    IMPORTANT!

    PROPER INTRUSION PROTECTION

    For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include anyskylights that may be present, and the upper windows in a multi-level building.

    In addition, we recommend that radio backup be used in a security system sothat alarm signals can still be sent to the Customer Care Center in the event

    that the telephone lines are out of order (alarm signals are normally sent overthe phone lines).

    EARLY WARNING FIRE DETECTION

    Early warning fire detection is important in a home. Smoke and heat detectorshave played a key role in reducing fire deaths in the United States. With regardto the number and placement of smoke/heat detectors, we subscribe to therecommendations contained in the National Fire Protection Association'sNational Fire Alarm Code (NFPA 72). These recommendations can be found onpage 34 of this manual.

    This manual is a step-by-step guide that will acquaint you with the system'sfeatures and benefits. It defines the components and their functions, describestheir operation, and provides clear step-by-step instructions for normal andemergency procedures. Keep this manual in a convenient place so that you canrefer to it as necessary.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    3/56

    3

    System Overview....................................................................................................................5Int roduction .......................................................................................................................... 5Sy stem B a sics ....................................................................................................................... 5

    About The Touchpads ...........................................................................................................8G enera l Informa tion............................................................................................................. 8

    Functions of the Touchpads..............................................................................................10

    Entry/Exit Delays.................................................................................................................12Exit Dela y ........................................................................................................................... 12En try Dela y......................................................................................................................... 12Exit Ala rms ......................................................................................................................... 13

    Checking For Open Zones..................................................................................................13Using the [ ] Key ................................................................................................................ 13

    Arming the System ..............................................................................................................14St a y Mode: Arms P erimeter Only, Ent ry Dela y On......................................................... 14Night -St ay M ode: Arms P erimeter Only, P lus Selected Zones ....................................... 14Inst a nt Mode: Arms P erimeter Only, Entr y Delay Off.................................................... 14Awa y Mode: Arms E nt ire Syst em, Ent ry Dela y On......................................................... 14Arming Comma nds............................................................................................................. 15Sing le B utt on Armin g ........................................................................................................ 16Sing le-B utt on St ep Arming ............................................................................................. 16

    Using the Keyswitch............................................................................................................17U sing the Keysw itch .......................................................................................................... 17

    Disarming and Silencing Alarms .....................................................................................18U sing the [OFF ] key........................................................................................................... 18

    Bypassing Protection Zones..............................................................................................19U sing t he B YP ASS Key ..................................................................................................... 19Quick B ypa ss ...................................................................................................................... 20

    Chime Mode...........................................................................................................................20

    Viewing Current Date and Time......................................................................................21Viewin g t he C urrent Da te a nd Time................................................................................. 21Set ting the Da te a nd Time................................................................................................. 21

    Panic Keys .............................................................................................................................22U sing P a nic Keys................................................................................................................ 22

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    4/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    5/56

    5

    Congrat ulations on your ownership of a n ADT P ar titioned S ecurity S ystem. You'vemade a wise decision in choosing it, for it represents the latest in security protectiontechnology t oday, a nd millions of premises a re protected by ADT syst ems.

    This sy stem provides: Three forms of protection: bur glar y, fire* a nd emerg ency. At least one touchpad which provides control of system operation and displays

    the systems status Various sensors for perimeter a nd int erior burglar y protection Sm oke or combustion detectors* designed to provide early w a rning in case of fire.

    Your system ma y a lso ha ve been program med to automat ically send ala rm or sta tusmessages over th e phone lines to a Cust omer Ca re Center.* Comm ercial in stal l at ions and some resid enti al systems m ay not i nclude fir e pr otection check w it h your in stall er.

    Burglary Protection

    There are four modes of burglary protection: St ay, Night-St ay , Awa y, Inst an t.STAY: ar ms perimeter zones only and entry delay is onINS TANT: sa me a s S TAY, except ent ry delay is offNIG HT-STAY: a rms perimeter zones an d selected interior zones; entry dela y onAWAY: ar ms perimeter a nd a ll interior zones, ent ry dela y is on

    You can B YPASS selected zones w hile leaving th e rest of the system a rmed. CH IME mode alerts you to the opening of protected doors a nd w indows wh ile thesystem is disarmed.

    Fire Protection Fire protection is a lwa ys a ctive (if installed) an d a n a larm sounds if a fire

    condit ion is det ected If necessary, you can m anu ally initiat e a fire alarm us ing the touchpad. Refer to the Fire Alarm System section for information regarding fire protection,

    smoke detectors and planning emergency exit routes.

    Security Codes You were assigned a 4-digit security code during system installation. Use your security code when a rming a nd disarm ing the system, and w hen

    performing other system functions. Other users can be assigned different security codes. User codes can be a ssigned different a uthority levels, wh ich define wh ich syst em

    functions a part icular user can perform.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    6/56

    6

    Zones and Partitions

    The system sensing devices have been assigned to various zones, which arespecific area s of protection (e.g., front door, kitchen w indow, etc.).

    Zone numbers are displayed a t t he touchpad w hen an ala rm or trouble conditionoccurs on a sensor.

    P ar titions provide two independent a reas of protection, w ith ea ch partit ionconta ining a group of zones tha t can be a rmed an d disarm ed without a ffectingother zones or users.

    P ar titioned systems can include a common zone ar ea, which is an a rea sha red byusers of both par tit ions (such a s a lobby in a building ).

    P art ition identificat ion: 1 = part ition 1; 2 = partit ion 2; 3 = common zone.

    Arming, Step-Arming and Disarming Burglary Protection The system must be armed before the burglary protection; can sense intrusions. To arm y our system , enter your user code followed by th e desired arm ing key. You can also use the step-ar ming key to a rm t he system, if programmed. To disar m t he syst em, enter y our user code then press th e [OFF] key. Step-ar ming, if progra mmed, lets you use a function key to arm the syst em in one

    of three modes by simply pressing the key repeatedly, where:first press a rms S TAY; second press a rms N IG HT-STAY; third press ar msAWAY.

    Alarms When an ala rm occurs, both t he touchpad an d external sounders will sound, a nd

    the touchpad w ill display t he zone(s) causing th e ala rm. If your system is connected to a Cust omer Ca re Center, an a larm m essage will

    also be sent. To stop the ala rm sounding, simply disarm the syst em.

    Memory of Alarm When an alarm condition occurs, the touchpad displays the number(s) of the

    zone(s) that caused the problem, an d displays t he type of alarm . The message rema ins display ed even a fter disarm ing the system, but can be

    cleared with another off sequence.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    7/56

    7

    Phone Access If included, a phone module permits you to access the syst em via a t ouch-tone

    phone, either on-premises or by call-in w hen a w ay . You can r eceive synth esized voice messa ges over th e telephone rega rding t he

    sta tus of the security syst em. You can a rm a nd disa rm th e system an d perform most function comma nds

    remotely via the telephone, with voice confirmation provided after each commandentry.

    Complete informa tion regarding t he use of this feature is provided in a separa teman ual entit led Phone Access User 's Guide th at is supplied with the voice

    module.Paging Feature

    If programmed, up to four pagers can aut omatically display certain syst emcondit ions as t hey occur in your syst em.

    The display consists of code numbers that indicate the type of condition that hasoccurred.

    Function Keys The A, B , C, an d D keys on the touchpa d can be progra mmed to perform

    various functions. Functions include: activate a P an ic ala rm; ar m the system; provide step arming;

    sw itch lights on/off; send a messa ge to a pa ger; display Time/Da te; st a rt a Ma cro

    Scheduling Your system can be programmed to automatically perform certain functions (e.g.,arm the system) at a predetermined time each day.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    8/56

    8

    Your touchpads allow you to control all system functions. The touchpads feature thefollowing: A telephone st yle (digital) keypad Liquid Crysta l Display (LCD ) wh ich shows the na ture an d location of all

    occurrences B uilt-in sounder which will sound during a larm s a nd t roubles. The sounder a lso

    "beeps" during certain syst em functions a nd w hen depressing any of the keys (toa cknow ledge the key press).

    Ba cklighting of the LCD d isplay w indows. B acklighting turns on when entering the

    premises through a ny a ssigned entr y/exit door, or when a ny t ouchpa d key ispressed. This featur e is helpful when a touchpad is located in a dimly lit a rea.

    IMPORTANT: If the touchpad beeps rapidly upon entering the premises, it indicat estha t a n ala rm ha s occurred during your absence and a n intruder may st il l be on thepremises. LEAVE IM MED IATEL Y and C ONTACT THE P OLICE from a nea rby sa felocation.

    There are tw o basic types of touchpads wh ich a re functionally t he sam e, but theyha ve different t ypes of displays.

    Custom En glish Display 2-line Custom E nglish display touchpad s feature a 2-line,32-chara cter alphanum eric LCD which can display systemmessages in friendly English. These touchpads can also beprogram med w ith cust om zone descriptors. To access thekeys on the touchpad, sim ply open the sw ing-down d oor.

    E n glish Dis pla y E n glis h d ispla y tou ch pa d s a r e fu nct ion a lly id en tica l t oCustom En glish display touchpad s, but the LCD displayuses pre-designated w ords to identify t he na ture a ndloca tion of occurrences. To access the keys on t he t ouchpa d,simply open the sw ing-down d oor.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    9/56

    9

    AWAY: All burglary zones, interior andperimeter, are a rmed.

    STAY: P erimeter burglary zones, such a sprotected windows a nd doors, a rearmed.

    INSTANT: P erimeter burglary zones armedan d entry delay is tur ned off.

    ALARMFIRE

    AWAYBYPASS

    STAYCHECK INSTANT

    NO ACTEST

    NOT READYCHIME BAT

    ENGLISH DISPLAY TOUCHPAD

    BYPASS: This a ppears w hen one or more burgla ry protection zones ha ve beenbypassed.

    NOT READY: Appears wh en burglary portion of the syst em is not ready for a rming(due to open protection zones). The syst em is rea dy t o arm wh en th ismessage disappears a nd th e READY indicat or light comes on.

    NO AC: Appears when AC power has been cut off. System is operating onbackup batt ery power.

    AC: Appears w hen AC power is present.

    CHIME: Appear s when the CH IME feat ure is activa ted.

    BAT: Low battery condition in a wireless sensor (if zone number displayed)or low s ystem b at tery (if no zone number display ed).

    ALARM: Appears w hen an intrusion has been detected an d the system is a rmed(also appears during a fire alarm or audible emergency a larm).Accompanied by t he protection zone in a lar m.

    CHECK: Appear s wh en a ma lfunction is discovered in the system a t a ny t ime orif an open is detected in a F IRE zone at an y time or a fa ult in aDAY/NIG H T burgla ry zone dur ing a disa rmed period. Accompanied bya display of zone number in trouble.

    FIRE : Appears wh en a fire alarm is present. Accompanied by a display of thezone in alarm .

    A FIRE display, a ccompan ied by a display of zone 95, also a ppear swhen a f i re a larm is manua l ly ac t iva ted .

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    10/56

    10

    1. DISPLAY WINDOW.

    C u st o m E n g l i s h D i sp l a y To u c h p a d s: 2-line, 32-chara cter Liquid Cryst al D isplay(LCD ) touchpads th at display protection pointidentifica t ion, system sta tus, a nd messages.E n g l i s h D i s p l a y To u c h p a d s: Displayprotection zone ID and system sta tusmessages using pre-designat ed words in theLCD display.

    2. 1 OFF Disa rms burgla ry portion of t he

    system, silences ala rms and aud ible trouble

    indicat ors, and c lears visual display a f terproblem's correction.

    3. 2 AWAY Arms the entire burglary system,

    perimeter and interior.

    4. 3 STAY Arms perimeter portion of burgla ry

    system only. Int erior protection is not armed, allowing movement wit hin premiseswithout causing an a lar m.

    5. 4 This is not a Function key. Used

    only as a n umeric key.

    6. 5 TEST Tests the system and a larm

    sounder if disar med. Refer to Testi ng The System section for test procedures.

    7. 6 BYPASS Removes individua l protection

    zones from being monitored by the system.

    8. 7INSTANT Arms in ma nner similar to the

    STAY mode, but w ithout th e entry dela yfeat ure. Ent ering via a n entry /exit door w illcause an ins tan t a la rm.

    9. 8 CODE Used to a ssign addit ional user

    codes for other users of t he syst em.

    10. 9 CHIME Turns C HI ME mode on and off .

    When on, th e opening of win dows or doorswh ile the system is disarmed will sound 3beeps a t t he touchpad(s).

    11. READY Used to display all open protection

    zones.

    12. This key ca n be used for " Quick

    Arming" of the system wit hout use of asecurity code (if programmed).

    13. KEYS 09 : Used to enter your securitycode(s).

    14. READY INDICATOR: (GREEN) Lit whenthe system is read y to be ar med (no fault spresent). While the syst em is disa rmed, t hisindicator w ill go on a nd off as protectionzones are closed and opened.

    15. ARMED INDICATOR: (RED ) Lit w hen thesystem has been armed.

    16. INTERNAL SOUNDER: The b uilt -in

    sounder mimics the alarm sounder duringala rms, and w ill a lso "beep" dur ing cer ta insystem functions.

    17. FUNCTION KEYS: Keys A, B, C, D ma yha ve been progra mmed for a var iety offunctions, including pa nic (emergency)functions. For details, see the Fu nction Keys section.

    Note: Keys 1 OFF through 3 STAY a n d 2 AWAY through 7INSTANT each perform theirassociated compa nion sy stem functions (OFF, S TAY, AWAY, INSTANT, et c.) w henpreceded by a n ent ry of the security code (as described lat er).

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    11/56

    11

    ARMED READY

    6 BYPASS

    7 INSTANT

    1 OFF AWAY STAY2 3

    4 TEST

    CODE CHIME

    READY

    98

    5

    #0

    A

    C

    D

    B

    1

    4

    32

    17

    5

    18

    8

    11

    15

    14

    16

    6

    7

    9

    10

    12

    13

    English Display Touchpad

    ARMED READY

    6 BYPASS

    7 INSTANT

    1 OFF AWAY STAY2 3

    4 TEST

    CODE CHIME

    READY

    98

    5

    #0

    A

    C

    D

    B

    KEYPAD SHOWN WITHOUT SWING-DOWN FRONT DOOR

    1

    4

    3

    2

    17

    5

    18

    8

    11

    15

    14

    16

    6

    7

    9

    10

    12

    13

    Custom English Display Touchpad

    (Touchpads shown without swing-down front door)

    IMPORTANT! When entering codes an d commands, sequential key depressions must be mad e

    wit hin 10 seconds of one another. I f 10 seconds ela pse with out a keydepression, the entr y w ill be aborted a nd mu st be repeated from its beginning.Be sure to observe this precaution when performing any of the procedures inth is manual .

    If you make a mistake wh ile enter ing a security code, stop, press the [ ] key,and then s tar t over. If you stop in the middle wh ile entering a code, and thenimmediately sta rt the entry over, a n erroneous code might be entered.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    12/56

    12

    Your system ha s preset time delays, known a s exit delay a nd entry delay .

    Exit delay gives you time to leave through the designat ed exit door without sett ingoff an a larm. E xit delay begins immediately after a rming your system in anyarm ing mode and C ustom Display touchpads display th e message You May ExitNow. When You may exit now disa ppear s, the system is fully ar med. If programmed, aslow beeping will sound throughout the exit delay period.

    Exit Delay Restart. If you w ish to open the entry /exit door to let someone in aft er a rmingSTAY, you can re-sta rt the exit delay a t a ny t ime simply press the [ ] key , then let tha tperson in. This avoids having to disar m the system a nd then re-ar m it a gain.

    En try D elays give you time to disarm t he system wh en you re-enter through thedesignated entra nce door. B ut you must disa rm t he system before the entry delayperiod ends, or an a lar m w ill occur. The touchpad beeps during th e ent ry delayperiod, reminding you to disarm the system. There are two entry delays (ifprogram med). The first is for your prima ry ent ra nce and t he second ca n be used fora secondary entra nce, where a longer delay is required to wa lk to the touchpad t odisarm the sys tem.

    You can a lso arm the system w ith no entry delay a t a ll by using the INSTANTa rming m ode. This mode provides grea ter security w hile on th e premises or w hileaway for extended periods of time.

    See your installer for your delay times.

    Partition 1 __________________________________________________________

    E xit D ela y: seconds E nt ry D ela y 1: seconds

    En try Delay 2: seconds

    NOTE: En try /Exit tim es set for part ition 1 also apply to the common zone.

    Partition 2 __________________________________________________________

    E xit D ela y: seconds E nt ry D ela y 1: seconds

    En try Delay 2: seconds

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    13/56

    13

    Whenever you a rm t he syst em, th e exit delay begins. I f a n ent ry/exit door or interiorzone is fault ed wh en th e exit delay end s (e.g., exit door left open), the sy stem soundsan a larm a nd sta rts t he entry delay timer. If you disarm th e system before the entrydelay ends, the alarm sound stops and th e message "CANCEL ED ALARM" or "C A" isdisplay ed on th e touchpad, a long w ith a zone number indica ting th e faulted zone. Nomessage is sent t o the Cust omer Ca re Center.

    To clear the exit alarm condition, the open zone must be made inta ct; to clear thedisplay , enter your code plus OFF.

    If you do not disar m th e system before the entr y delay ends, a nd a n entr y/exit door orinterior zone is still open, the a larm sound continues a nd a n " exit a larm " m essage issent to the Cu stomer Ca re Center. The message " "E XIT ALARM" or "E A" is display edon the touchpad, along wit h a zone number indicating the fa ulted zone. To stop theala rm, t he system m ust be disa rmed (your code plus OFF); to clear the display, enteryour code plus OFF a second t ime.An exit ala rm a lso results if an ent ry/exit door or interior zone is fault ed wit hin tw ominutes a fter the end of the exit delay.

    Your system may have been programmed for this feature to minimize false alarms sent to the CustomerCare Center. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.

    Before arming your system, all protected doors, windows and other protection zonesmust be closed or bypassed, otherwise the touchpad will display a "Not Rea dy"message.

    Use the READY key to display all fa ulted zones, ma king it ea sier for you to identifyand secure any open zone.

    1. P r es s [ ] (do not enter code first) to display fau ltedzones .

    2. Secure or bypass the zones displayed.3. The touchpads READY indicator lights when allprotection zones ha ve been either closed or bypa ssed.

    4 . Arm the sys tem as des ired .

    Custom Display:

    English Display:Zone no. and NOT READY

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    14/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    15/56

    15

    Before arm in g, close all per im eter door s and w in dows and m ake sur e th e Ready t o Arm m essage is d i splayed.

    Mode Press these keys Touchpad Confirms BySt a y secur it y code + [3] (S TAY) th ree beeps

    ar med S TAY message displa yed red ARMED indicat or lights

    N ig h t -S t a y s ecu r it y cod e + [3] + [3 ] th ree beeps NIGHT-STAY message displayed

    red ARMED indicat or lightsI nst a nt secu rit y cod e + [7] (I NS TANT) th ree beeps

    ar med S TAY message displa yed red ARMED indicat or lightsNote tha t entry delay is turned off .

    Aw ay secur ity code + [2] (AWAY) beeping for dur at ion of exit delay a rmed AWAY messag e displayed red ARMED indicat or lightsLeave t he premises thr ough a n ent ry/exitdoor during the exit delay period to a voidcausing a n a larm . The touchpad beepsra pidly during th e last 5 seconds of theexit de lay to wa rn you that i t is ending.

    Quick ArmingIf "Quick Arming" was programmed by the installer, the [#] key can be pressed inplace of the security code when arming the system. However, the security codemust always be used to disarm the system.

    Function Key ArmingFor any arm ing command, a function key ma y ha ve a lso been programmed for your system. I fso, you can press and hold the appropriate function key for 2 seconds to arm the system. Seeyour insta ller for th e designat ed functions (see S i n g l e B u t t o n A r m i n g section).

    Refer to the A c cessi n g O t h e r P a r t i t i o n s section for information on multi-partiion

    arming.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    16/56

    16

    The A, B , C, a nd/or D keys on your touchpad m ay ha ve been progra mmed forsingle-button a rming. Note tha t w hile it will not be necessary to use a security codefor a rming, a security code must a lwa ys be used to disarm the system.

    If S ingle-B utton Arming is progra mmed: A function key ha s been a ssigned t o a specific type of arm ing: S TAY mode,

    Nigh t-STAY mode, AWAY mode, or S TE P -ARMIN G (see Step-Arm ingparagraph).

    You D O NOT need to ent er your u ser code before pressing th e function key(you always need your user code to DISARM the system).

    Before arm in g, close all per im eter door s and w in dows.

    1. P ress and hold the assigned function key for 2seconds (no code is r equired). Function keys a reshown below.

    321

    654

    987

    #0*READYINSTANT

    OFF

    CODE

    AWAY

    TEST

    CHECK

    STAY

    BYPASS

    A

    B

    C

    DADT3000-007-V0

    English Display: READY

    2. The touchpad begins beeping and displays thearm ed message. The red ARMED indicat or also

    lights.

    English Display: AWAY

    Single-B utton S tep arm ing ma y ha ve been programmed int o one of the lettered keys(A, B, C, or D). Check with your installer to see if this has been done in your system.

    If Step-Arming is programmed: The a ssigned key provides a choice of t hree levels of security . The selected key ca n be pressed once, tw ice, or thr ee times, increa sing t he level

    of security with each press, as follows

    Key First Press Second Press Third Press

    A, B , C, D Ar med -S TAY Ar med N igh t-S TAY Ar med -AWAY

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    17/56

    17

    Your system ma y be equipped with a keyswitch for use when a rming a nd disarm ing.Red and green lights on the keyswitch plat e indicat e the sta tus of your system a sfollows:Green Light: Lights w hen the system is disarmed and ready to be arm ed (no

    open zones). If the system is disarmed and the green light is off, itindicat es the sys tem is not r eady (one or more zones are open).

    Red Light: Light s or flash es w hen sys tem is a rmed in AWAY or STAY mode.See your installer for the meanings of the lit red light:

    L it S teady = system a rmed AWAY or

    system armed STAY and exit delay has expired

    F la s h in g = s ys t em a r m ed S TAY a n d ex it del a y t im er a ct iv e

    Rapid flashing = an a larm ha s occurred (memory of alar m).

    Before arm in g, close all per im eter door s and w in dows.

    To arm in the AWAY mode:Turn the key to th e right for 1/2 second a nd release.Touchpa ds beep twice and th e red indicator light s orflashes.

    To arm in the STAY mode:Turn t he key to the right and hold for longer tha n 1second, t hen r elease. Touchpa ds beep thr ee timesan d the red indicator lights or flashes.

    To disarm the system:Turn t he key to the right a nd releas e. The red lightturns off

    GREEN RED

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    18/56

    18

    The OFF key is used to disarm t he system, silence alarm a nd trouble sounds, an dclear a larm memories.

    IMPORTANT : If you return and the main burglary sounder is on, DO N OT ENTER, butCONTACT THE P OLICE from a nearby safe locat ion.If you return after an alarm has occurred and the main sounder has shut itself off , the touchpadwill beep rapidly upon your entering, indicating that an alarm has occurred during yourabsence.LEAVE AT ONCE, and CONTACT THE POLICE from a nearby safe location.

    1. + 1

    (Security Code) OFF

    The RE ADY ind icator light will be lit if a ll zonesare secure, and the touchpad will emit a single toneto confirm tha t th e system is disar med.

    English Display:

    2. To Silence a Burglary Alarm and Clear a Memory of Alarm Ent er your security code and press the OFF key tosilence the alarm (or warning tones of a Memory ofAlarm).Note the zone in ala rm on the touchpad display, a ndma ke tha t zone inta ct (close door, wind ow, etc.). Now enter t he security code plus OFF sequ ence again t oclear the touchpads Memory of Alarm display.Note the zone in ala rm on the touchpad display, a ndma ke tha t zone inta ct (close door, wind ow, etc.). Now enter t he security code plus OFF sequ ence again t oclear the touchpads Memory of Alarm display.

    3. To Silence a Fire Alarm and Clear Memory of Alarm Simply press the OFF key to silence th e ala rm. Thenenter the security code plus OFF sequence to clearthe touchpad's Memory of Alarm display . See theFir e Alar m System section.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    19/56

    19

    U se t his key w hen you wan t to a rm your system w ith one or more zones intentiona llyunprotected. The system must be disarmed first.

    When bypa ssing zones: Your system m ay ha ve been set so tha t a rming w ill not be possible if more tha n

    one zone is bypa ssed (check with your inst a ller). The system must be disarmed before you can bypass zones. B ypassed zones ar e unprotected and w ill not cause a n a larm if violat ed. The syst em w ill not allow fire zones to be bypassed. Zones are aut omatically unbypassed wh en the system is disar med.

    1. + 6 + zone numbers (see below)

    (Security Code) BYPASS

    Enter the 2-digit zone number(s) for the zone(s) to bebypassed (e.g., 06, 10, 13, etc.). Single digit zonenum bers mu st be preceded by a zero (e.g. 05, 06).

    English Display:NOT READY

    2. When finished, the touchpad will momentarilydisplay a "B ypass" message for each bypassed zonenumber. Wait for all bypassed zones to be displayed.Arm the system a s usual.To displa y bypa ssed zones prior to a rmin g, enteryour security code a nd press th e [6] B YP ASS key.

    English Display: BYPASS

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    20/56

    20

    If programmed, "Quick Bypass" allows you to easily bypass all open (faulted) zoneswithout having to enter zone numbers individually. This feature is useful if, forexample, you routinely leave certain w indows open when a rming a t night .

    1. + 6 + [#]

    (Security Code) BYPASS

    In a few moments, a ll open zones w ill be displayedand automatica l ly bypassed . Make sure tha t only thosezones tha t you wish to leave unprotected a re bypassed, andtha t th ere are no other zones unintentionally left open.

    English Display:NOT READY

    2. Wait for a ll bypassed zones to be displayed, then a rmthe system a s desired.

    English Display: BYPASS

    Ask your insta ller if "Quick B ypas s" is active for your system, a nd if so, check here:

    CH IME mode alerts you to the opening of a perimeter door or window wh ile thesystem is disarmed.

    When Ch ime mode is activat ed: Three tones sound a t t he touchpad w henever a perimeter door or window is opened. Interior zones do not produce a tone when t hey a re faulted. Pressing the READY key will displa y t he open protection points. Chime mode can be used only while the system is disa rmed.

    To turn Chime Mode on: + 9

    (Security Code) CHIME

    The CH IME message w ill appear. P erimeter zoneswill cau se a tone when fa ulted.

    English Display: READY

    To turn Chime Mode off:

    + 9 a ga in

    (Security Code) CHIME

    The CH IME message will disappear.

    English Display: CHIME

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    21/56

    21

    The system lets you view its time a nd da te setting.

    + [#] + [6] [3]

    (Security Code)

    OR, press t he function key (A, B , C, or D ) for viewingcurrent dat e and t ime, if progra mmed.

    English Display: READY

    A ty pica l time/da te displa y is sh own.The display w ill remain on for about 30 seconds.

    A B C D

    If one of the a bove keys ha s been program med for th e da te/timedisplay feature, place a check mar k in the box beneath t ha t key.

    You can set t he time an d da te by doing the following:

    1. + [# ] + [6] [3]

    (Security Code)

    2. P r es s [ ] wh en th e time/da te is displa yed.A cursor appears under the first digit of the hour.To m ove cur sor ah ead , pr ess [ ] . T o go ba ck , pr ess [#] . E nter t he 2-digit hour setting. En ter the 2-digit minute sett ing. P ress [1] for P M or [2] for AM. Ent er the last tw o digits of the current year. En ter the 2-digit month sett ing. Ent er the 2-digit day setting.

    3. To exit, press [ ] wh en cursor is a t t he last digit , orwait 10 seconds.

    Current time display

    Time/date editing display

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    22/56

    22

    Your system m ay h ave been programmed to use special keys to manua lly activateemergency (pan ic) functions a s follow s:

    This Function Sends this signal* With This SoundingS ilen t Ala rm silen t a la rm n o a udible a la rm or a ny visu al displa y

    indica t ing tha t a s i len t a la rm ha s beeninitiated.

    Audible Ala rm a udible a la rm a loud, s tea dy a la rm a t touchpa d(s)and a t a ny external sounders tha tma y be connected.

    P ersona l Ala rm emergency a la rm stea dy a la rm sound a t touchpa d(s),but not a t external bells or sirens.

    F ire Ala rm fire a la rm t empora l (pulsing) sound a t ext erna lbells an d sirens.

    *All panic functions send signals to the Customer Care Center, if connected.

    To active a Panic Function:P ress and hold down for a t least 2 seconds whicheverlettered key on the touchpad has been programmed forth e desired emergency function.

    OR

    P ress both keys of the assigned key pair a t th e sametime.

    English Display: READY

    Typical Panic Display:

    English Display:99 and ALARM

    321

    654

    987

    #0* READYINSTANT

    OFF

    CODE

    AWAY

    TEST

    CHECK

    STAY

    BYPASS

    READYARMED

    ABCD

    6139-001-V0

    321

    654

    987

    #0*READYINSTANT

    OFF

    CODE

    AWAY

    TEST

    CHECK

    STAY

    BYPASS

    READYARMED

    6139ADT-002-V0

    PRESS BOTH KEYSOF DESIRED PAIRAT THE SAME TIME

    ZONE 95

    ZONE 99

    ZONE 96

    Lettered Panic Keys Panic Key Pairs

    See your insta ller a nd use the char t provided in the F ea t u r es P r o gr a m m e d i n Yo u r System section t o note th e functions th at ha ve been programmed for your system.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    23/56

    23

    The A, B , C or D keys can be used to a utomat ically a ctivate a series ofcomma nds of up to 16 keystr okes, if program med for th is function. These keystrokes,as a group, are called macros and are st ored in th e system's memory.

    Typical m a cro functions ca n include:- Arming sequences: STAY, Night-STAY, INSTANT, or AWAY- Bypassing particular zone(s)- Activa ting relay (s) for t urnin g on (or off) lights, fan s, etc.

    Up t o four ma cros can be a ssigned but no more tha n one macro to a key. Macros can be activated only by users with a uthority levels aut horized to

    perform t he ma cros function. Macros function only w hen the system is disa rmed.

    NOTE: The installer must activate the desired function key (using *57 Function keyMenu Mode) before ma cros ca n be a ssigned.

    See the chart a t t he back of this ma nua l for th e key(s) assigned for macros.

    1. + [#] + [6] + [6]

    (Security Code)

    2. Enter the macro number, 1-4, to be programmed atthe S elect Ma cro? prompt. Remember, there ar efour ma cros a vaila ble, but only one macro can be

    assigned t o each key.

    3. If a m acro has been previously defined, thekeystrokes ar e shown on the bottom line of thedisplay, otherw ise the display is blank.

    To exit th is mode (an d keep the existing ma crodefinition), press an y key except th e [ ] key. Thesystem returns to normal mode.To define a ma cro for t he selected key, press [ ] a ndcontinue w ith t he next prompt.

    Enter the first of the series of desired commands, (donot include your user code wh en progra mmin g a

    ma cro), then press/hold the D key for a t lea st t woseconds t o complete t he first comma nd. This keyterminates each separate command, and appears asan F in the touchpad display.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    24/56

    24

    The touchpad beep to acknowledge your input a nddisplay s th e comma nd you entered (follow ed by F).

    4. Ent er the n ext comma nd, followed by press/holdingthe D key for at least tw o seconds. The touchpadbeeps and displays the keystrokes entered so far.

    5. Repeat until the all the desired comma nds (up to 16chara cters including th e Fs) have been entered .B e sure to check your keystrokes before contin uing.If you made a mista ke, you must star t over.

    6. To exit, press/hold the D key for at lea st t w oseconds. The display returns t o system sta tus a ndindicat es system is ready .

    Typical Macro Display:

    #

    Suppose you wa nt to (1) bypass t he tw o upstairs w indow zones, then (2) turn on anexterior light, a nd t hen (3) a rm the security syst em in t he AWAY mode. Theprocedures in th e ta ble that follows show you how you w ould program t his ma cro:

    Function Keystrokes Required Touchpad Display

    1. B ypa ss zones 02 & 03 Press BYPASS [6] key, then2-digit zone nu mbers 02 & 03.

    2. Inser t te rminator. P ress the D key for at least 2 seconds. 3. Turn light on (dev ice 01).

    P ress [#] and 7 keys for device ON, an d

    [01] key for selecting device 1. #

    4. Inser t te rminator. P ress the D key for at least 2 seconds. # 5. Arm system AWAY Press AWAY [2] key. # 6. Inser t te rminator. P ress the D key for at least 2 seconds. #

    System m ust be di sarm ed before perf orm in g a macro fun ction.

    1. P ress the Ma cro key progra mmed for the desiredseries of comma nds for a t lea st 2 seconds. The EnterUser Code prompt appears. The prompt rema insdisplay ed for up t o 10 seconds.

    2. En ter y our 4-digit u ser code.The program med ma cro sequence beginsaut omatically a fter the user code is entered.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    25/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    26/56

    26

    Your system ma y be set up to automat ically send alert messa ges to a pa ger as certa incondit ions occur in y our syst em.

    The following events can be programmed by your installer to send a message toup to four pagers: a rming, disarm ing, ala rms, a nd trouble conditions.

    You can a lso program th e system to send an a utomat ic pager messa ge to alertyou in the event t ha t someone ha s not a rrived home (disarm ed the system)wit hin a defined period of time (see the S c h e d u l i n g section for deta ils onprogram ming a latch key report).

    Your inst aller progra ms t he pager phone numbers a nd reporting events.

    The pager message consists of a 7-digit system sta tus code that indicat es thetype of condition that has occurred. An optional, predefined 16-digit cha ra cter str ing can precede the 7-digit sy stem

    status code; these characters can consist of a PIN no., subscriber account no., orany a ddi t ional da ta tha t you may w ish to have sent to the pager.

    The pager display format is as follows: 3-digit Event Code

    Optional 16 digits AAAAAAAAAAAAAAAA BBB CCCC 4-digit User or Zone No.

    A = B = C =Optional 16-digits forAccount numbers,P IN numbers, or anyother data;programmed by t heinstaller, if required.

    A 3-digit code thatdescribes the eventtha t ha s occurredin your system(see for eventcodes ta ble below)

    A 4-digit U ser or Zone number, depending on t he ty pe ofevent that has occurred, where: alarms and troubles display zone number a rmin g/disa rmin g (opens/closes) displa y us er num berThe first 2 digits a re a lwa ys 00 (e.g., 00 04 representszone or user num ber 4), a nd, single-digit us er or zonenumbers are a lways preceded by a zero.

    The 3-digit Event Codes (B B B ) that can be displayed a re:911 = 811 = 101 = 102 =Alarms.

    The 4-digit num ber(CCCC) following thiscode is the zone nu m ber tha t has caused thea larm.

    Troubles.The 4-digit num ber(CC CC) following t hiscode is the zone nu m ber tha t has caused thetrouble.

    Open(system disarmed).

    The 4-digit nu mber(CCCC) that followsthis code is the user number t h a t ha sdisarmed the system.

    Close(system armed).

    The 4-digit num ber(CCCC) that followsthis code is the user number tha t has a rmedthe system.

    Exa mples of typical 7-digit pa ger displa ys follow.Ex. 1 . = R eporting of an a larm (911) caused by a fault on zone 4 (00 04 ).

    Ex. 2. = Reporting of a closingsystem a rming (102) by user 5 (00 05 ).

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    27/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    28/56

    28

    Your sys tem lets y ou assign u p to 45 different s ecurity codes for use by other u sers. Only the Mast er user or P art ition P rogrammer can a ssign user codes to users. U sers a re identified by 2-digit us er numbers 03-49 an d a re pre-as signed to

    either pa rtit ion 1 or pa rt ition 2 (users 01-02 are reserved). Only the Insta ller or Master can cha nge the partit ions to which a u ser is assigned. In a ddition to a security code, each user is assigned va rious system a ttr ibutes. User codes can be used interchangea bly within a part ition when performing

    system functions (a system a rmed w ith one user 's code can be disa rmed bya nother u ser's code), w ith t he exception of the guest code described below.

    User code programming involves these steps:- First, choose a u ser number from the set of users a ssigned to the part ition in

    which the user will be operating, and assign a 4-digit security code.- Second, ass ign an author ty level to tha t user.- La stly, assign other at tributes as necessary (see at tributes on the next page).

    Auth ority levels define the syst em functions a pa rt icular us er can/cann ot perform.Auth ority level ca tegories are a s follows:

    Level Title Explanationuser Ma st er C a n per for m a ll sy st em fun ct ion s a nd a ssign cod es in bot h02 pa r t it ions; ca n cha nge it s ow n code a s follow s:

    Master code + [8] + 02 + new master code + new master code again(0) S tanda rd : Can on ly per form secu r ity funct ions in a s s igned pa r t it ion .

    U ser C a nnot perform other syst em funct ions.(1) Arm On ly : Can on ly a rm the system. Canno t d i sa rm or do othe r funct ions .(2) G u es t: C a n a r m t he sy st em in a s sig ned pa r tit ion s, bu t ca n not d is ar m

    the system unless the system w as a rmed with this code. Thiscode is typically assigned to someone (such as a babysitter orcleaner) who has a need to arm/disarm the syst em only atcerta in t imes. The user of th is code should not use th e QuickArming fea ture.

    (3) Duress Code: Int ended for use wh en you are forced to disarm or ar m thesystem under thr eat. When used, the system will act norma lly,

    but can silently n otify the C ustomer Ca re Center of yoursitua tion, if that service has been provided.

    (4) P ar tition Ca n do everything a sta nda rd user can do, an d can assign Programmer user codes to users in the ir par t i t ion .

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    29/56

    29

    The following lists the va rious comma nd st rings for add ing user codes and a ttributes.Refer to the User S etup cha rt a t t he back of this ma nua l for factory assignment s of userat tributes a nd t o keep a record of user program ming.

    NOTE: P art ition P rogrammer code can be used only for user numbers a ssigned to thatprogram mer s partit ion.

    Add User Code: Master/Part. Prog.code + [8] + user no. + new users code(Users 03/33 are preset U s er 01 = i n st a ll er U s er 03 = p a r t it ion 1 pr og ra m m erto partition programmers, U ser 02 = m a st er U ser 33 = p a rt it ion 2 pr ogr am merbut can be changed.) The Touchpad beeps once to confirm tha t n ew user wa s a dded.

    Delete User Code: Master/Part. Prog. code + [8] + [user no.] + [#] [0]The user code and all a tt ributes* program med for this user number,including any a ssociat ed RF keys, are erased from the system.(*except a ssigned par tition)

    Authority Level: Master/Part. Prog. code + [8] + [user no.] + [#] [1]+ auth. levelAuthority Levels (see definitions on previous page):0 = stan dard user 3 = duress1 = arm only 4 = par t i t ion programmer2 = guest

    Access Group: Master/Part. Prog. Code + [8] + [user no.] + [#] [2]+ group (1-8)You can a ssign users to a group, then set an a ccess schedule tha tdefines the tim es this gr oup of users can operat e the syst em. Thesystem ignores these users outside the scheduled times.

    Users Partition: Master Code + [8] + [user no.] + [#] [3]+ partition(s) + [#] (to end)Factory Assignments: Use t his comma nd t o assign the par t i t ions the user can access. EnterPart. 1 = users 03-32 part ition numbers sequentia lly, then press [#] to end the entry .Part. 2 = users 33-49 Users can operat e any combination of part itions desired.

    Pa r t i t ion Numbers:0 = c lea r s pa r t . 1 a n d pa r t . 2 a s si gn m en t s 2 = p a r t it ion 21 = pa r t it ion 1 3 = com mon pa r t it ion

    RF User Number: Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.Use t his comma nd t o assign a wireless button device (keyfob) to thisuser (keyfob must be enrolled in system first; see insta ller).Zone number: enter the zone number assigned to a butt on on the

    keyfob tha t w ill be used for arming /disar ming by t his user.Pager On/Off: Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1

    You can program a user so tha t a message is sent to a pa gerwh enever this code is used to ar m or disarm the system.P agin g On/Off: 1 = allow pa ging; 0 = no paging for th is user

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    30/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    31/56

    31

    If t he user is au thorized, a touchpad in one par tition can be used to perform syst emfunctions in t he other partition by using the GOTO command.

    You must use a C ustom En glish touchpad t o access another part ition. Touchpads a utomat ically return t o their original pa rtition aft er 2 minutes

    with n o touchpad activity.

    1. + [ ] + par tit ion number (0,1,2,3)

    (Security Code)

    0 = return t o touchpads original pa rtition.

    1 = part ition 1; 2 = part ition 2; 3 = common zoneThe touchpad beeps to confirm th e part ition chan ge.

    English Display: READY

    2. The touchpad r emains in t he new par tition untildirected to go to an other part ition, or unt il itaut omatically returns to the original part ition.The active partition number is displayed in the upperleft portion of screen, if th e option is progra mmed.

    English Display: READY

    Some users can be given Multi-P ar tition arming a bility by being a ssigned to both

    partit ions when program ming user at tributes.When a tt empting to arm multi-part itions: You must use a Cust om English touchpad. The system ar ms only if all part itions a re ready to ar m. If an y part ition is not ready, th e system does not a rm a t a ll . You can u se the G OTO comma nd t o bypass open zones before ar ming. I f any par t i t ion is a l ready armed when g lobal a rm ing is a t tempted, tha t

    partit ion remains in its existing armed sta te.

    + [0] + arm comma nd (see list below)

    (Security Code)Multi-Partition Arming Commands

    2 = arms all partitions AWAY3 = arms all partitions STAY33 = arms all partitions NIGHT-STAY7 = arms all partitions INSTANT1 = disarms all partitions

    English Display: READY

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    32/56

    32

    Ask your installer if a"common zone" wasassigned. If so, checkthis box

    Your system ma y ha ve been set up to use a common zone, w hich isan ar ea sha red by users of both part itions, such as a foyer or lobby.If so, please note th e follow ing:

    The common zone will sound and report alarms only when bothpartit ions a re armed. If only one partition is armed, the syst emignores fault s on th e common zone.

    Either pa rtition may ar m its syst em if the common zone is

    faulted, but once armed, the other pa rtition will not be able toarm unless the common zone is first bypassed or the fa ult iscorrected.

    Fa ults on th e common zone are display ed on common zonetouchpads, a nd w ill also appear on another part itions touchpadwhen tha t par t i t ion is a rmed.

    Eith er partition can clear a nd restore the common zone after a na la rm.

    En try /exit time for the common zone is the sa me a s for part ition 1.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    33/56

    33

    The sys tem provides up to 16 end-user schedules (program ma ble by m a ster/inst alleronly), wh ich can be used t o control var ious types of events. Ea ch schedule causes a defined event t o start an d stop (when a ppropriat e) at a

    specified t ime. Schedules can be set to automa tically repeat a t va rious intervals. Schedules can be set for ra ndom sta rting, if desired.

    1. + [#] + [6] [4]

    (Mast er Code)

    2. En ter a 2-digit schedule number from 01-16.P ress [ ] to continue.

    =

    3. Enter the desired 2-digit event number from thefollowing list .00 = clear the scheduled event01 = turn a program med output on or off

    (see U s i n g D ev i c e C om m a n d s section for a list of output device numbers usedin your system)

    02 = set a user a ccess schedule for one or more users

    (see Sec u r i t y Cod e s section for a n explana tion of access groups)03 = send a latch-key report to a pager if the sys tem is not disa rmed by a specifiedtime; message sent is 777-7777.

    04 = aut omatically a rm t he system in STAY mode at a specified time (pager reportalso sent)

    05 = a utoma tica lly ar m th e system in AWAY mode at a specified time (pager reportalso sent)

    06 = aut omatically disarm the system a t a specified time (pager report a lso sent)07 = Display the word REMIN DE R at a specified time

    P ress [ ] to continue.

    4. For event number 01, enter the output numberassociat ed with this schedule.

    Otherwise, this prompt is skipped.Press [ ] to continue to the St ar t prompt below .

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    34/56

    34

    5. For event number 02, enter the access group

    number. Otherwise, this prompt is skipped.Press [ ] to continue to the St ar t prompt below .

    6. For event nu mbers 03-07, enter the part itionnumber to be armed or disarmed.0 = a rm a ll; 1 = pa rtition 1; 2 = part ition 2;3 = ar m commonOtherwise, this prompt is skipped.Press [ ] to continue to the S ta rt prompt.

    7. Enter the events s ta r t t ime and days of week.Hour = 00-23; min ute = 00-59AM = 0; PM = 1Da ys = P osition the cursor under the desired daysusing the [ ] key to move forwa rd, t hen press 1 toselect t he da y.Press [ ] to continue.

    8. Ent er the events stop time, AM/P M a nd da ys of week.Refer to step 7 for available entries.Press [ ] to continue.

    9. Ent er the desired repeat option.0 = no repeat1 = repeat schedule weekly

    2 = r epeat schedule biweekly (every other w eek)3 = repeat schedule every t hird w eek4 = repeat schedule every fourt h week

    e.g., To make a schedule tha t ha ppens everyda y youwould select all days with a repeat count of 1. To makea schedule that runs for one week then stops, selecteveryda y w ith a repeat count of 0.

    10. Select t he ra ndomize option, if desired.0 = n o; 1 = yesIf selected, the schedule times w ill vary w ithin 60minut es of the hour t ime. For example, if aschedule is set to sta rt a t 6:15pm, it w ill do so thefirst t ime 6:15pm a rrives, but on subsequent da ys itwill sta rt an ytime betw een 6:00 and 6:59 p.m.P ress [ ] to continue.

    = =

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    35/56

    35

    The system records va rious events in a history log, wh ich can be viewed by the ma steruser using a Cust om English Display touchpad. The E vent Log holds up to 100 events. Event s a re displayed in chronological order, from most recent t o oldest. When th e log is full, the oldest event is replaced by th e logging of an y new event.

    1. + [#] + 6 + 0 (Mast er Code)

    2. The system displays t he most recent event as follows: event number ty pe of event, ident ified by its corresponding code

    (see your insta ller for t he mea ning of each code) zone or user num ber (depending on t ype of event) partition in which event occurred time a nd da te of the events occurren ce.

    3. P r es sin g [ ] display s previous events (back in t ime).P ressing [#] display s events forwa rd in time.

    4 . Exit the event log by press ing any key other than [ ]or [#].

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    36/56

    36

    The TEST key puts your system into the Test mode, which allows each protectionpoint to be checked for proper operat ion.

    The touchpad sounds a single beep every 40 seconds as a reminder that thesyst em is in th e Test mode.

    Alarm messages a re not sent t o your C ustomer Ca re Center w hile Test mode is on.

    1 Disa rm the system and close all protected windows,doors, etc. The RE ADY in dicat or light should comeon if all zones are intact (i.e., all protected windows,doors, etc. are closed.

    2. + 5 th en [0] (wa lk)(Security Code) TESTTh e Di al test (opti on 1) is in tend ed f or th e in stal ler and should not be used u nl ess di r ected t o do so by your C ustom er C ar e Represent ati ve.

    = =

    3. Listen. The externa l sounder should sound for 1second and then turn off. If the sounder does notsound, CALL FOR SE RVICE .

    4. Fa ult zones. Open each protected door a nd w indow in turn an d listen for thr eebeeps from t he touchpa d. Id entificat ion (zone number or zone description) of eachfaulted protection point should appear on the display. The display clears when thedoor or w indow is closed.

    5. Walk in front of any interior motion detectors (if used) an d listen for th ree beeps.The identification of the detector should appear on the display when it is activated.The display clears w hen no motion is detected.

    N ote th at i f w ir eless moti on detectors ar e used, t here is a 3-m in ut e delay betw een activat ions. Th is i s to conser ve battery l if e.

    6. Test all smoke detectors, follow ing the ma nufa cturer's inst ructions. Theidentification of each detector should appear on t he display w hen each is a ctivated.If a problem is experienced wit h a ny protection point (no confirming sounds , nodisplay ), call for service immedia tely.When a ll protection points ha ve been checked and a re inta ct (closed), there should

    be no zone identification numbers displayed on the touchpad.7. Ex it t e s t mode: + [ 1 ]

    (Security Code)

    If the test m ode is inadvertently left active, it aut omatically turns off after 4 hours.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    37/56

    37

    "Check" and"Battery" Displays

    * Not a l l systemsuse wirelesssensors.

    The word CHECK on the touchpad's display, accompanied by a"beeping" at the touchpad, indicates a trouble condition in thesystem.

    To silence the beeping for these conditions, press any key.

    1. A display of "CHECK" and one or more zone numbersindicat es tha t a problem exists with the displayed zone(s) an drequires your attention. Determine if the zone(s) displayed areinta ct and m ake them so if they are not. If the problem ha s beencorrected, the displa y can be cleared if you enter th e OFFsequence (security code plus OFF key) tw ice. If t he displaypersists, CALL FOR SE RVICE .Note: A display of CHECK 70 on English Display touchpad sindicat es tha t t he wiring connection to the external sounder isat fault (opened or shorted), and you should CALL FORSE RVICE. S ee B EL L FAILU RE on next page. A display ofCHECK 90 indicat es tha t RF interference may be impeding theopera tion of wireless sensors* in th e system. S ee Rcvr J am on next page.

    2. If there are wireless sensors* in your system, the CHECK condition may also be caused by some change in theenvironment tha t prevents th e wireless receiver from hearing apart icular sensor. CALL FOR SERVICE if this occurs.

    IF YOU CANNOT CORRECT A "CHECK" DISPLAY,CALL FOR SERVICE .

    TYPICAL "CHECK" DISPLAYS

    06CHECK

    AC

    ENGLI SH DISPLAY TOUCHPAD

    CUSTOM ENGLI SH DISPLAY TOUCHPAD

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    38/56

    38

    Words or letters in pa rent heses ( ) a re th ose th a t ar edisplayed on En glish Display touchpad s.

    Other TroubleDisplays

    * Any beeping tha taccompa nies a tr oubledisplay can be stoppedby depressing any keyon the touchpad or by

    enter ing an OFFsequence (code + OFF)

    ** Not all systems use wireless sensors.

    COMM. FAILURE Indicates tha t a failure has occurred in(or FC ) the t elephone communica t ion por t ion of

    your system.CALL FOR SERVICE .

    SYSTEM LO BAT Indica tes tha t a low system bat tery(or BAT w ith no condit ion exist s . D ispla y iszone No.) a ccompa nied by " beeping" * a t t he

    touchpad. If this condition persists formore than one day (with AC present),CALL FOR SERVICE .

    LO BAT Indica tes tha t th ere is a low bat t ery+ z on e d es cr ipt or con dit ion in t he w ir eles s t ra n sm it ter **(or BAT w ith number displa yed (00 is RF keypa d).zone No.) Accompa nied by a single " beep" * (once

    every 40 seconds) at the t ouchpa d.Eith er replace the ba ttery yourself, orCALL FOR SERVICE. I f the ba t tery isnot replaced within 30 days, a CHECK display ma y occur.

    Rcvr J am Wireless part of the syst em is experiencing(or CHECK 90 ) RF in terference w hich ma y impede

    reception from w ireless sensors.**

    MODEM COMM(or CC )

    Indicates t ha t t he control is on-line withthe Cust omer Ca re Center 's remotecomputer.The control will not operate while on-line.Wait a few minut es the display shoulddisappear.

    BELL FAILURE Indicates th at the wiring connection to

    (or CHECK 70 ) the ext erna l sounder is a t fa ult (open orshorted). Accompanied by beeping a tthe touchpad. CALL FOR SER VICE.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    39/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    40/56

    40

    Taking Care of

    Your SystemThe components of your security sy stem a re designed to be a sma intenance-free as possible. However, to ma ke sure tha t y our systemis in relia ble working condit ion, do the following:1. Test your sys tem weekly .

    2. Test your sys tem af ter any a la rm occurs .

    Silencing LowBattery Warning

    Tones at theTouchpad

    You can silence the touchpads warning tones by pressing the OFF key ,but the touchpad's low ba ttery messa ge display w ill remain on as areminder that you have a low battery condition in one or more of yourwireless sensors. When you replace the w eak ba ttery with a fresh one,the sensor sends a " good bat tery" signal to the control as soon a s thesensor is a ctiva ted (opening/closing of d oor, w indow, etc.), cau sing thelow batt ery display to turn off. If the sensor is not a ctivated, the displaywill aut omatically clear wit hin a pproximately 1 hour.

    ReplacingBatteries in

    Wireless Sensors

    Wireless sensorsmay not havebeen used in yoursecurity system

    IMPORTANT:Use only batteriesrecommended byyour installer asreplacement.

    Ea ch wireless sensor in your syst em ha s a 9-volt or 3-volt bat tery. Thesystem detects a low bat tery in w ireless sensors, including smokedetectors, the persona l emergency tra nsmitt er, and the portablewireless touchpad an d displays a low bat tery message*. (A low bat teryin a portable wireless touchpad is detected as soon as one of its keys ispressed, an d displayed as 00 .). Battery-operated smoke detectors witha low bat tery a lso emit a single "chirp" sound approximately onceevery 2030 second s.Alkaline batteries provide a minimum of 1 year of operation, and inmost un its a nd a pplica tions, provide 24 years of service. 3-volt lithiumbat teries provide up to 4 or more year s of operat ion. Actua l bat tery lifewill depend on the environment in which the sensor is used, thenumber of signals tha t the tra nsmitt er in the sensor has ha d to send,and the specific type of sensor. Factors such as humidity, high or low temperatures or large sw ings in tempera ture, may a ll lead to thereduction of actua l batt ery life in an inst alla tion.

    * The low ba ttery message comes on a s a wa rning tha t ba ttery replacementin indicated sensor(s) is due within 30 day s. In the mea ntime, a sensorcausing a low ba ttery in dication is still fully operationa l.

    Routine Care Treat the component s of your security system a s you would any otherelectrica l equipment. D o not sla m sensor-protected doors or win dows.

    Keep dust from accumulating on th e touchpad an d a ll protectivesensors, particularly on motion sensors and smoke detectors. The touchpad a nd sensors should be cleaned car efully with a dry soft

    cloth. Do not spray water or any other fluid on the units.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    41/56

    41

    THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS

    General Your fire ala rm sy stem (if inst a lled) is on 24 hours a d a y, forcontinuous protection. In the event of an emergency, the strategicallylocated smoke and heat detectors will sound their a larm s an daut omatically send signals to your system, triggering a loud,interrupted pulsed sound* from the Touchpad(s) and any externalsounders. A FIR E m essage will a ppear at your Touchpad a nd rema inon until you silence th e ala rm (see below for silencing fire ala rms ).

    * Temporal pulse sounding is produced for Fire a lar ms, a s follows :

    3 pulsespa use3 pulsespau se3 pulsespaus e. . . , repeat ed.TYPICAL FIRE EMERGENCY DISPLAYS

    ALARM FIRE

    AC

    CUSTOM DI SPL AY TOUCHPAD E NGL ISH DI SPL AY TOUCHPAD

    SilencingFire Alarms and

    Clearing Memory

    of Alarm

    1. You can s i lence the a la rm a t a ny t ime by press ing the OFF key (thesecurity code is not needed to silence fire ala rms). To clear th edisplay, enter your code and press the OFF key aga in (to clearMemory of Alarm ).

    2 . I f the Touchpad 's FIRE display does not clear a f ter the second OFFsequence, smoke detectors ma y st ill be responding t o smoke or heatproducing objects in their vicinity. Investigate, and should this beth e ca se, elimina te th e source of heat or smoke.

    3 . I f th is does not remedy the problem, there may s t i ll be smoke in thedetector. Clear it by fanning the detector for about 30 seconds.When t he problem ha s been corrected, clear t he display byentering your code and pressing the OFF key.

    Smoke DetectorReset

    Depending on the type of smoke detectors in your system, it may benecessary to "r eset" th e smoke detectors a fter a fire ala rm ha s been

    turned off. Check with your insta ller. This " reset" is accomplished a t atouchpad, as follows:

    Ent er User C ode*, then press the [ 1] key (* except arm only user).

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    42/56

    42

    THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS

    ManuallyInitiating

    a Fire Alarm

    1. Should you become aw are of a fire emergency before your smoke orheat detectors sense the problem, go to your nearest t ouchpad an dman ually initiat e an a larm by pressing the pan ic key assigned forFIRE emergency for 2 seconds. If a key pair has been assigned forfire, press both keys at the sa me time. Check on th e next pa ge and inthe Pan ic Keys section on page 34 for furt her deta ils.

    2. Evacua te a l l occupan ts f rom the p remises.

    3. If flames and/or smoke ar e present, leave the premises and notifyyour local Fire Depart ment immedia tely.

    4. I f no f lames or smoke a re appa ren t , inves t iga te the cause of thea lar m. The zone number(s) of the zone(s) in a n a lar m condition willbe displayed a t t he touchpad.

    Using the PanicKey(s) Assigned

    for FIREEmergency

    A key or key pair may ha ve been assigned for ma nua lly initiating aFIRE a larm. See the Pan i c K eys section on page 34 for keyassignments.For convenience, indicate t he key or key pair a ssigned for fire below. I ndividual Keys

    A B C

    Press the individua l key assigned for fire for 2

    seconds.ORKey Pair s

    1 O F F a n d R E A D Y

    R E A D Y a nd #

    3 S TAY a n d #

    DISPLAYS FOLL OWING MANUAL I NITIATION OF A FIRE ALARM

    ALARMFIRE

    AC

    CUSTOM DISPLAY TOUCHPAD ENGLI SH DISPLAY TOUCHPAD

    Press t he key pair assignedfor fire at the same t ime.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    43/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    44/56

    44

    THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS

    FRONT

    BACK

    B A T H

    B E D R

    O O M

    K I T C H

    E N

    BACK DOOR

    1 FLOORST

    B E D R

    O O M

    2 FLOORND

    B A T H

    B E D R

    O O M

    P O R C H

    C L O S

    E T

    B E D R

    O O M

    B E D R

    O O M

    Est ablish a nd regularly practice a plan of escape in theevent of fire. The follow ing st eps ar e recommen ded bythe National Fire Protection Association:1. P osition your detector or your interior and/or

    exterior sounders so tha t t hey can be heard by alloccupants.

    2 . Determine two means of escape from each room.One path of escape should lead to the door thatpermits norm a l exit from t he building. The othermay be a window, should your pat h be unpassable.Sta tion an escape ladder at such windows if thereis a long drop to the ground.

    3 . Sketch a f loor p lan of the build ing . Show w indows,doors, sta irs an d rooftops tha t can be used toescape. Indicat e esca pe routes for ea ch room. K eepthese routes free from obstruction a nd post copiesof the escape routes in every room.

    4 . Assure tha t a l l bedroom doors are shut while youar e asleep. This w ill prevent dea dly smoke fromentering while you escape.

    5 . Try the door. I f the door is hot , check youralt erna te escape route. If t he door is cool, open itcautiously. Be prepared to slam the door if smokeor heat rushes in.

    6 . When smoke is present , craw l on the ground. Donot wa lk upright, since smoke rises an d ma yovercome you. Clear er air is n ear t he floor.

    7. Escape quick ly ; don 't pan ic.8. Est ablish a common meeting place outdoors, awa y

    from your house, where everyone can meet andthen ta ke steps to contact th e auth orities anda ccount for th ose missing. Ch oose someone toas sure tha t nobody returns t o the house ma nydie going back

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    45/56

    45

    FUNCTION PROCEDURE COMMENTS

    Check Zones P ress READY key. View fa ulted zones when syst em notready.

    Arm System Ent er code. Press a rming key desired:(AWAY, S TAY, N IG H T-S TAY,INSTANT)

    Arms syst em in mode selected.

    Quick Arm(if programmed)

    P ress #. Press ar ming key desired:(AWAY, STAY, INSTANT)

    Arms syst em in mode selected, q uicklyand without use of a code.

    Bypass Zone(s) Ent er code. Press B YPASS key.Enter zone number(s) to be bypassed(use 2-digit entries).

    Bypa ssed zones are unprotected an dwill not cause a n ala rm if violated.

    Quick Bypass(if programmed)

    E n t er cod e. P r es s B Y PAS S key + [ #]. B y pa s ses a ll fa u lt ed zon esautomatically.

    Silence SoundersBurglary:

    Fire:"Check":

    Ent er code. Press OFF key.

    P ress OFF key.Press any key.

    Also disarms syst em. Memory of a larmremains un til cleared.

    Memory of Alarm remains un til clear ed.Determine cause.

    Disarm System E nter code. P ress OFF key . Also s ilences sounders . Memory ofala rm remains unt il cleared.

    Clear AlarmMemory

    After disar ming, enter code aga in.Press OFF key again .

    Touchpad beeps ra pidly on entry ifala rm ha s occurred while absent. Alarmdisplay will remain upon disarminguntil cleared.

    Duress (if a ctiveand connected toCustomer Care Center)

    Arm or disarm " normally", butuse your 4-digit D uress code to do so.

    Performs desired action and sendssilent a larm to Customer Care Center.

    Panic Alarms(as programmed)

    P ress key [A], [B], or [C] for a t lea st 2seconds.

    See the Pani c Keys section foremergency functions programmed foryour system. Note: Keys A, B, a ndC ma y ha ve been program med forother functions.

    Chime Mode To tu rn ON or OFF: En ter code. PressCHIME key.

    The t ouchpad w ill sound if doors orwindows a re violated w hile system isdisarmed a nd chime mode is ON.

    Test Mode To tu rn ON: Ent er code. P ress TES T key.To tu rn OFF: Ent er code. Press OFF key.

    Tests a larm sounder a nd a llows sensorsto be tested.

    Phone Access(Smartphone Module)if applicable

    Consult Phon e Access U ser' s Gui de t h a taccompanies t he P hone Module.

    Permits system access remotely, viaTouch-tone ph one.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    46/56

    46

    SOUND CAUSE DISPLAY LOUD,INTERRUPTED *

    Touchpad & Ext .

    FIRE ALARM FIRE is displayed; zone number of zone inala rm is displayed. I f a f ire a larm is man uallyactiva ted, zone number 95 will be displayed.

    LOUD,CONTINUOUS *Touchpad & Ext .

    B URG LARY/AUD IB LEEMERG ENCY ALARM

    ALARM is display ed. Zone num ber of zone inala rm is a lso displayed.

    ONE SHORT BE EP(not repeat ed)

    Touchpad only

    a . S YSTEM D ISARMb. SYS TEM ARMI NG ATTEM P T

    WITH AN OP EN ZONE.c . BYP ASS VERIFY

    a. READY indicator light comes on.b. Number of the open protection zone display ed.

    c. Zone nu mbers of th e bypassed protection zones are displayed (one beep is hear d for each zone displayed). Subsequent ly, BYPASS is display ed.

    ONE SHORT BE EP(once every 40 secs)Touchpad only

    a. S YSTEM I S I N TES T MODEb. LO W B ATTE RY AT A TRANSMITTER

    a. Opened zone numbers will appear.b. BAT displayed w ith zone number of transmitter.

    TWO SHORT BEEPSTouchpad only

    ARM AWAY AWAY is displayed. Red ARMED indicator is lit.

    THREE SH ORTB E E P S

    Touchpad only

    a . ARM STAY, NI G H T-S TAY, ORINSTANT

    b. ZONE OPE NED WITHSYSTEM IN CHI ME MODE.

    a . STAY or INSTANT is displayed. Red ARMED indicator is lit.

    b. CHIME displayed; zone number of open protection zone will be displayed if the [ ] key is pressed.

    RAPI D BE E P I N GTouchpad only

    a . TROUB LE

    b. MEMORY OF ALARM

    c. SYSTEM LOW BATTERYd. EXT. SOU NDE R WIRING FAIL

    a . CHECK displayed. Zone number of troubled protection zone is displayed.b. FIRE or ALARM is displayed; zone number of zone in ala rm is displayed

    c. BAT displayed wit h no zone ID num ber.d. CHECK 70 is display ed.

    SLOW BE EP INGTouchpad only

    a. EXIT DELAY WARNING

    b. EN TRY D EL AY WARNI NG

    a . AWAY is display ed.

    b. Exceeding the entry delay t ime w ithout disarming causes a la rm.

    * If a bell is used as externa l sounder, fire ala rm is pul sed ri ng; burgla ry/a udible emergen cy is steady r in g .

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    47/56

    47

    SOUND CAUSE DISPLAY LOUD,INTERRUPTED*Touchpad & Ext .

    FIR E ALARM. FIRE is displayed; descriptor of zone in alar m isdisplayed. I f a f ire a larm is ma nually ac tivated, zonenumber 95 will be displayed.

    LOUD,CONTINUOUS*Touchpad & Ext .

    B UR GL ARY/AUD IB LEEMERG ENCY ALARM.

    ALARM is displayed. If progra mmed, descriptor ofzone in ala rm is also display ed

    ONE SHORT BE EP(not repeat ed)Touchpad only

    a. SYSTEM DISARM.

    b. SYSTEM ARMING ATTEMPT

    WITH AN OPEN ZONE.c . BYPASS VERIFY.

    a . DISARMED/READY TO ARM is displa yed.b. Number and descriptor of open protection zone is

    displayed.c. Numbers and descriptors of the bypa ssed zones ar e displayed (One beep is hear d for each zone displayed). S ubsequently, the following is displayed: DISARMED BYPASS /Ready to Arm.

    ONE SHORT BE EP(once every 40 secs)Touchpad only

    a. S YSTEM IS IN TES T MODE .b, L OW B ATTE RY AT A TRANSMITTER.

    a. Opened Zone identifications will a ppear .b. LO BAT displayed with description of transmitter.

    TWO SHORT BEEPSTouchpad only

    ARM AWAY. ARMED AWAY displayed. Red ARMED indicatorlit.

    THREE SH ORTB E E P STouchpad only

    a . ARM S TAY, NI G H T-S TAY,OR IN S TANT.

    b. ZONE OPENED WHILE SYSTEM IS DIS ARMED.

    a . ARMED STAY or ARMED I NSTANT displayed. Red ARMED indicator lit.

    b. CHIME displayed, descriptor of open protection zone will be displayed if the [ ] key is pres sed.

    RAPI D BE E P I N GTouchpad only

    a . TROUBLE.

    b. MEMORY OF ALARM.

    c. SYS TE M LOW BATTE RY.d. EXT. SOU NDE R WIRE FAIL.

    a . CHECK displayed. Descriptor of troubledprotection zone is d isplayed.

    b. FIRE or ALARM is displayed; descriptor of zonein a la rm is displayed.

    c. SYSTEM LO BAT displayed.d. BELL FAILURE is displayed.

    SLOW BE EP INGTouchpad only

    a. EXIT DELAY WARNING (if programm ed).

    b. ENTRY DELAY WARNING.

    a . ARMED AWAY is displayed a long w ith You May Exit Now.

    b . DISARM SYSTE M OR ALARM WIL L OCCUR is displayed. Exceeding the delay time without disarming causes an alarm.

    * If a bell is used as external sounder, fire alarm is pul sed ri ng; burgla ry/a udible emergen cy is steady r i n g .

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    48/56

    48

    RADIO FREQUENCY EMISSIONSFederal Communications Commission (FCC) Part 15This device complies wit h pa rt 15 of the FC C r ules. Opera tion is subject t o the following tw oconditions: (1) This device may not cau se ha rmful int erference, a nd (2) this device must a ccept a nyinterference received, including interference tha t ma y cause un desired operat ion.

    Industry CanadaThis Class B digi tal appara tus complies with Ca nadian ICES -003.Cet Appareil numrique de la classe B est conforme la norme NMB-003 du Ca na da.

    TEL EPHONE/MODEM INTERFACE

    FCC Part 68This equipment complies with P ar t 68 of the FCC rules. On the front cover of this equipment is alabel that conta ins the FCC registrat ion number and Ringer Equivalence Number (REN). You mustprovide this informat ion to the telephone company w hen requested.

    This equipment uses t he following U SOC ja ck: RJ31X

    This equipment ma y not be used on t elephone-compan y-provided coin service. Connection t o part ylines is subject to sta te ta riffs. This equipment is hearing-aid compat ible.

    Industry CanadaNOTICE: The Industry Canada Label identifies certified equipment. This certification means thatthe equipment meets telecommunications network protective, operational and safety requirementsas prescribed in the a ppropriat e Terminal Eq uipment Technical Requirements document(s). TheDepartment does not guarantee the equipment will operate to the user s satisfaction.

    B efore insta lling this equipment, users should ensure tha t it is permissible to be connected to thefacilities of the local telecommunica tions compa ny. The equipment mu st a lso be insta lled using anacceptable method of connection. The customer should be awa re tha t complian ce with t he aboveconditions ma y not prevent degra da tion of service in some situat ions.

    Repairs to certified equipment should be coordina ted by a representat ive designa ted by the supplier.Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may givethe telecommun ications compan y to request t he user to disconnect the equipment.

    U sers should ensure for their own protection tha t t he electrical gr ound connections of the powerutility, t elephone lines and intern al meta llic wa ter pipe system, if present, are connected together,This precaut ion ma y be par t icularly important in rural areas.

    Caution: Users should not a tt empt to make such connections themselves but should conta ctappropriat e electric inspection a uthority, or electrician, a s appropriat e.

    Ringer Equivalence Number Notice:The Ringer Equivalence Number (REN) assigned to each termina l device provides an indicationof the maximum n umber of terminals a llowed to be connected to a telephone interface. Thetermina tion on an inter face ma y consist of any combinat ion of devices subject only to therequirement tha t t he sum of the Ringer E quiva lence Numbers of all the devices does not exceed 5.

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    49/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    50/56

  • 8/10/2019 Safewatch PRO 3000 User Guide

    51/56

    51

    User SetupThe following cha rt w ill help keep tra ck of syst em users. C opies should bedistributed to the par tition 1 and part ition 2 programmers for their records.

    To program a user at tribute:Ent er ma ster/part .prog. code + [8] + user no. + # comma nd listed in column hea ding

    UserNo.

    UserName

    Users Part(s).(master code only)

    [#] [3] + part(s) + [#]

    SecurityCode

    enter new code

    Auth.Level

    [#] [1] + level

    AccessGroup

    [#] [2] + group

    RF ZoneNumber

    [#] [4] + zone no.

    Pageron/off

    [#] [5] + 0/1

    01 installer (all) installer (0)02 master (all) master (0)03 part. 1 prog (1) (4) (0)04 (1) (0) (0)05 (1) (0) (1)06 (1) (0) (1)07 (1) (0) (1)08 (1) (0) (1)09 (1) (0) (1)10 (1) (0) (1)11 (1) (0) (1)12 (1) (0) (1)13 (1) (0) (1)14 (1) (0) (1)15 (1) (0) (1)16 (1) (0) (1)17 (1) (0) (1)18 (1) (0) (1)19 (1) (0) (1)20 (1) (0) (1)21 (1) (0) (1)22 (1) (0) (1)23 (1) (0) (1)24 (1) (0) (1)25 (1) (0) (1)26 (1) (0) (1)27 (1) (0) (1)28 (1) (0) (1)29 (1) (0) (1)

    30 (1) (0) (1)31 (1) (0) (1)32 (1) (0) (1)

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    52/56

    52

    User Setup (continued)

    (Ent er ma ster/part.prog. code + [8] + user no. + # comma nd listed in column hea ding )UserNo.

    UserName

    Users Part(s).(master code only)

    [#] [3] + part(s) + [#]

    SecurityCode

    enter new code

    Auth.Level

    [#] [1] + level

    AccessGroup

    [#] [2] + group

    RF ZoneNumber

    [#] [4] + zone no.

    Pageron/off

    [#] [5] + 0/1

    33 part. 2 prog (2) (4) (1)34 (2) (0) (1)35 (2) (0) (1)36 (2) (0) (1)37 (2) (0) (1)38 (2) (0) (1)

    39 (2) (0) (1)40 (2) (0) (1)41 (2) (0) (1)42 (2) (0) (1)43 (2) (0) (1)44 (2) (0) (1)45 (2) (0) (1)46 (2) (0) (1)47 (2) (0) (1)48 (2) (0) (1)49 (2) (0) (1)

    Authority Levels: 0 = standard user Partitions: 0 = clears partition 1 and partition 2 assignments

    1 = arm only 1 = partition 12 = guest 2 = partition 23 = duress 3 = common partition4 = partition programmer Paging: 0 = no paging

    1 = allow paging

    Paging SetupAutomatically Reports Upon Sched. Func. Key

    open/close alarm/trouble zone listPager

    Pager Phone Number\ Prefix Characters p1 p2 p1 p2 p1 p2

    1

    2

    3

    4

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    53/56

    53

    Schedules (ma ster code + [#] + [6] [4])No. Event Device No. Group No. Partition Start Stop Repeat Random

    (see list below) for 01 events: for 02 events: for 04-06 events: Time/ Time/ (yes/no) (yes/no)enter 01-18 enter 1-8 enter 1, 2, or 3 Day Day

    0001020304050607

    080910111213141516Events: 01 = device on/off 04 = forced STAY arm 07 = display reminder

    02 = user access 05 = forced AWAY arm03 = latch key report 06 = auto disarm

    List of Output DevicesDevice Description Schedule No. Function Key

    010203040506070809101112131415161718

    oaded from www.Manualslib.com manuals search engine

    http://www.manualslib.com/http://www.manualslib.com/
  • 8/10/2019 Safewatch PRO 3000 User Guide

    54/56

    54

    WARNING! THE LIMITATIONS OF THIS ALARM SYSTEMWhile this system is an a dvanced design security system, it does not offer gua ran teed protection against burglary or otheremergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for avariety of reasons. For example: Intruders may gain access through unprotected openings or have the technical sophis t icat ion to bypass an alarm

    sensor or disconnect a n ala rm w arn ing device. Intrus ion detectors (e .g. pass ive infrared detectors ), smoke detectors , and ma ny other sens ing devices wil l not work

    without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries arenot put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason,however briefly.

    S ignals sent by wireless t ransmit ters may be blocked or ref lected by metal before they reach the alarm receiver. Evenif the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved intothe path .

    A user may not be able to reach a panic or emergency button quickly enough.