Quick Guide NewClassic Balances MS-S / MS-L Models · UNIT 2 >> 8. g ¦ mg. NO KEY BEEP >> 8 ......

2
C 1 2 3 4 7 5 6 9 8 10 • Cancel running application NET WEIGHING 0.00 g 0.00 g 121.01 g 0.00 g Net 22.00 g Unit 1 , * 22.00 g M Recall , 0. 78 oz Unit 2 Execute the assigned F1 application. Factory setting: "Piece Counting" Execute the assigned F2 application. Factory setting: "Percent Weighing" Execute the assigned F3 application. Factory setting: "Checkweighing" F1 F2 F3 Activate weighing application • if activated • if different from Unit 1 • if activated # , M NewClassic Balances MS-S / MS-L Models Quick Guide Easy Weighing Access Quick Application Access Direct Adjustment Access External Adjustment Procedure Switching Units Application Settings Operation Keys Display Panel Tare Press and hold Press briefly Press briefly Press and hold Press and hold Press and hold Note: There is a timeout during the setup. The balance switches back to the last active application. Press briefly Press briefly Execute predefined adjusting (calibration) procedure Factory Setting: Internal adjustment (MSxxxE models: external adjustment) COUNTING FIX 10 PCS PERCENT SET 100 % CHECK SET NOM. Weight Value Field Application Icons Status Icons Unit Field Status Icons Weighing-in aid Application Icons Menu locked Menu settings activated Application “Weighing” Application “Piece counting” Application “Percent weighing” Application “Check weighing” Application “Statistics” Application “Formulation / Net-Total” Application “Totaling” Application “Dynamic weighing” Application “Multiplication factor” Application “Division factor” Application “Density” Status Icons Indicates stored values (memory) Indicates Net weight values Adjustments (calibration) started FACT activated Diagnostic mode & Application “Routine test” activated Service reminder Acoustic feedback for pressed keys activated Weighing range 1 (Dual Range models only) Weighing range 2 (Dual Range models only) Charge of battery; full, 2/3, 1/3, discharged (Battery operated models only) Unit Field Marking of weighing units: g gram kg kilogram mg milligram ct carat lb pound oz ounce ozt troy ounce GN grain dwt pennyweight mom momme msg mesghal tlh Hong Kong taels tls Singapore taels tlt Taiwan taels tola tola baht baht >> Selection available Weighing-in aid Marking of nominal or target weight Marking of tolerance limit T+ Marking of tolerance limit T- Weight Value Field Indicates negative values Indicates unstable values Indicates calculated values Indicates uncertified digits (approved models only) Key Functions No. Key Press briefly (less than 1.5 s) Press and hold (longer than 1.5 s) 1 • To change display resolution (1/10d function) while application is running Note: not available with approved models in selected countries no function 2 • Enter or leave menu (Parameter settings) no function 3 • Execute predefined adjusting (calibration) procedure no function 4 • Printout display value • Printout menu settings • Transmit data no function 5 • To navigate back (scroll up) within menu topics or menu selections • Decrease (numerical) parameters within menu and in applications • To select the weighing application • Decrease (numerical) parameters quickly within menu and in applications 6 • To navigate forward (scroll down) within menu topics or menu selections • Increase (numerical) parameters within menu and in applications • To select assigned F1 application and enter- ing the parameter settings of application. • Default F1 application assignment: Piece counting • Increase (numerical) parameters quickly within menu and in applications 7 • With entries: scroll down • To navigate through menu topics or menu selections • To toggle between unit 1, recall value (if selected), unit 2 (if different from unit 1) and the application unit (if any) • To select assigned F2 application and enter- ing the parameter settings of application. • Default F2 application assignment: Percent weighing 8 • To enter or leave menu selection (from / to menu topic) • To enter application parameter or switch to next parameter • To store parameter • To select assigned F3 application and enter- ing the parameter settings of application. • Default F3 application assignment: Check- weighing 9 ON/OFF # • Switch on • Zero/Tare • Switch off 10 C • Cancel and to leave menu without saving (one step back in the menu). • no function Net ADJ.EXT 1000.00 g ------ 0.00 g ------ ADJ DONE 0.00 g

Transcript of Quick Guide NewClassic Balances MS-S / MS-L Models · UNIT 2 >> 8. g ¦ mg. NO KEY BEEP >> 8 ......

Page 1: Quick Guide NewClassic Balances MS-S / MS-L Models · UNIT 2 >> 8. g ¦ mg. NO KEY BEEP >> 8 ... Quick Guide NewClassic Balances MS-S / MS-L Models Subject: Quick Guide NewClassic

C

1

2

3

4

75 6 9 810

• Cancel running application

NET

WEIGHING

0.00 g

0.00 g

121.01 g

0.00 g Net

22.00 g Unit 1,

* 22.00 g M Recall,

0.78 oz Unit 2

Execute the assigned F1 application. Factory setting: "Piece Counting"

Execute the assigned F2 application. Factory setting: "Percent Weighing"

Execute the assigned F3 application. Factory setting: "Checkweighing"

F1

F2

F3

Activate weighing application

• if activated• if different

from Unit 1

• if activated

#

,

C

C

M

NewClassic BalancesMS-S / MS-L Models

Qui

ck G

uide

Easy Weighing Access Quick Application Access Direct Adjustment Access

External Adjustment Procedure

Switching Units

Application Settings

Operation Keys Display Panel

Tare

Press and hold

Press briefly

Press briefly

Press and hold

Press and hold

Press and hold

Note:There is a timeout during the setup. The balance switches back to the last active application.

Press briefly

Press briefly

Execute predefined adjusting (calibration) procedureFactory Setting: Internal adjustment(MSxxxE models: external adjustment)

COUNTING

FIX 10 PCS

PERCENT

SET 100 %

CHECK

SET NOM.

Wei

ght V

alue

Fie

ld

Application Icons Status Icons

Unit

Fiel

d

Status IconsWeighing-in aid

Application Icons

Menu locked

Menu settings activated

Application “Weighing”

Application “Piece counting”

Application “Percent weighing”

Application “Check weighing”

Application “Statistics”

Application “Formulation / Net-Total”

Application “Totaling”

Application “Dynamic weighing”

Application “Multiplication factor”

Application “Division factor”

Application “Density”

Status Icons

Indicates stored values (memory)

Indicates Net weight values

Adjustments (calibration) started

FACT activated

Diagnostic mode & Application “Routine test” activated

Service reminder

Acoustic feedback for pressed keys activated

Weighing range 1 (Dual Range models only)

Weighing range 2 (Dual Range models only)

Charge of battery; full, 2/3, 1/3, discharged (Battery operated models only)

Unit Field

Marking of weighing units:g gramkg kilogrammg milligramct caratlb poundoz ounceozt troy ounceGN graindwt pennyweightmom mommemsg mesghaltlh Hong Kong taelstls Singapore taelstlt Taiwan taelstola tolabaht baht

>> Selection available

Weighing-in aid

Marking of nominal or target weight

Marking of tolerance limit T+

Marking of tolerance limit T-

Weight Value Field

Indicates negative values

Indicates unstable values

Indicates calculated values

Indicates uncertified digits (approved models only)

Key Functions

No. Key Press briefly (less than 1.5 s) Press and hold (longer than 1.5 s)

1

• To change display resolution (1/10d function) while application is running Note: not available with approved models in selected countries

no function

2

• Enter or leave menu (Parameter settings) no function

3

• Execute predefined adjusting (calibration) procedure

no function

4

• Printout display value• Printout menu settings• Transmit data

no function

5

• To navigate back (scroll up) within menu topics or menu selections

• Decrease (numerical) parameters within menu and in applications

• To select the weighing application• Decrease (numerical) parameters quickly

within menu and in applications

6

• To navigate forward (scroll down) within menu topics or menu selections

• Increase (numerical) parameters within menu and in applications

• To select assigned F1 application and enter-ing the parameter settings of application.

• Default F1 application assignment: Piece counting

• Increase (numerical) parameters quickly within menu and in applications

7

• With entries: scroll down• To navigate through menu topics or menu

selections• To toggle between unit 1, recall value (if

selected), unit 2 (if different from unit 1) and the application unit (if any)

• To select assigned F2 application and enter-ing the parameter settings of application.

• Default F2 application assignment: Percent weighing

8

• To enter or leave menu selection (from / to menu topic)

• To enter application parameter or switch to next parameter

• To store parameter

• To select assigned F3 application and enter-ing the parameter settings of application.

• Default F3 application assignment: Check-weighing

9 ON/OFF#

• Switch on• Zero/Tare

• Switch off

10 C • Cancel and to leave menu without saving (one step back in the menu). • no function

Net

ADJ.EXT

1000.00 g

------

0.00 g

------

ADJ DONE

0.00 g

Page 2: Quick Guide NewClassic Balances MS-S / MS-L Models · UNIT 2 >> 8. g ¦ mg. NO KEY BEEP >> 8 ... Quick Guide NewClassic Balances MS-S / MS-L Models Subject: Quick Guide NewClassic

Mettler-Toledo AGLaboratory WeighingCH-8606 Greifensee, Switzerland

Subject to technical changes© Mettler-Toledo AG 01/2014 11781215F en

www.mt.com/newclassic

*11781215*

Topic SelectionDATE.FORM>> 8 DD.MM.Y

MM/DD/Y

Y-MM-DD

D.MMM Y

MMM D Y

TIME.FORM>> 8 24:MM

12:MM

24.MM

12.MM

RECALL >> 8 OFF

ON

SHUTOFF >> 8 A.OFF10 min

A.OFF -

A.OFF 2 min

A.OFF 5 min

BCKLIGHT >> 8 B.L. ON

B.L. 30 s

B.L. 1 min

B.L. 2 min

B.L. 5 min

DISPLAY >> 8 BRIGHTN. >> 8 50 %

CONTRAST>> 8 75 %

AUTOZERO>> 8 ON

OFF

ZERO RNG>> 8 21.00 g

LANGUAGE>> 8 ENGLISH

DEUTSCH

FRANCAIS

ESPANOL

ITALIANO

RUSSIAN

POLSKI

CESKY

MAGYAR

NEDERL.

BR.PORTUG.

ASSIGN:F1>> 8 COUNTING

PERCENT

CHECK

STAT

FORMULA

TOTALING

DYNAMIC

FACTOR M

FACTOR D

DENSITY

ASSIGN:F2>> 8 PERCENT

CHECK

¦ ¦COUNTING

ASSIGN:F3>> 8 CHECK

¦ ¦R.TEST

COUNTING

PERCENT

DIAGNOSE>> 8 REPEAT.T

DISPLAY

KEYPAD T

CAL.MOT. T

BAL.HIST

CAL.HIST

BAL.INFO

PROVIDER

SERV.ICON>> 8 ON

OFF

SRV.D.RST>> 8 NO?

YES?

BASIC >> 8  

ADVANCED>>  8

INT.FACE >> 8

PROTECT >> 8

,

+8

C

Basic Menu

Advanced Menu

Interface Menu

Protection

• Enter menu• Leave menu

with saving

Scroll down

Menu Map

Scroll up

• Enter selection or menu

• Execute setting

• One step back• Leave menu

without saving

Menu Operation

Main Menu

Basic Menu

Advanced Menu

Topic Selection

DATE >> 8 01.01.2008

TIME >> 8 +1H

-1H

SET TIME>> 8 12:00

UNIT 1 >> 8 g

¦kg

UNIT 2 >> 8 g ¦

mg

NO

KEY BEEP >> 8 MED

HIGH

OFF

LOW

STAB.BEEP>> 8 LOW

MED

HIGH

OFF

RESET >> 8 NO?

YES?

Topic Selection

WEIG.MODE>> 8 UNIVERS.

DOSING

ENVIRON.>> 8 STANDARD

UNSTABLE

STABLE

CAL >> 8 ADJ.INT

ADJ.EXT >> 8 200.00 g

ADJ.OFF

ADJ.CUST.F>> 8 EXECUTE

RESET >> 8 NO?

YES?

FACT >> 8 TIME >> 8 12:00

OFF

FACT PRT>> 8 ON

OFF

Interface MenuTopic Selection

RS232 >> 8 PRINTER >> 8  PRT.STAB

PRT.AUTO

PRT.ALL

PC-DIR. >>. 8 PRT.STAB

PRT.AUTO

PRT.ALL

HOST >> 8 SEND.OFF

SEND.STB

SEND.CONT

SEND.AUTO

SEND.ALL

2.DISPLAY ¥

HEADER >> 8 NO

DAT/TIM

D/T/BAL

SINGLE >> 8 NET

G/T/N

SIGN.L >> 8 OFF

ON

LINE.FEED >> 8 0

ZERO PRT.>> 8 OFF

ON

COM.SET >> 8 MT-SICS

MT-PM

SART

BAUDRATE >> 8 9600

¦4800

BIT/PAR. >> 8 8/NO

7/NO

7/MARK

7/SPACE

7/EVEN

7/ODD

STOPBIT >> 8 1 BIT

2 BITS

HD.SHAKE >> 8 XON/XOFF

RTS/CTS

OFF

RS.TX.E.O.L.>> 8 <CR><LF>

<CR>

<LF>

<TAB>

RS CHAR >> 8 IBM/DOS

ANSI/WIN

USB >> 8 PC-DIR. >>. 8  PRT.STAB

PRT.AUTO

PRT.ALL

HOST >> 8 SEND.OFF

SEND.STB

SEND.CONT

SEND.AUTO

SEND.ALL

USB COMS.>> MT-SICS

MT-PM

SART

USB E.O.L.>> 8 <CR><LF>

<CR>

<LF>

<TAB>

USB CHAR>> 8 ANSI/WIN

IBM/DOS

INTERVAL>> 8 0 s

Topic SelectionPROTECT>> 8 OFF

ON

Protection

Legend Factory setting Only those weight units allowed by the appropriate

national legislation are selectable. Not available with MSxxxE models. Not available with MSxxxKLIPE models. Not available with approved models. Not available with approved models

(except OIML accuracy class I approved models)¥ Settings are automatically set for the 2nd display.

Software version V2.20

For more information

600…38400