€¦ · Project Manager Project Engineer ELECTRICAL SHEET LIST Sheet Number Sheet Title PROJECT...
Transcript of €¦ · Project Manager Project Engineer ELECTRICAL SHEET LIST Sheet Number Sheet Title PROJECT...
5570 East Yale Avenue
Denver, CO 80222Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,
Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,
Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
E00
ELECTRICAL
GENERAL
INFORMATION
ABBREVIATIONS AND DESCRIPTIONS
POWER
ONE-LINE DIAGRAMS
GROUNDING/LIGHTNING
SYSTEMS
ELECTRICAL LEGEND
BCER CONTACT LIST
Arvada Office Colorado Springs Office
Project Manager Project Engineer
ELECTRICAL SHEET LIST
Sheet Number Sheet Title
PROJECT NARRATIVE
5570 East Yale Avenue
Denver, CO 80222
Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,
Suite 400
Colorado Springs, Co. 80921
719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,
Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
E01
ELECTRICAL
ONE-LINE
DIAGRAM
5570 East Yale Avenue
Denver, CO 80222Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,
Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,
Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
E10
ELECTRICAL
SITE PLAN
TITLESHEET#
*
KEYNOTE
DRAWING NOTE
EQUIPMENT SCHEDULE ID
REVISION NUMBER
ENLARGED FOOR PLAN, SCHEDULE, OR DETAIL CALLOUT
DESCRIPTIONSYMBOL
#
REFERENCE INDICATOR
REFERENCE SHEET NUMBER
REFERENCE TAG
*
#
REFERENCE INDICATOR
REFERENCE DRAWING NUMBER
ROOM WALL ELEVATION CALLOUT
#
A,B,C,D WALL ELEVATION REFERENCE
REFERENCE SHEET NUMBER
BREAK LINE
DETAIL FURNISH / INSTALL CALLOUT (ON DETAILS WHERE CALLOUTS
ARE USED, ASSUME EC FOR X AND Y WHERE NOT INDICATED FOR
COMPONENTS) UON IN TECHNOLOGY RESPONSIBILITY MATRIX)
X INDICATES ENTITY (ABBREVIATED) RIMROCK RECOMMENDS BE
RESPONSIBLE FOR FURNISHING
Y INDICATES ENTITY (ABBREVIATED) RIMROCK RECOMMENDS BE
RESPONSIBLE FOR INSTALLING
CONTINUANCE LINE
TELECOM AREA BOUNDARY LINE
TELECOM ROOM BOUNDARY LINE
XY
TYPICAL STATION CALLOUT
X INDICATES NUMBER OF VOICE/DATA PORTS/CABLES
Y INDICATES NUMBER OF COAX PORTS/CABLES
(ASSUME 0 IF BLANK)
+H
TYPICAL DEVICE OR EQUIPMENT NON-STANDARD HEIGHT
(TELECOM OUTLET EXAMPLE SHOWN)
H INDICATES DIMENSION OF DEVICE OR EQUIPMENT
CENTERLINE (UON) ABOVE FINISHED FLOOR
TYPICAL ASSEMBLY NOTATION, INCLUDES:
- INFRASTRUCTURE: FLOOR BOX, POKE-THRU, WALL BOX,
SURFACE RACEWAY, ENCLOSURE, HOUSING, RACK, ETC.
- SERVICES: DEVICES AND/OR CABLING AS
SHOWN ASSOCIATED WITH INFRASTRUCTURE.
(FLOORBOX WITH INTERFACE PLATE AND
TELECOM OUTLET EXAMPLE SHOWN).
2
A
WALL
SYMBOL/DEVICE CONGESTION NOTATION INCLUDES:
LEADER INDICATOR: USED TO IDENTIFY INTENDED
LOCATION OF SYMBOL(S) THAT WOULD OTHERWISE
OVERLAP OR CREATE CONGESTION WITH OTHER
SYMBOLOGY.
TARGET INDICATOR: USED TO IDENTIFY INTENDED
LOCATION OF LEADER ARROWHEAD TERMINATION THAT
WOULD OTHERWISE OVERLAP OR CREATE CONGESTION
WITH OTHER SYMBOLOGY.
CONGESTION INDICATOR: USED TO IDENTIFY
ARRANGEMENT OF CONGESTED DEVICES.
X INDICATES CONGESTION TYPE:
H HORIZONTAL
V VERTICAL (ALONG SAME STUD OR STUD CAVITY)
B BOTH HORIZONTAL AND VERTICAL
-- SINGLE ITEM (NOT ALIGNED)
2
X
FUTURE EQUIPMENT, RACK, OR ENCLOSURE OUTLINE
NOT ALL ITEMS LISTED IN THIS LEGEND ARE USED ON TECHNOLOGY DRAWINGS.
SUBSCRIPTS ADJACENT SYMBOLS ELSEWHERE ON DRAWINGS INDICATE ADDITIONAL INFORMATION REGARDING APPLICATION
OF DEVICE OR EQUIPMENT. REFER TO ABBREVIATIONS, DRAWING ANNOTATIONS, SCHEDULES, AND SPECIFICATIONS FOR
ADDITIONAL SYMBOL SUBSCRIPT INFORMATION.
MULTIPLE SUBSCRIPTS ADJACENT A SYMBOL SIGNIFY MULTIPLE DEVICE TYPES OR MULTIPLE INSTALLATION REQUIREMENTS
FOR ONE OR MORE DEVICES. MULTIPLE SUBSCRIPTS REPRESENTING DIFFERENT DEVICE TYPES ADJACENT A SYMBOL IS
EQUIVALENT TO MULTIPLE DEVICES LOCATED AT THE SAME OR APPROXIMATE PLAN LOCATION, BUT AT DIFFERENT
ELEVATIONS. THE FIRST SUBSCRIPTS (STARTING FROM THE LEFT OR TOP) IS ASSOCIATED WITH THE DEVICE AT THE HIGHEST
ELEVATION, THE SECOND SUBSCRIPT IS ASSOCIATED WITH THE DEVICE AT THE NEXT HIGHEST ELEVATION, ETC.
1.
2.
3.
*
2
#
#
#
#
X Y
A
S
IFIF
X
A
XX##
(XX##)
TYPICAL WALL MOUNTED DEVICE NOTATION. EXAMPLE:
CEILING-MOUNTED SPEAKER
WALL-MOUNTED SPEAKER
TYPICAL POLE OR BOOM MOUNTED DEVICE NOTATION. EXAMPLE:
WALL-MOUNTED SECURITY CAMERA
POLE-MOUNTED SECURITY CAMERA
AA
S
SYMBOL
SYMBOL
A
B
C
D
A
*
#
SHEET LIST
DRAWING ANNOTATIONS
LEGENDABBRREVIATIONS
ML MONITORED LATCH
MM MULTIMODE FIBER OPTIC CABLE
MREX MOTION REQUEST TO EXIT
MS MONITORED STRIKE
(N) NEW
(NL) NEW LOCATION
NA NOT APPLICABLE
NACLGS NON ACCESSIBLE CEILING SPACE
NC NORMALLY CLOSED CONTACT
NEC NATIONAL ELECTRIC CODE
NO NORMALLY OPEN CONTACT
NS NETWORK SWITCH
NTS NOT TO SCALE
NVR NETWORK VIDEO RECORDER
O OWNER
OB OVERRIDE BUTTON
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
OHM RESISTIVE NETWORK
OPE OWNER PROVIDED EQUIPMENT
OR OPERATING ROOM
ORI OPERATING ROOM INTEGRATION
OSP OUTSIDE PLANT
OXY OXYGEN
PA PUBLIC ADDRESS
PDS PROTECTIVE DISTRIBUTION SYSTEM
POE POWER OVER ETHERNET
PP PATCH PANEL(S)
PR PAIR
PRJ PROJECTOR
PS POWER SUPPLY
PWR POWER
(RL) REMOVE AND RELOCATE
(RE) REMOVE
R RISER
REV REVISION
REX REQUEST TO EXIT SWITCH
RF RADIO FREQUENCY
RFG RAISED FLOOR GROMMET
RI READER INTERFACE
RM ROOM
RMC RIGID METALLIC CONDUIT
RNC RIGID NONMETALLIC CONDUIT
RS-232 TWO WAY SERIAL DATA STREAM
S STATION
SATV SATELLITE TELEVISION
SC SECURITY CONTRACTOR
SCC SECURITY CAMERA
SCHED SCHEDULE
SCNS SECURITY CAMERA NETWORK SWITCH
SCP SECURITY CONTROL PANEL
SCPP SECURITY CAMERA PATCH PANEL
SCPS SECURITY CAMERA POWER SUPPLY
SH SURFACE HOUSING
SM SINGLEMODE FIBER OPTIC CABLE
SMR SURFACE METAL RACEWAY
SMT SURFACE MOUNT
SN SERIAL NETWORK MODULE
SP SURGE PROTECTOR
SPEC SPECIFICATION
SPKR LOUDSPEAKER LEVEL AUDIO
SPR SURFACE PLASTIC RACEWAY
SR SURFACE RACEWAY
SRR SERVER ROOM
STP SHIELDED TWISTED PAIR
SUS SUSPENDED
SV S-VIDEO
TB TERMINATION BLOCK(S)
TBB TELECOMMUNICATIONS BONDING BACKBONE
TBD TO BE DETERMINED
TC TELECOMMUNICATIONS CONTRACTOR
TCP TEMPERATURE CONTROL PANEL
TEL TELEPHONE
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TP TWISTED PAIR
TR TELECOMMUNICATIONS ROOM (IDF, FD)
TYP TYPICAL
U UNIT
UGND UNDERGROUND
UON UNLESS OTHERWISE NOTED
UPP UNSHIELDED TWISTED PAIR PATCH PANEL
UPS UNINTERRUPTIBLE POWER SUPPLY
USB UNIVERSAL SERIAL BUS
UTP UNSHIELDED TWISTED PAIR
VB VOICE BACKBONE
VE VOICE
VGA HD ANALOG VIDEO TYP 15 PIN D-SUB
VGA+A HD ANALOG VIDEO TYP 15 PIN D-SUB & 3.5MM TRS
VGCB VOICE-GRADE COPPER BACKBONE
VLAN VIRTUAL LOCAL AREA NETWORK
VMS VIDEO MANAGEMENT STATION
VOIP VOICE OVER INTERNET PROTOCOL
VSS VIDEO SURVEILLANCE SYSTEM
VTC VIDEO TELE-CONFERENCING
VW VIDEO WALL
W WALL TELEPHONE
WM WALL MOUNTED
WP WEATHER PROOF
WAP WIRELESS ACCESS POINT
AC ABOVE COUNTER
ACEG ALTERNATING CURRENT ELECTRICAL GROUND
ACLGS ACCESSIBLE CEILING SPACE
ACP ACCESS CONTROL PANEL
ACS ACCESS CONTROL SYSTEM
ACT ACOUSTIC CEILING TILE
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AO AUTOMATIC OPERATOR
AOC AUTOMATIC OPENER CONTROLLER
APC ANGLE POLISHED CONNECTOR
APP AUDIO PATCH PANEL
APPROX APPROXIMATELY
AR AUXILIARY RELAY
ARCH ARCHITECT
ATEL ADMINISTRATIVE TELEPHONE
AV AUDIOVISUAL
AVC AUDIOVISUAL CONTRACTOR
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BB BACKBONE
BC BARE COPPER
BEP BUILDING ENTRANCE PROTECTOR
BI BIOMETRIC INTERFACE
BLDG BUILDING
BO BY OTHERS
C CONDUIT
CAB CABINET
CAN CONTROLLED AREA NETWORK
CAT3 CATEGORY 3 COPPER CABLE
CAT5E CATEGORY 5E COPPER CABLE
CAT6 CATEGORY 6 COPPER CABLE
CAT6A CATEGORY 6 AUGMENTED COPPER CABLE
CATV CABLE TELEVISION
CC CONTACT CLOSURE
CCTV CLOSED CIRCUIT TELEVISION
CER CYLINDER ELECTRIC RETRACTION
CLG CEILING
CNL COULD NOT LOCATE
CO CONDUIT ONLY (NO CABLE)
COAX COAX CABLE
COM COMMON
COMM COMMUNICATION
CON CONDUCTOR
CPU COMPUTER PROCESSING UNIT
CPV COMPONENT VIDEO
CR CARD READER
CT COUNT
CV COMPOSITE VIDEO
DB DIRECT BURIAL
(D) DEMOLISH
DD DEAD
DEA DELAYED EGRESS ALARM
DGCB DATA-GRADE COPPER BACKBONE
DIA DIAMETER
DM DIGITAL MULTIMEDIA (SIGNAL)
DP DISPLAYPORT
DPDT DOUBLE POLE DOUBLE THROW
DPS DOOR POSITION SWITCH
DS DIGITAL SIGNAGE
DVI DIGITAL VIDEO INTERFACE
DVR DIGITAL VIDEO RECORDER
DWG DRAWING
(E) EXISTING TO REMAIN
EB EXIT BUTTON
EC ELECTRICAL CONTRACTOR
ECL ELECTRIC CYLINDER LOCK
ECP ELEVATOR CONTROL PANEL
EF ENTRANCE FACILITY (DEMARC)
EIB EMERGENCY INFORMATION BOARD
EL ELECTRIC LATCH
ELEC ELECTRICAL
ELM ELECTRIC LATCH WITH LATCH MONITOR SWITCH
ELR ELECTRICAL LATCH RETRACTION
ELV ELEVATOR
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EQPMT EQUIPMENT
ER EQUIPMENT ROOM
ES ELECTRIC STRIKE
ESO ELECTRICAL SOLENOID
EXIST EXISTING
(F) FUTURE
FAC FIRE ALARM CONTRACTOR
FACP FIRE ALARM CONTROL PANEL
FB FIBER BACKBONE, FLOOR BOX
FD FLOOR DISTRIBUTOR
FL FLUSH
FLEX FLEXIBLE CONDUIT
FPA FLOOR PENETRATION ASSEMBLY
FPD FLAT PANEL DISPLAY
FS FURNITURE SUPPLIER
FSD FIRE STOP DEVICE
G GROUND
GC GENERAL CONTRACTOR
HB HANDICAP BUTTON
HC HORIZONTAL CABLE
HD HIGH DEFINITION
HDBT HDBASET (AV SIGNALS OVER TP)
HDMI HIGH DEFINITION MULTIMEDIA INTERFACE
HO HOLD OPEN
ID INSIDE DIAMETER OR IDENTIFIER
IDS INTRUSION DETECTION SYSTEM
IF INTERFACE PLATE
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IP INTERNET PROTOCOL
IR INFRARED
ISP INSIDE PLANT
IVW IN VARIANCE WITH
IWC IN-BUILDING WIRELESS CONTRACTOR
KIT KITCHEN EQUIPMENT
LAB LABORATORY EQUIPMENT
LC LOW VOLTAGE/SPECIALITY CONTRACTOR
LL LINE LEVEL LEFT CHANNEL AUDIO
LM LINE LEVEL MONO AUDIO
LPS LOCK POWER SUPPLY
LR LINE LEVEL RIGHT CHANNEL AUDIO
MAG MAGNETIC LOCK
MECH MECHANICAL
MED MEDICAL EQUIPMENT
MFR MANUFACTURER
MIC MICROPHONE (CONNECTION)
MIN MINIMUM
ABBREV. DEFINITION ABBREV. DEFINITION
DESCRIPTIONSYMBOL
EQUIPMENT LOCATION
LOUDSPEAKER
FIXED CAMERA
VIDEO DISPLAY
PROJECTION SCREEN
INTERFACE PLATE
PROJECTOR
LECTERN
PAN - TILT - ZOOM CAMERA
AUDIOVISUAL DEVICE
AUDIOVISUAL CEILING DEVICE
AUDIOVISUAL FIELD LOCATED DEVICE
CONTROL PANEL
A E
A
CP
IF
A
A
A
A
A
AUDIOVISUAL
DESCRIPTIONSYMBOL
SECURITY EQUIPMENT LOCATION
ACCESS CONTROL SYSTEM DOOR
(X INDICATES DOOR TYPE)
FIXED CAMERA
PAN - TILT - ZOOM CAMERA
PERSONNEL VERIFICATION DEVICE
SECURITY DEVICE
SECURITY CEILING DEVICE
SYSTEM FIELD LOCATED DEVICE
S E
X
S
S
INTRUSION DETECTION DEVICE
S
S
S
SECURITY
SECURITY WORKSTATION LOCATIONS WDESCRIPTIONSYMBOL
CABLE RUNWAY
CABLE - END LOOP
CABLE - CONTINUOUS LOOP
TELECOM OUTLET
TELECOM OUTLET (CEILING)
COMMUNICATIONS EQUIPMENT LOCATION
COMMUNICATIONS DEVICE
COMMUNICATIONS CEILING DEVICE
COMMUNICATIONS FIELD LOCATED DEVICE
T E
CR
T
T
T
COMMUNICATIONS
DESCRIPTIONSYMBOL
STRUCTURAL BLOCKOUT
CABLE PATHWAY FIRESTOPPING DEVICE
FIRE-RATED FLOOR PENETRATION ASSEMBLY
CABLE SUPPORT PATHWAY
(J-HOOKS / STRAPS / SLINGS)
GROUNDING BUSBAR
GROUND
CONDUIT UNDERGROUND / FLOOR / SLAB
CONDUIT WITH BUSHING
CONDUIT WITH CAP
CONDUIT DOWN
CONDUIT / CABLE HOME RUN
PULL BOX
DEVICE BOX EMPTY (CEILING)
FLOOR BOX
POKE THRU
UTILITY POLE
ENCLOSURE
WALL BOX
CABLE TRAY
SURFACE RACEWAY
MAINTENANCE HOLE
OSP UNDERGROUND DUCTBANK
DEVICE BOX EMPTY
CONDUIT UP
EQUIPMENT RACK
WxH
FSD
FPA
CS
SR
P
U
CT-DxW
E
OSP
COMMON WORK / ELECTRICAL
CLOCK EQUIPMENT LOCATION
CLOCK DEVICE
CLOCK CEILING DEVICE
CLOCK FIELD LOCATED DEVICE
CLOCK
DESCRIPTIONSYMBOL
PUBLIC ADDRESS LOUDSPEAKER
PUBLIC ADDRESS EQUIPMENT LOCATION
PUBLIC ADDRESS DEVICE
PUBLIC ADDRESS CEILING DEVICE
PUBLIC ADDRESS FIELD LOCATED DEVICE
P E
P
C E
P
P
P
C
C
C
SPECIALTY SYSTEMS
IN-BUILDING WIRELESS EQUIPMENT LOCATION
I E
TWO-WAY COMMUNICATION SYSTEM
TC
TECHNOLOGY LEGEND NOTES
#
T00
T10
T30
T31
TECHNOLOGY GENERAL INFORMATION
TECHNOLOGY SITE PLAN
TECHNOLOGY DETAILS
TECHNOLOGY DETAILS
Arvada Office
5420 Ward Road, Suite 200
Arvada, CO 80002
Phone: 303.422.7400
Colorado Springs Office
10807 New Allegiance Drive, Suite 400
Colorado Springs, CO, CO 80921
Phone: 719.533.1112
CONSTRUCTION ADMINISTRATOR
Travis McNair
719.886.2447
RIMROCK CONTACTS
PROJECT MANAGER
Travis McNair
719.886.2447
5570 East Yale AvenueDenver, CO 80222
Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
T00
TECHNOLOGY
GENERAL
INFORMATION
(1) 4 PR COPPER
(1) 6 STRAND MM FIBER
(1) 2-INCH CONDUIT
P
1
1
O
S
P
1
P
1
1
1
O
S
P
OS
P
O
S
P
(1) 6 PR COPPER
(1) 6 STRAND MM FIBER
(1) 2-INCH CONDUIT
5570 East Yale AvenueDenver, CO 80222
Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
T10
TECHNOLOGY
SITE PLAN
5570 East Yale AvenueDenver, CO 80222
Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
T30
TECHNOLOGY
DETAILS
4 11/16 - INCH
SQUARE x
2 1/8 - INCH
DEEP BACK
BOX
CEILING LEVEL
(REF:
ARCHITECTURAL)
WALL
(REF:
ARCHITECTURAL)
FLOOR (REF:
ARCHITECTURAL)
STANDARD
OUTLET HEIGHT
UNLESS
OTHERWISE
NOTED
1 GANG
MUDRING
VERTICAL
CONDUIT TO BEND
WALL FLUSH BACK BOX 1 GANG
INSULATED
THROAT BUSHING
HORIZONTAL
CONDUIT
TERMINATES 2 - INCH
TO 4 - INCH
VERTICALLY ABOVE
AND 2 - INCH
HORIZONTALLY
BEFORE CABLE
RUNWAY
HORIZONTAL CONDUIT TO CABLE RUNWAY FROMCONDUIT STUB AT CABLE RUNWAY
CONDUIT VERTICAL TO HORIZONTAL BEND
BEND RADIUS = MAXIMUM
6 x INTERNAL DIAMETER
VERTICAL CONDUIT TO BACK BOX
HORIZONTAL CONDUIT
TO TERMINATE AT
PULL BOX,
ENCLOSURE, CABLE
RUNWAY OR STUB
INTO ACCESSIBLE
CEILING SPACE
VERTICAL
CONDUIT TO
BACK BOX
BEND ANGLE MEASURED
FROM VERTICAL
THREADED
ROD TO
STRUCTURAL
CEILING
4 11/16 - INCH
SQUARE x
2 1/8 - INCH
DEEP BACK BOX
MUDRING
VERTICAL CONDUIT
TO BEND
FLUSH ACCESSIBLE AND NON-ACCESSIBLECEILING BACK BOX
BEND SHALL BE PROVIDED
TO CREATE OPTIMAL
CONTINUATION OF CONDUIT
AND CABLE TO DESTINATION
DETAIL GENERAL NOTESA.
B.
C.
D.
E.
THESE TYPICAL DETAILS DO NOT COVER EVERY SINGLE TYPE OF INSTALLATION;
HOWEVER THEY PROVIDE GENERAL CONDUIT AND BOX REQUIREMENTS. THE
ELECTRICAL CONTRACTOR SHALL REVIEW ALL OTHER DETAILS FOR MORE SPECIFIC
INSTALLATION REQUIREMENTS INCLUDING, BUT NOT LIMITED TO THE AUDIOVISUAL,
SECURITY AND CAMERA ROUGH-IN DETAILS.
PROVIDE J-HOOK SUPPORTS OR OTHER SPECIFIED CABLE SUPPORT METHOD
WHERE CABLE ROUTING IS NOT INSTALLED IN CONDUIT, CABLE TRAY, OR OTHER
ENCLOSED PATHWAY.
SOME DEVICE BOX TYPES, CONDUIT AND CABLE ROUTING INDICATED MAY NOT
APPLY TO THIS PROJECT. NOT ALL DEVICE BOX TYPES, ASSOCIATED ROUGH-IN, AND
CABLE PATHWAYS FOR THIS PROJECT MAY BE INDICATED.
UNLESS OTHERWISE INDICATED, CONDUIT STUBS SHALL TERMINATE WITH
INSULATED THROAT BUSHING.
NOT ALL ITEMS SHOWN FOR CLARITY.
PROVIDE
SURFACE MOUNT
HOUSING
4 - INCH
MINIMUM
CLEARANCE
BETWEEN BOX
AND CEILING
CEILING GRID
(REF: ARCHITECTURAL)
COVER
ABOVE ACCESSIBLE CEILING BACK BOX
CEILING GRID
(REF: ARCHITECTURAL)
CABLE TO DEVICE CONDUIT STUB
ABOVE ACCESSIBLE CEILING
J-HOOK/STRAP TYPE
SUPPORT MAY BE HUNG
FROM CEILING AND/OR
WALL MOUNTED
SPACE CONSECUTIVE J-HOOKS
/ STRAPS AS SPECIFIED
ELSEWHERE IN DOCUMENTS
CABLE TO CABLE RUNWAY FROM CONDUIT STUBABOVE ACCESSIBLE CEILING
THREADED
ROD
TO STRUCTURAL
CEILING
TO STRUCTURAL
CEILING
"TRAPEZE" TYPE
SUPPORT
BRACKET
CABLE PATHWAY SHOWN FOR
ILLUSTRATION ONLY. SEE
SPECIFICATIONS FOR ACTUAL
PATHWAY REQUIREMENTS
HORIZONTAL CONDUIT STUB 6 - INCH
MINIMUM ABOVE ACCESSIBLE CEILING
APPROX. 12 - INCH TO
FIRST J-HOOK IN
SERIES
SPACE CONSECUTIVE J-
HOOKS AS SPECIFIED
ELSEWHERE IN DOCUMENTS
HORIZONTAL CONDUIT STUB ABOVEACCESSIBLE CEILING
1 - INCH CONDUIT
VERTICAL CONDUIT TO BACK BOX
INSULATED THROAT BUSHING
J-HOOK SUPPORT
MAY BE HUNG FROM
CEILING AND/OR THE
WALL MOUNTED.
CABLES CONTINUE TO FINAL DESTINATION
VERTICAL CONDUIT
TO BEND
THREADED
ROD TO
STRUCTURAL
CEILING
THREADED
ROD
TO STRUCTURAL
CEILING
TO STRUCTURAL
CEILING
"TRAPEZE" TYPE
SUPPORT
BRACKET
CABLE PATHWAY SHOWN FOR
ILLUSTRATION ONLY. SEE
SPECIFICATIONS FOR ACTUAL
PATHWAY REQUIREMENTS
1 - INCH
CONDUIT
1 - INCH CONDUIT
4 11/16 - INCH
SQUARE x
2 1/8 - INCH DEEP
BACK BOX
1 - INCH CONDUIT
1 - INCH CONDUIT
1 - INCH CONDUIT
STANDARD
OUTLET HEIGHT
UNLESS
OTHERWISE
NOTED
WALL FLUSH BACK BOX 2 GANG
4 11/16 - INCH
SQUARE x
2 1/8 - INCH
DEEP BACK
BOX
CEILING LEVEL
(REF:
ARCHITECTURAL)
WALL
(REF:
ARCHITECTURAL)
FLOOR (REF:
ARCHITECTURAL)
2 GANG
MUDRING
VERTICAL
CONDUIT TO BEND
1 - INCH CONDUIT
TE-CRSCALE: NONE
TYPICAL DEVICE ROUGH-IN AND CABLE PATHWAY DETAIL
TO
TELECOM
ROOM
TO
DEVICE
BOX
SPACE CONSECUTIVE
J-HOOKS PER
SPECIFICATIONS
J-HOOK PATHWAY
J-HOOK TYPE SUPPORT
J-HOOK SUPPORT MAY
BE HUNG FROM
CEILING AND/OR WALL
MOUNTED. SEE
SPECIFICATIONS
TE-JHSCALE: NONE
TYPICAL CABLE J-HOOK PATHWAY
TO
TELECOM
ROOM
TO
DEVICE
BOX
LOOP STRAP SUPPORT
MAY BE HUNG FROM
CEILING AND/OR WALL
MOUNTED. SEE
SPECIFICATIONS
SPACE
CONSECUTIVE
LOOP STRAPS PER
SPECIFICATIONS
LOOP STRAP PATHWAY
STRAP TYPE SUPPORT
TE-CSSCALE: NONE
TYPICAL CABLE SUPPORT STRAP PATHWAY
5570 East Yale AvenueDenver, CO 80222
Phone: 303-681-2846
MELLIN & ASSOCIATES
ARCHITECTS, P.C.
BCER ENGINEERING:
BCER RIMROCK TECHNOLOGY:
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Chris Wren
10807 New Allegiance Dr.,Suite 400
Colorado Springs, Co. 80921719-533-1112
Contact: Travis McNair
T31
TECHNOLOGY
DETAILS
ROUTE CONDUIT TO ACCESSIBLE CEILING SPACE
ON SECURED SIDE TO CONSOLIDATION BOX OR
REMOTE ACCESS CONTROL PANEL
CR
TYPICAL LAYOUT OF DEVICES ASSOCIATED TO ACCESSCONTROLLED DOORS
VIEWED FROM SECURED SIDE
HINGE
SIDE
VIEWED FROM SECURED SIDE
HINGE SIDE
EBHB
UNSECURED
SIDE
1 GANG DEVICE
MOUNTING
NOTE:
CR
TYPICAL LAYOUT OF DEVICES ASSOCIATED TO ACCESSCONTROLLED DOORS
DR DRHB
TYPICAL OF DOOR CONDUIT,
SIZE AND QUANTITY VARY
HB
CR
BOLLARD ON
UNSECURED
SIDE
3/4-INCH
CONDUIT
(TYP)
HB EB
TYPICAL OF DOOR CONDUIT,
SIZE AND QUANTITY VARY
THIS DETAIL DEPICTS COMMON DEVICES ASSOCIATED WITH ACCESS CONTROLLED DOORS. NOT ALL
DEVICES SHOWN ARE NECESSARY FOR INSTALLATION.
A.
HB
CR KS CRHB
NOTE:
THIS DETAIL DEPICTS COMMON DEVICES ASSOCIATED WITH ACCESS CONTROLLED DOORS. NOT ALL
DEVICES SHOWN ARE NECESSARY FOR INSTALLATION.
A.
ALIGN HEIGHTS
HINGE
SIDE
FLOOR
CEILING
FLOOR
CEILING
CRKS
ALIGN HEIGHTS
PS
UNSECURED
SIDE
4 x 4 - INCH DEVICE
BOX WITH 1-GANG
MUD RING (TYP)
ROUTE CONDUIT TO ACCESSIBLE CEILING SPACE ON
SECURED SIDE TO CONSOLIDATION BOX OR REMOTE ACCESS
CONTROL PANEL
PS
3/4-INCH
CONDUIT
(TYP)
DOOR FRAME
VIEWED FROM SECURED SIDE
CONSOLIDATION BOX OR
REMOTE ACCESS
CONTROL PANEL
MOUNTED ON SECURED
SIDE OF DOOR
TYPICAL ACCESS CONTROL SYSTEM SINGLE LEAF DOOR
MREX
4 x 4 - INCH DEVICE BOX WITH
1-GANG MUD RING MOUNTED
HORIZONTALLY
PATHWAY WITHIN
DOOR
DPS MAG
LOCK / PANIC
FLOOR
CEILING
ES
3/4-INCH
CONDUIT (TYP)
X
DOOR FRAME
VIEWED FROM SECURED SIDE
LEAF 1 LEAF 2
TYPICAL ACCESS CONTROL SYSTEM DOUBLE LEAF DOOR
MAG
MREX
4 x 4 - INCH DEVICE BOX WITH
1-GANG MUD RING MOUNTED
HORIZONTALLY
PATHWAY WITHIN DOOR
(TYPICAL)
DPS MAGDPS
FLOOR
CEILING
ES
NOTE:
ELECTRIC STRIKE: IF A MULLION IS SPECIFIED, THEN THE ELECTRIC STRIKE AND CONDUIT FEED
MOUNT WITHIN MULLION.
1.
LOCK / PANICES
LOCK / PANIC XX
MULLION (IF APPLICABLE)
3/4-INCH
CONDUIT (TYP)
VIEWED FROM SECURED SIDE
OVERHEAD
SENSOR
JUNCTION BOX
SENSOR
CR
OPENER
TYPICAL ACCESS CONTROL SYSTEM OVERHEAD DOOR
FLOOR
CEILING
DPS
OCCUPANCY SENSOR
(BY OTHERS)
ARMORED
CABLE
OVERHEAD
DOOR
OVERHEAD DOOR
OPENER (BY OTHERS)
CR
ROUTE CONDUIT TO ACCESSIBLE CEILING SPACE ON
SECURED SIDE TO CONSOLIDATION BOX OR REMOTE
ACCESS CONTROL PANEL
3/4-INCH IN WALL
CONDUIT (TYP)
UNSECURED SIDE
ELEVATOR
DOORS
VIEWED FROM LOBBY SIDE
TYPICAL ACCESS CONTROL SYSTEM ELEVATOR
SECURITY CONTRACTOR SHALL COORDINATE WITH ELEVATOR CONTRACTOR FOR CARD READER
LOCATION AND INSTALLATION REQUIREMENTS.
A.
NOTES:
CR
CONNECT TO TRAVEL
CABEL IN CONSOLIDATION
BOX OR ELEVATOR
CONTROL PANEL
ELEVATOR
TRAVEL CABLE,
BY ELEVATOR
CONTRACTOR
ELEVATOR
CAB
CARD READER
(INSIDE CAB)
FLOOR
CEILING
TRANSFER HINGE
(TYPICAL)
CONSOLIDATION BOX OR
REMOTE ACCESS
CONTROL PANEL
MOUNTED ON SECURED
SIDE OF DOOR
TRANSFER HINGE
(TYPICAL)
A.
B.
C.
D.
E.
F.
G.
H.
REFER TO T-MH FOR DEVICE MOUNTING HEIGHT DETAILS.
REFER TO TS-DPS FOR DOOR POSITION SWITCH MOUNTING
DETAILS.
REFER TO TS-SRD FOR DEVICE MOUNTING DETAILS.
DATA CONDUIT: REFER TO TELECOM / DATA REQUIREMENTS FOR
CONTINUATION OF CONDUIT.
DEVICE MOUNTING: PROVIDE DEVICE MOUNTING REQUIREMENTS
PER MANUFACTURER RECOMMENDATIONS.
CABLE ROUTING: REFER TO ONE-LINE DIAGRAMS FOR CABLE
ROUTING REQUIREMENTS.
DEVICE BOX AND ENCLOSURE MOUNTING: PROVIDE SECURED
MOUNTING SUPPORT PER MOUNTING
REQUIREMENTS INDICATED WITHIN ELECTRICAL DOCUMENTS.
ALL CONDUITS CONCEALED IN WALL WHEN BELOW CEILING.
DETAIL GENERAL NOTESCR
ROUTE CONDUIT TO
CONSOLIDATION BOX OR
ELEVATOR CONTROL PANEL IN
ELEVATOR MACHINE ROOM
3/4-INCH
CONDUIT (TYP)
CARD READER
(OUTSIDE CAB)
1 GANG DEVICE
MOUNTING
BOLLARD ON
UNSECURED
SIDE
XTS-DDSCALE: NONE
DOOR DETAILS
X