TEST PIECE SERIAL NUMBERS
*refer to ATTACHMENT 6 for Test Piece Dimension and Coating Specification
TEST PARAMETER (AVERAGE)
HSF PARAMETER
Salinity, IN 5% Salinity, OUT 5%
pH Fog Collectors Data
pH in 7.2 Fog Collector 1 2.0 ml/hr/80cm2
pH out 6.5 Fog Collector 2 1.8 ml/hr/80cm2
Temperature Pressure
Saturated Air Temp 47OC Chamber Pressure 1 bar
Chamber Temp 35OC Air Intake Pressure 0.9 MPa
Hygrometer Downtime
Wet Bulb 35OC From -
Dry Bulb 35OC To -
UV PARAMETER
UV LAMP NO 4 PLACEMENT 360 DEGREE
WAVELENGTH 15W/ 450nm
HEATER NO 2 AVERAGE
TEMPERATURE 45 DEGREE C
ATTACHMENT
1. Salt Spray & UV Cabinet Specification
2. Salt Specification
3. Water Specification
4. pH meter specification
5. UV Lamp Specification
6. Samples Dimension and Coating Specification
7. Daily Progress Data Log
8. Photo Documentation
_______________________________________
This document may contain confidential information that is intended for the use of the parties to whom it is addressed. If you are not an intended recipient you are hereby
notified that any disclosure, copying, distribution or use of information in this document is strictly prohibited. If you receive this document in error please notify us at the
telephone number indicated below. All information and attachments remain the property of Enviropeel Holdings LLC and should be held as confidential.
ENVIROPEEL HOLDINGS LLC
1128 South West Street, Indianapolis, Indiana 46225 Tel: +1 317 631-9100 Email: [email protected]
PRODUCT
DATE 01.04.2014
HOUR
COUNTER 9000
TIME TO
10000 1000hr / May 14
NO SERIAL ORIENTATION NO SERIAL ORIENTATION
1 EMY-008 HORIZONTAL 2 EMY-009 VERTICAL
UV CYCLIC PROGRESS REPORT
9000 HOURS
Copyright © Enviropeel Holdings 2018
Attachment 1
Salt spray and UV cabinet specification
*Note – An identical Salt Cabinet was modified to accommodate the UV lamps and test samples. Heaters were included to maintain temperature in the cabinet.
Copyright © Enviropeel Holdings 2018
Attachment 2
Salt specification
Copyright © Enviropeel Holdings 2018
Attachment 3
Water specification
Ordering information
®
Easy maintenance
®
Simple installation
Installing your Milli-DI® system will only take you a few minutes:
Tubing, fitting, 9 volt battery and tape are accessories provided with your Milli-DI® system.
Specifications
Resistivity: > 1 MΩ.cm at 25 °CFlow rate: 0.5 L/min to 0.7 L/min
14 psi < Feedwater pressure < 70 psiPotable tap water
For bacteria free water
Accurate control of water quality
Dimensions
Copyright © Enviropeel Holdings 2018
Attachment 4
Ph meter specification
Copyright © Enviropeel Holdings 2018
Attachment 5
UV LAMP DATASHEET & specification
Copyright © Enviropeel Holdings 2018
Copyright © Enviropeel Holdings 2018
Attachment 6
Sample dimension and coating specification
HOUR COUNTER
MONTH WEEK 1 WEEK 2 WEEK 3 WEEK 4
672 1 UV UV HSF UV
1344 2 UV HSF UV UV
2016 3 HSF UV UV HSF
2688 4 UV UV HSF UV
3360 5 UV HSF UV UV
4032 6 HSF UV UV HSF
4704 7 UV UV HSF UV
Indicates the samples in UV Cabinet
Indicates the samples in HSF Cabinet
Material :MildSteelSize :6"/4"ClosedEnd,DependingonavailablespaceCoatingSpec :Minimumcoatedsinglelayer.ExposedBoltsandNutswillbeleftuncoated
Enviropeel :2LayersofE170TestDuration :6identicaltestpieces.2foreachtestdurationwithdifferentorientation.(Pleaserefertodiagrambelow)
Copyright © Enviropeel Holdings 2018
Attachment 7
Daily progress data log
MA
Y 2
01
3
JUN
E 2
01
3
Copyright © Enviropeel Holdings 2018
JUL
Y 2
01
3
AU
GU
ST 2
01
3
Copyright © Enviropeel Holdings 2018
SEP
TE
MB
ER
20
13
O
CT
OB
ER
20
13
Copyright © Enviropeel Holdings 2018
NO
VE
MB
ER
20
13
D
EC
EM
BE
R 2
01
3
Copyright © Enviropeel Holdings 2018
JAN
UA
RY
20
14
F
EB
RU
AR
Y 2
01
4
Copyright © Enviropeel Holdings 2018
MA
RC
H 2
01
4
AP
RIL
20
14
Copyright © Enviropeel Holdings 2018
Attachment 8
Photo documentation
UV Cabinet showing sample arrangement
Sample welded to the neck with closed ends
Blasted sample Minimum coated single layer and prepared for Enviropeel application
Copyright © Enviropeel Holdings 2018
0 HOUR
336 HOURS
1848 HOURS
Copyright © Enviropeel Holdings 2018
2016 HOURS
2352 HOURS
2520 HOURS
Copyright © Enviropeel Holdings 2018
2688 HOURS
2856 HOURS
3096 HOURS
Copyright © Enviropeel Holdings 2018
3768 HOURS
4032 HOURS
4200 HOURS
Copyright © Enviropeel Holdings 2018
4368 HOURS
4536 HOURS
4872 HOURS
Copyright © Enviropeel Holdings 2018
5040 HOURS
5376 HOURS
5880 HOURS
Copyright © Enviropeel Holdings 2018
NOTES & OBSERVATION
• Sample EMY-008 & EMY-009 spend two (2) weeks in UV Cabinet at average temperature of 40 Degree C and one (1) week in Hot Salt Fog Cabinet and was repeated in this order and cycle.
• The UV Lamps were arranged to maximize exposure from every angle. • No significant effects were observed and Enviropeel external coating was intact and unaffected. • Conclusion: Despite the intensity and duration of this test, it was not possible to detect any
detrimental effects to the integrity of the protection provided by Enviropeel. No cracking, discoloration or reduction in oil content of the coating material was found.
• Follow up note (2014): The test was continued successfully until 9000 hrs was reached. A follow-up report is being prepared.