ROT Rotating incinerator with a patented ”near to zero” emission filter
description
Transcript of ROT Rotating incinerator with a patented ”near to zero” emission filter
ROTRotating incinerator with a patented
”near to zero” emission filter
All data within this presentation is according to the European norms 2000/76/CEE and the future emission limits (2012).
Total Waste TreatmentTechnology ROT
Type of furnace
CC-ROT (counter current)
• the waste is moving downwards in the opposite direction of the furnace hot-gas
Total Waste TreatmentTechnology ROT
Type of waste
• All types of waste– very low calory waste (sludge), – low calory waste (municipal waste, garbage)– high calory waste (hospital waste, industrial waste)
Total Waste TreatmentTechnology ROT
Loading system
• collected and transported to location by trucks • bunker bridge-crane • municipal bulk refuse is loaded automatically • Manual loading is always possible • upper accumulation hopper (trash container)
Total Waste TreatmentTechnology ROT
Furnace & combustion system
Rotating pyrolitic furnace• 1st stage
– Starved air condition– Sterile inert ash and a pyrolitic gas– Sufficiently slow– Cool water injection– Maintaining ashes to 850°-900°– Ash varies around 3%– Fully automated burner– Slight negative pressure
Total Waste TreatmentTechnology ROT
Furnace & combustion system
• Post combustor or “After burner”– Gasses mixed with fresh combustion air– Completely refractory lined (resistent to heat)– Auxiliary burners – Electric interlock– Heated by the pyrolitic combustible gas– Temperature 950° - 1100°– Large manholes & sight glass– Secundary air fan V02 (oxygen)– System control logic
Total Waste TreatmentTechnology ROT
Chimney ..............
• Natural Drift Chimney– Mounted directly over the top of the post combustion chamber top
(25m top)– Used during the heat-up phase and in case of an emergency boiler
emergency shutdown
• Forced Draft Chimney– Forced evacuation of the cleaned flue gas into the atmosphere
(minimum 30m height)
Total Waste TreatmentTechnology ROT
High pressure boiler & heat recuperation system
• needed to cool down the flue gas temperature• used to produce electric energy and heat
• It consists of a high pressure, high temperature boiler
Total Waste TreatmentTechnology ROT
Total Waste TreatmentTechnology ROT
Flue gas standard dry cleaning system (AFS)
• No liquid discharge• To render the emissions to comply fully with European
standards.• Optional: Retrofit dry Super Depuration patented system
– This reduces substantially the emission levels below the limits of the EEC norms.
Total Waste TreatmentTechnology ROT
Supply
• Included– The project (design)
• Excluded– Buildings
– Materials (unless stated differently in the contract)
Total Waste TreatmentTechnology ROT
Total Waste TreatmentTechnology ROT
Total Waste TreatmentTechnology ROT
Total Waste TreatmentTechnology ROT
Summary
• Complete incineration (99,99%)• Complete ash inertisation
– removing toxics & physical binding
• Minimum ash quantity (3%)• Great loading flexibility• Precise combustion control• Low working cost• Very high economical profit
– electric energy & heat
• Long duration of plant
Total Waste TreatmentTechnology ROT
Questions ?