RENAL REPLACEMENT THERAPIES Presented by:

20
RENAL REPLACEMENT THERAPIES Presented by: Liz Ermitano Marlin Gomez Margarita Rodriquez Yumi Suzuki

description

 

Transcript of RENAL REPLACEMENT THERAPIES Presented by:

Page 1: RENAL REPLACEMENT THERAPIES Presented by:

RENAL REPLACEMENT THERAPIES

Presented by:Liz Ermitano

Marlin GomezMargarita Rodriquez

Yumi Suzuki

Page 2: RENAL REPLACEMENT THERAPIES Presented by:

RENAL REPLACEMENT THERAPIES

PURPOSES OF DIALYSIS1. Removes excess fluids and waste products.2. Restores chemical and electrolyte balance

HEMODIALYSIS‑ one of several renal replacement therapies used for the treatment of renal failure. HD involves the extracorporeal (outside of the body) passage of the client’s blood through a semi permeable membrane that serves as an artificial kidney.

Page 3: RENAL REPLACEMENT THERAPIES Presented by:

CLIENT SELECTIONGENERAL GUIDELINE REQUIREMENTS FOR APPROPRIATE CLIENT SELECTION

1. Presence of fatal, irreversible renal failure when other therapies are unacceptable or ineffective.

2. Absence of illnesses that would prevent or seriously complicate HD.

3. Expectation of rehabilitation.

4. The client’s acceptance of the regimen.

Page 4: RENAL REPLACEMENT THERAPIES Presented by:

Components of Hemodialysis

Dialyzer or artificial kidney

Dialyzer has 4 components: Blood compartment, Dialysate compartment, Semipermeable membrane, enclosed structure to support the membrane.

Dialysate – made up of clear H2O & chemicals. Compositions may be altered accdg to pt’s needs for treatment of electrolyte imbalance. Warmed to 37.8 C = to 100 F to increase efficiency of diffusion. Prevent decrease in pt’s blood temperature.

Vascular access routes – AV fistula, AV Graft, Dual Lumen Cathater, AV Shunt.

Hemodialysis machine -

Page 5: RENAL REPLACEMENT THERAPIES Presented by:
Page 6: RENAL REPLACEMENT THERAPIES Presented by:

PROCEDUREThe principles of HD are based on the passive transfer of toxins, which is accomplished by diffusion. When HD is initiated, blood and dialysate flow in opposite directions from their respective sides of an enclosed semi permeable membrane. The dialysate is a balanced mix of electrolytes and water that closely resembles human plasma. On the other side of the membrane is the client’s blood, which contains metabolic waste products, excess water, and excess electrolytes. During HD, the waste products move from the blood into the dialysate because of the difference in their concentrations (diffusion). Excess water is also removed from the blood into the dialysate (osmosis). Electrolytes can move in either direction, as needed, and take some fluid with them. Potassium and sodium typically move out of the plasma. This process continues as the blood and the dialysate are circulated past the membrane for a preset length of time.Duration and frequency of HD tx depend on the amt of

metabolic waste to be cleared, and the amt of fluid to be removed.

Page 7: RENAL REPLACEMENT THERAPIES Presented by:

COMPLICATIONS OF HEMODIALYSIS

Dialysis disequilibrium syndrome- the cause is

unknown but maybe due to rapid decrease in

blood urea nitrogen levels during HD. These change can cause cerebral edema- leads to increase intracranial pressure.

Infection- transmitted by blood transfusion are another serious complication associated with long term HD.

Hepatitis Infection- in clients with chronic renal failure.

Page 8: RENAL REPLACEMENT THERAPIES Presented by:

Best Practice for Caring for the client Undergoing Hemodialysis

Weigh the client before and after dialysis.Know the client’s dry weight.Discuss with physician whether any of the client’s medications should be withheld until after dialysis.Be aware of events that occurred during the dialysis treatment.Measure blood pressure, pulse rate, respirations, and temp.Assess for symptoms of orthostatic hypotension.Assess the vascular access site.Observe for bleedingAssess the client’s level of consciousness and assess for headache, nausea, and vomiting.

Page 9: RENAL REPLACEMENT THERAPIES Presented by:

COMPLICATIONS OF AV FISTULAE OR SYNTHETIC AV GRAFT

Stenosis‑the most frequent cause of permanent peripheral hemodialysis access failure is vascular stenosis.Thrombosis‑ this complication is more common in synthetic AV grafts than native AV fistulae.Failure of maturation‑ a native AV fistula requires 1 to 4 months to mature; if blood flow is diminished by stenosis or multiple outflow veins, maturation will be impaired.Infection‑ a leading cause of complications and death in dialysis patient. Typical S/S of an infected dialysis access include local erythema, induration, tenderness, and purulent drainage from incision sites.Ischemic steal syndrome‑ diverting blood flow from the distal extremity through the hemodialysis access may cause pain and ischemia in some patients, esp.diabetic and elderly patient.Pseudoaneurysm‑ also called false aneurysm or pulsating hematoma

Page 10: RENAL REPLACEMENT THERAPIES Presented by:

TYPES OF VASCULAR ACCESS FOR HEMODIALYSIS

Page 11: RENAL REPLACEMENT THERAPIES Presented by:

PERITONIAL DIALYSIS

Peritoneal dialysis (PD) takes place within the

peritoneal cavity. PD is slower than hemodialysis,

However , and more time is needed for the same

effect to be obtained.

Page 12: RENAL REPLACEMENT THERAPIES Presented by:
Page 13: RENAL REPLACEMENT THERAPIES Presented by:

TYPES OF PERITONEAL DIALYSIS CAPD

Continuous Ambulatory Peritoneal Dialysis

MBCAPD‑ Multiple‑Bag CAPD

APD‑ Automated Peritoneal Dialysis

IPD‑ Intermittent Peritoneal Dialysis

CCPD‑ Continuous Cycle peritoneal Dialysis

Page 14: RENAL REPLACEMENT THERAPIES Presented by:

PROCEDURE AND PROCESSThe surgical insertion of a siliconized rubber

(Sillastic) catheter into the abdominal cavity is

required to allow the infusion of dialyzing fluid

(dialysate) is infused according to the physician

order, 1 to 2L of dialysate is infused by gravity (fill)

into the peritoneal space over a 10 to 20 minutes

period, according to the client’s tolerance. The fluid

dwells in the cavity for a specified time ordered by the

physician. The fluid then flows out of the body (drain)

by gravity into a drainage bag.

Page 15: RENAL REPLACEMENT THERAPIES Presented by:

Con’t of process and procedure

the peritoneal outflow contains the dialysate in addition

to to the excess water, electrolytes, and nitrogenous

waste products that have accumulated in the body.

The Three Phases of the process:

1. Infusion or fill.

2. Dwell

3. Outflow or drain.

PD occurs through diffusion and osmosis across the

Semipermeable peritoneal membrane and adjacent

capillaries. The peritoneal membrane is large and porous.

it allows solutes, which carry fluid with them to move

by an osmotic gradient fr an area of higher concentra-

tion in the body (blood) to an area of lower concentration

in the dialyzing fluid.

Page 16: RENAL REPLACEMENT THERAPIES Presented by:

Complications of CAPD PERITONITIS‑the major complication of PD. The most

common cause of peritonitis is contamination of the connection site during an exchange. The infection of peritoneum is manifested by cloudy dialysate outflow (effluent), fever, rebound abdominal tenderness, abdominal pain, general malaise, nausea, and vomiting.

. Cloudy or opaque effluent is the earliest sign of peritonitis. The best treatment of peritonitis is prevention.

. The nurse must maintain meticulous sterile technique when caring for the PD catheter and when hooking up or clamping off dialysate bags.

Page 17: RENAL REPLACEMENT THERAPIES Presented by:

Con’t of Complication of CAPD

Pain- pain during inflow of dialysate is common during the first few exchanges because of peritoneal irritation; however, it disappear after a week or two. Cold dialysate aggravates discomfort. Thus the dialysate bags should be warmed before instillation by use of a heating pad to wrap the bag or use of warming chamber.

Microwave oven are not recommended for the warming of dialysate because of their unpredictable warming patterns and temperatures.

Exit Site and Tunnel infections- the normal exit site

from a PD catheter should be clean, dry, and with

out pain or evidence of inflammation.

Page 18: RENAL REPLACEMENT THERAPIES Presented by:

Con’t of Complication of CAPD

Insufficient flow of the Dialysate- Constipation is the primary

cause of inflow or outflow problems. To prevent constipation,

the physician orders a bowel preparation before placing the PD

catheter. The nurse ensures that the drainage bag is lower than

the client abdomen. The nurse inspects the connection tubing

and PD system for kinking or twisting and rechecks to make

sure that clamps are open.

Dialysate Leakage- when dialysis is initiated, small volumes of

dialysate are used. It may take clients 1 to 2 weeks to tolerate

a full 2-L exchange without leakage around the catheter site.

Other Complication- The nurse notes any change in the color of

the outflow.

Page 19: RENAL REPLACEMENT THERAPIES Presented by:

NURSING CARE DURING PERITONEAL DIALYSIS

Evaluate baseline vital signs

The client is weigh, always on the same scale, before the

beginning of the procedure or at least every 24 hours while

receiving the treatment.

Baseline laboratory value determination, such as electrolyte and

glucose levels,

During PD, the nurse continually monitors the client. For the first

exchanges, record the vs every 15 minutes. Ongoing assessment for respiratory distress, pain or discomfort. Abdominal dressing around the catheter exit site is checked frequently for wetness. Monitor for dwell time.

Page 20: RENAL REPLACEMENT THERAPIES Presented by:

NURSING CARE CON’T

For hourly exchanges, dwell time usually ranges from 20 to 40

Minutes. Blood glucose assessment is necessary, due to

Glucose absorption occur in some patient.

The outflow is recorded accurately after each exchange.

Visual inspection of the outflow bag and daily weights may be sufficient to note the adequacy of the return.

If drainage return is brown, a bowel perforation must be suspected.

If drainage return is the same color as urine and has the same glucose concentration, a possible bladder perforation should be investigated.

If drainage is cloudy or opaque, an infection is suspected.