Ref: P .ppt (04/19/23) 1EUROTHERM CONTROLS
2604–2704 Multi-loop Controllers
• Overview of Main Features• Input/output Hardware• Control features• Setpoint programmer• Special application blocks• Toolkit Blocks• Digital communications• User Interface customisation• Software Tools• Selling Messages
2704 Version 6 Release
Ref: P .ppt (04/19/23) 4EUROTHERM CONTROLS
3 Control Loops3 Control Loops• PID, VP and On/Off• 6 PID sets per loop• Cascade & Override• Ratio
Advanced ControlAdvanced Control• Zirconia probe input• Wet & Dry Humidity• Direct vacuum inputs• Boiler TDS
ProgrammerProgrammer• 60 programs• 600 Segments• 3 profiles/program•16 event outputs
Expansion IOExpansion IO• Din rail unit• 20 Digital inputs• 20 Digital outputs• 24V Supply
Custom DisplaysCustom Displays• Loop overviews• Operators lists • Alarm messages• User messages• User Screens (2704)
HardwareHardware• Standard IO• 2 Analog IP, 10 dig IO• 5 IO Module slots• Max 5 TC/RTD inputs
Digital CommsDigital Comms• Modbus slave• Modbus master• Profibus DP slave• DeviceNet slave• EI Bisync
ToolKit BlocksToolKit Blocks• Analogue operations• Digital operations• Timers & totalisers• Real time clock
26/2704 Product Overview26/2704 Product Overview
Ref: P .ppt (04/19/23) 5EUROTHERM CONTROLS
Input/Output HardwareInput/Output HardwareStandard I/OStandard I/O
• Universal PV input• -10 to +10vdc input• 1(2) Digital input• 7 Bi-directional digital I/O• 1 Changeover relay • I/O Expansion comms
Modular I/O Modular I/O • 5 I/O Slots• Most isolated 2400 modules
-Additional 26/27 modules-240Vac Isolation
• 2 Comms Slots-2400 modules
Expansion I/O Expansion I/O • 20 Digital inputs• 20 Digital outputs
Ref: P .ppt (04/19/23) 6EUROTHERM CONTROLS
Module AvailabilityModule Availability
OUTPUT BOARDSOUTPUT BOARDS• Change over relay• 2 pin relay• Dual relay• Single Triac• Dual Triac• Analog DC control• Analog Dual DC(26/2704)• Analog DC retransmission• Hi-Res DC retrans(26/2704)• Isolated single logic• Triple logic output
INPUT BOARDSINPUT BOARDS• Precision PV input (26/2704)• Analog input (26/2704)• Dual PV input (26/2704)• TDS input(2704)• Triple logic input• Triple contact input• Potentiometer input
POWER SUPPLY BOARDSPOWER SUPPLY BOARDS• 24 volt transmitter supply• 5 & 10 volt transducer supply• Dual 24Vdc supply(26/2704)
COMUNICATION BOARDSCOMUNICATION BOARDS• 232 Modbus or EI-BISYNC• 422 Modbus or EI-BISYNC• 485 Modbus or EI-BISYNC• Profibus• DeviceNet
Note: 232, 422, 485 boards can be used as modbus master or slave
Ref: P .ppt (04/19/23) 7EUROTHERM CONTROLS
Additional 26/2704 ModulesAdditional 26/2704 Modules
Analogue Input (AM)Analogue Input (AM)• Slots 1,3,4 or 6• Same Spec as 2400 DC input module• 3uV resolution• TC, RTD, mV, mA, Volts, High Z volts
PV Input (PV)PV Input (PV)• Slots 3 & 6• 0.25uV Resolution• TC/RTD/mV/mA,Volts input, High Z volts
Dual Analogue Input (DP)Dual Analogue Input (DP)• Slots 3 & 6• Inputs not isolated from each other• 1 TC/RTD/mV/mA & 1 Volts input• Ideal for carbon probe input
Ref: P .ppt (04/19/23) 8EUROTHERM CONTROLS
Additional 26/2704 ModulesAdditional 26/2704 Modules
Dual DC Output (DO)Dual DC Output (DO)• Slots 1,4 or 5• Each channel 4-20mA or 24Vdc PSU• 12bit resolution• Channel isolation
HiRes DC Retransmission (HR)HiRes DC Retransmission (HR)• Slots 1,4 or 5• Chan1=4-20mA, Chan2=24Vdc PSU• 16Bit resolution(very low noise)• Channel Isolation• Should be used in “feedback” mode(ref TIBC167)
TDS(Total dissolved solids) Input (TD)TDS(Total dissolved solids) Input (TD)• Slots• Conductivity measurement• 0.4Vpp probe excitation• 0-500mS range
Ref: P .ppt (04/19/23) 10EUROTHERM CONTROLS
2000 IO Expander2000 IO Expander
• Din-Rail mountingDin-Rail mounting
• Proprietary communicationsProprietary communications
• 24Vac/dc powered24Vac/dc powered24Vdc output
• Max 20 InputsMax 20 Inputs24Vdc isolated
• Max 20 OutputsMax 20 OutputsVolt free relay
• Two versions availableTwo versions available10in/10out20in/20out
Ref: P .ppt (04/19/23) 11EUROTHERM CONTROLS
Control FunctionsControl Functions
Up to 3 independent control loopsUp to 3 independent control loops• Autotune & gain scheduling• Cascade, ratio or override• Feedforward functions• Remote setpoint input• Remote power limits• Input track • Transducer scaling• Output characterisation• PV/SP Trending per loop (2704)
Ref: P .ppt (04/19/23) 12EUROTHERM CONTROLS
Setpoint ProgrammerSetpoint Programmer
• 60 Programs• 3 SP profiles/Program• 600 segments• Ramp Rate or Time to Target• Program & segment names• 16 Digital event outputs• Programmer mimic (2704)
Ideal for Ideal for • Multi-variable applications
Carburising Furnaces Test Chambers Autoclaves
• Multi-zone applications Creep & tensile testing 3 Zone furnaces Semiconductor Diffusion
Ref: P .ppt (04/19/23) 13EUROTHERM CONTROLS
2704 Vacuum Block2704 Vacuum Block
Application Software OptionApplication Software Option• V1 = 1 gauge input• V3 = 3 gauge input
Application Specific VersionApplication Specific Version• 2704VC
Function Block FeaturesFunction Block Features• 1 or 3 gauge input• PV in scientific format• Hi-Vac enable output• Auto Hi-Lo transfer• 6 switched outputs• Roughing pump timer• Leak detection
Ref: P .ppt (04/19/23) 14EUROTHERM CONTROLS
26/2704 Zirconia Probe Input26/2704 Zirconia Probe Input
Application Software OptionApplication Software Option• ZC = Zirconia controller
Application Specific VersionApplication Specific Version• 26/2704CP
Function Block FeaturesFunction Block Features• Most probes supported• PV in carbon potential, dewpoint or oxygen• Sooting alarm• Automatic probe clean• Clean recovery alarm• Probe impedance monitor
Ref: P .ppt (04/19/23) 15EUROTHERM CONTROLS
26/2704 Humidity Block26/2704 Humidity Block
Standard FeatureStandard Feature• Included in all controllers
Application Specific versionApplication Specific version• Model X26, OEM product
Function Block FeaturesFunction Block Features• Wet & dry technique• PV in %RH and Dewpoint• Altitude compensation• Solid State sensors use standard 4-20mA input
Ref: P .ppt (04/19/23) 16EUROTHERM CONTROLS
Toolkit BlocksToolkit Blocks
DetailsDetails• 32 Digital operators• 32 Analogue calculations• 50 User values• 4 User Switches• Timers & totalisers• Pattern generator• Digital programmer• Wiring block• Multiple input block
Toolkit BlocksToolkit Blocks• Used to create custom configurations• Equivalent to 900EPC user wiring• Provides maths & PLC functions
Ref: P .ppt (04/19/23) 17EUROTHERM CONTROLS
Standard(XX) unit includesStandard(XX) unit includes• 8 digital operations• Timers, totalisers and input operators• 4 user values
Toolkit 1 (U1) includes Standard plusToolkit 1 (U1) includes Standard plus• 16 analog operations• 8 digital operations(16 total)• Pattern generator• Digital programmer• Analogue Switch• 4 User values
Toolkit 2 (U2) includes Toolkit 1 plusToolkit 2 (U2) includes Toolkit 1 plus• 8 Analog operations (24 total)• 16 Digital operations (32 total)• 8 User values (12 total)
Toolkit Blocks – What you get
Ref: P .ppt (04/19/23) 18EUROTHERM CONTROLS
Standard Function Blocks
Timer BlocksTimer Blocks• 4 Available• On Pulse, Off Delay, One Shot, Min-On timer
TotalisersTotalisers• 4 Available• Provides a running total of a parameter and gives an output when a preset total is reached
Real Time ClockReal Time Clock• Day of week and time of day• Can be used to start other functions
Monitor blockMonitor block• Logs min and max values• Counts time above a threshold and provides alarm
Ref: P .ppt (04/19/23) 19EUROTHERM CONTROLS
Standard Function Blocks
Custom Linearisation Custom Linearisation • 3 Available, 16 point custom fit• Can be applied to any parameter
Switchover Switchover • Provides a smooth transition between 2 sensors
BCD Input BCD Input • Calculation of decimal value from BCD input• Used mainly for program number selection
Transducer Scaling Transducer Scaling • 3 Available• Shunt(melt pressure), load Cell or comparison Cal• Auto tare function
Ref: P .ppt (04/19/23) 20EUROTHERM CONTROLS
Digital ProgrammerDigital Programmer
Interfaces to Setpoint Programmer Interfaces to Setpoint Programmer • Timed control of a single output • Provides timed program event outputs • 4 separate outputs• 8 On/Off times• Run, Hold and Reset inputs
Ref: P .ppt (04/19/23) 21EUROTHERM CONTROLS
DigitalPattern No1
D OP 1
D OP 2
D OP 8
D OP 3
D OP 4
D OP 5
D OP 6
D OP 7
ON
ON
OFF
ON
ON
ON
ON
OFF
D OP 16 ON
Pattern GeneratorPattern Generator
Interfaces to Setpoint ProgrammerInterfaces to Setpoint Programmer• Provides advanced digital functions • 16 patterns can be stored• Patterns can be given meaningful names• Each pattern can have 16 outputs• 2 patterns can be active at any one time
Ref: P .ppt (04/19/23) 22EUROTHERM CONTROLS
Analogue Switch Analogue Switch Provides the user with the facility to select an analogue value based on an input index
• 8 Switches available• 8 Values per switch• Range limits & resolution• Values and Selection can be given meaningful names
Analogue SwitchAnalogue Switch
Ref: P .ppt (04/19/23) 23EUROTHERM CONTROLS
Analogue Switch Analogue Switch Provides the user with the facility to select an analogue value based on an input index
• 8 Switches available• 8 Values per switch• Range limits & resolution• Values and Selection can be given meaningful names
Multiple Input BlockMultiple Input Block
Ref: P .ppt (04/19/23) 24EUROTHERM CONTROLS
Analogue Switch Analogue Switch Provides the user with the facility to select an analogue value based on an input index
• 8 Switches available• 8 Values per switch• Range limits & resolution• Values and Selection can be given meaningful names
Wiring BlockWiring Block
Ref: P .ppt (04/19/23) 25EUROTHERM CONTROLS
Digital CommunicationsDigital Communications
Support for EI-Bisync Support for EI-Bisync • Parameter subset only
Slave Communications Slave Communications • 2 Communication slots• EIA232, EIA485 2 or 4 wire• Profibus DP• DeviceNet• Profibus DP/ Devicenet in slot H and itools in slot J is possible
Ref: P .ppt (04/19/23) 26EUROTHERM CONTROLS
Modbus Master CommunicationsModbus Master Communications
Uses Standard Modbus ModulesUses Standard Modbus Modules• EIA 232 or 485• Slot J only, 9600 baud• Standard in all units
8 Individually Addressed Slaves8 Individually Addressed Slaves• Broadcast mode = address 0
Possible SlavesPossible Slaves• S2000, 900EPC, 2500, 5100v plus more!• Third party devices
25 Parameters in 260425 Parameters in 2604
100 Parameters in 2704100 Parameters in 2704
Ref: P .ppt (04/19/23) 27EUROTHERM CONTROLS
User Interface CustomisationUser Interface CustomisationSummary views Summary views
• Loop summaries• Instrument summary view• Naming of loops• 10 Promoted parameters• Parameter renaming• Setting of access levels
Others UI features Others UI features • Programmer names• Segment names(2704)• Setpoint profile names• Alarm messages• 8 User messages• User screens(2704)• Custom enumerations
Ref: P .ppt (04/19/23) 28EUROTHERM CONTROLS
2704 User Pages2704 User Pages Max 8 customisable pages Max 8 customisable pages
• 7 Formats available• User selectable parameters & text• 10 parameter scroll list
Ref: P .ppt (04/19/23) 29EUROTHERM CONTROLS
Enumerations can be applied toEnumerations can be applied to• User values• Program user values• Pattern generator• Analog switch values• Digital programmer• Digital IO status parameters• Logic operator output status
Custom EnumerationsCustom EnumerationsCustom Enumeration Custom Enumeration Provides the user with the facility to enumerate
parameters with their own text
For example when a digital input =1 the user interface shows “Door Open” and when =0 itshows “Door closed”
Ref: P .ppt (04/19/23) 30EUROTHERM CONTROLS
Software Tools
ITools ITools • Configuration• Archiving of clone files• Setpoint program editing• Process trending• Data-logging• OPC connectivity
Profibus GSD Editor Profibus GSD Editor • Generates GSD file required by master
Ref: P .ppt (04/19/23) 31EUROTHERM CONTROLS
Process InputsProcess Inputs
• Reinforced(240Vac) isolation
• Excellent accuracy and stability
• 5 digit display with 0.25uV resolution
• RTD resolution better than 0.01ºC
• Controls to better than 0.1ºC @ 1500 ºC
• Max 8 analogue inputs
Ref: P .ppt (04/19/23) 32EUROTHERM CONTROLS
Excellent ControlExcellent Control
• Eurotherm PID and VP control algorithms
• Standard Cascade, Override and Ratio options
• Simultaneous view of all control loops
• Trending of setpoint and process variable
• Vacuum function block
• Zirconia function block
• Flexible control strategies
Ref: P .ppt (04/19/23) 33EUROTHERM CONTROLS
Setpoint ProgrammingSetpoint Programming
• Synchronised programming of three variables
• Easy editing and selection of programs
• Ramp Rate or Time to Target
• Customer defined program & segment names
• Graphical view of program status
• Flexible use of setpoint profiles
• Itools Setpoint Program Editor
Ref: P .ppt (04/19/23) 34EUROTHERM CONTROLS
User InterfaceUser Interface
• 2704 User Screens
• Provides operators easy access to parameters via loop summary lists
• Improve operator views by custom enumerating parameters with meaningful text
• Customised alarm messages
• Provide operator with prompts to perform an operation
Ref: P .ppt (04/19/23) 35EUROTHERM CONTROLS
Cost Competitive integrated solutionCost Competitive integrated solution
Combined in a single packageCombined in a single package• 3 Control Loops• Advanced setpoint programmer• Application function blocks• Analogue calculations• PLC logical operations• Excellent operator interface• Open communications
Ref: P .ppt (04/19/23) 36EUROTHERM CONTROLS
•Analogue inputs•High accuracy & stability•Full isolation - 240Vac
•Eurotherm PID control•Guaranteed performance•Easy set-up
•Setpoint Programmer•Fully featured•Easy to use
•Dedicated application blocks•Zirconia input•Direct vacuum measurement
•Toolkit blocks•Flexible control options
•Open Communications•Simple connection to master PLCs
26/2704 - Heat Treatment26/2704 - Heat Treatment
Applications•Atmosphere heat treatment•Vacuum heat treatment•Composite curing autoclaves•Materials testing & research•Ceramic/Brick kilns•Semiconductor crystal growing
Ref: P .ppt (04/19/23) 37EUROTHERM CONTROLS
•Analogue inputs•Extremely accurate RTD measurement
•Eurotherm PID control•Reliable performance•Multiple PID sets
•Setpoint Programmer•3 Synchronised profiles•Flexible, yet easy to use
•Dedicated Humidity application block•Wet & dry measurement•%RH or dewpoint control
•Toolkit blocks•Flexible control options•Compressor timing etc
•Open Communications•Simple connection to master PLCs
26/2704 - Environmental Control26/2704 - Environmental Control
Applications•Environmental testing•Semiconductor burn-in•Culture & plant growth•Incubators•Brick drying ovens•Paint drying ovens
Ref: P .ppt (04/19/23) 38EUROTHERM CONTROLS
•Analogue inputs•Direct input of variety of sensors
•Eurotherm PID control•Reliable & Guaranteed performance
•Setpoint Programmer•Standard feature, no need for expert programming
•Dedicated application blocks•Humidity, zirconia, vacuum & boiler
•Toolkit blocks•Creates custom solutions•Small machine control•Eliminates need for PLC
•Open Communications•Simple connection to master PLCs•Master Modbus to slave controllers
26/2704 - Solution Provider26/2704 - Solution Provider
Applications•Extrusion melt pressure•pH Controller•Mini fermenters•Carbon probe monitor•Rubber test machines•Wellhead pressure testing•Fuel/Air combustion control