Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

9
Ref: P .ppt (31/08/22) 1 EUROTHERM CONTROLS 2704 2704 Vacuum Block Vacuum Block

description

Ref: P.ppt (06/03/2016) 3 EUROTHERM CONTROLS Typical Application Hi Vac Gauge Temperature Control Loop Heating Cooling Setpoint Programmer mB Vacuum Function Block Temp SP Program Events Run Hold Reset Thermocouple C Lo Vac Gauge mB Backing Gauge mB Program Wait Signal SP1 SP2 SP6 Vacuum Valves PLC Interlocks

Transcript of Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Page 1: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 1EUROTHERM CONTROLS

2704 2704 Vacuum BlockVacuum Block

Page 2: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 2EUROTHERM CONTROLS

Vacuum FeatureVacuum Feature

1 or 3 input gauges Polyfit linearisation Scientific display in mB,Torr,

Pascal Bumpless auto gauge switchover 6 On/Off setpoint outputs High vacuum gauge enable

signal Roughing pump timer Leak detection routine Displays Chamber Vacuum + 2nd

value with user text

Page 3: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 3EUROTHERM CONTROLS

Typical ApplicationTypical Application

Hi Vac Gauge

TemperatureControl Loop

HeatingCooling

Setpoint Programmer

mB

VacuumFunction

Block

Temp SP

ProgramEvents

RunHoldReset

Thermocouple C

Lo Vac Gauge mB

Backing Gauge mB

Program Wait Signal

SP1

SP2

SP6

Vacuum Valves PLC Interlocks

Page 4: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 4EUROTHERM CONTROLS

Gauge switch-overGauge switch-over

Switch-over block

Hi Vac Gauge mB

Lo Vac Gauge mB

Chamber Vacuum

Page 5: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 5EUROTHERM CONTROLS

Gauge Switch-over Gauge Switch-over

1.0-E08 Increasing

vacuum(mB)

1.0+E03

1.0-E06

1.0-E04

1.0-E02

1.0+E00

Pirani measurement range

10vdc2vdcAIM or Penning measurement range

10vdc

Switch-over region Chamber Vacuum =

50:50

Page 6: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 6EUROTHERM CONTROLS

CommunicationsCommunicationsLeak detectLeak detect

Leak detect

Chamber Vacuum

Leak detected

•Leak Detect Time•Target leak Rate Pump off

Start Leak Detect

LEAK DET

Page 7: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 7EUROTHERM CONTROLS

Profibus-DPProfibus-DPCommunicationsCommunicationsRoughing Pump Time-outRoughing Pump Time-out

Roughing Pump Time-

out

Chamber Vacuum

Time-out

•Time•Target Vacuum

Pump off

Start

PUMP TOUT

Page 8: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 8EUROTHERM CONTROLS

Profibus-DPProfibus-DPCommunicationsCommunicationsHi Vac. Gauge EnableHi Vac. Gauge Enable

Gauge Enable

Backing Vacuum

Gauge On

•Setpoint

Low Vacuum GON

Page 9: Ref: P.ppt (06/03/2016) 1 EUROTHERM CONTROLS 2704 Vacuum Block.

Ref: P .ppt (08/05/23) 9EUROTHERM CONTROLS

Profibus-DPProfibus-DPCommunicationsCommunicationsError IndicationError Indication

Gauge 1 Status

ERROR

Gauge 3 Status

Gauge 2 Status