ProTech903™ D1 / CE · ProTech903™ D1 / CE Tape Analyzer for Phosgene [email protected] | +1...
Transcript of ProTech903™ D1 / CE · ProTech903™ D1 / CE Tape Analyzer for Phosgene [email protected] | +1...
-
ProTech Introduction• Tape Technology for Gas-Phase Samples• Manufactured In & Supported From Calgary, AB• Backed by 40 Years of Experience in Natural Gas
Rapid Return-On-Investment• Never Miss Unexpected Upset• Guaranteed Contractual Compliance• Ensure Product Quality Specifications
Measurement Certainty• 0.005 ppm LDL Every 3 Minutes• Predictive Alarm in ≤ 20 Seconds• 10 Months Data Logging Storage• Multi-Stream Up to 4 Channels• CSA Div. 1; ATEX / IECEx Zone 1
Key Applications• Polymer Production• Pesticides Manufacturing• Polyurethane Toluene Diisocyanate Synthesis
On-Board Calibration• Phosgene Bottled Cal Gas Not Easily Available• Permeation Tube Device Eliminates Gas Cylinders• Mounted Near Analyzer in Climate-Controlled Box
ProTech903™ D1 / CETape Analyzer for Phosgene
[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. August 2019 | Specifications Subject to Change Without Notice
ProTech903™ D1 / CE
-
ProTech903™ D1 / CETape Analyzer for Phosgene
[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. August 2019 | Specifications Subject to Change Without Notice
Extended-Life Tape With No Interferences Convenient Permeation Tube Calibration
Secure Remote Access With Advanced DiagnosticsLarge Local Display With LED Indicators
-
ProTech Introduction• Tape Technology for Gas-Phase Samples• Manufactured In & Supported From Calgary, AB• Backed by 40 Years of Experience in Natural Gas
Rapid Return-On-Investment• Never Miss Unexpected Upset• Guaranteed Contractual Compliance• Ensure Product Quality Specifications
Measurement Certainty• 0.005 ppm LDL Every 3 Minutes• Predictive Alarm in ≤ 20 Seconds• 10 Months Data Logging Storage• Multi-Stream Up to 4 Channels• CSA Class 1 Div. 2 Certified
Key Applications• Polymer Production• Pesticides Manufacturing• Polyurethane Toluene Diisocyanate Synthesis
On-Board Calibration• Phosgene Bottled Cal Gas Not Easily Available• Permeation Tube Device Eliminates Gas Cylinders• Mounted Near Analyzer in Climate-Controlled Box
ProTech903™ D2Tape Analyzer for Phosgene
[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. August 2019 | Specifications Subject to Change Without Notice
ProTech903™ D2
-
ProTech903™ D2Tape Analyzer for Phosgene
[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. August 2019 | Specifications Subject to Change Without Notice
Extended-Life Tape With No Interferences Convenient Permeation Tube Calibration
Secure Remote Access With Advanced DiagnosticsLarge Local Display With LED Indicators
-
ProTech Introduction• Tape Technology for Gas-Phase Samples• Manufactured In & Supported From Calgary, AB• Backed by 40 Years of Experience in Natural Gas
Rapid Return-On-Investment• Never Miss Unexpected Upset• Guaranteed Contractual Compliance• Ensure Product Quality Specifications
Measurement Certainty• 0.005 ppm LDL Every 3 Minutes• Predictive Alarm in ≤ 20 Seconds• 10 Months Data Logging Storage• CSA Class 1 Div. 2 Certified
Key Applications• Polymer Production• Pesticides Manufacturing• Polyurethane Toluene Diisocyanate Synthesis
On-Board Calibration• Phosgene Bottled Cal Gas Not Easily Available• Permeation Tube Device Eliminates Gas Cylinders• Mounted Near Analyzer in Climate-Controlled Box
ProTech903™ W Tape Analyzer for Phosgene
[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. August 2019 | Specifications Subject to Change Without Notice
ProTech903™ W
-
ProTech903™ W Tape Analyzer for Phosgene
[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. August 2019 | Specifications Subject to Change Without Notice
Extended-Life Tape With No Interferences Convenient Permeation Tube Calibration
Secure Remote Access With Advanced DiagnosticsLarge Local Display With LED Indicators
Brochure_Phosgene_ProTech903D1-CEBrochure_Phosgene_ProTech903D2Brochure_Phosgene_ProTech903W