Industrial Wall-mount Managed Gigabit Ethernet Switch WGS-804HPT WGS-4215-8T/WGS-4215-8T2S/WGS-4215-8P2S WGS-4215-16P2S Quick Installation Guide

Transcript of Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge...

Page 1: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

Industrial Wall-mount Managed Gigabit Ethernet Switch

WGS-804HPT

WGS-4215-8T/WGS-4215-8T2S/WGS-4215-8P2S

WGS-4215-16P2S

Quick Installation Guide

Page 2: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

Table of Contents

1. Package Contents ....................................................................................... 3

2. Requirements ............................................................................................. 4

3. Wiring the Power Inputs .............................................................................. 5

3.1 Terminal Block Connector Pinout ........................................................... 6

3.2 DC Power Jack .................................................................................... 6

4. Hardware Installation .................................................................................. 7

4.1 Wall Mount Installation ......................................................................... 7

4.2 Magnet Installation .............................................................................. 8

4.2.1 Magnet Installation of WGS-4215-16P2S ...................................... 8

4.3 DIN-rail Mount Installation ................................................................... 9

5. Web Login .................................................................................................11

5.1 Starting Web Management ..................................................................11

5.2 SavingConfigurationviatheWeb ........................................................14

6. Telnet Login ..............................................................................................15

6.1 ConfiguringIPAddress ........................................................................16

6.2 StoringtheCurrentSwitchConfiguration ..............................................17

7. RecoveringBacktoDefaultConfiguration .....................................................18

8. Customer Support .....................................................................................19

Page 3: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

3

1. Package ContentsThank you for purchasing PLANET Industrial Wall-mount Managed Gigabit Switch,WGS-804HPT and WGS-4215 series. The table below shows the models with the number of ports:

Model Name10/100/1000T Copper Ports

802.3atPoEPorts

100/1000 SFP Fiber Optical Interface

WGS-4215-8T 8 – –

WGS-4215-8T2S 8 – 2

WGS-804HPT 8 4 –

WGS-4215-8P2S 8 8 2

WGS-4215-16P2S 16 16 2

In the following section, unless specified, the term “Wall-mount Managed Switch” mentioned in this quick installation guide refers to the above models.

Open the box of the Wall-mount Managed Switch and carefully unpack it. The box should contain the following items:

The Wall-mount Managed Switch x 1

Quick Installation Guide x 1 pc

3-pin Terminal Block Connector x 1 pc

(Vary on the model)

DIN-rail Kit x 1 set Magnet Kit x 1 set Wall-mounted Kit x 1 set

RJ45 Dust Cap x 8 pcs SFP Dust Cap x 2 pcs

(x16 for WGS-4215-16P2S only) (WGS-4215-8T2S/WGS-4215-8P2S/WGS-4215-16P2S only)

If any item is found missing or damaged, please contact your local reseller forreplacement.

Page 4: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

4

2. Requirements z Workstations runningWindows XP/2003/Vista/7/8/2008/10, MAC OS X or later,Linux,UNIX,orotherplatformsarecompatiblewithTCP/IPprotocols.

z Workstations are installed with Ethernet NIC (Network Interface Card)

z EthernetPortConnection

Networkcables--Usestandardnetwork(UTP)cableswithRJ45connectors.

The above PC is installed with Web browser and JAVA runtimeenvironmentplug-in.

Note

ItisrecommendedtouseInternetExplorer8.0orabovetoaccessthe Wall-mount Managed Switch. If the Web interface of the Wall-mountManagedSwitch is not accessible, please turn off the anti-virus software or firewall and then try it again.

Page 5: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

5

3. Wiring the Power InputsThe Wall-mount Managed Switch features a strong dual power input system (terminal block and DC jack) incorporated into customer’s automation network to enhance system reliability and uptime.

Power Input Range

Model3-pin Terminal Block DC Jack

WGS-4215-8T 12~48VDC,24VAC 12~48VDC,24VAC

WGS-4215-8T2S 12~48VDC,24VAC 12~48V DC

WGS-804HPT 48~56V DC 48~56V DC

WGS-4215-8P2S 48~56V DC 48~56V DC

WGS-4215-16P2S 48~56V DC 48~56V DC

NoteMax power requirement also rely on the real site application.

10/100/1000BASE-T RJ45 Port

10/100/1000BASE-T RJ45 Port

3-pin Terminal Block

DC Plug-in

Page 6: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

6

3.1 Terminal Block Connector PinoutTo install the 3-pin Terminal BlockConnector on theWall-mountManagedSwitch,simply follow the following steps:

Step 1: Insert positive DC power wire into V+, negativeDC powerwire intoV-,and grounding wire into Ground.

V+

V -

Ground

Step 2: Tighten the wire-clamp screws for preventing the wires from loosening and plug into the Wall-mount Managed switch.

Note

1.Thewiregaugeshouldbeintherangefrom12to24AWG.2. The device must be grounded.

3.2 DC Power JackThe WGS-804HPT/WGS-4215-8P2S/WGS-4215-16P2S requires DC 48V~56V power input and WGS-4215-8T/WGS-4215-8T2S requires DC 12~48V power input. Should you have the issue of power connection, please contact your local salesrepresentative.

2.1mm

DC Receptacle 2.1mm

DC receptacle is 2.1mm wide that conforms to the WGS-4215 series 2.1mm DC jack's central post. Do not install any improper power adaptor

Page 7: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

7

4. Hardware Installation4.1 Wall Mount InstallationTo install theWall-mountManagedSwitch on thewall, simply follow the followingsteps:

Step 1: It is required 4 holes with 8mm diameter on the wall; the distance between the 2 holes is 133mm (WGS-804HPT/WGS-4215-8T), 163mm(WGS-4215-8T2S/WGS-4215-8P2S),230mm(WGS-4215-16P2S)andtheline through them must be horizontal.

Step 2: Install a conductor pipe inside the board hole and flush the edge of theconductor pipe with the wall surface.

Step 3: Screw the bolts into the conductor pipe. The Wall-mount Managed Switch isbetweenboltsandconductorpipe,asshownbelow.

W

D

Vary on model

Distance (mm) 8-port 8+2S 16+2S

W 133 163 230

D 118 118 124

Page 8: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

8

4.2 Magnet InstallationToinstalltheWall-mountManagedSwitchonamagneticsurface,simplyfollowthefollowing diagram:

4.2.1 Magnet Installation of WGS-4215-16P2SStep 1: There are six holes in front, using six sets ofmagnets to install. Please

refer to the following.

Step 2: Turntheswitchtotheback,thenscrewthemagnettothemiddlehole.

SYS

PWR180W

240W

SFP

17

18

120W

60W

57

31

68

42

1315

119

1416

1210

PoE

DC Input Range48-56V

V+

Ground

SFP17

18

WGS-4215-16P2S

ManagedFiber

PoE+Magnet Mounting

PoE-in-Use

LNK/ACT

PoE Usage

ACTLNK

ACTLNK

1000100

Page 9: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

9

Warning

Asthemagneticmountingdoesnotfixcompletely,whendeployingthe switch please be aware that the equipment will not fall or break due to vibration or dragging.

Note

Please use the screw from the Magnet kit to avoid breaking the device.

4.3 DIN-rail Mount InstallationThe DIN-rail kit is included in the package. When the wall-mount application for the Wall-mountManagedSwitchneeds tobe replacedwithDIN-rail application,pleaserefer to the following figures to screw the DIN-rail on the Wall-mount ManagedSwitch.TohanguptheWall-mountManagedSwitch,followthestepsbelow:

Step 1: Screw the DIN-rail on the Wall-mount Managed Switch.

Page 10: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

10

Step 2: Lightly insert the DIN-rail into the track.

1 Push

2 Click

Step 3: Check whether the DIN-rail is tightly on the track.

Page 11: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

11

5. Web Login5.1 Starting Web ManagementThe following shows how to start up the Web Management of the Wall-mount Managed Switch. Note the Wall-mount Managed Switch is configured through anEthernet connection. Pleasemake sure themanager PCmust be set to the sameIP subnet address.

For example, the default IP address of the Wall-mount Managed Switch is192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100) and the default subnet mask is255.255.255.0.

PC / Workstationwith Web Browser

192.168.0.x

Managed Switch

RJ45/UTP Cable

IP Address:192.168.0.100

Figure 5-1: IP Management Diagram

Page 12: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

12

Logging in to the Wall-mount Managed Switch1.Use Internet Explorer 8.0 or above Web browser and enter IP address

http://192.168.0.100 to access the Web interface.

2.When the following dialog box appears, please enter “admin” in both the defaultusernameandpasswordfields.TheloginscreeninFigure5-2appears.

DefaultIPAddress:192.168.0.100DefaultUsername:adminDefault Password: admin

Figure 5-2: Web Login Screen

3.Afterenteringthepassword,themainscreenappearsasFigure5-3shows.

Note

The following web screen is based on the WGS-4215-8T2S. The display of the WGS-4215-8T2S is the same as those of the WGS-804HPT and WGS-4215-8T/WGS-4215-8P2S/WGS-4215-16P2S.

Page 13: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

13

Figure 5-3: Web Main Screen of Wall-mount Managed Switch

The Switch Menu on the left of the Web page lets you access all the commands and statistics the Wall-mount Managed Switch provides.

Figure 5-4: Switch Menu

Now, you can use the Web management interface to continue the Switchmanagement. Please refer to the user’s manual for more.

Page 14: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

14

5.2 SavingConfigurationviatheWebIn the Wall-mount Managed Switch, the running configuration file stores in theRAM. In the current version, the running configuration sequence of running-config can be saved from the RAM to FLASH by “Save Configurations to FLASH” function,so that therunningconfigurationsequencebecomes thestartupconfigurationfile,whichiscalledconfigurationsave.

To save all applied changes and set the current configuration as a startupconfiguration, the startup-configuration file will be loaded automatically across asystem reboot.

1. Click “Save > Save Configurations to FLASH” to login “ConfigurationManager” Page.

2. Press the “Apply” button to save running configuration to start up configura-tion.

Page 15: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

15

6. Telnet LoginThe Wall-mount Managed Switch also supports Telnet for remote management. The switch asks for user name and password for remote login when using Telnet; please use “admin” for both username and password.

Default IP address: 192.168.0.100Username:adminPassword: admin

Figure 6-1: Wall-mount Managed Switch Telnet Login Screen

The user can now enter commands to manage the Wall-mount Managed Switch. Foradetaileddescriptionofthecommands,pleaserefertothefollowingchapters.

Note

1. For security reason, please change and memorize the new passwordafterthisfirstsetup.

2. Only accept command in lowercase letter under console inter-face.

Page 16: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

16

6.1 ConfiguringIPAddressThe Wall-mount Managed Switch is shipped with default IP address shown below:

IPAddress:192.168.0.100Subnet Mask: 255.255.255.0

TocheckthecurrentIPaddressormodifyanewIPaddressfortheSwitch,pleaseuse the procedure as follows:

DisplayoftheCurrentIPAddress1.Atthe “#”prompt,enter“show ip”.

2. The screen displays the current IP address shown in Figure 6-2.

Figure 6-2: IP Information Screen

ConfigurationoftheIPAddress3.At the “#”prompt,enter the followingcommandandpress<Enter> as shown

in Figure 6-3.

WGS-4215-8P2S#configure terminalWGS-4215-8P2S(config)#ip address 192.168.1.100 mask 255.255.255.0WGS-4215-8P2S(config)#ip default gateway 192.168.1.254

Page 17: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

17

The previous command would apply the following settings for the Wall-mount Managed Switch.

IPAddress:192.168.1.100Subnet Mask: 255.255.255.0Gateway: 192.168.1.254

Figure 6-3: Configuring IP Address Screen

4. Repeat step 1 to check if the IP address has changed.

6.2 StoringtheCurrentSwitchConfigurationAtthe“#”prompt,enterthefollowingcommandandpress<Enter>.

# copy running-config startup-config

Figure 6-4: Saving Current Configuration Command Screen

If the IP is successfully configured, theWall-mountManagedSwitchwill apply thenew IP address setting immediately. You can access the Web interface of the Wall-mount Managed Switch through the new IP address.

Note

If you are not familiar with the Telnet command or the related parameter, enter “help” anytime in console to get the help description.

Page 18: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

18

7.RecoveringBacktoDefaultConfigurationIPAddresshasbeenchangedoradminpasswordhasbeenforgotten–To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the reset button on the front panel for about 5 seconds. After the device is rebooted, you can log in theWeb interfacemanagement within the same subnet of 192.168.0.xx.

Figure 7-1: WGS-804HPT/WGS-4215-8T Reset Button

Figure 7-2: WGS-4215-8T2S/WGS-4215-8P2S Reset Button

17Reset

100/1000X

18

Figure 7-3: WGS-4215-16P2S Reset Button

Page 19: Quick Installation Guide...Step 2: Install a conductor pipe inside the board hole and flushthe edge of the conductor pipe with the wall surface. Step 3: Screw the bolts into the conductor

19

8. Customer SupportThank you for purchasing PLANET products. You can browse our online FAQresourceandUser’sManualonPLANETWebsitefirsttocheckifitcouldsolveyourissue.Ifyouneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.

PLANETonlineFAQs:https://www.planet.com.tw/en/support/faq

Switch support team email address:[email protected]

WGS-804HPT/WGS-4215-8T/WGS-4215-8T2S/WGS-4215-8P2S/WGS-4215-16P2S User’sManual:https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=WGS&view=3#list

Copyright © PLANET Technology Corp. 2018.Contents are subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.