For the qualified installer ROTEX HPSU compact Solar tank with integrated interior heat pump unit Installation instructions Types HPSU compact 508 HPSU compact 516 Serial number Customer GB Edition 11/2010

Transcript of ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some...

Page 1: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

For the qualified installer

ROTEX HPSU compactSolar tank with integrated interior heat pump unitInstallation instructions

Types

HPSU compact 508

HPSU compact 516

Serial number

Customer

GBEdition 11/2010

OK

<

<

Page 2: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 FA ROTEX HPSU compact - 11/2010

Guarantee and conformity

Guarantee conditionsThe legal guarantee conditions fundamentally apply. Our warranty conditions beyond that can be found online on your sales presentative's webpage.

Declaration of conformity

for the Solar tank with integrated interior heat pump unit (ROTEX HPSU compact).

We, ROTEX Heating Systems GmbH, declare under our sole responsibility that the products

Product Order No. Product Order No.

ROTEX HPSU compact 508 14 15 00 ROTEX HPSU compact 516 14 15 01

comply, in its standard design, with the following European Directives:

2004/108/EC Electromagnetic Compatibility Directive

2006/95/EC EC Low Voltage Directive

Güglingen, 01.06.2010 Dr Eng. Franz Grammling�Managing Director

Page 3: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

List of contents

3FA ROTEX HPSU compact - 11/2010

1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.1 Refer to the manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.2 Warning signs and explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.3 Avoid danger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.4 Proper use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.5 Instructions for operating safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2 Set-up and installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.1 Dimensions and connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.3 Hydraulic connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.4 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.4.1 Installation of cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.4.2 Connection diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.4.3 Connection of exterior heat pump unit RRLQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.4.4 Connection of backup-heater and booster-heater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.4.5 Connection of room thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.4.6 Connection of pulse input, current meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.4.7 Connection of low tariff connection (HT/NT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.4.8 Connection of switching contact (AUX output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.4.9 Connection of ROTEX Solaris installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.4.10 Symbols, key designations, cable colours and complementing instructions to the connection and electrical circuit diagrams . . . 19

2.5 Laying refrigerant lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.6 Pressure test and vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223.1 Initial start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

3.1.1 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223.1.2 Configuration of DIP switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223.1.3 Test run and setting of minimum flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.1.4 Set parameters of main control unit HPR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243.1.5 Set parameters for the additional control unit HPRA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

3.2 Re-commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264.1 Basic data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264.2 Characteristic lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

4.2.1 Sensor characteristic lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284.2.2 Characteristic curves for pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

5 List of keywords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Page 4: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

1 x Safety

4 FA ROTEX HPSU compact - 11/2010

1 Safety1.1 Refer to the manual

This instruction manual is directed at persons who are authorised and who have successfully completed an enabling technical or craft training course, as well as having attended a further educational course recognised by the individual authorities concerned. This, in particular, includes heating technicians and climate control technicians who have experience, as a result of their technical training and their knowledge of the subject, of proper and appropriate installation and maintenance of heating, climate control and cooling installations and heat pumps.

This manual provides all the necessary information for installation, commissioning and maintenance, as well as basic information on operation and settings. The parameters needed for smooth operation are already factory-set. Please see the attached documents for a detailed description of operation and control.

Please read this manual carefully and thoroughly before proceeding with the installation or modification of the heating system.

Relevant documents– ROTEX HPSU compact; the associated operating instructions and the operating manual for the operator.– External unit for ROTEX HPSU compact; the associated installation and operating instructions.– When connecting a ROTEX Solaris solar installation; the associated installation and operating instructions.

The guides are included in the scope of supply for the individual units.

1.2 Warning signs and explanation of symbols

Meaning of the warningsWarnings in this manual are classified according into their severity and probability of occurrence.

DANGER!

Draws attention to imminent danger.

Disregarding this warning can lead to serious injury or death.

WARNING!

Indicates a potentially dangerous situation.

Disregarding this warning can result in serious injury or death.

CAUTION!

Indicates a situation which may cause possible damage.

Disregarding this warning may cause damage to property and the environment.

This symbol identifies user tips and particularly useful information, but not warnings or hazards.

Page 5: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

1 x Safety

5FA ROTEX HPSU compact - 11/2010

Special warning signs

Some types of danger are represented by special symbols:

Order numberNotes related to Order numbers are identified by the cart symbol .

Handling instructions• Handling instructions are shown as a list. Actions of which the sequential order must be maintained are numbered.

� Results of actions are identified with an arrow.

1.3 Avoid danger

The ROTEX HPSU compact is state-of-the-art and is built to meet all recognised technical requirements. However, improper use may result in serious physical injuries or death, as well as property damage. To prevent such risks, install and operate ROTEX HPSU compact only:– as stipulated and in perfect condition,– with an awareness of safety and the hazards involved.

This assumes knowledge and use of the contents of this manual, of the relevant accident prevention regulations as well as the recognised safety-related and occupational health rules.

1.4 Proper use

The ROTEX HPSU compact may only be used as a hot water heating system and a cold water cooling system. The ROTEX HPSU compact must be installed, connected and operated only according to the indications in this manual.

Only use of a suitable external unit approved by ROTEX is permitted. The following combinations are permissible in this respect:

Tab. 1-1 Permissible combinations of ROTEX external units for heat pumps and the ROTEX HPSU compact

Electric current Danger of explosion

Danger of local freezing up Danger of burning or scalding

Health impairing or irritant materials Danger of environmental damage

Prescribed temperature for continuous use

WARNING!

This unit is not intended for use by persons (including children) with impaired physical, sensory or mental faculties or persons with insufficient experience and/or expertise unless supervised by a person responsible for ensuring their safety or are given instruction by this person on how to use the unit.

Internal unit Order No. External unit Order No.

HPSU compact 508 14 15 00

RRLQ006BAV3 14 41 42

RRLQ007BAV3 14 41 43

RRLQ008BAV3 14 41 44

HPSU compact 516 14 15 01

RRLQ011BAW1 14 41 48

RRLQ014BAW1 14 41 49

RRLQ016BAW1 14 41 50

Page 6: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

1 x Safety

6 FA ROTEX HPSU compact - 11/2010

Any other use outside the above-mentioned use is considered as improper. Responsibility for any resulting damage will be borne by the user/owner alone.

Intended use also includes the observance of maintenance and inspection conditions. Replacement parts must at least satisfy the technical requirements defined by the manufacturer. This is the case, for example, with original spare parts.

1.5 Instructions for operating safety

Before working on the hot water heating system and cold water cooling system• Work on the ROTEX HPSU compact (such as setup, servicing, connection and initial start-up) is only to be carried out by

persons who are authorised and who have successfully completed qualifying technical or vocational training and who have taken part in advanced training sessions recognised by the appropriate responsible authorities. This, in particular, includes heating technicians and climate control technicians who have experience, as a result of their technical training and their knowledge of the subject, of proper and appropriate installation and maintenance of heating, climate control and cooling installations and heat pumps.

• Switch off the mains supply before starting any work on the ROTEX HPSU compact and secure it against unintentional switch-on.

• Lead tamper-proof seals must not be damaged or removed.• Make sure that the safety valves comply with the requirements of EN 12828 when connecting on the heating side, and with

the requirements of EN 12897 when connecting on the domestic water side.• Only original ROTEX replacement parts may be used.

Electrical installation• Electrical installations may only be carried out by qualified electrical technicians under observance of the relevant electrical

guidelines and the regulations of the electric utilities company (EVU).• Compare the mains voltage (~230 V, 50 Hz or ~400 V, 50 Hz) indicated on the nameplate with the supply voltage before

connecting to the mains.• Before beginning work on live parts, disconnect them from the power supply (switch off main switch, remove fuse) and

secure against unintentional restart.• Equipment covers and service panels must be replaced as soon as the work is completed.

Working on cooling systems (heat pump)

• Always wear safety goggles and protective gloves.• When working on the refrigerant circuit, ensure that the workplace is well ventilated.• Never carry out work on the refrigerant circuit in closed rooms or work pits.• Do not let refrigerant come into contact with open fire, embers or hot objects.• Never allow refrigerant to escape into the atmosphere (high pressure at the point of the leak).• When removing the service pipes from the filling connections, never hold the connections in the direction of your body.

Residual refrigerant could escape.• Components and spare parts must at least satisfy the technical requirements defined by the manufacturer.

Corrosion protectionIn some regions, corrosive drinking water is supplied by public utility companies that can cause damage through corrosion even in high grade stainless steels. Ask your water utility whether the use of heating components made from stainless steel results in problems with corrosion in your area.

Suitable water treatment may be required.

Equipment installation locationFor safe and fault-free operation, it is necessary that the installation location of the HPSU compact fulfils certain criteria. Related information can be found in chapter 2.

Information on the installation site of other components can be found in the associated documentation supplied with them.

For work on stationary refrigeration systems (heat pumps) and air conditioning systems, proof of expertise is required in the European Community according to the F-Gases Directive (EC) No. 842/2006.

– total overall coolant weight up to 3 kg: expert certificate Category 2– total overall coolant weight in excess of 3 kg: expert certificate Category 1

Page 7: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

1 x Safety

7FA ROTEX HPSU compact - 11/2010

Hydraulics• Create a heating system according to the safety requirements of EN 12828.• For the connection on the heater side, the safety valves must meet the requirements of EN 12828 and must be type-approved.

When a solar energy facility is connected, the temperature of the tank must not exceed 60 °C.• When installing the system, you should therefore fit a scald protection unit (e. g. VTA32, 15 60 15).When using a HPSU heat pump system in a bivalent construction or with solar heating support, a shut-off due to excess pressure may arise due to an excess return temperature on the HPSU.

• To prevent heat spikes, install a return line temperature limiter in the installation.– RLB 300, 14 01 14– RLB 500, 14 01 15

Sanitary connectionWith sanitary connection, you must observe;

• EN 1717 - Protection of drinking water from contamination in drinking water installations and general require-ments for safety equipment for prevention of drinking water contamination by back-flow,

• EN 806 - Technical regulations for drinking water installations (TRWI),• and, in addition, the country-specific legal stipulations.

OperationThe ROTEX HPSU compact:• Do not operate until all installation and connection work is completed.• Only operate with a completely full storage tank (Level indicator) and heating circuit.• Only connect with pressure reducers on the external water supply line.• Operate at a maximum pressure of 3 bar.• Only operate with the specified quantity of refrigerant and the type of refrigerant specified.• Only operate when the cover has been assembled.

The prescribed maintenance intervals must be maintained and the inspection work must be carried out.

Instruct the owner• Before you hand over the ROTEX HPSU compact, explain to the user/owner how to operate and check the system.• Document the handover by filling out the installation and instruction forms together with the owner and sign them.

Documentation• The technical documentation included in the scope of supply is a constituent part of the equipment. It must be stored in such

a way that it can be consulted at any time by the operator or the technicians.

Page 8: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

8 FA ROTEX HPSU compact - 11/2010

2 Set-up and installation

2.1 Dimensions and connections

WARNING!

Cooling systems (heating pumps), climate control systems and heating devices that have been set up and installed incorrectly can both endanger life and health of people and be impaired in their function.

• Work on the HPSU compact (such as setup, servicing, connection and initial start-up) is only to be carried out by persons who are authorised and who have successfully completed qualifying technical or vocational training and who have taken part in advanced training sessions recognised by the relevant responsible authorities. These include in particular certified heating engineers, qualified electricians and HVAC specialists, who because of their professional training and expert knowledge, have experience in the professional installation and maintenance of heating, cooling and air conditioning systems and heat pumps.

1 Cold water2 Hot water3 Heating feed4 Heating return flow5 Solaris feed

6 Connection refrigerant gas line 7 Connection refrigerant fluid line

A FrontB Back

Fig. 2-1 Connections and dimensions HPSU compact (General)

Page 9: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

9FA ROTEX HPSU compact - 11/2010

1 Solaris - flow (1“ swivel nut)2 Cold water supply (1“ male)*3 Hot water (1“ male)*4 Heating flow (1“ male)*5 Heating return flow (1“ male)*6 Circulation pump (storage tank circuit)7 Safety-pressure relief valve (heating circuit) 16 Optional booster-heater (R 11/2“ female)18 Optional backup-heater (R 11/2“ female)20 Fill level indicator (tank water)29 Noise insulation30 Plate heat exchanger (PWT)31 Connection refrigerant fluid line �

HPSU compact 508: CuT, Ø 6.4 mm (1/4"), �HPSU compact 516: CuT, Ø 9.5 mm (3/8")

32 Connection refrigerant gas line�CuT, Ø 15.9 mm (5/8")

33 Filling connection for refrigerant34 Ball cock (heating circuit)35 Combined filling and draining valve (heating circuit)37 Storage tank temperature sensor tDHW1 and tDHW238 Connection diaphragm expansion vessel (MAG)

3UV1 3-way switch valve (hot water/heating)3UVB 3-way switch valve (temperature limiter)HPR Control housing with electr. terminal striptR1 , V1�

Return line and flow sensortR2 Return temperature sensortV1 , tV2

Flow temperature sensorstV, BH1 , tV, BH2

Flow temperature sensors, backup-heater

Fig. 2-2 Connections and dimensions HPSU compact (top of unit)

!

Page 10: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

10 FA ROTEX HPSU compact - 11/2010

1 Solaris - flow (1“ swivel nut)2 Cold water supply (1“ male)*3 Hot water (1“ male)*4 Heating flow (1“ male)*5 Heating return flow (1“ male)*6 Circulation pump (storage tank circuit)7a Recommended accessories: �

Non-return valves (2 pcs.), 16 50 708 Storage tank (double-wall polypropylene sleeve

with PUR rigid foam heat insulation)9 Filling and drain connection (Tr. 32x3 male) with

valve insert(When connecting a ROTEX Solaris solar installation: Solaris - return

10 Connection for equalising pipe (AGL, 16 01 08) or extension set for another heat source (EWS, 16 01 10)

12 Corrugated stainless steel pipe heat exchanger for domestic hot water heating

13 Corrugated stainless steel pipe heat exchanger for heat loading

14 Stainless steel corrugated pipe heat exchanger for heating support

15 Connection for optional booster-heater �(R 11/2“ female)

17 Connection for optional backup-heater �(R 11/2“ female)

19 Solar - flow stratification pipe (for use with connection of optional ROTEX Solaris solar installation)

20 Fill level indicator (water circuit)21 Submersible sensor sleeve for storage tank

temperature sensor tDHW1 and tDHW222 Pressure-free storage tank water23 Solar zone24 Hot water zone25 Safety overflow connection (Tr. 32x3 male)26 Handle27 Type plate28 Protective cover

30 Panel heat exchanger31 Connection refrigerant fluid line �

HPSU compact 508: CuT, Ø 6.4 mm (1/4"), �HPSU compact 516, Ø 9.5 mm (3/8")

32 Connection refrigerant gas line �CuT, Ø 15.9 mm (5/8")

36 Pressure gauge (heating circuit)

3UV1 3-way switch valve (hot water/heating)3UVB 3-way switch valve (temperature limiter)HPR Control housing with electr. terminal stripHPR1 Main controlHPRA1�

Additional controlRPS3 Optional: Solaris control and pump unit

Safety devices

Fig. 2-3 Connections and dimensions HPSU compact (side view and interior)

!

!

Page 11: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

11FA ROTEX HPSU compact - 11/2010

2.2 Installation

• Remove packing and dispose of it in an environment-friendly manner.• Install the HPSU compact at the installation site.

– Recommended clearances (Image 2-4):�From the wall (s1): �200 mm�From the ceiling (X): �1200 mm.

– Transport the HPSU compact carefully, using the handles provided on it.

2.3 Hydraulic connection

Requirement: Optional accessories (e. g. Solaris, backup-, booster-heater) are pre-mounted on the HPSU compact in line with the specifications of the supplied manual.

• Establish hydraulic connections at the HPSU compact.– For the position and dimension of the connections, see section 2.1.

• Carefully lag the hot water pipes to prevent heat loss.– The thermal insulation needs to be at least 20 mm thick to prevent condensation from forming on the surface of the

insulation material.• Connect the pressure relief line to the safety pressure relief valve and the membrane expansion tank as per EN 12828.• Check cold water pressure (maximum 6 bar).

� If a higher pressure is present in the domestic water pipe, a pressure reducer will need to be installed.

• Connect drainage hose to the connection on the safety overflow (Image 2-3, item 25).– Use transparent drain hose (draining water must be visible).– Connect the drain hose to an adequately dimensioned waste water installation.– Drain should not be lockable.

Optional backup-, booster-heater (BUH/BOH):When installing a backup-, booster-heater, it must be installed in the HPSU compact before the final installation and filling.

A separate manual containing instructions about installation and operation is included with these components.

Fig. 2-4 Installation HPSU compact

CAUTION!

If the HPSU compact is connected to a heating system with steel pipes, radiators or non-diffusion-proof floor heating pipes, slurry and swarf could enter the hot water storage tank and cause blockages, local overheating or corrosion.

• Flush the feed pipes before filling the heat exchanger.• Rinse out the heat distribution network (in the existing heating system).• Install dirt filter in the heating return line (e. g. SFR 28 15 60 11).

Page 12: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

12 FA ROTEX HPSU compact - 11/2010

• Open the cold water connection and fill the potable water heat exchanger.• Fill buffer tank above the fill and discharge connection (Image 2-3, Pos. 9) until the water emerges from the safety overflow

(Image 2-3, Pos. 9).

2.4 Electrical connection

2.4.1 Installation of cables

WARNING!

Touching live parts can result in an electric shock and lead to potentially fatal injuries and burns.

• Before beginning work on live parts, disconnect them from the power supply (switch off fuse, main switch) and secure against unintentional restart.

• The electrical connection and working on the electrical components should only be performed by electrical engineers in compliance with valid standards and guidelines as well as the specifications of the energy supply company.

• The equipment covers and maintenance opening covers must be re-fitted immediately after completion of the work.

CAUTION!

Increased temperatures may arise in the control housing of HPSU compact during operation. This can result in currently-carrying wires from reaching higher temperatures during operation due to self-heating. For this reason, these lines must have a temperature for continuous use of 90 °C.

• For the following connections, only use cables with a temperature for continuous use of �90 °C:– Exterior heat pump unit– Backup-heater (optional)– Booster-heater (optional)

Fig. 2-5 1. Remove the cover. Fig. 2-6 2. Remove the right housing cover. Fig. 2-7 3. Unlock front blank.

Fig. 2-8 4. Open front blank and bring to mounting position.

Fig. 2-9 5. Install cabling in the control (strain relief 1) and set up electrical connections (see section 2.4.2).

Fig. 2-10 6. Install cabling in right housing cover (strain relief 2).

Page 13: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

13FA ROTEX HPSU compact - 11/2010

2.4.2 Connection diagrams

Overall connection diagram

Fig. 2-11 7. Attach right housing cover. Fig. 2-12 8. Fix cabling to the storage tank (strain relief 3).

Fig. 2-13 Overall connection diagram

Page 14: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

14 FA ROTEX HPSU compact - 11/2010

Position of the circuit boards

Connection assignment, circuit board A1PThe A1P circuit board comes pre-connected to the unit. No assembly or connection work is necessary on the A1P circuit board!

A1P Circuit board (under XR1P)A4P Solaris circuit board (accessories)X1 Terminal stripXR1P Circuit board

Fig. 2-14 Overview, circuit boards of control unit

Fig. 2-15 Circuit board A1P

A4P

A1P

XR1P

X1

21

21

11

11

11

1 1 1 1

A1P

X4(X

RP1)

(XRP

1)X3X3

(XRP

1)(X

RP1)

X2X2(X

RP1)

(XRP

1)FU1 (250V T 3,15A)

X13A

SS2

SS1on

onoff

X17A

X21A

X14A

X16A

X20A

X15A X19A X11A X12AX3A

X4A

X10A

X18A

X40A

X5AX6AX7AX8AX9AX33A

X1A

X61A

X60A

Page 15: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

15FA ROTEX HPSU compact - 11/2010

Connection assignment, XR1P circuit board

Fig. 2-16 Circuit board XR1P Mains voltage 230 V or 400 V, 50 Hz (1= Connection diagram in this manual(2= Connection diagram in the manual for the part)

1

1 1 1

12

20

1

1

1

612

12

26

1

57

3UV1 L

3UV1 N

3UV1 L‘

PEN

L3U

VB L3U

VB L‘

12

12

12

3UVB N

1 2 1 2 1 2

PWM

A4P

3UVB

P

Y3YC

AB

M

AB3U

V1

AB

M

AB

A1P

A1P

A1P

A1P

A1P

A1P

XS2

X2

X1

1

11

5

1

1 4

1 2 4

1

63

10

XR1P

X5

(1(1

(1(1

(1

(2

(2

(1(2

(1(1

(1

X6

X4

X7XS

6XS

5XS

4

XS6

XS5

XS4

t V1

t (FLS

100)

R1+

V1

t V, B

H1t DH

W1

XS1

F1 (2

50V

T 2A

)

K5

K6

K10

K8

K9

K1

K11

K12

K2K3

K4

K7

XS8

XS7M1X13AX12A

X3

X11A XS3

NRT N

RT CBO N

BO L1BU N

BU L3BU L2

BU L1BU T1BI

V LRT L

RT HBO N

BO T1BU N

BU NBU N

BU NBU NBU T3

BU T2

PEPE

PE

2NN

N

3CO

M1L

BPH L

PEPE

PE

AUX 2

BSK 2

AUX 1

BSK 1

AUX 3

BSK 3

EVU 2

IN2

GND

EVU 1

IN1

GND

IN3

PWM

GND

PEPE

PEPE

PEPE

PEPE

12039

193858

BIV

BOH

RRLQ

RTBI

VBP

HAU

XBS

KIN

EVU

BUH

HPRA

1

Wh

RPS3

BIV

RTHT

/NT

RRLQ

K

≤25

V AC

≤60

V DC

T1A / 2

50V

XBO1

Boos

ter-H

.Ba

ckup

-H.

Power

XBH1

Power

Page 16: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

16 FA ROTEX HPSU compact - 11/2010

2.4.3 Connection of exterior heat pump unit RRLQ

2.4.4 Connection of backup-heater and booster-heater

A separate manual containing instructions about installation and operation is included with this component.

Fig. 2-17 Connection of exterior heat pump unit

A separate manual containing instructions about installation and operation is included with this component.

2N N N

3COM

1L BPHL

PE PE PE12

X1 (XR1P)

X1M

RRLQHPSU compact

3

E1H

F8U

F9U

X1Y2X1Y12 1

Fig. 2-18 Connection, optional booster-, backup-heater

Page 17: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

17FA ROTEX HPSU compact - 11/2010

2.4.5 Connection of room thermostat

2.4.6 Connection of pulse input, current meter

A separate manual containing instructions about installation and operation is included with this component.

Installation without room thermostat:The cable bridge- mounted on-site - is recommended by ROTEX as otherwise problems may arise due to the cyclical circulation pump during heating operation. The DIP switch 3 (see Tab. 3-1, Chapter 3 "Start-up") must be set to "ON".

The absence of a summer switch-off on the circulation pump can be compensated for by manually switching off heating in the summer (key ) when a cable bridge is mounted.

Fig. 2-19 Connection without room thermostat*

* The cable bridge must be installed on-site before start-up.

Fig. 2-20 Connection with room thermostat cable-connected

(1 In pure heating applications, the "C" terminal connec-tions remain free for the cooling function.

Fig. 2-21 Connection with radio-controlled room thermostat

(1 In pure heating applications, the "C" terminal connec-tions remain free for the cooling function.

Fig. 2-22 Connection pulse input current meter (* alternative connection)

RTN

RTC

RTL

RTH

PE PE9

X1 (XR1P)

HPSU compact

RTN

RTC

RTL

RTH

PE PEX1M

9

X1 (XR1P)

HPSU compact Rotex RKRTW

H com C(1

RTN

RTC

RTL

RTH

PE PE

X2M

X1M

9

X1 (XR1P)

HPSU compact Rotex RKRTR

H C Lcom N(1

Vmax: 12V / Imax. 2mA

Vmax: 12VImax. 2mA

IN2 GND

IN1 GND

IN3 GND

IN2 GND

IN3 GND17

IN2 GND

IN3 GND17

IN1 GND

X1 (XR1P)

HPSU compact

X1 (XR1P)*

HPSU compact

Page 18: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

18 FA ROTEX HPSU compact - 11/2010

2.4.7 Connection of low tariff connection (HT/NT)

2.4.8 Connection of switching contact (AUX output)

2.4.9 Connection of ROTEX Solaris installation

Fig. 2-23 Connection HT/NT contact

Fig. 2-24 Connection switching contact (AUX output)

Fig. 2-25 Connection BSK contact for optional Solaris installation

1

2

3

EVU2

EVU1

19

1 1

22

4 4 4 43 33 3

L N L N

[D-01] = 1 [D-01] = 2

1 1

22

4 4 4 43 33 3

1 1

22

3 33 3

RRLQ*

4 43 3

S2S

S2S

S2S

S2S

S2S

S2S

X1 (XR1P)HPSU compact

L- L+

K AUX2

AUX1

AUX3

16

≤25V AC≤60V DC

X1 (XR1P)

HPSU compact

BRN

GRY

BLK

RPS3

BSK2

BSK1

BSK315

X1 (XR1P)

HPSU compact A separate manual containing instructions about installation and operation is included with this component.

The required burner block contact cable is included with the SOL-PAC ( 14 05 27).

Page 19: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

19FA ROTEX HPSU compact - 11/2010

2.4.10 Symbols, key designations, cable colours and complementing instructions to the connection and electrical circuit diagrams

Explanation Explanation

Cable colours (two colour cables are given as follows: Colour 1/Colour 2)

BLU Blue ORG Orange

BLK Black PNK Pink

BRN Brown RED Red

GRN Green VIO Violet

GRY Grey WHT White

YLW Yellow

Symbols

Safety earthingExternal cabling (number of individual cores and the mains voltage are partially quoted.)

Low external voltage earthing Pushbutton

Connection terminal DIP switch

Plug connection Optional component

Terminal rail Plug and socket connection

2-core cabling (non-screened) 3-core cabling (non-screened)

4-core cabling (non-screened) 5-core cabling (non-screened)

6-core cabling (non-screened) Screened cabling (e.g. 3-core)

Tab. 2-1 Cable colours and symbol explanations for connection and circuit diagrams

Key names

Short designation Explanation Short designation Explanation

3UV1 3-way switch valve heating/hot water tV, BUH1 Pre-temperature sensor 1 (for backup-heater)

3UVB 3-way switch valve temperature limiter tV, BUH2 Pre-temperature sensor (for backup-heater)

A1P Connection board V1 Flow sensor

A4P Connection board SOL-PAC X1 Terminal strip mains connection

AUX Switching contact X2 Plug connection, internal 1

BUH Backup-heater X3 Plug connection, internal 2

BIV BIV- Control X4 Plug connection internal 3

BOH Booster-heater X5 Plug connection ribbon cable 1 HPRA1

BPH Bottom-plate-heater X6 Plug connection ribbon cable 2 HPRA1

BSK Burner block contact (Solaris) X7 Plug connection, N bridge

F1 Fuse 250 V T 2A X1BO Plug connection booster-heater (BOH)

F8U Fuse 1 for bottom-plate-heater X1BH Plug connection backup-heater (BUH)

F9U Fuse 2 for bottom-plate-heater X1M Terminal rail

E1H Additional heating for exterior heat pump unit X4A Plug connection flowswitch

FLS100 FlowSensor X5A Plug connection flow temperature sensor tV2

Page 20: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

20 FA ROTEX HPSU compact - 11/2010

HPR1 Main control unit tV, BH2 Pre-temperature sensor backup-heater 2

HPRA1 Additional control unit X6A Plug connection flow temperature sensor tV, BUH2

K Switching contact (safety-low voltage) X7APlug connection temperature sensor�(fluid-side refrigerant) tL2

K1 Relay booster-heater (BOH) X8A Plug connection return line temperature sensor tR2

K2 Relay backup-heater (BUH) 1 X9A Plug connection tank temperature sensor tDHW2

K3 Relay backup-heater (BUH) 2 X11A Plug connection BIV control

K4 Relay backup-heater (BUH) 3 X12A Plug connection BIV control

K5 Relay circulation pump P X13A Plug connection BIV control

K6 Relay flowswitch X14APlug connection additional heating HPSU Exterior heat pump unit

K7 Relay STB monitoring booster-heater (BOH) X15A Plug connection H1P

K8 Relay 1 room thermostat (reversal) X16A Plug connection 3UV1

K9 Relay 2 room thermostat (control) X17A Plug connection room thermostat

K10 Relay AUX output X19A Plug connection mains voltage

K11 Relay 3UVB (ON) X20A Plug connection 3UVB

K12 Relay 3UVB (OFF) X21A Plug connection STB booster-heater (BOH)

P Circulation pump X40A Plug connection HT/NT contact EVU

RPS3 Control and pump unit XR1P Circuit board

RT Room thermostat XS1 Plug connection 3UV1/3UVB

RRLQ Exterior heat pump unit XS2 Plug connection circulation pump P

tDHW1 Tank temperature sensor 1 XS3 Plug connection FLS100

tDHW2 Tank temperature sensor 2 XS4 Plug connection flow temperature sensor 1 tV1

tR1 Return line temperature sensor 1 (FLS100) XS5 Plug connection flow temperature sensor tV, BUH1

tR2 Return line temperature sensor 2 XS6 Plug connection tank temperature sensor tDHW1

tV1 Flow temperature sensor 1 XS7 Plug connection PWM (not in use)

tV2 Flow temperature sensor 2 XS8 Plug connection SolPac C (A4P)

tV, BH1 Flow temperature sensor backup-heater 1 V1 Flow sensor

Tab. 2-2 Key names for connection and circuit diagrams

Key names

Short designation Explanation Short designation Explanation

Page 21: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

2 x Set-up and installation

21FA ROTEX HPSU compact - 11/2010

2.5 Laying refrigerant lines

2.6 Pressure test and vacuum

• Perform pressure test with Nitrogen.– Use Nitrogen 4.0 or higher.– Maximum 40 bar.

• After leak search is complete, completely drain.• Vacuum lines.

– Pressure to be reached 1 mbar absolute.– Time: minimum 1 h.

• Check whether additional refrigerant is needed for primer filling, fill where necessary.• Open stop valve on exterior unit completely until the stop. Tighten loosely.• Reassemble valve caps.• Check whether storage tank sensor is 80 cm deep.• For bivalent installations or in connection with the ROTEX Solaris installation: �

Check whether a return line temperature limiter (RLB) was installed.

• Check whether oil raise arc necessary.– Required when HPSU compact not installed on same level as external unit.– An oil raise arc must be installed for every 10 m of height difference �

(Image 2-26, H = distance from one oil raise arc to another).– Oil raise arc only required in the gas line.

• Install lines with bending unit and an adequate clearance to electrical lines.

• Only solder with light nitrogen flow (hard soldering only).• Do not apply insulation to joins until after start-up (for purposes of

leakage search).• Establish flange connections and connect to the units.

A Exterior heat pump unit (RRLQ)B HPSU compactC Gas lineD Liquid lineE Oil raise arcH Height to the 1st oil trap (10 m)

Fig. 2-26 Oil raise arc refrigerant line

The RLB is designed to mix the flow when the heating return line exceeds 55 °C. If the return line temperature continues to rise, the RLB will shut off the heating return line completely and the heat pump runs along a short circuit between the flow and return flow.

The RLB is needed in all installations in which the return flow can exceed 55 °C (Solar, second heat generator,...).

– RLB 300 for HPSU compact 6-8 kW: 14 01 14– RLB 500 for HPSU compact 11-16 kW: 14 01 15

Page 22: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

3 x Start-up

22 FA ROTEX HPSU compact - 11/2010

3 Start-up3.1 Initial start-up

After the ROTEX HPSU compact was installed and connected completely, it will need to be undergo a one-time adaptation to the installation environment to be carried out by technical personnel (Configuration).

After this configuration is complete, the installation is ready for operation and the operator can make additional custom configurations on it.

Setting up optional components such as a room thermostat or the ROTEX Solaris installation is carried out on the particular component.

3.1.1 Requirements

– The ROTEX HPSU compact is fully connected.– The heating and hot water system are filled and charged with the right pressure.– The storage tank is filled to the overflow point.– The heating system's control valves are open.– The refrigerant system is dehumidified and filled with the specified amount of refrigerant.– All electrical connections have been made in accordance with the Installation chapter.– Optional accessories have been mounted on and connected up.

3.1.2 Configuration of DIP switches

Tab. 3-1 DIP Switch Settings (* = factory setting)

WARNING!

To make changes to the DIP switch settings, the installation must first be disconnected from the power supply.

� Non compliance may cause damage to the HPSU compact.

• Check the DIP switch setting on the A1P circuit board of the HPSU compact, adjust where necessary (see Tab. 3-1).

Fig. 3-1 Factory setting SS2

DIP switch No. Designation Setting

SS2

1 Do not change. – –*

2 Domestic hot water generation ON* OFF

3 Room thermostat/pump in continuous operation ON OFF*

4 Do not change. – –*

DIP switch settings are not recognised until a brief interruption to the power supply.

SS2

on1

2 3

4of

f

Page 23: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

3 x Start-up

23FA ROTEX HPSU compact - 11/2010

3.1.3 Test run and setting of minimum flow

• Set pump level 3 of circulation pump of HPSU compact (Image 2-2, Pos. 6).• Start the system by pressing the key on the main control unit (HPR1).• Wait for the start phase.

� The number "88" is displayed for approx. 30 s during the start phase on the display of the main control unit (HPR1).

� The system starts an automatic test run that lasts approx. 30 min.�During this test run, nothing particular is shown on the Display.

� After a successful automatic test run, the system starts normal operation.

• Check minimum flow when heating circuit closed and bypass valve configured:– Minimum flow 6-8 kW HPSU compact (Image 4-3): >12 l/min– Minimum flow 11-16 kW HPSU compact (Image 4-4): >15 l/min

It is important that the water temperature does not fall below 10 °C during the test run. Otherwise the frost protection switch could be activated and the test run would not be completed.

Only when backup-heater (BUH) is installed:If the water temperature falls below 10 °C, the key must be repeatedly pressed until the symbol is displayed. This switches on the backup-heater (BUH) during the automatic test run and the water temperatures is kept above 10 °C.

If the installation has already been put into operation, the test run can also be started manually.

• Start the system by pressing the key on the main control unit (HPR1).• Press the key 4x in succession (also refer to the instruction manual).

1 Main control (HPR1)2 Key "ON / OFF"3 Operating Display LED4 Additional Control Unit (HPRA1)

5 Key +6 Key -7 Key OK8 Pressure gauge (system pressure, heating circuit)

Fig. 3-2 Main display and operating elements

If the minimum flow is too low, an error message may appear and the heating system may shut down.

If the minimum flow is not sufficient at the highest pump level:• Check whether the highest manually adjustable pump level (III) on the circulation pump has been selected

(refer also to Image 4-3 and Image 4-4).• If pump level III is not sufficient, a low loss header will have to be installed with an additional circulation

pump (customer side).

Page 24: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

3 x Start-up

24 FA ROTEX HPSU compact - 11/2010

3.1.4 Set parameters of main control unit HPR1

• Configure main control unit HPR1 of HPSU compact as per installation requirement.– Switch off the legionellic system (if not required).– For setting of installation parameters, see instruction manual.

• Enter settings in the parameter table of the instruction manual.

3.1.5 Set parameters for the additional control unit HPRA1

To set the set-up parameters, login for the heating specialist must be released in the additional control unit HPRA1 (factory setting).

If this is not the case, please contact ROTEX After Sales.

• Enter the password for the specialist.

• Set the set-up parameters (see Instruction manual > chapter Parameter settings >Set-up Parameters for Additional Control).

• Set the correction values (see Instruction manual > chapter Parameter settings >Correction Values for Additional Control).

• Instruct operator, create a set-up log, and complete the operating manual.

Fig. 3-3 Login heating specialist

Fig. 3-4 Enter set-up parameters

Fig. 3-5 Enter Correction Value Level

Page 25: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

3 x Start-up

25FA ROTEX HPSU compact - 11/2010

3.2 Re-commissioning

1. Check the cold water connection and, where necessary, fill the potable water heat exchanger.

2. Check fill level in the buffer tank and where necessary fill using the fill and discharge connection (Image 2-3, Pos. 9) until the water emerges from the safety overflow (Image 2-3, Pos. 9).

3. Start the system by pressing the key on the main control unit (HPR1).

4. Wait for the start phase.

5. After the start phase has completed, in heating mode, evacuate the heating system, check the installation pressure and adjust where necessary (max. 3 bar).

6. Carry out a visual inspection for leaks on all joints internally. Seal any leaks that occur in a professional manner.

7. If a ROTEX Solaris installation is connected, put this into operation in accordance with the supplied manual. After switching on the ROTEX Solaris installation, check the fill level in the buffer tank again.

CAUTION!

Setting up in frosty conditions can result in damage to the entire heating system.• Only set up at temperatures below 0 °C when a water temperature of at least 5 °C can be guaranteed in

the hydraulic system and storage tank.ROTEX recommends not operating the installation in extremely frosty conditions.

Page 26: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

4 x Technical data

26 FA ROTEX HPSU compact - 11/2010

4 Technical data4.1 Basic data

Unit HPSU compact 508 HPSU compact 516

Can be used with Exterior heat pump unitRRLQ006BAV3, RRLQ007BAV3,

RRLQ008BAV3RRLQ011BAW1, RRLQ014BAW1,

RRLQ016BAW1

Dimensions and weights

Dimensions (H x W x D) cm 181 x 79 x 79 181 x 79 x 79

Empty weight kg 124 126

Main components

Water �circulation pump

Type Grundfos ALPHA2 L 15-60 CES87 Grundfos ALPHA2 L 15-60 CES87

Speed rates 3 2

Voltage V 230 230

Frequency Hz 50 50

Protection type IP 42 IP 42

Power consumption A 0.38 0.38

Nominal output maximum W 45 45

Water �heat exchanger

Type Brazed metal plate Brazed metal plate

Number 1 1

Volume 0.67 1.01

Minimum flow quantity l/min 12 16

Maximum flow quantity l/min 32 58

Flow quantity heating (at THP=7 °C, TWW=35 °C, DT=5 °C)

l/min 16.51) / 19.62) / 24.13) 32.14) / 43.55) / 45.96)

Flow quantity cooling (at THP=7 °C, TWW=35 °C, DT=5 °C)

l/min 14.71) / 16.82) / 17.43) 28.74) / 35.85) / 37.66)

Insulation Polyurethane foam Polyurethane foam

Storage tank

Total storage capacity litres 500 500

Maximum permissible storage water temperature °C 85 85

Heat consumption at stand-by and at 60 °C kWh/24h 1.4 1.4

Domestic hot water (stainless steel 1.4404)

Potable water capacity litres 29 29

Maximum operating pressure bar 6 6

Domestic water heat exchanger �surface

m2 6 6

Average specific thermal output W/K 2900 2900

Storage tank charging heat exchanger (stainless steel 1.4404)

Water capacity heat exchanger litres 12.6 20.7

Heat exchanger surface area m2 2.5 4.4

Average specific thermal output W/K 1200 2090

Solar heating backup (stainless steel 1.4404)

Water capacity heat exchanger litres 8.6 8.6

Heat exchanger surface area m2 1.8 1.8

Average specific thermal output W/K 870 870

Page 27: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

4 x Technical data

27FA ROTEX HPSU compact - 11/2010

Heat technics power data

Domestic hot water volume without reheat at a tapping rate (8 l/min /12 l/min)

(TKW = 10 °C/TWW = 40 °C/TSP = 50 °C)

l/min 338 / 272 338 / 272

Domestic hot water volume without reheat at a tapping rate (8 l/min /12 l/min)

(TKW = 10 °C/TWW = 40 °C/TSP = 60 °C)

l/min 527 / 468 527 / 468

Domestic hot water volume without reheat at a tapping rate (8 l/min /12 l/min)

(TKW = 10 °C/TWW = 40 °C/TSP = 65 °C)

l/min 614 / 560 614 / 560

Reheating time (Wh) with a draw-off quantity:

l/min140 l = 5820 Wh (Ø bathtub �draw-off quantity)

45 25

90 l = 3660 Wh (Ø shower draw-off quantity)

30 17

Pipeline connectionsCold and hot water inches 1" male 1" male

Heating feed and return flow inches 1" female 1" female

Refrigerant circuit

Number of circuits 1 1

Pipeline connections

Number 2 2

Liquid lineType inches Flanged connection Flanged connection

External diameter inches 1/4" male 3/8" male

Gas linesType Flanged connection Flanged connection

External diameter inches 5/8" male 5/8" male

Operating data

Operating range

Room heatingHeating

(min./max.)°C -20 to 25 -20 to 35

Cooling (min./max.) °C 10 to 43 10 to 46

Water �heating

Heating (min./max.)

°C 15 to 50 15 to 55

Cooling (min./max.) °C 5 to 22 5 to 22

Noise level 7) Audibility dBA 28 28

Acoustic pressure dBA 42 �

Unit HPSU compact 508 HPSU compact 516

Page 28: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

4 x Technical data

28 FA ROTEX HPSU compact - 11/2010

4.2 Characteristic lines

4.2.1 Sensor characteristic lines

Electrical data:

Voltage�supply

Phases 1 1

Voltage V 230 230

Voltage range V Voltage ±10% Voltage ±10%

Frequency Hz 50 50

Connections

Mains connection 3G 3G

For Exterior heat pump unit 4G 4G

Mains connec-tion for optional additional heating units

Booster-heater (BOH)

3G 3G

Backup-heater (BUH)

4G 4G

Safety devices Fuses and contactors

Order number 14 15 00 14 15 01

Tab. 4-1 Basic data HPSU compact

1) In connection with the exterior heat pump unit RRLQ006BAV32) In connection with the exterior heat pump unit RRLQ007BAV33) In connection with the exterior heat pump unit RRLQ008BAV3

4) In connection with the exterior heat pump unit RRLQ011BAW15) In connection with the exterior heat pump unit RRLQ014BAW16) In connection with the exterior heat pump unit RRLQ016BAW17) At a reference clearance of 1 m.

Unit HPSU compact 508 HPSU compact 516

Temperature sensorMeasured temperature in °C-20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120Sensor resistance in kOhm according to standard or manufacturer's indications

TDHW1, TDHW2 NTC 4783.0 1414.5 811.5 480.6 293.2 183.8 118.2 77.7 52.3 35.8 25.1 17.8 12.9 9.5 7.1TV1, TV2, TV, BH1, TV, BH2

NTC 197.80 120.00 65.84 39.91 24.95 16.04 10.58 7.14 4.77 3.19 2.36 1.74 1.33 1.07 0.84

Flow sensor (flow/temperature)

FLS100

V1

Measured flow in l/min0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0Sensor output voltage in V

(0.36 - 3.5 V) 0.36 0.67 0.99 1.30 1.62 1.93 2.24 2.56 2.87 3.19 3.50

tR1

Measured temperature in °C0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0Sensor output voltage in V

(0.50 - 3.5 V) 0.50 0.80 1.10 1.40 1.70 2.00 2.30 2.60 2.90 3.20 3.50

Tab. 4-2 Sensor Table HPSU compact

Page 29: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

4 x Technical data

29FA ROTEX HPSU compact - 11/2010

RS Sensor resistance (NTC)t TemperaturetDHW1, tDHW2

Tank temperature sensor

tR2 Return temperature sensortV1 , tV2 Flow temperature sensortV, BH1 , tV, BH2

Flow temperature sensors, backup-heater

Fig. 4-1 Resistance characteristics of the NTC temperature sensorHPSU compact

1 Voltage output temperature2 Voltage output flow3 Earth (0 V)4 Supply voltage (+5 V)L Flow rate

t TemperaturetR1 Return line temperatureU Sensor output voltageV1 Flow sensorXS3 Plug connection (V1+tR1) an XR1P

Fig. 4-2 Temperature and flow characteristics of the flow sensor (FLS100) HPSU compact

Page 30: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

4 x Technical data

30 FA ROTEX HPSU compact - 11/2010

4.2.2 Characteristic curves for pumps

I - III Fixed set performance levels of the circulation pumpa - d Modular controlled performance levels of circulation pump

�PR Remaining pumping height circulation pump (in mbar)mH Flow heating network (in l/h)

Fig. 4-3 Remaining pumping height of circulation pump HPSU compact 6-8 kW with auxiliary heater heat exchanger

I - III Fixed set performance levels of the circulation pumpa - d Modular controlled performance levels of circulation pump

�PR Remaining pumping height circulation pump (in mbar)mH Flow heating network (in l/h)

Fig. 4-4 Remaining pumping height of circulation pump HPSU compact 11-16 kW with auxiliary heater heat exchanger

Page 31: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

5 x List of keywords

31FA ROTEX HPSU compact - 11/2010

5 List of keywordsBBackup-heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11, 12, 23

Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Bivalent installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Booster-heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11, 12

Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9C

Characteristic curves for pumps . . . . . . . . . . . . . . . . . . . . . . . . . 30Circuit boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Convection brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Corrosion protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

DDIP switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Dirt filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

EElectrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Backup-heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Booster-heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Connection diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Exterior heat pump unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Important information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Installation of cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Low tariff connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Pulse input, current meter . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Room thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Solaris solar installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Switching contact (AUX output) . . . . . . . . . . . . . . . . . . . . . . 18Symbols, abbreviations, cable colours . . . . . . . . . . . . . . . . . . 19

Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Exterior heat pump unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16External unit for heat pump

Permissible combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5H

Housing installation room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Hydraulic connection

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8, 9Important information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

IInitial start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

LLaying refrigerant lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

MMinimum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

OOil rise arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Operating safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

PParameters

Additional control unit HPRA1 . . . . . . . . . . . . . . . . . . . . . . . . 24Main control unit HPR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Pressure test and vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Pump level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

RRe-commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Relevant documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Return line temperature limiter (RLB) . . . . . . . . . . . . . . . . . . . . . . 21

SSanitary connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Sensor characteristic lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Solaris solar installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11, 18

TTechnical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Basic data HPSU compact . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Characteristic curves for pumps . . . . . . . . . . . . . . . . . . . . . . . 30Sensor characteristic lines . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Temperature for continuous use . . . . . . . . . . . . . . . . . . . . . . . . . 12Test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

WWarranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Page 32: ROTEX HPSU compact€¦ · 1 x Safety FA ROTEX HPSU compact - 11/2010 5 Special warning signs Some types of danger are represented by special symbols: Order number Notes related to

FA ROTEX HPSU compact - 11/2010

x

008.

1406

444_

03 ·

Erro

rs a

nd te

chni

cal c

hang

es e

xcep

ted

· Orig

inal

ver

sion

· 008

.140

6449

_02

· 11/

2010

· in

Ger

man

· � R

OTEX