Report from Module Bonding Working Group

27
CMS Tracker Week, CERN, 24-28 Oct 2005 26 Oct 2005 CMS Tracker Week - Module Product ion Salvatore Costa - Catania Report from Module Bonding Working Group Salvatore Costa Università di Catania and INFN – Sezione di Catania

description

Report from Module Bonding Working Group. Salvatore Costa Universit à di Catania and INFN – Sezione di Catania. Outline. Pull Test results Open issues Some peculiar failures. Global review of Module bonding quality that is, Module Pull Test results. # Modules Pull Tested. - PowerPoint PPT Presentation

Transcript of Report from Module Bonding Working Group

ModProd Mtg*
*
CMS Tracker Week - Module Production
*
*
*
CMS Tracker Week, CERN, 24-28 Oct 2005
*
*
that is,
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
CMS Tracker Week, CERN, 24-28 Oct 2005
*
*
CMS Tracker Week, CERN, 24-28 Oct 2005
*
*
Review of established practices in EU and US
Preparation for it in Italy
CMS Tracker Week - Module Production
*
*
*
v. 6.0
v. 6.0_US
*
*
*
Conductive Glue dots between gold pad and Sensor (at Gantry)
Conductive Glue reinforcement over gold pad and Sensor (normally at Gantry, occasionally at Bonding)
Bonds without encapsulation (at Bonding)
Bonds with encapsulation (at Bonding)
Current established practice:
US: 1 + 4 [existing TOB modules retrofitted]
Reason for reinforcement (EU) or encapsulation (US):
Bonds on back are considered at higher risk of being damaged when modules mounted on rods or petals because people’s attention is focused on front and the back may get neglected.
CMS Tracker Week - Module Production
Slide *
Material and Preparation
Sylgard 186 Silicone Elastomer, 2 part kit, 10:1 mixing ratio (manufacturer: Dow-Corning)
Mixing cups
Mixing sticks
CMS Tracker Week - Module Production
Slide *
Dispensing Equipment
Pneumatic glue dispenser with foot pedal and timed pulse option (manufacturer: EFD model: Ultra 1400) www.efd-inc.com
3ccm syringe barrel and piston (EFD)
Smooth-flow tapered tips, gage 20 (EFD)
CMS Tracker Week - Module Production
Slide *
Set up Equipment
Base plate (UCSB design), to hold the module on a module carrier upside down
Plastic trowel (UCSB design), to spread the encapsulant over the wirebonds and to keep the height of the encapsulant below the maximum height
Stereo microscope (optional)
Slide *
Mix encapsulant, degas the mixture and fill syringe
Set pneumatic dispenser to 15 psi and 1 second dispense time
Set module in carrier upside down onto base plate
Dispense a line of encapsulant across the width of the wirebonds
CMS Tracker Week - Module Production
Slide *
Procedure II
Position the trowel with one leg on the sensor, one leg on the kapton
Spread the encapsulant over all 15 wirebonds by sliding the trowel across the bonds
Once the trowel is past the wirebonds, lift it up and clean it off with a dry tissue paper
CMS Tracker Week - Module Production
Slide *
Procedure III
Check that all wirebonds are covered completely with the encapsulant (this can be done with or without a stereo microscope)
If necessary apply more silicone and repeat the troweling procedure
Cure for 24 hours with the backside of the module facing up to avoid beading up of the encapsulant
CMS Tracker Week - Module Production
9.unknown
M.Krammer:
no bond encapsulation experience in EU TEC community: use conductive glue reinforcement
All tests OK
This procedure is now officially requested by TEC to Italy
CMS Tracker Week - Module Production
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
How is Back bonding going?
Aachen: Vibration test of backplane HV bonds: with additional glue near bonds, but bonds bare, in one module some bonds broke, in another module no bonds broke. In modules with encapsulated bonds, none broke.
Strasbourg: Bonded (in hole) 16 modules electrically OK
Vienna: Bonded (in hole) 80 modules previously front-bonded, using special supports that hold module carrier all around: sensors not supportedNo problems.
Hamburg: Not started yet since the backplane jigs are not done before next week. For the last weeks have reinforced the glue connection on the backplane with conductive glue, for some modules where this had not been done before at the Gantries.
CMS Tracker Week - Module Production
*
*
*
Recipe for TEC Mod prod in Italy
At the end of the Bonding Meeting, I conveyed its outcome at the Gantry Meeting…
Bari has agreed to use conductive glue under HV pad when assembling modules
Bari has agreed to place conductive glue reinforcement over the “top” of the T-shaped pad
Bonding centers will bond “in the hole” without encapsulation
CMS Tracker Week - Module Production
CMS Tracker Week, CERN, 24-28 Oct 2005
*
*
*
*
*
IV failures:
Affect modules not randomly in time, but in concentrated clusters:
Recently: 5/53 in Aachen, 4/36 in Catania
Had also been seen at least in Catania and Padova in the past.
Seen (in Catania) first TIB module where gold layer on HV pad on back is peeling away.
May drag away the bonds with it
Module will be declared faulty Repair center
Since Sep we see many TIB PA’s where bonds would stick with unusually high parameters, or would not stick at all, in one or more of these locations:
Pads 1-2, 27-30, 738-741, 767-768
Seen in: Bari, Catania, Padova.
Suspect bad PA metallization in those (symmetric!) spots
CMS Tracker Week - Module Production