,793.2392

5.2 Energy by Land Use - NaturalGas

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Bank (with Drive-Through)

595.981 6.4300e-003

0.0584 0.0491 3.5000e-004

4.4400e-003

4.4400e-003

4.4400e-003

4.4400e-003

70.1154 70.1154 1.3400e-003

1.2900e-003

70.5421

City Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Unmitigated

5.1 Mitigation Measures Energy

4.4 Fleet Mix

LDA LDT1 LDT2 MDV LHD1 LHD2 MHD HHD OBUS UBUS MCY SBUS MH

0.509376 0.073655 0.192210 0.135105 0.037177 0.005354 0.012300 0.020284 0.001820 0.002092 0.006537 0.000620 0.003469

Historical Energy Use: Y

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 11 of 17

Page 54: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Condo/Townhouse

179079 1.9312 16.5033 7.0227 0.1053 1.3343 1.3343 1.3343 1.3343 21,068.0884

21,068.0884

0.4038 0.3863 21,196.3052

Convenience Market (24 Hour)

17.8274 1.9000e-004

1.7500e-003

1.4700e-003

1.0000e-005

1.3000e-004

1.3000e-004

1.3000e-004

1.3000e-004

2.0973 2.0973 4.0000e-005

4.0000e-005

2.1101

Convenience Market With Gas

Pumps

78.2998 8.4000e-004

7.6800e-003

6.4500e-003

5.0000e-005

5.8000e-004

5.8000e-004

5.8000e-004

5.8000e-004

9.2118 9.2118 1.8000e-004

1.7000e-004

9.2678

Elementary School

6473.66 0.0698 0.6347 0.5331 3.8100e-003

0.0482 0.0482 0.0482 0.0482 761.6069 761.6069 0.0146 0.0140 766.2419

Enclosed Parking Structure

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Fast Food Restaurant with

Drive Thru

21981.1 0.2371 2.1550 1.8102 0.0129 0.1638 0.1638 0.1638 0.1638 2,586.0074

2,586.0074

0.0496 0.0474 2,601.7454

General Light Industry

44102.6 0.4756 4.3238 3.6320 0.0259 0.3286 0.3286 0.3286 0.3286 5,188.5389

5,188.5389

0.0995 0.0951 5,220.1155

General Office Building

451.836 4.8700e-003

0.0443 0.0372 2.7000e-004

3.3700e-003

3.3700e-003

3.3700e-003

3.3700e-003

53.1571 53.1571 1.0200e-003

9.7000e-004

53.4806

Government (Civic Center)

832.668 8.9800e-003

0.0816 0.0686 4.9000e-004

6.2000e-003

6.2000e-003

6.2000e-003

6.2000e-003

97.9610 97.9610 1.8800e-003

1.8000e-003

98.5572

Government Office Building

20494 0.2210 2.0092 1.6877 0.0121 0.1527 0.1527 0.1527 0.1527 2,411.0556

2,411.0556

0.0462 0.0442 2,425.7289

High School 708.734 7.6400e-003

0.0695 0.0584 4.2000e-004

5.2800e-003

5.2800e-003

5.2800e-003

5.2800e-003

83.3805 83.3805 1.6000e-003

1.5300e-003

83.8879

High Turnover (Sit Down Restaurant)

19366.6 0.2089 1.8987 1.5949 0.0114 0.1443 0.1443 0.1443 0.1443 2,278.4206

2,278.4206

0.0437 0.0418 2,292.2867

Hotel 185228 1.9976 18.1596 15.2540 0.1090 1.3801 1.3801 1.3801 1.3801 21,791.4850

21,791.4850

0.4177 0.3995 21,924.1043

Industrial Park 3027.3 0.0327 0.2968 0.2493 1.7800e-003

0.0226 0.0226 0.0226 0.0226 356.1528 356.1528 6.8300e-003

6.5300e-003

358.3203

Junior College (2Yr)

11346.6 0.1224 1.1124 0.9344 6.6700e-003

0.0845 0.0845 0.0845 0.0845 1,334.8932

1,334.8932

0.0256 0.0245 1,343.0172

Junior High School

2200.45 0.0237 0.2157 0.1812 1.2900e-003

0.0164 0.0164 0.0164 0.0164 258.8759 258.8759 4.9600e-003

4.7500e-003

260.4514

Library 144.786 1.5600e-003

0.0142 0.0119 9.0000e-005

1.0800e-003

1.0800e-003

1.0800e-003

1.0800e-003

17.0337 17.0337 3.3000e-004

3.1000e-004

17.1374

Medical Office Building

3117.67 0.0336 0.3057 0.2568 1.8300e-003

0.0232 0.0232 0.0232 0.0232 366.7842 366.7842 7.0300e-003

6.7200e-003

369.0164

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 12 of 17

Page 55: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Mobile Home Park

34532.3 0.3724 3.1824 1.3542 0.0203 0.2573 0.2573 0.2573 0.2573 4,062.6246

4,062.6246

0.0779 0.0745 4,087.3491

Motel 11576.7 0.1249 1.1350 0.9534 6.8100e-003

0.0863 0.0863 0.0863 0.0863 1,361.9678

1,361.9678

0.0261 0.0250 1,370.2565

Parking Lot 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Place of Worship 5909.3 0.0637 0.5793 0.4867 3.4800e-003

0.0440 0.0440 0.0440 0.0440 695.2119 695.2119 0.0133 0.0128 699.4429

Regional Shopping Center

9530.39 0.1028 0.9344 0.7849 5.6100e-003

0.0710 0.0710 0.0710 0.0710 1,121.2229

1,121.2229

0.0215 0.0206 1,128.0465

Single Family Housing

192756 2.0787 17.7638 7.5591 0.1134 1.4362 1.4362 1.4362 1.4362 22,677.2176

22,677.2176

0.4347 0.4158 22,815.2273

Strip Mall 3348.91 0.0361 0.3283 0.2758 1.9700e-003

0.0250 0.0250 0.0250 0.0250 393.9894 393.9894 7.5500e-003

7.2200e-003

396.3871

Supermarket 1661.67 0.0179 0.1629 0.1368 9.8000e-004

0.0124 0.0124 0.0124 0.0124 195.4907 195.4907 3.7500e-003

3.5800e-003

196.6805

Unrefrigerated Warehouse-No

Rail

63.6438 6.9000e-004

6.2400e-003

5.2400e-003

4.0000e-005

4.7000e-004

4.7000e-004

4.7000e-004

4.7000e-004

7.4875 7.4875 1.4000e-004

1.4000e-004

7.5331

Total 8.1813 71.9846 44.9455 0.4463 5.6525 5.6525 5.6525 5.6525 89,250.0781

89,250.0781

1.7107 1.6363 89,793.2392

5.2 Energy by Land Use - NaturalGas

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

City Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Condo/Townhouse

179.079 1.9312 16.5033 7.0227 0.1053 1.3343 1.3343 1.3343 1.3343 21,068.0884

21,068.0884

0.4038 0.3863 21,196.3052

Convenience Market (24 Hour)

0.0178274 1.9000e-004

1.7500e-003

1.4700e-003

1.0000e-005

1.3000e-004

1.3000e-004

1.3000e-004

1.3000e-004

2.0973 2.0973 4.0000e-005

4.0000e-005

2.1101

Mitigated

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 13 of 17

Page 56: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Convenience Market With Gas

Pumps

0.0782998 8.4000e-004

7.6800e-003

6.4500e-003

5.0000e-005

5.8000e-004

5.8000e-004

5.8000e-004

5.8000e-004

9.2118 9.2118 1.8000e-004

1.7000e-004

9.2678

Elementary School

6.47366 0.0698 0.6347 0.5331 3.8100e-003

0.0482 0.0482 0.0482 0.0482 761.6069 761.6069 0.0146 0.0140 766.2419

Enclosed Parking Structure

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Bank (with Drive-Through)

0.595981 6.4300e-003

0.0584 0.0491 3.5000e-004

4.4400e-003

4.4400e-003

4.4400e-003

4.4400e-003

70.1154 70.1154 1.3400e-003

1.2900e-003

70.5421

Fast Food Restaurant with

Drive Thru

21.9811 0.2371 2.1550 1.8102 0.0129 0.1638 0.1638 0.1638 0.1638 2,586.0074

2,586.0074

0.0496 0.0474 2,601.7454

General Light Industry

44.1026 0.4756 4.3238 3.6320 0.0259 0.3286 0.3286 0.3286 0.3286 5,188.5389

5,188.5389

0.0995 0.0951 5,220.1155

General Office Building

0.451836 4.8700e-003

0.0443 0.0372 2.7000e-004

3.3700e-003

3.3700e-003

3.3700e-003

3.3700e-003

53.1571 53.1571 1.0200e-003

9.7000e-004

53.4806

Government (Civic Center)

0.832668 8.9800e-003

0.0816 0.0686 4.9000e-004

6.2000e-003

6.2000e-003

6.2000e-003

6.2000e-003

97.9610 97.9610 1.8800e-003

1.8000e-003

98.5572

Government Office Building

20.494 0.2210 2.0092 1.6877 0.0121 0.1527 0.1527 0.1527 0.1527 2,411.0556

2,411.0556

0.0462 0.0442 2,425.7289

High School 0.708734 7.6400e-003

0.0695 0.0584 4.2000e-004

5.2800e-003

5.2800e-003

5.2800e-003

5.2800e-003

83.3805 83.3805 1.6000e-003

1.5300e-003

83.8879

High Turnover (Sit Down Restaurant)

19.3666 0.2089 1.8987 1.5949 0.0114 0.1443 0.1443 0.1443 0.1443 2,278.4206

2,278.4206

0.0437 0.0418 2,292.2867

Hotel 185.228 1.9976 18.1596 15.2540 0.1090 1.3801 1.3801 1.3801 1.3801 21,791.4850

21,791.4850

0.4177 0.3995 21,924.1043

Industrial Park 3.0273 0.0327 0.2968 0.2493 1.7800e-003

0.0226 0.0226 0.0226 0.0226 356.1528 356.1528 6.8300e-003

6.5300e-003

358.3203

Junior College (2Yr)

11.3466 0.1224 1.1124 0.9344 6.6700e-003

0.0845 0.0845 0.0845 0.0845 1,334.8932

1,334.8932

0.0256 0.0245 1,343.0172

Junior High School

2.20045 0.0237 0.2157 0.1812 1.2900e-003

0.0164 0.0164 0.0164 0.0164 258.8759 258.8759 4.9600e-003

4.7500e-003

260.4514

Library 0.144786 1.5600e-003

0.0142 0.0119 9.0000e-005

1.0800e-003

1.0800e-003

1.0800e-003

1.0800e-003

17.0337 17.0337 3.3000e-004

3.1000e-004

17.1374

Medical Office Building

3.11767 0.0336 0.3057 0.2568 1.8300e-003

0.0232 0.0232 0.0232 0.0232 366.7842 366.7842 7.0300e-003

6.7200e-003

369.0164

Mobile Home Park

34.5323 0.3724 3.1824 1.3542 0.0203 0.2573 0.2573 0.2573 0.2573 4,062.6246

4,062.6246

0.0779 0.0745 4,087.3491

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 14 of 17

Page 57: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

6.1 Mitigation Measures Area

6.0 Area Detail

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Motel 11.5767 0.1249 1.1350 0.9534 6.8100e-003

0.0863 0.0863 0.0863 0.0863 1,361.9678

1,361.9678

0.0261 0.0250 1,370.2565

Parking Lot 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Place of Worship 5.9093 0.0637 0.5793 0.4867 3.4800e-003

0.0440 0.0440 0.0440 0.0440 695.2119 695.2119 0.0133 0.0128 699.4429

Regional Shopping Center

9.53039 0.1028 0.9344 0.7849 5.6100e-003

0.0710 0.0710 0.0710 0.0710 1,121.2229

1,121.2229

0.0215 0.0206 1,128.0465

Single Family Housing

192.756 2.0787 17.7638 7.5591 0.1134 1.4362 1.4362 1.4362 1.4362 22,677.2176

22,677.2176

0.4347 0.4158 22,815.2273

Strip Mall 3.34891 0.0361 0.3283 0.2758 1.9700e-003

0.0250 0.0250 0.0250 0.0250 393.9894 393.9894 7.5500e-003

7.2200e-003

396.3871

Supermarket 1.66167 0.0179 0.1629 0.1368 9.8000e-004

0.0124 0.0124 0.0124 0.0124 195.4907 195.4907 3.7500e-003

3.5800e-003

196.6805

Unrefrigerated Warehouse-No

Rail

0.0636438 6.9000e-004

6.2400e-003

5.2400e-003

4.0000e-005

4.7000e-004

4.7000e-004

4.7000e-004

4.7000e-004

7.4875 7.4875 1.4000e-004

1.4000e-004

7.5331

Total 8.1813 71.9846 44.9455 0.4463 5.6525 5.6525 5.6525 5.6525 89,250.0781

89,250.0781

1.7107 1.6363 89,793.2392

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 15 of 17

Page 58: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Unmitigated 11,831.4268

160.3032 14,498.5435

5.4424 1,949.2036

1,949.2036

1,949.1466

1,949.1466 204,038.9057

86,666.8106

290,705.7163

189.6395 16.0492 299,663.3983

Mitigated 11,831.4268

160.3032 14,498.5435

5.4424 1,949.2036

1,949.2036

1,949.1466

1,949.1466 204,038.9057

86,666.8106

290,705.7163

189.6395 16.0492 299,663.3983

6.2 Area by SubCategory

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

SubCategory lb/day lb/day

Architectural Coating

129.9060 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Consumer Products

434.3172 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hearth 11,243.8118

152.5485 13,851.1686

5.4103 1,946.0052

1,946.0052

1,945.9481

1,945.9481 204,038.9057

85,570.9412

289,609.8469

188.2941 16.0492 298,539.2739

Landscaping 23.3917 7.7548 647.3749 0.0322 3.1984 3.1984 3.1984 3.1984 1,095.8694

1,095.8694

1.3455 1,124.1244

Total 11,831.4268

160.3032 14,498.5435

5.4424 1,949.2036

1,949.2036

1,949.1466

1,949.1466 204,038.9057

86,666.8106

290,705.7163

189.6395 16.0492 299,663.3983

Unmitigated

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 16 of 17

Page 59: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

8.1 Mitigation Measures Waste

7.1 Mitigation Measures Water

7.0 Water Detail

8.0 Waste Detail

10.0 Vegetation

6.2 Area by SubCategory

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

SubCategory lb/day lb/day

Architectural Coating

129.9060 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Consumer Products

434.3172 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hearth 11,243.8118

152.5485 13,851.1686

5.4103 1,946.0052

1,946.0052

1,945.9481

1,945.9481 204,038.9057

85,570.9412

289,609.8469

188.2941 16.0492 298,539.2739

Landscaping 23.3917 7.7548 647.3749 0.0322 3.1984 3.1984 3.1984 3.1984 1,095.8694

1,095.8694

1.3455 1,124.1244

Total 11,831.4268

160.3032 14,498.5435

5.4424 1,949.2036

1,949.2036

1,949.1466

1,949.1466 204,038.9057

86,666.8106

290,705.7163

189.6395 16.0492 299,663.3983

Mitigated

9.0 Operational Offroad

Equipment Type Number Hours/Day Days/Year Horse Power Load Factor Fuel Type

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/23/2015 1:36 PMPage 17 of 17

Page 60: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

San Diego County, Winter

SYCPU - No Change Proposed (2020)

1.1 Land Usage

Land Uses Size Metric Lot Acreage Floor Surface Area Population

Bank (with Drive-Through) 11.50 1000sqft 0.26 11,500.00 0

General Office Building 7.00 1000sqft 0.16 7,000.00 0

Government (Civic Center) 6.00 1000sqft 0.14 6,000.00 0

Government Office Building 317.50 1000sqft 7.29 317,500.00 0

Medical Office Building 48.30 1000sqft 1.11 48,300.00 0

Elementary School 4,108.00 Student 7.88 343,442.64 0

High School 37.60 1000sqft 0.86 37,600.00 0

Junior College (2Yr) 2,300.00 Student 2.30 100,400.15 0

Junior High School 993.00 Student 2.68 116,738.75 0

Library 4.30 1000sqft 0.10 4,300.00 0

Place of Worship 175.50 1000sqft 4.03 175,500.00 0

General Light Industry 1,281.50 1000sqft 29.42 1,281,500.00 0

Industrial Park 46.90 1000sqft 1.08 46,900.00 0

Unrefrigerated Warehouse-No Rail 11.50 1000sqft 0.26 11,500.00 0

Enclosed Parking Structure 6.70 Acre 6.70 291,852.00 0

Parking Lot 7,987.00 Space 71.88 3,194,800.00 0

City Park 35.80 Acre 35.80 1,559,448.00 0

Fast Food Restaurant with Drive Thru 44.90 1000sqft 1.03 44,900.00 0

High Turnover (Sit Down Restaurant) 22.40 1000sqft 0.51 22,400.00 0

Hotel 756.00 Room 25.20 1,097,712.00 0

Motel 35.00 Room 1.57 68,607.00 0

1.0 Project Characteristics

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 1 of 18

Page 61: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Condo/Townhouse 4,476.00 Dwelling Unit 279.75 4,476,000.00 12801

Mobile Home Park 419.00 Dwelling Unit 52.78 502,800.00 1198

Single Family Housing 2,183.00 Dwelling Unit 708.77 3,929,400.00 6243

Convenience Market (24 Hour) 0.00 1000sqft 0.00 0.00 0

Convenience Market With Gas Pumps 84.00 Pump 0.27 11,858.69 0

Regional Shopping Center 1,443.40 1000sqft 33.14 1,443,400.00 0

Strip Mall 507.20 1000sqft 11.64 507,200.00 0

Supermarket 0.00 1000sqft 0.00 0.00 0

1.2 Other Project Characteristics

Urbanization

Climate Zone

Urban

13

Wind Speed (m/s) Precipitation Freq (Days)2.6 40

1.3 User Entered Comments & Non-Default Data

Utility Company San Diego Gas & Electric

2020Operational Year

CO2 Intensity (lb/MWhr)

720.49 0.029CH4 Intensity (lb/MWhr)

0.006N2O Intensity (lb/MWhr)

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 2 of 18

Page 62: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Project Characteristics -

Land Use -

Construction Phase - No construction for existing

Vehicle Trips - Kimley Horn 2015

Vechicle Emission Factors -

Vechicle Emission Factors -

Vechicle Emission Factors -

Energy Use -

Energy Mitigation -

Water Mitigation -

Waste Mitigation -

Table Name Column Name Default Value New Value

tblConstructionPhase NumDays 10,000.00 0.00

tblProjectCharacteristics OperationalYear 2014 2020

tblVehicleTrips CC_TTP 0.00 80.20

tblVehicleTrips CC_TTP 0.00 80.20

tblVehicleTrips CNW_TTP 0.00 19.00

tblVehicleTrips CNW_TTP 0.00 19.00

tblVehicleTrips CW_TTP 0.00 0.80

tblVehicleTrips CW_TTP 0.00 0.80

tblVehicleTrips PR_TP 0.00 100.00

tblVehicleTrips PR_TP 0.00 100.00

tblVehicleTrips ST_TR 86.32 200.26

tblVehicleTrips ST_TR 1.59 50.66

tblVehicleTrips ST_TR 7.16 6.51

tblVehicleTrips ST_TR 863.10 706.30

tblVehicleTrips ST_TR 204.47 150.23

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 3 of 18

Page 63: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

tblVehicleTrips ST_TR 0.00 107.01

tblVehicleTrips ST_TR 722.03 699.22

tblVehicleTrips ST_TR 1.32 13.42

tblVehicleTrips ST_TR 2.37 25.14

tblVehicleTrips ST_TR 158.37 129.69

tblVehicleTrips ST_TR 8.19 10.03

tblVehicleTrips ST_TR 2.49 16.20

tblVehicleTrips ST_TR 46.55 49.87

tblVehicleTrips ST_TR 8.96 49.96

tblVehicleTrips ST_TR 5.00 4.97

tblVehicleTrips ST_TR 5.63 9.00

tblVehicleTrips ST_TR 0.00 2.26

tblVehicleTrips ST_TR 10.37 11.95

tblVehicleTrips ST_TR 49.97 42.21

tblVehicleTrips ST_TR 10.08 9.01

tblVehicleTrips ST_TR 42.04 93.10

tblVehicleTrips ST_TR 177.59 150.17

tblVehicleTrips ST_TR 2.59 5.10

tblVehicleTrips SU_TR 31.90 200.26

tblVehicleTrips SU_TR 1.59 50.66

tblVehicleTrips SU_TR 6.07 6.51

tblVehicleTrips SU_TR 758.45 706.30

tblVehicleTrips SU_TR 166.88 150.23

tblVehicleTrips SU_TR 0.00 107.01

tblVehicleTrips SU_TR 542.72 699.22

tblVehicleTrips SU_TR 0.68 13.42

tblVehicleTrips SU_TR 0.98 25.14

tblVehicleTrips SU_TR 131.84 129.69

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 4 of 18

Page 64: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

tblVehicleTrips SU_TR 5.95 10.03

tblVehicleTrips SU_TR 0.73 16.20

tblVehicleTrips SU_TR 25.49 49.87

tblVehicleTrips SU_TR 1.55 49.96

tblVehicleTrips SU_TR 4.36 4.97

tblVehicleTrips SU_TR 5.63 9.00

tblVehicleTrips SU_TR 0.00 2.26

tblVehicleTrips SU_TR 36.63 11.95

tblVehicleTrips SU_TR 25.24 42.21

tblVehicleTrips SU_TR 8.77 9.01

tblVehicleTrips SU_TR 20.43 93.10

tblVehicleTrips SU_TR 166.44 150.17

tblVehicleTrips SU_TR 2.59 5.10

tblVehicleTrips WD_TR 148.15 200.26

tblVehicleTrips WD_TR 1.59 50.66

tblVehicleTrips WD_TR 6.59 6.51

tblVehicleTrips WD_TR 737.99 706.30

tblVehicleTrips WD_TR 542.60 150.23

tblVehicleTrips WD_TR 1.29 2.91

tblVehicleTrips WD_TR 0.00 107.01

tblVehicleTrips WD_TR 496.12 699.22

tblVehicleTrips WD_TR 6.97 13.42

tblVehicleTrips WD_TR 11.01 25.14

tblVehicleTrips WD_TR 27.92 29.83

tblVehicleTrips WD_TR 68.93 27.80

tblVehicleTrips WD_TR 12.89 18.00

tblVehicleTrips WD_TR 127.15 129.69

tblVehicleTrips WD_TR 8.17 10.03

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 5 of 18

Page 65: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

2.0 Emissions Summary

tblVehicleTrips WD_TR 6.96 16.20

tblVehicleTrips WD_TR 1.20 1.66

tblVehicleTrips WD_TR 1.62 1.41

tblVehicleTrips WD_TR 56.24 49.87

tblVehicleTrips WD_TR 36.13 49.96

tblVehicleTrips WD_TR 4.99 4.97

tblVehicleTrips WD_TR 5.63 9.00

tblVehicleTrips WD_TR 0.00 2.26

tblVehicleTrips WD_TR 9.11 11.95

tblVehicleTrips WD_TR 42.94 42.21

tblVehicleTrips WD_TR 9.57 9.01

tblVehicleTrips WD_TR 44.32 93.10

tblVehicleTrips WD_TR 102.24 150.17

tblVehicleTrips WD_TR 2.59 5.10

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e

Percent Reduction

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 6 of 18

Page 66: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

2.2 Overall Operational

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Area 11,395.8039

153.7586 13,931.9957

5.2432 1,877.9840

1,877.9840

1,877.9291

1,877.9291 196,568.3101

83,493.7721

280,062.0823

182.4371 15.4616 288,686.3515

Energy 7.8336 68.9426 43.1613 0.4273 5.4123 5.4123 5.4123 5.4123 85,457.0546

85,457.0546

1.6379 1.5667 85,977.1320

Mobile 818.3196 1,393.0358

7,165.6295

16.7200 1,171.2566

19.8708 1,191.1274

312.6475 18.3372 330.9847 1,278,929.0841

1,278,929.0841

51.4116 1,280,008.7271

Total 12,221.9570

1,615.7370

21,140.7865

22.3904 1,171.2566

1,903.2671

3,074.5237

312.6475 1,901.6785

2,214.3260 196,568.3101

1,447,879.9109

1,644,448.2210

235.4866 17.0283 1,654,672.2106

Unmitigated Operational

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Area 11,395.8039

153.7586 13,931.9957

5.2432 1,877.9840

1,877.9840

1,877.9291

1,877.9291 196,568.3101

83,493.7721

280,062.0823

182.4371 15.4616 288,686.3515

Energy 7.8336 68.9426 43.1613 0.4273 5.4123 5.4123 5.4123 5.4123 85,457.0546

85,457.0546

1.6379 1.5667 85,977.1320

Mobile 818.3196 1,393.0358

7,165.6295

16.7200 1,171.2566

19.8708 1,191.1274

312.6475 18.3372 330.9847 1,278,929.0841

1,278,929.0841

51.4116 1,280,008.7271

Total 12,221.9570

1,615.7370

21,140.7865

22.3904 1,171.2566

1,903.2671

3,074.5237

312.6475 1,901.6785

2,214.3260 196,568.3101

1,447,879.9109

1,644,448.2210

235.4866 17.0283 1,654,672.2106

Mitigated Operational

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 7 of 18

Page 67: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.0 Construction Detail

3.1 Mitigation Measures Construction

Construction Phase

Phase Number

Phase Name Phase Type Start Date End Date Num Days Week

Num Days Phase Description

1 Demolition Demolition 1/1/2016 12/31/2015 5 0

OffRoad Equipment

Phase Name Offroad Equipment Type Amount Usage Hours Horse Power Load Factor

Demolition Concrete/Industrial Saws 1 8.00 81 0.73

Demolition Excavators 3 8.00 162 0.38

Demolition Rubber Tired Dozers 2 8.00 255 0.40

Trips and VMT

Phase Name Offroad Equipment Count

Worker Trip Number

Vendor Trip Number

Hauling Trip Number

Worker Trip Length

Vendor Trip Length

Hauling Trip Length

Worker Vehicle Class

Vendor Vehicle Class

Hauling Vehicle Class

Demolition 6 15.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e

Percent Reduction

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Residential Indoor: 0; Residential Outdoor: 0; Non-Residential Indoor: 0; Non-Residential Outdoor: 0 (Architectural Coating – sqft)

Acres of Grading (Site Preparation Phase): 0

Acres of Grading (Grading Phase): 0

Acres of Paving: 0

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 8 of 18

Page 68: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

4.0 Operational Detail - Mobile

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Unmitigated 818.3196 1,393.0358

7,165.6295

16.7200 1,171.2566

19.8708 1,191.1274

312.6475 18.3372 330.9847 1,278,929.0841

1,278,929.0841

51.4116 1,280,008.7271

Mitigated 818.3196 1,393.0358

7,165.6295

16.7200 1,171.2566

19.8708 1,191.1274

312.6475 18.3372 330.9847 1,278,929.0841

1,278,929.0841

51.4116 1,280,008.7271

4.1 Mitigation Measures Mobile

4.2 Trip Summary Information

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 9 of 18

Page 69: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

4.3 Trip Type Information

Average Daily Trip Rate Unmitigated Mitigated

Land Use Weekday Saturday Sunday Annual VMT Annual VMT

Bank (with Drive-Through) 2,302.99 2,302.99 2302.99 2,130,210 2,130,210

City Park 1,813.63 1,813.63 1813.63 3,871,829 3,871,829

Condo/Townhouse 29,138.76 29,138.76 29138.76 83,199,999 83,199,999

Convenience Market (24 Hour) 0.00 0.00 0.00

Convenience Market With Gas Pumps 12,619.32 12,619.32 12619.32 6,769,057 6,769,057

Elementary School 11,954.28 0.00 0.00 18,827,471 18,827,471

Enclosed Parking Structure 716.97 716.97 716.97 1,909,718 1,909,718

Fast Food Restaurant with Drive Thru 31,394.98 31,394.98 31394.98 29,333,114 29,333,114

General Light Industry 17,197.73 17,197.73 17197.73 50,208,964 50,208,964

General Office Building 175.98 175.98 175.98 420,549 420,549

Government (Civic Center) 178.98 0.00 0.00 244,389 244,389

Government Office Building 8,826.50 0.00 0.00 10,811,709 10,811,709

High School 676.80 164.31 67.30 1,352,324 1,352,324

High Turnover (Sit Down Restaurant) 2,905.06 2,905.06 2905.06 3,370,634 3,370,634

Hotel 7,582.68 7,582.68 7582.68 14,406,567 14,406,567

Industrial Park 759.78 759.78 759.78 1,992,013 1,992,013

Junior College (2Yr) 3,818.00 966.00 92.00 7,309,513 7,309,513

Junior High School 1,400.13 0.00 0.00 2,248,403 2,248,403

Library 214.44 214.44 214.44 363,447 363,447

Medical Office Building 2,413.07 2,413.07 2413.07 4,722,977 4,722,977

Mobile Home Park 2,082.43 2,082.43 2082.43 5,945,969 5,945,969

Motel 315.00 315.00 315.00 597,797 597,797

Parking Lot 18,050.62 18,050.62 18050.62 48,079,747 48,079,747

Place of Worship 2,097.23 2,097.23 2097.23 3,923,252 3,923,252

Regional Shopping Center 60,925.91 60,925.91 60925.91 106,821,699 106,821,699

Single Family Housing 19,668.83 19,668.83 19668.83 56,160,476 56,160,476

Strip Mall 47,220.32 47,220.32 47220.32 72,720,853 72,720,853

Supermarket 0.00 0.00 0.00

Unrefrigerated Warehouse-No Rail 58.65 58.65 58.65 171,229 171,229

Total 286,509.06 260,784.68 259,813.67 537,913,907 537,913,907

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 10 of 18

Page 70: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Miles Trip % Trip Purpose %

Land Use H-W or C-W H-S or C-C H-O or C-NW H-W or C-W H-S or C-C H-O or C-NW Primary Diverted Pass-by

Bank (with Drive-Through) 9.50 7.30 7.30 6.60 74.40 19.00 27 26 47

City Park 9.50 7.30 7.30 33.00 48.00 19.00 66 28 6

Condo/Townhouse 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Convenience Market (24 Hour) 9.50 7.30 7.30 0.90 80.10 19.00 24 15 61

Convenience Market With Gas Pumps

9.50 7.30 7.30 0.80 80.20 19.00 14 21 65

Elementary School 9.50 7.30 7.30 65.00 30.00 5.00 63 25 12

Enclosed Parking Structure 9.50 7.30 7.30 0.80 80.20 19.00 100 0 0

Fast Food Restaurant with Drive Thru

9.50 7.30 7.30 2.20 78.80 19.00 29 21 50

General Light Industry 9.50 7.30 7.30 59.00 28.00 13.00 92 5 3

General Office Building 9.50 7.30 7.30 33.00 48.00 19.00 77 19 4

Government (Civic Center) 9.50 7.30 7.30 75.00 20.00 5.00 50 34 16

Government Office Building 9.50 7.30 7.30 33.00 62.00 5.00 50 34 16

High School 9.50 7.30 7.30 77.80 17.20 5.00 75 19 6

High Turnover (Sit Down Restaurant)

9.50 7.30 7.30 8.50 72.50 19.00 37 20 43

Hotel 9.50 7.30 7.30 19.40 61.60 19.00 58 38 4

Industrial Park 9.50 7.30 7.30 59.00 28.00 13.00 79 19 2

Junior College (2Yr) 9.50 7.30 7.30 6.40 88.60 5.00 92 7 1

Junior High School 9.50 7.30 7.30 72.80 22.20 5.00 63 25 12

Library 9.50 7.30 7.30 52.00 43.00 5.00 44 44 12

Medical Office Building 9.50 7.30 7.30 29.60 51.40 19.00 60 30 10

Mobile Home Park 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Motel 9.50 7.30 7.30 19.00 62.00 19.00 58 38 4

Parking Lot 9.50 7.30 7.30 0.80 80.20 19.00 100 0 0

Place of Worship 9.50 7.30 7.30 0.00 95.00 5.00 64 25 11

Regional Shopping Center 9.50 7.30 7.30 16.30 64.70 19.00 54 35 11

Single Family Housing 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Strip Mall 9.50 7.30 7.30 16.60 64.40 19.00 45 40 15

Supermarket 9.50 7.30 7.30 6.50 74.50 19.00 34 30 36

Unrefrigerated Warehouse-No Rail

9.50 7.30 7.30 59.00 0.00 41.00 92 5 3

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 11 of 18

Page 71: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

5.0 Energy Detail

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

NaturalGas Mitigated

7.8336 68.9426 43.1613 0.4273 5.4123 5.4123 5.4123 5.4123 85,457.0546

85,457.0546

1.6379 1.5667 85,977.1320

NaturalGas Unmitigated

7.8336 68.9426 43.1613 0.4273 5.4123 5.4123 5.4123 5.4123 85,457.0546

85,457.0546

1.6379 1.5667 85,977.1320

5.2 Energy by Land Use - NaturalGas

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Bank (with Drive-Through)

387.219 4.1800e-003

0.0380 0.0319 2.3000e-004

2.8900e-003

2.8900e-003

2.8900e-003

2.8900e-003

45.5552 45.5552 8.7000e-004

8.4000e-004

45.8324

City Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Unmitigated

5.1 Mitigation Measures Energy

4.4 Fleet Mix

LDA LDT1 LDT2 MDV LHD1 LHD2 MHD HHD OBUS UBUS MCY SBUS MH

0.513300 0.073549 0.191092 0.130830 0.036094 0.005140 0.012550 0.022916 0.001871 0.002062 0.006564 0.000586 0.003446

Historical Energy Use: Y

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 12 of 18

Page 72: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Condo/Townhouse

179079 1.9312 16.5033 7.0227 0.1053 1.3343 1.3343 1.3343 1.3343 21,068.0884

21,068.0884

0.4038 0.3863 21,196.3052

Convenience Market (24 Hour)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Convenience Market With Gas

Pumps

78.2998 8.4000e-004

7.6800e-003

6.4500e-003

5.0000e-005

5.8000e-004

5.8000e-004

5.8000e-004

5.8000e-004

9.2118 9.2118 1.8000e-004

1.7000e-004

9.2678

Elementary School

6473.66 0.0698 0.6347 0.5331 3.8100e-003

0.0482 0.0482 0.0482 0.0482 761.6069 761.6069 0.0146 0.0140 766.2419

Enclosed Parking Structure

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Fast Food Restaurant with

Drive Thru

21739 0.2344 2.1313 1.7903 0.0128 0.1620 0.1620 0.1620 0.1620 2,557.5272

2,557.5272

0.0490 0.0469 2,573.0918

General Light Industry

43149.7 0.4653 4.2304 3.5535 0.0254 0.3215 0.3215 0.3215 0.3215 5,076.4335

5,076.4335

0.0973 0.0931 5,107.3279

General Office Building

451.836 4.8700e-003

0.0443 0.0372 2.7000e-004

3.3700e-003

3.3700e-003

3.3700e-003

3.3700e-003

53.1571 53.1571 1.0200e-003

9.7000e-004

53.4806

Government (Civic Center)

387.288 4.1800e-003

0.0380 0.0319 2.3000e-004

2.8900e-003

2.8900e-003

2.8900e-003

2.8900e-003

45.5633 45.5633 8.7000e-004

8.4000e-004

45.8406

Government Office Building

20494 0.2210 2.0092 1.6877 0.0121 0.1527 0.1527 0.1527 0.1527 2,411.0556

2,411.0556

0.0462 0.0442 2,425.7289

High School 708.734 7.6400e-003

0.0695 0.0584 4.2000e-004

5.2800e-003

5.2800e-003

5.2800e-003

5.2800e-003

83.3805 83.3805 1.6000e-003

1.5300e-003

83.8879

High Turnover (Sit Down Restaurant)

10845.3 0.1170 1.0633 0.8931 6.3800e-003

0.0808 0.0808 0.0808 0.0808 1,275.9156

1,275.9156

0.0245 0.0234 1,283.6806

Hotel 185228 1.9976 18.1596 15.2540 0.1090 1.3801 1.3801 1.3801 1.3801 21,791.4850

21,791.4850

0.4177 0.3995 21,924.1043

Industrial Park 3027.3 0.0327 0.2968 0.2493 1.7800e-003

0.0226 0.0226 0.0226 0.0226 356.1528 356.1528 6.8300e-003

6.5300e-003

358.3203

Junior College (2Yr)

11346.6 0.1224 1.1124 0.9344 6.6700e-003

0.0845 0.0845 0.0845 0.0845 1,334.8932

1,334.8932

0.0256 0.0245 1,343.0172

Junior High School

2200.45 0.0237 0.2157 0.1812 1.2900e-003

0.0164 0.0164 0.0164 0.0164 258.8759 258.8759 4.9600e-003

4.7500e-003

260.4514

Library 144.786 1.5600e-003

0.0142 0.0119 9.0000e-005

1.0800e-003

1.0800e-003

1.0800e-003

1.0800e-003

17.0337 17.0337 3.3000e-004

3.1000e-004

17.1374

Medical Office Building

3117.67 0.0336 0.3057 0.2568 1.8300e-003

0.0232 0.0232 0.0232 0.0232 366.7842 366.7842 7.0300e-003

6.7200e-003

369.0164

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 13 of 18

Page 73: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Mobile Home Park

27197.4 0.2933 2.5064 1.0666 0.0160 0.2027 0.2027 0.2027 0.2027 3,199.6987

3,199.6987

0.0613 0.0587 3,219.1716

Motel 11576.7 0.1249 1.1350 0.9534 6.8100e-003

0.0863 0.0863 0.0863 0.0863 1,361.9678

1,361.9678

0.0261 0.0250 1,370.2565

Parking Lot 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Place of Worship 5909.3 0.0637 0.5793 0.4867 3.4800e-003

0.0440 0.0440 0.0440 0.0440 695.2119 695.2119 0.0133 0.0128 699.4429

Regional Shopping Center

9530.39 0.1028 0.9344 0.7849 5.6100e-003

0.0710 0.0710 0.0710 0.0710 1,121.2229

1,121.2229

0.0215 0.0206 1,128.0465

Single Family Housing

179900 1.9401 16.5791 7.0549 0.1058 1.3404 1.3404 1.3404 1.3404 21,164.7567

21,164.7567

0.4057 0.3880 21,293.5619

Strip Mall 3348.91 0.0361 0.3283 0.2758 1.9700e-003

0.0250 0.0250 0.0250 0.0250 393.9894 393.9894 7.5500e-003

7.2200e-003

396.3871

Supermarket 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Unrefrigerated Warehouse-No

Rail

63.6438 6.9000e-004

6.2400e-003

5.2400e-003

4.0000e-005

4.7000e-004

4.7000e-004

4.7000e-004

4.7000e-004

7.4875 7.4875 1.4000e-004

1.4000e-004

7.5331

Total 7.8336 68.9426 43.1614 0.4273 5.4123 5.4123 5.4123 5.4123 85,457.0546

85,457.0546

1.6379 1.5667 85,977.1320

5.2 Energy by Land Use - NaturalGas

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

City Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Condo/Townhouse

179.079 1.9312 16.5033 7.0227 0.1053 1.3343 1.3343 1.3343 1.3343 21,068.0884

21,068.0884

0.4038 0.3863 21,196.3052

Convenience Market (24 Hour)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Mitigated

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 14 of 18

Page 74: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Convenience Market With Gas

Pumps

0.0782998 8.4000e-004

7.6800e-003

6.4500e-003

5.0000e-005

5.8000e-004

5.8000e-004

5.8000e-004

5.8000e-004

9.2118 9.2118 1.8000e-004

1.7000e-004

9.2678

Elementary School

6.47366 0.0698 0.6347 0.5331 3.8100e-003

0.0482 0.0482 0.0482 0.0482 761.6069 761.6069 0.0146 0.0140 766.2419

Enclosed Parking Structure

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Bank (with Drive-Through)

0.387219 4.1800e-003

0.0380 0.0319 2.3000e-004

2.8900e-003

2.8900e-003

2.8900e-003

2.8900e-003

45.5552 45.5552 8.7000e-004

8.4000e-004

45.8324

Fast Food Restaurant with

Drive Thru

21.739 0.2344 2.1313 1.7903 0.0128 0.1620 0.1620 0.1620 0.1620 2,557.5272

2,557.5272

0.0490 0.0469 2,573.0918

General Light Industry

43.1497 0.4653 4.2304 3.5535 0.0254 0.3215 0.3215 0.3215 0.3215 5,076.4335

5,076.4335

0.0973 0.0931 5,107.3279

General Office Building

0.451836 4.8700e-003

0.0443 0.0372 2.7000e-004

3.3700e-003

3.3700e-003

3.3700e-003

3.3700e-003

53.1571 53.1571 1.0200e-003

9.7000e-004

53.4806

Government (Civic Center)

0.387288 4.1800e-003

0.0380 0.0319 2.3000e-004

2.8900e-003

2.8900e-003

2.8900e-003

2.8900e-003

45.5633 45.5633 8.7000e-004

8.4000e-004

45.8406

Government Office Building

20.494 0.2210 2.0092 1.6877 0.0121 0.1527 0.1527 0.1527 0.1527 2,411.0556

2,411.0556

0.0462 0.0442 2,425.7289

High School 0.708734 7.6400e-003

0.0695 0.0584 4.2000e-004

5.2800e-003

5.2800e-003

5.2800e-003

5.2800e-003

83.3805 83.3805 1.6000e-003

1.5300e-003

83.8879

High Turnover (Sit Down Restaurant)

10.8453 0.1170 1.0633 0.8931 6.3800e-003

0.0808 0.0808 0.0808 0.0808 1,275.9156

1,275.9156

0.0245 0.0234 1,283.6806

Hotel 185.228 1.9976 18.1596 15.2540 0.1090 1.3801 1.3801 1.3801 1.3801 21,791.4850

21,791.4850

0.4177 0.3995 21,924.1043

Industrial Park 3.0273 0.0327 0.2968 0.2493 1.7800e-003

0.0226 0.0226 0.0226 0.0226 356.1528 356.1528 6.8300e-003

6.5300e-003

358.3203

Junior College (2Yr)

11.3466 0.1224 1.1124 0.9344 6.6700e-003

0.0845 0.0845 0.0845 0.0845 1,334.8932

1,334.8932

0.0256 0.0245 1,343.0172

Junior High School

2.20045 0.0237 0.2157 0.1812 1.2900e-003

0.0164 0.0164 0.0164 0.0164 258.8759 258.8759 4.9600e-003

4.7500e-003

260.4514

Library 0.144786 1.5600e-003

0.0142 0.0119 9.0000e-005

1.0800e-003

1.0800e-003

1.0800e-003

1.0800e-003

17.0337 17.0337 3.3000e-004

3.1000e-004

17.1374

Medical Office Building

3.11767 0.0336 0.3057 0.2568 1.8300e-003

0.0232 0.0232 0.0232 0.0232 366.7842 366.7842 7.0300e-003

6.7200e-003

369.0164

Mobile Home Park

27.1974 0.2933 2.5064 1.0666 0.0160 0.2027 0.2027 0.2027 0.2027 3,199.6987

3,199.6987

0.0613 0.0587 3,219.1716

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 15 of 18

Page 75: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

6.1 Mitigation Measures Area

6.0 Area Detail

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Motel 11.5767 0.1249 1.1350 0.9534 6.8100e-003

0.0863 0.0863 0.0863 0.0863 1,361.9678

1,361.9678

0.0261 0.0250 1,370.2565

Parking Lot 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Place of Worship 5.9093 0.0637 0.5793 0.4867 3.4800e-003

0.0440 0.0440 0.0440 0.0440 695.2119 695.2119 0.0133 0.0128 699.4429

Regional Shopping Center

9.53039 0.1028 0.9344 0.7849 5.6100e-003

0.0710 0.0710 0.0710 0.0710 1,121.2229

1,121.2229

0.0215 0.0206 1,128.0465

Single Family Housing

179.9 1.9401 16.5791 7.0549 0.1058 1.3404 1.3404 1.3404 1.3404 21,164.7567

21,164.7567

0.4057 0.3880 21,293.5619

Strip Mall 3.34891 0.0361 0.3283 0.2758 1.9700e-003

0.0250 0.0250 0.0250 0.0250 393.9894 393.9894 7.5500e-003

7.2200e-003

396.3871

Supermarket 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Unrefrigerated Warehouse-No

Rail

0.0636438 6.9000e-004

6.2400e-003

5.2400e-003

4.0000e-005

4.7000e-004

4.7000e-004

4.7000e-004

4.7000e-004

7.4875 7.4875 1.4000e-004

1.4000e-004

7.5331

Total 7.8336 68.9426 43.1614 0.4273 5.4123 5.4123 5.4123 5.4123 85,457.0546

85,457.0546

1.6379 1.5667 85,977.1320

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 16 of 18

Page 76: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Unmitigated 11,395.8039

153.7586 13,931.9957

5.2432 1,877.9840

1,877.9840

1,877.9291

1,877.9291 196,568.3101

83,493.7721

280,062.0823

182.4371 15.4616 288,686.3515

Mitigated 11,395.8039

153.7586 13,931.9957

5.2432 1,877.9840

1,877.9840

1,877.9291

1,877.9291 196,568.3101

83,493.7721

280,062.0823

182.4371 15.4616 288,686.3515

6.2 Area by SubCategory

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

SubCategory lb/day lb/day

Architectural Coating

124.9385 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Consumer Products

420.6932 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hearth 10,832.1356

146.9631 13,344.0277

5.2122 1,874.7550

1,874.7550

1,874.7000

1,874.7000 196,568.3101

82,437.8824

279,006.1925

181.3999 15.4616 287,608.6812

Landscaping 18.0367 6.7955 587.9680 0.0310 3.2291 3.2291 3.2291 3.2291 1,055.8898

1,055.8898

1.0372 1,077.6703

Total 11,395.8039

153.7586 13,931.9957

5.2432 1,877.9840

1,877.9840

1,877.9291

1,877.9291 196,568.3101

83,493.7721

280,062.0823

182.4371 15.4616 288,686.3515

Unmitigated

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 17 of 18

Page 77: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

8.1 Mitigation Measures Waste

7.1 Mitigation Measures Water

7.0 Water Detail

8.0 Waste Detail

10.0 Vegetation

6.2 Area by SubCategory

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

SubCategory lb/day lb/day

Architectural Coating

124.9385 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Consumer Products

420.6932 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hearth 10,832.1356

146.9631 13,344.0277

5.2122 1,874.7550

1,874.7550

1,874.7000

1,874.7000 196,568.3101

82,437.8824

279,006.1925

181.3999 15.4616 287,608.6812

Landscaping 18.0367 6.7955 587.9680 0.0310 3.2291 3.2291 3.2291 3.2291 1,055.8898

1,055.8898

1.0372 1,077.6703

Total 11,395.8039

153.7586 13,931.9957

5.2432 1,877.9840

1,877.9840

1,877.9291

1,877.9291 196,568.3101

83,493.7721

280,062.0823

182.4371 15.4616 288,686.3515

Mitigated

9.0 Operational Offroad

Equipment Type Number Hours/Day Days/Year Horse Power Load Factor Fuel Type

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:09 PMPage 18 of 18

Page 78: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

San Diego County, Winter

SYCPU - Changed Proposed (2020)

1.1 Land Usage

Land Uses Size Metric Lot Acreage Floor Surface Area Population

Bank (with Drive-Through) 0.00 1000sqft 0.00 0.00 0

General Office Building 0.00 1000sqft 0.00 0.00 0

Government (Civic Center) 0.00 1000sqft 0.00 0.00 0

Government Office Building 48.70 1000sqft 1.12 48,700.00 0

Medical Office Building 0.00 1000sqft 0.00 0.00 0

Elementary School 635.00 Student 1.22 53,088.14 0

High School 96.70 1000sqft 2.22 96,700.00 0

Junior College (2Yr) 0.00 Student 0.00 0.00 0

Junior High School 141.00 Student 0.38 16,576.20 0

Library 10.70 1000sqft 0.25 10,700.00 0

Place of Worship 0.00 1000sqft 0.00 0.00 0

General Light Industry 0.00 1000sqft 0.00 0.00 0

Industrial Park 0.00 1000sqft 0.00 0.00 0

Unrefrigerated Warehouse-No Rail 22.80 1000sqft 0.52 22,800.00 0

Enclosed Parking Structure 0.00 Acre 0.00 0.00 0

Parking Lot 3,057.00 Space 27.51 1,222,800.00 0

City Park 46.10 Acre 46.10 2,008,116.00 0

Fast Food Restaurant with Drive Thru 0.00 1000sqft 0.00 0.00 0

High Turnover (Sit Down Restaurant) 0.00 1000sqft 0.00 0.00 0

Hotel 0.00 Room 0.00 0.00 0

Motel 0.00 Room 0.00 0.00 0

1.0 Project Characteristics

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 1 of 81

Page 79: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Condo/Townhouse 2,930.00 Dwelling Unit 183.13 2,930,000.00 8380

Mobile Home Park 0.00 Dwelling Unit 0.00 0.00 0

Single Family Housing 0.00 Dwelling Unit 0.00 0.00 0

Convenience Market (24 Hour) 0.00 1000sqft 0.00 0.00 0

Convenience Market With Gas Pumps 0.00 Pump 0.00 0.00 0

Regional Shopping Center 909.80 1000sqft 20.89 909,800.00 0

Strip Mall 518.10 1000sqft 11.89 518,100.00 0

Supermarket 0.00 1000sqft 0.00 0.00 0

1.2 Other Project Characteristics

Urbanization

Climate Zone

Urban

13

Wind Speed (m/s) Precipitation Freq (Days)2.6 40

1.3 User Entered Comments & Non-Default Data

Utility Company San Diego Gas & Electric

2020Operational Year

CO2 Intensity (lb/MWhr)

720.49 0.029CH4 Intensity (lb/MWhr)

0.006N2O Intensity (lb/MWhr)

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 2 of 81

Page 80: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Project Characteristics -

Land Use -

Trips and VMT -

Architectural Coating -

Vehicle Trips - Kimley Horn 2015

Area Coating -

Water And Wastewater -

Solid Waste -

Energy Mitigation -

Water Mitigation -

Waste Mitigation -

Table Name Column Name Default Value New Value

tblProjectCharacteristics OperationalYear 2014 2020

tblVehicleTrips CC_TTP 0.00 80.20

tblVehicleTrips CC_TTP 0.00 80.20

tblVehicleTrips CNW_TTP 0.00 19.00

tblVehicleTrips CNW_TTP 0.00 19.00

tblVehicleTrips CW_TTP 0.00 0.80

tblVehicleTrips CW_TTP 0.00 0.80

tblVehicleTrips PR_TP 0.00 100.00

tblVehicleTrips PR_TP 0.00 100.00

tblVehicleTrips ST_TR 86.32 200.26

tblVehicleTrips ST_TR 1.59 50.66

tblVehicleTrips ST_TR 7.16 6.51

tblVehicleTrips ST_TR 863.10 706.30

tblVehicleTrips ST_TR 204.47 150.23

tblVehicleTrips ST_TR 0.00 107.01

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 3 of 81

Page 81: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

tblVehicleTrips ST_TR 722.03 699.22

tblVehicleTrips ST_TR 1.32 13.42

tblVehicleTrips ST_TR 2.37 25.14

tblVehicleTrips ST_TR 158.37 129.69

tblVehicleTrips ST_TR 8.19 10.03

tblVehicleTrips ST_TR 2.49 16.20

tblVehicleTrips ST_TR 46.55 49.87

tblVehicleTrips ST_TR 8.96 49.96

tblVehicleTrips ST_TR 5.00 4.97

tblVehicleTrips ST_TR 5.63 9.00

tblVehicleTrips ST_TR 0.00 2.26

tblVehicleTrips ST_TR 10.37 11.95

tblVehicleTrips ST_TR 49.97 42.21

tblVehicleTrips ST_TR 10.08 9.01

tblVehicleTrips ST_TR 42.04 93.10

tblVehicleTrips ST_TR 177.59 150.17

tblVehicleTrips ST_TR 2.59 5.10

tblVehicleTrips SU_TR 31.90 200.26

tblVehicleTrips SU_TR 1.59 50.66

tblVehicleTrips SU_TR 6.07 6.51

tblVehicleTrips SU_TR 758.45 706.30

tblVehicleTrips SU_TR 166.88 150.23

tblVehicleTrips SU_TR 0.00 107.01

tblVehicleTrips SU_TR 542.72 699.22

tblVehicleTrips SU_TR 0.68 13.42

tblVehicleTrips SU_TR 0.98 25.14

tblVehicleTrips SU_TR 131.84 129.69

tblVehicleTrips SU_TR 5.95 10.03

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 4 of 81

Page 82: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

tblVehicleTrips SU_TR 0.73 16.20

tblVehicleTrips SU_TR 25.49 49.87

tblVehicleTrips SU_TR 1.55 49.96

tblVehicleTrips SU_TR 4.36 4.97

tblVehicleTrips SU_TR 5.63 9.00

tblVehicleTrips SU_TR 0.00 2.26

tblVehicleTrips SU_TR 36.63 11.95

tblVehicleTrips SU_TR 25.24 42.21

tblVehicleTrips SU_TR 8.77 9.01

tblVehicleTrips SU_TR 20.43 93.10

tblVehicleTrips SU_TR 166.44 150.17

tblVehicleTrips SU_TR 2.59 5.10

tblVehicleTrips WD_TR 148.15 200.26

tblVehicleTrips WD_TR 1.59 50.66

tblVehicleTrips WD_TR 6.59 6.51

tblVehicleTrips WD_TR 737.99 706.30

tblVehicleTrips WD_TR 542.60 150.23

tblVehicleTrips WD_TR 1.29 2.91

tblVehicleTrips WD_TR 0.00 107.01

tblVehicleTrips WD_TR 496.12 699.22

tblVehicleTrips WD_TR 6.97 13.42

tblVehicleTrips WD_TR 11.01 25.14

tblVehicleTrips WD_TR 27.92 29.83

tblVehicleTrips WD_TR 68.93 27.80

tblVehicleTrips WD_TR 12.89 18.00

tblVehicleTrips WD_TR 127.15 129.69

tblVehicleTrips WD_TR 8.17 10.03

tblVehicleTrips WD_TR 6.96 16.20

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 5 of 81

Page 83: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

2.0 Emissions Summary

2.1 Overall Construction (Maximum Daily Emission)

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Year lb/day lb/day

2016 4.3432 45.7249 35.6823 0.0414 0.1232 2.2931 2.4163 0.0327 2.1374 2.1701 0.0000 4,211.6348

4,211.6348

1.1186 0.0000 4,235.1252

2017 6.1663 69.6757 47.5874 0.0637 18.2141 3.3184 20.9694 9.9699 3.0529 12.5048 0.0000 6,470.1987

6,470.1987

1.9425 0.0000 6,510.9902

2018 5.3506 59.6101 43.0133 0.0637 8.8376 2.7892 11.6268 3.6401 2.5661 6.2061 0.0000 6,363.7433

6,363.7433

1.9416 0.0000 6,404.5174

2019 24.5189 114.8381 292.8216 0.6829 40.4672 2.7316 43.1988 10.8823 2.5406 13.4230 0.0000 56,977.2281

56,977.2281

2.2368 0.0000 57,024.2003

Unmitigated Construction

tblVehicleTrips WD_TR 1.20 1.66

tblVehicleTrips WD_TR 1.62 1.41

tblVehicleTrips WD_TR 56.24 49.87

tblVehicleTrips WD_TR 36.13 49.96

tblVehicleTrips WD_TR 4.99 4.97

tblVehicleTrips WD_TR 5.63 9.00

tblVehicleTrips WD_TR 0.00 2.26

tblVehicleTrips WD_TR 9.11 11.95

tblVehicleTrips WD_TR 42.94 42.21

tblVehicleTrips WD_TR 9.57 9.01

tblVehicleTrips WD_TR 44.32 93.10

tblVehicleTrips WD_TR 102.24 150.17

tblVehicleTrips WD_TR 2.59 5.10

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 6 of 81

Page 84: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Year lb/day lb/day

2020 23.0594 100.1886 279.1161 0.6825 40.4668 2.4337 42.9005 10.8821 2.2633 13.1454 0.0000 55,184.4620

55,184.4620

2.1528 0.0000 55,229.6705

2021 21.7040 85.4256 267.0842 0.6826 40.4670 2.1707 42.6377 10.8822 2.0182 12.9004 0.0000 54,676.1909

54,676.1909

2.0946 0.0000 54,720.1782

2022 20.6360 76.1671 254.9951 0.6822 40.4673 2.0075 42.4748 10.8823 1.8656 12.7479 0.0000 54,191.5841

54,191.5841

2.0418 0.0000 54,234.4608

2023 19.4875 67.9736 243.7421 0.6815 40.4678 1.8768 42.3445 10.8825 1.7432 12.6257 0.0000 53,726.7174

53,726.7174

1.9809 0.0000 53,768.3158

2024 18.4614 65.9008 231.8123 0.6814 40.4678 1.7959 42.2637 10.8825 1.6668 12.5493 0.0000 53,360.6311

53,360.6311

1.9381 0.0000 53,401.3311

2025 17.7815 64.0479 224.4809 0.6813 40.4683 1.7156 42.1839 10.8827 1.5912 12.4739 0.0000 53,046.2188

53,046.2188

1.9023 0.0000 53,086.1667

2026 17.3069 63.0350 219.1457 0.6813 40.4689 1.7079 42.1768 10.8830 1.5841 12.4671 0.0000 52,774.6570

52,774.6570

1.8750 0.0000 52,814.0311

2027 16.8486 62.3249 213.1642 0.6812 40.4696 1.7114 42.1810 10.8833 1.5874 12.4706 0.0000 52,541.9880

52,541.9880

1.8524 0.0000 52,580.8875

2028 16.5147 61.6983 209.8429 0.6813 40.4703 1.7119 42.1822 10.8835 1.5878 12.4713 0.0000 52,344.8468

52,344.8468

1.8310 0.0000 52,383.2974

2029 16.1405 61.1488 205.8118 0.6812 40.4709 1.7134 42.1843 10.8838 1.5892 12.4730 0.0000 52,176.4969

52,176.4969

1.8107 0.0000 52,214.5206

2030 15.7644 56.1962 203.0460 0.6852 40.4715 1.3373 41.8088 10.8840 1.2441 12.1281 0.0000 52,372.9730

52,372.9730

1.3103 0.0000 52,400.4890

2031 15.4940 55.8175 200.9058 0.6852 40.4709 1.3383 41.8092 10.8838 1.2450 12.1288 0.0000 52,249.6931

52,249.6931

1.2946 0.0000 52,276.8797

2032 15.2435 55.5025 199.0510 0.6852 40.4704 1.3388 41.8092 10.8835 1.2456 12.1291 0.0000 52,146.8195

52,146.8195

1.2808 0.0000 52,173.7160

2033 14.9728 55.1702 197.4284 0.6852 40.4697 1.3389 41.8086 10.8832 1.2456 12.1288 0.0000 52,059.6524

52,059.6524

1.2678 0.0000 52,086.2763

2034 14.7202 54.9198 195.8290 0.6851 40.4690 1.3386 41.8076 10.8829 1.2453 12.1283 0.0000 51,986.2802

51,986.2802

1.2555 0.0000 52,012.6452

2035 14.4134 53.9581 194.5227 0.6851 40.4683 1.2807 41.7490 10.8826 1.1875 12.0701 0.0000 51,925.6595

51,925.6595

1.2364 0.0000 51,951.6237

2036 1.2123 7.1510 16.0922 0.0308 34.1170 0.0901 34.2070 8.3742 0.0901 8.4642 0.0000 2,884.8300

2,884.8300

0.1075 0.0000 2,887.0878

2037 1.3349 7.1510 16.0922 0.0308 34.1170 0.1832 34.2070 8.3742 0.1832 8.4642 0.0000 2,884.8300

2,884.8300

0.1075 0.0000 2,887.0878

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 7 of 81

Page 85: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Year lb/day lb/day

2038 539.2361 4.7892 15.4905 0.0275 5.7472 0.1832 5.7571 1.4107 0.1832 1.4206 0.0000 2,599.9866

2,599.9866

0.1001 0.0000 2,602.0881

2039 539.2361 0.7577 1.7943 2.9700e-003

5.7472 9.9000e-003

5.7571 1.4107 9.9000e-003

1.4206 0.0000 281.4481 281.4481 0.0104 0.0000 281.6665

Total 1,399.9471

1,349.1723

4,008.5519

11.8712 794.8748 38.4158 832.4611 218.2227 35.6731 253.1114 0.0000 929,438.7701

929,438.7701

34.6897 0.0000 930,167.2529

2.1 Overall Construction (Maximum Daily Emission)

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Year lb/day lb/day

2016 4.3432 45.7249 35.6823 0.0414 0.1232 2.2931 2.4163 0.0327 2.1374 2.1701 0.0000 4,211.6348

4,211.6348

1.1186 0.0000 4,235.1252

2017 6.1663 69.6757 47.5874 0.0637 18.2141 3.3184 20.9694 9.9699 3.0529 12.5048 0.0000 6,470.1986

6,470.1986

1.9425 0.0000 6,510.9902

2018 5.3506 59.6101 43.0133 0.0637 8.8376 2.7892 11.6268 3.6401 2.5661 6.2061 0.0000 6,363.7433

6,363.7433

1.9416 0.0000 6,404.5174

2019 24.5189 114.8381 292.8216 0.6829 40.4672 2.7316 43.1988 10.8823 2.5406 13.4230 0.0000 56,977.2281

56,977.2281

2.2368 0.0000 57,024.2003

2020 23.0594 100.1886 279.1161 0.6825 40.4668 2.4337 42.9005 10.8821 2.2633 13.1454 0.0000 55,184.4620

55,184.4620

2.1528 0.0000 55,229.6705

2021 21.7040 85.4256 267.0842 0.6826 40.4670 2.1707 42.6377 10.8822 2.0182 12.9004 0.0000 54,676.1909

54,676.1909

2.0946 0.0000 54,720.1782

2022 20.6360 76.1671 254.9951 0.6822 40.4673 2.0075 42.4748 10.8823 1.8656 12.7479 0.0000 54,191.5841

54,191.5841

2.0418 0.0000 54,234.4608

2023 19.4875 67.9736 243.7421 0.6815 40.4678 1.8768 42.3445 10.8825 1.7432 12.6257 0.0000 53,726.7174

53,726.7174

1.9809 0.0000 53,768.3158

2024 18.4614 65.9008 231.8123 0.6814 40.4678 1.7959 42.2637 10.8825 1.6668 12.5493 0.0000 53,360.6311

53,360.6311

1.9381 0.0000 53,401.3311

2025 17.7815 64.0479 224.4809 0.6813 40.4683 1.7156 42.1839 10.8827 1.5912 12.4739 0.0000 53,046.2188

53,046.2188

1.9023 0.0000 53,086.1667

Mitigated Construction

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 8 of 81

Page 86: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Year lb/day lb/day

2026 17.3069 63.0350 219.1457 0.6813 40.4689 1.7079 42.1768 10.8830 1.5841 12.4671 0.0000 52,774.6570

52,774.6570

1.8750 0.0000 52,814.0311

2027 16.8486 62.3249 213.1642 0.6812 40.4696 1.7114 42.1810 10.8833 1.5874 12.4706 0.0000 52,541.9880

52,541.9880

1.8524 0.0000 52,580.8875

2028 16.5147 61.6983 209.8429 0.6813 40.4703 1.7119 42.1822 10.8835 1.5878 12.4713 0.0000 52,344.8468

52,344.8468

1.8310 0.0000 52,383.2974

2029 16.1405 61.1488 205.8118 0.6812 40.4709 1.7134 42.1843 10.8838 1.5892 12.4730 0.0000 52,176.4969

52,176.4969

1.8107 0.0000 52,214.5206

2030 15.7644 56.1962 203.0460 0.6852 40.4715 1.3373 41.8088 10.8840 1.2441 12.1281 0.0000 52,372.9730

52,372.9730

1.3103 0.0000 52,400.4890

2031 15.4940 55.8175 200.9058 0.6852 40.4709 1.3383 41.8092 10.8838 1.2450 12.1288 0.0000 52,249.6931

52,249.6931

1.2946 0.0000 52,276.8797

2032 15.2435 55.5025 199.0510 0.6852 40.4704 1.3388 41.8092 10.8835 1.2456 12.1291 0.0000 52,146.8195

52,146.8195

1.2808 0.0000 52,173.7160

2033 14.9728 55.1702 197.4284 0.6852 40.4697 1.3389 41.8086 10.8832 1.2456 12.1288 0.0000 52,059.6524

52,059.6524

1.2678 0.0000 52,086.2763

2034 14.7202 54.9198 195.8290 0.6851 40.4690 1.3386 41.8076 10.8829 1.2453 12.1283 0.0000 51,986.2802

51,986.2802

1.2555 0.0000 52,012.6452

2035 14.4134 53.9581 194.5227 0.6851 40.4683 1.2807 41.7490 10.8826 1.1875 12.0701 0.0000 51,925.6595

51,925.6595

1.2364 0.0000 51,951.6237

2036 1.2123 7.1510 16.0922 0.0308 34.1170 0.0901 34.2070 8.3742 0.0901 8.4642 0.0000 2,884.8300

2,884.8300

0.1075 0.0000 2,887.0878

2037 1.3349 7.1510 16.0922 0.0308 34.1170 0.1832 34.2070 8.3742 0.1832 8.4642 0.0000 2,884.8300

2,884.8300

0.1075 0.0000 2,887.0878

2038 539.2361 4.7892 15.4905 0.0275 5.7472 0.1832 5.7571 1.4107 0.1832 1.4206 0.0000 2,599.9866

2,599.9866

0.1001 0.0000 2,602.0881

2039 539.2361 0.7577 1.7943 2.9700e-003

5.7472 9.9000e-003

5.7571 1.4107 9.9000e-003

1.4206 0.0000 281.4481 281.4481 0.0104 0.0000 281.6665

Total 1,399.9471

1,349.1723

4,008.5519

11.8712 794.8748 38.4158 832.4611 218.2227 35.6731 253.1114 0.0000 929,438.7701

929,438.7701

34.6897 0.0000 930,167.2529

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e

Percent Reduction

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 9 of 81

Page 87: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

2.2 Overall Operational

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Area 4,707.9578

63.6470 5,766.9729

2.1704 777.4068 777.4068 777.3841 777.3841 81,371.1710

34,562.3413

115,933.5123

75.5197 6.4005 119,503.5682

Energy 1.3561 11.6774 5.5805 0.0740 0.9370 0.9370 0.9370 0.9370 14,794.3080

14,794.3080

0.2836 0.2712 14,884.3436

Mobile 344.4514 584.7715 3,011.0643

7.0121 491.1023 8.3369 499.4392 131.0916 7.6935 138.7851 536,361.2370

536,361.2370

21.5718 536,814.2446

Total 5,053.7653

660.0958 8,783.6177

9.2565 491.1023 786.6807 1,277.7830

131.0916 786.0145 917.1061 81,371.1710

585,717.8862

667,089.0572

97.3751 6.6717 671,202.1565

Unmitigated Operational

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Area 4,707.9578

63.6470 5,766.9729

2.1704 777.4068 777.4068 777.3841 777.3841 81,371.1710

34,562.3413

115,933.5123

75.5197 6.4005 119,503.5682

Energy 1.0963 9.4422 4.5299 0.0598 0.7574 0.7574 0.7574 0.7574 11,959.1870

11,959.1870

0.2292 0.2193 12,031.9686

Mobile 344.4514 584.7715 3,011.0643

7.0121 491.1023 8.3369 499.4392 131.0916 7.6935 138.7851 536,361.2370

536,361.2370

21.5718 536,814.2446

Total 5,053.5054

657.8606 8,782.5672

9.2424 491.1023 786.5012 1,277.6035

131.0916 785.8350 916.9266 81,371.1710

582,882.7652

664,253.9363

97.3207 6.6197 668,349.7814

Mitigated Operational

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 10 of 81

Page 88: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.0 Construction Detail

Construction Phase

Phase Number

Phase Name Phase Type Start Date End Date Num Days Week

Num Days Phase Description

1 Demolition Demolition 1/1/2016 2/23/2017 5 300

2 Site Preparation Site Preparation 2/24/2017 11/2/2017 5 180

3 Grading Grading 11/3/2017 8/15/2019 5 465

4 Building Construction Building Construction 8/16/2019 6/11/2037 5 4650

5 Paving Paving 6/12/2037 9/16/2038 5 330

6 Architectural Coating Architectural Coating 9/17/2038 12/22/2039 5 330

OffRoad Equipment

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e

Percent Reduction

0.01 0.34 0.01 0.15 0.00 0.02 0.01 0.00 0.02 0.02 0.00 0.48 0.42 0.06 0.78 0.42

Residential Indoor: 5,933,250; Residential Outdoor: 1,977,750; Non-Residential Indoor: 5,581,897; Non-Residential Outdoor: 1,860,632 (Architectural Coating – sqft)

Acres of Grading (Site Preparation Phase): 0

Acres of Grading (Grading Phase): 1162.5

Acres of Paving: 0

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 11 of 81

Page 89: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Phase Name Offroad Equipment Type Amount Usage Hours Horse Power Load Factor

Demolition Concrete/Industrial Saws 1 8.00 81 0.73

Demolition Excavators 3 8.00 162 0.38

Demolition Rubber Tired Dozers 2 8.00 255 0.40

Site Preparation Rubber Tired Dozers 3 8.00 255 0.40

Site Preparation Tractors/Loaders/Backhoes 4 8.00 97 0.37

Grading Excavators 2 8.00 162 0.38

Grading Graders 1 8.00 174 0.41

Grading Rubber Tired Dozers 1 8.00 255 0.40

Grading Scrapers 2 8.00 361 0.48

Grading Tractors/Loaders/Backhoes 2 8.00 97 0.37

Building Construction Cranes 1 7.00 226 0.29

Building Construction Forklifts 3 8.00 89 0.20

Building Construction Generator Sets 1 8.00 84 0.74

Building Construction Tractors/Loaders/Backhoes 3 7.00 97 0.37

Building Construction Welders 1 8.00 46 0.45

Paving Pavers 2 8.00 125 0.42

Paving Paving Equipment 2 8.00 130 0.36

Paving Rollers 2 8.00 80 0.38

Architectural Coating Air Compressors 1 6.00 78 0.48

Trips and VMT

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 12 of 81

Page 90: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.2 Demolition - 2016

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 4.2876 45.6559 35.0303 0.0399 2.2921 2.2921 2.1365 2.1365 4,089.2841

4,089.2841

1.1121 4,112.6374

Total 4.2876 45.6559 35.0303 0.0399 2.2921 2.2921 2.1365 2.1365 4,089.2841

4,089.2841

1.1121 4,112.6374

Unmitigated Construction On-Site

3.1 Mitigation Measures Construction

Phase Name Offroad Equipment Count

Worker Trip Number

Vendor Trip Number

Hauling Trip Number

Worker Trip Length

Vendor Trip Length

Hauling Trip Length

Worker Vehicle Class

Vendor Vehicle Class

Hauling Vehicle Class

Demolition 6 15.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

Site Preparation 7 18.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

Grading 8 20.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

Building Construction 9 4,023.00 1,118.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

Paving 6 15.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

Architectural Coating 1 805.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 13 of 81

Page 91: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.2 Demolition - 2016

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0556 0.0690 0.6519 1.4700e-003

0.1232 9.2000e-004

0.1242 0.0327 8.5000e-004

0.0335 122.3507 122.3507 6.5300e-003

122.4878

Total 0.0556 0.0690 0.6519 1.4700e-003

0.1232 9.2000e-004

0.1242 0.0327 8.5000e-004

0.0335 122.3507 122.3507 6.5300e-003

122.4878

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 4.2876 45.6559 35.0303 0.0399 2.2921 2.2921 2.1365 2.1365 0.0000 4,089.2841

4,089.2841

1.1121 4,112.6374

Total 4.2876 45.6559 35.0303 0.0399 2.2921 2.2921 2.1365 2.1365 0.0000 4,089.2841

4,089.2841

1.1121 4,112.6374

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 14 of 81

Page 92: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.2 Demolition - 2016

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0556 0.0690 0.6519 1.4700e-003

0.1232 9.2000e-004

0.1242 0.0327 8.5000e-004

0.0335 122.3507 122.3507 6.5300e-003

122.4878

Total 0.0556 0.0690 0.6519 1.4700e-003

0.1232 9.2000e-004

0.1242 0.0327 8.5000e-004

0.0335 122.3507 122.3507 6.5300e-003

122.4878

Mitigated Construction Off-Site

3.2 Demolition - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 4.0482 42.6971 33.8934 0.0399 2.1252 2.1252 1.9797 1.9797 4,036.4674

4,036.4674

1.1073 4,059.7211

Total 4.0482 42.6971 33.8934 0.0399 2.1252 2.1252 1.9797 1.9797 4,036.4674

4,036.4674

1.1073 4,059.7211

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 15 of 81

Page 93: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.2 Demolition - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0504 0.0628 0.5868 1.4700e-003

0.1232 9.0000e-004

0.1241 0.0327 8.3000e-004

0.0335 117.6222 117.6222 6.0400e-003

117.7491

Total 0.0504 0.0628 0.5868 1.4700e-003

0.1232 9.0000e-004

0.1241 0.0327 8.3000e-004

0.0335 117.6222 117.6222 6.0400e-003

117.7491

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 4.0482 42.6971 33.8934 0.0399 2.1252 2.1252 1.9797 1.9797 0.0000 4,036.4674

4,036.4674

1.1073 4,059.7211

Total 4.0482 42.6971 33.8934 0.0399 2.1252 2.1252 1.9797 1.9797 0.0000 4,036.4674

4,036.4674

1.1073 4,059.7211

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 16 of 81

Page 94: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.2 Demolition - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0504 0.0628 0.5868 1.4700e-003

0.1232 9.0000e-004

0.1241 0.0327 8.3000e-004

0.0335 117.6222 117.6222 6.0400e-003

117.7491

Total 0.0504 0.0628 0.5868 1.4700e-003

0.1232 9.0000e-004

0.1241 0.0327 8.3000e-004

0.0335 117.6222 117.6222 6.0400e-003

117.7491

Mitigated Construction Off-Site

3.3 Site Preparation - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 18.0663 0.0000 18.0663 9.9307 0.0000 9.9307 0.0000 0.0000

Off-Road 4.8382 51.7535 39.3970 0.0391 2.7542 2.7542 2.5339 2.5339 4,003.0859

4,003.0859

1.2265 4,028.8432

Total 4.8382 51.7535 39.3970 0.0391 18.0663 2.7542 20.8205 9.9307 2.5339 12.4646 4,003.0859

4,003.0859

1.2265 4,028.8432

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 17 of 81

Page 95: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.3 Site Preparation - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0604 0.0753 0.7041 1.7600e-003

0.1479 1.0800e-003

0.1489 0.0392 9.9000e-004

0.0402 141.1467 141.1467 7.2500e-003

141.2989

Total 0.0604 0.0753 0.7041 1.7600e-003

0.1479 1.0800e-003

0.1489 0.0392 9.9000e-004

0.0402 141.1467 141.1467 7.2500e-003

141.2989

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 18.0663 0.0000 18.0663 9.9307 0.0000 9.9307 0.0000 0.0000

Off-Road 4.8382 51.7535 39.3970 0.0391 2.7542 2.7542 2.5339 2.5339 0.0000 4,003.0859

4,003.0859

1.2265 4,028.8432

Total 4.8382 51.7535 39.3970 0.0391 18.0663 2.7542 20.8205 9.9307 2.5339 12.4646 0.0000 4,003.0859

4,003.0859

1.2265 4,028.8432

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 18 of 81

Page 96: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.3 Site Preparation - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0604 0.0753 0.7041 1.7600e-003

0.1479 1.0800e-003

0.1489 0.0392 9.9000e-004

0.0402 141.1467 141.1467 7.2500e-003

141.2989

Total 0.0604 0.0753 0.7041 1.7600e-003

0.1479 1.0800e-003

0.1489 0.0392 9.9000e-004

0.0402 141.1467 141.1467 7.2500e-003

141.2989

Mitigated Construction Off-Site

3.4 Grading - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 8.6733 0.0000 8.6733 3.5965 0.0000 3.5965 0.0000 0.0000

Off-Road 6.0991 69.5920 46.8050 0.0617 3.3172 3.3172 3.0518 3.0518 6,313.3690

6,313.3690

1.9344 6,353.9915

Total 6.0991 69.5920 46.8050 0.0617 8.6733 3.3172 11.9905 3.5965 3.0518 6.6483 6,313.3690

6,313.3690

1.9344 6,353.9915

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 19 of 81

Page 97: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.4 Grading - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0671 0.0837 0.7823 1.9500e-003

0.1643 1.1900e-003

0.1655 0.0436 1.1000e-003

0.0447 156.8296 156.8296 8.0500e-003

156.9987

Total 0.0671 0.0837 0.7823 1.9500e-003

0.1643 1.1900e-003

0.1655 0.0436 1.1000e-003

0.0447 156.8296 156.8296 8.0500e-003

156.9987

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 8.6733 0.0000 8.6733 3.5965 0.0000 3.5965 0.0000 0.0000

Off-Road 6.0991 69.5920 46.8050 0.0617 3.3172 3.3172 3.0518 3.0518 0.0000 6,313.3690

6,313.3690

1.9344 6,353.9915

Total 6.0991 69.5920 46.8050 0.0617 8.6733 3.3172 11.9905 3.5965 3.0518 6.6483 0.0000 6,313.3690

6,313.3690

1.9344 6,353.9915

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 20 of 81

Page 98: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.4 Grading - 2017

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0671 0.0837 0.7823 1.9500e-003

0.1643 1.1900e-003

0.1655 0.0436 1.1000e-003

0.0447 156.8296 156.8296 8.0500e-003

156.9987

Total 0.0671 0.0837 0.7823 1.9500e-003

0.1643 1.1900e-003

0.1655 0.0436 1.1000e-003

0.0447 156.8296 156.8296 8.0500e-003

156.9987

Mitigated Construction Off-Site

3.4 Grading - 2018

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 8.6733 0.0000 8.6733 3.5965 0.0000 3.5965 0.0000 0.0000

Off-Road 5.2895 59.5338 42.3068 0.0617 2.7880 2.7880 2.5650 2.5650 6,212.8042

6,212.8042

1.9341 6,253.4209

Total 5.2895 59.5338 42.3068 0.0617 8.6733 2.7880 11.4614 3.5965 2.5650 6.1615 6,212.8042

6,212.8042

1.9341 6,253.4209

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 21 of 81

Page 99: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.4 Grading - 2018

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0610 0.0763 0.7065 1.9500e-003

0.1643 1.1700e-003

0.1655 0.0436 1.0800e-003

0.0447 150.9392 150.9392 7.4900e-003

151.0965

Total 0.0610 0.0763 0.7065 1.9500e-003

0.1643 1.1700e-003

0.1655 0.0436 1.0800e-003

0.0447 150.9392 150.9392 7.4900e-003

151.0965

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 8.6733 0.0000 8.6733 3.5965 0.0000 3.5965 0.0000 0.0000

Off-Road 5.2895 59.5338 42.3068 0.0617 2.7880 2.7880 2.5650 2.5650 0.0000 6,212.8041

6,212.8041

1.9341 6,253.4209

Total 5.2895 59.5338 42.3068 0.0617 8.6733 2.7880 11.4614 3.5965 2.5650 6.1615 0.0000 6,212.8041

6,212.8041

1.9341 6,253.4209

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 22 of 81

Page 100: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.4 Grading - 2018

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0610 0.0763 0.7065 1.9500e-003

0.1643 1.1700e-003

0.1655 0.0436 1.0800e-003

0.0447 150.9392 150.9392 7.4900e-003

151.0965

Total 0.0610 0.0763 0.7065 1.9500e-003

0.1643 1.1700e-003

0.1655 0.0436 1.0800e-003

0.0447 150.9392 150.9392 7.4900e-003

151.0965

Mitigated Construction Off-Site

3.4 Grading - 2019

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 8.6733 0.0000 8.6733 3.5965 0.0000 3.5965 0.0000 0.0000

Off-Road 4.8912 54.1978 40.2888 0.0617 2.5049 2.5049 2.3045 2.3045 6,111.3121

6,111.3121

1.9336 6,151.9167

Total 4.8912 54.1978 40.2888 0.0617 8.6733 2.5049 11.1783 3.5965 2.3045 5.9010 6,111.3121

6,111.3121

1.9336 6,151.9167

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 23 of 81

Page 101: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.4 Grading - 2019

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0566 0.0705 0.6492 1.9500e-003

0.1643 1.1600e-003

0.1655 0.0436 1.0800e-003

0.0447 145.4776 145.4776 7.0400e-003

145.6256

Total 0.0566 0.0705 0.6492 1.9500e-003

0.1643 1.1600e-003

0.1655 0.0436 1.0800e-003

0.0447 145.4776 145.4776 7.0400e-003

145.6256

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Fugitive Dust 8.6733 0.0000 8.6733 3.5965 0.0000 3.5965 0.0000 0.0000

Off-Road 4.8912 54.1978 40.2888 0.0617 2.5049 2.5049 2.3045 2.3045 0.0000 6,111.3121

6,111.3121

1.9336 6,151.9167

Total 4.8912 54.1978 40.2888 0.0617 8.6733 2.5049 11.1783 3.5965 2.3045 5.9010 0.0000 6,111.3121

6,111.3121

1.9336 6,151.9167

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 24 of 81

Page 102: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.4 Grading - 2019

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.0566 0.0705 0.6492 1.9500e-003

0.1643 1.1600e-003

0.1655 0.0436 1.0800e-003

0.0447 145.4776 145.4776 7.0400e-003

145.6256

Total 0.0566 0.0705 0.6492 1.9500e-003

0.1643 1.1600e-003

0.1655 0.0436 1.0800e-003

0.0447 145.4776 145.4776 7.0400e-003

145.6256

Mitigated Construction Off-Site

3.5 Building Construction - 2019

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 2.3516 20.9650 17.1204 0.0268 1.2850 1.2850 1.2083 1.2083 2,580.7618

2,580.7618

0.6279 2,593.9479

Total 2.3516 20.9650 17.1204 0.0268 1.2850 1.2850 1.2083 1.2083 2,580.7618

2,580.7618

0.6279 2,593.9479

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 25 of 81

Page 103: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2019

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 10.7770 79.6830 145.1235 0.2633 7.4192 1.2125 8.6317 2.1165 1.1153 3.2318 25,133.6447

25,133.6447

0.1918 25,137.6717

Worker 11.3903 14.1900 130.5778 0.3929 33.0480 0.2341 33.2821 8.7659 0.2170 8.9829 29,262.8217

29,262.8217

1.4171 29,292.5807

Total 22.1673 93.8730 275.7012 0.6561 40.4672 1.4466 41.9138 10.8823 1.3323 12.2147 54,396.4664

54,396.4664

1.6089 54,430.2524

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 2.3516 20.9650 17.1204 0.0268 1.2850 1.2850 1.2083 1.2083 0.0000 2,580.7618

2,580.7618

0.6279 2,593.9479

Total 2.3516 20.9650 17.1204 0.0268 1.2850 1.2850 1.2083 1.2083 0.0000 2,580.7618

2,580.7618

0.6279 2,593.9479

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 26 of 81

Page 104: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2019

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 10.7770 79.6830 145.1235 0.2633 7.4192 1.2125 8.6317 2.1165 1.1153 3.2318 25,133.6447

25,133.6447

0.1918 25,137.6717

Worker 11.3903 14.1900 130.5778 0.3929 33.0480 0.2341 33.2821 8.7659 0.2170 8.9829 29,262.8217

29,262.8217

1.4171 29,292.5807

Total 22.1673 93.8730 275.7012 0.6561 40.4672 1.4466 41.9138 10.8823 1.3323 12.2147 54,396.4664

54,396.4664

1.6089 54,430.2524

Mitigated Construction Off-Site

3.5 Building Construction - 2020

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 2.1113 19.0839 16.8084 0.0268 1.1128 1.1128 1.0465 1.0465 2,542.4799

2,542.4799

0.6194 2,555.4880

Total 2.1113 19.0839 16.8084 0.0268 1.1128 1.1128 1.0465 1.0465 2,542.4799

2,542.4799

0.6194 2,555.4880

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 27 of 81

Page 105: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2020

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 10.1771 67.8485 140.3416 0.2629 7.4188 1.0864 8.5052 2.1163 0.9994 3.1157 24,558.5521

24,558.5521

0.1858 24,562.4539

Worker 10.7711 13.2562 121.9660 0.3928 33.0480 0.2345 33.2824 8.7659 0.2174 8.9833 28,083.4300

28,083.4300

1.3476 28,111.7286

Total 20.9482 81.1047 262.3076 0.6557 40.4668 1.3208 41.7876 10.8821 1.2168 12.0990 52,641.9821

52,641.9821

1.5334 52,674.1825

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 2.1113 19.0839 16.8084 0.0268 1.1128 1.1128 1.0465 1.0465 0.0000 2,542.4799

2,542.4799

0.6194 2,555.4880

Total 2.1113 19.0839 16.8084 0.0268 1.1128 1.1128 1.0465 1.0465 0.0000 2,542.4799

2,542.4799

0.6194 2,555.4880

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 28 of 81

Page 106: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2020

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 10.1771 67.8485 140.3416 0.2629 7.4188 1.0864 8.5052 2.1163 0.9994 3.1157 24,558.5521

24,558.5521

0.1858 24,562.4539

Worker 10.7711 13.2562 121.9660 0.3928 33.0480 0.2345 33.2824 8.7659 0.2174 8.9833 28,083.4300

28,083.4300

1.3476 28,111.7286

Total 20.9482 81.1047 262.3076 0.6557 40.4668 1.3208 41.7876 10.8821 1.2168 12.0990 52,641.9821

52,641.9821

1.5334 52,674.1825

Mitigated Construction Off-Site

3.5 Building Construction - 2021

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.8931 17.3403 16.5376 0.0268 0.9549 0.9549 0.8979 0.8979 2,542.7817

2,542.7817

0.6126 2,555.6462

Total 1.8931 17.3403 16.5376 0.0268 0.9549 0.9549 0.8979 0.8979 2,542.7817

2,542.7817

0.6126 2,555.6462

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 29 of 81

Page 107: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2021

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 9.5587 55.6420 135.0045 0.2624 7.4190 0.9777 8.3967 2.1163 0.8995 3.0159 24,519.1690

24,519.1690

0.1853 24,523.0610

Worker 10.2523 12.4434 115.5421 0.3935 33.0480 0.2381 33.2861 8.7659 0.2209 8.9867 27,614.2402

27,614.2402

1.2967 27,641.4710

Total 19.8109 68.0854 250.5466 0.6558 40.4670 1.2158 41.6828 10.8822 1.1204 12.0026 52,133.4092

52,133.4092

1.4820 52,164.5320

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.8931 17.3403 16.5376 0.0268 0.9549 0.9549 0.8979 0.8979 0.0000 2,542.7817

2,542.7817

0.6126 2,555.6462

Total 1.8931 17.3403 16.5376 0.0268 0.9549 0.9549 0.8979 0.8979 0.0000 2,542.7817

2,542.7817

0.6126 2,555.6462

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 30 of 81

Page 108: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2021

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 9.5587 55.6420 135.0045 0.2624 7.4190 0.9777 8.3967 2.1163 0.8995 3.0159 24,519.1690

24,519.1690

0.1853 24,523.0610

Worker 10.2523 12.4434 115.5421 0.3935 33.0480 0.2381 33.2861 8.7659 0.2209 8.9867 27,614.2402

27,614.2402

1.2967 27,641.4710

Total 19.8109 68.0854 250.5466 0.6558 40.4670 1.2158 41.6828 10.8822 1.1204 12.0026 52,133.4092

52,133.4092

1.4820 52,164.5320

Mitigated Construction Off-Site

3.5 Building Construction - 2022

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.6992 15.5364 16.3276 0.0268 0.8057 0.8057 0.7581 0.7581 2,543.7497

2,543.7497

0.6085 2,556.5286

Total 1.6992 15.5364 16.3276 0.0268 0.8057 0.8057 0.7581 0.7581 2,543.7497

2,543.7497

0.6085 2,556.5286

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 31 of 81

Page 109: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2022

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 9.1668 48.8784 129.6854 0.2620 7.4193 0.9619 8.3813 2.1165 0.8850 3.0015 24,493.7784

24,493.7784

0.1892 24,497.7521

Worker 9.7701 11.7523 108.9822 0.3934 33.0480 0.2398 33.2878 8.7659 0.2224 8.9883 27,154.0560

27,154.0560

1.2440 27,180.1801

Total 18.9368 60.6307 238.6675 0.6554 40.4673 1.2017 41.6690 10.8823 1.1074 11.9898 51,647.8344

51,647.8344

1.4332 51,677.9321

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.6992 15.5364 16.3276 0.0268 0.8057 0.8057 0.7581 0.7581 0.0000 2,543.7497

2,543.7497

0.6085 2,556.5286

Total 1.6992 15.5364 16.3276 0.0268 0.8057 0.8057 0.7581 0.7581 0.0000 2,543.7497

2,543.7497

0.6085 2,556.5286

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 32 of 81

Page 110: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2022

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 9.1668 48.8784 129.6854 0.2620 7.4193 0.9619 8.3813 2.1165 0.8850 3.0015 24,493.7784

24,493.7784

0.1892 24,497.7521

Worker 9.7701 11.7523 108.9822 0.3934 33.0480 0.2398 33.2878 8.7659 0.2224 8.9883 27,154.0560

27,154.0560

1.2440 27,180.1801

Total 18.9368 60.6307 238.6675 0.6554 40.4673 1.2017 41.6690 10.8823 1.1074 11.9898 51,647.8344

51,647.8344

1.4332 51,677.9321

Mitigated Construction Off-Site

3.5 Building Construction - 2023

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.5661 14.3126 16.2093 0.0268 0.6967 0.6967 0.6557 0.6557 2,544.6262

2,544.6262

0.6044 2,557.3191

Total 1.5661 14.3126 16.2093 0.0268 0.6967 0.6967 0.6557 0.6557 2,544.6262

2,544.6262

0.6044 2,557.3191

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 33 of 81

Page 111: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2023

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 8.5929 42.5183 124.4324 0.2613 7.4198 0.9385 8.3583 2.1166 0.8635 2.9801 24,438.6381

24,438.6381

0.1779 24,442.3741

Worker 9.3285 11.1427 103.1005 0.3934 33.0480 0.2415 33.2895 8.7659 0.2241 8.9899 26,743.4531

26,743.4531

1.1986 26,768.6226

Total 17.9214 53.6609 227.5329 0.6547 40.4678 1.1800 41.6478 10.8825 1.0875 11.9700 51,182.0912

51,182.0912

1.3765 51,210.9967

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.5661 14.3126 16.2093 0.0268 0.6967 0.6967 0.6557 0.6557 0.0000 2,544.6262

2,544.6262

0.6044 2,557.3191

Total 1.5661 14.3126 16.2093 0.0268 0.6967 0.6967 0.6557 0.6557 0.0000 2,544.6262

2,544.6262

0.6044 2,557.3191

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 34 of 81

Page 112: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2023

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 8.5929 42.5183 124.4324 0.2613 7.4198 0.9385 8.3583 2.1166 0.8635 2.9801 24,438.6381

24,438.6381

0.1779 24,442.3741

Worker 9.3285 11.1427 103.1005 0.3934 33.0480 0.2415 33.2895 8.7659 0.2241 8.9899 26,743.4531

26,743.4531

1.1986 26,768.6226

Total 17.9214 53.6609 227.5329 0.6547 40.4678 1.1800 41.6478 10.8825 1.0875 11.9700 51,182.0912

51,182.0912

1.3765 51,210.9967

Mitigated Construction Off-Site

3.5 Building Construction - 2024

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.4653 13.3774 16.1332 0.0268 0.6106 0.6106 0.5744 0.5744 2,545.1154

2,545.1154

0.6009 2,557.7349

Total 1.4653 13.3774 16.1332 0.0268 0.6106 0.6106 0.5744 0.5744 2,545.1154

2,545.1154

0.6009 2,557.7349

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 35 of 81

Page 113: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2024

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 8.0731 41.9144 117.5336 0.2612 7.4198 0.9419 8.3617 2.1167 0.8666 2.9833 24,437.0510

24,437.0510

0.1785 24,440.7987

Worker 8.9230 10.6090 98.1455 0.3933 33.0480 0.2434 33.2914 8.7659 0.2258 8.9917 26,378.4647

26,378.4647

1.1587 26,402.7975

Total 16.9961 52.5234 215.6791 0.6545 40.4678 1.1853 41.6531 10.8825 1.0924 11.9749 50,815.5157

50,815.5157

1.3372 50,843.5962

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.4653 13.3774 16.1332 0.0268 0.6106 0.6106 0.5744 0.5744 0.0000 2,545.1154

2,545.1154

0.6009 2,557.7349

Total 1.4653 13.3774 16.1332 0.0268 0.6106 0.6106 0.5744 0.5744 0.0000 2,545.1154

2,545.1154

0.6009 2,557.7349

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 36 of 81

Page 114: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2024

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 8.0731 41.9144 117.5336 0.2612 7.4198 0.9419 8.3617 2.1167 0.8666 2.9833 24,437.0510

24,437.0510

0.1785 24,440.7987

Worker 8.9230 10.6090 98.1455 0.3933 33.0480 0.2434 33.2914 8.7659 0.2258 8.9917 26,378.4647

26,378.4647

1.1587 26,402.7975

Total 16.9961 52.5234 215.6791 0.6545 40.4678 1.1853 41.6531 10.8825 1.0924 11.9749 50,815.5157

50,815.5157

1.3372 50,843.5962

Mitigated Construction Off-Site

3.5 Building Construction - 2025

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 37 of 81

Page 115: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2025

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.8410 41.4709 114.3830 0.2611 7.4203 0.9449 8.3652 2.1168 0.8694 2.9862 24,439.1289

24,439.1289

0.1790 24,442.8868

Worker 8.5790 10.1673 94.0461 0.3933 33.0480 0.2457 33.2937 8.7659 0.2279 8.9938 26,061.1994

26,061.1994

1.1258 26,084.8414

Total 16.4200 51.6382 208.4291 0.6545 40.4683 1.1906 41.6589 10.8827 1.0973 11.9800 50,500.3283

50,500.3283

1.3048 50,527.7282

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 38 of 81

Page 116: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2025

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.8410 41.4709 114.3830 0.2611 7.4203 0.9449 8.3652 2.1168 0.8694 2.9862 24,439.1289

24,439.1289

0.1790 24,442.8868

Worker 8.5790 10.1673 94.0461 0.3933 33.0480 0.2457 33.2937 8.7659 0.2279 8.9938 26,061.1994

26,061.1994

1.1258 26,084.8414

Total 16.4200 51.6382 208.4291 0.6545 40.4683 1.1906 41.6589 10.8827 1.0973 11.9800 50,500.3283

50,500.3283

1.3048 50,527.7282

Mitigated Construction Off-Site

3.5 Building Construction - 2026

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 39 of 81

Page 117: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2026

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.6506 40.8031 112.2013 0.2611 7.4209 0.9345 8.3554 2.1171 0.8598 2.9769 24,441.2089

24,441.2089

0.1776 24,444.9391

Worker 8.2948 9.8223 90.8926 0.3933 33.0480 0.2484 33.2964 8.7659 0.2305 8.9963 25,787.5575

25,787.5575

1.0998 25,810.6535

Total 15.9454 50.6253 203.0939 0.6544 40.4689 1.1829 41.6518 10.8830 1.0902 11.9732 50,228.7664

50,228.7664

1.2774 50,255.5926

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 40 of 81

Page 118: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2026

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.6506 40.8031 112.2013 0.2611 7.4209 0.9345 8.3554 2.1171 0.8598 2.9769 24,441.2089

24,441.2089

0.1776 24,444.9391

Worker 8.2948 9.8223 90.8926 0.3933 33.0480 0.2484 33.2964 8.7659 0.2305 8.9963 25,787.5575

25,787.5575

1.0998 25,810.6535

Total 15.9454 50.6253 203.0939 0.6544 40.4689 1.1829 41.6518 10.8830 1.0902 11.9732 50,228.7664

50,228.7664

1.2774 50,255.5926

Mitigated Construction Off-Site

3.5 Building Construction - 2027

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 41 of 81

Page 119: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2027

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.4552 40.3889 109.0004 0.2611 7.4216 0.9357 8.3573 2.1174 0.8609 2.9782 24,444.1733

24,444.1733

0.1779 24,447.9095

Worker 8.0319 9.5263 88.1121 0.3933 33.0480 0.2507 33.2987 8.7659 0.2326 8.9985 25,551.9242

25,551.9242

1.0769 25,574.5394

Total 15.4871 49.9152 197.1125 0.6544 40.4696 1.1864 41.6560 10.8833 1.0934 11.9767 49,996.0975

49,996.0975

1.2548 50,022.4489

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 42 of 81

Page 120: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2027

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.4552 40.3889 109.0004 0.2611 7.4216 0.9357 8.3573 2.1174 0.8609 2.9782 24,444.1733

24,444.1733

0.1779 24,447.9095

Worker 8.0319 9.5263 88.1121 0.3933 33.0480 0.2507 33.2987 8.7659 0.2326 8.9985 25,551.9242

25,551.9242

1.0769 25,574.5394

Total 15.4871 49.9152 197.1125 0.6544 40.4696 1.1864 41.6560 10.8833 1.0934 11.9767 49,996.0975

49,996.0975

1.2548 50,022.4489

Mitigated Construction Off-Site

3.5 Building Construction - 2028

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 43 of 81

Page 121: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2028

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.3767 40.0490 108.1968 0.2611 7.4223 0.9341 8.3564 2.1177 0.8594 2.9771 24,447.6602

24,447.6602

0.1778 24,451.3943

Worker 7.7766 9.2396 85.5943 0.3933 33.0480 0.2528 33.3007 8.7659 0.2345 9.0004 25,351.2961

25,351.2961

1.0556 25,373.4645

Total 15.1533 49.2887 193.7911 0.6544 40.4703 1.1868 41.6572 10.8835 1.0939 11.9774 49,798.9562

49,798.9562

1.2335 49,824.8588

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 44 of 81

Page 122: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2028

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.3767 40.0490 108.1968 0.2611 7.4223 0.9341 8.3564 2.1177 0.8594 2.9771 24,447.6602

24,447.6602

0.1778 24,451.3943

Worker 7.7766 9.2396 85.5943 0.3933 33.0480 0.2528 33.3007 8.7659 0.2345 9.0004 25,351.2961

25,351.2961

1.0556 25,373.4645

Total 15.1533 49.2887 193.7911 0.6544 40.4703 1.1868 41.6572 10.8835 1.0939 11.9774 49,798.9562

49,798.9562

1.2335 49,824.8588

Mitigated Construction Off-Site

3.5 Building Construction - 2029

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 2,545.8905

2,545.8905

0.5975 2,558.4386

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 45 of 81

Page 123: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2029

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.2534 39.7809 106.5827 0.2611 7.4230 0.9340 8.3569 2.1179 0.8593 2.9772 24,450.3654

24,450.3654

0.1779 24,454.1012

Worker 7.5256 8.9582 83.1773 0.3933 33.0480 0.2544 33.3023 8.7659 0.2360 9.0019 25,180.2410

25,180.2410

1.0352 25,201.9808

Total 14.7791 48.7392 189.7600 0.6544 40.4709 1.1883 41.6593 10.8838 1.0953 11.9791 49,630.6064

49,630.6064

1.2131 49,656.0820

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Total 1.3615 12.4097 16.0518 0.0269 0.5250 0.5250 0.4939 0.4939 0.0000 2,545.8905

2,545.8905

0.5975 2,558.4386

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 46 of 81

Page 124: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2029

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.2534 39.7809 106.5827 0.2611 7.4230 0.9340 8.3569 2.1179 0.8593 2.9772 24,450.3654

24,450.3654

0.1779 24,454.1012

Worker 7.5256 8.9582 83.1773 0.3933 33.0480 0.2544 33.3023 8.7659 0.2360 9.0019 25,180.2410

25,180.2410

1.0352 25,201.9808

Total 14.7791 48.7392 189.7600 0.6544 40.4709 1.1883 41.6593 10.8838 1.0953 11.9791 49,630.6064

49,630.6064

1.2131 49,656.0820

Mitigated Construction Off-Site

3.5 Building Construction - 2030

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 47 of 81

Page 125: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2030

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.1705 39.5704 105.8908 0.2611 7.4235 0.9342 8.3577 2.1181 0.8595 2.9776 24,453.1630

24,453.1630

0.1780 24,456.9007

Worker 7.2899 8.7079 81.0239 0.3933 33.0480 0.2555 33.3035 8.7659 0.2371 9.0029 25,034.9801

25,034.9801

1.0165 25,056.3266

Total 14.4603 48.2783 186.9147 0.6544 40.4715 1.1897 41.6612 10.8840 1.0965 11.9805 49,488.1430

49,488.1430

1.1945 49,513.2272

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 48 of 81

Page 126: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2030

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.1705 39.5704 105.8908 0.2611 7.4235 0.9342 8.3577 2.1181 0.8595 2.9776 24,453.1630

24,453.1630

0.1780 24,456.9007

Worker 7.2899 8.7079 81.0239 0.3933 33.0480 0.2555 33.3035 8.7659 0.2371 9.0029 25,034.9801

25,034.9801

1.0165 25,056.3266

Total 14.4603 48.2783 186.9147 0.6544 40.4715 1.1897 41.6612 10.8840 1.0965 11.9805 49,488.1430

49,488.1430

1.1945 49,513.2272

Mitigated Construction Off-Site

3.5 Building Construction - 2031

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 49 of 81

Page 127: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2031

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.1032 39.4102 105.4655 0.2611 7.4229 0.9345 8.3574 2.1179 0.8597 2.9776 24,451.8458

24,451.8458

0.1781 24,455.5853

Worker 7.0867 8.4894 79.3090 0.3933 33.0480 0.2562 33.3042 8.7659 0.2377 9.0036 24,913.0173

24,913.0173

1.0007 24,934.0328

Total 14.1899 47.8996 184.7745 0.6544 40.4709 1.1907 41.6616 10.8838 1.0974 11.9812 49,364.8632

49,364.8632

1.1788 49,389.6180

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 50 of 81

Page 128: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2031

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.1032 39.4102 105.4655 0.2611 7.4229 0.9345 8.3574 2.1179 0.8597 2.9776 24,451.8458

24,451.8458

0.1781 24,455.5853

Worker 7.0867 8.4894 79.3090 0.3933 33.0480 0.2562 33.3042 8.7659 0.2377 9.0036 24,913.0173

24,913.0173

1.0007 24,934.0328

Total 14.1899 47.8996 184.7745 0.6544 40.4709 1.1907 41.6616 10.8838 1.0974 11.9812 49,364.8632

49,364.8632

1.1788 49,389.6180

Mitigated Construction Off-Site

3.5 Building Construction - 2032

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 51 of 81

Page 129: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2032

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.0383 39.2786 105.1288 0.2611 7.4224 0.9346 8.3570 2.1177 0.8598 2.9775 24,450.7628

24,450.7628

0.1781 24,454.5035

Worker 6.9011 8.3060 77.7909 0.3933 33.0480 0.2566 33.3046 8.7659 0.2381 9.0040 24,811.2267

24,811.2267

0.9869 24,831.9507

Total 13.9393 47.5846 182.9197 0.6544 40.4704 1.1912 41.6616 10.8835 1.0980 11.9815 49,261.9895

49,261.9895

1.1650 49,286.4543

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 52 of 81

Page 130: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2032

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 7.0383 39.2786 105.1288 0.2611 7.4224 0.9346 8.3570 2.1177 0.8598 2.9775 24,450.7628

24,450.7628

0.1781 24,454.5035

Worker 6.9011 8.3060 77.7909 0.3933 33.0480 0.2566 33.3046 8.7659 0.2381 9.0040 24,811.2267

24,811.2267

0.9869 24,831.9507

Total 13.9393 47.5846 182.9197 0.6544 40.4704 1.1912 41.6616 10.8835 1.0980 11.9815 49,261.9895

49,261.9895

1.1650 49,286.4543

Mitigated Construction Off-Site

3.5 Building Construction - 2033

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 53 of 81

Page 131: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2033

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 6.9571 39.1192 104.8517 0.2611 7.4217 0.9344 8.3561 2.1174 0.8597 2.9770 24,448.1230

24,448.1230

0.1781 24,451.8639

Worker 6.7116 8.1332 76.4454 0.3933 33.0480 0.2569 33.3049 8.7659 0.2383 9.0042 24,726.6995

24,726.6995

0.9739 24,747.1508

Total 13.6687 47.2524 181.2971 0.6543 40.4697 1.1913 41.6610 10.8832 1.0980 11.9812 49,174.8225

49,174.8225

1.1520 49,199.0146

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 54 of 81

Page 132: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2033

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 6.9571 39.1192 104.8517 0.2611 7.4217 0.9344 8.3561 2.1174 0.8597 2.9770 24,448.1230

24,448.1230

0.1781 24,451.8639

Worker 6.7116 8.1332 76.4454 0.3933 33.0480 0.2569 33.3049 8.7659 0.2383 9.0042 24,726.6995

24,726.6995

0.9739 24,747.1508

Total 13.6687 47.2524 181.2971 0.6543 40.4697 1.1913 41.6610 10.8832 1.0980 11.9812 49,174.8225

49,174.8225

1.1520 49,199.0146

Mitigated Construction Off-Site

3.5 Building Construction - 2034

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 2,884.8300

2,884.8300

0.1158 2,887.2617

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 55 of 81

Page 133: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2034

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 6.8930 39.0112 104.6220 0.2610 7.4210 0.9341 8.3551 2.1171 0.8594 2.9765 24,445.9976

24,445.9976

0.1781 24,449.7382

Worker 6.5231 7.9907 75.0756 0.3933 33.0480 0.2569 33.3048 8.7659 0.2383 9.0042 24,655.4526

24,655.4526

0.9616 24,675.6453

Total 13.4161 47.0019 179.6976 0.6543 40.4690 1.1910 41.6600 10.8829 1.0977 11.9807 49,101.4503

49,101.4503

1.1397 49,125.3835

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Total 1.3041 7.9179 16.1313 0.0308 0.1476 0.1476 0.1476 0.1476 0.0000 2,884.8300

2,884.8300

0.1158 2,887.2617

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 56 of 81

Page 134: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2034

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 6.8930 39.0112 104.6220 0.2610 7.4210 0.9341 8.3551 2.1171 0.8594 2.9765 24,445.9976

24,445.9976

0.1781 24,449.7382

Worker 6.5231 7.9907 75.0756 0.3933 33.0480 0.2569 33.3048 8.7659 0.2383 9.0042 24,655.4526

24,655.4526

0.9616 24,675.6453

Total 13.4161 47.0019 179.6976 0.6543 40.4690 1.1910 41.6600 10.8829 1.0977 11.9807 49,101.4503

49,101.4503

1.1397 49,125.3835

Mitigated Construction Off-Site

3.5 Building Construction - 2035

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 2,884.8300

2,884.8300

0.1075 2,887.0878

Total 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 2,884.8300

2,884.8300

0.1075 2,887.0878

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 57 of 81

Page 135: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2035

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 6.8456 38.9324 104.4487 0.2610 7.4203 0.9339 8.3542 2.1168 0.8592 2.9760 24,444.0679

24,444.0679

0.1781 24,447.8082

Worker 6.3555 7.8747 73.9818 0.3933 33.0480 0.2568 33.3048 8.7659 0.2382 9.0041 24,596.7616

24,596.7616

0.9508 24,616.7276

Total 13.2011 46.8071 178.4305 0.6543 40.4683 1.1907 41.6589 10.8826 1.0974 11.9801 49,040.8296

49,040.8296

1.1289 49,064.5359

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 0.0000 2,884.8300

2,884.8300

0.1075 2,887.0878

Total 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 0.0000 2,884.8300

2,884.8300

0.1075 2,887.0878

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 58 of 81

Page 136: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2035

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 6.8456 38.9324 104.4487 0.2610 7.4203 0.9339 8.3542 2.1168 0.8592 2.9760 24,444.0679

24,444.0679

0.1781 24,447.8082

Worker 6.3555 7.8747 73.9818 0.3933 33.0480 0.2568 33.3048 8.7659 0.2382 9.0041 24,596.7616

24,596.7616

0.9508 24,616.7276

Total 13.2011 46.8071 178.4305 0.6543 40.4683 1.1907 41.6589 10.8826 1.0974 11.9801 49,040.8296

49,040.8296

1.1289 49,064.5359

Mitigated Construction Off-Site

3.5 Building Construction - 2036

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 2,884.8300

2,884.8300

0.1075 2,887.0878

Total 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 2,884.8300

2,884.8300

0.1075 2,887.0878

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 59 of 81

Page 137: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2036

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 5.3951 0.0000 5.3951 1.3243 0.0000 1.3243 0.0000 0.0000

Worker 28.7218 0.0000 28.7218 7.0499 0.0000 7.0499 0.0000 0.0000

Total 34.1170 0.0000 34.1170 8.3742 0.0000 8.3742 0.0000 0.0000

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 0.0000 2,884.8300

2,884.8300

0.1075 2,887.0878

Total 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 0.0000 2,884.8300

2,884.8300

0.1075 2,887.0878

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 60 of 81

Page 138: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2036

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 5.3951 0.0000 5.3951 1.3243 0.0000 1.3243 0.0000 0.0000

Worker 28.7218 0.0000 28.7218 7.0499 0.0000 7.0499 0.0000 0.0000

Total 34.1170 0.0000 34.1170 8.3742 0.0000 8.3742 0.0000 0.0000

Mitigated Construction Off-Site

3.5 Building Construction - 2037

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 2,884.8300

2,884.8300

0.1075 2,887.0878

Total 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 2,884.8300

2,884.8300

0.1075 2,887.0878

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 61 of 81

Page 139: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2037

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 5.3951 0.0000 5.3951 1.3243 0.0000 1.3243 0.0000 0.0000

Worker 28.7218 0.0000 28.7218 7.0499 0.0000 7.0499 0.0000 0.0000

Total 34.1170 0.0000 34.1170 8.3742 0.0000 8.3742 0.0000 0.0000

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 0.0000 2,884.8300

2,884.8300

0.1075 2,887.0878

Total 1.2123 7.1510 16.0922 0.0308 0.0901 0.0901 0.0901 0.0901 0.0000 2,884.8300

2,884.8300

0.1075 2,887.0878

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 62 of 81

Page 140: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.5 Building Construction - 2037

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 5.3951 0.0000 5.3951 1.3243 0.0000 1.3243 0.0000 0.0000

Worker 28.7218 0.0000 28.7218 7.0499 0.0000 7.0499 0.0000 0.0000

Total 34.1170 0.0000 34.1170 8.3742 0.0000 8.3742 0.0000 0.0000

Mitigated Construction Off-Site

3.6 Paving - 2037

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.1165 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 2,599.9866

2,599.9866

0.1001 2,602.0881

Paving 0.2184 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Total 1.3349 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 2,599.9866

2,599.9866

0.1001 2,602.0881

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 63 of 81

Page 141: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.6 Paving - 2037

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Total 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.1165 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 0.0000 2,599.9866

2,599.9866

0.1001 2,602.0881

Paving 0.2184 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Total 1.3349 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 0.0000 2,599.9866

2,599.9866

0.1001 2,602.0881

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 64 of 81

Page 142: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.6 Paving - 2037

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Total 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Mitigated Construction Off-Site

3.6 Paving - 2038

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.1165 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 2,599.9866

2,599.9866

0.1001 2,602.0881

Paving 0.2184 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Total 1.3349 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 2,599.9866

2,599.9866

0.1001 2,602.0881

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 65 of 81

Page 143: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.6 Paving - 2038

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Total 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Off-Road 1.1165 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 0.0000 2,599.9866

2,599.9866

0.1001 2,602.0881

Paving 0.2184 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Total 1.3349 4.7892 15.4905 0.0275 0.1832 0.1832 0.1832 0.1832 0.0000 2,599.9866

2,599.9866

0.1001 2,602.0881

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 66 of 81

Page 144: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.6 Paving - 2038

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Total 0.1071 0.0000 0.1071 0.0263 0.0000 0.0263 0.0000 0.0000

Mitigated Construction Off-Site

3.7 Architectural Coating - 2038

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Archit. Coating 539.1182 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Off-Road 0.1179 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

281.4481 281.4481 0.0104 281.6665

Total 539.2361 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

281.4481 281.4481 0.0104 281.6665

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 67 of 81

Page 145: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.7 Architectural Coating - 2038

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Total 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Archit. Coating 539.1182 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Off-Road 0.1179 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

0.0000 281.4481 281.4481 0.0104 281.6665

Total 539.2361 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

0.0000 281.4481 281.4481 0.0104 281.6665

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 68 of 81

Page 146: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.7 Architectural Coating - 2038

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Total 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Mitigated Construction Off-Site

3.7 Architectural Coating - 2039

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Archit. Coating 539.1182 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Off-Road 0.1179 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

281.4481 281.4481 0.0104 281.6665

Total 539.2361 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

281.4481 281.4481 0.0104 281.6665

Unmitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 69 of 81

Page 147: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

3.7 Architectural Coating - 2039

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Total 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Unmitigated Construction Off-Site

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Archit. Coating 539.1182 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Off-Road 0.1179 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

0.0000 281.4481 281.4481 0.0104 281.6665

Total 539.2361 0.7577 1.7943 2.9700e-003

9.9000e-003

9.9000e-003

9.9000e-003

9.9000e-003

0.0000 281.4481 281.4481 0.0104 281.6665

Mitigated Construction On-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 70 of 81

Page 148: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

4.0 Operational Detail - Mobile

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Mitigated 344.4514 584.7715 3,011.0643

7.0121 491.1023 8.3369 499.4392 131.0916 7.6935 138.7851 536,361.2370

536,361.2370

21.5718 536,814.2446

Unmitigated 344.4514 584.7715 3,011.0643

7.0121 491.1023 8.3369 499.4392 131.0916 7.6935 138.7851 536,361.2370

536,361.2370

21.5718 536,814.2446

4.1 Mitigation Measures Mobile

3.7 Architectural Coating - 2039

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Worker 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Total 5.7472 0.0000 5.7472 1.4107 0.0000 1.4107 0.0000 0.0000

Mitigated Construction Off-Site

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 71 of 81

Page 149: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

4.2 Trip Summary Information

4.3 Trip Type Information

Average Daily Trip Rate Unmitigated Mitigated

Land Use Weekday Saturday Sunday Annual VMT Annual VMT

Bank (with Drive-Through) 0.00 0.00 0.00

City Park 2,335.43 2,335.43 2335.43 4,985,791 4,985,791

Condo/Townhouse 19,074.30 19,074.30 19074.30 54,462,913 54,462,913

Convenience Market (24 Hour) 0.00 0.00 0.00

Convenience Market With Gas Pumps 0.00 0.00 0.00

Elementary School 1,847.85 0.00 0.00 2,910,283 2,910,283

Enclosed Parking Structure 0.00 0.00 0.00

Fast Food Restaurant with Drive Thru 0.00 0.00 0.00

General Light Industry 0.00 0.00 0.00

General Office Building 0.00 0.00 0.00

Government (Civic Center) 0.00 0.00 0.00

Government Office Building 1,353.86 0.00 0.00 1,658,363 1,658,363

High School 1,740.60 422.58 173.09 3,477,918 3,477,918

High Turnover (Sit Down Restaurant) 0.00 0.00 0.00

Hotel 0.00 0.00 0.00

Industrial Park 0.00 0.00 0.00

Junior College (2Yr) 0.00 0.00 0.00

Junior High School 198.81 0.00 0.00 319,260 319,260

Library 533.61 533.61 533.61 904,391 904,391

Medical Office Building 0.00 0.00 0.00

Mobile Home Park 0.00 0.00 0.00

Motel 0.00 0.00 0.00

Parking Lot 6,908.82 6,908.82 6908.82 18,402,377 18,402,377

Place of Worship 0.00 0.00 0.00

Regional Shopping Center 38,402.66 38,402.66 38402.66 67,331,566 67,331,566

Single Family Housing 0.00 0.00 0.00

Strip Mall 48,235.11 48,235.11 48235.11 74,283,663 74,283,663

Supermarket 0.00 0.00 0.00

Unrefrigerated Warehouse-No Rail 116.28 116.28 116.28 339,481 339,481

Total 120,747.32 116,028.78 115,779.30 229,076,004 229,076,004

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 72 of 81

Page 150: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

Miles Trip % Trip Purpose %

Land Use H-W or C-W H-S or C-C H-O or C-NW H-W or C-W H-S or C-C H-O or C-NW Primary Diverted Pass-by

Bank (with Drive-Through) 9.50 7.30 7.30 6.60 74.40 19.00 27 26 47

City Park 9.50 7.30 7.30 33.00 48.00 19.00 66 28 6

Condo/Townhouse 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Convenience Market (24 Hour) 9.50 7.30 7.30 0.90 80.10 19.00 24 15 61

Convenience Market With Gas Pumps

9.50 7.30 7.30 0.80 80.20 19.00 14 21 65

Elementary School 9.50 7.30 7.30 65.00 30.00 5.00 63 25 12

Enclosed Parking Structure 9.50 7.30 7.30 0.80 80.20 19.00 100 0 0

Fast Food Restaurant with Drive Thru

9.50 7.30 7.30 2.20 78.80 19.00 29 21 50

General Light Industry 9.50 7.30 7.30 59.00 28.00 13.00 92 5 3

General Office Building 9.50 7.30 7.30 33.00 48.00 19.00 77 19 4

Government (Civic Center) 9.50 7.30 7.30 75.00 20.00 5.00 50 34 16

Government Office Building 9.50 7.30 7.30 33.00 62.00 5.00 50 34 16

High School 9.50 7.30 7.30 77.80 17.20 5.00 75 19 6

High Turnover (Sit Down Restaurant)

9.50 7.30 7.30 8.50 72.50 19.00 37 20 43

Hotel 9.50 7.30 7.30 19.40 61.60 19.00 58 38 4

Industrial Park 9.50 7.30 7.30 59.00 28.00 13.00 79 19 2

Junior College (2Yr) 9.50 7.30 7.30 6.40 88.60 5.00 92 7 1

Junior High School 9.50 7.30 7.30 72.80 22.20 5.00 63 25 12

Library 9.50 7.30 7.30 52.00 43.00 5.00 44 44 12

Medical Office Building 9.50 7.30 7.30 29.60 51.40 19.00 60 30 10

Mobile Home Park 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Motel 9.50 7.30 7.30 19.00 62.00 19.00 58 38 4

Parking Lot 9.50 7.30 7.30 0.80 80.20 19.00 100 0 0

Place of Worship 9.50 7.30 7.30 0.00 95.00 5.00 64 25 11

Regional Shopping Center 9.50 7.30 7.30 16.30 64.70 19.00 54 35 11

Single Family Housing 10.80 7.30 7.50 41.60 18.80 39.60 86 11 3

Strip Mall 9.50 7.30 7.30 16.60 64.40 19.00 45 40 15

Supermarket 9.50 7.30 7.30 6.50 74.50 19.00 34 30 36

Unrefrigerated Warehouse-No Rail

9.50 7.30 7.30 59.00 0.00 41.00 92 5 3

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 73 of 81

Page 151: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

5.0 Energy Detail

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

NaturalGas Mitigated

1.0963 9.4422 4.5299 0.0598 0.7574 0.7574 0.7574 0.7574 11,959.1870

11,959.1870

0.2292 0.2193 12,031.9686

NaturalGas Unmitigated

1.3561 11.6774 5.5805 0.0740 0.9370 0.9370 0.9370 0.9370 14,794.3080

14,794.3080

0.2836 0.2712 14,884.3436

5.2 Energy by Land Use - NaturalGas

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Condo/Townhouse

110706 1.1939 10.2023 4.3414 0.0651 0.8249 0.8249 0.8249 0.8249 13,024.2632

13,024.2632

0.2496 0.2388 13,103.5267

Unmitigated

5.1 Mitigation Measures Energy

Exceed Title 24

4.4 Fleet Mix

LDA LDT1 LDT2 MDV LHD1 LHD2 MHD HHD OBUS UBUS MCY SBUS MH

0.513300 0.073549 0.191092 0.130830 0.036094 0.005140 0.012550 0.022916 0.001871 0.002062 0.006564 0.000586 0.003446

Historical Energy Use: N

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 74 of 81

Page 152: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Convenience Market (24 Hour)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Convenience Market With Gas

Pumps

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Elementary School

901.771 9.7200e-003

0.0884 0.0743 5.3000e-004

6.7200e-003

6.7200e-003

6.7200e-003

6.7200e-003

106.0907 106.0907 2.0300e-003

1.9400e-003

106.7364

Enclosed Parking Structure

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Fast Food Restaurant with

Drive Thru

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

General Light Industry

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

General Office Building

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Government (Civic Center)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Government Office Building

2805.92 0.0303 0.2751 0.2311 1.6500e-003

0.0209 0.0209 0.0209 0.0209 330.1083 330.1083 6.3300e-003

6.0500e-003

332.1173

High School 1642.58 0.0177 0.1610 0.1353 9.7000e-004

0.0122 0.0122 0.0122 0.0122 193.2442 193.2442 3.7000e-003

3.5400e-003

194.4202

High Turnover (Sit Down Restaurant)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hotel 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Industrial Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Junior College (2Yr)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Junior High School

281.568 3.0400e-003

0.0276 0.0232 1.7000e-004

2.1000e-003

2.1000e-003

2.1000e-003

2.1000e-003

33.1257 33.1257 6.3000e-004

6.1000e-004

33.3273

Library 345.625 3.7300e-003

0.0339 0.0285 2.0000e-004

2.5800e-003

2.5800e-003

2.5800e-003

2.5800e-003

40.6617 40.6617 7.8000e-004

7.5000e-004

40.9092

Medical Office Building

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Mobile Home Park

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 75 of 81

Page 153: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Motel 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Parking Lot 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Place of Worship 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Regional Shopping Center

5708.06 0.0616 0.5596 0.4701 3.3600e-003

0.0425 0.0425 0.0425 0.0425 671.5365 671.5365 0.0129 0.0123 675.6234

Single Family Housing

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Strip Mall 3250.55 0.0351 0.3187 0.2677 1.9100e-003

0.0242 0.0242 0.0242 0.0242 382.4171 382.4171 7.3300e-003

7.0100e-003

384.7444

Supermarket 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Unrefrigerated Warehouse-No

Rail

109.315 1.1800e-003

0.0107 9.0000e-003

6.0000e-005

8.1000e-004

8.1000e-004

8.1000e-004

8.1000e-004

12.8606 12.8606 2.5000e-004

2.4000e-004

12.9389

Bank (with Drive-Through)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

City Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Total 1.3561 11.6774 5.5805 0.0740 0.9370 0.9370 0.9370 0.9370 14,794.3079

14,794.3079

0.2836 0.2712 14,884.3436

5.2 Energy by Land Use - NaturalGas

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Condo/Townhouse

89.0534 0.9604 8.2069 3.4923 0.0524 0.6635 0.6635 0.6635 0.6635 10,476.8678

10,476.8678

0.2008 0.1921 10,540.6283

Convenience Market (24 Hour)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Mitigated

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 76 of 81

Page 154: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Convenience Market With Gas

Pumps

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Elementary School

0.693782 7.4800e-003

0.0680 0.0571 4.1000e-004

5.1700e-003

5.1700e-003

5.1700e-003

5.1700e-003

81.6214 81.6214 1.5600e-003

1.5000e-003

82.1182

Enclosed Parking Structure

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Fast Food Restaurant with

Drive Thru

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

General Light Industry

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

General Office Building

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Government (Civic Center)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Government Office Building

2.24454 0.0242 0.2201 0.1848 1.3200e-003

0.0167 0.0167 0.0167 0.0167 264.0631 264.0631 5.0600e-003

4.8400e-003

265.6701

High School 1.26372 0.0136 0.1239 0.1041 7.4000e-004

9.4200e-003

9.4200e-003

9.4200e-003

9.4200e-003

148.6733 148.6733 2.8500e-003

2.7300e-003

149.5781

High Turnover (Sit Down Restaurant)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hotel 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Industrial Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Junior College (2Yr)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Junior High School

0.216626 2.3400e-003

0.0212 0.0178 1.3000e-004

1.6100e-003

1.6100e-003

1.6100e-003

1.6100e-003

25.4854 25.4854 4.9000e-004

4.7000e-004

25.6405

Library 0.312352 3.3700e-003

0.0306 0.0257 1.8000e-004

2.3300e-003

2.3300e-003

2.3300e-003

2.3300e-003

36.7473 36.7473 7.0000e-004

6.7000e-004

36.9709

Medical Office Building

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Mobile Home Park

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Motel 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 77 of 81

Page 155: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

6.1 Mitigation Measures Area

6.0 Area Detail

NaturalGas Use

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Land Use kBTU/yr lb/day lb/day

Parking Lot 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Place of Worship 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Regional Shopping Center

4.96028 0.0535 0.4863 0.4085 2.9200e-003

0.0370 0.0370 0.0370 0.0370 583.5623 583.5623 0.0112 0.0107 587.1138

Single Family Housing

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Strip Mall 2.82471 0.0305 0.2769 0.2326 1.6600e-003

0.0211 0.0211 0.0211 0.0211 332.3188 332.3188 6.3700e-003

6.0900e-003

334.3412

Supermarket 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Unrefrigerated Warehouse-No

Rail

0.0837041 9.0000e-004

8.2100e-003

6.8900e-003

5.0000e-005

6.2000e-004

6.2000e-004

6.2000e-004

6.2000e-004

9.8475 9.8475 1.9000e-004

1.8000e-004

9.9075

Bank (with Drive-Through)

0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

City Park 0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Total 1.0963 9.4421 4.5299 0.0598 0.7574 0.7574 0.7574 0.7574 11,959.1870

11,959.1870

0.2292 0.2193 12,031.9686

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 78 of 81

Page 156: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

Category lb/day lb/day

Mitigated 4,707.9578

63.6470 5,766.9729

2.1704 777.4068 777.4068 777.3841 777.3841 81,371.1710

34,562.3413

115,933.5123

75.5197 6.4005 119,503.5682

Unmitigated 4,707.9578

63.6470 5,766.9729

2.1704 777.4068 777.4068 777.3841 777.3841 81,371.1710

34,562.3413

115,933.5123

75.5197 6.4005 119,503.5682

6.2 Area by SubCategory

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

SubCategory lb/day lb/day

Architectural Coating

48.7422 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Consumer Products

167.7199 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hearth 4,484.0572

60.8367 5,523.8770

2.1576 776.0712 776.0712 776.0485 776.0485 81,371.1710

34,125.8824

115,497.0534

75.0921 6.4005 119,058.1288

Landscaping 7.4384 2.8103 243.0960 0.0128 1.3356 1.3356 1.3356 1.3356 436.4589 436.4589 0.4276 445.4394

Total 4,707.9578

63.6470 5,766.9729

2.1704 777.4068 777.4068 777.3841 777.3841 81,371.1710

34,562.3413

115,933.5123

75.5197 6.4005 119,503.5682

Unmitigated

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 79 of 81

Page 157: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

8.1 Mitigation Measures Waste

Institute Recycling and Composting Services

Apply Water Conservation Strategy

7.1 Mitigation Measures Water

7.0 Water Detail

8.0 Waste Detail

6.2 Area by SubCategory

ROG NOx CO SO2 Fugitive PM10

Exhaust PM10

PM10 Total

Fugitive PM2.5

Exhaust PM2.5

PM2.5 Total

Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e

SubCategory lb/day lb/day

Architectural Coating

48.7422 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Consumer Products

167.7199 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

Hearth 4,484.0572

60.8367 5,523.8770

2.1576 776.0712 776.0712 776.0485 776.0485 81,371.1710

34,125.8824

115,497.0534

75.0921 6.4005 119,058.1288

Landscaping 7.4384 2.8103 243.0960 0.0128 1.3356 1.3356 1.3356 1.3356 436.4589 436.4589 0.4276 445.4394

Total 4,707.9578

63.6470 5,766.9729

2.1704 777.4068 777.4068 777.3841 777.3841 81,371.1710

34,562.3413

115,933.5123

75.5197 6.4005 119,503.5682

Mitigated

9.0 Operational Offroad

Equipment Type Number Hours/Day Days/Year Horse Power Load Factor Fuel Type

CalEEMod Version: CalEEMod.2013.2.2 Date: 9/24/2015 10:06 PMPage 80 of 81

Page 158: San Ysidro Community Plan Update and San Ysidro Historic ... · Air Quality Technical Report for the San Ysidro Community Plan Update Project / SDD-20 / May 2016 1 1.0 INTRODUCTION

10.0 Vegetation