S c a n R e f Scandinavian Refrigeration Energy Food...Process refrigeration Industriel...

44
Process refrigeration Industriel refrigeration THEME: S c a n R e f Scandinavian Refrigeration Energy Food No. 1 . February 2009 Keeping Cool the Natural Way Danske Køledage 2009 i Odense

Transcript of S c a n R e f Scandinavian Refrigeration Energy Food...Process refrigeration Industriel...

  • Process refrigerationIndustriel refrigeration

    T H E M E :

    S c a n R

    e f

    Scandinavian Refrigeration ! Energy ! Food

    No. 1 . February2009

    Keeping Cool the Natural WayDanske Køledage 2009 i Odense

  • ScanRef38. volume – no. 1 February 2009ISSN-nr.: 0284-0758 ScanRef is published on behalf of the Associa tions of Refrigeration in Denmark, Norway, Sweden, Finland and Iceland.

    Publisher:ScanPub ApSVejlbovej 31, DK-8600 SilkeborgTel.: +45 8680 0299Fax: +45 8680 5839E-mail: [email protected]

    Editorial Offi ce:Jens Utoft, chiefeditorÅstien 3, DK-7800 SkiveTel.: +45 9751 4595E-mail: [email protected] Sweden:Anders HiorthBanvallen 11, S-429 30 KullavikTel.: +46 708 45 12 00Fax: +46 31 933 565E-mail: [email protected] Norway:Svein Erik PedersenBuerstadvn. 19, N-3135 TorødTel.: +47 3303 1000Fax: +47 3303 1104E-mail: [email protected] Advertising:Denmark og Norway:Lars GøhnsMariagervej 48, 2.DK-8900 RandersTel.: +45 2068 7740Fax: +45 8680 5839E-mail: [email protected], Finland and International:Anders HiorthBanvallen 11, S-429 30 KullavikTel.: +46 708 45 12 00Fax: +46 31 933 565E-mail: [email protected]

    Subscription:ScanPub ApSVejlbovej 31, DK-8600 SilkeborgTel.: +45 8680 0299Fax: +45 8680 5839E-mail: [email protected]:Scandinavian ................. 450 DKKEurope ........................... 675 DKK

    Graphic Design:Per Jensen, PJ Grafi skVejlbovej 31, DK-8600 SilkeborgTel.: +45 8680 0299Fax: +45 8680 5839E-mail: [email protected]

    Print:Johnsen Offset, Grenaa

    Frontpage Photo:Gea-Grenco Køleteknik A/S

    Edition closed at 8. February 2009

    Co

    nte

    nts

    g

    Energimærkning af varmepumper ................................ Side 9Energistyrelsen i Danmark oprettet en foreløbig oversigt over energimærkede varmepumper.

    Isvandskølecentral med frikøling .................................... Side 10GEA Grenco Køleteknik A/S har installeret en 2,0 MW isvandskølecentral på ingrediensfi rmaet Chr. Hansens nye fabrik i København.

    Køledage med fokus på energi og miljø ......................... Side 13Faglige foredrag med tre hovedspor på Danske Køledage i Odense 12.-13. marts

    Energibesparing som exportvara ................................... Sida 16ClimaChecks metod för energie! ektivisering har nått internationella framgångar.

    Svensk Kylteknik på export ............................................ Sida 25Miljövänlig, svensk kylteknik från Frigadon och AIA bär frukt i England.

    Stor fremtid for CO2-løsninger ...................................... Side 28Danfoss-seminar i Oslo 28. januar samlede 105 deltakere fra hele Norge. Snart 500 anlegg i drift i Norden.

    Standard ammonia chiller as a heat pump .................... Page 32The behaviour of heating systems at o! –design conditions and the infl uence on ammonia heat pump design performance.

    Refrigeration with a Hydrocarbon for a Brewery .......... Page 38By using R 290 propane and ethanol the refrigeration plant at Svaneke Bryghus is ultimately „green” and competitable with HFC-solutions.

  • tt coil aswww.tt-coil.dk

    Tlf: +45 98 15 95 00Fax: +45 98 15 90 85

    Asarums Industri ABwww.aia.se

    Tlf: +46 454 334 00Fax: +46 454 32 02 95

    www.kylma.se

    Correct temperature for people, machines and products

  • 4 [ScanRef . 1 . February 2009]

    NE

    WS

    Kølebranchen lever i en brydningstid, der ikke er set mage.

    Producenter, virksomheder og kølefi rmaer må hele tiden agere for at leve op til de sta-dig stigende krav på et områ-de, som i forvejen er stærkt reguleret. Fokus på sikkerhed, energi og miljø har aldrig væ-ret større i den danske køle-branche. Aldrig har kølebran-chen oplevet så mange regler, reguleringer og krav – natio-nalt såvel som internationalt – som nu.

    „Desværre oplever vi en manglende koordinering fra myndighedernes side af de mange regelsæt”, fastslår Lau Vørs, formand for Dansk Kø-ledag forud for kølebranchens årlige konference og udstil-ling, Danske Køledage i Odense 12.-13. marts.

    Kølebranchen er i dag un-derlagt regler, der er udstedt af Beskæftigelsesministeriet (Arbejdstilsynet), Miljømini-steriet (Miljøstyrelsen), Kli-ma- og Energiministeriet (Energistyrelsen) og Forsvars-ministeriet (Beredskabsstyrel-

    sen) for at nævne de største ministerielle aktører. Dertil kommer de internationale re-guleringer i EU-regi.

    „Som branche er det for-virrende og frustrerende at skulle leve op til en masse reg-ler, som burde være samlet og koordineret ét sted – af én myndighed. Med andre ord: Et land – og et sæt regler, der respekteres af alle ministerier. Samtidig bliver virksomhe-derne mødt med nye krav om bl.a. efteruddannelsen af medarbejdere”, siger Lau Vørs.

    I forvejen er den danske kø-lebranche – i kraft af den stærke regulering inden for brug af de drivhus-skadelige og ozonlagsnedbrydende kø-lemidler – førende i forhold anvendelsen af de naturlige kølemidler. Alligevel ser bran-chen med en vis skepsis på de fremtidige reguleringer i en tid med nye politiske tiltag på miljøområdet.

    Det gælder både nationalt og internationalt.

    „Vi har imidlertid brug for at få ro og klarhed, så produ-center, virksomheder og køle-fi rmaer i større omfang kan planlægge udviklingen af virksomheden og medarbej-derne. I andre lande eksiste-rer ikke samme uklarheder myndighederne imellem. Der er det overblik, vi savner i Danmark: Et regelsæt – et mi-nisterium”, mener Lau Vørs.

    Kølebranchen i en brydningstid

    Lau Vørs, formand for Dansk Køledag

    With the objective to expand growth in the market segment for complete cooling solu-tions, Embraco has launched the Armonia, a condensing unit for external environments.

    The product stands out for its high quality, low noise, robust and modern design, which en-sures easy installation and maintenance.

    The Armonia was lauched at AHR Expo, the largest refriger-ation trade fair in the United

    States, held from January 26 to 28, 2009, in Chicago, Illinois.

    According to the Corporate Commercial Sales manager John Lange, the Armonia is ideal for light commercial ap-plications, in environments with space and noise restrictions. The key advantage of this prod-uct is that it can be located sep-arately from the cabinet, and installed in an external area.

    To facilitate maintenance, a frontal door was installed, giv-ing access to the entire system. Produced at Embraco's plant in Slovakia, the condensing unit

    uses NT and NJ compressors that are compatible with many refrigerant blends and R404a.

    Embraco participated in the AHR with a 74.3 m2 stand, which also highlighted new commercial EM models and the complete line of compres-sors for commercial refrigera-tion. This includes compressors developed for use with CO2 and propane. „At Embraco, sustainability is a business stra-te gy. We look to o! er solutions that are more energy e" cient and at the same time compati-ble with more environmentally

    friendly refrigerants”, states the manager.

    As the recognized world lead-er in the compressor market for refrigeration, Embraco enjoys close to 50% of the North American market. This was ac-complished in part due to the lead role we maintain with re-spect to high e" ciency prod-ucts. „We are able to supply the products required to meet the new restrictive regulations for energy consumption that go in-to e! ect in the United Sates in 2010”, assures the executive.

    New external condensing unit

    Today there are still confusion and uncertain-ties in the refrigeration and air-conditioning industry related to work-ing fl uids in many applica-tions, mostly due to ozone depletion and global warming and the regula-tions governing these issues.

    „Ammonia refrigerant is one of the best options to resolve these problems”, says Dr. Risto Ciconkov, Professor at Faculty of Mechanical Engineering, University „Sv. Kiril and Meto-dij” in Skopje. Macedonia

    Risto Ciconkov is President of the Organising Committee for the international conference on Ammonia Refrigeration Technology to be held in Ohrid, Republic of Macedonia May 7-9 this year.

    The conference is organized in cooperation with Interna-tional Institute of Refrigera-tion, IIR.

    The conference is a joint con-ference of Commission B2 (Re-frigerating equipment) with Commission B1 (Thermody-namics and transfer processes) and Commission D1 (Refriger-ated storage).

    Programme sponsors are eurammon and International Institute of Ammonia Refriger-ation, IIAR.

    Since the last decade there are many technological innova-tion and improvement of am-monia equipment and systems

    presented at the conferences in Ohrid: - New types of steel plate heat

    exchangers, shell-and-tube types with enhanced steel tubes and introduction of microchannel aluminium ex-changers.

    - Ammonia semi-hermetic compressors are on the mar-ket and hermetic scroll com-pressors are under testing.

    - New oils miscible with am-monia enabling use of DX evaporators.

    - New concept for compact constructions of refrigerating units, fully sealed and tested in factories. Ammonia water chillers for air conditioning systems with less than 50 kg ammonia charge.

    - New secondary coolants with better heat transfer: CO2, po-tassium-acetate, alkali (am-monia-water solution).

    - Cascade NH3/CO2 refriger-ating systems as the best solu-tion for low temperatures. Compact design.

    - New refrigerant R723 (blend of Ammonia and Dimethyl-Ether) suitable for small and medium refrigerating sys-tems.

    - Absorption technology in tri-generation, heat pumps, el. power generation systems etc.

    Among the keynote speakers are Anders Lindborg, Ammo-nia Partnership, Gert Koster, Grasso and Andy Pearson, Star Refrigeration.

    New ammonia conference

  • [ScanRef . 1 . February 2009] 5

    NE

    WS

    Together with Zamil Indu-strial, the Saudi Arabian manufacturer of construc-tion materials, Armacell has now opened its new location in the Gulf region.

    In May 2008, Armacell and Zamil Industrial signed a joint

    venture agreement to produce fl exible technical insulation ma-terials in Saudi Arabia.

    The Armacell Zamil Middle East Company is situated in Dammam, a port city on Saudi Arabia’s east coast.

    The medium-term plan is to supply the en tire Middle East

    Armacell expands into the Gulf region

    Insulation materials made by Armacell have been used in numerous construction projects in the Gulf region, for example in the famous Burj al Arab, Dubai’s landmark building.

    region with Armafl ex and other technical insulation materials from here.

    The Armacell Zamil Middle East Company Ltd., of which Armacell holds 51%, is the in-sulation manufacturer’s fi rst joint venture.

    Whereas other new geo-graphical markets have been opened up by the company’s own subsidiaries, in the Arabi-an region Armacell has deliber-ately opted for cooperation with a business partner who is well-known and well-estab-lished in this area.

    Many oil states are preparing for the time after the oil re-serves have dried up.

    Therefore, the Gulf region is currently experiencing an un-precedented building boom and there is no sign of it end-ing.

    In the United Arab Emirates the construction sector is al-

    ready the second most impor-tant industry after oil.

    Along with the building boom, the de mand for modern solutions in refrigeration and air-conditioning technology has also grown.

    Insulation materials made by Armacell have already been used in many con struction projects in the Gulf region.

    In the famous Burj al Arab, the world’s only 7-star hotel and Dubai’s landmark, several thousand metres of Armafl ex tubes were used.

    And the recently opened At-lantis, The Palm Hotel on the artifi cial palm island o! the coast of Dubai has also placed its trust in Armacell products for the insulation of the refrig-eration technology.

    Kylbranschens Samarbetsstiftelse KYS har per 09-01-01 ändrat såväl inriktning som struktur.

    Allt sedan KYS bildades 1988 har den huvudsakliga inrikt-ningen varit att för kylbranschen vara ett samarbetsorgan mot myndigheter och institutioner, och som främsta uppgift har varit framtagandet och under-hållandet av Svensk Kylnorm.

    I samband med att det svens-ka antagandet av den europeis-ka kylnormen EN 378 har för-utsättningarna väsentligen för-ändrats och därmed har KYS fått denna förändring.

    Förändring för svensk KylnormDetta innebär bl. a att fr.o.m. 2009-01-01 har KYS upphört med all verksamhet knuten till Svensk Kylnorm. Denna verk-samhet har från samma tid-punkt övertagits av Kyl & Vär-mepumpföretagen som därmed blir ny huvudman för kylnor-men.

    Den gula delen som heter Energie! ektiva Kyl- och Vär-mepumpanläggningar – Rikt-

    linjer, har dock även Svenska Kyltekniska Föreningen rättig-heten till att fullt ut uppdatera, utveckla och marknadsföra.

    AnslagsverksamhetenKYS syfte är som tidigare att verka för hög kvalité på värme-pumpar och kylanläggningar i fråga om säkerhet, arbetsmiljö, yttre miljö och för en hög kom-petens hos de företag och per-soner som på något sätt blir berörda av sådana anläggning-ar.

    För detta ändamål stödjer stiftelsen genom anslag, delfi -nansiering av kvalifi cerade forsknings- och utvecklingspro-jekt, samt utbildningsinsatser av samma karaktär.

    Stiftare är som tidigare Svens-ka Kyltekniska Föreningen (KTF), Svenska Kylimportörers Förening (SKIF) och Kyl & Värmepumpsföretagen (KVF) och stiftelsen äger som tidigare majoriteten i ett speciellt ackre-diterat certifi eringsbolag IN-CERT, som utför bl. a person-certifi ering.

    Ansökningar om anslag sker enligt en 8-punkters projekt-plan och detta kommer att de-taljpreciseras inom kort.

    KYS i ny skepnadFrom the outside horizontal and vertical freezers from DSI (Dybvad Stål Industri) look very much the same.

    „But most of our products are never the less tailored to the di! erent needs of our customers”, DSI explains in the company’s December-newsletter.

    Onshore and o! shore freezing under very di! erent circumstances calls for di! er-ent solutions, and the adjust-ments add new ideas to the ongoing development of even better freezers.

    „For that we are grateful and we believe all our cus-tomers benefi t from it”, ex-plains Regional Export Man-ager Mads Sigsgaard from DSI.

    As an example he men-tions the delivery of six verti-cal freezers to the Dutch meat company Ferdinand Zandbergen in Woudenberg, The Netherlands during Springtime 2008.

    „A specifi c problem con-

    cerning unloading a specifi c type of product surprisingly gave us some headache, but Zandbergen itself suggested a path towards a solution and we started working on it. Now the six freezers are do-ing the job perfectly and Zandbergen calls it a „fantas-tic solution”, says Mads Sigs-gaard.

    The freezer in question is the V 30 36/100. In Wouden-berg it has an automatic un-loading by the means of an overhead crane. The freezer is based on the classical Gram freezer technology for which DSI holds the rights and pat-ents.

    The DSI V20 vertical freezer with a Bjørdal auto-matic top unloading system is popular in Norway. The stern trawler „Granit IV” of Aalesund is to have six V20 installed on board following the delivery of the fi rst eight of their kind to another Nor-wegian trawler „M/S Andøy-buen”.

    The unloading system is made by the Norwegian com-pany Bjørdal Industries.

    Customized freezers from DSI

  • 6 [ScanRef . 1 . February 2009]

    NE

    WS

    Asarums Industrier AB, som ingår i Beijer Ref, har nu tagit steget och utrustar många av sina fl äktluftky-lare, kondensorer och kylmedelkylare med EC-motorer och fl äktar från ebm-papst.

    „Att bygga stora asynkronmo-torer med mycket hög e! ektfak-tor är ingen konst” säger Tord Engberg och Mats Birgersson på AIA, „men då pratar vi om e! ekter på fl era hundra, kanske tusen kiloWatt. De fl esta av våra motorer är på under 1 kW”.

    En typisk fl äktenhet på en fl äktkylare kan vara på 67 W tillförd e! ekt. I motorn tappar man 50 W, i fl äkten 11 W. Kvar är 6 W i ute! ekt. Samma räk-neexempel med en nya ebm-fl äkten ger följande resultat, 24 W i ine! ekt, 9,5 W i e! ektför-lust i motorn och med 8,5 W bortfall i fl äkten återstår även här 6 W.

    Förluster i första fallet: 61 WAvgiven e! ekt: 9%Förluster i andra fallet: 18 WAvgiven e! ekt: 25%

    Varje sådan här liten fl äkt spa-rar alltså 43 W och då är ingen

    Principdiagram för EC-motor

    AIA-fl äktar kör energisnålt

    hänsyn tagen till den mindre kyle! ekt som krävs eftersom 43 W/fl äkt tillförs rummet som den sitter i.

    „En fl äkt är = ingen fl äkt“ men i ett större rum med 11-12 fl äktar ökas kylbehovet med ca 0,5 kW!

    Hisnande perspektivSannolikt vet ingen hur många sådana här fl äktar som är i drift världen över, men en sak är klar, för varje sådant här utbyte som görs på en enda fl äkt som går kontinuerligt (8.760 h/år) spa-ras det 377 kWh.

    Finns det 1 miljon fl äktar sparas 377.000.000 kWh fi nns det 10 miljoner fl äkt (vilket är mera sannolikt) blir besparing-en 3.770.000.000 kWh eller smått otroliga 3.770.000 MWh årligen.

    EC-motor, vad är det?Kortfattat, det är en borstfri permanentmagnetiserad, syn-kronmotor med elektronisk strömriktare.

    Därav namnet „Electronical-ly Commutated motor = EC-motor.

    I de fl esta fall monteras den elektroniska styrningen inne i själva motorn. Detta ger för-enklad installation, mindre risk för störningar, integrerat mo-torskydd m m.

    EC-motorer ger inte bara möjlighet till steglös varvtals-styrning, man kan också klara ett större spänningsområde, så-väl vid 1-fas som vid 3-fasdrift.

    Man kan styra grupper av fl äktar, man kan styra på tryck/temperatur/drifttimmar. Man kan programmera dem via PC eller PDA och det går också bra trådlöst via Bluetooth! Och om inte detta är tillfyllest så kan man köra som vi gjorde förr, On-O! !

    „Vi investerar mycket i den här tekniken nu, vi kommer att storlansera dessa produkter på RAC-mässan i Birmingham den 24-26 februari 2009” av-slutar Mats Birgersson.

    Autoriserede Kølefi rmaers Brancheforening godkend-te på sin generalforsam-ling i november et forslag om at undersøge mulighe-den for at oprette en egentlig arbejdsgiverfor-ening som et frivilligt tilvalg for foreningens medlemmer.

    Hvis den nye arbejdsgiverfor-ening oprettes, skal den admi-nistreres af en eksisterende ar-bejdsgiverforening uden øko-nomiske omkostninger for for-

    eningen AKB. Subsidiært har bestyrelsen fået bemyndigelse til at forhandle en associerings-aftale på plads med en i forve-jen eksisterende arbejdsgiver-forening-

    „Baggrunden for beslutnin-gen er, at en virksomhed i dag skal forholde sig til mange juri-diske spørgsmål, herunder kon-trakter og ansættelsesretlige spørgsmål”, siger Lau Vørs, der er direktør i AKB.

    Nogle af disse spørgsmål vil blive løst som medlem af en ar-bejdsgiverforening, der er dæk-

    ket af en kollektiv overenskomst om løn- og ansættelsesforhold.

    Lau Vørs tilføjer at AKB’s spidskompetence ligger på or-ganisation og tekniske spørgs-mål – ikke på jura og ansættel-sesforhold.

    Foreningen kunne derfor en-ten vælge at ansætte en jurist til at løse disse opgaver eller un-dersøge muligheden for at etab-lere et samarbejde med andre organisationer, som i forvejen har de nødvendige kompeten-cer til at løse den slags opgaver.

    „Vi har et godt samarbejde med vores medlemmer, men har hidtil måttet henvise til an-dre i spørgsmål om jura og an-sættelsesforhold, siger Lau Vørs.

    Hvis arbejdsgiverforeningen bliver etableret, kan medlem-mer af AKB fortsætte på de hidtidige vilkår. Hvis de ønsker at være med i en arbejdsgiver-forening, skal det tilvælges som en ekstra ydelse.

    Nogle medlemmer er allere-de medlem af en arbejdsgiver-forening ved siden af deres medlemskab af AKB og er der-

    Arbejdsgiverforening for kølefi rmaer?

    med også dækket af overens-komster. Men rigtig mange la-ver individuelle kontrakter med deres medarbejdere og er så henvist til privat rådgivning ved eventuelle tvister.

    Ved at lave en særlig arbejds-giverforening for AKB-med-lemmer håber AKBs bestyrelse at kunne sikre medlemmerne bedre vilkår.

    Hvilken organisation, der i givet fald bliver tale om, er end-nu ikke afgjort.

    Bestyrelsen drøftede på et møde i januar, hvilke betingel-ser, der skal være opfyldt og hvilke organisationer man skul-le indlede drøftelser med om et samarbejde.

    Ifølge forslaget etableres ar-bejdsgiverforeningen med en prøveperiode på op til tre år.

    Det amerikanske senats fi nansudvalg godkendte 27. januar den del af præsident Barack Obamas økonomiske genopretningsplan, som angår støtte til alterna-tive energikilder og energibesparelser.

    Planen indebærer, at private husholdninger får 30 pro-

    cents skattefradrag for at in-stallere energibesparende ov-ne, varmtvandsbeholdere, sol energianlæg, vindmøller, varmepumper og andre ener-gibesparende apparater.

    Dertil kommer 2 mia. dol-lars til lån og tilskud til om-bygning af private boliger.

    Lovforslaget underskrives af præsident Obama 16. feb-ruar.

    USA støtter varmepumper

    Lau Vørs, direktør, AKB

  • [ScanRef . 1 . February 2009] 7E M E R S O N. C O N S I D E R I T S O L V E D™.

    The Emerson Climate Technologies logo is a trademark and service mark of Emerson Electric Co. Emerson Climate Technologies Inc. is a subsidiary of Emerson Electric Co. Copeland is a registered trademark and Copeland Scroll is a trademark of Emerson Climate Technologies Inc.

    Digital Scroll™ is a unique and innovative technology

    for capacity control in refrigeration, air-conditioning

    and heat-pump applications. Based on the Copeland

    Compliant Scroll® design, it is a simple and reliable system

    that provides the widest range of stepless modulation

    from 10% to 100% ensuring optimum system efficiency.

    It is quick and easy to design and implement into existing

    equipment, simple to commission and to operate as it does

    not require any additional system components.

    Digital Scroll™ gives you the flexibility you need in

    modulation and keeps your system architecture simple

    with the reliability you expect from Copeland Scroll™.

    Plus, as your capacit y precisely matches your load

    what ever the condit ion, you are reducing your energy

    consum pt ion.

    For more informat ion please contac t your local

    representat ive or visit www.em ersonclimate.eu

    DIGITAL SCROLL™. CONTINUOUS MODULATION MADE EASY

    Emerson Climate Technologies GmbH., Pascalstr. 65, 52076 Aachen-Oberforstbach, Germany.Phone Number: +49 2408 929 0 - Fax: +49 2408 929 570 - Web: www.emersonclimate.eu.

    WIDE CAPACITY CONTROL MAKES

    A DIFFERENCE

  • 8 [ScanRef . 1 . February 2009]

    NE

    WS

    Grundfos har udvidet produktprogrammet med en løs væghængt frekvens-omformer, Grundfos CUE, der kan regulere pumper helt op til 250 kW.

    Udviklingen af den nye fre-kvensomformer er en naturlig videreførelse af Grundfos' ind-

    Frekvensomformer til store pumper

    Næstved-virksomheden Novenco varslede den 28. januar afskedigelse af 20 procent af virksomhe-dens 400 ansatte.

    Det drejer sig om cirka 50 ti-melønnede og 35 administra-tive medarbejdere.

    Begrundelsen er en halve-ring af ordretilgangen i no-vember og december 2008 samt en dårlig januar.

    For et år siden gik virksom-heden ellers i gang med et in-vesteringsprogram for mere en 100 mio. kroner på fabrik-ken i Næsted samtidigt med opførelsen af en samlefabrik i Kina, hvor store dele af mari-ne og o! shore industrien er samlet.

    Novenco fremstiller ventila-tionsanlæg, brandsikringssy-stemer og kølesystemer, hvor-af en væsentlig del til marine

    og o! shore. Novenco har ho-vedsæde i Danmark og afde-linger i Norge, Holland og Ki-na. Desuden er der salgskon-torer i Sverige, Italien, Singa-pore og UK. Virksomheden tæller i alt 650 ansatte på ver-densplan.

    Novenco har tidligere været en del af York og Johnson Controls, men blev i 2007 solgt til den private kapital-fond, Dania Capital.

    Novenco fyrer 85 ansatte

    sats inden for E-pumpe-tekno-logi med hastighedsregulerede pumper.

    Hastighedsregulering af pumperne ved hjælp af fre-kvensomformere har været en del af Grundfos’ produktpro-gram i næsten 25 år. I dag fi n-des den integrerede løsning med Grundfos pumper til og

    med 22 kilowatt. Men når pum-pen har en e! ekt på over 22 ki-lowatt, vil frekvensomformeren fylde så meget, at det kan være mere hensigtsmæssigt med en ekstern løsning.

    „Der er stor fokus på ener-gioptimering via hastighedsre-gulering, og selvom vi gennem årene har integreret frekvens-omformere i større og større pumper, må vi nok konstatere, at pumper med integrerede fre-kvensomformere ikke kommer væsentligt højere op i størrelse. Derfor har vi udviklet vores egen frekvensomformer til de store pumper eller til applikati-oner, hvor den integrerede løs-ning ikke ønskes eller ikke er mulig, f.eks. i ATEX-miljø,” si-ger salgsingeniør Johnny Schou, Grundfos DK A/S.

    Grundfos CUE er velegnet til alle typer centrifugalpumper uden for E-pumpe-program-

    met og kan regulere pumper helt op til 250 kilowatt. CUE kan anvendes både til nye og eksisterende pumper.

    „Med CUE kan vi tilbyde vo-res kunder en 100% Grundfos løsning, hvor pumper og sty-ring passer perfekt til hinanden. Det er en klar fordel for vores kunder, at de kan vælge én leve-randør og én producent til hele løsningen, siger Johnny Schou.”

    Med Grundfos CUE regule-res forbruget i forhold til det ønskede fl ow, temperatur, tryk eller di! erenstryk. CUE tilpas-ser sig hele tiden de forhold, der er i anlægget.

    Grundfos er med på Danske Køledage, stand nr. 1.

    Danmark har fået et videncenter for energibe-sparelser i bygninger på Teknologisk Instituts grund i Høje Taastrup, hvor det nye konsortium har til huse.

    Det betyder, at håndværkere, entreprenører, rådgivere, ener-gikonsulenter, leverandører og mindre virksomheder i bygge-branchen nu kan henvende sig her for at få mere viden om praktiske muligheder for at be-grænse energiforbruget i boli-ger.

    „Vores ambition er at bidra-ge til at bringe Danmark i front

    inden for energisektoren. Ek-sempelvis skaber vi med det nye byggeri ’EnergyFlexHouse’ nye rammer for virksomheders ud-vikling og afprøvning af energi-besparende teknologi til bygge-riet”, oplyser instituttets direk-tør Søren Stjernqvist.

    Målet er at tænke nye tanker og sætte turbo på fremtidens in-tegrerede og tidsbesparende in-novationsproces lige fra design og idéudvikling, udvikling af prototyper og produktmodning til produkternes markedsind-trængen.

    Centrets opgave er stor og kompleks. 40% af Danmarks energiforbrug fi nder sted i byg-

    ninger, og der er et kæmpe po-tentiale for besparelser men og-så mange barrierer. For at løfte opgaven skal centret samarbej-de med organisationer, myn-digheder og virksomheder.

    Lederen af centret bliver Vagn Holk Larsen fra Teknolo-gisk Institut, og han ser frem til at smøge ærmerne op:

    Nyt center for energibesparelser„Vi vil kunne hjælpe med at

    ska! e oplysninger om specifi k-ke tekniske løsninger, produkt-guider, uddannelse, fi nansie-ringsmuligheder, lovgivning, økonomi og meget mere”, for-tæller han og fortsætter: „Der er et stort potentiale i at realise-re energibesparelser i bygnin-ger. Det er fantastisk ærgerligt, hvis mange gode og rentable besparelsesprojekter falder på gulvet, fordi den konkrete viden om potentialerne og de tekni-ske løsninger er spredt på man-ge aktører og derfor virker van-skelig og uoverskuelig at anven-de i den aktuelle situation – men det får vi rettet op på nu”, siger Vagn Holk Larsen.

    Det nye center, som slog dø-rene op den 5. januar 2009. Energistyrelsen har afsat 32 millioner kroner til at etablere og drive centret i perioden 2008-2011.

    Udover Teknologisk Institut består konsortiet af Statens Byggeforskningsinstitut, Aal-borg Universitet, konsulentfi r-maet Viegand & Maagøe samt KommunikationsKompagniet. Som faste underleverandører til konsortiet er Dansk Energi, Se-bra A/S og Danmarks Tekni-ske Universitet.

    Vagn Holk Larsen, leder af det

    nye videncenter.

  • [ScanRef . 1 . February 2009] 9

    NE

    WS

    Stigende energipriser har fået stadig fl ere danske forbrugere til at interes-sere sig for varmepumper.

    Derfor stiller kølegrossisten H. Jessen Jürgensen store forvent-

    ninger til sin nyeste luft/vand varmepumpe, ANLI 02OH fra fi rmaet Aermec, som præsente-res på Danske Køledage i Odense.

    Det er en chiller varmepum-pe med en kølekapacitet på

    Nyheder fra Jessen Jürgensen

    5,88 kW og en varmekapacitet på 6,18 kW, der kan reguleres fra 35% til 100%.

    I løbet af foråret lanceres fl e-re størrelser.

    ANLI 02OH leveres i tre mo-deller henholdsvis uden pum-pe, med on/of pumpe og med inverter pumpe. Den er udsty-ret med en elektronisk termo-statisk ventil, som giver en høje-re energie! ektivitet ved veks-lende belastning.

    En varmtvandstemperatur op til 55ºC er garanteret med en udetemperatur mellem -10ºC og 42ºC.

    Fra den tyske kompressorfa-brikant Bitzer præsenterer H. Jessen Jürgensen bl.a. sugegas-kølede kompressorer med fre-kvensomformere, hvor kapaci-teten kan reguleres fra 30 til 87 Hz, som sikrer en god tilpas-ning af kapaciteten til det aktu-elle behov.

    I øvrigt har H. Jessen Jürgen-sen udviklet en ny trykprøv-ningsmanifold til trykprøvning af rørsystemer i køleanlæg med mere end 2,5 kg kølemiddel-fyldning.

    Trykprøvningsmanifolden,

    der også vises på messen, er ud-styret med et 0-60 bar mano-meter, samt 2 stk. sikkerheds-ventiler for test i trykområder-ne henholdsvis 3,4 – 24 bar el-ler 24 – 51,5 bar.

    Sikkerhedsventilerne er ud-styret med quick-ko blinger, der gør det nemt og hurtigt at skifte fra det ene trykområde til det andet.

    Manifolden, med slanger, le-veres i en praktisk alu-miniumsku! ert, og har en sam-let vægt på 5 kg.

    H. Jessen Jürgensen slog i ja-nuar dørene op til en ny butik og lagerhal i fi rmaets afdeling i Ballerup, som er udvidet med 1.000 m2.

    Firmaet, der er en del af Beijer Ref-gruppen. har des-uden afdelinger i Kolding og Århus.

    H. Jessen Jürgensen A/S er med på Danske Køledage, stand nr. 40.

    For at fremme de mest energie! ektive varme-pumper har Energistyrel-sen i Danmark oprettet en o" ciel, men foreløbig oversigt over energimær-kede varmepumper.

    Listen vil løbende blive udbyg-get efterhånden som produ-center og leverandører får fremsendt den nødvendige do-kumentation, oplyser styrel-sen.

    Oversigten indeholder data for væske-vand varmepumper og luft-vand varmepumper, og skal hjælpe forbrugere med at fi nde de mest energie! ektive varmepumper.

    Listen fi ndes via styrelsens hjemmeside, www.ens.dk.

    Energie! ektiviteten for en varmepumpe afhænger af fl e-re forhold. Bl.a. spiller tempe-raturforskellen mellem varme-opsamler (f.eks. jordslanger) og fremløbstemperaturen på

    varmeafgiver (radiatorsyste-met) en stor rolle.

    For at tage højde disse tem-peraturforhold indeholder oversigten oplysninger om norme! ektiviteten. Da frem-løbstemperaturen til radiato-rer typisk er højere end frem-løbstemperaturen til gulvvar-me er der på oversigten er op-givet en norme! ektivitet for henholdsvis radiator- og gulv-varme. Ved beregning af nor-me! ektiviteten er der ved brug af danske klimadata taget høj-de de forskellige driftstilstan-dene som varmepumpen vil komme ud for i Danmark.

    Energistyrelsens liste for energimærkede varmepumper er opdelt i kategorier efter var-mepumpernes e! ektydelse. Det er vigtigt, at vælge en var-mepumpe der passer til beho-vet.

    Derudover er listen opdelt på væske/vand varmepumper (jordvarme) og luft-vand var-

    mepumper. For luft-luft var-mepumper henvises der til Teknologisk Instituts godken-delsesordning som desuden omfatter brugsvandsvarme-pumper. Derudover har Elspa-refonden en positivliste for luft-luft varmepumper egnet til sommerhuse.

    Dimensionering vigtigEnergistyrelsen gør opmærk-som på, at det er ikke nok at vælge en energie! ektiv varme-pumpe. Det er meget vigtigt, at varmepumpen er dimensio-neret til det behov den skal dække.

    „Find derfor en rådgiver/installatør du føler dig tryg ved og få lavet beregninger for net-op dit hus”, lyder rådet fra sty-relsen.

    Brugsmønster og installati-onsforhold har også betydning for varmepumpens energief-fektivitet. Ved dimensionering af varmepumpen er det vig-

    tigt at tage disse forhold med i betragtning, for at sikre, at det er den rigtige pumpe der in-stalleres i det pågældende hus.

    For at øge muligheden for at tage sådanne forhold med i betragtning gennemføres der i 2009 et omfattende målepro-gram af varmepumpers e! ek-tivitet ude hos den enkelte for-bruger over året. Desuden vil der blive sat fokus på, hvilke initiativer der kan iværksættes for at øge kvaliteten i installa-tørernes arbejde.

    Sidst men ikke mindst vil der blive udarbejdet informa-tionsmateriale rettet mod for-brugere, der overvejer at inve-stere i en varmepumpe.

    Varmepumper optages på Energistyrelsens liste over mærkede varmepumper efter ansøgning. Producenter og le-verandører af varmepumper kan rekvirere ansøgningsma-teriale hos Energistyrelsen.

    Energimærkning af varmepumper

  • 10 [ScanRef . 1 . February 2009]

    NE

    WS

    GEA Ecofl ex, one of the leading suppliers of plate heat exchangers (PHEs), has reduced delivery times for certain gasketed PHEs to 7 days with its new fast-assembly line.

    With the NT 50 and the NT 100 from the successful NT Se-ries the new express line o! ers two model ranges that are mostly standardised and spe-cially developed for use in the expanding HVAC sector.

    The fast delivery provides plant engineering companies with the necessary planning se-curity to be able to reliably im-plement projects at short no-tice.

    The construction of its new production hall in Sarstedt a year ago was the fi rst stage by GEA Ecofl ex to pave the way for the fast-assembly line.

    In the following months engi-neers looked into the standard

    demands placed on PHEs by plant engineering companies across a wide variety of appli-cation fi elds.

    This information was used in the standardisation of the two model ranges NT 50 and NT 100 and in defi ning the key technical data. The pressure-bearing frames are designed for up to 16 bars at a maximum temperature of 140ºC.

    The 0.5 millimetre thick plates are made of high-quality special steel (1.4404 / AISI 316). Both model ranges will be available in three plate lengths (T, M, X).

    The NT 50 is supplied with a 2” external thread to DIN 2999, whereas the NT 100 is fi tted with a ND 100 fl ange connection to DIN 2633.

    The fi xed nominal connec-tion diameter results in a maxi-mum volume fl ow of approx. 40 m3/h with the NT 50 and approx. 170 m3/h with the NT

    100. NBR or EPDM gaskets are fi tted as standard.

    The success of the fast-as-sembly line is based on an inde-pendent manufacturing proc-ess, combined with a modular product concept.

    The components are prefab-ricated in specifi c batches inde-pendent of customer orders.

    After the customer has placed the order the required compo-nents are assembled in the de-sired confi guration, subjected to a fi nal pressure test and dis-patched within a matter of days (maximum seven).

    The technical specifi cations allow a wide application fi eld; from heating, air conditioning and surface technology via in-dustrial refrigeration up to solar and heat pump engineering. In addition the NT range is ideal-ly suited for use in system sepa-ration, e.g. as an oil cooler.

    Finally the plate heat ex-changers from the fast-assem-

    Ecofl ex even faster

    bly line guarantee dependable process reliability for cooling or heating of non-aggressive me-dia, as aggressive media require special materials.

    GEA Grenco Køleteknik A/S har installeret en 2,0 MW isvandskølecentral på ingrediensfi rmaet Chr. Hansens nye fabrik på Avedøre Holme i København.

    Isvandskølecentralen er etable-ret i forbindelse med en ny fer-menteringsfabrik ved Chr. Hansens produktions faciliteter.

    Kølecentralen forsyner fer-menteringsfabrikken med is-vand ved en temperatur på 2,5ºC og har pt. en maksimal køleka pacitet på 2 MW.

    Kølecentralen er konstrueret

    Isvandskølecentral med frikølingmed en minimering af energi-forbrug for øje, dvs. anlægget driftsoptimeres kontinuer ligt som funktion af den aktuelle belastning fra kølefor brugere samt omgivelsestemperatur, så-ledes at anlæggets totale e! ekt-optag til stadighed er overvåget og reduceret til et praktisk mi-nimum.

    Det betyder, at anlægget an-vender frikøling som delkøling af varmt returkølevand fra fermete ringsprocessen når det er muligt, og efterkøler køle-vandet til fermeteringsproces-sen med vand køleaggre ga terne.

    Frikølingen foregår ved hjælp

    af en pladevarmeveksler, som veksler mod et af de to køletår-ne, som ved vandfordampning bortleder varmen fra frikølings-processen.

    Køletårnene, der også anven-des til bortkøling af vandkøle-aggregaternes kondensatorvar-me, regu leres således, at set-punktet på den udgående vand-temperatur tilpasses den aktuel-le lufttemperatur og relative fugtighed.

    Kølecentralen er bygget op af:! 2 stk. identiske GEA Grasso

    FX GC PP 1050-2 vand-køleaggre gater, med hver en nominel kapacitet i design-punktet på 970 kW.

    Hvert vandkøleaggreagat er af såkaldt „fl ooded” type og er forsynet med: ! 1 stk. GEA Ecofl ex LWC pla-

    devarmeveksler fordamper. ! 1 stk. GEA Ecofl ex LWC pla-

    devarmeveksler kondensator.! 2 stk. GEA Grasso 810 stem-

    pelkompressorer, hvoraf en er drevet ved fast omløbstal, og den anden er forsynet med vari abel Speed Drive.

    ! 1 lokal styre- og e! ekttavle forsynet med intern PLC.

    Desuden består anlægget af:! 2 stk. identiske GEA Polacel

    XT 2720 køletårne fremstil-let såle des, at alle væskebe-rørte dele er fremstillet i en kombination af GRP (glas-sfi bre reinforced platic) og rustfast stål, hver med en no-minel kapacitet i designpunk-tet på 2,4 MW.

    ! 1 stk. GEA Ecofl ex NT frikø-lepladevarmeveksler.

    ! 8 stk. rustfaste vandcirkulati-onspumper, som alle er forsy-net med frekvensomformere.

    ! 1 stk. termisk bu! ertank på 100 m3.

    ! Kombineret RO-anlæg for køleinstallation og kedelan-læg.

    ! 1 stk. PLC system styring for energirigtig styring af anlæg-get.

    ! E! ekttavler og frekvensom-formere for regulering af an-læggets delkomponenter.

    ! Rustfri vandrørsinstallation, hvor anlæggets isvandsrør og termiske Bu! ertank er isole-ret med aluminiumsinddæk-ket PUR skum.

  • „Hurtig montage – kondensator GVX.“

    Den nye kondensator GVX med microox®-teknologi. Leading with smart systems.

    – Nem og hurtig montage med montageliste– Fås med omfattende tilbehør – Ventilatorer kablet fra fabrik til arbejdsafbryder og styreenhed

    Nærmere informationer på: www.guentner.de

    Güntner AG & Co. KG Sales Office ScandinaviaJulsøvej 1, 1 sal8240 RISSKOVDENMARKTel.: +45 70 2706-99

    ...keep(s) your quality.

  • 12 [ScanRef . 1 . February 2009]

    NE

    WS

    Det är åter igen dags för Djupfrysningsbyråns årliga utbildning kring den obrutna kyl- och fryskedjan.

    Utbildningen riktar sig till alla i värdekedjan som vill öka sina kunskaper kring och få praktis-ka tips om åtgärder för att mini-mera riskerna med temperatur-läckage och därmed försämrad kvalitet för konsumenten.

    Ett helt nytt avsnitt kring kli-matfrågan och den nuvarande statusen i ämnet är adderat.

    Kursen startar på eftermid-dagen den 30 mars och avslutar kl 16.00 den 31 mars 2009. Ut-bildningen kommer att hållas i Stockholmstrakten.

    Bland utbildarna möter du Göran Löndahl, med mångårig erfarenhet av djupfrystteknik och hur man undviker problem

    i kyl- och fryskedjan samt Alex-ander Milanov från SIK som vet allt om mikrobiologi och hur man undviker mikrobiolo-giska risker i livsmedlen.

    Bryter man kyl- och frysked-jan kan det leda till oanade kon-sekvenser för konsumenten och företagets varumärke. Vidare närvarar en expert på området miljö och klimat som redogör för den aktuella statusen i frå-gan.

    I undervisningen ingår ett ut-bildningsmaterial i form av en pärm som fungerar som upp-slagsverk. I år får du dessutom den nya bok „Allt om djup-fryst”.

    Antalet deltagare är begrän-sat till 40 personer.

    Skicka gärna din intresseanmälan till [email protected].

    Kurs om den obrutna kyl- och fryskedjan

    Presents lowest environ-mental impact commer-cial refrigeration solutions at cholod expo trade show.

    Embraco, the world leader in the hermetic compressor mar-ket for refrigeration, will present its entire line of commercial refrigeration products at the Cholod Expo Rossija trade show, in Moscow, Russia be-tween March 10 th - 12th 2009.

    As a reference in the region, the trade show will help strengthen Embraco’s image in

    Embraco at Moscow-fairEastern Europe. Embraco’s presence in this market has been growing steadily especial-ly in Russia where the Embraco enjoys a market share in the commercial refrigeration seg-ment of 30%.

    Embraco continues to bring solutions that are still more e" -cient and compatible with envi-ronmentally advanced fl uid re-frigerants.

    During the exhibition, these new products will be on dis-play.

    One of them is the EK com-pressor, targeted for medium-

    size commercial cabinets for use in low and high tempera-ture applications. This family uses carbon dioxide (CO2) as a refrigerant fl uid.

    Together with the NEK com-pressor, Embraco will present the new compact EMT models for commercial applications available for use with R290, R404a and R134a.

    The recently launched NT models cover the top range of the cooling capacity. This fami-ly contains the high e" ciency solutions that Embraco has de-veloped, allowing the manufac-turers to meet the new stricter regulations for energy con-

    sumption, which go into e! ect in Europe in 2011.

    The NT family is 15% more energy e" cient than the stand-ard products and it has lower noise and vibration.

    This family has models for use with R404A, R134a and R290.

    At the Cholod Expo, Embra-co will also present sealed com-plete cooling systems for refrig-eration.

    With the pre-assembled and sealed systems, the customer has many benefi ts including the possibility to simplify his pro-duction, when sourcing the complete refrigeration system.

    Embraco at Chillventa 2008. Photo: Per Jensen, ScanRef.

    Norway exported seafood worth NOK 4.9 billion in October 2008, an increase by 26 per cent, compared with the same month last year.

    In 2008 Norway has exported seafood worth NOK 31 billion, an increase by 6 per cent, com-pared with the same period in 2007, and also a new record.

    The export of salmon in Oc-tober increased by 6 per cent to

    60,000 tons. For trout the incre-ase was a whooping 25 per cent to 7.500 tons.

    France and Poland are the biggest importers of salmon, while Russia and Japan are the major importers of trout. '

    The export of stockfi sh in-creased by 20 per cent in Octo-ber.

    Source: European Cold Storage and Logistics Association.

    Record on Seafood Exports

    Færre udstiller på køledageDet ser ud til at der i år bliver lidt færre udstil-lere end tidligere på Danske Køledage, som gennemføres i Odense Congres Center 12-13. marts.

    Dansk Køledags nye direktør Lisbeth Groth Haastrup fort-sætter dog bestræbelserne på at få standene fyldt op.

    Adgangsbilletter til udstil-lingen udleveres gratis. Ud-stillerne kan udsende ad-gangsbilletter til kunder.

    Invitationen til konferen-cen med udstillere og pro-gram bliver udsendt til fl ere

    end 4.500 personer inden for o! entlige myndigheder, in-dustrien og rådgivende inge-niører.

    Desuden kan udstillerne sende invitationer til deres kunder.

    Firmapræsentationer af produkter foregår sideløben-de med konferencen. De vil blive markedsført på samme vilkår som øvrige indlæg på konferencen.

    Med virkning fra 15. januar 2009 har DuPont øget prisen for kølemidlet Freon 22 HCFC i Europa med 20%, oplyser sel-skabet.

    Firmaets europæiske salgs-chef Gonzalo Alonzo begrun-der prisforhøjelsen med be-grænset udbud og højere priser på de anvendte råmaterialer.

    Prisen for freon øget med 20%

  • [ScanRef . 1 . February 2009] 13

    NE

    WS

    Energioptimering af køleanlæg, anvendelse af naturlige kølemidler, ener gimærkning og varmegenvinding for klimaanlæg, samt udvik-ling af nye mini-varme-pumper til lavenergi-huset.

    Det er blot nogle af de mange emner, der tages fat på i det fag-lige program under Danske Køledage i Odense Congres Center 12.-13. marts.

    Energi og miljø er således fortsat i fokus i den danske køle-branche, hvilket også under-streges af valget af hovedtaler ved åbningen, nemlig forman-den for Folketingets Miljø- og Planlægningsudvalg, Steen Ga-de, Socialistisk Folkeparti.

    Han var også direktør for Miljøstyrelsen i perioden 1999 til 2003.

    Den faglige hovedtale leveres af Kjeld Stærk, der sidste år blev udpeget som President for

    Danfoss Refrigeration & Air Conditioning Division.

    Han suppleres af et måske mere underholdende indlæg af meteorolog Jesper Theilgaard fra Danmarks Meteorologiske Institut, der er forfatter til fl ere bøger om vejrfænomener.

    Han skal berette om „Klima-ændringer – vildt vejr og orka-ner i baghaven”.

    Det faglige program gen-nemføres begge dage i tre pa-rallelle spor.

    Torsdag er der fi re indlæg for rådgivere, tre for installatører og fi re for forskere og udviklere. Fredag er der fi re indlæg, hvor temaet er kølemidler, og samti-digt fi re indlæg, hvor temaet er ventilation og køling.

    Fredag formiddag gennemfø-res tillige et minikursus om di-mensionering af en vandbase-ret, sekundær kølekreds.

    I lighed med tidligere år gen-nemfører Den jyske Haandvær-

    kerskole det traditionelle DM i Køleteknik, hvor vinderen kå-res fredag eftermiddag.

    Og lige som sidste år gen-nemføres torsdag i samarbejde med Syddansk Universitet en konkurrence blandt udvalgte studerende i design af kølean-læg.

    Vinderen kåres ved afstem-ning blandt publikum.

    Deltagelse i de faglige semi-narer koster for begge dage kr. 2.950. Torsdag alene koster kr. 2.125, fredag alene kr. 1.150, mens deltagelse i festen torsdag aften koster kr. 750.

    Der er reducerede priser for lærlinge, studerende og pensio-nister.

    Tilmeldingsfristen er 6. marts og kan ske via www.dansk-koeledag.dk.

    Danfoss President Kjeld Stærk (t.h.), her fra Chillventa 2008 i Nürnberg. Foto: Per Jensen, ScanRef.

    Fortsat fokus på energi og miljø

    På KTF´s föreningsmöte i Göteborg informerade Kylma om förändring i sitt komfortprogram.

    När svenska Kyltekniska Fören-ingens Göteborgsavdelning höll sitt första föreningsmöte för året, som för övrigt handlade om nya normer och bestäm-melser, passade kvällens värd Kylma på att berätta om de för-ändringar som gjorts under hösten/vintern.

    En av de stora nyheterna var att man från Clima Sverige AB tagit över all försäljning av Mitsubishi Heavy Industries (MHI) komfortprodukter till hela branschens installations-led. Båda företagen ingår i Bei-jer Ref. Därmed ökas fokuse-ringen på komfortkyla och den lokala närvaron av MHI´s pro-dukter i Sverige.

    Clima Sverige AB koncentre-rar framgent sin verksamhet till bl a Echo Dry sorptionsavfuk-

    tare samt utveckling av luft/vatten värmepumpen Echo In-verter och då med speciell in-riktning mot byggvaruhandeln. Echo Inverter kommer tills vi-dare att säljas parallellt av Kyl-ma.

    Personalökning!Den personal som ansvarat för teknisk försäljning och teknisk support av MHI´s produkter följer med och är numera Kyl-ma-anställda. Arbetsort blir som tidigare Ängelholm men med ansvar mot alla Kylmakun-der i Sverige.

    Kylbranschen får härmed tillgång till ett komplett sorti-ment av såväl Mitsubishi Heavy Industries som Aermecs pro-dukter hos samtliga Kylma-kontor.

    Komfortprogrammet inrym-mer idag allt från små fl äktkon-vektorer till stora vätskekylare inom e! ektområdet 1kW - 1,5 MW.

    Kylma övertar Mitsubishi Heavy

    l a t e s t n e w s : w w w . s c a n r e f . c o m

  • 14 [ScanRef . 1 . February 2009]

    NE

    WS

    " Av Anders Lindborg Ammonia Partnership

    US EPA föreslår mer aktiva förbud att använda ozon-för-störande köldmedier av HCFC typ som R 22 och R 142b från 2010.

    USA har hittills följt den o" -ciella tidsplanen i Montreal protokollet att avveckla CFC och HCFC som t.v. tillåter an-vändning av R 22.

    Tidplanen är avsevärt mer generös än vad övriga västvärl-den följer. Europa har olika för-bud i kraft och som kommer att träda i kraft 2010. Hittills har USA fortfarande kunnat im-portera och producera R 22 och R 142b för service och un-derhåll samt utrustningar för-fyllda med de aktuella köldme-dierna. Från början av 2009 in-förs nya importförbud av dessa köldmedier i prefabricerade ut-rustningar. Kvar blir att de ak-tuella köldmedierna bara får fyllas på för service och under-håll. Total användning upphör 2020.

    (www.R744.com)

    International Institute of Ammonia Refrigeration (II-AR) i USA har hittills liksom Eurammon i Europa varit för-svarare för användning av am-moniak. Eurammon har bred-dat sina aktiviteter till att gälla naturliga köldmedier allmänt och det har nu även tagits upp av IIAR.

    Man satsar speciellt på CO2 men även andra alternativ och på att US EPA föreslår att USA skall påskynda utfasningen att använda R 22.

    Man har skapat en aktion för att göra myndigheter, påverk-ningsgrupper, industri och all-mänhet medvetna om Naturli-ga köldmedier… lämna inga fotavtryck. Passa på tillfället att ersätta R 22 med miljövänliga köldmedier såsom ammoniak och koldioxid.

    (www.R744.com)

    General Electric har genom en Press Release låtit meddela att man önskar börja tillverka kyl- och frysvaror med isobutan (HC) som köldmedium och pentan som drivgas i skumning av isolering.

    Man vänder sig till US EPA för godkännande och planerar en begränsad marknadsföring. Som grund anger man att vilja reducera användningen av HFC medier som R 134a i köldmediekretsen och R 141b som drivgas i isoleringen och därmed växthusgaser.

    I Europa och Asien fi nns se-dan många år mer än 100 mil-joner kylskåp med de föreslag-na medierna och erfarenheten är god.

    I USA har det hittills varit omöjligt att föreslå dessa medi-er då kommersiella krafter mot-verkat användningen av natur-liga medier och man räds dyr-bara rättsliga processer om olycka skulle hända.

    GE bedömer sannolikt att HC medier ger billigare pro-duktion och mer konkurrens-kraftiga produkter. Denna för-ändring kan leda till att andra tillämpningar även omprövas med naturliga köldmedier och kanske nästa steg för bilindu-strin.

    Mobil AC (MAC) måste stäl-la om sig från nuvarande R 134a till media med GWP

  • [ScanRef . 1 . February 2009] 15

    DuPont har gjort en studie på R 22 som visar att inom 9 större nationer inom EU är fortfarande 65% av kylinstalla-tioner använder HCFC medi-er.

    Man ifrågasätter om mark-naden är förberedd inför 2010 då endast återanvänt köldmedi-um får fyllas på vid service.

    Ännu använder inom indu-striella tillämpningar 61% av frysrum och ca 57% av chillers HCFC. Även om de fl esta slut-användare är medvetna om nya bestämmelser så kommer många att avvakta och hoppas att återvunnen HCFC kan hjäl-pa dom.

    Mann bedömer att inom EU fi nns fortfarande 130.000 ton HCFC i kylsystem och man av-vaktar till slutligt förbud 2015 och det bör fi nnas stora mäng-der R 22 att återvinna.

    DuPont har i sin information www.isceon.com listad alla sina köldmedier men en del av dessa har ODP och en del innehåller HCFC, några PFCI). Alla har mer eller mindre GWP. I) Perfl uorkarboner med stort GWP.

    (Refrigeration World N 5, Dec. 2008)I Svensk Kylnorm har man se-dan många år listad köldmedier och markerat alla medier som innehåller CFC/HCFC för att tydliggöra vilka medier som bör/skall undvikas.

    Denna markering borde ha införts inom Europa och då ha-de installatörer och slutan-vändare kunnat se innehåll av CFC/HCFC i olika köldmedi-er och blandningar.

    HC läckage i fryshus förorsa-kade storbrand och dödsfall.

    5 april 2009 inträ! ade en storbrand på Icepak Cooldsto-res, Tamahere, New Zealand. Man hade sedan fl era år kylin-stallation med R 22 och i en miljöambition 2003 konverte-rades till naturliga köldmedier byte av R 22 till R 290 propan.

    Detta gjordes okunnigt utan att följa de säkerhetsstandarder som förekommer i Europa och många andra länder.

    Ett gaslarm fi ck lokalt brand-försvar att besöka maskinrum-met och några personer gick in.

    Där kunde man konstatera att en förskruvning på en kom-pressor (sannolikt en fl are-kopp-ling) läckte. Efter några minu-ter startade en brand och det är inte helt klarlagt vad som var tändkällan.

    En brandman omkom och fl era fi ck svåra brännskador och en brandbil totalförstördes.

    Hela fryshuset brann ner på några timmar.

    Det fi nns rapport på händel-seförloppet utgiven av New Zealand Fire service.

    (www.fi re.org.nz)

    Tank med ammoniak åter-vände till jorden på naturligt sätt under juli 2007.

    International Space Station (ISS) har fem system vardera med 350 kg ammoniak och un-der 2001 hade man tagit upp extra köldmedium.

    Då systemen är täta behöv-des inte extra fyllning 2006 och tanken släpptes ner.

    Den landade i havet mellan Australien och Nya Zeeland.

    (NASA)

    En ammoniakanläggning i Brunei på Sumatra installera-des nyligen av ett företag från Thailand.

    I samband med provtryck-ning av det nya systemet använ-des luft eller annan gasbland-ning som innehåller syre.

    Detta förorsakade en explosi-on som dödade tre personer. Det är inte bara ammoniak som under närvaro av syre under tryck kan bringas att explodera om det fi nns en tändkälla.

    Det gäller alla ämnen som innehåller väteatomer (H) t.ex R 22, R 134a m.fl .

    Sådana olyckor har inträ! at fl era gånger i USA, Syd-Afrika, Europa. Orsak till olyckan kan ha varit att man slarvar med anslutningar på tryckfl askor.

    Det skall vara olika anslut-ningar för kväve, luft, syre osv.

    (Egen korrespondens)

    Svensk Kylimport AB Energigatan 17, 434 37 Kungsbacka

    Tel. 0300 56 68 85 - Fax. 0300-56 68 25 Hemsida: www.skiab.com E-mail: [email protected]

    -SPINCHILLER- en energieffektiv och flexibel aggregatserie

    !" COP över 6,0 vid dellast !" Med eller utan integrerad pumpsektion !" Luftkylt R-410A eller R-407C !" Vätskekylt med R-407C !" 4-12 scrollkompressorer !" 170-1000 kW i kylutförande !" 200-500 kW i värmepumpsutförande !" Lågtemperatur ner till -8°C KB !" Frikylningsfunktion !" ECO-BREEZE fläktar

  • 16 [ScanRef . 1 . February 2009]

    RE

    PO

    RT

    S

    ClimaChecks metod för energie! ektivisering har nått internationella framgångar.

    " Text och foto Olle Dahlberg

    Innovationen från ClimaCheck Sweden ligger rätt i tiden!

    Att produkten rönt stort in-ternationellt genomslag är inte förvånande eftersom hela värl-den talar om behovet av sats-ningar på energibesparing för att möta klimathotet och mot-verka lågkonjunkturen. Vilken nytta gör då den svenska pro-dukten ClimaCheck i detta sammanhang? Och vilka är målgrupperna?

    Som första system i världen erbjuder ClimaCheck möjlig-het att koppla in i princip vilken kylprocess som helst för doku-mentation av prestanda till rim-lig kostnad. Den avslöjar bl.a. kompressorfel, felinställd ex-pansionsventil, brist på under-kylning, fel på styrsystem, felak-tig mängd köldmediefyllning och visar givetvis COP (Coe" -cient of Performance) som är ett mått på hur energie! ektivt aggregatet är.

    Detta erbjuder möjlighet ve-rifi era både energie! ektivitet och bl.a. att aggregatet uppfyl-ler de krav som ställdes vid upp-handlingen.

    Kylsystem kan optimeras med omedelbar dokumentation av resultatet.

    Världens kyl- och värme-pumpanläggningar beräknas förbruka 15-20% av all energi och utgör en enorm besparings-potential för såväl den enskilde husägaren som elbolag och samhället i stort.

    Miljöpåverkan kan enligt ett

    examensarbete på KTH mins-kas med i snitt 10% och risken för haverier med stora kostna-der begränsas.

    MålgrupperTveklöst ett självskrivet instru-ment för de prestandainspek-tioner, som enligt lagen skall ingå i energideklarationerna och för att dokumentera pre-standa och funktion i samband med slut- och garantibesikt-ningar. Dessutom ett e! ektivt hjälpmedel för både kylentre-prenörer och brukare av kyl- och värmepumpsystem.

    ClimaCheck erbjuder stora besparingar inom livsmedelsin-dustrin, hos livsmedelskedjorna och för att inte tala om kom-mersiella fastighetsägare, som nu också är skyldiga ta fram en-ergideklaration för alla sina fastigheter.

    En annan specifi k målgrupp utgör datacentraler och idrotts-anläggningar med stora energi-förbrukningar och krav på drift utan avbrott.

    Många tillverkare har också insett att ClimaChecks system kan e! ektivisera deras produkt-utveckling och produktionstes-ter. Man löser enkelt och snabbt ev. diskussioner om pestanda el-ler funktion efter leverans.

    Flera nyttjar ClimacheckClimaCheck har levererats till fl er hundra svenska entrepre-nörer och anläggningsägare. Norrenergi AB är ett exempel på företag som integrerat ClimaCheck i sin driftövervak-ning.

    Företaget producerar och säl-jer fjärrvärme och fjärrkyla till kunder inom Solna och Sund-byberg.

    Vid besök hos Norrenergi AB tog Driftchefen Lars Olrin emot och informerade om företaget, som är ett av landets största le-verantörer av fjärrvärme och fjärrkyla. Han berättar:

    Norrenergis fjärrvärme är märkt med „Bra Miljöval”, vil-ket understryker företagets sats-ning för en grönare framtid. Fjärrvärmen produceras i vär-mepumpar och värmepannor där råvaran är bl. a. förnyelse-bara pellets och briketter, som kommer med järnvägstransport från Sveg och lastbilstransport från egna lager i Hargs hamn. Produktionsprocessen är i det närmaste helautomatisk.

    Under år 2007 levererades 63 GWh fjärrkyla och 1031 GWh fjärrvärme.

    Som ett led i miljöarbetet in-stallerades nyligen Climacheck för att ge underlag för energi-optimering och öka driftsäker-heten på värmepumpanlägg-ningen, som är en platsbyggd ABB Finspång-installationen från mitten av 1980-talet är för-delad på fyra värmepumpar.

    De är bestyckade med var sin tvåstegs turbokompressorer. Två värmepumpar har tubför-ångare och två har strilförånga-re. Den totala värmee! ekten är c:a 100 MW. Anläggningen är konverterad från köldmedium R22 och R500.

    Har sparat miljonerVid drifttagningen av Clima-Check visades onormala drift-förhållanden på värmepump 2.

    Vid analys av processdata framkom tydliga signaler på att aggregatet arbetade på lägre tryck än tryckmätningarna vi-sade och kompressorn arbetade med „fuktig” suggas, vilket var

    fullt tillräckligt för att markant påverka kompressorarbetet.

    Efter noggrann kontroll av alla mätvärden togs beslut om renovering av det aktuella vär-mepumpsystemets förångare. Demontering av „demistern”, som skall förhindra kölmedium i vätskefas att nå kompressorn, visade att den var defekt. Detta medförde stort tryckfall efter mätpunkten samt medryckning av vätska och därmed risk för impeller-skada.

    Renoveringen resulterade i lägre tryckfall motsvarande en kapacitetshöjning på i storleks-ordningen 3 MW eller 10-15% och eliminering av vätske-medryckningen.

    Uttryckt i pengar rör det sig om miljontals kronor per år i besparing. Investering i Climacheck för alla fyra aggre-gaten inklusive anpassningar och utbildning rör sig om „kaf-fepengar”, i sammanhanget c:a SEK 60.000:-

    Samarbete med Carrier ABClimaCheck har tillsammans med ett av världens ledande fö-retag i branschen, Carrier Cor-poration, utvecklat en special-anpassad version av Perfor-mance Analyser för Carriers aggregat. I ClimaChecks Per-formance Analyser integreras kommunikationskort med Car-riers system vilket förenklar prestandamätning.

    Jan Börjesson, servicechef, Carrier AB:

    „Vi använder den främst i ar-betet med att e! ektivisera kyl- och värmepumpanläggningar. Genom att på ett enkelt sätt koppla in sig i köldmediesyste-met för avläsning av anlägg-ningens status kan teknikern

    Övervakningscentralen på Norrenergi med integrerad ClimaCheck.

    Driftchef Lars Olrin, Norrenergi i Värmepumpcentralen.

    Energibesparing som exportvara

  • [ScanRef . 1 . February 2009] 17

    snabbt komma igång med sitt arbete och får en tydlig över-blick av funktionen. Att även få information från omkringlig-gande system, som påverkar köldmediesystemet gör det en-kelt för en erfaren tekniker att utföra och dokumentera de jus-teringar, som krävs”.

    „ClimaCheck är alldeles ut-märkt som verktyg vid felsök-ningar m.m. Performance Ana-lyser är snabbare att koppla upp men även både noggran-nare och tillförlitligare vid mät-ning jämfört med de vanliga in-strument en kyltekniker använ-der. Detta medför att även små men betydelsefulla avvikelser upptäcktes och kan åtgärdas”.

    Jan Börjesson fortsätter: „Flertalet anläggningar sak-

    nar installerad utrustning för fl ödes- eller e! ektmätningar. Performance Analyser kommer här till sin fulla rätt, särskilt som dess noggrannhet överträ! ar konventionella metoder. Att koppla upp Performance Ana-lyser vid drifttagning av nya an-läggningar säkerställer att an-läggningen från början blir rätt injusterad. Ovärderligt för bå-de beställare och entreprenör. Minskad risk för driftavbrott och garantiärenden.

    ClimaCheck – en given exportproduktProdukten introduceras nu suc-cessivt på nya marknader och har stora framgångar i Storbri-tannien och Australien. Den nya tekniken accepteras nu i allt snabbare takt och lanse-ringen fortsätter i fl era länder med särskild fokus på Europa, som har tydliga krav på pre-standainspektioner.

    Klas Berglöf berättar:

    „Välkända livsmedelskedjan Tesco använder nu ClimaCheck som ”prestanda–analysator” för fältmätningar på deras nya butiker där de vill jämföra olika systemlösningars prestanda.

    Utöver ClimaCheck var det endast stora, välkända företag som gick vidare till fi nalen. och fi ck hedersomnämnande Övri-ga var Copeland, EBM-Papst, Baltimore och Artic Circle.

    Slutlig vinnare blev världens största kompressortillverkare Copeland för sin ”Digital Scroll. ClimaCheck var med andra ord i gott sällskap!

    Ett annat exempel är Cam-bridge University, som efter de-monstration nu beställt både portabel och fast installerad ClimaCheck.-utrustning.

    Universitetet köper årligen el för £12 millioner varav 50% uppges används för drift av c:a 100 st stora lutkonditionerings-aggregat och ett stort antal mind re kylaggregat. Man insåg genast en stor besparingspoten-tial med ClimaCheck när den första demonstrationen på ett slumpmässigt valt aggregat vi-sade att de bara på detta ensta-ka aggregat kunde spara 15% av elförbrukningen med enkla och mycket kostnadse! ektiva optimeringsåtgärder.

    ClimaCheck lanserar nu tredje generationens prestanda analysatorer ClimaCheck PA Pro med ett antal nya funktio-ner, som ger nya möjligheter för fast övervakning över Internet och kommunikation med olika aggregats styrsystem.

    Följ utvecklingen på: www.climacheck.com

    Jan Börjesson. Foto Carrier AB.

    Allt du behöver!

    För att hitta ditt närmaste DahlCenter gå in på dahl.seRing oss gärna på 08-583 595 00 eller maila på [email protected]

    Dahl är Sveriges ledande handelsföretag inom VVS, Mark&VA, Industri, Kyla och Fastighetsförnödenheter. Du hittar även verktyg och förbrukningsvaror hos oss.

    I vårt produktsortiment Kyla hittar du produkter för professionella kylinstallationer.

    Vi har produkter för bland annat:

  • 18 [ScanRef . 1 . February 2009]

    RE

    PO

    RT

    S

    Kyldelar AB i Malmö passar på att fi ra 3-årsju-bileum och samtidigt fl ytta till större och ändamåls-enligare lokaler.

    " Text och foto: Anders Hiorth

    Grossistföretaget Kyldelars VD och tillika ensamägare, Anders Ekbladh, kan se fram emot en mycket rationellare och trevli-gare kund- och arbetsmiljö efter fl ytten från Oxie, då ca 15 km sydost om Malmö, till tre gång-er så stora lokaler, numera på Fosie Industriby inne i Malmö.

    „Vi märkte direkt vad mycket det betydde att komma närma-re kunden”, säger Anders Ek-bladh vid rundvandringen i det välfyllda lagret vid vårt besök i slutet av november 2008. ”Det märks inte minst på butiks- och innesäljarpersonalen som via dessa butiksbesök bygger upp en starkare kundrelation än ti-digare. Även om vår omsätt-ning har ökat hela tiden sedan jag övertog företaget, så är det enklare att stärka kundrelatio-nerna nu när man kan visa pro-dukterna så att säga över disk” tillägger Anders.

    Kyldelar har i skrivande stund 5 anställda och omsätter ca 12 miljoner kronor.

    Framgångsrik produkt-pallettBland Kyldelars förhållandevis breda produktsortiment märks en klar inriktning mot produk-ter med stort teknikinnehåll. Som exempel kan nämnas Ref-komp kolv- och skruvkompres-sorer där man lagerlägger stor-lekar upp till 154 m3/h.

    Vätskekylare kan man levere-ra i praktiskt taget alla utföran-de och storlekar och för speciel-la behov bygger man också kundanpassade ramaggregat och pumpmoduler.

    Likaså levererar man för vil-labruk värmepumpar i utföran-de luft/luft, luft/vatten och vat-ten/vatten i e! ektområdet 3-20 kW, och s.k. fastighetsvärme-pumpar på över 1,5 megawatt.

    Senaste kompressor-teknikenFörutom ismaskiner och evapo-rativa kondensorer är nog den intressantaste produktgruppen den som innehåller enhets- och delade aggregat samt „con-

    densing units” från Zanotti. Från denna stora Italienska le-verantör fi nns allt från små kompaktaggregat för mindre kyl- och frysrum, (som man fak-tiskt också har på programmet), via riktigt rustika industrikylag-gregat där man kan växla från kyl- till frys beroende på sä-song.

    Ur Zanotti-programmet kan man också välja om man vill ha en- eller fl era kompressorer, hel- eller semihermetiska, kolv- eller scroll, fastvarvtal- eller in-verterstyrda, standardvarvtal- eller lågvarviga fl äktar för läg-sta ljudnivå.

    „Inte minst detta med inver-terstyrda kompressorer i ”con-densing units” är riktigt intres-sant. Här har Zanotti lyckats konstruera en ny och mycket fl exibel aggregatserie. Om vi tar ett exempel på kylapplika-tion, dvs. förångning -10ºC och R-404A, så kan man med sam-ma aggregat täcka ett område från 6,6 till 16,6 kW! Man stäl-ler bara in ett önskat sugtryck eller en önskad temperatur så anpassas vartalet på den inver-terstyrda kompressorn från Danfoss, och därmed kapacite-ten mellan. 30 och 90 Hz”, för-

    Grosshandlare Ekbladh i egen hög person.

    Välfyllt lager, hög beredskap, stor tillgänglighet.

    Liten grossist med stort kunnande

    tydligar Anders när han förevi-sar aggregatet. Tänk vad un-derbart enkelt, man ställer in den förångningstemperatur man han dimensionerat an-läggningen för och kompres-sorn anpassar kapaciteten efter det för stunden aktuella beho-vet!

    FaktarutaKyl- & Frysrum av fabrikat IN-STAKLACK, moduluppbygg-da, patenterat låssystem, tät-ningslister i stället för silikontät-ning, lätta att montera och de-montera, hyllsystem i aluminium eller rostfritt.

    Lagerlagda kompressorer från 3 cm3 till 154 400 cm3. De stora kompressorerna fi nns i många importerade aggregat, Kyldelar betryggar den efter-marknaden.

    Komponenter „line compo-nents” från Carly i Frankrike, sortimentet speciellt anpassat bl. a för värmepumpstillverka-re.

    Inverterstyrda kondensorag-gregat kan ge höga COP- vär-den och en intressant LCC- kal-kyl, inte minst i t ex storkök där belastningen varierar mycket över tiden.

    March 10-12 CholodExpo Rossija Russia www.globalfairs.de

    March 10-13 The Anuga FoodTech Germany www.anugafoodtec.com

    March 10-14 ISH Germany ish.messefrankfurt.com

    March 12-13 Danske Køledage Denmark www.dansk-koledag.dk

    April 28-30 The European Seafood Exposition Belgium www.euroseafood.com

    May 7-9 3rd IIR-Conference on Ammonia Refrigeration Technology Macedonia www.mf.ukim.edu.mk

    May 11-15 The Barcelona Food Technologies Spain www.bta-bcn.comRegistering is free of charge for conferences, meetings, fairs and other events of interest for the refrigeration industry. They will also be published at www.scanref.com.

    e v e n t s 2 0 0 9

  • [ScanRef . 1 . February 2009] 19

    RE

    PO

    RT

    S

    Svenska NIBE Industrier AB (NIBE) och japanska Mitsubishi Heavy Industries Ltd (MHI) i samarbete om värmepumpar

    " Reportage: Anders Hiorth

    NIBE med huvudkontor i Mar-karyd och MHI med huvud-kontor i Tokyo, har genom ett ganska unikt tekniksamarbete utvecklat en gemensam platt-form för en ny version av vär-mepumpar luft/vatten.

    Som vi tidigare har rapporte-rat i ScanRef och som statistik och prognoser visar, är detta den mest expansiva värme-pumpstypen för närvarande, såväl i Norden som i övriga Eu-ropa. Denna nya produkt kom-mer att marknadsföras under varumärket NIBE SPLIT.

    Annorlunda koncept „Värmepumpsmarknaden på kontinenten har p g a klimatet en annorlunda kravspecifi ka-tion. Där efterfrågas ofta att

    man kan producera såväl varm-vatten som värme, samt under sommaren även komfortkyla” berättar Kjell Ekermo, a! ärs-områdeschef på NIBE Villa-värme när ScanRef intervjuar honom.

    „Genom ett fullständigt öp-pet utvecklingsarbete företagen emellan har våra teknikteam kunnat dra nytta av bådas nyck-elkompetenser, vilket borgar för en produkt med höga prestan-da och hög kvalité. Dessa nya produkter kommer att säljas av båda företagens respektive va-rumärken, men i olika desig-nutföranden” fortsätter Kjell Ekermo.

    NIBE bedömer att denna produkt kan leda till såväl nya marknader som nya kunder, den kan t ex bli intressant för kylinstallatörer.

    Expansiv utlandsmarknad NIBE SPLIT ligger helt i linje med Europaparlamentets be-slut där bland mycket annat fastslås att energie! ektiviteten i Europa måste öka med minst

    20% och CO2-utsläppen mins-kas med minst 20% senast 2020.

    „Här kommer såväl mark-, sjö- som bergvärmepumpar men framförallt uteluftsvärme-pumpar att bli nyckelproduk-ter”, förtydligar Kjell Ekermo. „Enbart i Europa bedöms den årliga utbytesmarknaden för centralvärmeanläggningar till ungefär 5 miljoner enheter.

    Genom att NIBE SPLIT är installationsvänlig, har hög en-ergie! ektivitet och leder till kostnadsbesparingar för använ-daren, kommer detta att på-skynda överväxlingen från fos-sila bränslen till förnyelsebar energi. Detta kan ge a! ärsom-rådet NIBE Heating en kraftig internationell expansion” tilläg-ger Kjell Ekermo.

    Fördelad produktion Utomhusdelarna kommer att tillverkas på Mitsubishis fabri-ker, medan tankmodul och styr-system produceras genom NI-BE Heating i Markaryd. Tank-modulen är i mångt och mycket

    en redan existerande produkt hos NIBE Heating.

    NIBE SPLIT kommer att lanseras på ISH-mässan i Frankfurt under mars månad och försäljningen startar under första kvartalet 2009.

    I en tidigare artikel i Scan-Ref rapporterade vi om den första värmepumpen från MHI som installerades i Sverige, det var en luft/luft på 3 kW. Året var 1979 och den är fortfaran-de i full drift).

    NIBE och Mitsubishi Heavy i samarbete

    NIBE Industrier AB omsätter ca 5,6 miljarder SEK, har f n 5 500 anställda och är börs-noterade på Stockholms fond-börs sedan 1977.Mitsubishi Heavy Industri-es Ltd är ett gigantiskt, japanskt industriföretag med en omsättning på 3 203 mil-jarder Japanska Yen. MHI´s produktsortiment sträck-er sig från allt mellan skepps-varv och fl ygplan till värme-pumpar och elektronik.

    KølemidlerCO 2 HFC Ammoniak Glykol brine Jordvarme væske

    Brenntag Nordic introducerer fødevaregodkendt kølemiddel

    Brenntag N ordic is part of Brenntag, a leading globa l distributor of che m ica ls and raw m ateria ls

    Z i trec F C – nedtyndet efter frostsikringskrav – er e t mult ianvende ligt kø le m idde l baseret på monopro-pylenglycol, USP/E P kva lite t og indeholder kun F D A godkendte ingredienser.

    Z i trec F C er godkendt af N SF Internat iona l t il brug som kø le m idde l, hvor der er mulighed for kontakt m ed fødevarer.

    Z i trec F C er konform t il behovene fra N SF N onfood Compounds Registrat ion Progra m. D e er opført i N SF White Book List ing of N onfood Compounds, i kategori H T 1 - H eat Transfer F luids w ith incidenta l food con-tact (w w w.nsf.org - registreringsnr. 1 3 6 8 4 5).

    w w w .brenn t ag-nordic.co mm ain @brenn t ag-nordic.co m

    D an m ark + 4 5 4 3 2 9 2 8 0 0S v erig e + 4 6 3 3 2 3 1 8 8 0N org e + 4 7 6 9 1 0 2 5 0 0

    M ød os på D A N S K E K Ø L E D A G E 2 0 0 8Mød os påMød os på DANSKE KØLEDAGE DANSKE KØLEDAGE 20092009

  • 20 [ScanRef . 1 . February 2009]

    RE

    PO

    RT

    S

    Djupfrysta konsument-förpackade livsmedel må ha varit en amerikansk uppfi nning, men Sverige är världsledande när det gäller utvecklingen av infrysningsteknik.

    Det säger Göran Löndahl til Djupfrysningsbyråns nyhets-brev Kristallklart december 2008.

    Göran Löndahl kom in i djupfrystbranschen redan som ung student 1958. Då hade de två första moderna fryshusen – ett i Stockholm och ett i Hel-singborg – just etablerats i Sve-rige.

    „Det fanns visserligen några fryshus dessförinnan på olika platser i landet, men de var orationella genom att de var byggda i fl era våningar och fungerade mest som bered-skaps- och överskottslager för grossister och producenter”, säger han.

    Göran Löndahl minns ock-så frystågen, som var en inno-vation i samarbete med SJ.

    „De här tågen gick bara på

    sommaren och var försedda med frystunnlar”.

    Syftet med innovationen var att frysa in bär till saftindustrin från bärplockare runtom i lan-det.

    Projektet var dock inte sär-skilt lönsamt och bärtågen för-svann efter två säsonger”.

    Infrysning skedde i enkla frystunnlar som användes för alla typer av produkter. Att hantera stora mängder sä-songsprodukter, till exempel ärtor, på detta sätt var mycket arbetskrävande.

    Dåvarande Helsingborgs Fryshus, sedermera Frigoscan-dia, fi ck i början av 60-talet i uppdrag att bygga en speciell frysare för dessa produkter. Problemet var dock att frysen bara användes sex-sju veckor om året, vilket inte var särskilt rationellt.

    „Frigoscandia insåg det sto-ra behovet av snabb och eko-nomiskt e! ektiv infrysning av ett brett sortiment produkter vilket ledde till utveckling av en frysare baserad på fl uidise-ringsteknik, FloFreeze. En ut-

    rustning som kom att revolu-tionera frystekniken då pro-dukterna frystes individuellt. Individuell Quick Freezing IQF, blev ett begrepp över he-la världen.

    Tekniken innebär också en rationellare hantering efter in-frysning då produkterna en-kelt kan bulklagras och -trans-porteras för senare förpack-ning till konsument/storhus-håll, allt efter marknadens be-hov.

    Nästa steg i frysarutveck-lingen var spiralfrysaren. Den-na typ, GyroFreeze, användes för bl a hamburgare, som var på väg att bli en allt större pro-dukt, men kunde också använ-das för andra produkter, oför-packade som förpackade.

    „Även denna frysare utveck-lades av Frigoscandia liksom pelletfrysaren, PelloFreeze, som kom en bit in på 1970-ta-let och som användes för in-frysning av produkter som spe-nat, såser och juicer m m i små pellets. Dessförinnan hade ett antal andra system utvecklats, bl a speciell utrustning för in-

    frysning av hela kartonger, glasshärdare m.fl .” berättar Göran Löndahl.

    Den senaste stora innovatio-nen inom frystekniken är im-pingementfrysaren för extremt snabb infrysning.

    ”Den tekniken har innebu-rit att helt nya applikations-områden har kunnat utveck-las. Den första frysen av denna typ kom ut på marknaden för ca 10 år sedan. Den extremt snabba infrysningen gör att frysarna också kan användas för kylda produkter, t ex skivad skinka som ytfryses före skiv-ningen”.

    Göran Löndahl menar att Sverige historiskt sett har varit och är världsledande inom frystekniken på livsmedelsom-rådet.

    „Inget annat land, möjligen med undantag för Norge, har heller utbildat så många frys-tekniker som Sverige”, säger Göran Löndahl till Kristall-klart.

    Den mest engagerede skare af energiinteresse-rede ingeniørstuderende fra hele Europa har gennem en uge suget ny viden til sig på Aalborg Universitet.

    Forelæsninger, virksomhedsbe-søg, idéudvikling og ikke mindst networking har åbnet nye døre på tværs af grænser.

    Det er Aalborg-afdelingen af den internationale studenteror-ganisation BEST (Board of European Students of Techno-logy), der har sørget for at sam-le energiinteresserede ingeniør-studerende fra 19 europæiske lande til det ugelange forløb.

    Blandt 120 interesserede an-søgere blev 25 personer på bag-grund af deres engagement ud-valgt, og de unge ingeniører

    Energiuge gav studerende nye netværk

    Sverige världsledande inom frystekniken

    har blandt andet stillet sig selv og hinanden en opgave om at udvikle idéer til, hvordan man kan nedbringe vandforbruget i bygningskomplekser.

    „Vi har i løbet af ugen ople-vet et helt enormt engagement fra de studerende, og noget af det, jeg især har bidt mærke i, er hvor mange spørgsmål, der bliver stillet til vores forelæsere. Mange af vores gæster er be-gejstrede for undervisningsfor-men her i Aalborg, hvor det er helt naturligt for den studeren-de at være i dialog med profes-soren”, fortæller den lokale BEST-formand Jacob Veed-fald, der også har overværet fl e-re af deltagerne undersøge mu-lighederne for at gøre deres ud-dannelse færdig på AAU.

    Den internationale temauge byder på emner som energi, energitransport, eltransmission, termisk energi, vindenergi og kraftvarme, og ud over de fagli-ge forelæsninger har den også stået på idéudvikling under le-

    delse af kreativitetskonsulenter fra ILOSI samt fl ere virksom-hedsbesøg og ekskursioner.

    De studerende har således besøgt både AET-Biomass, Vestas og Vattenfall, og mødt tolv repræsentanter fra blandt andet Rambøll, DONG Ener-gy, Siemens Power Electronics, Energistyrelsen og Energinet.dk.

    Studenterorganisationens med lemmer lægger mange ti-mers arbejde i tilrettelæggelse, virksomhedskontakt og prakti-ske forhold under temaugen, der er støttet af Aalborg Uni-versitet, både med økonomiske midler, med lokalefaciliteter og med undervisere fra Institut for Samfundsudvikling & Planlæg-ning og Institut for Energitek-nik.

  • Fokus på sikkerhed, energi og miljø har aldrig været større i den danske kølebranche.

    Aldrig har kølebranchen oplevet så mange regler, reguleringer og krav - nationalt såvel som internationalt - som nu. Kølebranchen lever i en brydningstid, der ikke er set mage. Producenter, virksomheder og kølefi rmaer må hele tiden agere for at leve op til de stadig stigende krav på et område, som i forvejen er stærkt reguleret.Desværre oplever vi en manglende koordinering fra myndighedernes side af de mange regelsæt.Kølebranchen er i dag underlagt regler udstedt af Beskæftigelsesministeriet (Arbejdstilsynet), Miljøministeriet (Miljøstyrelsen), Klima- og Energiministeriet (Energistyrelsen) og Forsvarsministeriet (Beredskabsstyrelsen) for at nævne de største ministerielle aktører. Dertil kommer de internationale reguleringer i EU-regi.

    Som branche er det forvirrende og frustrerende at skulle leve op til en masse regler, som burde være samlet og koordineret ét sted - af én myndighed. Med andre ord: Et land - og et sæt regler, der respekteres af alle ministerier. Samtidig bliver virksomhederne mødt med nye krav om bl.a. efteruddannelsen af medarbejdere. I

    forvejen er den danske kølebranche - i kraft af den stærke regulering inden for brug af de drivhusskadelige og ozonlagsnedbrydende kølemidler - førende i forhold til anvendelsen af de naturlige kølemidler.

    Alligevel ser branchen med en vis skepsis på de fremtidige reguleringer i en tid med nye politiske tiltag på miljøområdet. Det gælder både nationalt og internationalt.

    Vi har imidlertid brug for at få ro og klarhed, så producenter, virksomheder og kølefi rmaer i større omfang kan planlægge udviklingen af virksomheden og medarbejderne.

    I andre lande eksisterer ikke samme uklarheder myndighederne imellem. Der er det overblik, vi savner i Danmark: Et regelsæt - et ministerium.

    Velkommen til Danske Køledage 2009

    Lau Vørs, formand for Dansk Køledag f.m.b.a.

    Registrering: Torsdag den 12. marts kl. 8.30-18.30 Fredag den 13. marts kl. 8.30-15.00

    Udstilling: Torsdag den 12. marts kl. 8.30-18.45 Fredag den 13. marts kl. 8.30-15.30

    Konference: Torsdag den 12. marts kl. 8.30-18.45 Fredag den 13. marts kl. 8.30-13.00

    Ikke konferencedeltagere (gratis adgang): Torsdag den 12. marts kl. 10.00-18.45 Fredag den 13. marts kl. 09.00-15.30

    Sted: Odense Congress Center, Ørbækvej 350, 5220 Odense SØ.

    Tilmelding: Senest den 6. marts, herefter er tilmeldingen bindende. Virksomheden kan frit vælge at sende en anden deltager.

    Hotel: Hotelreservation kan, i forbindelse med deltagelse i konferencen, foretages hos Dansk Køledag f.m.b.a. Der afregnes direkte med hotellet.

    Pris: Deltagelse begge dage pr. person kr. 2.950,- Deltagelse den 12. marts pr. person kr. 2.125,- Deltagelse den 13. marts pr. person kr. 1.150,- Studerende: kr. 350,- pr. dag. Lærlinge: kr. 350,- pr. dag. Pensionister: kr. 350,- pr. dag.

    Prisenomfatter: Adgang til foredrag, udstilling, stående buffet og 1 stk. kompendium i papirformat. Såfremt det ikke er muligt at deltage på Danske Køledag 2009, kan kompendium bestilles hos Dansk Køledag f.m.b.a. pris kr. 1.200,-

    Aftenarran-gement: Torsdag den 12. marts kl. 20.00-00.30 kr. 750,- ekskl. moms. Prisen er for middag inkl. drikkevarer og underholdning.

    Betaling: Via indbetalingskort.

    Ved force majeure forbeholder Dansk Køledag sig retten til at fl ytte arrangementet med hensyn til tid og sted, subsidiært afl yse.

    Praktiske oplysninger

  • N O R D E N S S T Ø R S T E K Ø L E K O N F E R E N C E2

    Program torsdag 12. marts 8.30-09.30 Ankomst & registrering - Kaffe i udstillingen i Hal B

    9.30-09.45 Velkomst - Lisbeth Groth Haastrup, direktør for Dansk Køledag f.m.b.a., og Lau Vørs, formand for Dansk Køledag f.m.b.a. - Lokale Jylland

    9.45-10.15 Hovedtale - Steen Gade (SF), Formand for Folketingets Miljø- og Planlægningsudvalg - Lokale Jylland

    10.15-10.45 Hovedtale - Kjeld Stærk, President, Danfoss Refrigeration & Air Conditioning Division

    10.45-11.15 Klimaændringer – Vildt vejr og orkaner i baghaven - Jesper Theilgaard - Lokale Jylland

    11.15-11.30 Uddeling af Dansk Køledags Ærespris - Lokale Jylland

    11.30-12.30 Kaffepause i udstillingen i Hal B

    Tema: Fra rådgivning til afl evering

    Lokale Sjælland

    Målgruppe: InstallatørerLokale Jylland

    Målgruppe: Forskning/Research

    Lokale Fyn

    12.30-13.15 Test af køleanlæg

    Laurids Finnemann, ALECTIA A/S

    Olie til naturlige kølemidler Modellering af skævfordeling i fordampere med modelica

    Martin Kærn, Danfoss

    13.15-15.15 Frokost i udstillingen i Hal B

    15.15-15.40

    15.45-16.30

    Støj fra køleanlæg

    Peder Lykkeberg, Noise Control Consultant

    Kravspecifi kation kontra afl everinger

    Christian Hansen, Grontmij | Carl Bro

    Transkritisk kontra subkritisk – valg af CO2-køleanlæg iDanmark

    Kenneth Madsen, DanfossChristian Heerup, Teknologisk Institut

    Minivarmepumpe (EFP projekt):

    Per Henrik Pedersen, Marcin Andreasen,Klaus Frederiksen, Teknologisk Institut

    Electricity surplus and Application of Heat pumps for Energy System Control

    Brian Elmegaard, DTU

    16.30-17.15 Kaffepause i udstillingen i Hal B

    17.15-17.45 Driftsomkostninger kontra investeringer

    Mikael Fænø Bastholm,ALECTIA A/S

    Fokuspunkter for komponentvalg til kulbrinteanlæg

    Niels Vestergaard, Danfoss

    Detektering af fouling i pladevarmevekslere

    Ebbe Nørgaard, Teknologisk Institut

    17.45-18.45 Udstilling

    17.50-18.00 Afgørelse af designkonkurrence

    20.00-00.30 Aftenarrangement med middag

  • 3N O R D E N S S T Ø R S T E K Ø L E K O N F E R E N C E

    8.00-09.00 Ankomst & registrering - Kaffe i udstillingen i Hal B

    9.00-09.35 Kick-off - Lasse Rimmer

    Tema: KølemidlerLokale Sjælland

    Tema: Ventilation og kølingLokale Jylland

    Short Course: Dimensionering af sekundær vandkreds - Lokale Fyn

    9.40-10.15 Ændringer i EN 378 -2008

    Niels Vestergaard, formand for standardiseringsudvalget S251

    Energimærkning af klimaanlæg

    Mogens Palm Hansen, Dansk Varefakta Nævn

    Den nemme start på det vandbårne system

    Fokuspunkter:Tryktab, Rør, Ventiler, Pumper

    10.15-11.00 Kaffepause i udstillingen i Hal B

    11.00-11.45

    11.45-12.20

    12.25-13.00

    Hvor kan man anvende NH3 og hvor små kan anlæggene blive?

    Alexander Cohr Pachai, Johnson Controls

    Valg af brinetype i sekundærkreds

    Morten Juel Skovrup, IPU

    Praktisk håndtering og vedligehold af kølevæsker

    Kaj Foldal, L. C. Glad Company A/S

    Krav til lovpligtigt eftersyn på ventilation i forbindelse med køleanlæg

    Mogens Johansson, Dansk Energi Analyse A/S

    Regler og guidelines for ventilationsanlæg

    Per Knudsen, EXHAUSTO

    Varmegenvinding på ventilationsanlæg

    Michael Ammitzbøll, Nilan