Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the...
Transcript of Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the...
![Page 1: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/1.jpg)
![Page 2: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/2.jpg)
Properties of
DISINFECTANTS
![Page 3: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/3.jpg)
Disinfectants used in potable water must meet the
following requirements:
• Provide Pathogen-Free Water
• Minimize DBP Formation
• Provide Residual Disinfectant to Control Re-growth
This may require the use of a primary and
secondary disinfectant.
Disinfectant Requirements
![Page 4: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/4.jpg)
Primary Disinfectant:
• Achieve the Necessary CT
• Meet Microbial Inactivation Limits
• Meet DBP Limits
Secondary Disinfectant:
• Maintain Residual Concentration in the
Distribution Systems
Primary / Secondary Disinfectant Requirements
![Page 5: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/5.jpg)
TOC Concentration: High TOC may have a
potential for DBP formation. What qualifies?
• TOC > 2.0 ppm, or
• TTHM > 0.08 ppm, or
• HAA5 > 0.06 ppm
Bromide Ion Concentration: Some oxidants
convert bromide to DBP. What qualifies?
• [Br-] > 0.10 ppm
Primary Disinfectant Considerations
![Page 6: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/6.jpg)
Assimilable Organic Carbon (AOC): AOC is
produced when TOC is high and a strong oxidant
is used as a primary disinfectant. What
qualifies?
• AOC > 0.10 ppm post-filtration
DBP Formation Potential: the amount of organic
by-products that may form if chlorine is used.
What qualifies?
• TTHM > 0.08 ppm (7 day formation)
• HAA5 > 0.06 ppm (7 day formation)
Secondary Disinfectant Considerations
![Page 7: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/7.jpg)
Distribution Detention Time: Booster stations
my be required if retention time is too high.
What qualifies?
• > 48 hour retention time
Secondary Disinfectant Considerations
![Page 8: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/8.jpg)
Water-Borne
Pathogens
![Page 9: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/9.jpg)
Bacteria:
• Single-celled organisms
• 0.1 to 10 μm in size
• Spheroid, Rod, Spiral, or Filamentous
Viruses:
• Organisms with DNA/RNA and protein coat
• Dependent on host for replication
• 0.01 to 0.1 μm in size
Water-Borne Pathogens
![Page 10: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/10.jpg)
Protozoa:
• Single-celled organism w/o cell wall
• Most are free-living (exist on their own)
• Some are parasitic (live on a host organism)
Water-Borne Pathogens
![Page 11: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/11.jpg)
Water-Borne Pathogens
![Page 12: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/12.jpg)
Most Common Water-Borne Outbreaks:
• E. coli (bacteria)
• Giardia lamblia (protozoan)
• Cryptosporidium (protozoan)
(Milwaukee, WI 1993: coagulation/filtration failure)
• Legionella pneumophila (bacteria)
(Philadelphia, 1976)
• Cruise ships are the latest cases of Legionella
and E. coli outbreaks
• Naegleria fowleri (amoeba)
Water-Borne Pathogens
![Page 13: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/13.jpg)
Chlorine is primarily used for disinfection but
has other useful purposes:
• Minimize DBPs: (KMnO4/O3 at head works)
• Control Asiatic Clams / Zebra Mussels
• Iron / Manganese Removal
• Prevent Regrowth in Distribution System
• Taste / Odor Removal
• Improve Coagulation & Filter Efficiency
• Prevent Algae Growth in Basins & Filters
• Remove Color
Other Uses of Disinfectants
![Page 14: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/14.jpg)
The History of
CHLORINE
![Page 15: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/15.jpg)
5000 BCEgyptians used the sun to bleach linens
History of Chlorine: Unintended Consequence?
![Page 16: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/16.jpg)
3000 BCMixture of wood ashes and water created
lye, which would lighten colors
History of Chlorine: Unintended Consequence?
![Page 17: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/17.jpg)
History of Chlorine: Unintended Consequence?
1100 ADDutch become experts in laundering; adding
sour milk to lye minimizes disintegration of
linens.
![Page 18: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/18.jpg)
History of Chlorine: Unintended Consequence?
1746John Roebuck adds dilute acid instead of
sour milk. This cuts bleaching time from 24 to
12 hours.
![Page 19: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/19.jpg)
History of Chlorine: Unintended Consequence?
1774Karl Wilhelm Scheele discovers chlorine gas by
mixing pyrolusite (MnO2) with hydrochloric acid
(HCI). He thinks the gas is an oxide of HCI. He
finds that it destroys vegetable color.
![Page 20: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/20.jpg)
History of Chlorine: Unintended Consequence?
1774Karl Wilhelm Scheele discovers chlorine gas by mixing
pyrolusite (MnO2) with hydrochloric acid (HCI). He thinks the
gas is an oxide of HCI. He finds that it destroys vegetable
color.
In 1810, Humphry Davy proves this is elemental
chlorine.
![Page 21: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/21.jpg)
History of Chlorine: Unintended Consequence?
1785Claude Berthollet utilizes chlorine in his
bleaching process.
![Page 22: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/22.jpg)
History of Chlorine: Unintended Consequence?
1799Charles Tennant introduces a chloride of lime
called “bleaching powder”
![Page 23: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/23.jpg)
1854 : John Snow & the Broad Street Pump
Dr. John Snow identifies the source of a cholera
epidemic in London’s Soho District as contaminated
drinking water.
Snow uses chlorine to disinfect the pump and
removes the handle, ending the epidemic and
demonstrating that public water supplies
can be a source of disease.
History of Chlorine: as a Disinfectant
![Page 24: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/24.jpg)
1888 : Chlorination System Patented
The first American patent on “Chlorination of Water”
is granted to Albert R. Leeds, chemistry professor
at Stevens Institute of Technology in Hoboken New
Jersey.
History of Chlorine: as a Disinfectant
![Page 25: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/25.jpg)
1902 : Water Chlorination
The world’s first permanent drinking water
chlorination plant is operated in Middlekerke,
Belgium.
History of Chlorine: as a Disinfectant
![Page 26: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/26.jpg)
1908 : “Chick’s Law of Disinfection”
Harriette Chick identifies the relationship between
germ kill and contact time with a disinfectant.
“Chick’s Law” remains the foundation for
evaluating disinfection efficacy.
History of Chlorine: as a Disinfectant
![Page 27: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/27.jpg)
1908 : Chicago’s Union Stockyard
George A. Johnson adds chlorine to water drawn
from Bubbly Creek, a drinking water source for
livestock in the Union Stockyards, as animals fail to
gain weight after drinking from it. Bubbly Creek is so
named due to gas generated by decaying meat-
processing waste. After being filtered and
chlorinated, Bubbly Creek water
quality surpasses Chicago
city water quality.
History of Chlorine: as a Disinfectant
![Page 28: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/28.jpg)
1908 : Jersey City Water Supply
The City is plagued with typhoid fever & cholera, and
requires the Water Co. to install sewers to prevent
“manure field” run-off from entering water supply. Dr.
John Leal recommends filtration and a low concen-
tration of chlorine to lower bacteria counts.
Jersey City becomes the first U.S. city to
adopt permanent chlorination of
its water supply.
History of Chlorine: as a Disinfectant
![Page 29: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/29.jpg)
1909 : Annual AWWA Meeting
Leal & Johnson present data that supports the
effectiveness of drinking water chlorination. The
cost is 14¢ per million gallons of drinking water.
History of Chlorine: as a Disinfectant
![Page 30: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/30.jpg)
1914: First U.S. Drinking Water Standards
U.S. Public Health Service sets the first standard
regulating bacterial levels in drinking water.
The Department of Treasury calls for all water to
be disinfected with chlorine by 1918.
History of Chlorine: as a Disinfectant
![Page 31: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/31.jpg)
1906 – 1926: Typhoid Fever Death Rate Drops 92%
History of Chlorine: as a Disinfectant
Ra
tes
Pe
r 1
00
,00
0 P
op
ula
tio
n
Source: U.S. Centers for Disease Control & Prevention, Summary of
Notifiable Diseases, 1997.
![Page 32: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/32.jpg)
1997 : Life Magazine
“The filtration of drinking water and the use of
chlorine is probably the most significant public
health advance of the millennium”
History of Chlorine: as a Disinfectant
![Page 33: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/33.jpg)
CHLORINE Safety
![Page 34: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/34.jpg)
Chlorine gas (Cl2) is a greenish-yellow and is
about 1.5 times more dense than air.
What is Chlorine?
![Page 35: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/35.jpg)
Chlorine gas (Cl2) is a greenish-yellow and is about 1.5
times more dense than air.
Chlorine gas can be liquefied by either lowering the
temperature or increasing the pressure, or a
combination of both.
What is Chlorine?
![Page 36: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/36.jpg)
Chlorine gas (Cl2) is a greenish-yellow and is about 1.5
times more dense than air.
Chlorine gas can be liquefied by either lowering the
temperature or increasing the pressure, or a combination
of both.
Liquid chlorine is a clear, amber-colored fluid, which
is about 2.5 times more dense than water.
What is Chlorine?
![Page 37: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/37.jpg)
Chlorine Toxicity
![Page 38: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/38.jpg)
Chlorine Toxicity
![Page 39: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/39.jpg)
Chlorine Toxicity
![Page 40: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/40.jpg)
Chlorine is a toxic chemical that is irritant to
living tissue.
Chlorine Inhalation
![Page 41: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/41.jpg)
Chlorine is a toxic chemical that is irritant to living tissue.
Chlorine is a particularly strong irritant to mucous
membranes and the respiratory system.
Inhalation can cause severe irritation to the
respiratory tract.
Chlorine Inhalation
![Page 42: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/42.jpg)
Chlorine is a toxic chemical that is irritant to living tissue.
Chlorine is a particularly strong irritant to mucous
membranes and the respiratory system. Inhalation can
cause severe irritation to the respiratory tract.
Dry chlorine gas causes an immediate reaction
which forces the victim to leave the area
immediately.
Chlorine Inhalation
![Page 43: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/43.jpg)
Chlorine is a toxic chemical that is irritant to living tissue.
Chlorine is a particularly strong irritant to mucous
membranes and the respiratory system. Inhalation can
cause severe irritation to the respiratory tract.
Dry chlorine gas causes an immediate reaction which forces
the victim to leave the area immediately.
Wet chlorine gas is more tolerable, so the victim
unwittingly inhales more chlorine gas, thus causing
greater damage.
Chlorine Inhalation
![Page 44: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/44.jpg)
< 3 ppm: Possible Detection By Smell
Chlorine Toxicity
![Page 45: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/45.jpg)
< 3 ppm: Possible Detection By Smell
3 – 6 ppm: Eye Irritation
Chlorine Toxicity
![Page 46: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/46.jpg)
< 3 ppm: Possible Detection By Smell
3 – 6 ppm: Eye Irritation
15 ppm: Nose & Throat Irritation
Chlorine Toxicity
![Page 47: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/47.jpg)
< 3 ppm: Possible Detection By Smell
3 – 6 ppm: Eye Irritation
15 ppm: Nose & Throat Irritation
30 ppm: Difficulty Breathing
Chlorine Toxicity
![Page 48: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/48.jpg)
< 3 ppm: Possible Detection By Smell
3 – 6 ppm: Eye Irritation
15 ppm: Nose & Throat Irritation
30 ppm: Difficulty Breathing
400 ppm: Fatal (30 minutes)
Chlorine Toxicity
![Page 49: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/49.jpg)
< 3 ppm: Possible Detection By Smell
3 – 6 ppm: Eye Irritation
15 ppm: Nose & Throat Irritation
30 ppm: Difficulty Breathing
400 ppm: Fatal (30 minutes)
1000 ppm: Fatal (30 seconds)
Chlorine Toxicity
![Page 50: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/50.jpg)
OSHA PEL (Permissible Exposure Limit) :
0.5 ppm TWA (8 hours); 1.0 ppm STEL (15 minutes)
1.0 ppm CEILING
OSHA IDLH (Immediately Dangerous to Life or Health)
10 ppm
Chlorine Toxicity
![Page 51: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/51.jpg)
Toxic Gas Monitoring Solution
Locate chlorine gas monitor(s) in locations where
chlorine is stored or applied
WARNING contact at 0.5 ppm; ALARM contact at
1.0 ppm
Contacts should be connected to strobe lights and/or
audible horn located outside of confined area
Chlorine Toxicity
![Page 52: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/52.jpg)
CHLORINE Chemistry
![Page 53: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/53.jpg)
Chlorine is a widely used disinfectant because:
• It’s easy to apply
• It’s easy to measure
• It’s easy to control
• It persists reasonably well
• It’s relatively inexpensive
Other forms of disinfectants may be better than
chlorine in one of these categories, but none
surpassed all criteria.
Why Use Chlorine?
![Page 54: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/54.jpg)
Chlorine Dose - Chlorine Demand = Residual Chlorine
Chlorine is added to an aqueous process where it reacts
with other chemicals and organisms. The amount of
chlorine that is added is called the Dose. The amount of
chlorine that is consumed by the process is called the
Demand.
The amount of chlorine that remains un-reacted in the
process is called the Residual.
What is Residual Chlorine?
![Page 55: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/55.jpg)
Chlorine gas reacts with water to form
Hypochlorous Acid
Cl2 + H2O HOCI + H+ + Cl-
The pH levels of drinking water typically drop
from 0.5 to 1.5 pH units during typical operations.
What is Residual Chlorine?
![Page 56: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/56.jpg)
Hypochlorous Acid dissociates into Hydrogen ion and
Hypochlorite ion.
HOCI H+ + OCI-
Sodium hypochlorite or calcium hypochlorite in
solution ionize directly to form hypochlorite ion:
NaOCI Na+ + OCI-
Ca(OCI)2 Ca2+ + 2 OCI-
Free Chlorine = Hypochlorous Acid (HOCl) +
Hypochlorite ion (OCl-)
Chlorine Terminology: Free Chlorine
![Page 57: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/57.jpg)
Hypochlorous Acid reacts with Ammonia to form
Monochloramine.
HOCI + NH3 NH2CI + H2O
Monochloramine can further react with Hypochlorous
Acid to form Dichloramine and Trichloramine.
NH2CI + HOCI NHCI2 + H2O
NHCl2 + HOCI NCl3 + H2O
Monochloramine + Dichloramine + Trichloramine
= Combined Chlorine
Chlorine Terminology: Combined Chlorine
![Page 58: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/58.jpg)
Free Chlorine
Hypochlorous Acid + Hypochlorite Ion
Combined Chlorine
Monochloramine + Dichloramine + Trichloramine
Total Chlorine
Free Chlorine + Combined Chlorine
Chlorine Terminology: Total Chlorine
![Page 59: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/59.jpg)
Some customers will refer to “Monochloramine”
as “Total Chlorine”.
This is due to the DPD test methods that are
used to determine residual chlorine
concentrations.
Free Chlorine kit is used for free, Total Chlorine
kit is used for combined chlorine.
Chlorine Terminology: Total Chlorine Confusion
![Page 60: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/60.jpg)
CHLORINEBased Contact Time (CT)
![Page 61: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/61.jpg)
Research regarding the disinfection properties of
specific chemical-based technologies often
correlate the product of the residual disinfectant
concentration, C (in mg/L), and the residual
disinfectant contact time, T (in minutes), (CT)
values to the log inactivation of pathogens.
The concept of CT in chemical disinfection is the
primary method for determining inactivation
levels.
Contact Time (CT) Values
![Page 62: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/62.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less
time
Contact Time (CT) Values: Variables
![Page 63: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/63.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less time
Chlorine Concentration
Amount of chlorine present that is available for
disinfection
Contact Time (CT) Values: Variables
![Page 64: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/64.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less time
Chlorine Concentration
Amount of chlorine present that is available for disinfection
Time
Amount of retention time is equally important as
concentration of chlorine species
Contact Time (CT) Values: Variables
![Page 65: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/65.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less time
Chlorine Concentration
Amount of chlorine present that is available for disinfection
Time
Amount of retention time is equally important as concentration
of chlorine species
pH
If HOCI is used, the ideal pH range is 7.0 - 7.5
Contact Time (CT) Values: Variables
![Page 66: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/66.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less time
Chlorine Concentration
Amount of chlorine present that is available for disinfection
Time
Amount of retention time is equally important as concentration
of chlorine species
pH
If HOCI is used, the ideal pH range is 7.0 – 7.5
Sunlight
UV destroys HOCI
Contact Time (CT) Values: Variables
![Page 67: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/67.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less time
Chlorine Concentration
Amount of chlorine present that is available for disinfection
Time
Amount of retention time is equally important as concentration
of chlorine species
pH
If HOCI is used, the ideal pH range is 7.0 – 7.5
Sunlight
UV destroys HOCI
Contact Chamber
A closed conduit is preferred with HOCI
Contact Time (CT) Values: Variables
![Page 68: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/68.jpg)
Chlorine Species
HOCl is much better than OCl- as it requires less time
Chlorine Concentration
Amount of chlorine present that is available for disinfection
Time
Amount of retention time is equally important as concentration
of chlorine species
pH
If HOCI is used, the ideal pH range is 7.0 – 7.5
Sunlight
UV destroys HOCI
Contact Chamber
A closed conduit is preferred with HOCI
Adequate Mixing
This ensures disinfectant contacts target organisms
Contact Time (CT) Values: Variables
![Page 69: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/69.jpg)
Higher temperatures and lower pH values (less
than 8) correspond to lower CT requirements to
achieve a given level of inactivation.
Contact Time (CT) Values: Temperature Effects
![Page 70: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/70.jpg)
Higher temperatures and lower pH values (less than 8
correspond to lower CT requirements to achieve a given
level of inactivation.
CT values generally increase by a factor of at
least two to three times for each 10ºC decrease
in temperature
Contact Time (CT) Values: Temperature Effects
![Page 71: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/71.jpg)
Higher temperatures and lower pH values (less than 8
correspond to lower CT requirements to achieve a given
level of inactivation.
CT values generally increase by a factor of at least two to
three times for each 10ºC decrease in temperature
Other factors, such as degree of mixing and
turbidity may also affect CT values for
chlorination.
Contact Time (CT) Values: Temperature Effects
![Page 72: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/72.jpg)
Chlorine Based Technologies – Inactivation Capabilities
TemperatureMeasured in °C
Log Inactivation
2.0 3.0 4.0
pH 6-9 pH 10 pH 6-9 pH 10 pH 6-9 pH 10
0.5 6 45 9 66 12 90
5 4 30 6 44 8 60
10 3 22 4 33 6 45
15 2 15 3 22 4 30
20 1 11 2 16 3 22
25 1 7 1 11 2 15
![Page 73: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/73.jpg)
The pH of water is an important factor in
determining virus and bacteria inactivation since
the HOCl and OCl- proportions change
dramatically over a pH range of 6 - 10.
Contact Time (CT) Values: pH Effects
![Page 74: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/74.jpg)
% Distribution HOCI vs. pH
7
100
pH
4 5 6 8 9 10
% HOCl
90
80
70
60
50
40
30
20
10
0
% OCl-
100
0
![Page 75: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/75.jpg)
The pH of water is an important factor in determining
virus and bacteria inactivation since the HOCl and
OCl- proportions change dramatically over a pH range
of 6 - 10.
The biocidal effectiveness of free chlorine
decreases with an increase in pH.
Contact Time (CT) Values: pH Effects
![Page 76: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/76.jpg)
The pH of water is an important factor in determining
virus and bacteria inactivation since the HOCl and
OCl- proportions change dramatically over a pH range
of 6 - 10.
The biocidal effectiveness of free chlorine decreases
with an increase in pH.
HOCl is 1.5 to 3 times more effective than OCl-
as a disinfectant.
Contact Time (CT) Values: pH Effects
![Page 77: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/77.jpg)
Chlorine Based Technologies – Inactivation Capabilities
TemperatureMeasured in °C
Log Inactivation
2.0 3.0 4.0
pH 6-9 pH 10 pH 6-9 pH 10 pH 6-9 pH 10
0.5 6 45 9 66 12 90
5 4 30 6 44 8 60
10 3 22 4 33 6 45
15 2 15 3 22 4 30
20 1 11 2 16 3 22
25 1 7 1 11 2 15
![Page 78: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/78.jpg)
CHLORAMINATION
![Page 79: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/79.jpg)
The History of
CHLORAMINES
![Page 80: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/80.jpg)
1917Denver Union Water Company adds chloramines to
prevent bacteriological “re-growth” problems.
![Page 81: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/81.jpg)
1917Denver Union Water Company adds chloramines to
prevent bacteriological “re-growth” problems.
1920-36Increased use of chloramines (16% of water utilities)
![Page 82: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/82.jpg)
1917Denver Union Water Company adds chloramines to
prevent bacteriological “re-growth” problems.
1920-36Increased use of chloramines (16% of water utilities)
1940’sDue to ammonia shortage during WWII, use drops to
2.6% of utilities.
![Page 83: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/83.jpg)
1979Total Trihalomethane Rule passes. More utilities
consider chloramines to reduce THMs and DBPs.
![Page 84: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/84.jpg)
1979Total Trihalomethane Rule passes. More utilities
consider chloramines to reduce THMs and DBPs.
1990’s20% of surface water plants use chloramines as
secondary disinfectant (Free Chlorine as primary).
![Page 85: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/85.jpg)
1979Total Trihalomethane Rule passes. More utilities
consider chloramines to reduce THMs and DBPs.
1990’s20% of surface water plants use chloramines as
secondary disinfectant (Free Chlorine as primary).
2000’s33% of plants serving >100,000 people use
chloramine.
![Page 86: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/86.jpg)
Future ProjectionAWWA Publication on Chlorination and
Chloramination Practices predicts:
65% of surface water plants serving will use
chloramination.
![Page 87: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/87.jpg)
Future ProjectionAWWA Publication on Chlorination and
Chloramination Practices predicts:
65% of surface water plants serving will use
chloramination.
50% of plants serving <10,000 people will switch
from free chlorine to chloramines for distribution
system residual.
![Page 88: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/88.jpg)
Chloramine is widely used as a secondary
disinfectant because:
• Chloramines are not as reactive with organics as
free chlorine in forming THMs.
Why Use Chloramine?
![Page 89: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/89.jpg)
Chloramine is widely used as a secondary
disinfectant because:
• Chloramines are not as reactive with organics as
free chlorine in forming THMs.
• Monochloramine residual is more stable and
longer lasting than free chlorine.
Why Use Chloramine?
![Page 90: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/90.jpg)
Chloramine is widely used as a secondary
disinfectant because:
• Chloramines are not as reactive with organics as
free chlorine in forming THMs.
• Monochloramine residual is more stable and
longer lasting than free chlorine.
• Monochloramine is more effective in controlling
biofilm in distribution system.
Why Use Chloramine?
![Page 91: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/91.jpg)
Chloramine is widely used as a secondary
disinfectant because:
• Chloramines are not as reactive with organics as
free chlorine in forming THMs.
• Monochloramine residual is more stable and
longer lasting than free chlorine.
• Monochloramine is more effective in controlling
biofilm in distribution system.
• Monochloramine produces less taste and odor
problems.
Why Use Chloramine?
![Page 92: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/92.jpg)
CHLORAMINE Chemistry
![Page 93: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/93.jpg)
Chloramine is widely used as a secondary
disinfectant because:
• Chloramines are not as reactive with organics as
free chlorine in forming THMs.
Why Use Chloramine?
![Page 94: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/94.jpg)
Chloramine is widely used as a secondary
disinfectant because:
• Chloramines are not as reactive with organics as
free chlorine in forming THMs.
• Monochloramine residual is more stable and
longer lasting than free chlorine.
Why Use Chloramine?
![Page 95: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/95.jpg)
Weight Based Units of Measure
ATOMATOMIC
WEIGHTMOLECULE
MOLECULAR
WEIGHT
Cl 35.5 Cl2 71
N 14 NH3 17
H 1 NH2Cl 51
NHCl2 85
NCI3 129
![Page 96: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/96.jpg)
For Cl2 : NH3
71 lbs Cl2 is required for every 17 lbs of NH3
71 lbs Cl2 4.2 lbs Cl2------------------------------------ = -----------------------------------
17 lbs NH3 1.0 lb NH3
Weight Based Ratios
![Page 97: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/97.jpg)
For Cl2 : NH3
71 lbs Cl2 is required for every 17 lbs of NH3
71 lbs Cl2 4.2 lbs Cl2------------------------------------- = -------------------------------------
17 lbs NH3 1.0 lb NH3
Weight Based Ratios
For Cl2 : NH3 - N
71 lbs Cl2 is required for every 14 lbs of N
71 lbs Cl2 5.06 lbs Cl2-------------------------------------- = ----------------------------------------
14 lbs N 1.0 lb N
![Page 98: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/98.jpg)
Cl2 : NH3 < 4.2:1
NH2Cl formed
Excess NH3 present after the reaction
Cl2 : NH3 Ratio
![Page 99: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/99.jpg)
NCl
O
Monochloramine Formation
HOCI + NH3 NH2Cl + H2O
H
+ N
H
HH
Cl
H
H+ O
H
H
Hypochlorous + Ammonia Monochloramine + Water
Acid
![Page 100: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/100.jpg)
Cl2 : NH3 < 4.2:1
NH2Cl formed
Excess NH3 present after the reaction
Cl2 : NH3 > 4.2:1
Excess Cl2 is used
NHCl2 and NCl3 are formed
Cl2 : NH3 Ratio
![Page 101: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/101.jpg)
NCl
O
Dichloramine Formation
HOCI + NH2Cl NHCl2 + H2O
H
+
Cl
H
H+ O
H
H
Hypochlorous + Monochloramine Dichloramine + Water
Acid
N
ClH
Cl
![Page 102: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/102.jpg)
NCl
O
Trichloramine Formation
HOCI + NHCl2 NCl3 + H2O
H
+
ClH+ O
H
H
Hypochlorous + Dichloramine Trichloramine + Water
Acid
N
Cl
Cl
Cl
Cl
![Page 103: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/103.jpg)
Other factors must be considered when
determining optimal ratio:
• pH
• Temperature
• Chlorine Demand
• Competing Reactions
• Reaction Time
• Chloramine Decay
Practical Conditions that Affect Ratio
![Page 104: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/104.jpg)
pH Influence on Chloramine Formation
% o
f TA
C R
ea
din
g
100
50
0
4 6 8 10
pH
At pH > 5.5, NH2Cl dominates
NH2Cl formation is optimized at pH > 8.2
NHCl2
NH2Cl
NCl3
![Page 105: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/105.jpg)
Decay can result from:
• Auto-decomposition
(lower pH = faster decay)
Chloramine Decay
![Page 106: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/106.jpg)
pH ≤ 11:
3 NH2Cl ⟶ N2 + NH4Cl + 2 HCl
pH > 11:
3 NH2Cl + 3 OH−⟶ NH3 + N2 + 3 Cl− + 3 H2O
pH 4:
2 NH2Cl + H+⟺ NHCl2 + NH4+
pH 3:
3 NHCl2 + H+⟺ 2 NCl3 + NH4+
NHCl2 + NCl3 + 2 H2O ⟶ N2 + 3 HCl + 2 HOCl
Chloramine Decay
![Page 107: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/107.jpg)
Decay can result from:
• Auto-decomposition
(lower pH = faster decay)
• Oxidation of Natural Organic Matter
(more NOM = faster decay)
Chloramine Decay
![Page 108: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/108.jpg)
Decay can result from:
• Auto-decomposition
(lower pH = faster decay)
• Oxidation of Natural Organic Matter
(more NOM = faster decay)
• Consumption by Nitrifying Bacteria
(more free ammonia = more bacteria =
faster decay)
Chloramine Decay
![Page 109: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/109.jpg)
Decay can result from:
• Auto-decomposition
(lower pH = faster decay)
• Oxidation of Natural Organic Matter
(more NOM = faster decay)
• Consumption by Nitrifying Bacteria
(more free ammonia = more bacteria = faster decay)
• Oxidation of Iron and Other Distribution
Materials
(more demand = faster decay)
Chloramine Decay
![Page 110: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/110.jpg)
1. One molecule of Free Chlorine reacts with
one molecule of Free Ammonia to form
one molecule of Monochloramine.
Chloramination Facts:
![Page 111: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/111.jpg)
1. One molecule of Free Chlorine reacts with one
molecule of Free Ammonia to form one molecule
of Monochloramine.
2. Free Chlorine and Free Ammonia cannot
co-exist to any significant degree.
Chloramination Facts:
![Page 112: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/112.jpg)
1. One molecule of Free Chlorine reacts with one
molecule of Free Ammonia to form one molecule
of Monochloramine.
2. Free Chlorine and Free Ammonia cannot co-exist
to any significant degree.
3. Free Chlorine and Monochloramine
cannot co-exist to any significant degree.
Chloramination Facts:
![Page 113: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/113.jpg)
1. One molecule of Free Chlorine reacts with one
molecule of Free Ammonia to form one molecule of
Monochloramine.
2. Free Chlorine and Free Ammonia cannot co-exist
to any significant degree.
3. Free Chlorine and Monochloramine cannot co-
exist to any significant degree.
4. If the ratio is correct, the monochloramine
concentration will remain constant.
Chloramination Facts:
![Page 114: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/114.jpg)
1. One molecule of Free Chlorine reacts with one
molecule of Free Ammonia to form one molecule
of Monochloramine.
2. Free Chlorine and Free Ammonia cannot co-
exist to any significant degree.
3. Free Chlorine and Monochloramine cannot co-
exist to any significant degree.
4. If the ratio is correct, the Monochloramine
concentration will remain constant.
5. An incorrect ratio will result in excess
Free Ammonia or the destruction of
Monochloramine
Chloramination Facts:
![Page 115: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/115.jpg)
Breakpoint Chlorination Curve
1. Chlorine is consumed by readily oxidizable compounds (iron
manganese, nitrite, sulfide, etc.). Little to no residual chlorine present.
![Page 116: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/116.jpg)
Breakpoint Chlorination Curve
2. Chlorine reacts with nitrogen in water. Monochloramine is formed
(assuming conditions are met). Residual chlorine concentration increases.
![Page 117: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/117.jpg)
Breakpoint Chlorination Curve
3. Optimal zone for monochloramine production. Correct ratio is achieved.
![Page 118: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/118.jpg)
Breakpoint Chlorination Curve
4. Ratio is exceeded and monochloramine is being consumed to form
dichloramine and trichloramine.
![Page 119: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/119.jpg)
Breakpoint Chlorination Curve
5. BREAKPOINT. Almost all of the nitrogen is in di- or trichloramine form.
Monochloramine is no longer present. Free chlorine residual begins to appear.
![Page 120: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/120.jpg)
Breakpoint Chlorination Curve
6. Free chlorine residual increases. Combined chlorine concentration is
unchanged as all nitrogen is in di- or trichloramine form.
![Page 121: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/121.jpg)
RESIDUAL CHLORINE
Regulations
![Page 122: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/122.jpg)
Disinfection Byproducts (DBP) Rule
Sets limits for disinfectant residuals
• Free chlorine and chloramines
• Maximum Residual Disinfectant Level - 4.0 mg/L
• Minimum residual concentration entering
distribution –
0.2 mg/L for free chlorine, 0.5 mg/L for
chloramine
• Must maintain a residual throughout distribution
USEPA Regulations
![Page 123: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/123.jpg)
Disinfection Byproducts (DBP) Rule
Sets limits for disinfectant residuals
• Free chlorine and chloramines
• Maximum Residual Disinfectant Level - 4.0 mg/L
• Minimum residual concentration entering distribution –
0.2 mg/L for free chlorine, 0.5 mg/L for chloramine
• Must maintain a residual throughout distribution
Sets limits for disinfection byproducts
• Trihalomethanes (THMs) - 0.080 mg/L
• Haloacetic acids (HAAs) - 0.060 mg/L
• Bromate ion - 0.010 mg/L
USEPA Regulations
![Page 124: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/124.jpg)
GWSs Serving More Than 3,300 People
GWSs serving more than 3,300 people
conducting compliance monitoring must monitor
the residual disinfectant concentration
continuously, record the lowest daily residual
disinfectant concentration, and maintain the
state-determined minimum disinfectant residual
concentration for each day the water is served
to the public.
Ground Water Rule
![Page 125: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/125.jpg)
The USEPA neither approves nor
recommends monitors for specific
parameters.
USEPA Approvals / Recommendations
![Page 126: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/126.jpg)
The USEPA neither approves nor recommends
monitors for specific parameters.
The USEPA approves methodologies for
monitoring specific parameters (Standard
Methods).
USEPA Approvals / Recommendations
![Page 127: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/127.jpg)
The USEPA neither approves nor recommends
monitors for specific parameters.
The USEPA approves methodologies for monitoring
specific parameters (Standard Methods).
The EPA recently approved the first method
for on-line monitoring of residual chlorine.
USEPA Approvals / Recommendations
![Page 128: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/128.jpg)
This method for On-Line Chlorine Monitors
was approved in September 2009.
This method allows the use of any type of
on-line chlorine analyzer for compliance
monitoring when used in conjunction with a
grab sample reference method that is
approved for drinking water compliance
monitoring.
USEPA Method 334.0
![Page 129: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/129.jpg)
• This method is for the analysis of residual
chlorine (free or total) in drinking water. It is
primarily intended to be used by drinking
water utilities for compliance with daily
monitoring requirements.
USEPA Method 334.0: Scope of Method
![Page 130: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/130.jpg)
• This method is for the analysis of residual
chlorine (free or total) in drinking water. It is
primarily intended to be used by drinking water
utilities for compliance with daily monitoring
requirements.
• This method allows the use of any type
of on-line chlorine analyzer for
compliance monitoring when used in
conjunction with a grab sample
reference method that is approved for
drinking water compliance monitoring.
USEPA Method 334.0: Scope of Method
![Page 131: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/131.jpg)
• This method is for the analysis of residual
chlorine (free or total) in drinking water. It is
primarily intended to be used by drinking water
utilities for compliance with daily monitoring
requirements.
• This method allows the use of any type of on-line
chlorine analyzer for compliance monitoring
when used in conjunction with a grab sample
reference method that is approved for drinking
water compliance monitoring.
• This method is intended to be used
when chlorine residuals (free or total)
are in the range of 0.2 mg/L to 4 mg/L.
USEPA Method 334.0: Scope of Method
![Page 132: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/132.jpg)
• The instrument is calibrated using aqueous
standards or the results from paired grab
samples that are collected at the same
sample point and time.
USEPA Method 334.0: Summary of Method
![Page 133: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/133.jpg)
• The instrument is calibrated using aqueous
standards or the results from paired grab samples
that are collected at the same sample point and
time.
• The grab samples are analyzed for chlorine
(free or total) using a method that is
approved for drinking water compliance
monitoring.
USEPA Method 334.0: Summary of Method
![Page 134: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/134.jpg)
• Consideration for changes in water pH,
temperature, ionic strength, and
interferences (iron, manganese, copper,
etc.).
Chlorine Monitor Selection Requirements
![Page 135: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/135.jpg)
• Consideration for changes in water pH,
temperature, ionic strength, and interferences
(iron, manganese, copper, etc.).
• Concentration range should be as small
as possible yet still bracket the expected
concentrations. (0 - 2.000 ppm range
for 0.5 - 1.5 ppm residual)
Chlorine Monitor Selection Requirements
![Page 136: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/136.jpg)
• Consideration for changes in water pH,
temperature, ionic strength, and interferences
(iron, manganese, copper, etc.).
• Concentration range should be as small as
possible yet still bracket the expected
concentrations.
(0 - 2.000 ppm range for 0.5 - 1.5 ppm residual)
• The instrument must be installed so
changes in pressure and flow rate do not
influence the measurement.
Chlorine Monitor Selection Requirements
![Page 137: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/137.jpg)
• The analyzer must have a readout at its
installation location and the readings
must be continually recorded.
Chlorine Monitor Requirements
![Page 138: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/138.jpg)
• The analyzer must have a readout at its
installation location and the readings must be
continually recorded.
• For remote installations, there should be
a capability to transmit the data to a
centralized location.
Chlorine Monitor Requirements
![Page 139: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/139.jpg)
• The analyzer must have a readout at its
installation location and the readings must be
continually recorded.
• For remote installations, there should be a
capability to transmit the data to a centralized
location.
• The analyzer should have an alarm to
activate when the chlorine concentration
is outside normal range.
Chlorine Monitor Requirements
![Page 140: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/140.jpg)
• The analyzer must have a readout at its
installation location and the readings must be
continually recorded.
• For remote installations, there should be a
capability to transmit the data to a centralized
location.
• The analyzer should have an alarm to activate
when the chlorine concentration is outside
normal range.
• The analyzer must allow manual
adjustment for calibration.
Chlorine Monitor Requirements
![Page 141: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/141.jpg)
In order to be compliant with Method 334.0,
your monitor must meet one of the following
criteria:
1. Meet the Initial Demonstration of Capability
(IDC).
USEPA Method 334.0: Does Your Monitor Comply?
![Page 142: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/142.jpg)
In order to be compliant with Method 334.0,
your monitor must meet one of the following
criteria:
1. Meet the Initial Demonstration of Capability
(IDC).
At least 14 days of grab samples must be
compared to the monitor. The monitor reading
must be within ± 0.1 mg/L or ± 15% (whichever
is larger) of the grab sample measurement
without maintenance or calibration adjustment.
USEPA Method 334.0: Does Your Monitor Comply?
![Page 143: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/143.jpg)
In order to be compliant with Method 334.0,
your monitor must meet one of the following
criteria:
1. Meet the Initial Demonstration of Capability
(IDC).
2. The IDC for the on-line chlorine analyzer is not
required if historical operating data for the on-
line chlorine analyzer demonstrate the criterion
are being met on an on-going basis.
USEPA Method 334.0: Does Your Monitor Comply?
![Page 144: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/144.jpg)
13. WASTE MANAGEMENT13.1 The analytical procedures described in this method generate relatively small amounts of waste since only small amounts of reagents are used. The matrices of concern are drinking water. However, the Agency requires that wastemanagement practices be conducted consistent with all applicable rules and regulations, and that the air, water, and land is protected by minimizing and controlling all releases from bench operations. Also, compliance is required with any sewage discharge permits and regulations, particularly the hazardous waste identification rules and land disposal restrictions.
USEPA Method 334.0 : Waste Management
![Page 145: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/145.jpg)
Waste Management
![Page 146: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/146.jpg)
RESIDUAL CHLORINE
Detection Methodologies
![Page 147: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/147.jpg)
Colorimetric Monitor
-vs-
Membraned/Amperometric Sensor
![Page 148: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/148.jpg)
Operating Principle
Reagents (buffer and indicator solution) are added to a known volume of process water.
[Free Chlorine: DPD, Buffer]
[Total Chlorine : DPD, Buffer, KI]
Colorimetric Systems
![Page 149: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/149.jpg)
Operating Principle
Reagents (buffer and indicator solution) are added to a known volume of process water.
At higher concentrations, the Imine is favoredwhich causes the magenta color to fade.
Colorimetric Systems
![Page 150: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/150.jpg)
Operating Principle
Reagents (buffer and indicator solution) are added to a known volume of process water.
After mixing period, measure light transmitted through sample to determine color change. Color intensity is proportional to free chlorine in the sample.
Colorimetric Systems
![Page 151: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/151.jpg)
Advantages
High pH is not a limiting factor
Disadvantages
Uses reagents
Must use pumps, valves and capillary tubes
Can only generate a new residual reading
every 2-1/2 minutes
No pH or temperature output
DPD Interference (Oxidized Mn and Cu;
chloramine in free chlorine measurement;
iodide from total chlorine measurement)
Colorimetric Method
![Page 152: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/152.jpg)
DPD Free Chlorine: Manganese Interference (~ 0.3 ppm Mn)
![Page 153: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/153.jpg)
DPD Free Chlorine: Monochloramine Interference
![Page 154: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/154.jpg)
Operating Principle
A sensor consisting of a membrane (which allows HOCl to migrate through it), two metal electrodes, and an electrolyte are in contact with the process water.
Membraned-Amperometric Sensor
![Page 155: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/155.jpg)
Operating Principle
A sensor consisting of a membrane (which allows HOCl to migrate through it), two metal electrodes, and an electrolyte are in contact with the process water.
HOCl migrates through the membrane and is reduced at the cathode.
Membraned-Amperometric Sensor
![Page 156: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/156.jpg)
Operating Principle
A sensor consisting of a membrane (which allows HOCl to migrate through it), two metal electrodes, and an electrolyte are in contact with the process water.
HOCl migrates through the membrane and is reduced at the cathode.
The current generated from this reaction is proportional to free chlorine concentration.
Membraned-Amperometric Sensor
![Page 157: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/157.jpg)
Operating Principle
A sensor consisting of a membrane (which allows HOCl to migrate through it), two metal electrodes, and an electrolyte are in contact with the process water.
HOCl migrates through the membrane and is reduced at the cathode.
The current generated from this reaction is proportional to free chlorine concentration.
This methodology can be used for Free Chlorine or Combined Chlorine (monochloramine)
Membraned-Amperometric Sensor
![Page 158: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/158.jpg)
Free or Combined Chlorine Sensor
![Page 159: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/159.jpg)
Membraned-Amperometric Sensor
Advantages
Ease of use
No reagents or buffers added
No moving parts
Temperature compensation
Optional pH compensation
pH or temperature output
Disadvantages
Membrane fouling
pH dependent for free chlorine
![Page 160: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/160.jpg)
Iron / Manganes Fouling
When iron / manganese coat the membrane, sensor signal decreases.
Allow iron / manganese to coat the membrane. This may take a few days.
When sensor signal has stabilized, perform a 1-point calibration to “calibrate out” the effect of the coating.
![Page 161: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/161.jpg)
Membraned-Amperometric Sensor
Membraned/Amperometric Sensor Method is
compliant with USEPA Method 334.0 for use
in online residual chlorine monitoring.
![Page 162: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/162.jpg)
DISSOLVED AMMONIA
![Page 163: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/163.jpg)
Breakpoint Chlorination Curve
3. Optimal zone for monochloramine production. Correct ratio is achieved.
![Page 164: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/164.jpg)
Ammonia Chemistry
Ammonia exists in water at normal pH (6-8)
as predominantly as ammonium ion, NH4+
NH4+ NH3 + H+
Fraction of ammonia and ammonium ion as a fraction of pH
6 7 8 9 10 11 12 13 14
100
80
60
40
20
0
% of species
ammonia
ammonium
![Page 165: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/165.jpg)
How is Ammonia Measured?
There are two types of methods that have been used
historically to measure dissolved ammonia.
1. Direct Measurement: Ammonia Selective Electrode
– Direct measurement of NH3
2. Reaction Chemistry – Ammonia reacted with
chemicals to convert it to another measureable form
![Page 166: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/166.jpg)
DIRECT SENSING MONITOR
-vs-
COLORIMETRIC MONITOR
-vs-
MEMBRANED/AMPEROMETRIC SENSOR
![Page 167: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/167.jpg)
Ammonia is detected using
an ammonia selective
electrode.
The sample pH is adjusted
to 11 using a basic solution,
converting ammonium ion
to ammonia.
Ammonia gas permeates
the membrane and
changes pH of fill solution.
pH of fill solution is
measured with an internal
pH sensor.
Direct Ammonia Measurement
![Page 168: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/168.jpg)
The sample is pH adjusted to convert all
ammonium ion to ammonia:
NH4+ + OH- NH3 + H2O
Hypochlorite is added to convert the ammonia to
monochloramine:
NH3 + OCl- NH2Cl + OH-
Monochloramine reacts with Phenate to produce
Indophenol, which has an intense, blue color.
The sample is then analyzed using a colorimeter
to determine concentration.
Colorimetric Ammonia Chemistry
![Page 169: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/169.jpg)
A reagent containing buffered bleach is injected
into the sample.
HOCl + NH4+ + OH- NH2Cl + 2H2O
A second reagent containing hydrogen peroxide
in excess is injected within a few seconds to
quench the chlorine-ammonia reactions.
HOCl + H2O2 H+ + Cl- + H2O + O2
Monochloramine is then measured directly with a
membraned amperometric sensor.
Membraned Sensor Ammonia Chemistry
![Page 170: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/170.jpg)
Free ammonia monitoring requires one sensor to
be located before reagent addition and one after
reagent addition.
Chemistry Module: Free Ammonia
![Page 171: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/171.jpg)
Free ammonia monitoring requires one sensor to be
located before reagent addition and one after reagent
addition.
Sensor 1 measures the existing monochloramine
concentration in the sample.
Chemistry Module: Free Ammonia
![Page 172: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/172.jpg)
Free ammonia monitoring requires one sensor to be
located before reagent addition and one after reagent
addition.
Sensor 1 measures the existing monochloramine
concentration in the sample.
Sensor 2, located after chemical addition,
measures the monochloramine concentration that
is equivalent to total dissolved ammonia
concentration.
Chemistry Module: Free Ammonia
![Page 173: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/173.jpg)
Free ammonia monitoring requires one sensor to be
located before reagent addition and one after reagent
addition.
Sensor 1 measures the existing monochloramine
concentration in the sample.
Sensor 2, located after chemical addition, measures the
monochloramine concentration that is equivalent to total
dissolved ammonia concentration.
The monitor performs the math (Sensor 2 –
Sensor 1) to yield the concentration of free
ammonia.
Chemistry Module: Free Ammonia
![Page 174: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/174.jpg)
TOTAL CHLORINE
![Page 175: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/175.jpg)
Wastewater Plant
Typical Wastewater Treatment Plant
EqualizationBasin
PrimaryClarifier
Aerobic / AnaerobicSludge Digester
Gravity SludgeThickener
SecondaryClarifier
NitrificationBasinAeration Basin
Plant Inlet(Influent)
FinalFiltration
Disinfection
Plant Effluent
Return Activated Sludge (RAS)
Waste Activated Sludge (WAS)
SludgeDewatering
SludgeDisposalSludge
Disposal
Centrate
6
6
![Page 176: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/176.jpg)
Wastewater that is discharged into a natural
waterway must have a total chlorine concentration
below the limit defined in the permit.
Limits vary by region, but the allowable discharge
concentration range is 0.010 to 0.050 ppm.
Ideal reading for a total chlorine monitor is 0.00 ppm.
These units are not meant for process control.
Total Chlorine Discharge Limits
![Page 177: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/177.jpg)
COLORIMETRIC MONITOR
-vs-
MEMBRANED/AMPEROMETRIC SENSOR
![Page 178: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/178.jpg)
Total chlorine detection requires the addition of
reagents, typically acetic acid (vinegar) and
potassium iodide (KI)
Iodide ion reacts with both free and combined
chlorine to form molecular iodine.
HOCl + 2KI + HAc I2 + KCl + KAc + H2O
NH2Cl + 2KI + 2HAc I2 + KCl + KAc + NH4Ac
NHCl2 + 4KI + 3HAc 2l2 + 2KCl + 2KAc + NH4Ac
Total Chlorine Chemistry
![Page 179: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/179.jpg)
RESIDUAL SULFITE
![Page 180: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/180.jpg)
Sulfite ion is the result of the hydrolysis of
sulfur dioxide gas, sodium sulfite, sodium
bisulfite, or sodium metabisulfite.
SO2 + H2O SO3= + 2H+
Na2SO3 2Na+ + SO3=
NaHSO3 Na+ + H+ + SO3=
Na2S2O5 + H2O 2Na+ + 2H+ + 2SO3=
Sources of Sulfite
![Page 181: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/181.jpg)
Strongly reducing sulfite is used to
eliminate chlorine residuals that may be
toxic to aquatic life.
All forms of chlorine react with sulfite ion
and are destroyed in the process
HOCl + H2SO3 HCl + H2SO4
NH2Cl + H2SO3 + H2O NH4Cl + H2SO4
How is Sulfite Used?
![Page 182: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/182.jpg)
Control using residual chlorine very difficult when
limits are set at low PPB levels.
Why Control Dechlorination Using Sulfite
![Page 183: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/183.jpg)
Control using residual chlorine very difficult when limits are
set at low PPB levels.
Chlorine limits often exceeded by the time
chlorine residual monitors respond.
Why Control Dechlorination Using Sulfite
![Page 184: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/184.jpg)
Control using residual chlorine very difficult when limits are
set at low PPB levels.
Chlorine limits often exceeded by the time chlorine residual
monitors respond.
Allows maintenance of a small sulfite residual,
insuring complete dechlorination.
Why Control Dechlorination Using Sulfite
![Page 185: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/185.jpg)
Control using residual chlorine very difficult when limits are
set at low PPB levels.
Chlorine limits often exceeded by the time chlorine residual
monitors respond.
Allows maintenance of a small sulfite residual, insuring
complete dechlorination.
Saves money by reducing excess sulfite usage.
Why Control Dechlorination Using Sulfite
![Page 186: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/186.jpg)
Sulfite (as SO2) reacts with chlorine on a
0.91:1 mass basis, which means it takes
7.59 lbs. of sulfite to remove 1 PPM of
chlorine for each million gallons flow.
Chemical Savings Example
![Page 187: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/187.jpg)
Sulfite (as SO2) reacts with chlorine on a 0.91:1
mass basis, which means it takes 7.59 lbs. of sulfite
to remove 1 PPM of chlorine for each million gallons
flow.
A typical cost for sulfite is about $0.80 per
pound.
Chemical Savings Example
![Page 188: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/188.jpg)
Sulfite (as SO2) reacts with chlorine on a 0.91:1
mass basis, which means it takes 7.59 lbs. of sulfite
to remove 1 PPM of chlorine for each million gallons
flow.
A typical cost for sulfite is about $0.80 per pound.
A simple formula can be used to calculate
saving:
$ Saved = Cost (SO2 / lb.) X Flow (MGD)
X 7.59 lb./PPM X 365 Days
Chemical Savings Example
![Page 189: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/189.jpg)
Sulfite (as SO2) reacts with chlorine on a 0.91:1 mass
basis, which means it takes 7.59 lbs. of sulfite to
remove 1 PPM of chlorine for each million gallons flow.
A typical cost for sulfite is about $0.80 per pound.
A simple formula can be used to calculate saving:
$ Saved = Cost (SO2 / lb.) X Flow (MGD) X 7.59
lb./PPM X 365 Days
Example of first year savings for 10 MGD
plant reducing sulfite excess by 1PPM.
$ Saved = 0.80 X 10 X 7.59 X 365
= $22,162.80
Chemical Savings Example
![Page 190: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/190.jpg)
Continuous sulfite residuals result in the
buildup of sulfur reducing bacteria in analyzer
sample lines.
Sample Line Cleaning Requirements
![Page 191: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/191.jpg)
Continuous sulfite residuals result in the buildup of
sulfur reducing bacteria in analyzer sample lines.
Bacteria in sample lines consume sulfite as it
is traveling to the analyzer, resulting in low
readings.
Sample Line Cleaning Requirements
![Page 192: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/192.jpg)
Continuous sulfite residuals result in the buildup of
sulfur reducing bacteria in analyzer sample lines.
Bacteria in sample lines consume sulfite as it is
traveling to the analyzer, resulting in low readings.
Periodic addition of chlorine in the sample
line can control bacterial growth. Chlorine
levels from 10-50 PPM for 3-5 minutes daily
helps control the problem.
Sample Line Cleaning Requirements
![Page 193: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/193.jpg)
DO YOU HAVE ANY
QUESTIONS?
![Page 194: Properties of DISINFECTANTS - WordPress.com · Disinfectants used in potable water must meet the following requirements: • Provide Pathogen-Free Water • Minimize DBP Formation](https://reader030.fdocuments.in/reader030/viewer/2022040507/5e467bdbb6f43d63fc177ee5/html5/thumbnails/194.jpg)
Analytical Technology, Inc.www.AnalyticalTechnology.com
800-959-0299
The Spectrum Groupwww.TheSpectrumGroup.com
1-504-561-6000