Radiation damage of 1600Pixel MPPC by neutrons

9
Radiation damage of 1600Pixel MPPC by neutrons ILC-CAL meeting University of tsukuba H.Yamazaki

description

Radiation damage of 1600Pixel MPPC by neutrons. ILC-CAL meeting University of tsukuba H.Yamazaki. Dose rate. Flux = 1.5×10 9 neutron/cm 2 /Wh (W = watt, h = hour) …… calculated MCNP ( Monte Carlo Neutron and Photon Transport Code System ) Code. 4 dose rate patterns - PowerPoint PPT Presentation

Transcript of Radiation damage of 1600Pixel MPPC by neutrons

Page 1: Radiation damage of  1600Pixel MPPC by neutrons

Radiation damage of 1600Pixel MPPC by neutrons

ILC-CAL meeting

University of tsukuba

H.Yamazaki

Page 2: Radiation damage of  1600Pixel MPPC by neutrons

Dose rate

Flux = 1.5×109 neutron/cm2/Wh (W = watt, h = hour)

…… calculated MCNP ( Monte Carlo Neutron

  and Photon Transport Code System ) Code  

                    4 dose rate patterns                     ↓1.5×109 neutron/cm2 /Wh×12.5/60 h×1W =3.125×108 neutron/cm2

1.5×109 neutron/cm2 /Wh×12.5/60 h×10W =3.125×109 neutron/cm2

1.5×109 neutron/cm2 /Wh×12.5/60 h×100W =3.125×1010 neutron/cm2

1.5×109 neutron/cm2 /Wh×12.5/60 h×1kW   =3.125×1011 neutron/cm2

Page 3: Radiation damage of  1600Pixel MPPC by neutrons

Uniformity of Sample (Noise Rate,Cross-talk Probability )

The individual difference of several percent was confirmed to four samples.

Sample irradiated with 3.125×108  n/cm2

Sample irradiated with 3.125×109  n/cm2

Sample irradiated with 3.125×1010 n/cm2

Sample irradiated with 3.125×1011 n/cm2

Cross-talk Probability Noise Rate (Vbias)

Noise Rate (Vover )

Page 4: Radiation damage of  1600Pixel MPPC by neutrons

Measurement after the irradiation

Noise Rate Cross-talk Probability

(at Vbias = -77.5V) before 108 n/cm2 109 n/cm2

NoiseRate(Hz) 346,236 569,263 3,157,690 Increased of Noise Rate 160% 910%Crosstalk probability 0.158 0.144 0.171

Noise Rate rises as dose rate goes up,Cross-talk dose not change so much by irradiation

Before the irradiation3.125×108 n/cm2

3.125×109 n/cm2

Before the irradiation3.125×109 n/cm2

3.125×109 n/cm2

Page 5: Radiation damage of  1600Pixel MPPC by neutrons

Measurement after the irradiation ( 3.125×108 n/cm2)

Noise Rate Cross-talk Probability

several times measurement after irradiation

2007 11/14 Before irradiation 11/16 Just after irradiation 12/05 Before annealing at 60 ゜ C 12/06 After annealing at 60 ゜ C 12/15 The additional measurement 1 12/15 The additional measurement 2

Page 6: Radiation damage of  1600Pixel MPPC by neutrons

Measurement after the irradiation ( 3.125×109 n/cm2)

Cross-talk Probabirity Noise Rate

several times measurement after irradiation

2007 11/14 Before irradiation 11/16 Just after irradiation 12/05 Before annealing at 60 ゜ C 12/06 After annealing at 60 ゜ C 12/15 The additional measurement 1 12/15 The additional measurement 2

Page 7: Radiation damage of  1600Pixel MPPC by neutrons

Summary• Noise Rate rises as dose rate gose up• Cross-talk dose not change so much by irr

adiation• There are some problems for the noise rate

measurement

Plan Another analysis

…….Gain,NoiseRate(Vbias correction),After Pulse

Page 8: Radiation damage of  1600Pixel MPPC by neutrons

Back Up

Page 9: Radiation damage of  1600Pixel MPPC by neutrons

Noise Rate (Reference)