R ANGE OF L OW VOL T A GE C ABLES...R ANGE OF L OW VOL T A GE C ABLES Kelani Cables PLC Overhead...
Transcript of R ANGE OF L OW VOL T A GE C ABLES...R ANGE OF L OW VOL T A GE C ABLES Kelani Cables PLC Overhead...
RA
NG
E
OF
L
OW
V
OL
TA
GE
C
AB
LE
S
Kelani Cables PLC
Overhead Lines
Aerial Bundled Cables (ABC) with messenger neutral core
Application: Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises
Engineering Speci�cations
Type : Al/XLPEStandard : NF C 33-209Nominal Voltage : 600/1000V Insulating Sheath : XLPE compoundPacking : The ABC are delivered on non-returnable wooden drums
ABC – 3xA mm² Al/XLPE + NxAmm² Al alloy/XLPE + KxAmm² Cu/XLPE (A-Cross sectional area of conductor, N-Neutral (Al alloy), K-no of cores for public lighting)
Technical Information
No / Stranding wire diameter Insulation Thickness Conductor DC Resistance Max. Breaking Strength Nominal Area of Conductor
Phase Street
lighting Phase Neutral
Street lighting
Nominal Drum
Length
Drum size
mm 2 Ω /km Ω /km daN daN daN m
3x25 + N 54.6 + 1x16
3x35 + N 54.6 + 1x16
3x50 + N 54.6 + 1x16
3x70 + N 54.6 + 1x16
3x70 + N 54.6 + 1x25
3x70 + N 70 + 1x16
3x95 + N 70 + 1x16
3x120 + N 70 + 1x16
3x120 + N 95 + 1x16
3x150 + N 70 + 1x16
3x150 + N 95 + 1x16
Phase
x/mm
7/2.0
7/2.33
7/2.70
7/3.3
7/3.3
7/3.3
7/3.73
7/4.06
7/4.06
7/4.7
7/4.7
Neutral
x/mm
7/3.17
7/3.16
7/3.16
7/3.16
7/3.16
7/3.5
7/3.5
7/3.5
7/4.16
7/3.5
7/4.16
Street lighting
x/mm
7/1.6
7/1.6
7/1.6
7/1.6
7/2.0
7/1.6
7/1.6
7/1.6
7/1.6
7/1.6
7/1.6
Phase
mm
1.4
1.6
1.6
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
Neutral
mm
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.6
1.5
1.6
Street lighting
mm
1.2
1.2
1.2
1.2
1.4
1.2
1.2
1.2
1.2
1.2
1.2
0.253
1.2
0.868
0.641
0.443
0.443
0.443
0.320
0.253
0.206
0.206
Neutral
Ω /km
0.63
0.63
0.63
0.63
0.63
0.50
0.50
0.50
0.343
0.50
0.343
1.91
1.91
1.91
1.91
1.20
1.91
1.91
1.91
1.91
1.91
1.91
300
420
600
840
840
840
1140
1440
1440
1800
1800
1660
1660
1660
1660
1660
2050
2050
2050
2750
2050
2750
190
190
190
190
300
190
190
190
190
190
190
1000
1000
700
650
600
600
500
450
425
400
400
Kel 28
Kel 30
Kel 29
Kel 29
Kel 29
Kel 29
Kel 28
Kel 28
Kel 28
Kel 28
Kel 28
Current carrying capacity
Nominal Area of Conductor
Phase conductor Street lighting conductor
Voltage Drop Inductance Impedance Min Bending
Radius (Bundle)
Approximate overall diameter
Approximate Weight
A A mV/A/m mH/km Ω/km mm mm kg/km
112 229
138 229
168 229
3x70 + N 54.6 + 1x16 213 243
213 243
213 243
258 266
6 300 284
300 284
3x150 + N 70 + 1x16 344 315
3x150 + N 95 + 1x16
3x25 + N 54.6 + 1x16
3x35 + N 54.6 + 1x16
3x50 + N 54.6 + 1x16
3x70 + N 54.6 + 1x25
3x70 + N 70 + 1x16
3x95 + N 70 + 1x16
3x120 + N 70 + 1x
3x120 + N 95 + 1x16
344
111
83
83
83
83
83
83
83
83
83
83
2.2
1.65
1.27
0.87
0.87
0.87
0.67
0.55
0.55
0.46
0.46
0.28
0.28
0.27
0.26
0.26
0.26
0.25
0.25
0.25
0.24
0.24
0.501
0.501
0.50
0.35
0.35
0.35
0.258
0.258
0.258
0.257
0.257 315
30
33
36
37.5
40
41
44
46
47
48
49
580.7
687.8
801.6
1042.3
1077.3
1079.9
1262.8
1417.1
1480.3
1727.5
1790.7