Research Department www.ces.net
CzechLight testbed
Lada Altmanová
Jan Radil
Stanislav Šíma
Josef Vojtěch
GN2 APM meeting, Prague February 24th, 2005
Prague February 24th, 2005
CzechLight Testbed 2
Research Department APM Meeting www.ces.net
Global Lambda Integrated Facility (GLIF)
• Environment for co-operation:networking, infrastructure, network engineering, system integration, middleware, applications
• GLIF was established by invited participants at the 3rd Global Lambda Grid Workshop, held August 27, 2003 in Reykjavik, Island, www.glif.is
• Dark fibres are often used for Gigabit or 10 Gigabit access to cities and university premises
Prague February 24th, 2005
CzechLight Testbed 3
Research Department APM Meeting www.ces.net
GLIF – World Map December 2004
Prague February 24th, 2005
CzechLight Testbed 4
Research Department APM Meeting www.ces.net
CzechLight connections (to GLIF, to GN2 testbed and to cz premises)
Prague February 24th, 2005
CzechLight Testbed 5
Research Department APM Meeting www.ces.net
Prague February 24th, 2005
CzechLight Testbed 6
Research Department APM Meeting www.ces.net
CzechLight intercity connections Prague – Amsterdam lambda (GLIF facility), first
mile in Prague on dark fibre, OC-192c transmission, grey 1550nm
Prague – Brno, dark fibre, 298.3 km, 66,5 dB, including 257.3 km of G.655 fibre, DWDM OC-192c transmission, NIL test
Prague – Plzen, dark fibre, 159.4 km, 36.7 dB, GE transmission by PCLight EDFA 2in1
Prague February 24th, 2005
CzechLight Testbed 7
Research Department APM Meeting www.ces.net
CzechLight connections in/near Prague Connections of Particle physics workplaces
- Institute of Physics of the Academy of Sciences of the Czech republic, dark fibre, GE transmission- Faculty of Mathematics and Physics of Charles University, dark fibre, GE transmission - Nuclear Physics Institute of the Academy of Sciences of the Czech Republic in Řež, dark fibre, GE transmission- Faculty of Nuclear and Physical Engineering of Czech Technical University, lambda on PASNET dark fibres by CWDM, GE transmission
Prague February 24th, 2005
CzechLight Testbed 8
Research Department APM Meeting www.ces.net
City dark fibre lines to the of CzechLight node in Prague
Point kmAttenuation 1550nm (dB)
max
Attenuation 1310nm (dB)
maxInstalling
Nuclear Physics Institute
25 5,9 9,64 1.9.2004Institute of
Physics Academy of
Sciences of CR 26 8,7 12,9 8.11.2004Faculty of
Mathematics and Physics 8,9 3,18 4,61 15.10.2004
Prague February 24th, 2005
CzechLight Testbed 9
Research Department APM Meeting www.ces.net
CzechLight configuration Core node in Prague
CISCO 15454 with 10 G DWDM SONET, 4xGECISCO C3550 – 12GCISCO C6503 with 10 GE and GE
Core node in BrnoCISCO 15454 with 10 G DWDM SONET, 4xGE
Prague February 24th, 2005
CzechLight Testbed 10
Research Department APM Meeting www.ces.net
PC Light Design Kit for wide area fibre networks, based on
racked PCs with build-in optical amplifier modules Multi-vendor (multi-source) building elements Preliminary comparison of OA (EDFA) costs:
– OA from „ISP vendor“: 40 000 USD– OA from „optical vendor“: 18 000 USD– OA from „module vendor“: 2 500 USD (two OA in module)– OA from Integrated Circuit vendor: 2000 USD/pc– OA + DCF costs are the biggest item in long distance
transmission systems costs (e.g. 60%)
=> PC Light helps to radically change WAN/MAN costs
Prague February 24th, 2005
CzechLight Testbed 11
Research Department APM Meeting www.ces.net
EDFA 2in1 v2.0: PC Light equipment example PC with build-in OA EDFA booster and preamp Successfully used for NIL GE connection from Plzen to
CzechLight in Prague by dark fibre pair (159.4 km, 36.7 dB) since May 2004
One Side Amplification (OSA NIL approach): this equipment is placed in Prague only. No OA equipment is placed in Plzen, so we expect lower service costs and higher availability (we have 24/7 staff in Prague only)
Advantages: low cost, small size (1U), redundant PSU, low power consumption, Linux, SNMP, reach up to 225 km, extensive management possibilities (Ethernet, GSM modem, BlueTooth, RS-232,…)
Prague February 24th, 2005
CzechLight Testbed 12
Research Department APM Meeting www.ces.net
EDFA 2in1: EDFA Module in Standard 1U PC with Linux
Alarm LEDs
BO IN
IDE +5V DCRS 232
PA OUT
BO OUT
FERS232C
USB * Network boot is also possible
PA IN
MicroATX MainBoard with
fanless CPU
Power Supply
Flash disc*
Low NF preamplifier
Booster
Prague February 24th, 2005
CzechLight Testbed 13
Research Department APM Meeting www.ces.net
PC Light forthcoming EDFA 2in1 tested in lab and production
environments PCLight Raman (fibre or diode) SOA amplifiers 1310 nm and 1550 nm Even true broadband (100 nm) amplifiers
for MAN
Prague February 24th, 2005
CzechLight Testbed 14
Research Department APM Meeting www.ces.net
Lighting of dark fibre: NIL update Production lines G.652, 1550 nm, EDFA
189 km Praha – Pardubice GE since May 2002
235 km Brno – Ostrava GE since June 2003 Experimental lines G.652, 1550 nm, EDFA
235 km Brno – Ostrava OC-48 June 2003
286 km Praha – Brno GE May 2004 (+Raman) More wavelengths possible
Prague February 24th, 2005
CzechLight Testbed 15
Research Department APM Meeting www.ces.net
NIL tests in laboratory G.652 fibre spools, EDFA + Raman:
325 km GE
250 km OC-48
252 km 2x 10 GE
302 km 10 G DWDM G.652 + G.655 fibre spools, EDFA + Raman
302 km 10 G DWDM
Prague February 24th, 2005
CzechLight Testbed 16
Research Department APM Meeting www.ces.net
Acknowledgement Jan Gruntorad for support and GLIF entry Miroslav Karasek for lighting of CESNET2
and CzechLight fibres
Comment: presented ideas and opinions are result of our ongoing R&D activities and are opened to improvement