RPL: RDS 708 Vintage B, Roof Mounted Air Handler...Replacement Parts List No. 047652600 Revision G...
Transcript of RPL: RDS 708 Vintage B, Roof Mounted Air Handler...Replacement Parts List No. 047652600 Revision G...
Replacement Parts List No. 047652600Revision G 07/2019
DaikinMcQuay
Roofpak™Applied Rooftop Air Handler
RDSSize 708
Vintage B
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 2
Contents
Parts List Revision History ................................................................................................................................................ 4Unit Model & Serial Number Nomenclature ..................................................................................................................... 5Unit Model Number- Complete ...................................................................................................................................... 6- 9 Typical Unit Layout Diagrams ......................................................................................................................................... 10 Electrical Legend .............................................................................................................................................................. 11 Section A- Return Air Section Notes............................................................................................................................................................................ 12 0- 30% Outside Air Damper with Hood: Code 18= A .................................................................................................. 13 0- 100% Economizer with Hoods & Barometric Exhaust Damper: Code 18= B .......................................................... 14 0- 100% Outside Air Damper with Hood: Code 15= K (After 3/04) .............................................................................. 15 100% Hood w/o Damper: Code 15= J ......................................................................................................................... 15 0- 100% Outside Air Damper Mixing Box with Hood: Code 18= M ............................................................................. 16 Return Fan Dampers ................................................................................................................................................... 17 Return Fan Assemblies 15" x 15" Forward Curved Fan w/o Variable Inlet Vanes ................................................................................... 18, 19 15" x 15" Forward Curved Fans w/ Variable Inlet Vanes .................................................................................. 20, 21 16" Airfoil Fans w/o Variable Inlet Vanes ........................................................................................................... 22, 23 16" Airfoil Fans w/ Variable Inlet Vanes ............................................................................................................. 24- 26 Return Air Fan Mounting 15" x 15" Forward Curved Fan ................................................................................................................................ 27 15" x 15" Forward Curved Fan w/ Seismic Mounting .............................................................................................. 28 16" Airfoil Fan .......................................................................................................................................................... 29 16" Airfoil Fan w/ Seismic Mounting ........................................................................................................................ 30 Return Air Fan Motors ................................................................................................................................................. 31 Miscellaneous Electrical Components: LT11, S11, REC11 .......................................................................................... 32Section B- Economizer Damper Section Notes ........................................................................................................................................................................... 33 Economizer Dampers: Code 18= B ............................................................................................................................. 34Section C- Filter/Final Filter Section Notes ........................................................................................................................................................................... 35 Filter Section Filters 1996 & Before ......................................................................................................................................... 36, 37 Filters 1999 & Later .......................................................................................................................................... 38- 40Section D- Coil Section Notes ........................................................................................................................................................................... 41 Contractor Coil Code Strings ....................................................................................................................................... 42 Drain Pans & Piping Vestibule ..................................................................................................................................... 43 Face & Bypass Dampers ............................................................................................................................................. 44Section E- Supply Fan Section Notes ........................................................................................................................................................................... 45 Supply Fan Dampers ................................................................................................................................................... 46 Fan Assemblies 15" Forward Curved Fans w/o Inlet Vanes ........................................................................................................ 47, 48 15" x 15" Forward Curved Fan w/ Inlet Vanes .................................................................................................. 49, 50 16" Airfoil Fans w/o Variable Inlet Vanes ........................................................................................................... 51, 52 16" Airfoil Fans w/ Variable Inlet Vanes ............................................................................................................. 53- 55 Supply Air Fan Mounting Diagrams ................................................................................................................................................................. 56 15" Forward Curved Fans- Components .......................................................................................................... 57, 58 16" Airfoil Fan- Components ............................................................................................................................. 59, 60 Additional Seismic Restraint Components .............................................................................................................. 61 Supply Air Fan Motors.................................................................................................................................................. 62 Miscellaneous Electrical Components- LT10, S10, REC10 ......................................................................................... 63Section F- Discharge Plenum Section Notes ........................................................................................................................................................................... 64
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 3
Contents, Continued
Section G- Power Panel/Main Control Box Notes ........................................................................................................................................................................... 65 Power Panel: Code 06= A, E Diagram .................................................................................................................................................................. 66 Common Components ............................................................................................................................................ 67 Fan Motor Contactors, Overloads & Fusing Components ................................................................................ 68- 71 Power Panel: Code 06= B, F Diagrams ................................................................................................................................................................. 72 Common Components ...................................................................................................................................... 73, 74 Disconnect Switch DS1: Code 08= YY ................................................................................................................... 75 Circuit Breaker CB1: Code 08= *A ......................................................................................................................... 76 Supply MMP10 & M10 Fan Contactor & Return MMP20 & M20 Fan Contactor ............................................... 77- 81 Power Panel: Code 06= C, G Diagrams ................................................................................................................................................................. 82 Control Box Component Label Diagram ................................................................................................................. 83 Common Components ...................................................................................................................................... 84, 85 Disconnect Switch DS1: Code 08= YY AND Code 23= A, E .................................................................................. 86 Circuit Breaker CB1: Code 08= *A ......................................................................................................................... 87 Supply MMP10 & M10 Fan Contactor & Return MMP20 & M20 Fan Contactor ............................................... 88- 90 Inverters (VFD/AFD) ................................................................................................................................................... 91Section H- Miscellaneous Cabinet Components Notes ........................................................................................................................................................................... 92 Door Latches ............................................................................................................................................................... 92 Door Hinge .................................................................................................................................................................. 92 Door Holding Rod ........................................................................................................................................................ 92
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 4
Rev. Date Description New 4/89 4/89 is the date of online scanned RPL. Unknown number of previous revisions from 1984 original, consider as new. A 8/11 Released updated version in current software format. B 12/11 Page 30, 60: Corrected voltage code in table from Code "03" to "04". Page 43: Rewrote notes. C 6/12 Cover, Rev. Page: Updated to Daikin McQuay logo format. Various: Changed "McQuay Parts" to "Daikin McQuay". Page 88: P/N 098861454 is ONLY 5HP 460V. Deleted invalid table information and re-arranged p/n order. Added footnote #3. D 2/14 Cover, Rev. pg.: Updated to Daikin Applied logo format. Various: Changed “McQuay” and “Daikin McQuay” to “Daikin Applied”. Page 6: Added footnote #1. Page 7: Deleted unused Code 14 option "T". Page 8: Updated Code 24. Page 12, 32, 34, 39, 43, 62, 63: Rewrote Notes. Added unit dwg. Page 13, 31: Added dwg. header. Page 17- 23, 25, 45- 51: Rewrote footnotes. Page 22, 25, 50, 53: Changed Ref # 2 description from "Housing Assy." to "Wheel/Housing Assy." Rewrote footnote # 2. Page 33: Changed Ref. # 21 p/ns from "045857701" to "045657701". Page 41, 42: Rewrote Coil Bub. header description. Page 66- 69: Removed OL & OL Heater p/ns. Rewrote footnotes. Page 72: Rewrote footnote and corrected footnote notation. Page 77: Updated dwg. Added in Bub # 3A. Rewrote footnote #2. Page 78: Added Ref. # 3A to table. Deleted N/S footnote references. Page 88: Rewrote footnote # 2. Page 89: Reorganized and updated entire page. Rewrote Notes. Updated TOC. E 10/16 Cover: Updated to Daikin Legacy format. Page 11: Added footnote # 1 & footnote notation. Page 12, 39, 43: Rewrote Notes. Page 14, 15: Rewrote footnote # 1. F 03/18 Page 12, 43: Rewrote Notes. Page 17, 19, 21, 23, 45, 47, 49, 51: Rewrote footnote # 1. Page 18, 20, 22, 25, 46, 48, 50, 53: Rewrote note # 1. G 07/19 Various: Changed "Blank Section" to "Blank/Empty Section". Rewrote footnote re. Act. field supplied, Drive Components ID procedure, & contacting DAA. Rewrote Pwr. Pnl. pg. headers, deleted footnotes as needed, & updated the TOC. Changed "VFD" to "VFD/AFD". Page 6- 9, 11: Misc. updates/corrections/additions. Page 10: Updated the unit dwg. & section legend. Rewrote footnote # 1. Page 12, 43, 63 (OLD) 12, 44, 64 (NEW): Rewrote Notes. Page 14 (NEW): Added pg. for Barometric Econo. Hood info. Repaginated the form & updated the TOC. Page 15: Rewrote/added footnotes. Page 20, 25, 48, 53 (OLD) 21, 26, 49, 54 (NEW): Added footnote re. VIV obsolescence. Page 23, 24, 51, 52 (OLD) 24, 25, 52, 53 (NEW): Updated dwg. Page 31, 61 (OLD) 32, 62 (NEW): Added 7/13 & Later Light Fixture info. Changed "Lamp" to "Light". Page 33 (OLD) 34 (NEW): Added footnote # 2. Page 40 (NEW): Added pg. for Final Fitlers. Rewrote pg. header. Repaginated the form & updated the TOC. Page 39 (OLD) 41 (NEW): Added Coil Section dwg. Page 48 (OLD) 50 (NEW): Rewrote/deleted footnotes. Page 64 (OLD) 66 (NEW): Rewrote footnote # 1. Page 65 (OLD) 67 (NEW): Misc. updates/corrections/additions. Rewrote footnotes. Page 66- 68 (OLD) 68- 70 (NEW): Misc. updates/corrections. Page 71 (OLD) 73 (NEW): Misc. updates/additions/corrections. Added mtr. coding. Page 72, 73 (OLD) 75, 76 (NEW): Rewrote pg. headers & updated the TOC. Misc. corrections. Updated the dwgs. Rewrote footnotes as needed. Page 77, 85 (NEW): Added pg. for additional Common Comps. Updated p/ns. Page 74- 78 (OLD) 77- 81 (NEW): Misc. updates/corrections/additions. Rewrote/added footnotes as needed. Page 83, 84 (OLD) 88, 89 (NEW): Deleted pg. Repaginated the form & updated the TOC. Page 87 (NEW): Added pg. for CB1 comps. Repaginated the form & updated the TOC. Page 88 (OLD) 91 (NEW): Deleted Reliance table. Updated ABB p/ns. Added dwgs. Rewrote footnotes.
Parts List Revision History
Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 5
Unit Model & Serial Number Nomenclature
R D S 708 BUnit Model Number
RoofpakR= Roofpak Applied Rooftop
Unit ConfigurationD= Draw Thru Coil Section
Singlezone Unit
Unit Size708= Small Cabinet, 2,000 - 8000 CFM
Design Vintage
Serial Number- Until February, 19993 LA 12345 01
Factory 3= Faribault, MN
Year and Month of Manufacture YearA = 1971B = 1972C = 1973D = 1974E = 1975F = 1976G = 1977H = 1978J = 1979K= 1980L = 1981M = 1982N = 1983P = 1984Q = 1985
Engineering Revision Sequence
Serial Number- February, 1999 & LaterFBO U 99 05 04800
Plant IdentificationFBO = Faribault, MN
Year of Manufacture99 = 199900 = 200001 = 200102 = 200203 = 200304 = 200405 = 200506 = 200607 = 200708 = 200809 = 200910 = 2010
etc.
U= Unit
Serial Number (build sequence)Month of Manufacture01= January02= February03= March04= April05= May06= June 07= July08= August09= September10= October11= November12= December
Unit Serial Number
R = 1986S = 1987T = 1988U = 1989V = 1990W = 1991X = 1992Y = 1993Z = 19945 = 19956 = 19967 = 19978 = 19989 = 1999
Month A= JanuaryB= FebruaryC= MarchD= AprilE= MayF= JuneG= JulyH= AugustJ= SeptemberK= OctoberL= NovemberM= December
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 6
Unit Model Number- Complete
RDS708B Y 27 AL Y 1 YY Y A YYYY Y EA2F1 Y Y YY000 Y Y ED2F1 YY Code 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20
Unit Model Number- Complete 1, 2
YYYY YYYY Y YYYYYY EYYY A 1 YYYY Y Y Y 1250C 853C YYYY Y 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
Code 03= Blow Thru Blank/Empty Section Y= None B= 33" Blank/Empty Section After Supply Fan
Code 04= Unit Voltage 12= 208/60/3 29= 230/60/3 28= 380/50/3 27= 460/60/3 37= 575/60/3
Code 05= Starting Option AL= Across the Line XX= Special
Code 06= Electrical Power Package (In SAF Section) Y= None A= SAF Controls Only E= SAF & RAF Controls B= Purchased Control Box SAF Only w/ GE Components C= Purchased Control Box SAF Only w/ SE Components F= Purchased Control Box SAF & RAF w/ GE Components G= Purchased Control Box SAF & RAF w/ SE Components X= Special
Code 07= Insulation and Liners 1= 1" ¾lb. Fiberglass Insulation w/ no Liners 2= 1 ½" 1 ½lb. Insulation w/ Sold Liners 3= 1 ½" 1 ½lb. Insulation w/ Sold Liners/Perf. Liner in Plenum X= Special
Code 08= Inverter Digit 1: Inverter Function Y= None 6= Supply Fan (SAF) 7= Supply (SAF) & Return (RAF) Fans Digit 2: Inverter Brand Y= None A= ABB
Code 09= Fan Section Options Y= None A= SA Fan Section Light B= RA Fan Section Light C= SA & RA Fan Light X= Special
Code 10= Motor Type Y= Standard Efficiency ODP Motor A= 1800 RPM ODP Motor E= 1800 RPM ODP Hi-Efficiency Motor G= 1800 RPM TEFC Motor H= High Efficiency ODP Motor (Before 9/2000) H= 1800 RPM TEFC High Efficiency Motor (after 9/2000) J= 1800 RPM ODP Premium Efficiency Motor K= 1800 RPM TEFC Premium Efficiency Motor X= Special
Code 11= Final Filter Section YYYY= None AAAA= Blank 33" Section located after Heat Section BBBB= Final Filter 33" Section located after Heat Section BYYY= 33" Blank/Empty Section FEYY= 33" Final Filter Section w/ 95% Flat Cartridge Filters FYYY= 33" Final Filter Section XXXX= Special
Code 12= Belt Guard Y= None A= SA Fan Only B= RA Fan Only C= SA & RA Fans X= Special
Code 13= Supply Air (SA) Fan Drive Digit 1: Motor HP E= 1.0HP; F= 1.5HP; G= 2.0HP; H= 3.0HP; J= 5.0HP; K= 7.5HP; L= 10.0HP Digit 2: Fan Size A= 15" x 6" Fan B= 15" x 9" Fan C= 15" x 15" Fan E= 16" Fan Digit 3: Fan RPM (Minimum to Maximum Fan RPM Range) Digit 4: Wheel Type A= Airfoil Wheel, DW F= Forward Curved Wheel V= Airfoil Wheel, DW w/ Inlet Vanes G= Forward Curved Wheel w/ Inlet Vanes Digit 5: Fan Isolation 1= Rubber In Shear (RIS) 2= Spring 3= Spring w/ Seismic Snubbers
1 An "X" located in any position in a code string indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to use the Distributor Tools BOM Search function on the Daikin Parts website (for units built early 1999 or Later) or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
2 The code string shown above represents a typical code string for a unit built 1999 & Later. Several codes for units built 1999 & Earlier vary from what is shown.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 7
Unit Model Number- CompleteContinued
Code 14= Discharge Air Plenum Y= None G= Bottom H= Front R= Right Side Opening S= Left Side Opening D= Down Discharge X= Special
Code 15= Return Air Plenum Y= None G= Bottom H= Back J= 100% Hood w/ no Damper or RA Section K= 100% Hood w/ Damper, no RA Section T= Top X= Special
Code 16= Miscellaneous Controls/Unit Length Digit 1- 2: Optional Hardware YY= None YA= Bypass, SA Only YB= Bypass, SA & RA YC= Bypass, RA Only XX= Special Digit 3- 5: Unit Length YYY= Not a requirement ***= Unit Length in Inches XXX= Special
Code 17= Filters 1996 & Before 1
Y= None A= 2" Throwaway B= 2" Cleanable C= Bag Type, 45% w/o Prefilters D= Bag Type, 45% w/ Prefilters E= Bag Type, 95% w/ Prefilters F= A + B w/ No Filters provided G= 2" 35% Pleated Throwaway X= Special
Code 17= Filters 1999 & Later 1
Y= None A= Angular Rack w/ Throwaway Filters B= Angular Rack w/ Cleanable Filters C= Angular Rack Only G= Angular Rack w/ 30% Filters D= Flat Rack w/ 65% Cartridge Filters E= Flat Rack w/ 95% Cartridge Filters F= Flat Rack Only X= Special
Code 18= Damper Control 1996 & Earlier 1
Y= None A= 0- 30% Outdoor air w/ manual operation B= 0- 100% Outdoor air w/ manual operation & Economizer M= 0- 100% Outdoor/Return Air Mixing Box w/ Dampers X= Special
Code 18= Outside Air Options 1999 & Later 1
Y= None A= 0- 30% Outdoor air B= 0- 100% Economizer w/ Barometric Exhaust Damper M= 0- 100% Outdoor Air Mixing Box w/ Hood X= Special
Code 19= Return Air (RA) Fan Drive Digit 1: Motor HP E= 1.0HP; F= 1.5HP; G= 2.0HP; H= 3.0HP; J= 5.0HP X= Special Digit 2: Fan Size D= 15" x 15" Fan E= 16" Fan X= Special Digit 3: Fan RPM (Minimum to Maximum Fan RPM Range) Digit 4: Wheel Type A= Airfoil Wheel, DW F= Forward Curved Wheel V= Airfoil Wheel, DW w/ Inlet Vanes G= Forward Curved Wheel w/ Inlet Vanes X= Special Digit 5: Fan Isolation 1= Rubber In Shear (RIS) 2= Spring 3= Spring w/ Seismic Snubbers X= Special Code 20= Air Blender YY= None LC= Low CFM Air Blender XX= Special
Code 21= Auxiliary Section Digit 1: Blow Thru Coil Section Y= None A= 33" Section B= 48" Section X= Special Digit 2: Blank/Empty Section between Coil and Supply Air Fan Y= None A= 33" Section B= 48" Section X= Special Digit 3: Blank/Empty Section between Filter Section and Coil Y= None A= 33" Section B= 48" Section X= Special Digit 4: Blank/Empty Section between Economizer and Filter Section Y= None A= 33" Air Blender Section X= Special
1 Due to design overlap, if the unit was built 1996 thru 1999, it is necessary to physically determine what parts were installed or contact Daikin Applied with model and serial number information in order to ensure that the correct part(s) are ordered.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 8
Unit Model Number- CompleteContinued
Code 22= Contractor Coil Section 1996 & Earlier 1 Digit 1: Coil Type Y= None C= Contractor Coil F= Contractor Coil w/ Face & Bypass X= Special Digit 2: Finned Length Y= None S= 36.0" L= 48.0" X= Special Digit 3: Coil Position Y= None A= Position #1 B= Position #2 C= Position #1 & 2 D= Position #2 & 3 E= Position #1, 2, & 3 X= Special Digit 4: Filler Piece Height Y= None 1= 3.0" 2= 6.0" 3= 9.0" 4= 12.0" 5= 15.0" 6= 18.0" 7= 21.0" 8= 24.0" 9= 27.0" X= Special
Code 22= Contractor Coil Section 1999 & Later 1 Digit 1: Coil Type Y= None C= Contractor Coil w/ Galvanized Drain Pan D= Contractor Coil w/ Stainless Steel Drain Pan F= Contractor Coil w/ Galvanized Drain Pan & F & BP G= Contractor Coil w/ Stainless Steel Drain Pan & F & BP X= Special Digit 2: Finned Length Y= None S= 36.0" L= 48.0" X= Special Digit 3: Coil Position Y= None A= Position #1 B= Position #2 C= Position #1 & 2 D= Position #2 & 3 E= Position #1- 3 X= Special Digit 4: Coil Fin Height Y= 39.0" 1= 36.0" 2= 33.0" 3= 30.0" w/o F & B 4= 27.0" 5= 24.0" 6= 21.0" 7= 18.0" 8= 15.0" 9= 12.0" X= Special
Code 23= Disconnect Switch/Field Power Connection Y= None A= Disconnect Switch, Supply Air Fan E= Disconnect Switch, Supply & Return Air Fans P= Power Block X= Special
Code 24= Discharge Dampers YYYYYY= None (always 2000 & Later) D11111= Supply Air Dampers (1999 & Earlier) B11111= Supply & Return Air Dampers (1999 & Earlier) XXXXXX= Special
Code 25= Approval Listings YYYY= None EYYY= ETL/MEA USA CYYYY= ETL Canada XXXX= Special
Code 26= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total Z= Special
1 Due to design overlap, if the unit was built 1996 thru 1999, it is necessary to physically determine what parts were installed or contact Daikin Applied with model and serial number information in order to ensure that the correct part(s) are ordered.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 9
Code 27= Packaging 1= Steel Skid 2= Consolidated Ship w/ Steel Skid F= Sheathed Crate D= Open Crate
Code 28= Miscellaneous YYYY= None CCCC= Contractor Coil Sub-Item XXXX= Special
Code 29= Latest Code Sheet Revision 1996 & Earlier 1
(_)= Revision
Code 29= Position #1 Coil 1999 & Later 1
Y= None 1= With Coil
Code 30= Latest Engineering Revision 5/1999 & Before 1
(_)= Revision
Code 30= Position #2 Coil 5/1999 & Later 1
Y= None 1= With Coil
Code 31= Position #3 Coil Y= None 1= With Coil
Code 32= Supply Air Fan Drive Selection _ _ _ _ C Service Factor/Drive Type C= Std. SF/Variable Pitch Drive D= 150% SF/Variable Pitch Drive
XXXX= Special
Code 33= Return Air Fan Drive Selection YYYY= None _ _ _ _ C Service Factor/Drive Type C= Std. SF/Variable Pitch Drive D= 150% SF/Variable Pitch Drive
XXXX= Special
Code 34= Not an RDS708B Code Item YYYY= None
Code 35= Latest Code Sheet Revision Y= None
1 Due to design overlap, if the unit was built 1996 thru 1999, it is necessary to physically determine what parts were installed or contact Daikin Applied with model and serial number information in order to ensure that the correct part(s) are ordered.
RequiredRPM
RequiredRPM
Unit Model Number- CompleteContinued
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 10
Typical Unit Layout Diagrams 1
1 The above drawings are to be used for representative purposes only. Actual unit layout depends upon options selected.
100% Outside Air Hood w/ or w/o Dampers
Return Air Plenum
Return Air Plenum w/ 0- 30% Outside Air Hood
Return Air Plenum w/ 0- 100% Outdoor/Return Air Mixing Box
0- 100% Outdoor/Return Air Section w/ optional Return Air Fan
Discharge Plenum
Basic Front Discharge Unit
Down Discharge Unit
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 11
Schematic Sym. Description Location ACT3 1 Actuator Motor, Economizer Economizer Section ACT7 1 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 1 Actuator Motor, Cool Face/Bypass Coil Section, Cool CB1 Circuit Breaker, Main Power (for units with inverters) Power Panel/MC Box DAT 1 Sensor, Discharge Air Temperature Discharge Section DHL 1 Duct High Limit Power Panel/MC Box DS1 Disconnect, Total Unit Power Panel/MC Box EFT 1 Sensor, Entering Fan Air Temperature Supply Fan Section F1A, B, C Fuses, Control Circuit, T1 Power Panel/MC Box FB8, 13 Fuseblock, Transformer T1 Power Panel/MC Box FB9, 10 Fuseblock, Supply Fan Power Panel/MC Box FB11, 20 Fuseblock, Return Fan Power Panel/MC Box FS1, FS2 1 Freezestat Coil Section, Heat/Cool GRD Ground Power Panel/MC Box LT10- 23 Light, Cabinet Cabinet Sections OL1, OL3 Relay, Overload Power Panel/MC Box M10 Contactor, Supply Fan Power Panel/MC Box M20 Contactor, Return Fan/Supply Fan Power Panel/MC Box M22 Contactor, Return Fan Power Panel/MC Box MJ Mechanical Jumpers Terminal Blocks MMP10 Manual Motor Protector, Supply Fan Power Panel/MC Box MMP20 Manual Motor Protector, Return fan Power Panel/MC Box NB Neutral Bar Power Panel/MC Box OAT 1 Outside Air Temperature Sensor Economizer Section RAE 1 Return Air Enthalpy Sensor Return Air Section RAT 1 Return Air Temperature Sensor Return Air Section REC, REC1 Receptacle Power Panel/MC Box S1 Switch, System On/Off Power Panel/MC Box S10- 23 Switches, Cabinet Section Lights Cabinet Sections SD1 1 Smoke Detector, Supply Air Discharge Section SD2 1 Smoke Detector, Return Air Return Air Section T1 Transformer, Main Control Power Panel/MC Box TB1/PB1 Terminal Block/Power Block, Main Power Power Panel/MC Box TB2 Terminal Block, Field use Power Panel/MC Box TB3, 5, 6 Terminal Block, Factory Power Panel/MC Box TB7 Terminal Block, 115V Convenience Outlet Power Panel/MC Box VFD/AFD10 Inverter, Supply Fan Power Panel/MC Box VFD/AFD20 Inverter, Return Fan Power Panel/MC Box
Electrical Legend
1 Damper Actuators and Temperature Sensors are NORMALLY field supplied, or supplied as special order items. Schematic designators are given for reference only.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 12
Section A- Return Air SectionNotes
Primary Codes that pertain: 15, 18, 19, 33Additional Codes that pertain: 04, 06, 07, 08, 09, 10, 12, 24
Code 15 is for the Return Air Plenum and determines if the unit has back (horizontal) return air or bottom return air. Code 15 also determines if a 100% Outside Air Hood and/or Damper are installed. If Code 15= J, K the unit has no outside air option, AND Code 18 must be Y (no 0- 30% Outside Air OR 0- 100% Economizer with Barometric Exhaust).
Code 18 determines outdoor air options. Code 18= A indicates that the unit has 0- 30% outside air selected. If Code 18= B the unit has a 0- 100% Economizer with Barometric Exhaust in a 33" section and CANNOT have a Mixing Box. If Code 18= M the unit has a 0- 100% Mixing Box with Hood, and Code 15 MUST be G (bottom discharge).
Codes 19 & 33 determine the Return Air Fan Assembly, Motor, and Drive. Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Return Air Fan Motors range from 1- 5 horsepower, and the Fan Wheel can be either 15" x 15" Forward Curved (FC), OR a 16" Airfoil (AF). If Code 19= *D*G* OR *E*V*, Variable Inlet Vanes are present on the Return Fan. Note that the last unit supplied with Variable Inlet Vanes on the Return Air Fan was built in late 2007.
Code 04 specifies unit voltage. Unit voltage affects Fan Motor and Inverter (if supplied) part number identification.
Code 06 determines the options selected in the Electrical Power Package/Power Panel/Main Control Box.
Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration.
Code 08 determines if the Return Fan has an Inverter, or Variable/Adjustable Frequency Drive (VFD/AFD). If Code 08 does NOT equal YY, then the unit has inverters, and cannot have Fan Wheels with Variable Inlet Vanes. Inverters are not available on 575V units (Code 04= 37). For Inverter p/ns see Section G- Power Panel/Main Control Box.
Code 09 determines if the Return Air Cabinet has a Light Fixture, Light Switch, and 115V Receptacle.
Code 10 determines the type and efficiency rating of the Return Fan Motor.
Code 12 indicates whether the Return Fan is equipped with a Belt Guard. Code 12= B indicates that the Return Fan only has a Belt Guard, and Code 12= C indicates that both the Return and Supply Fan drives are equipped with a Belt Guard.
For units built 1999 and before, Code 24 indicates the presence of Return Air Fan Dampers. If Code 24= B11111, the Supply AND Return Fans are supplied with dampers.
➩
Note: Temperature and Air Pressure Sensors, and Damper Actuators are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 13
Section A- Return Air Section0- 30% Outside Air Damper with Hood
Code 18= A
2
11
4
Detail A
14
13
13
8
See Detail Below
Ref. Part Part Qty. No. Description Number 2 Damper/Hood Assy. 1 040559701 1 4 Outside Air Screen 040559400 1 8 Blade, Damper 040559000 1 10 Bearing, Flange Nylon 001113500 1 11 Bell Arm Assy. 027509300 1 13 Ball Joint 000887000 2 14 Rod, Damper 028680910 1
10
1 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item.
Outside Air Hood Detail
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 14
Section A- Return Air Section0- 100% Economizer with Hoods & Barometric Exhaust Damper
Code 18= B 3
Ref. Part Part Qty. No. Description Number 1 Damper Hood, Top Panel 040378101 3 2
2 Damper Hood, Side Panel 039659704 3 2
3 Damper Hood, Side Panel 039659703 3 2
6 Outside Air Screen 038634100 1 2
8 Damper, Barometric 1 038635201 3
6
3
2
1
8
1 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item. Note that the Damper is only on ONE side of the unit.
2 Qty. is for ONE assembly. There are TWO Hood assemblies in the unit.
3 See "Section B- Economizer Damper Section" for the Economizer Damper and related components.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 15
Section A- Return Air Section0- 100% Outside Air Damper with Hood: Code 15= K (After 3/04) 1, 4
& 100% Hood w/o Damper: Code 15= J 3, 4
1 The Damper Assembly used before 3/04 is obsolete and NO LONGER AVAILABLE. The Damper Assembly listed above is NOT a direct replacement and will NOT fit in units built before 3/04 WITHOUT FIELD MODIFICATIONS.
2 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item.3 When Code 15= J, use Damper Panel, Hood p/n 038633302. For additional parts, contact Daikin Applied with model and serial number
information.4 Note that when Code 15= J, K the unit does NOT have a Return Air Section. Instead, these units have a Return Air Plenum and Hood.
Ref. Part Part Qty. No. Description Number 3 Damper Panel, Hood 038633302 1 7 Outside Air Screen 251711001 1 10 Damper Assy., 44" x 32.5" 1, 2 251709301 1 21 Crank Arm 025072600 2
7
3
10
21
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 16
Section A- Return Air Section0- 100% Outside Air Damper Mixing Box with Hood
Code 18= M (After 3/04) 1
8
16 5
17
1819
1 The Damper Assembly used before 3/04 is obsolete and NO LONGER AVAILABLE. The Damper Assembly listed above is NOT a direct replacement and will NOT fit in units built before 3/04 WITHOUT FIELD MODIFICATIONS. Note that when replacing an original damper assembly, it is recommended to replace BOTH dampers at the same time so that the Damper Linkage will operate correctly.
2 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item.
Damper Linkage Detail
Ref. Part Part Qty. No. Description Number 5 Damper Panel, Hood 038633302 1 8 Outside Air Screen 040559400 1 16 Rod, Damper Linkage 028680934 1 17 Damper Assy., 48" x 22.5" 1, 2 251709101 2 18 Crank Arm 025072600 2 19 Ball Joint 000887000 2
1819
See Detail at Left
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 17
Section A- Return Air SectionReturn Fan Dampers: Code 24= B11111 1
1 Return Air Dampers are NOT available for units built 1999 and Later AND for 16" AF Wheel equipped units (Code 19= *E***). Diagram shows front OR horizontal discharge unit configuration (Code 14= H, Y). This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item.
11
Ref. Part Part Qty. No. Description Number 15" x 15" Fan Wheel Code 19= *D*** 11 Damper, Horizontal Discharge Code 14= H, Y 040202800 1 Damper, Downblast Discharge Code 14= D, G 040202500 1
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 18
Section A- Return Air SectionReturn Fan Assemblies
15" x 15" Forward Curved Fan w/o Variable Inlet Vanes- DiagramCode 19= *D*F*
Motor Sheave 1
Fan Sheave 1
1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
2
304
34
3
33
32
Motor(See Motor list at the
end of the Fan mounting section.)
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 19
Section A- Return Air Section Return Fan Assemblies
15" x 15" Forward Curved Fan w/o Variable Inlet Vanes- ComponentsCode 19= *D*F*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 033135100 1 3 Motor Mount 039614400 1 4 Shaft 039614701 1 30 Key- Motor Sheave 023221410 1 32 Bolt- Motor Mount 033453500 2 33 Key- Fan Sheave 023221409 1 34 Bearing 020648601 2 N/S Belt Guard 1 091529701 1N/S= Not Shown on diagram.Note: Motors are listed after the fan mounting section. Drive
components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Code 12= A, C.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 20
Section A- Return Air SectionReturn Fan Assemblies
15" x 15" Forward Curved Fans w/ Variable Inlet Vanes- DiagramsCode 19= *D*G*
73
68
74
76
67
Fan Sheave 1
Motor Sheave 1
2
54
9
3
7
74
76
79 78
75
75
8
Motor(See Motor list at the
end of the Fan mounting section.)
77
77
1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 21
Section A- Return Air SectionReturn Fan Assemblies
15" x 15" Forward Curved Fans w/ Variable Inlet Vanes- ComponentsCode 19= *D*G*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 033135100 1 3 Motor Mount 039614400 1 4 Shaft 066364101 1 5 Key- Motor Sheave 023221510 1 7 Bolt- Motor Mount 033453500 2 8 Key- Fan Sheave 023221409 1 9 Bearing 020648651 2 N/S Belt Guard 1 091529701 1 67 Inlet Vane Assy. CW 049752603 2 1 68 Inlet Vane Assy. CCW 049752604 2 1 73 Crankarm 066365001 1 74 Bearing, Flange 047138508 2 75 Shaft, Support 066364301 2 76 Ball Joint 000887000 6 77 Damper Rod 028680910 3 78 Mount, Actuator 066365201 1 79 Plate, Linkage 066365301 1N/S= Not Shown on diagram.Note: Motors are listed after the fan mounting section. Drive
components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information.
1 Code 12= A, C.2 Note that Inlet Vane Assemblies are obsolete and may no
longer be available. Contact Daikin Applied with model and serial number information BEFORE ordering.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 22
Section A- Return Air Section Return Fan Assemblies
16" Airfoil Fans w/o Variable Inlet Vanes- DiagramCode 19= *E*A* 1
8
13
4 5
7
9
2
3
Note: Horizontal Discharge arrangement shown.1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to
the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Motor(See Motor list at the
end of the Fan mounting section.)
11
9
29
30
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 23
Section A- Return Air Section Return Fan Assemblies
16" Airfoil Fans w/o Variable Inlet Vanes- ComponentsCode 19= *E*A*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 1 063006401 1 Housing Only 2 059382120 1 3 Motor Mount 059382105 1 4 Shaft 205983509 1 5 Key- Motor Sheave 023221405 1 7 Bolt- Motor Mount 033453500 2 8 Key- Fan Sheave 023221407 1 9 Bearing 020648651 2 11 Wheel 2 023392414 1 13 Cutoff Plate 2 027179103 1 29 Inlet Funnel 017898902 1 30 Inlet Funnel 017898902 1 N/S Belt Guard 3 091529801 1N/S= Not Shown on diagram.Note: Motors are listed after the fan mounting section. Drive
components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Assy. includes Housing, Wheel, Cutoff Plate, and Grease Tubing.
2 Included in Wheel/Housing Assy. 063006401.3 Code 12= A, C.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 24
Section A- Return Air Section Return Fan Assemblies
16" Airfoil Fans with Variable Inlet Vanes- DiagramsCode 19= *E*V* 1
Notes: Horizontal Discharge arrangement shown.1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to
the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Motor(See Motor list at the
end of the Fan mounting section.)
8
13
4 5
7
9
2
3
9
Inlet Guide Vane Detail(See the following two pages.)
7576
79
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 25
Section A- Return Air Section Return Fan Assemblies
16" Airfoil Fans with Variable Inlet Vanes- Diagrams, ContinuedCode 19= *E*V*
Inlet Guide Vane Detail
38
30
38
29
34
37
34A
34A
37
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 26
Section A- Return Air Section Return Fan Assemblies
16" Airfoil Fans with Variable Inlet Vanes- ComponentsCode 19= *E*V*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 1 063006401 1 Housing Only 2 059382120 1 3 Motor Mount 059382105 1 4 Shaft 205983509 1 5 Key- Motor Sheave 023221405 1 7 Bolt- Motor Mount 033453500 2 8 Key- Fan Sheave 023221407 1 9 Bearing 020648651 2 N/S Wheel 2 023392414 1 13 Cutoff Plate 2 027179103 1 29 Inlet Vane Assy. CW 024029705 5 1 30 Inlet Vane Assy. CCW 024029706 5 1 N/S Belt Guard 3 098795901 1 34 Linkage Rod Assy. 059382110 1 34A Bearing, Flange 4 047138508 2 37 Ball Joint 000887000 4 38 Linkage Rod 059370801 2 75 Ball Joint 000887000 2 76 Linkage Rod 055536614 1 79 Linkage Mount 059383801 1N/S= Not Shown on diagram.Note: Motors are listed after the fan mounting section. Drive
components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Assy. includes Housing, Wheel, Cutoff Plate, and Grease Tubing.
2 Included in Wheel/Housing Assy. 063006401.3 Code 12= A, C.4 Included in Linkage Rod Assy. 059382110.5 Note that Inlet Vane Assemblies are obsolete and may no
longer be available. Contact Daikin Applied with model and serial number information BEFORE ordering.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 27
Section A- Return Air SectionReturn Air Fan Mounting- 15" x 15" Forward Curved Fan
Code 19= *D*F1, *D*F2, *D*G1, *D*G2
Ref. Part Part Qty. 1
No. Description Number 46 Rubber Isolator R- 2 Blue 021639502 1 50 Screw .312-18 x 1.0" 048878113 4 51 Washer, Lock 048164810 4 52 Screw .375-16 x 1.0" 048878118 4 53 Nut 040499906 5 54 Washer, Lock 048164812 5
45
46
Rubber In Shear Code 19= *D*F1, *D*G1
50
4446
Spring Mounting Code 19= *D*F2, *D*G2
Ref. Part Part Qty.2
No. Description Number 43 Spring Isolator- w/o VIV Code 19= *D*F2 Motor H.P.= ALL Blue 039897300 1 Spring Isolator- w/ VIV Code 19= *D*G2 Motor H.P.= ALL Orange 039897400 1 44 Spring Isolator- w/o VIV Code 19= *D*F2 Motor H.P.= ALL Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *D*G2 Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 Brown 067005801 1 45 Spring Isolator- w/o VIV Code 19= *D*F2 Motor H.P.= ALL Blue 039897300 1 Spring Isolator- w/ VIV Code 19= *D*G2 Motor H.P.= ALL Blue 039897300 1 46 Spring Isolator- w/o VIV Code 19= *D*F2 Motor H.P.= ALL Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *D*G2 Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 5 Orange 039897400 1 47 Screw .500-13 x 1.0" 040499501 1 48 Washer 040500310 1 49 Washer, Lock 048164814 1 50 Screw .312-18 x 1.0" 048878113 2 51 Washer, Lock 048164810 2 52 Screw .375-16 x 1.0" 048878118 4 53 Nut 040499906 4 54 Washer, Lock 048164812 4
1 Quantity listed is for ONE corner. All four corners are the same.
43
5453
5251
5051
2 Quantity listed is for ONE corner. All four corners are the same.
53
54
47
49
48
50
52
51
53
54
52
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 28
142141
126
127
Section A- Return Air SectionReturn Air Fan Mounting- 15" x 15" Forward Curved Fan
Seismic Mounting: Code 19= *D*F3, *D*G3
45
4446
43
53
54
47
49
48
50
52
51
53
54
52
Ref. Part Part Qty. 1
No. Description Number 43 Spring Isolator- w/o VIV Code 19= *D*F3 Motor H.P.= ALL Blue 039897300 1 Spring Isolator- w/ VIV Code 19= *D*G3 Motor H.P.= ALL Orange 039897400 1 44 Spring Isolator- w/o VIV Code 19= *D*F3 Motor H.P.= ALL Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *D*G3 Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 Brown 067005801 1 45 Spring Isolator- w/o VIV Code 19= *D*F3 Motor H.P.= ALL Blue 039897300 1 Spring Isolator- w/ VIV Code 19= *D*G3 Motor H.P.= ALL Blue 039897300 1 46 Spring Isolator- w/o VIV Code 19= *D*F3 Motor H.P.= ALL Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *D*G3 Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 5 Orange 039897400 1 47 Screw .500-13 x 1.0" 040499501 1 48 Washer 040500310 1 49 Washer, Lock 048164814 1 50 Screw .312-18 x 1.0" 048878113 2 51 Washer, Lock 048164810 2 52 Screw .375-16 x 1.0" 048878118 4 53 Nut 040499906 4 54 Washer, Lock 048164812 4 126 Washer 057276701 2 127 Washer, Neoprene 067301101 2 128 Spacer, Neoprene 067301201 1 129 Spacer 057276801 1 141 Screw .750-10 x 3.0" 040499515 1 142 Washer, Lock 048164816 1 144 Washer 040500310 2 145 Washer, Lock 048164814 2 146 Nut 040500105 2 151 Screw 048878118 4 152 Washer, Lock 048164812 4
Seismic Mounting Detail
129127
126
144 145 146
128 152
151
1 Quantity listed is for ONE corner. All four corners are the same.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 29
Section A- Return Air SectionReturn Air Fan Mounting- 16" Airfoil Fan
Code 19= *E*A1, *E*A2, *E*V1, *E*V2
Spring Mounting Code 19= *E*A2, *E*V2
Rubber In Shear Code 19= *E*A1, *E*V1
Ref. Part Part Qty. 1
No. Description Number 46 Rubber Isolator R- 2 Blue 021639502 1 50 Screw .312-18 x 1.0" 048878113 4 51 Washer, Lock 048164810 4 52 Screw .375-16 x 1.0" 048878118 4 53 Nut 040499906 5 54 Washer, Lock 048164812 5
46
501 Quantity listed is for ONE corner. All four corners are the same. 54
5352
51
5051
45
4446
43
53
54
47
49
48
50
52
51
53
54
52
Ref. Part Part Qty.2
No. Description Number 43 Spring Isolator- w/o VIV Code 19= *E*A2 Motor H.P.= ALL Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *E*V2 Motor H.P.= ALL Orange 039897400 1 44 Spring Isolator- w/o VIV Code 19= *E*A2 Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 Brown 067005801 1 Spring Isolator- w/ VIV Code 19= *E*V2 Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 Brown 067005801 1 45 Spring Isolator- w/o VIV Code 19= *E*A2 Motor H.P.= ALL Blue 039897300 1 Spring Isolator- w/ VIV Code 19= *E*V2 Motor H.P.= ALL Blue 039897300 1 46 Spring Isolator- w/o VIV Code 19= *E*A2 Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 5 Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *E*V2 Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 5 Orange 039897400 1 47 Screw .500-13 x 1.0" 040499501 1 48 Washer 040500310 1 49 Washer, Lock 048164814 1 50 Screw .312-18 x 1.0" 048878113 2 51 Washer, Lock 048164810 2 52 Screw .375-16 x 1.0" 048878118 4 53 Nut 040499906 4 54 Washer, Lock 048164812 42 Quantity listed is for ONE corner. All four corners are the same.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 30
Section A- Return Air SectionReturn Air Fan Mounting- 16" Airfoil Fan
Seismic Mounting: Code 19= *E*A3, *E*V3
142141
126
127
45
4446
43
53
54
47
49
48
50
52
51
53
54
52
Ref. Part Part Qty. 1
No. Description Number 43 Spring Isolator- w/o VIV Code 19= *E*A3 Motor H.P.= ALL Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *E*V3 Motor H.P.= ALL Orange 039897400 1 44 Spring Isolator- w/o VIV Code 19= *E*A3 Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 Brown 067005801 1 Spring Isolator- w/ VIV Code 19= *E*V3 Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 Brown 067005801 1 45 Spring Isolator- w/o VIV Code 19= *E*A3 Motor H.P.= ALL Blue 039897300 1 Spring Isolator- w/ VIV Code 19= *E*V3 Motor H.P.= ALL Blue 039897300 1 46 Spring Isolator- w/o VIV Code 19= *E*A3 Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 5 Orange 039897400 1 Spring Isolator- w/ VIV Code 19= *E*V3 Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 5 Orange 039897400 1 47 Screw .500-13 x 1.0" 040499501 1 48 Washer 040500310 1 49 Washer, Lock 048164814 1 50 Screw .312-18 x 1.0" 048878113 2 51 Washer, Lock 048164810 2 52 Screw .375-16 x 1.0" 048878118 4 53 Nut 040499906 4 54 Washer, Lock 048164812 4 126 Washer 057276701 2 127 Washer, Neoprene 067301101 2 128 Spacer, Neoprene 067301201 1 129 Spacer 057276801 1 141 Screw .750-10 x 3.0" 040499515 1 142 Lock Washer 048164816 1 144 Washer 040500310 2 145 Washer, Lock 048164814 2 146 Nut 040500105 2
Seismic Mounting Detail
129127
126
144 145 146
128
1 Quantity listed is for ONE corner. All four corners are the same.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 31
Section A- Return Air SectionFan Motors 1
Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff H.P. Code 19 Voltage C10= H 2, E C10= J C10= H 3 C10= K C04= 12 1.0 E**** 208/60/3 098863300 205167600 040161000 046513001 1.5 F**** 208/60/3 098862500 205167500 098863400 4
2.0 G**** 208/60/3 039895700 046515500 049100300 4
3.0 H**** 208/60/3 039447500 065817100 047358100 065819400 5.0 J**** 208/60/3 039447600 065817200 049186800 065819500
C04= 29 1.0 E**** 230/60/3 039446200 205162800 040161000 046513000 1.5 F**** 230/60/3 4 019423600 046511100 046513100 2.0 G**** 230/60/3 039446300 205163500 047446000 073321000 3.0 H**** 230/60/3 039442400 065818100 049262300 065820100 5.0 J**** 230/60/3 039442500 065818200 040161200 065820200 C04= 27 1.0 E**** 460/60/3 039446200 205162800 040161000 046513000 1.5 F**** 460/60/3 4 019423600 046511100 046513100 2.0 G**** 460/60/3 039446300 205163500 047446000 073321000 3.0 H**** 460/60/3 039442400 065818100 049262300 065820100 5.0 J**** 460/60/3 039442500 065818200 040161200 065820200
C04= 37 1.0 E**** 575/60/3 049180800 206500900 049188000 206505600 1.5 F**** 575/60/3 049180900 206501600 049188100 205167800 2.0 G**** 575/60/3 049181000 205168300 049188200 046514400 3.0 H**** 575/60/3 046741600 046511700 049188300 046514500 5.0 J**** 575/60/3 046741900 205168900 049188400 0465146001 Note that Standard Efficiency Motors (Code 10= Y, A, G) are no longer available. Use HiEff or PrEff Motors (Code 10= E,
H, J, K) instead.2 Code used for units built before 9/2000. 3 Code used for units built after 9/2000.4 Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial
number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 32
Section A- Return Air SectionMiscellaneous Electrical Components: LT11, S11, REC11
Ref. Part Part Qty. No. Description Number 251 Light Fixture- LT11 6/13 & Earlier 042229500 1 Light Fixture- LT11 7/13 & Later 910145007 1 252 Bulb, incandescent 065492402 1 256 Box, Electrical 065491901 1 257 Cover, Electrical Box 065492001 1 258 Light Switch- S11 065492201 1 259 Receptacle- REC11 030187000 1
251252
256257See Detail at Right
258
259
Light Fixture Detail
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 33
Section B- Economizer Damper SectionNotes
Primary Codes that pertain: 15, 18Additional Codes that pertain: 07
Code 15 (Return Air Plenum) and Code 18 (Outdoor Air options for units built 1999 & Later) determine outside air options. If Code 18= B the unit has an Economizer and CANNOT have a Mixing Box. Code 15 CANNOT be Y (no Return Air Plenum/Section) if the unit has an Economizer.
Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration.
➩
Note: Temperature and Air Pressure Sensors, and Damper Actuators are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 34
Section B- Economizer Damper SectionEconomizer Dampers: Code 18= B 1
20
20
18
22
21
Ref. Part Part Qty. No. Description Number 18 Panel, Damper Support 46" x 12" 059375803 1 19 Panel, Damper Support 49" x 8" 045656303 1 21 Damper Assy, Low Leak 44.2" x 30.7" 045657701 1 7 Damper Blade, Low Leak 044195106 4 8 Linkage Bar, Damper 045657600 1 N/S Damper End Plug, Non Driven 041003501 4 17 Damper End Plug, w/ Drive Tab 041003502 4 18 Bushing, Damper Blade 043730400 8 19 Bushing, Damper Linkage 046098300 4 20 Gasket, Damper Blade 044193126 4 22 Damper Assy, Low Leak 44.2" x 30.7" 045657801 1 7 Damper Blade, Low Leak 044195106 4 8 Linkage Bar, Damper 045657600 1 N/S Damper End Plug, Non Driven 041003501 4 17 Damper End Plug, w/ Drive Tab 041003503 4 18 Bushing, Damper Blade 043730400 8 19 Bushing, Damper Linkage 046098300 4 20 Gasket, Damper Blade 044193126 4 24 Linkage Bar 059375701 1 25 Damper Rod 028680911 3 26 Ball Joint, Damper 000887000 6 27 Bushing, Damper Linkage 043734000 2 28 Locking Collar 049115902 1
719
191817
7
8
191817
20
N/S= Not shown on diagram.1 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or
supplied as a special order item.2 For the related Hood and Barometric Damper see the "0- 100% Economizer with Hoods & Barometric
Exhaust Damper" Section.
2425
26
27
28
See Detail at Left
Economizer Damper Detail
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 35
Primary Codes that pertain: 03, 11, 13, 17Additional Codes that pertain: 07
Codes 03 and 11 determine if the unit has a 33" Final Filter Section OR a 33" Blank/Empty Section. If Code 11= BBBB, F*** the unit has a Final Filter Section. When a Final Filter section is provided, a Blank/Empty Section and a Discharge Plenum are required. If Code 11= FE** the unit has a Final Filter Section located after the Heat Section equipped with 95% efficient Flat Cartridge Filters. If Code 11= AAAA OR B*** AND Code 03= B the unit is equipped with a 33" Blank/Empty Section located after the Heat Section. If Code 11= FY** a Filter Section and rack were included, but filter media was NOT factory supplied.
Code 17 determines Filter Section characteristics. Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 1996 and 1999, contact Daikin Applied with model and serial number information in order to ensure that the correct filters are identified. Also, some older design filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information.
For Units built 1996 & Before: Code 17= A= 2" Throwaway Filters B= 2" Cleanable Filters C= Bag Type, 45% w/o Prefilters D= Bag Type, 45% w/ Prefilters E= Bag Type, 95% w/ Prefilters F= A + B w/ No Filters provided G= 2" 35% Pleated Throwaway
For Units Built 1999 & Later: Code 17= A= Angular Rack w/ Throwaway Filters B= Angular Rack w/ Cleanable Filters C= Angular Rack Only G= Angular Rack w/ 30% Filters D= Flat Rack with 65% Cartridge Filters E= Flat Rack with 95% Cartridge Filters F= Flat Rack Only
Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration.
Section C- Filter/Final Filter SectionNotes
➩
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 36
Section C- Filter/Final Filter SectionFilter Section: 1996 & Before 1
15" x 6" FC Fans: Code 13= *A***
Ref. Part Part Qty./ No. Description Number Unit N/S Filter, Throwaway 20" x 25" x 2" 000016000 4 N/S Filter, Cleanable 20" x 25" x 2" 000095300 4 N/S Filter, Pleated Throwaway- 35% Efficient 20" x 25" x 2" 031298004 4 N/S Pre-Filter, Throwaway (For Bag Type) 12"x 24" x 2" 029217900 2 N/S Pre-Filter, Throwaway (For Bag Type) 24"x 24" x 2" 029218000 2 1 Filter, Bag Type- 45% Efficient 11.38" x 23.88" x 22" 033078825 1 2 Filter Basket- 45% Efficient 11.38" x 23.88" x 22" 033078826 1 3 Filter Frame- 45% Efficient 11.38" x 23.88" x 22" 033078815 1 4 Filter Retainer- 45% Efficient 11.38" x 23.88" x 22" 033078816 1 1 Filter, Bag Type- 45% Efficient 23.38" x 23.88" x 22" 033078827 1 2 Filter Basket- 45% Efficient 23.38" x 23.88" x 22" 033078828 1 3 Filter Frame- 45% Efficient 23.38" x 23.88" x 22" 033078819 1 4 Filter Retainer- 45% Efficient 23.38" x 23.88" x 22" 033078820 1 N/S Filter, Bag Type- 95% Efficient 24" x 24" x 26"/30" 029870204 2 N/S Filter, Blank- Flat or no Filters 19.62" x 25" 038636300 2 N/S Filter, Blank- 45% Efficient Bag Type 11.38" x 11.38" 038636200 1 N/S Filter, Blank- 45%/95 Efficient Bag Type 11.38" x 23.88" 038636000 1 N/S Filter, Blank- 45%/95 Efficient Bag Type 11.38" x 23.88" 038636100 1 N/S Filter, Blank- 45%/95 Efficient Bag Type 11.38" x 11.38" 038635900 1
43
2
1
N/S= Not shown on diagram.1 Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between
1996 and 1999, contact Daikin Applied with model and serial number information in order that the correct filters are identified. Also, some filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. Note that 16" Airfoil fans were not offered at this time.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 37
Section C- Filter/Final Filter SectionFilter Section: 1996 & Before, Continued 1
15" x 9" & 15" x 15" FC Fans: Code 13= *B***, *C***
43
2
1
Ref. Part Part Qty./ No. Description Number Unit N/S Filter, Throwaway 20" x 25" x 2" 000016000 6 N/S Filter, Cleanable 20" x 25" x 2" 000095300 6 N/S Filter, Pleated Throwaway- 35% Efficient 20" x 25" x 2" 031298004 6 N/S Pre-Filter, Throwaway (For Bag Type) 12"x 24" x 2" 029217900 3 N/S Pre-Filter, Throwaway (For Bag Type) 24"x 24" x 2" 029218000 2 1 Filter, Bag Type- 45% Efficient 11.38" x 23.88" x 22" 033078825 2 2 Filter Basket- 45% Efficient 11.38" x 23.88" x 22" 033078826 2 3 Filter Frame- 45% Efficient 11.38" x 23.88" x 22" 033078815 2 4 Filter Retainer- 45% Efficient 11.38" x 23.88" x 22" 033078816 2 1 Filter, Bag Type- 45% Efficient 23.38" x 23.88" x 22" 033078827 2 2 Filter Basket- 45% Efficient 23.38" x 23.88" x 22" 033078828 2 3 Filter Frame- 45% Efficient 23.38" x 23.88" x 22" 033078819 2 4 Filter Retainer- 45% Efficient 23.38" x 23.88" x 22" 033078820 2 N/S Filter, Bag Type- 95% Efficient 12" x 24" x 26"/30" 029870203 3 N/S Filter, Bag Type- 95% Efficient 12" x 24" x 26"/30" 029870204 1 1 Filter, Blank- 45%/95 Efficient 11.38" x 23.88" 038636100 1 1 Filter, Blank- 45%/95 Efficient 11.38" x 11.38" 038635900 1N/S= Not shown on diagram.1 Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between
1996 and 1999, contact Daikin Applied with model and serial number information in order that the correct Filters are identified. Also, some Filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information. Note that 16" Airfoil Fans were not offered at this time.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 38
Section C- Filter/Final Filter SectionFilter Section: Filters 1999 & Later 1
Angular Filter Section: Code 17= A, B, G
16
15
1 Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 1996 and 1999, contact Daikin Applied with model and serial number information in order that the correct Filters are identified. Also, some Filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information.
Ref. Part Code Part Qty. No. Description 17= Number 15" x 6" FC Fan: Code 13= *A*** 15 Filter Throwaway, MERV 6, 20 x 25 x 2" A 031298004 4 Throwaway, MERV 8, 20 x 25 x 2" G 111046307 4 Cleanable, 65%, 20 x 25 x 2" B 000095300 4 16 Filter, Blank Off ALL 038636300 2 15" x 9", 15 x 15" FC Fan: Code 13= *B***, *C** 15 Filter Throwaway, MERV 6, 20 x 25 x 2" A 031298004 4 Throwaway, MERV 8, 20 x 25 x 2" G 111046307 4 Cleanable, 65%, 20 x 25 x 2" B 000095300 4 16 Filter Throwaway, MERV 6, 20 x 25 x 2" A 031298004 2 Throwaway, MERV 8, 20 x 25 x 2" G 111046307 2 Cleanable, 65%, 20 x 25 x 2" B 000095300 2 16" AF Fan: Code 13= *E*** 15 Filter Throwaway, MERV 6, 20 x 25 x 2" A 031298004 4 Throwaway, MERV 8, 20 x 25 x 2" G 111046307 4 Cleanable, 65%, 20 x 25 x 2" B 000095300 4 16 Filter Throwaway, MERV 6, 20 x 25 x 2" A 031298004 2 Throwaway, MERV 8, 20 x 25 x 2" G 111046307 2 Cleanable, 65%, 20 x 25 x 2" B 000095300 2
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 39
2125
24
23
Cartridge Filter Section: Code 17= D, E
17
16
18
15
Section C- Filter/Final Filter SectionFilter Section: Filters 1999 & Later, Continued 1
20
22
19
1 Due to some design overlap during the transition from Bag to Cartridge Filters, for units built between 1996 and 1999, contact Daikin Applied with model and serial number information in order that the correct Filters are identified. Also, some Filters and related parts may be obsolete and no longer available. If this is the case, contact Daikin Applied for more information.
Ref. Part Code Part Qty. No. Description 17= Number 15" x 6" FC Fan: Code 13= *A*** 15, 19 Filter 24 x 24 x 12" 65% Efficient Cartridge D 065811002 2 95% Efficient Cartridge E 065811102 2 16, 20, 23 Filter 12 x 24 x 12" 65% Efficient Cartridge D 065811001 3 95% Efficient Cartridge E 065811101 3 15" x 9", 15 x 15" FC Fan: Code 13= *B***, *C** 15, 19 Filter 24 x 24 x 12" 65% Efficient Cartridge D 065811002 2 95% Efficient Cartridge E 065811102 2 16, 20, 23 Filter 12 x 24 x 12" 65% Efficient Cartridge D 065811001 3 95% Efficient Cartridge E 065811101 3 18 Pre-Filter 12 x 24 x 2" ALL 111046103 1 16" AF Fan: Code 13= *E*** 15, 19 Filter 24 x 24 x 12" 65% Efficient Cartridge D 065811002 2 95% Efficient Cartridge E 065811102 2 16, 20, 23 Filter 12 x 24 x 12" 65% Efficient Cartridge D 065811001 3 95% Efficient Cartridge E 065811101 3 17, 21 Pre-Filter 24 x 24 x 2" ALL 111046101 2 22, 25 Pre-Filter 12 x 24 x 2" ALL 111046103 2 24 Filter, Blank Off ALL 038635901 1
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 40
24
23
Final Filter Section: Code 11= FEYY
16
15
Section C- Filter/Final Filter SectionFilter Section: Filters 1999 & Later, Continued
20
19
Ref. Part Part Qty. No. Description Number 15 Filter, Cartridge, 95%, 24 x 24 x 12" 065811102 1 16 Filter, Cartridge, 95%, 12 x 24 x 12" 065811101 1 19 Filter, Cartridge, 95%, 24 x 24 x 12" 065811102 1 20 Filter, Cartridge, 95%, 12 x 24 x 12" 065811101 1 23 Filter, Cartridge, 95%, 12 x 24 x 12" 065811101 1 24 Filter, Blank Off, 12 x 24 x 12" 038635901 1
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 41
All RDS708B units that have heating or cooling capability are equipped with Contractor Coils. Contractor Coils are offered in multiple fin heights to allow the user to select the coil size to match the air flow. Contractor Coils generally offer a wider range of circuitings, rows and fins, and materials than the standard Unit Coil.
Contractor Coils are ordered as separate line items on the GO (General Order), so they DO NOT have orderable or "hard/permanent" part numbers. A Contractor coil is ALWAYS quoted as needed when needed.
When a replacement Coil is required a Contractor Coil quote needs to be prepared. To quote a replacement Contractor Coil it is necessary to obtain model and serial number information from the Unit Nameplate and then contact Daikin Applied. If the unit has more than one Coil it will be necessary to confirm which Coil(s) are needed BEFORE quoting.
Note that the sample code strings shown on the following page are INCOMPLETE and DO NOT furnish enough information for Daikin Applied to quote. GO and/or serial number information is required in order to properly quote a Contractor Coil.
Section D- Coil SectionNotes
Primary Codes that pertain: 22, 29, 30, 31Additional Codes that pertain: 07, 21
Code 22 determines Coil options, size, and Coil position in the DrawThru Coil Section. Code 22 also indicates whether the unit has a galvanized steel or stainless steel Drain pan, and if the unit is equipped with a Face and Bypass Damper. If Code 22= C***, F*** the unit has a galvanized steel Drain Pan. If Code 22= D***, G*** the unit has a stainless steel Drain pan. Code 22= F***, G*** indicates that the unit is equipped with a Face and Bypass Damper. Refer to the box below for information regarding ordering replacement coils.
Codes 29, 30, 31 (for units built 1999 & Later) indicate if a Contractor Coil is installed in coil positions one through three. Refer to the box below for information regarding ordering replacement coils for ALL RDS708B units.
Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration.
Code 21 gives information regarding the selection of auxiliary unit sections.
Also included in this section is the p/n for an optional field installed Piping Vestibule. A Piping Vestibule is recommended when piping must enter the side of the unit. It is also required on many coil arrangements to facilitate piping through the roof curb. The Vestibule listed is designed to fit a standard 48" Coil Section.
➩
Piping Vestibule
Typical Contractor Coil
Unit Cabinet
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 42
Section D- Coil SectionContractor Coil Code Strings 1
1 Note that these sample codes are incomplete and DO NOT provide sufficient information to quote a Coil. Refer to the notes on the previous page for information on having a Contractor Coil quoted.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 43
AirFlow
2
Coil(s)(refer to the Notes two
pages previous)
Section D- Coil SectionDrain Pans & Piping Vestibule
Ref. Part Part Qty. No. Description Number Drain Pan 2 Coil Finned Length 36" Galvanized Code 22= CS**, FS** 057433152 1 Stainless Steel Code 22= DS**, GS** 057433102 1 Coil Finned Length 48" Galvanized Code 22= CL**, FL** 057433151 1 Stainless Steel Code 22= DL**, GL** 057433101 1 3 Piping Vestibule Kit (field installed for a 48" Section) 058628105 1
Piping Vestibule
3
Coil Section
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 44
Section D- Coil SectionFace & Bypass Dampers
Ref. Part Part Qty. No. Description Number Damper, Face & Bypass 7 Coil Finned Length 36" Code 22= FS** 040377100 1 1 Coil Finned Length 48" Code 22= FL** 038632000 1 1
7
Drain Pan
1 This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item.
Coil(s)(refer to the Notes three
pages previous)
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 45
Section E- Supply Air SectionNotes
Primary Codes that pertain: 13, 32Additional Codes that pertain: 04, 06, 07, 08, 09, 10, 12, 24
Codes 13 & 32 determine the Supply Air Fan Assembly, Motor, and Drive Components. Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Fan Motors range from 1- 10 horsepower, and the Fan Wheel can be 15" x 6", 15" x 9", 15" x 15" Forward Curved (FC), OR 16" Airfoil (AF). Code 13 also determines if Variable Inlet Vanes (VIV) are present and what type of fan isolation is specified (Rubber-In-Shear OR Spring Isolators). If Code 13= ***G*, ***V*, Variable Inlet Vanes are present on the Supply Fan. Note that the last unit supplied with Variable Inlet Vanes in the Supply Air Section was built in late 2009.
Code 04 specifies unit voltage. Unit voltage affects the Supply Fan Motor and related part components.
Code 06 determines the options selected in the Electrical Power Package/Power Panel/Main Control Box.
Code 08 determines if the Supply Air Fan has an inverter, or Variable/Adjustable Frequency Drive (VFD/AFD). If Code 08 does NOT equal YY, then the unit has inverters, and cannot have Fan Wheels with Variable Inlet Vanes. Inverters are not available for 575V units (Code 04= 37). For inverter p/ns see Section G- Power Panel/Main Control Box.
Code 09 determines if the Supply Air Cabinet has a Light Fixture, Light Switch, and 115V Receptacle (Code 09= A, C).
Code 10 determines the type and efficiency rating of the Supply Air Fan Motor.
Code 12 indicates whether the Supply Fan is equipped with a Belt Guard. Code 12= A indicates that the Supply Fan has a Belt Guard. Code 12= C indicates that both the Supply and Return Fan drives are equipped with a Belt Guard.
Code 24 indicates the presence of Discharge Dampers. If Code 24= D11111, the Supply Air Section is supplied with a Damper. If Code 24= B11111, the Supply AND Return Sections are supplied with Dampers. Supply Air Dampers are not available with 16" AF Fan Wheels (Code 13= *E***) AND/OR on any unit built 1999 & Later.
➩
Note: Temperature and Air Pressure Sensors, and Damper Actuators are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 46
Section E- Supply Air SectionSupply Fan Dampers: Code 24= D11111, B11111 1
Ref. Part Part Qty. No. Description Number 11 15" x 6" Fan Wheel Code 13= *A*F* Damper, Horizontal Discharge Code 14= H, Y 040203000 1 Damper, Downblast Discharge Code 14= D, G 040202700 1 15" x 9" Fan Wheel Code 13= *B*F* Damper, Horizontal Discharge Code 14= H, Y 040202900 1 Damper, Downblast Discharge Code 14= D, G 040202600 1 15" x 15" Fan Wheel Code 13= *C*** Damper, Horizontal Discharge Code 14= H, Y 040202800 1 Damper, Downblast Discharge Code 14= D, G 040202500 1
11
1 Supply Air Dampers are not available for units built 1999 and Later and for 16" AF Wheel equipped units (Code 13= *E***). Diagram shows front OR horizontal discharge unit configuration (Code 14= H, Y). This Damper Assembly is set up for manual operation only. Any Actuators would be field supplied, or supplied as a special order item.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 47
Section E- Supply Air SectionFan Assemblies
15" Forward Curved Fans w/o Inlet Vanes- DiagramCode 13= *A*F*, *B*F*, *C*F*
5
9
7
3
4
2
8
Fan Sheave 1
Motor Sheave 1
Motor(See Motor list at the
end of the Fan mounting section.)
6
1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 48
Fan Size: Code 13= Qty. Ref. Part *A*F* *B*F* *C*F* No. Description 15 x 6" Fan 15 x 9" Fan 15 x 15" Fan 2 Wheel/Housing Assy. 039897500 039897600 033135100 1 3 Motor Mount 039614400 039614400 039614400 1 4 Shaft 039619701 039619801 039614701 1 5 Key- Motor Sheave 023221303 023221303 023221410 1 6 Shim- Bearing 040208900 040208900 Not Used 4 7 Bolt- Motor Mount 033453500 033453500 033453500 2 8 Key- Fan Sheave 023221309 023221309 023221409 1 9 Bearing- Pillow Block 020648661 1 020648661 1 020648651 1 2 N/S Belt Guard Assy 2 091529701 091529701 091529701 1N/S= Not Shown on diagram.Note: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave,
V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Some units may have setscrew locking style bearings installed. This concentric locking collar style bearing is the recommended replacement.
2 Code 12= A, C.
Section E- Supply Air SectionFan Assemblies
15" Forward Curved Fans w/o Inlet Vanes- ComponentsCode 13= *A*F*, *B*F*, *C*F*
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 49
Section E- Supply Air SectionFan Assemblies
15" x 15" Forward Curved Fan w/ Inlet Vanes- DiagramsCode 13= *C*G*
73
68
74
76
67
1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
5
9
7
3
4
2
Fan Sheave 1
Motor Sheave 1
74
76
79 78
75
75
8
Motor(See Motor list at the
end of the Fan mounting section.)
77
77
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 50
Section E- Supply Air SectionFan Assemblies
15" x 15" Forward Curved Fan w/ Inlet Vanes- ComponentsCode 13= *C*G*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 033135100 1 3 Motor Mount 039614400 1 4 Shaft 066364101 1 5 Key- Motor Sheave 023221410 1 7 Bolt- Motor Mount 033453500 2 8 Key- Fan Sheave 023221409 1 9 Bearing- Pillow Block 1 020648651 2 N/S Belt Guard 2 091529701 1 67 Inlet Vane Assy. CW 049752603 3 1 68 Inlet Vane Assy. CCW 049752604 3 1 73 Crankarm 066365001 1 74 Bearing, Flange 047138508 2 75 Shaft, Support 066364301 2 76 Ball Joint 000887000 6 77 Damper Rod 028680910 3 78 Mount, Actuator 066365201 1 79 Plate, Linkage 066365301 1N/S= Not Shown on diagram.Note: Motors are listed after the fan mounting section. Drive
components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Some units may have setscrew locking style bearings installed. This concentric locking collar style bearing is the recommended replacement.
2 Code 12= A, C.3 Note that Inlet Vane Assemblies are obsolete (last used in
2009) and may no longer be available. Contact Daikin Applied with model and serial number information BEFORE ordering.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 51
Section E- Supply Air SectionFan Assemblies
16" Airfoil Fans w/o Variable Inlet Vanes- DiagramCode 13= *E*A* 1
8
13
4 5
7
9
2
3
1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Motor(See Motor list at the
end of the Fan mounting section.)
11
9
29
30
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 52
Section E- Supply Air SectionFan Assemblies
16" Airfoil Fans w/o Variable Inlet Vanes- ComponentsCode 13= *E*A*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 1 063006401 1 Housing Only 2 059382120 1 Wheel Only 2 023392414 1 3 Motor Mount 059382105 1 4 Shaft 205983509 1 5 Key- Motor Sheave 023221405 1 7 Bolt- Motor Mount 033453500 2 8 Key- Fan Sheave 023221407 1 9 Bearing 3 020648651 2 11 Wheel 2 023392414 1 13 Cutoff Plate 2 027179103 1 29 Inlet Funnel 017898902 1 30 Inlet Funnel 017898902 1 N/S Belt Guard 4 091529801 1N/S= Not Shown on diagram.Notes: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-Belt(s),
and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Assy. includes Housing, Wheel, Cutoff Plate, and grease tubing.2 Included in Wheel/Housing Assy. 063006401.3 Some units may have setscrew locking style bearings
installed. This concentric locking collar style bearing is the recommended replacement.
4 Code 12= A, C.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 53
Section E- Supply Air SectionFan Assemblies
16" Airfoil Fans with Variable Inlet Vanes- DiagramsCode 13= *E*V* 1
1 Drive components (Fan Sheave, Motor Sheave, V-Belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Motor(See Motor list at the
end of the Fan mounting section.)
8
13
4 5
7
9
2
3
9
Inlet Guide Vane Detail(See the following two pages.)
7576
79
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 54
Section E- Supply Air SectionFan Assemblies
16" Airfoil Fans with Variable Inlet Vanes- Diagrams, ContinuedCode 13= *E*V*
Inlet Guide Vane Detail
38
30
38
29
34
37
34A
34A
37
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 55
Section E- Supply Air SectionFan Assemblies
16" Airfoil Fans with Variable Inlet Vanes- ComponentsCode 13= *E*V*
Ref. Part Part Qty. No. Description Number 2 Wheel/Housing Assy. 1 063006401 1 Housing Only 2 059382120 1 Wheel Only 2 023392414 1 3 Motor Mount 059382105 1 4 Shaft 205983509 1 5 Key- Motor Sheave 023221405 1 7 Bolt- Motor Mount 033453500 2 8 Key- Fan Sheave 023221407 1 9 Bearing 3 020648651 2 13 Cutoff Plate 2 027179103 1 29 Inlet Vane Assy. CW 024029705 6 1 30 Inlet Vane Assy. CCW 024029706 6 1 N/S Belt Guard 4 098795901 1 34 Linkage Rod Assy. 059382110 1 34A Bearing, Flange 5 047138508 2 37 Ball Joint 000887000 4 38 Linkage Rod 059370801 2 75 Ball Joint 000887000 2 76 Linkage Rod 055536614 1 79 Linkage Mount 059383801 1N/S= Not Shown on diagram.Notes: Motors are listed after the fan mounting section. Drive components (Fan Sheave, Motor Sheave, V-Belt(s),
and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required, use the Distributor Tools BOM Search function on the Daikin Parts website. If the Drive components are not found using the BOM Search function, use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1 Assy. includes Housing, Wheel, Cutoff Plate, and grease tubing.2 Included in Wheel/Housing Assy. 063006401.3 Some units may have setscrew locking style bearings
installed. This concentric locking collar style bearing is the recommended replacement.
4 Code 12= A, C.5 Included in assembly 059382110.6 Note that Inlet Vane Assemblies are obsolete (last used in
2009) and may no longer be available. Contact Daikin Applied with model and serial number information BEFORE ordering.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 56
Section E- Supply Air SectionSupply Air Fan Mounting
Diagrams
10
22
1819
23
24
1819
12
13
11
09
Rubber-In-Shear Code 13= ****1
Spring Mounting Code 13= ****2, ****3 1
1819
16
12
13
11
0914
15
1 For additional Seismic restraint parts refer to the chart four pages after next.
10
22
23
24
10
22
23
24
10
22
23
24
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 57
Ref. Part Part Qty. 1
No. Description Number 09 Mount 047146501 1 10 Isolator- 15x6, 15x9 Fan Code 13= *A*F1, *B*F1 Motor H.P.= ALL Blue 021639502 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F1 Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G1 Motor H.P.= ALL Blue 021639502 1 11 Screw 048878118 4 12 Nut, Hex 040499906 5 13 Lock Washer 040500212 5 18 Screw 048878113 2 19 Lock Washer 040500210 2 22 Isolator- 15x6, 15x9 Fan Code 13= *A*F1, *B*F1 Motor H.P.= ALL Blue 021639502 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F1 Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G1 Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 23 Isolator- 15x6, 15x9 Fan Code 13= *A*F1, *B*F1 Motor H.P.= ALL Blue 021639502 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F1 Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G1 Motor H.P.= ALL Blue 021639502 1 24 Isolator- 15x6, 15x9 Fan Code 13= *A*F1, *B*F1 Motor H.P.= ALL Blue 021639502 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F1 Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G1 Motor H.P.= ALL Blue 021639502 1
Rubber-In-Shear: Code 13= ****1
Section E- Supply Air SectionSupply Air Fan Mounting
15" Forward Curved Fans- ComponentsCode 13= *A*F*, *B*F*, *C*F*, *C*G*
1 Quantity listed is for ONE corner. All four corners are the same.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 58
Section E- Supply Air SectionSupply Air Fan Mounting
15" Forward Curved Fans- Components, ContinuedCode 13= *A*F*, *B*F*, *C*F*, *C*G*
Ref. Part Part Qty. 1
No. Description Number 09 Mount 047146501 1 10 Isolator- 15x6, 15x9 Fan Code 13= *A*F*, *B*F* Motor H.P.= 1 thru 5 Blue 039897300 1 Motor H.P.= 7.5 Orange 039897400 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F* Motor H.P.= 1 thru 3 Blue 039897300 1 Motor H.P.= 5 thru 10 Orange 039897400 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G* Motor H.P.= 1 thru 2 Blue 039897300 1 Motor H.P.= 3 thru 10 Orange 039897400 1 11 Screw 048878118 4 12 Nut, Hex 040499906 4 13 Lock Washer 040500212 4 14 Screw 040499501 1 15 Washer 040500310 1 16 Lock Washer 040500213 1 18 Screw 048878113 2 19 Lock Washer 040500210 2 22 Isolator- 15x6, 15x9 Fan Code 13= *A*F*, *B*F* Motor H.P.= 1 thru 5 Blue 039897300 1 Motor H.P.= 7.5 Orange 039897400 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F* Motor H.P.= 1 thru 3 Blue 039897300 1 Motor H.P.= 5 thru 10 Orange 039897400 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G* Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 thru 10 Brown 067005801 1 23 Isolator- 15x6, 15x9 Fan Code 13= *A*F*, *B*F* Motor H.P.= 1 thru 5 Blue 039897300 1 Motor H.P.= 7.5 Orange 039897400 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F* Motor H.P.= 1 thru 3 Blue 039897300 1 Motor H.P.= 5 thru 10 Orange 039897400 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G* Motor H.P.= 1 thru 3 Orange 039897400 1 Motor H.P.= 5 thru 10 Brown 067005801 1 24 Isolator- 15x6, 15x9 Fan Code 13= *A*F*, *B*F* Motor H.P.= 1 thru 5 Blue 039897300 1 Motor H.P.= 7.5 Orange 039897400 1 Isolator- 15x15 Fan w/o Inlet Vanes Code 13= *C*F* Motor H.P.= 1 thru 3 Blue 039897300 1 Motor H.P.= 5 thru 10 Orange 039897400 1 Isolator- 15x15 Fan w/ Inlet Vanes Code 13= *C*G* Motor H.P.= 1 thru 3 Blue 039897300 1 Motor H.P.= 5 thru 10 Orange 039897400 1
Spring: Code 13= ****2, ****3 2
1 Quantity listed is for ONE corner. All four corners are the same. 2 For a list of additional parts required for IBC seismic restraints see two pages atter next.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 59
Section E- Supply Air SectionSupply Air Fan Mounting
16" Airfoil Fan- ComponentsCode 13= *E*A*, *E*V*
Ref. Part Part Qty. 1
No. Description Number 09 Mount 047146501 1 10 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= ALL Blue 021639502 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= ALL Blue 021639502 1 11 Screw 048878118 4 12 Nut, Hex 040499906 5 13 Lock Washer 040500212 5 18 Screw 048878113 2 19 Lock Washer 040500210 2 22 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= 1 thru 5 Blue 021639502 1 Motor H.P.= 7.5 thru 10 Black 021639504 1 23 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= ALL Blue 021639502 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= ALL Blue 021639502 1 24 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= ALL Blue 021639502 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= ALL Blue 021639502 1
Rubber-In-Shear: Code 13= ****1
1 Quantity listed is for ONE corner. All four corners are the same.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 60
Section E- Supply Air SectionSupply Air Fan Mounting
16" Airfoil Fan- Components, ContinuedCode 13= *E*A*, *E*V*
Ref. Part Part Qty. 1
No. Description Number 09 Mount 047146501 1 10 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= 1 thru 3 Blue 039897400 1 Motor H.P.= 5 thru 10 Brown 067005801 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= 1 thru 3 Blue 039897400 1 Motor H.P.= 5 thru 10 Brown 067005801 1 11 Screw 048878118 4 12 Nut, Hex 040499906 4 13 Lock Washer 040500212 4 14 Screw 040499501 1 15 Washer 040500310 1 16 Lock Washer 040500213 1 18 Screw 048878113 2 19 Lock Washer 040500210 2 22 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= ALL Brown 067005801 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= ALL Brown 067005801 1 23 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= ALL Brown 067005801 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= ALL Brown 067005801 1 24 Isolator- 16" Fan w/o Inlet Vanes Code 13= *E*A* Motor H.P.= ALL Blue 039897400 1 Isolator- 16" Fan w/ Inlet Vanes Code 13= *E*V* Motor H.P.= ALL Blue 039897400 1
Spring: Code 13= ****2, ****3 2
1 Quantity listed is for ONE corner. All four corners are the same. 2 For a list of additional parts required for IBC seismic restraints see the following page.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 61
Ref. Part Part Qty. 1
No. Description Number 24 Channel Mount 3 058482201 1 25 Angle Mount 073390001 1 26 Washer- Neoprene 057276701 2 27 Washer- Neoprene 067301101 2 28 Spacer- Neoprene 067301201 1 29 Spacer- Steel 057276801 1 41 Cap Screw 040499515 1 42 Lock Washer 048164816 1 43 Mounting Plate 057346301 1 44 Washer 040500310 2 45 Washer- Locking 048164814 2 46 Nut 040500105 2 51 Cap Screw 3 048878118 4 52 Washer- Locking 3 048164812 41 Quantity listed is for ONE corner. All four corners are the same. 2 The above parts are required IN ADDITION to the previously listed spring isolator
components.3 Only used on 15" Fan Assemblies. Code 13- *A*F*, *B*F*, *C*F*, *C*G*.
Section E- Supply Air SectionSupply Air Fan Mounting
Additional Seismic Restraint Components 2
Code 13= ****3
24
25
43
4445 46
51
5251
52
51
52
24
2541
42
28
26
26
27
27
29
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 62
Section E- Supply Air SectionSupply Air Fan Motors 1
H.P. H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 13= Voltage C10= H 2, E C10= J C10= H 3 C10= K C04= 12 1.0 E**** 208/60/3 098863300 205167600 040161000 046513001 1.5 F**** 208/60/3 098862500 205167500 098863400 4
2 G**** 208/60/3 039895700 046515500 049100300 4
3 H**** 208/60/3 039447500 065817100 047358100 065819400 5 J**** 208/60/3 039447600 065817200 049186800 065819500 7.5 K**** 208/60/3 037530300 065817300 047665900 065819600 10 L**** 208/60/3 038999000 065817400 047666100 065819700
C04= 29 1.0 E**** 230/60/3 039446200 205162800 040161000 046513000 1.5 F**** 230/60/3 4 019423600 046511100 046513100 2 G**** 230/60/3 039446300 205163500 047446000 073321000 3 H**** 230/60/3 039442400 065818100 049262300 065820100 05 J**** 230/60/3 039442500 065818200 040161200 065820200 7.5 K**** 230/60/3 039448700 065818300 049100500 065820300 10 L**** 230/60/3 039446500 065818400 044691100 065820400 C04= 27 1.0 E**** 460/60/3 039446200 205162800 040161000 046513000 1.5 F**** 460/60/3 4 019423600 046511100 046513100 2 G**** 460/60/3 039446300 205163500 047446000 073321000 3 H**** 460/60/3 039442400 065818100 049262300 065820100 05 J**** 460/60/3 039442500 065818200 040161200 065820200 7.5 K**** 460/60/3 039448700 065818300 049100500 065820300 10 L**** 460/60/3 039446500 065818400 044691100 065820400
C04= 37 1.0 E**** 575/60/3 049180800 206500900 049188000 206505600 1.5 F**** 575/60/3 049180900 206501600 049188100 205167800 2 G**** 575/60/3 049181000 205168300 049188200 046514400 3 H**** 575/60/3 046741600 046511700 049188300 046514500 05 J**** 575/60/3 046741900 205168900 049188400 046514600 7.5 K**** 575/60/3 047443300 205168800 049188500 046514700 10 L**** 575/60/3 047443400 205168600 049188600 0658214001 Note that Standard Efficiency Motors (Code 10= Y, A, G) are no longer available. Use HiEff OR PrEff Motors (Code 10= E,
H, J, K) instead.2 Code used for units built before 9/2000. 3 Code used for units built after 9/2000.4 Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial
number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 63
Ref. Part Part Qty. No. Description Number 250 Bracket 065449000 1 251 Light Fixture- LT10 6/13 & Earlier 042229500 1 Light Fixture- LT10 7/16 & Later 910145007 1 252 Bulb, incandescent 065492402 1 256 Electrical Box 065491901 1 257 Electrical Box Cover 065492001 1 258 Light Switch- S10 065492201 1 259 Receptacle- REC10 030187000 1 402 Electrical Box Mount 065788401 1
250 251
256 257 258
Section E- Supply Air SectionMiscellaneous Electrical Components- LT10, S10, REC10
252
260259 402
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 64
Section F- Discharge Plenum SectionNotes
Primary Codes that pertain: 03, 11, 14Additional Codes that pertain: 07
Code 03 determines if the unit has a 33" Final Filter Section OR a 33" Blank/Empty Section after the Supply Air Section.
If Code 11= BBBB, F*** the unit has a Final Filter Section located after the Heat Section. When a Final Filter section is provided, a Blank/Empty Section and a Discharge Plenum are required.
Code 14 determines the discharge direction. Units may have bottom discharge (Code 14= G), front discharge (Code 14= H), right side discharge (Code 14= R), or left side discharge (Code 14= S). If Code 14= D, the unit has down discharge with no Discharge Plenum Section. In this case, the Discharge Opening is located in the Supply Fan Section.
Code 07 indicates the type of liners and insulation specified. This affects sheet metal panel p/ns and configuration.
➩
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 65
Section G- Power Panel/Main Control BoxNotes
Primary Codes that pertain: 04, 06, 08 13, 19, 23
The Power Panel/Main Control Box (referred to as the "Electrical Power Package" in Code 06), located in the Supply Air Section, has had a total of three different design versions.
1. The original Power Panel/Main Control Box design (Code 06= A, E) was used from the start of production through 03/05.
2. A major Power Panel/Main Control Box redesign was introduced 11/04. This Control Box (Code 06= B, F) uses General Electric components. This design was used until 10/06.
3. Beginning in 11/06, a change to Schneider Electric components was implemented (Code 06= C, G). Note that although GE and Schneider brand components are functional equivalents, they are NOT directly interchangeable. The part footprint varies and accessories, such as Contactor Auxiliaries, are not compatible with each other.
Code 04, determines unit voltage which affects Transformers, Contactors, Overloads and Overload Heaters, Motor Protectors, Fuses, and Inverters/VFDs.
Code 06 determines Electrical Power Package options and which generation of Control Box is installed. If Code 06= A the unit has Supply Air Fan controls. If Code 06= E, the unit has Supply AND Return Fan controls. If Code 06= B the unit has Supply Air Fan controls with GE components. If Code 06= F the unit has Supply AND Return Fan controls with GE components. If Code 06= C the unit has Supply Air Fan controls with Schneider Electric components. If Code 06= F the unit has Supply AND Return Fan controls with Schneider Electric components. If Code 06= Y (no Power Package) then Code 23 (Disconnect Switch & field power connection) must also be Y.
Code 08 determines if the unit is equipped with inverter(s) (VFD/AFD). Starting in late 2004, if Code 08= 6A, the unit has an ABB brand inverter on the Supply Fan. Also starting in late 2004, if Code 08= 7A, the unit has an ABB brand inverter on both the Supply AND Return Fans. Note that some units may have had an inverter installed before late 2004 with the inverter marked as a special feature (Code 08= YY AND Code 28= XXXX). If the unit is equipped with inverter(s) it will have a Circuit Breaker (CB1) NOT a total unit Disconnect (DS1).
The first digit of Codes 13 AND 19 determines what horsepower fan motor(s) are installed. The horsepower of the Fan Motor determines the size and rating of the Fan Contactor, Overload (OL), Overload Heater, Motor Protector (MMP), and inverter (VFD/AFD).
Code 23 indicates whether or not the unit has a factory mounted Disconnect Switch, Circuit Breaker, OR Power Block. If Code 23= A the unit has one Disconnect Switch for units w/o an inverter or one Circuit Breaker for the Supply Fan for units w/ an inverter. If Code 23= E, the unit has a single Disconnect Switch for units w/o inverters or one Circuit Breaker for units w/ inverters for both the Supply AND Return Fans. If Code 23= P, the unit is equipped with a single Power Block.
➩
Note: Temperature and Air Pressure Sensors are NOT normally factory supplied. If such parts are present they would have been special order items, or they would have been field supplied. Contact Daikin Applied with model and serial number information as well as all available vendor and p/n information to see if the required part(s) can be identified and sourced.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 66
Section G- Power Panel/Main Control BoxPower Panel: Code 06= A, E: Diagram 1
1 The above drawing is representative of a typical Power Panel/Main Control Box for a unit equipped with Supply and Return Fan controls (Code 06= E). Note that components and component layout will vary depending upon unit options selected.
2 Schematic Designator M20 has been used for BOTH Supply and Return Fan Contactors.
FB11 ORFB20 FB9 OR
FB10T1
FB8OR
FB13
M10 ORM20 2
M20 ORM22 2
OL1OL3
TB1, PB1ORDS1
NB
F1
S1
REC/REC1
TB2TB1
(Used when PB1 or DS1 is present)
Return FanSide
Supply FanSide
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 67
Section G- Power Panel/Main Control BoxPower Panel (Code 06= A, E): Common Components
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V System Stop Switch S1 Switch- SPST 802005045 1 1 1 1 Terminal Blocks TB1/PB1 Terminal/Power Block- 3P 175A, 600V 030372710 1 1 1 1 TB2 Terminal Block- 14P 20A 022431214 1 1 1 1 Transformer- Main T1 Transformer 038253913 1 1 Transformer 038253904 1 1 Fuse Block/Fuse- Control 1
FB1 Fuse Holder- Control 1 15A, 300V 802007553 1 1 1 1 Fuse- Control 1 15A 049128306 1 1 1 1 Fuse Block/Fuse- Transformer FB8, 13 Fuse Holder-Transformer 30A, 250V 023780202 1 1 Fuse Holder-Transformer 30A, 600V 023780203 1 1 Fuse- Transformer 15A, 250V 025860505 1 1 Fuse- Transformer 15A, 600V 025860405 1 1 REC/REC1 Receptacle Receptacle 115V 025283700 1 1 1 1 Neutral Bar NB Neutral Bar 037530800 3 1 1 1 1 Disconnect Switch DS1 Disconnect Switch- 3P 60A, 600V 031446200 1 1 1 1 Mechanism Only 031322400 1 1 1 1 Handle Only 025862300 1 1 1 1 Shaft Only 2 6.53" 025862600 1 1 1 11 Note that the original Fuseholder is obsolete and no longer available. The old and new Fuse and Fuseholder are NOT
interchangeable. If replacement of the Fuseholder is required, then also order Fuse 049128306. If the unit has the original Fuseholder p/n 029552200, order Fuse 036559100.
2 This Shaft is designed to be cut to the appropriate length to accommodate various mounting positions.3 This part may no longer be available. Contact Daikin Applied with model and serial number information to confirm part
availability BEFORE ordering.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 68
Section G- Power Panel/Main Control BoxPower Panel (Code 06= A, E): Fan Motor Contactors, Overloads,
& Fusing Components
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors- SAF (M10, 20) OR RAF (M20, 22) Motor 2 M10, 20, 22 Contactor, w/ Auxiliary 027514401 1 1 1 1 Contactor, w/o Auxiliary 027514101 1 1 1 1 Fuse Block and Fuses FB9- 20 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780204 1 1 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780205 1 1 Fuse 025860505 3 3 Fuse 025860405 3 3 Overloads and Heaters OL1, 3 Overload- Supply (OL1), Return (OL3) Fan Motor 1 1 1 1 1 Heater, Overload- OL1 OR OL3 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
1.0 Horsepower Supply AND/OR Return Fan Motor- Code 13 OR 19= E****
1.5 Horsepower Supply AND/OR Return Fan Motor- Code 13 OR 19= F****
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors- SAF (M10, 20) OR RAF (M20, 22) Motor 2 M10, 20, 22 Contactor, w/ Auxiliary 027514401 1 1 1 1 Contactor, w/o Auxiliary 027514101 1 1 1 1 Fuse Block and Fuses FB9- 20 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780204 1 1 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780205 1 1 Fuse 025860505 3 3 Fuse 025860405 3 3 Overloads and Heaters OL1, 3 Overload- Supply (OL1), Return (OL3) Fan Motor 1 1 1 1 1 Heater, Overload- OL1 OR OL3 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
NOTE: Quantities Listed are PER motor.1 Note that there have been two different series of Overloads and Overload heaters used during the production run.When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the
existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY.
Once vendor and amperage information is obtained, contact Daikin Applied for p/ns.2 Schematic Designator M20 has been used for BOTH Supply and Return Fan Contactors.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 69
2.0 Horsepower Supply AND/OR Return Fan Motor- Code 13 OR 19= G****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= A, E): Fan Motor Contactors, Overloads,
& Fusing Components, Continued
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors- SAF (M10, 20) OR RAF (M20, 22) Motor 2 M10, 20, 22 Contactor, w/ Auxiliary 027514401 1 1 1 1 Contactor, w/o Auxiliary 027514101 1 1 1 1 Fuse Block and Fuses FB9- 20 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780204 1 1 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780205 1 1 Fuse 025860505 3 3 Fuse 025860405 3 3 Overloads and Heaters OL1, 3 Overload- Supply (OL1), Return (OL3) Fan Motor 1 1 1 1 1 Heater, Overload- OL1 OR OL3 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors- SAF (M10, 20) OR RAF (M20, 22) Motor 2 M10, 20, 22 Contactor, w/ Auxiliary 027514401 1 1 1 1 Contactor, w/o Auxiliary 027514101 1 1 1 1 Fuse Block and Fuses FB9- 20 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780204 1 1 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780205 1 1 Fuse 025860505 3 3 Fuse 025860405 3 3 Overloads and Heaters OL1, 3 Overload- Supply (OL1), Return (OL3) Fan Motor 1 1 1 1 1 Heater, Overload- OL1 OR OL3 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
3.0 Horsepower Supply AND/OR Return Fan Motor- Code 13 OR 19= H****
NOTE: Quantities Listed are PER motor.1 Note that there have been two different series of Overloads and Overload heaters used during the production run.When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the
existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY.
Once vendor and amperage information is obtained, contact Daikin Applied for p/ns.2 Schematic Designator M20 has been used for BOTH Supply and Return Fan Contactors.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 70
5.0 Horsepower Supply AND/OR Return Fan Motor- Code 13 OR 19= J****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= A, E): Fan Motor Contactors, Overloads,
& Fusing Components, Continued
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors- SAF (M10, 20) OR RAF (M20, 22) Motor 2 M10, 20, 22 Contactor, w/ Auxiliary 027514401 1 1 1 1 Contactor, w/o Auxiliary 027514101 1 1 1 1 Fuse Block and Fuses FB9- 20 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780204 1 1 Fuse Block- Supply (FB9, 10), Return (FB11, 20) 023780205 1 1 Fuse 025860507 3 Fuse 025860506 3 Fuse 025860405 3 3 Overloads and Heaters OL1, 3 Overload- Supply (OL1), Return (OL3) Fan Motor 1 1 1 1 1 Heater, Overload- OL1 OR OL3 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
7.5 Horsepower Supply Fan Motor- Code 13= K****
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M10, 20 Contactor- Supply Fan Motor 027514402 1 Contactor- Supply Fan Motor 027514401 1 1 1 Fuse Block and Fuses FB9, 10 Fuse Block- Supply Fan Motor 023780204 1 1 Fuse Block- Supply Fan Motor 023780205 1 1 Fuse 025860509 3 3 Fuse 025860405 3 3 Overload and Heater OL1 Overload- Supply Fan Motor 1 1 1 1 1 Heater, Overload- Supply Fan Motor 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
NOTE: Quantities Listed are PER motor.1 Note that there have been two different series of Overloads and Overload heaters used during the production run.When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the
existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY.
Once vendor and amperage information is obtained, contact Daikin Applied for p/ns.2 Schematic Designator M20 has been used for BOTH Supply and Return Fan Contactors.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 71
10 Horsepower Supply Fan Motor- Code 13= L****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= A, E): Fan Motor Contactors, Overloads,
& Fusing Components, Continued
Schem. Part Part Voltage Sym. Description Number 208V 230V 380V 460V Contactors M10, 20 Contactor- Supply Fan Motor 027514403 1 Contactor- Supply Fan Motor 027514402 1 Contactor- Supply Fan Motor 027514401 1 1 Fuse Block and Fuses FB9, 10 Fuse Block- Supply Fan Motor 023780209 1 1 Fuse Block- Supply Fan Motor 023780205 1 1 Fuse 025860511 3 Fuse 025860510 3 Fuse 025860406 3 3 Overload and Heater OL1 Overload- Supply Fan Motor 1 1 1 1 1 Heater, Overload- Supply Fan Motor 1 1 1 1 1 N/S Relay, Overload Reset 025955300 1 1 1 1
NOTE: Quantities Listed are PER motor.1 Note that there have been two different series of Overloads and Overload heaters used during the production run.When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the
existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY.
Once vendor and amperage information is obtained, contact Daikin Applied for p/ns.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 72
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Diagrams 1
DS1 OR PB1
GLG1
TB7
TB4
TB2
MMP20 MMP10
M20 M10
S1
REC1
T1F1AF1BF1C
DS1 OR PB1 OR CB1
GLG1
TB7
TB4
TB2
VFD20 VFD10
F20
1 2 3
S1
REC1
T1F1AF1BF1C
GRD20 GRD10
Power Panel/Main Control Box w/o VFD/AFD
Power Panel/Main Control Box w/ VFD/AFD
1 The above drawings are to be used for representative purposes only. Components and component layout vary depending upon unit options selected.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 73
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Common Components 1
Schem. Part Part Voltage Sym. Description Number 208V 230V 460V 575V S1 System Switch 001355000 1 1 1 1 Terminal Blocks 2
TB2 Terminal Block Assy., Main Power Terminal Block, Green 2 Port 349930603 2 2 2 2
Terminal Block, Grey 2 Port 349930604 2 2 2 2
Terminal End Stop 349930801 2 2 2 2
Terminal Barrier 349930701 2 2 2 2
TB4 Terminal Block Assy, Factory use Terminal Block, Green 349930603 2 2 2 2
Terminal Block, Grey 349930604 2 2 2 2
TB7 Terminal Block Assy., Convenience Outlet (REC1) Terminal Block, Green 2 Port 349930604 1 1 1 1 Terminal Block, Grey 2 Port 349930603 2 2 2 2
Terminal End Stop 349930801 2 2 2 2 Terminal Barrier 349930701 1 1 1 1 Transformer- Main T1 Transformer, Main Control- .5 kVA 300041200 1 Transformer, Main Control- .5 kVA 038253988 1 1 1 Fuses- T1 F1A, B Fuse- T1 Transformer, Primary 349937125 2 Fuse- T1 Transformer, Primary 349937124 2 2 Fuse- T1 Transformer, Primary 349937123 2 F1C Fuse- T1 Transformer, Secondary 349937029 1 1 1 1 Fuse Puller/Cover 349938207 1 1 1 1 Fuse- VFD/AFD, Return Fan Code 08= *A FB20 Fuse Block 023780232 1 1 1 1 Fuse Puller/Cover 349938207 3 3 3 3 Fuse Fuse- Motor H.P.= 1 Code 19= E**** 349937125 3 3 Fuse- Motor H.P.= 1 Code 19= E**** 349937120 3 Fuse- Motor H.P.= 1 Code 19= E**** 349937116 3 Fuse- Motor H.P.= 1.5 Code 19= F**** 349937129 3 3 Fuse- Motor H.P.= 1.5 Code 19= F**** 349937123 3 Fuse- Motor H.P.= 1.5 Code 19= F**** 349937120 3 Fuse- Motor H.P.= 2.0 Code 19= G**** 349937131 3 Fuse- Motor H.P.= 2.0 Code 19= G**** 349937130 3 Fuse- Motor H.P.= 2.0 Code 19= G**** 349937124 3 Fuse- Motor H.P.= 2.0 Code 19= G**** 349937123 3 Fuse- Motor H.P.= 3.0 Code 19= H**** 349937133 3 3 Fuse- Motor H.P.= 3.0 Code 19= H**** 349937127 3 Fuse- Motor H.P.= 3.0 Code 19= H**** 349937124 3 Fuse- Motor H.P.= 5.0 Code 19= J**** 349937136 3 Fuse- Motor H.P.= 5.0 Code 19= J**** 349937135 3 Fuse- Motor H.P.= 5.0 Code 19= J**** 349937132 3 Fuse- Motor H.P.= 5.0 Code 19= J**** 349937129 3 1 This table lists the most commonly offered Power Panel/Main Control Box components. For components not listed here, contact
Daikin Applied with model and serial number information (and vendor p/n information- if available) to ensure that the correct part(s) are identified.
2 Terminal Block assemblies are made up of the components listed. The number AND quantity of parts used varies depending upon unit options selected. Confirm how many of each part(s) are needed BEFORE ordering.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 74
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Common Components, Continued 1
REC1 Receptacle, Ground Fault 039003600 1 1 1 1 GLG1 Ground Lug 349938001 1 1 1 1 Power Block PB1 Power Block, Main Power 030372705 1 1 1 1 Cover- Power Block 349938301 1 1 1 11 This table lists the most commonly offered Power Panel/Main Control Box components. For components not listed here, contact
Daikin Applied with model and serial number information (and vendor p/n information- if available) to ensure that the correct part(s) are identified.
Schem. Part Part Voltage Sym. Description Number 208V 230V 460V 575V
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 75
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Disconnect Switch DS1 (Code 08= YY)
3
2
1
4
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 Lug 349935901 6 6 6 6 2 DS1 Disconnect Switch- Main 1 100A 349935101 1 1 1 1 3 Screw 349906201 3 3 3 3 4 Handle Mechanism 349935501 1 1 1 1
208V
230V
460V
575V
1 100A is the most commonly offered Disconnect Switch size. Confirm amperage required BEFORE ordering, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 76
3
2
1
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 Lug 349935901 1 1 1 1
2 CB1 Circuit Breaker- Main Motor HP= 1 thru 7.5 349936601 1 1 1 1 Motor HP= 10 349936602 1 1 Motor HP= 10 349936601 1 1 3 Screw, Ring Terminal 349906201 2 2 2 2
4 Handle Mechanism 3 349935501 1 1 1 1 5 Rating Plug Motor HP= 1 thru 10 4 1 1 1 1
208V
230V
460V
575V
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Circuit Breaker CB1 (Code 08= *A) 5
4
1 Quantity of 6 pc. if Lugs only are used. Quantity of 3pc. if Lugs and Ring Terminals are used.2 Quantity of 0 pc. if Lugs only are used. Quantity of 3pc. if Lugs and Ring Terminals are used. Ring Terminals are field supplied.3 Field cut shaft to required length.4 Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.5 Circuit Breaker CB1 is used in place of a Disconnect Switch (DS1) for units with inverters (VFD/AFDs).
5
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 77
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Diagram & Components 1
3C
2
3D
3A
1A
3B
1
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932101 1 1 1 1 1A Cover- Contactor 349932801 1 1 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934008 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934007 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934006 1 3A Line Shield 349933001 1 1 1 1 3B Link 300041307 1 1 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3D Aux. Interlock- 1 NO/1 NC 349933902 1 1 1 1
208V
230V
460V
575V
1 HP Motor- Code 13 OR 19= E****
1 The diagram and table show all possible parts. Not every part shown is used on every unit/voltage combination.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 78
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932101 1 1 1 1 1A Cover- Contactor 349932801 1 1 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934009 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934007 1 1 3A Line Shield 349933001 1 1 1 1 3B Link 300041307 1 1 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3D Aux. Interlock- 1 NO/1 NC 349933902 1 1 1 1
208V
230V
460V
575V
1.5 HP Motor- Code 13 OR 19= F****
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932102 1 1 1 1 1A Cover- Contactor 349932801 1 1 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934010 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934009 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934008 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934007 1 3A Line Shield 349933001 1 1 1 1 3B Link 300041307 1 1 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3D Aux. Interlock- 1 NO/1 NC 349933902 1 1 1 1
208V
230V
460V
575V
2 HP Motor- Code 13 OR 19= G****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Supply MMP10 & M10 Fan Contactor,
& Return MMP20 & M20 Fan Contactor- Components 1
1 The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 79
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932102 1 1 1 1 1A Cover- Contactor 349932801 1 1 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934010 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934009 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934008 1 3A Line Shield 349933001 1 1 1 1 3B Link 300041307 1 1 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3D Aux. Interlock- 1 NO/1 NC 349933902 1 1 1 1
208V
230V
460V
575V
3 HP Motor- Code 13 OR 19= H****
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932301 1 Contactor- Supply (M10) OR Return (M20) Fan 349932201 1 Contactor- Supply (M10) OR Return (M20) Fan 349932102 1 1 1A Cover- Contactor 349932803 1 Cover- Contactor 349932802 1 Cover- Contactor 349932801 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934012 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934010 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934009 1 3A Line Shield 349933001 1 1 1 1 3B Link 349932904 1 Link 300041307 1 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3D Aux. Interlock- 1 NO/1 NC 349933902 1 1 1 1
208V
230V
460V
575V
5 HP Motor- Code 13 OR 19= J****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 1
1 The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 80
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932401 1 Contactor- Supply Fan 349932301 1 Contactor- Supply Fan 349932102 1 1 1A Cover- Contactor 349932804 1 Cover- Contactor 349932803 1 Cover- Contactor 349932801 1 1 2 MMP10 MMP- Supply Fan 349934105 1 MMP- Supply Fan 349934014 1 MMP- Supply Fan 349934011 1 MMP- Supply Fan 349934010 1 3A Line Shield 2 349933001 1 1 1 3B Link 349932906 1 Link 349932904 1 Link 300041307 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3E OL Circuit Alarm- Front 349933804 1
208V
230V
460V
575V
7.5 HP Motor- Code 13= K**** 3
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 1
3B
1
1A
2
3E
3C
1 The diagram and table show all possible parts. Not every part shown applies to every unit/voltage combination. 2 Line Shield may have been used on early production units during this period.3 Note that 7.5 HP motors are NOT available for Return Fans.
3A
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 81
Section G- Power Panel/Main Control BoxPower Panel (Code 06= B, F): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 1
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932501 1 1 Contactor- Supply Fan 349932201 1 Contactor- Supply Fan 349932102 1 1A Cover- Contactor 349932805 1 1 Cover- Contactor 349932802 1 Cover- Contactor 349932801 1 2 MMP10 MMP- Supply Fan 349934106 1 1 MMP- Supply Fan 349934012 1 MMP- Supply Fan 349934011 1 3A Line Shield 2 349933001 1 1 3B Link 349932907 1 1 Link 300041307 1 1 3C Short Circuit Alarm 349933903 1 1 1 1 3E OL Circuit Alarm- Front 349933804 1 1 1 1
208V
230V
460V
575V
10 HP Motor- Code 13= L**** 3
1 The diagram and table show all possible parts. Not every part shown applies to every unit/voltage combination. 2 Line Shield may have been used on early production units during this period.3 Note that 10 HP motors are NOT available for Return Fans.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 82
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Diagrams 1
DS1 OR PB1
GLG1
TB7
TB4
TB2
MMP20 MMP10
M20 M10
S1
REC1
T1F1AF1BF1C
DS1 OR PB1 OR CB1
GLG1
TB7
TB4
TB2
VFD20 VFD10
F20
1 2 3
S1
REC1
T1F1AF1BF1C
GRD20 GRD10
1 The above drawings are to be used for representative purposes only. Components and component layout vary depending upon unit options selected.
Power Panel/Main Control Box w/ VFD/AFD
Power Panel/Main Control Box w/o VFD/AFD
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 83
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Control Box Component Label Diagram 1
1 Note that starting in late 2010, all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options and features.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 84
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Components 1
Schem. Part Part Voltage Sym. Description Number 208V 230V 460V 575V S1 System Switch 001355000 1 1 1 1 Terminal Blocks TB2 Terminal Block Assy., Main Power Ground Block 349930604 1 1 1 1 TB4 Terminal Block Assy., Factory use 349930605 1 1 1 1 Terminal Block, Grey 2 Row 349930621 2 2 2 2
Terminal Block, Green 2 Row 349930627 2 2 2 2
Terminal End Stop, Grey 349930821 2 2 2 2
Terminal End Plate, Grey 349930721 2 2 2 2
TB7 Terminal Block Assy., Convenience Outlet (REC1) Terminal Block, Grey 2 Row 349930621 2 2 2 2
Terminal Block, Green 2 Row 349930627 2 2 2 2
Terminal End Stop, Grey 349930821 2 2 2 2
Terminal End Plate, Grey 349930721 2 2 2 2
Transformer- Main T1 Transformer- Main Control 038253972 1 Transformer- Main Control 038253954 1 1 Transformer- Main Control 038253981 1 Fuse Puller Kit 349955801 1 1 1 Fuse Cover Kit 349955901 1 1 1 Fuses- T1 F1A, B Fuse- T1 Transformer- Primary, 6A 349937125 2 3 Fuse- T1 Transformer- Primary, 5A 349937124 3 3
Fuse- T1 Transformer- Primary, 4A 349937123 3 Fuse- T1 Transformer- Primary, 3A 349937120 2 F1C Fuse- T1 Transformer- Secondary, 7A 349937029 3 3 3 1 Fuse- T1 Transformer- Secondary, 6A 349937027 3 3 3
1 This table lists the most commonly offered Power Panel/Main Control Box components. For components not listed here, contact Daikin Applied with model and serial number information (and vendor p/n information- if available) to ensure that the correct part(s) are identified.
2 Terminal Block assemblies are made up of the components listed. The number AND quantity of parts used varies depending upon unit options selected. Confirm how many of each part(s) are needed BEFORE ordering.
3 Note that EITHER fuse could have been installed. Check the installed part to verify, or for units built 10/10 & Later use the Distributor Tools BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 85
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Components, Continued 1
Fuse- VFD/AFD, Return Fan FB20 Fuse Block 023780232 1 1 1 1 Fuse Puller/Cover 349938227 3 3 3 3 Fuse 2 3 3 3 3 REC1 Receptacle, Ground Fault 039003600 1 1 1 1 GLG1 Ground Lug 349938001 1 1 1 1 Power Block PB1 Power Block 030372705 1 1 1 1 Cover- Power Block 349938301 1 1 1 11 This table lists the most commonly offered Power Panel/Main Control Box components. For components not listed here contact
Daikin Applied with unit model and serial number information and vendor p/n information (if available) to ensure that the required part(s) can be identified.
2 Note that the Fuse rating varies over the production run. Check the installed part to verify, or for units built 10/10 & Later use the Distributor Tools BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Schem. Part Part Voltage Sym. Description Number 208V 230V 460V 575V
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 86
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Disconnect Switch- DS1
Code 08= YY AND Code 23= A, E
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 DS1 Disconnect Switch- Main 1 100A 349935125 1 1 1 1 2 Lug Kit 349956101 1 1 1 1 3 Lug Cover 349905703 1 1 1 1 4 Handle/Mechanism/Shaft/Insulation Assy. 349935521 1 1 1 1
208V
230V
460V
575V
1 100A is the most commonly offered Disconnect Switch size. Check the installed part to verify, or for units built 10/10 & Later use the Distributor Tools BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
1
2
3
4
4
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 87
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 CB1 Circuit Breaker- Main 1 Circuit Breaker, 15A 349936601 1 1 1 1
Circuit Breaker, 30A 349936604 1 1 1 1
Circuit Breaker, 60A 349939609 1 1 1 1
2 Lug Kit 349956101 1 1 1 1 3 Lug Cover 349905703 1 1 1 1 4 Handle/Mechanism/Shaft/Insulation Assy. 349935521 1 1 1 1
208V
230V
460V
575V
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Circuit Breaker CB1 (Code 08= *A)
1
2
3
4
4
1 These are the the most commonly offered Circuit Breaker sizes. Check the installed part to verify, or for units built 10/10 & Later use the Distributor Tools BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 88
3B 3F
1
2
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Diagram & Components 1
1 The diagram and table show all possible parts. Not every part shown is used on every unit/voltage combination. Note that MMPs are only used when no Inverter is supplied.
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934047 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934046 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
208V
230V
460V
575V
1 HP Motor- Code 13 OR 19= E****
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 1 1 2 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934047 1 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
1.5 HP Motor- Code 13 OR 19= F****
208V
230V
460V
575V
3G
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 89
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934047 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
208V
230V
460V
575V
2 HP Motor- Code 13 OR 19= G****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 1
1 The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination. Note that MMPs are only used when no Inverter is supplied.
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
208V
230V
460V
575V
3 HP Motor- Code 13 OR 19= H****
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
208V
230V
460V
575V
5 HP Motor- Code 13 OR 19= J****
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 90
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932321 1 1 Contactor- Supply Fan 349932122 1 Contactor- Supply Fan 349932121 1 3 MMP10 MMP- Supply Fan 349934053 1 1 MMP- Supply Fan 349934051 1 MMP- Supply Fan 349934050 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
208V
230V
460V
575V
7.5 HP Motor- Code 13= K****
Section G- Power Panel/Main Control BoxPower Panel (Code 06= C, G): Supply MMP10 & M10 Fan Contactor, & Return MMP20 & M20 Fan Contactor- Components, Continued 1
Voltage Ref. Schem. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932322 1 1 Contactor- Supply Fan 349932123 1 Contactor- Supply Fan 349932122 1 3 MMP10 MMP- Supply Fan 349934055 1 1 MMP- Supply Fan 349934052 1 MMP- Supply Fan 349934051 1 3B Link 349932922 1 1 1 1 3F Spacer 349906501 1 1 1 1 3G Auxilary- 1 NO/1 NC 349933821 1 1 1 1
208V
230V
460V
575V
10 HP Motor- Code 13= L****
1 The tables show ALL possible parts. Not every part shown is used on every unit/voltage combination. Note that MMPs are only used when no Inverter is supplied.
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 91
Section G- Power Panel/Main Control BoxInverters (VFD/AFD) 1
Motor Horsepower 3
1 1.5 2 3 5 7.5 10
Part Number 099488004 1 1 1 1 1 1 1 1 099488103 1 1 1 1 099488005 1 1 099488104 1 099488006 1 1 099488105 1 099488007 1 1 099488106 1
208V
230V
460V
20
8V
230V
460V
20
8V
230V
460V
20
8V
230V
460V
20
8V
230V
460V
20
8V
230V
460V
20
8V
230V
460V
Code 08= *A: ABB Model ACH550 (8/04 & Later) 1, 2
1 Model ACH401 inverters (VFD/AFDs) used until 8/04 have been discontinued and are no longer available. Replace with the comparable Model ACH550 p/n shown above. Note that repair parts for Model ACH401 inverters are also no longer available. If a part for an ACH401 inverter fails, the entire drive must be replaced. The Keypad Display for Model ACH550 Inverters is p/n 300040924.
2 Quantity listed is for the Supply Air Fan only (Code 06= 6*). If the unit has a Return Fan Inverter (Code 08= 7*) the unit will have a quantity of two Inverters. Note that Inverters are not available for 575V units (Code 04= 37 AND Code 08= YY).
3 Return Air Fans are limited to motors 5 HP and smaller.
Return Air Fan Inverter (VFD/AFD20)
Supply Air Fan Inverter (VFD/AFD10)
Rooftop Units: RDS 708 Vintage "B" Rev. G 07/19 RPL 476526 / Page 92
Section H- Miscellaneous Cabinet ComponentsNotes, Door Latches, Hinge, & Holding Rod
Primary Codes that pertain: None
These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door.
Door Latch Assembly Left-hand Side
Door Holding Rod
11
09
02
11
09
01
44
Door Latch Assembly Right-hand Side
Ref. Part Part No. Description Number 01 Door Latch Assy. Right Hand- 02/02 & Earlier 055516022 02 Door Latch Assy. Left Hand- 02/02 & Earlier 055516021 01 Door Latch Assy. Right Hand- 2/02 & Later 111242202 02 Door Latch Assy. Left Hand- 2/02 & Later 111242201 09 Rivet 039002100 11 Door Latch Screw 039449902 N/S Hinge, Door 032457700 44 Door Holding Rod 33” Section Dimension A = 18.80” 038269305 44 Door Holding Rod 48” Section Dimension A = 27.50” 038269307
A