Page 2: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Roof drainage systems

conventional ( or gravity*) roof drainage systems (air + water)

siphonic roof drainage systems (water only OR full bore flow)

Siphonic systems are based on gravity effect too but this designation is used for an easy distinction.

2VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 3: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Roof drainage systems

All roof drainage systems are made of:

roof outlets,

pipes and fittings,

clamps and accessories.

3VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 4: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Conventional roof drainage systems

Conventional roof drainage systems are made of:

standard outlets,

one stack for each outlet,

stacks’ height equal to the building height.

4VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 5: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Conventional drainage systems

Conventional roof drainage systems are made of :

Collectors buried in the ground (even inside the building),

sloped collectors,

Max stack water filling ratio 33% Max collectors water filling ratio 70%

5VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 6: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic roof drainage systems

Siphonic roof drainage systems are made of :

roof outlets with anti-vortex plate,

horizontal collectors installed under the soffit

One single downpipe for each circuit

6VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 7: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic roof drainage systems

Siphonic roof drainage systems are made of :

Downpipes position freely definable (generally on the perimeter of the building,

Horizontal collectors (no slope required)

7VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 8: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Conventional roof drainage systems

The outlets of traditional roof drainage systems have no particular insert.

The water flows inside the pipes with a vortex and carrying air.

Pipelines work if appropriate volumes of air are allowed into the pipes.

8VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 9: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic roof drainage systems

In the syphonic systems the outlet is equipped with an anti-vortex plate preventing any air to go inside the pipes.

Pipelines work in a full bore scenario.

9VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 10: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic roof drainage systems

The full bore flow systems is based on the application of the Bernoulli principle.

This principle fixes a relationship between the velocity and the pressure of the water.

10VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Page 11: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic roof drainage systems

11VALSIR S.p.A. – Ufficio Progettazione Impianti

The engine of siphonic systems is the height of the circuit that generates negative pressure inside the pipes (vacuum).

Negative pressure siphons the water from the roof outlets.

Negative pressure

Neg

ative pressu

re

RainplusThe siphonic drainage

Page 12: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic systems advantages

12VALSIR S.p.A. – Ufficio Progettazione Impianti

Economical Minimization of the number of roof outlets, Minimization of the pipes size, Minimization of the number of downpipes. Drastic reduction of materials quantities

Space saving Horizontal pipes without any slope, The downpipes can be installed anywhere

RainplusThe siphonic drainage

Page 13: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic systems advantages

13VALSIR S.p.A. – Ufficio Progettazione Impianti

High performance Pipes are sized to work completely

full of water, high velocity of the water (up to

9m/sec) the system is self cleaning.

Eco-sustainable This system makes the collection

of rain water easy and economical (down pipes positioned in correspondence of water harvesting tanks)

RainplusThe siphonic drainage

Page 14: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Siphonic system advantages

14VALSIR S.p.A. – Ufficio Progettazione Impianti

Time and labour saving Excavation works are minimized thus making

the installations quicker. Smaller pipes = quicker installations Less material = quicker installations

Great design flexibility Down pipes can be installed anywhere in the

building, The drainage lines are not buried in the

ground.

RainplusThe siphonic drainage

Page 15: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Technical comparison

15VALSIR S.p.A. – Ufficio Progettazione Impianti

Example Roof area of 2500 m2. Rainfall intensity 108 mm/h.

RainplusThe siphonic drainage

Page 16: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

16VALSIR S.p.A. – Ufficio Progettazione Impianti

Flow rate of 18.75 l/s

Flow rate of 18.75 l/s

RainplusThe siphonic drainage

Technical comparison Example Roof area of 2500 m2. Rainfall intensity 108 mm/h.

Page 17: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

17VALSIR S.p.A. – Ufficio Progettazione Impianti

Flow rate of 37.5 l/s

RainplusThe siphonic drainage

Technical comparison Example Roof area of 2500 m2. Rainfall intensity 108 mm/h.

Page 18: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

18VALSIR S.p.A. – Ufficio Progettazione Impianti

De 90

De 200

De 200

De 110

De 125

De 110

De 250

Conventional system Roof outlets: 14 x OD 90mm Downpipes: 14 x OD 90mm Side collectors: OD 110 – 200mm Central collector: OD 125 – 250mm

RainplusThe siphonic drainage

Technical comparison

Page 19: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Technical comparison

19VALSIR S.p.A. – Ufficio Progettazione Impianti

De 200

De 200

De 110

De 125

De 110

De 250

Conventional system Pipe: 270 m Fittings: 75 pcs Cost: 8.500 EUR

De 90

RainplusThe siphonic drainage

Page 20: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Technical comparison

20VALSIR S.p.A. – Ufficio Progettazione Impianti

De 160

De 110

Siphonic system Outlets: 9 (Rainplus 50-110) Downpipes: 1 x OD 160 Side collectors: OD 90 – 110mm Central collector: OD 110 – 125mmDe 90

De 110

De 90De 125

De 110

RainplusThe siphonic drainage

Page 21: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Technical comparison

21VALSIR S.p.A. – Ufficio Progettazione Impianti

De 160

De 110

Siphonic system Pipes: 190 m -30% Fittings: 67 pcs -11% Cost: 6.000 Euro -29%

De 90

De 110

De 90De 125

De 110

RainplusThe siphonic drainage

Page 22: R AINPLUS AND CONVENTIONAL SYSTEMS : A COMPARISON 1VALSIR S.p.A. – Ufficio Progettazione Impianti.

Technical comparison – figures

Conventional Siphonic

Roof outlets 14 9

Downpipes 14 1

Side collectors size 110-200 90-110

Central collector size 125-250 110-125

Pipe quantity 270m 190m

Fittings quantity 75 pcs 67

Cost € 8.500 € 6.000

22VALSIR S.p.A. – Ufficio Progettazione Impianti

RainplusThe siphonic drainage

Less labour + Less materials = less costsFor a more efficient installation