Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering...

5
Russellstoll J-Line Interconnection Systems - Ordering Information 30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC Load Breaking Receptacles, Plugs, Connectors & Inlets Connectors Receptacles ^ * DV JCF323H _ JCF333F JCF334H JCF344F JCS323H JCS333F JCS334H JCS344F JCF623H JCF633F JCF634H JCF644F JCS623H JCS633F JCS634H JCS644F JCF1023H JCF1033F JCF1034H JCF1044F JCS1023H JCS1033F JCS1034H JCS1044F JCF2023H JCF2033F JCF2034H JCF2044F JCS2023H JCS2033F JCS2034H JCS2044F 'ii Panel Mount * O Y JRFX323H _ JRFX333F JRFX334H JRFX344F JRSX323H JRSX333F JRSX334H JRSX344F JRFX623H JRFX633F JRFX634H JRFX644F JRSX623H JRSX633F JRSX634H JRSX644F JRFX1023H JRFX1033F JRFX1034H JRFX1044F JRSX1023H JRSX1033F JRSX1034H JRSX1044F JRFX2023H JRFX2033F JRFX2034H JRFX2044F JRSX2023H JRSX2033F JRSX2034H JRSX2044F Basic Receptacle * a v JRF323H _ JRF333F JRF334H JRF344F JRS323H JRS333F JRS334H JRS344F JRF623H JRF633F JRF634H JRF644F JRS623H JRS633F JRS634H JRS644F JRF1023H JRF1033F JRF1034H JRF1044F JRS1023H JRS1033F JRS1034H JRS1044F JRF2023H JRF2033F JRF2034H JRF2044F JRS2023H JRS2033F JRS2034H JRS2044F Standard Series* * a T JRFA323H _ JRFA333F JRFA334H JRFA344F JRSA323H JRSA333F JRSA334H JRSA344F JRFA623H JRFA633F JRFA634H JRFA644F JRSA623H JRSA633F JRSA634H JRSA644F JRFA1023H JRFA1033F JRFA1034H JRFA1044F JRSA1023H JRSA1033F JRSA1034H JRSA1044F JRFA2023H JRFA2033F JRFA2034H JRFA2044F JRSA2023H JRSA2033F JRSA2034H JRSA2044F Conduit Size: (Using JPA_ Series Conduit Adapters) Current Rating 30 60 100 200 Std. Size 1" 1'/2" 2" 3" Max. Size 1 1 /4" 1 1 /2" 2" 3" * Smaller NPT openings available on request. Cable Conduit Adapters: see page 42. Conduit Entry Location: Standard Series B Std. B Std. A- kc A- kc 30 & 60 Amp 100 & 200 Amp ThomasiBetts © 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COm 37

Transcript of Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering...

Page 1: Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering Information 30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC Load Breaking

RussellstollJ-Line Interconnection Systems - Ordering Information30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDCLoad Breaking Receptacles, Plugs, Connectors & Inlets

Connectors Receptacles

* DVJCF323H _JCF333FJCF334HJCF344F

JCS323HJCS333FJCS334HJCS344F

JCF623HJCF633FJCF634HJCF644F

JCS623HJCS633FJCS634HJCS644F

JCF1023HJCF1033FJCF1034HJCF1044F

JCS1023HJCS1033FJCS1034HJCS1044F

JCF2023HJCF2033FJCF2034HJCF2044F

JCS2023HJCS2033FJCS2034HJCS2044F

'iiPanel Mount* O Y

JRFX323H _JRFX333FJRFX334HJRFX344F

JRSX323HJRSX333FJRSX334HJRSX344F

JRFX623HJRFX633FJRFX634HJRFX644F

JRSX623HJRSX633FJRSX634HJRSX644F

JRFX1023HJRFX1033FJRFX1034HJRFX1044F

JRSX1023HJRSX1033FJRSX1034HJRSX1044F

JRFX2023HJRFX2033FJRFX2034HJRFX2044F

JRSX2023HJRSX2033FJRSX2034HJRSX2044F

Basic Receptacle* a v

JRF323H _JRF333FJRF334HJRF344F

JRS323HJRS333FJRS334HJRS344F

JRF623HJRF633FJRF634HJRF644F

JRS623HJRS633FJRS634HJRS644F

JRF1023HJRF1033FJRF1034HJRF1044F

JRS1023HJRS1033FJRS1034HJRS1044F

JRF2023HJRF2033FJRF2034HJRF2044F

JRS2023HJRS2033FJRS2034HJRS2044F

Standard Series** a T

JRFA323H _JRFA333FJRFA334HJRFA344F

JRSA323HJRSA333FJRSA334HJRSA344F

JRFA623HJRFA633FJRFA634HJRFA644F

JRSA623HJRSA633FJRSA634HJRSA644F

JRFA1023HJRFA1033FJRFA1034HJRFA1044F

JRSA1023HJRSA1033FJRSA1034HJRSA1044F

JRFA2023HJRFA2033FJRFA2034HJRFA2044F

JRSA2023HJRSA2033FJRSA2034HJRSA2044F

Conduit Size: (Using JPA_ Series Conduit Adapters)

Current Rating3060

1 0 0200

Std. Size1"

1'/2"

2"3"

Max. Size11/4"

11 /2"

2"3"

* Smaller NPT openings available on request.Cable Conduit Adapters: see page 42.

Conduit Entry Location: Standard SeriesB Std. B Std.

A- kc A- kc

30 & 60 Amp 100 & 200 Amp

ThomasiBetts© 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COm 37

Page 2: Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering Information 30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC Load Breaking

RussellstollJ-Line Interconnection Systems30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDCLoad Breaking Receptacles, Plugs, Connectors & Inlets

Design FeaturesRussellstoll® J-Line Load Breaking Plugs, Connectors and Receptacles

1. Circuit interrupting rated safety.2. Cast aluminum, corrosion resistant copper free

alloy housings and enclosures provide light weightand maximum corrosion resistance, along withelectrostatic epoxy powder coat finish.

3. Quick conversion between weathertight flap coverand watertight screw cap assemblies. Basicreceptacle housing accommodates both covers .and is the basic component of all complete units.All watertight configured plugs may be usedinterchangeably.

4. Two grounding arrangements(Style No. 1 and Style No. 2).

5. Four Complete J-Lines30, 60, 100 and 200 Amps, 600 Volts, A.C. 250Volts, D.C. (plus 150A/270A specials)

6. Flap cover can be rotated and locked in anyconvenient position.

7. Pressure type solderless wiring terminals.8. Silver plated contacts.9. One-piece interior assemblies.

Interchangeable from regular to reverse service inthe field with a screwdriver.

10. Wiring spaceAmple for maximum requirements.

11. Cable ClampsAdjustable, for maximum range of cable size. Oilresistant neoprene strain-relief bushingcompresses around cable tightly, prevents entry ofdust and moisture.

12. PolarizationProvides positive non-interchangeability fordifferent electrical systems.

13. Reversed contacts flexibility male-female reversedinstallation within any housing.

ThomasiBetts© 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COITI 31

Page 3: Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering Information 30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC Load Breaking

RussellstollJ-Line Interconnection Systems30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDCLoad Breaking Receptacles, Plugs, Connectors & Inlets

Reversed Contacts ServiceFor all Weathertight and Watertight types

All J-Line plugs, receptacles and connectors can befurnished for Reverse Service - male (plug) interiors in thereceptacles and female (receptacle) interiors in the plugs.When ordering reverse service add a final suffix "R" to thecomplete catalog number. Price on application.Example: JRFA334HR

J-Line receptacle and plug interior assemblies of the sameamperage may be quickly interchanged from regular toreverse service (or vice versa) in the field. A screwdriver isthe only tool required.

Example: Panel mounted low profile receptacles with maleinteriors act as Male Inlets in remote equipment;receive power from "Female Plugs". (Cup cap alsorecommended).

Regular ServiceInterior assemblies placed in normalstandard positions - female interiorassembly is positioned in thereceptacle housing and the maleinterior assembly is positionedin the plug housing.

Reverse ServiceNote the complete interior assemblies have nowbeen interchanged so that the male (plug) interiorassembly is positioned in the receptacle housingand the female (receptacle) interior assembly ispositioned in the plug housing.

ThomasiBetts© 2001 Thomas & Betts Corporation. Specifications are subject to change without notice. WWW.tnb.COIT) 33

Page 4: Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering Information 30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC Load Breaking

RussellstollJ-Line Interconnection Systems30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDCLoad Breaking Receptacles, Plugs, Connectors & Inlets

Grounding DataEffective grounding of portable electric equipment isnecessary to protect operators from electric shock. TheNational Electrical Code requires that in most casesexposed non-current-carrying metal parts of portableequipment shall be grounded if operated at more than 150volts to ground. Grounding must be used in other thanresidential occupancies when used in damp or wet

locations, or by persons standing on the ground or on metalfloors or working inside of metal tanks or. boilers, exceptwhere supplied through an insulating transformer withungrounded secondary of not over 50 volts. Plugs andreceptacles provide for grounding of portable equipmentin either of two ways:

Style 1 - Typical 3P3W Plug & Receptacle

Portable cord3 conductors + G

Equipment groundconnected toplug shell

STYLE 14P4W (or 3P3W)Through Metal Housings of Plug and ReceptacleIn this system shown above, the equipment groundingconductor in the flexible cable is electrically connecteddirectly to the plug or cable connector housing by a suitableterminal. The receptacle is grounded by being part of agrounded conduit system.When inserted, the plug housing makes contact with thegrounded receptacle or connector housing by means of thereceptacle ground spring before the current-carryingcontacts engage. On withdrawal, it remains in contact untilafter the current-carrying contacts disengage.

Style 2 - Typical 3P4W Plug & Receptacle.

Equipment groundconnected to extrapole and plug shel

Factory installedjumper

STYLE 23P4W (or 2P3W)Through a Separate Grounding Pole in Plug andReceptacleIn this system shown above, the equipment groundingconductor in the flexible cable is electrically connected to theequipment grounding pole in the plug or cable connectorinterior. The grounding pole of the receptacle interior is elec-trically connected by a spring strap jumper to the receptaclehousing which itself is grounded by being part of the groundspring of the receptacle or connector housing as described insystem number one.The grounding contact in a type 2 receptacle is longer thanthe current-carrying contacts so that the ground connectionmakes first and breaks last.

Corrosive Locations: The National Electrical Code requiresthat under conditions favorable to corrosion, the groundingconductor for enclosures and equipment be of copper orother corrosion-resistant material. In alternating currentsystems, this necessitates running another conductor backto the common grounding electrode. This may be run

through the conduit containing the circuit conductors. At thereceptacle, this grounding conductor should be connectedto the extra (grounding) pole by the pressure connectorprovided for that purpose. Where such an extra groundingconductor is required, Style 2 receptacles should be used.

ThomasiBetts34 © 2001 Thomas & Betts Corporation. Specifications are subject to change without notice. WWW.tnb.COm

Page 5: Russellstoll - WESCO International · Russellstoll J-Line Interconnection Systems - Ordering Information 30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC Load Breaking

RussellstollJ-Line Interconnection Systems - Ordering Information30-270 Amp, (30, 60, 100 and 200 Amp Load Breakingit>u ana z/u Amp bpeciai bervice) Maximum t>uu VAO/^SU vuo - ^^^^••TTff'I ^^^^HReceptacles, Plugs, Connectors & Inlets ^^^^^^^Jl ^^^^^g

=or any J-Line catalog numbers not shown here, check page 35 for "Series"information.cor special polarizations (suffixes) contact Tech Support.

Max. 600VAC / 250VDCCurrent Rating

30 Amp

60 Amp

100 Amp(150 Amp)** lij

200 Amp(270 Amp)**

. - - '- . ' : :,;-.;;.-•...-'•.-:.; ::',

Weathertight / Watertight

Weathertight(Spring Hinged Flap Cover)

Watertight(Screw Cover)

Weathertight(Spring Hinged Flap Cover)

Watertight(Screw Cover)

Weathertight(Spring Hinged Flap Cover)

Watertight(Screw Cover)

Weathertight(Spring Hinged Flap Cover)

Watertight(Screw Cover)

Configuration

: 2P3W: 3P3W*

3P4W4P4W*

; : :: 2P3W'•::•': "-•':< 3P3W*

3P4W4P4W*

2P3WijMX 3P3W* • ' . ';7"': ":;:'"•. 3P4W -,\i ;;.;•;,.;.;•;•;.:.;

4P4W*2P3W

mi,:';^. 3P3W*;F" • ' . • : " • 3R4W ...;-..;•=•;--•-;!

' 4P4W* ; ;'::;'i?'V?;'K;

2P3W,,:;.;. iffi^-a;, 3P3W*;-h, ••;«*}=« 3p4w

4P4W*2P3W3P3W*3P4W4P4W*2P3WSPSW* .' -;..!.:": •-:?: v3P4W4P4W*2P3W3P3W*3P4W4P4W*

(All plugs come withwatertight screw collar)

OTJPS323H _JPS333FJPS334HJPS344FJPS323HJPS333FJPS334HJPS344FJPS623HJPS633FJPS634HJPS644FJPS623HJPS633FJPS634HJPS644FJPS1023HJPS1033FJPS1034HJPS1044FJPS1023HJPS1033FJPS1034HJPS1044FJPS2023HJPS2033FJPS2034HJPS2044FJPS2023HJPS2033FJPS2034HJPS2044F

i

<

* Housing Ground Only (Style 1 Grounding) see page 34.+ Shown with 20° angle adapter. Can be furnished with 45° angle at same price. When ordering add

suffix -45 to catalog number.** Special rated devices (not shown). Consult customer service for details.Note: To order Reverse Service add a final suffix "R" to catalog number. Examples: JRFA334HR — a

receptacle housing with male interior.O Polarization index (std. shown) Consult tech support for more.4 Flap Cover "F" noted. Screw Cover "S" also availableT For Reversed Contacts, use "R" suffix to any catalog number.

Std. Cable BushingCurrent Rating

3060100200

Bushing I.D.7/8"

1W11/2"

2"

Max. AWG Size

#6 - 7 strand or #8 flexible#4 - 7 strand or flexible#0 -19 strand or#1 flexible#4/0 -19 strand or flexible

(see page 41 for other bushings)<

ThomasiBetts36 © 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COrn