RFID AC SWITCH Final Presentation April 24, 2008.
-
Upload
victoria-chandler -
Category
Documents
-
view
219 -
download
0
Transcript of RFID AC SWITCH Final Presentation April 24, 2008.
![Page 1: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/1.jpg)
RFID AC SWITCH
Final Presentation
April 24, 2008
![Page 2: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/2.jpg)
Team Members
Ricardo CalderonElectrical EngineeringTeam LeaderResearch and DocumentationRFID ReaderPIC ProgrammingWebsite Design
Jonathan StanleyElectrical EngineeringResearch and DocumentationPower SupplyTRIAC ControlWebsite Design
Jerome WalkerComputer EngineeringResearch and DocumentationPIC ProgrammingWebsite Design
Corey TateElectrical EngineeringResearch and DocumentationPower SupplyTRIAC Control
![Page 3: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/3.jpg)
Overview
• Introduction
• Problem
• Solution
• Technical/Practical Constraints
• Design Approach
• Hardware & Software Tests
• Completed Prototype
• Future Work
• Bill of Materials
• Questions
![Page 4: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/4.jpg)
Introduction
• What is RFID?• How can RFID
technology be used?– Inventory Control– Personal Access
![Page 5: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/5.jpg)
Problem
• There are no RFID AC Switches.• Many people are unfamiliar with the capability
RFID Technology.
![Page 6: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/6.jpg)
Solution
• OEM RFID AC Switch• This will give manufacturers a quicker time to
market.
![Page 7: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/7.jpg)
Implementations
• How can the RFID AC Switch be used?
– Light Control
– Security Access
– Outlet Control
![Page 8: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/8.jpg)
Technical Constraints
Name DescriptionSwitching Voltage Must operate at 120 VAC.
Output Current Must have a maximum current of 15 amperes.
Read Distance Must have a read distance of at least 2”.
Authorized Tag Identification
Must read 125kHz tags.
Tag Quantity Must store at least 200 identification tags.
![Page 9: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/9.jpg)
Practical Constraints
Type Name DescriptionManufacturability Size Must have dimensions of at most 4”
in length, 4” in width, and 2” in depth.
Health and Safety Safety Must meet UL (Underwriters Laboratories) guidelines.
![Page 10: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/10.jpg)
Practical Constraints-Size
• RFID AC Switch must have dimensions of at most 4” in length, 4” in width, and 2” in depth
• Why?– Adaptability
![Page 11: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/11.jpg)
Practical Constraints-Safety
• RFID AC Switch must meet UL (Underwriters Laboratories) guidelines
• How to meet these guidelines?– Proper Enclosure– Isolated Connections– Overcurrent Protection
![Page 12: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/12.jpg)
Power Supply
ID-12 RFID READER PIC18F2620
TRIAC
Design Approach
5VDC 5VDC
Tag Information
0 or 5VDC
120 VAC
AC Device
0 or 120VAC
![Page 13: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/13.jpg)
Hardware Tests
• Power Supply
• TRIAC
• RFID Reader
![Page 14: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/14.jpg)
Power Supply Test
Power Supply Circuit Power Supply Circuit Output Voltage 5VDC
![Page 15: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/15.jpg)
TRIAC Test
TRIAC Circuit
0VDC Sent to Gate TRIAC Output 0VAC 0VAC Output Wave
![Page 16: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/16.jpg)
TRIAC Test
5VDC Sent to Gate
120VAC TRIAC Output
120VAC, 60Hz Output Wave
![Page 17: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/17.jpg)
Voltage/Current Tests
Voltage/Current Test Results
Expected
ValueMeasured
Value %Diff
Voltage (VDC) 5 5.042 0.84%
Operating Current (mA) Passive Mode 100 56.5 -43.5%
Operating Current (mA) Active Mode 200 67.1 -66.45%
Output VAC (VAC) 120 122.9 2.36%
![Page 18: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/18.jpg)
RFID Reader Test
LED on when tag Present
ID-12 Reader RFID Tag
RFID Tag Code on Hyperterminal
![Page 19: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/19.jpg)
RFID Reader Test Results
Test Pass/Fail
(Max Distance)2” Distance From Reader FAIL (1.50”)
Reader Inside of Wallet PASS (1.25”)
0.25” Thick Plastic Enclosure PASS (1.25”)
1” Thick Plastic Enclosure PASS (1.00”)
0.25” Metal Enclosure FAIL (NONE)
![Page 20: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/20.jpg)
Other Tests
Constraint Expected Value Actual Value %Diff
Tag Storage Quantity 200 250 25%
Dimmer Modes 3 3 0%
![Page 21: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/21.jpg)
Software Tests
• Format (Erase)• Erase 1 Tag • Write (Store)• Read (Toggle)• Read (Timer 5s)• Read (Timer 10s)• Read (Dimmer)
Good Tag LEDErase Mode
Bad Tag LED
Mode SwitchesReset
Write Mode
Read Mode
![Page 22: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/22.jpg)
Format/Erase Test
![Page 23: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/23.jpg)
Write/Store Tag Test
![Page 24: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/24.jpg)
Erase 1 Tag Test
![Page 25: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/25.jpg)
Toggle - Sunny Day Test
![Page 26: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/26.jpg)
Toggle - Rainy Day Test
![Page 27: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/27.jpg)
Timer 5s & 10s Test
![Page 28: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/28.jpg)
Dimmer Test
![Page 29: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/29.jpg)
Completed Prototype
TRIAC Circuit
AC/DC Circuit
Serial Data Circuit
RFID & Microcontroller Circuit
![Page 30: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/30.jpg)
Dimmer Stages
![Page 31: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/31.jpg)
Future Work
• Meet read range constraint of 2”
• Design PCB to meet size constraint
• Design enclosure to meet safety constraint
• Improve dimmer functionality
![Page 32: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/32.jpg)
Bill of Materials
Device Cost
RFID Reader $29.95
AC/DC Converter $8.50
TRIAC Circuit $2.99
Microcontroller $5.60
Dimmer Circuit $2.66
Serial Input Circuit $2.43
Total Cost: $52.13
![Page 33: RFID AC SWITCH Final Presentation April 24, 2008.](https://reader035.fdocuments.in/reader035/viewer/2022081515/5697bfd51a28abf838cad932/html5/thumbnails/33.jpg)
Questions
Questions??